Post on 26-Mar-2015
transcript
11Michael Bank E-mail: bankmichael1@gmail.com
There are some articles in site: www. OFDMA-Manfred.com
Two faces Janus
The Israel Museum, Jerusalem
One face is better
Museum visitor
One-Way Electric Line(B-Line)
2
Content : Slides
Introduction 3Part 1. Main idea 8Part 2. Low (50 Hz) Frequency B-Line 10Part 3 The first B-line experiments 43Part 4. Power loses and interferences 48Part 5. High-Frequency One-Wire Line 62Part 6. Using B-Line in antenna construction 68Part 7. B-Line for DC 71Part 8. Expectations, dreams, hopes 72 Conclusion 79
“Transmission of electricity requires at least two wires” - this statement has been ingrained in the consciousness of engineers for over 150 years.
http://en.wikipedia.org/wiki/Transmission_line
This is two-way system
3
Part 1. Introduction
Fiber Optic Systems
4
One Way System Examples
Waveguide
Radio Systems
Can a one-wire method also be used in any electrical system for transmission of energy or information?
5
Mechanical Telegraph
Energy is transferred in one direction from the source to the load and does not return. Why do we need two channels? 6
One line mechanical system
7
Earlier Attempts
•Single-wire electrical energy transmission by Nikola Tesla (1890) [US Patent number 1,119,736)
• The Goubau line, a single-wire transmission line at microwave frequencies. (Geog Goubau, "Surface waves and their Application to Transmission Lines," Journal of Applied Physics 21 (1950))
• AFEP experiment based on the Russian patent application (1993 ) by Stanislav and Konstantin Avramenko (PCT/GB93/00960 ).
These methods all lead to loss of energy and a change in the signal waveform.
• Known single-wire system SWER transmits only half the source energy
8
In this two line system (A-Line), the currents in each wire are in opposite phases.
Part 1. Main idea
One-Way Electric Line Model
• The source (generator) produces two signals of opposite phases
• The current will flow through the load with opposite phases as well.
B-Line: Wires with the same (equipotential) currents can be combined.
G RL
Inv Inv
Main Idea: With the inverters, we can get the same potential polarity in both wires
9
10
Part 2. Low (50 Hz) Frequency B-Line
That's one of the simulations for the verification of Ohm's law in the proposed scheme. In this known A-Line circuit current amplitude everywhere should be 90 A. 1 kOhm is the lines resistance.
In the proposed B-Line scheme, we added inverters at the input and output, and combined the two lines. As a result a line resistance is 0.5kOhm. The simulation shows that the currents at the input and output have not changed. The polarity of the load current depends on where the inverter is at the top or bottom.
2.1 Basic simulations
1111
B-Line with two delay lines ADS simulation
This position of probe shows positive current direction.
12
+ -
1 V1 kOhm
Probe 1
A-line scheme
B-Line with two transformers ADS simulation
A-line simulation example
13
B-line simulation
The delay line of half a period at a frequency of 50 Hz has a length of 3000 km. Therefore, this type of inverter can be used only in simulations.Here one can see results of simulations real scheme, where inverter build by transformers with opposite windings (onwards Tr-Inv).
2
3
4
1
2
3
4
1B-Line
After two filters
After inverter for phase 3
It is possible converting B-Line to three phase signal by two filters and inverter
The same circuit, but in reverse sequence converts three phase signal to B-Line
Three identical B-Lines
2.2 Single Wire Three-Phase System
Scheme with additional inverter T6 for receiving phase difference +/- 1200.
2
3
4
1
2
3
4
1
One wire to three phase scheme
1
24
3
1
We reached a three-phase voltage.
Three phase scheme simulation results
17
2.3 About ground using
So we to provide required Tr-Inv we use the transformer with opposite windings. And we have to turn it into one wire (lower one on the picture).
It is therefore logical to apply zeroing at the lower point. Now through each winding its own current will flow only.
Current. which follows from the secondary winding is equal to the current flowing in the primary winding.
You can not turn it on, since no current will flow through the windings.
The ground is needed, that would be current flowed in the windings. It flows into the ground and spreads out in an endless ground, as is the case with a protective earth.
18
In the case of protective grounding, if an accident happens, the current anywhere in the other place does not get.
Wikipedia: In electronic circuit theory, a "ground" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid.
The main characteristic of the grounding resistance is spreading current, i.e., a resistance that the earth (ground) has a current spreading at the site of this current. Land spreading is a ground area that surrounds the grounding electrodes, in which the boundary of the current density is so low that potential, which has virtually no land depends on the current flowing from the electrodes. That is why outside of this boundary current can always be equated to zero.
http://expert-montag.ru/article/zashhitnoe_zazemlenie.html
Current spreads in the earth in all directions and therefore countless ground resistance is zero.If we carry the current in a wire connected to ground, the wire current flows, but in the ground it will not be (if grounding ideal) because the potential at the connection point all the time is zero.
19
In the proposed B-Line scheme, the current of the A-Line second line does not go into the ground. It flows into the first line after inverting the phase.Taking into account importance of this issue, we give here four proofs of the fact that ground does not participate in signal transduction in the proposed system. Although one proof (any) would be sufficient
Proof 1. Return to the B-Line simulation. In accordance with Ohm's law, in a case of the source with a voltage of 1 volt and 1kOhm load, the current is equal to 1mA. This is exactly the obtained in the simulation. If some other current flowed into earth, the current in the lines would be lower. The result of simulation shows that there is no other current except the current in lines.
20
Proof 2. If one part of the scheme (transmitting or receiving) do with the delay line, the circuit works properly and gives exactly the same load current. Obviously, in this case there is no connection to the ground.
Proof 3. One opponents objection against the single-wire method is as follows. In the scheme, where the inverters in the form of transformers, there is current in the transmitting part, which goes into the ground.But if in the simulation with a long B-Line of we replace ground on the trunk, the scheme does not work.
TranTran1
MaxTimeStep=1 msecStopTime=6.04 sec
TRANSIENT
TimeDelayTD3
ZRef=5 OhmDelay=10 msec
I_ProbeI_Probe1
I_ProbeI_Probe3
I_ProbeI_Probe2
TFTF2T=1.00
VtSineSRC2
Phase=0Damping=0Delay=0 nsecFreq=50 HzAmplitude=1 VVdc=0 V
RR2R=50 Ohm
TFTF6T=1.00
Probe 1Probe 2
Probe 3
Probe1
Probe 2 Probe 3
A A A
1 V 50 Ohm
21
Gen
+ -
+ -
Proof 4. The current in the transmitting part, which requires a zeroing has polarity corresponds to polarity of the common wire, that is coincident with the polarity of the applied voltage. (Zero potential is possible to get not only with the help of ground, but with the compensation current by current with opposite polarity.Suppose we want to transmit energy in various places. Then it can be in two different lines apply signals of opposite polarity. If you connect the dots require a zeroing of both schemes, the ground connections are not required.
22
23
In fact, in the case of ideal protective ground the entire current is absorbed without any reflection or without reaching any other load.
It is reminiscent of the absorption of the light beam by perfectly black surface
0J
I = 0
No reflections
No light
Ideal ground is actually absorption, similar to the absorption of light by perfect blackbody
Absorbable current
I_ProbeI_Probe4
I_ProbeI_Probe2
I_ProbeI_Probe1
I_ProbeI_Probe3
TranTran3
MaxTimeStep=1 msecStopTime=6.07 sec
TRANSIENT
TFTF7T=1.0
RR1R=1 kOhm
TFTF8T=1.0
VtSineSRC1
Phase=0Damping=0Delay=0 nsecFreq=50 HzAmplitude=1 VVdc=0 V
JJ
- 2 J
2 J
1:1
1:1
2 J
Absorbable current is equal to the current in the common wire
24
TFTF10T=100.0
TranTran3
MaxTimeStep=1 msecStopTime=6.07 sec
TRANSIENT
TFTF9T=0.01
TFTF8T=1.0
RR1R=1 kOhm
TFTF7T=1.0
VtSineSRC1
Phase=0Damping=0Delay=0 nsecFreq=50 HzAmplitude=1 VVdc=0 V
J
- 0.02 J
2 J
- J
0.02 J 0.02 J- 2 J
2.02 J
- 2 J
2.02 J
1:1
1:1
1:100 100:1
Absorbable current is greatly reduced if the line voltage is increased
25
TimeDelayTD3
ZRef=5 OhmDelay=10 msec
I_ProbeI_Probe3
I_ProbeI_Probe2I_Probe
I_Probe1
RR1R=50 Ohm
TranTran1
MaxTimeStep=1 msecStopTime=1.4 sec
TRANSIENT
TFTF2T=1.00
VtSineSRC1
Phase=0Damping=0Delay=0 nsecFreq=50 HzAmplitude=1 VVdc=0 V
TFTF14T=1.00
20 mA20 mA 40 mA
20 mWt
20 mWt
2.4 May be is it possible to dispense with the inverter in receiving part?
Basis B-Line
26
I_ProbeI_Probe2I_Probe
I_Probe1
RR1R=50 Ohm
TranTran1
MaxTimeStep=1 msecStopTime=1.4 sec
TRANSIENT
TFTF2T=1.00
VtSineSRC1
Phase=0Damping=0Delay=0 nsecFreq=50 HzAmplitude=1 VVdc=0 V
TFTF14T=1.00
5 mA 10 mA
5 mWt5 mWt
1 V
B-Line without second invertor
Load power decreased by 4 times. But 4 times decreased power feed source too.
27
28
+/- V/2
-/+ V/2
V
+/- V/2
-/+ V/2
V=
+/- V/2
Explanation of the reducing process of the received and given powers.
This not only reduces the voltage, but also resistance. Obviously, the use of transformer 1 : 2 does not lead to losses.
TFTF14T=0.5
VtSineSRC1
Phase=0Damping=0Delay=0 nsecFreq=50 HzAmplitude=1 VVdc=0 V
I_ProbeI_Probe2I_Probe
I_Probe1
RR1R=50 Ohm
TranTran1
MaxTimeStep=1 msecStopTime=1.4 sec
TRANSIENT
TFTF2T=1.00
20 mA20 mA20 mWt
20 mWt
1 V1 : 2
Basis without second invertor and with first transformer 1 : 2
Yes, you can do without a second inverter.To provide power for appliances can apply one wire and earth. However, the need to apply twice the voltage.
29
30
This simulation shows that even in case of a large number of consumers, there is no danger of a strong input current into the ground when house flats are equipped with a single-wire system.
2.5 Absorbable current minimizationIf the building is supplied by two-wire cable, for example as single-phase of three-phase system, in the ground does not current flows. The results of simulations confirm this.
31P = 1 * 0.125 = 0.125mW P = 2[(0.25mA)2 * 1000 ] = 0. 125 mW
Input power Output power
If the object is connected to the single-wire line. Than can divide object into two parts, and supply it by the signals of different polarity. Then, under the same load, currents reaching the ground will be compensated. In this simulation resistances 1 kOhm is half objects parallel loads.
- 0.25 mA
+ 0. 25 mA
Object
TranTran2
MaxTimeStep=1 msecStopTime=2.1 sec
TRANSIENT
I_ProbeI_Probe3
I_ProbeI_Probe6
VtSineSRC4
Phase=0Damping=0Delay=0 nsecFreq=50 HzAmplitude=1 VVdc=0 V
I_ProbeI_Probe1
I_ProbeI_Probe4
RR14R=1 kOhm
TFTF3T=1.00
TFTF2T=1.00 I_Probe
I_Probe5
I_ProbeI_Probe2
RR16R=1 kOhm
+ 0.125 mA
+ 0.25 mA
- 0. 25 mA
+ 0. 25 mA
Transformer vault
32
grounding Single-wire distribution
Single-wire distribution
Absorbable current in building minimization
Two B-Lines
The use of protection grounding to reset the transformer is not a means of communication between the source and
the load
If the power goes out a few lines, the currents in the ground point can be compensated by an appropriate choice of the polarity signal.
Very only approximate figures. The transmitted power of 1 GW. Voltage 1000 kVSo current can be 1000A. Or resistance 1000000/1000 = 1000 ohmsGround impedance 4 ohms. delta-grup.ru/bibliot/97/89/htm
20 mR = 4 Ohm
20 mR = 4 Ohm
0.1 1 kOhm/m
Absorption space
34
2.6 Know-how – without inverters and grounding
It is possible to make 50 Hz source without grounding using. It offers single-pole source (generator) and a single-pole signal receiver (e.g. motor). They can connect one wire without the use of inverters and therefore no ground (no zeroing)..
Actually output stage of popular operational amplifiers is single pole source
OA 741
35
502 504 506 508500 510
-40
-20
0
20
40
-60
60
time, usec
I_P
robe
1.i,
uA
RR6R=0.1 kOhm
CC1C=1.0 nF
OpAmpAMP1
VCC=15 VVEE=-15 VZero1=Pole1=BW=1 MHzVOS=0 VIOS=0 ASlewRate=1e+6CCom=0 FRCom=1 MOhmCDiff=0 FRDiff=1 MOhmRout=10 OhmCMR=Gain=100 dB
RR2R=10 kOhm
RR9R=0.1 kOhm
VtSineSRC2
Phase=0Damping=0Delay=0 nsecFreq=0.5 MHzAmplitude=1 VVdc=0 V
TranTran1
MaxTimeStep=0.1 usecStopTime=510 usec
TRANSIENT
I_ProbeI_Probe1
Actually this is B-line too
36
502 504 506 508500 510
-50
0
50
-100
100
time, usec
I_P
robe
1.i,
uA
TimeDelayTD3
ZRef=5 OhmDelay=1 usec
RR6R=0.1 kOhm
CC1C=1.0 nF
OpAmpAMP1
VCC=15 VVEE=-15 VZero1=Pole1=BW=1 MHzVOS=0 VIOS=0 ASlewRate=1e+6CCom=0 FRCom=1 MOhmCDiff=0 FRDiff=1 MOhmRout=10 OhmCMR=Gain=100 dB
RR2R=10 kOhm
RR9R=0.1 kOhm
VtSineSRC2
Phase=0Damping=0Delay=0 nsecFreq=0.5 MHzAmplitude=1 VVdc=0 V
TranTran1
MaxTimeStep=0.1 usecStopTime=510 usec
TRANSIENT
I_ProbeI_Probe1
This is more efficiency B-line
37
The proposed B-Line (single-wire) system is often compared to SWER system. As usual SWER one translate like:Electricity distribution method using only one conductor with the return path through earth.
But this system should be called:Transmission system over a single wire, where ground is used instead of the second wire and where the distance between the source and the load is large, so that the resistance on the ground between them is much greater than the resistance of the wire.
The ground in SWER (after generator and before load) makes zeroing. That is, the current in a conductor connected to the ground, anyone in the other place does not receives this current.
http://en.wikipedia.org/wiki/Ground_(electricity) : An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a "ground" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential.
2.7 SWER system
38
There is much literature on the issues of SWER (www.ruralpower.org ). Everywhere it is written about the obvious advantages.Typically, such a scheme is given.
The following simulations show that in the system from the top half of the power is lost.Current flowing from point X misses the load, located far away from the source. Ground resistance is incomparably greater than the resistance wire.
X
39
According to the SWER authors the grounding resistance is 1 Ohm
TimeDelayTD4
ZRef=5 OhmDelay=0.5 msec
TimeDelayTD3
ZRef=5 OhmDelay=0.5 msec
TranTran1
MaxTimeStep=1 msecStopTime=1.04 sec
TRANSIENT
TFTF2T=1.0
TFTF1T=1.0
I_ProbeI_Probe3
I_ProbeI_Probe2
I_ProbeI_Probe1
VtSineSRC1
Phase=0Damping=0Delay=0 nsecFreq=50 HzAmplitude=1 VVdc=0 V
RR1R=50 Ohm
150 kmTwo line system
Simulation of common two line and SWER systems
Probe1 25mA Probe2 25 mA Probe3 20 mA 40
TimeDelayTD3
ZRef=5 OhmDelay=0.5 msec
TranTran1
MaxTimeStep=1 msecStopTime=1.04 sec
TRANSIENT
TFTF2T=1.0
TFTF1T=1.0
I_ProbeI_Probe3
I_ProbeI_Probe2
I_ProbeI_Probe1
VtSineSRC1
Phase=0Damping=0Delay=0 nsecFreq=50 HzAmplitude=1 VVdc=0 V
RR1R=50 Ohm
150 kmSWER
Probe1 40 mA Probe2 40 mA Probe3 20 mA
40 mWt
20 mWt
41
Conclusion: In both systems SWER and B-Line (one wire) the current in common wire is the same and equals to twice the current in the load.But in the scheme of SWER current in the generator is also doubled, and in B-Line it is equal to the current in the load.
Inv.
I 2I
SWER B-Line
The difference between SWER and B-Line
I I
42
4343The experiments confirmed the results of simulations.
Part 3. The first B-line experiments
44
Model was constructed to test the possible influence of the neutral conductor of three-phase system (photo in next slide)
Resistance of the primary windings of transformers is approximately 400 Ohm. The output voltage was equal to the calculated value.
At the entrance isolation transformer is applied to avoid possible grounding system through the neutral wire three-phase network.
45
All currents and voltages in this model correspond to simulation.
46
Experiment B-Line in JCT
In addition to conducting simulations and experiments, it was decided to make an experimental line between two buildings JCT.The transmitting part (source) is housed in building Beren. The first receiver (light bulb 60 W) is located in another building. The second receiver (same bulb) is located in the same building (Beren), but in different room.These earth buildings are different. The wires between the source and receivers 200m long.220 V voltage is supplied to source by a two-pin plug. Source has two single-ended output. The source is not connected to earth.
200 m
200 m
House 2
JCT experiment B-Line scheme
House 1
47
4848
B-line system uses instead of two wires of A-line system one wire only. But one wire in B-Line and two wires in A-Line mast have the same resistance. Maybe three phase system gives advantage on cupper sawing? Let us compare.
It is well known fact, that the main advantage of the three-phase system, compared to the one-phase system, is that the same power can be transmitted by using only three wires instead of six wires, saving twice the amount of material and losses.
But in three phase system line voltage is: VLin = 3V . It does not influence a power, because it is known that power of three phase system equals 3Vlin*I .However this fact needs another comparison. In the two line system voltage can be increased by 3 with transformer. In this case the current decreases by the same3 and power does not change.But in three phase system voltage increases without current decreasing and its losses comparing to two wire system are greater.Despite on the advantages of three line system its behavior looks like a bad transformer (the voltages increase but a current does not drop down)
Part 4. Power loses and interferences 4.1 One wire instead 2 or 4
4949
Comparison of losses in the three two wire system with three phase system with the same power of the transmitted signal can be formulated as follows. The losses of one three phase system are half of losses of three two wire systems, because it uses three wires instead of six. On the other hand the voltages are increased in the system by the root of three times without reducing the current. If in the two wire system we will raise the voltage at the root of three times, then the current will decrease and the power loss will be reduced by three times
If we compare three phase system and two wires system with the same voltage between lines we will get power loses in three phase system by 3/2 more than in two or one wire systems
5050
Corona, or crown - is a self-discharge that occurs in a highly non-uniform fields, in which the ionization processes can occur only in a narrow region near the electrodes. This sort of field is the electric field wires of overhead power lines.
When a corona discharge in the ionization of air near the surface of the wire is formed the space charge of the same sign as the polarity of the voltage on the wire.
When two oppositely charged corona wires ions of opposite sign move in opposite directions. In the low field strength - in the middle between the wires - there is a partial recombination of the ions. Much the same part of them penetrate the crown area of the opposite polarity, increasing the field there. As a result, the ionization rate increases, the current crown, and, consequently, the energy loss increases. This regime is called bipolar corona crown.
4.2 Corona discharge
One wire Two wires
5151
4.3 Additional power loses
The main advantage of one-wire system is one wire using instead of two or four, which leads to a sharp reduction in the cost of the electrical system.
Another important advantage is the decreases of losses in the transmission of electrical energy.The calculations and simulations show that the mutual influence of the two relatively closely spaced conductors with currents of opposite polarity, resulting in an increase in resistance of both wires.
The one-wire system does not have this problem.
52
There are several categories of twisted-pair cabling, but only three that are commonly used for Ethernet networks: Category 5 (Cat5), Category 5e (Cat5e, or Cat5 Enhanced), and Category 6 (Cat6). The performance characteristics of Cat5, Cat5e, and Cat6 are as follows:•Cat5: Supports speeds up to 100 Mbps at 100 MHz, with a maximum cable length of 328 feet (100 meters).•Cat 5e: Supports speeds up to 1,000 Mbps (or 1 Gbps) at 100 MHz, with a maximum cable length of 328 feet (100 meters).•Cat6: Supports speeds up to 1,000 Mbps (or 1 Gbps) at 250 MHz, with a maximum cable length of 295 feet (90 meters).
See: http://www.dummies.com/how-to/content/what-kind-of-cables-should-i-use-in-my-home-networ.html
The losses in the two wire lines because of the mutual influence in twisted double wire
In a two-wire system with closely spaced wires there is interference between currents. This effect leads to a reduction of the currents in both wires. That is, we get wires resistance increasing.
That is why the phone flat or twisted double wire can not be used over long distances.
Using B-Line method can solve this problem.
53
L1 L1
L2 L2
L2 L2
L1 L1
L1 = L2 = /4
L1 – L2 = /2
R = 10 Ohm
R = 10 Ohm
d = 0.5 mm
V = 1VF = 100 MHz = 3000 mm
Simulation twist line and B-Line
Model 1
Model 2
54
Model 1 – two wires
Simulations were performed for different cable lengths. But the change in length had little impact on the results. No impact on the results and the transition to a twisted cable.
S11
S21
55
Model 2 - B-Line
B-Line acquired selective properties, with sharply reduced losses increased S21 by 16 dB
S11
S21
56
A cross-section through a 400 kV cable, showing the stranded segmented copper conductor in the center, semiconducting and insulating layers, copper shield conductors, aluminum sheath and plastic outer jackethttp://en.wikipedia.org/wiki/High-voltage_cable
Underground cables problems
The losses in the two wire lines increase if if the cables are close to each other.
Transmitted over the air is proportional to the energy efficiency of the transmitting antenna. This efficiency is determined by various inter-related parameters, such as gain (G) or effective length (Le).Electric wire can be considered as a monopole. Le of monopole is inversely proportional to its length-to-quarter wavelength, which for 50 Hz equals 1.5 thousands km. Obviously, to the areas where the distance is less than a kilometer, the active length of electrical wire is zero.
Another source of radiated electromagnetic field can be a transformer, working here as a magnetic antenna.The effective length of the magnetic antenna proportional to coil area (S), the number of coils (N) and the magnetic permeability of the core (). Taking this into account it can be assumed that the output transformer of high voltage electric lines (large output current) can be a real source of electromagnetic radiation.
SN
Le2
Can it be considered an electrical line as an antenna?
Can it be considered an transformer as an antenna?
4.4 Energy radiation
It can be assumed that the output of the high voltage transformer of B-Line, actually which consists of two transformers will have a very low radiation.
H
H
59
S A
2 m
S A
2 m
Electrical antenna
Magnetic antenna
Comparative measurements of the effect of electromagnetic fields on human
http://pscc.ee.ethz.ch/uploads/tx_ethpublications/s13p02.pdf
4.4 Less wires - less short-circuits
61
Possible options for short circuits
B-Line
A-Line
62
Part 5. High-Frequency One-Wire Line
On high frequencies the A-line is long line submitting to telegraph equitation.Let us show that B-line idea is correct for the high frequency too.
If so then we can the long line fragment change by one wire line.
Previous simulations where current by ADS program. This program allows simulating different elements but not electrical lines. For electrical lines simulations was used delay line.On height frequencies one can implement CST program. This program allows simulating different elements including electrical lines.
30 mm
300 mmRin = 300 Ohms Rout = 300 Ohms
1 V 0 V
Model 1
The prototype (model 1) is long line with characteristic impedance ≈ 300 Ohm
63
64
On frequencies more than one GHz is better to use delay line by Strip Line. This Strip Line was used on following simulations.
Model 2
S11
S21
65
66
The matching long the line is infinitely wide band pass. This is an advantage, but also disadvantages.Advantages because you can pass on a long line of multiple signals with different frequencies.However, in a real system there is always some noise. Even if he is weak, but in an infinitely wide band will be infinitely large noise (of course, if the noise is white). Due to Shannon's theory on such a channel can not transmit information.Of course, you can apply a filter at the input of the receiver. But this is often problematic. The filter introduces loss and increases the noise factor.The proposed single-wire system (B-Line) is a selective system
The disadvantage of B-Line is a need to change the delay line in case of change of frequency.
B-Line is compatible with the source and load, and in this sense no different from the usual long line. It is selective, but rather broadband. It has no requirements of symmetry, which is often a problem when using long line inside the apparatus.
Let us note some important advantages of high frequency B-line.
•The line is not so critical to the matching with the load resistance.
•It is difficult to achieve ideal symmetrical two wires long line inside of small device. Non symmetrical can lead to intersymbol interferences For one wire long line the symmetrical is not a problem.
•Long B-line has a resonance properties. This can help to achieving good interference immunity. At the same time the line is broadband enough.
•One of useful antennas is dipole, where the presence of the two beams interfere with the use of dipole as a small device antenna. Maybe B-line idea can help to solve this problem (see next part).
67
69
MB antenna is the equivalent full dipole, and not half-wave, as is usually applied. In the case of a monopole or dipole at the end emitters current is equal to zero, and this dramatically reduces the efficiency of the antennas. At low frequencies to compensate for this effect is used umbrella antenna, T-shaped antenna, antenna with top power, multi-antenna and so on. In contrast to the known solutions the equivalent of half-wave (or rather the wave) MB antenna you can see on Fig.At point A the current is not terminated, it continues to flow to the source.Lines AB and CD equipotential, and they can be combined (see Figure 3). Generator “sees” both ends of the system and gives maximal power. The delay line is small and shielded so that it does not radiate.That is, the MBA allows to implement a PCB radiator of height /2, rather than /4, i.e. the MBA is equivalent to a full dipole. This result is verified by simulations, as described in Section 3.
70
PCB
Strip Line
Vgout = 1V, Rout = 15 Ohm, Distance 1 m. E = 9.872 V/m ! This is much more than give a monopole or dipole
Part 7. B-Line for DC
71
There are two capacitors which in turn charged and discharged. Upon discharge, the current direction changes.
TodayToday
Part 8. Expectations, dreams, hopesPart 8. Expectations, dreams, hopes
72
TomorrowTomorrow
73
74
TodayToday TomorrowTomorrow
Today, in many countries apply three-pin electrical plug.
We can return to the two-pin plugs now, one blade will be active and the other is connected to local protective ground.
Feed line
Stray currentsSuction lines
DC generator
TodayToday
75
One-pole DC generator
TomorrowTomorrow
76
TodayTodayCorona Corona radiationradiation
7777
TomorrowTomorrowNo coronaNo corona
78
79
1. One-way method for connection between source and load by one line – (method B-Line) was proposed and checked. B line can operate at all frequencies, including DC, for all voltages.
2. It is possible to suppose that using one-way method can considerable decrease the electrical lines cost.
3. B-Line method allows to decrease energy loss 4. It is possible to achieve decreasing of electrical lines radiation (Corona
Effect), so far as one of radiation courses in A-lines and three phase systems have high voltage between lines.
5. B-Line method allows simplifying the high-frequency long lines and improving their options, including easing the requirements for symmetry and a good matching.
6. B-Line method allows building antennas with one radiated element (monopole) equivalent to two element antenna (dipole).
7. The transition from a single to multiline systems should drastically reduce the number of accidents and injuries caused by short-circuit.
8. B-Line method allows building one-pole generators and one-pole loads.
ConclusionAll known systems for the transmission of energy or information are the one way systems. This light channels, waveguides, radio links, the fibers, nervous systems in wildlife and others. The exceptions are the wires electric lines.Studies, simulations and experiments have shown that the electric line can be a single channel too. Thus one can expect the following advantages.