Post on 06-Apr-2020
transcript
Order code: LEDJ187
100W UV COB Flood User Manual
www.prolight.co.uk 100W UV COB Flood User Manual 2
Safety advice
WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.
OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS
CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoflammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageisbetween100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.
• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.
• Thislightingfixtureisforprofessionaluseonly-itisnotdesignedfororsuitableforhouseholduse.Theproductmustbeinstalledbyaqualifiedtechnicianinaccordancewithlocalterritoryregulations.Thesafetyoftheinstallationistheresponsibilityoftheinstaller.Thefixturepresentsrisksofsevereinjuryordeathduetofirehazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingtoEN62471.Donotviewthelightoutputwithopticalinstrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Oneyearfromdateofpurchase.
www.prolight.co.uk 100W UV COB Flood User Manual 3
Product overview & technical specifications
FeaturingCOBtechnologythisrobustfloodisloadedwitha100WUVLEDwhichishousedina80°reflectorandsuppliedwiththreebeamreductionlenses(25°,40°and50°).ThisfixturehasbeendesignedtofillavarietyofvenueswithanoutstandingUVglowandiseasytotransportandinstall.ThehighoutputLEDisidealforwashingstages,nightclubs,bowlingcentresandskatingrinks.
100W UV COB Flood
257mm 245mm
310mm
•1x100WUVCOBLED
•Beamangle:80°native,25°,40°and50°beamreductionlensessupplied
•Ultravioletwavelength:400nm
•1.1kHzrefreshrate
•DMXchannels:1or2selectable
•Staticandsoundactivemodes
•0-100%dimmingandvariablestrobe
•Bracketallowsformultipleriggingandfloorstandingapplications
•4pushbuttonmenuwithLEDdisplay
•PowerCONinput/output
•3-PinXLRinput/output
•Fancooled
Specifications 100W UV COB Flood
Powerconsumption 105W
Powersupply 100~240V,50/60Hz
Fuse T2A250V
Dimensions 310x257x245mm
Weight 3.6kg
Ordercode LEDJ187
www.prolight.co.uk 100W UV COB Flood User Manual 4
Technical specifications
01-Earthpoint
02-Safetyeye
03-LEDdisplay
04-Functionbuttons
05-3-PinDMXinput
06-3-PinDMXoutput
07-PowerCONinput
08-PowerCONoutput
09-FuseT2A250V
10-Hangingbracket
11-Hangingbracketadjustableknob
Inthebox:1 x fixture, 1 x 25° beam reduction lens, 1 x 40° beam reduction lens, 1 x 50° beam reduction lens, 1 x power cable & 1 x user manual
100W UV COB Flood
MENU
DMX INPUT
POWER INPUT:100-240V~50/60Hz
FUSE:T2A 250V
POWER OUTPUT:100-240V~50/60Hz
DMX OUTPUT
UPENTER DOWN
www.prolight.co.uk
10
05
11
07
0901 02
04
03
11
10
06
08
www.prolight.co.uk 100W UV COB Flood User Manual 5
Operating instructions
MENU
S L A u Slave mode
d o n
d o n
d o F FDisplay backlight
S t n d
rEv Display inverse
d E F A Reset factory settings
S J - 1
S J - 8
Sound active/sound sensitivityS J - 5
U. 0 0 0
U. 2 5 5
F 5. 0 0
F 5. 1 5
Manual dimming modeU. 2 5 5
d. 0 0 1
d. 5 1 2
C h 0 1
C h 0 2
DMX address/channel settingd. 0 0 1
www.prolight.co.uk 100W UV COB Flood User Manual 6
DMX mode:
OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestflexibilitywhenitcomestocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthefixtureandeachfixtureindependently.
ToaccesstheDMXaddressmode,pressthe“MENU”buttonontherearoftheunittoshowd.001ontheLEDdisplay.Nowusethe“UP”and“DOWN”buttonstosettherequiredDMXaddress.Pressthe“ENTER”buttontoconfirmthesetting. TheDMXchannelmodewillnowbedisplayed,usethe“UP”and“DOWN”buttonsontherearoftheunittoselecteither1or2DMXchannelmode.Pressthe“ENTER”buttontoconfirmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Master/slave mode:
Tosetthemasterunit,pressthe“MENU”buttonontherearofthemasterunitthenselectyourdesiredprogram(soundactiveordimmermodes).Tosettheotherunitsinslavemode,pressthe“MENU”buttonontherearoftheunittoshowSLAuontheLEDdisplayandpressthe“ENTER”buttontocon-firmthesetting.Theunitswillnowruninsequencewiththemasterunit.Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.
Manual dimming mode:
Toaccessthemanualdimmingmode,pressthe“MENU”buttonuntilthedisplayshowsU.255ontheLEDdisplay.Usethe“UP”and“DOWN”buttonstoselecttherequiredbrightnessfromU.000~U.255.Toadjusttheflashspeedpressthe“ENTER” buttonandthenusethe“UP”and“DOWN”but-tonstoselectanyvaluefromF5.00~F5.15.Pressthe“ENTER” buttontoconfirmthesetting.
Value: 000 - 255 (000 = low brightness, 255 = high brightness) Value: 00 - 15 (00 = no flash, 15 = fast flash speed)
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Operating instructions
Channel Value Function
1 000-255 Masterdimmer(0-100%)
2 000-015 Nofunction
016-255 Strobe(slow-fast)
2 channel mode:
Channel Value Function
1 000-255 Masterdimmer(0-100%)
1 channel mode:
www.prolight.co.uk 100W UV COB Flood User Manual 7
Operating instructions
Sound active:
Toaccessthesoundactivemode,pressthe“MENU”buttonuntilthedisplayshowsSJ-5ontheLEDdisplay.Usethe“UP”and“DOWN”buttonstoselecttherequiredsoundsensitivityfromSJ-1~SJ-8.Pressthe“ENTER” buttontoconfirmthesetting.
Value: 1 - 8 (1 = low sensitivity, 8 = high sensitivity)
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Display backlight:
Toaccessthedisplaybacklightsetting,pressthe“MENU”buttonuntilthedisplayshowsdonontheLEDdisplay.Usethe“UP”and“DOWN”buttonstoselecteitherdon(displaybacklighton)~doff(displaybacklightoff).Pressthe“ENTER” buttontoconfirmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Display inverse:
Toaccessthedisplayinversesetting,pressthe“MENU”buttonuntilthedisplayshowsdonontheLEDdisplay.Pressthe“ENTER” buttontodisplayStndandusethe“UP”and“DOWN”buttonstoselecteitherStnd(displaystandard)~ (displayinverse).Pressthe“ENTER” buttontoconfirmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Reset factory settings:
Toresetthefactorysettings,pressthe“MENU”buttonuntilthedisplayshowsdonontheLEDdisplay.Pressthe“ENTER” buttontwicetodisplaydEFa.Pressthe“UP”and“DOWN”buttonstogetherandthefixturewillberesettoitsfactorysettings.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.rEv
www.prolight.co.uk 100W UV COB Flood User Manual 8
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-511.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:
CABL10 – 2mCABL11 – 5mCABL12 – 10m
www.prolight.co.uk 100W UV COB Flood User Manual 9
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmissionproblemsandinterference.ItisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.
5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C
3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)
3-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)
5-pin XLR (socket)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C
DMX setup
www.prolight.co.uk 100W UV COB Flood User Manual 10
WEEE notice
Correct Disposal of this Product (Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
www.prolight.co.uk 100W UV COB Flood User Manual 11
www.prolight.co.uk 100W UV COB Flood User Manual 12