Post on 25-Mar-2016
description
transcript
C
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C.1
Contents
PLC Interfaces
H-, R- and S-System
Universal precabling for PLCs C.2
Selection guide C.5
Direct inputs/outputs for digital cards C.20
Opto-decoupled inputs for digital cards C.38
Relay outputs for digital cards C.42
Input / output for analogue cards C.54
PLC Interfaces
C
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C.2
The complexity of machines and installa-tions in industry, processing or building isgiving rise to ever-increasing cablingcosts. The traditional wire to wire cablingbetween the PLC and the inputs/outputsis very expensive during installation andcommissioning. The PLC interface systemoffers the user an easy and quick-to-installsolution for wiring the inputs and outputsof the SIEMENS SIMATIC® S7.
Special front adapters replace the usualscrewed connectors used for the I/Ocards of the PLC. The signals from thePLC are sent to the active or passivecomponents by means of a prefabricatedlead fitted with a 20-pole female connec-tor.
Wire to wire cabling
Most PLC I/O cards use two types ofconnection:
• screw,
• tension clamp.
In each case, the signals are connectedindividually to each connection compo-nent.
Disadvantages of wire to wire cabling:
• high assembly costs,
• risk of error increasing with the numberof wires connected,
• large amount of space taken up in the cabinet,
• high installation costs,
• a lot of time taken up in preparing andlaying the wires,
• a large amount of time taken up in pro-ducing wiring diagrams and drawings.
Wiring interface system
The basic idea is that the PLC’s I/O cardsare connected to the active or passive I/Omodules using prefabricated cables. Frontadapters are directly plugged into thePLC’s I/O cards. The adapter internallyconverts the PLC-specific connectors to an HE connector for ribbon cable (in accor-dance with IEC 603-1/ DIN 41651). The active or passive I/O modules can thus beused independently of the type of PLC.
The wiring interface system has the follo-wing advantages over wire to wire cabling:
• minimum wiring costs,
• reduced installation time,
• the commissioning and the productionof wiring drawings is simplified.
The family of PLC interface modules al-lows the inputs/outputs for main PLC manufacturers to be quickly and easilyconnected.
PLC interface systems
PLC
PLC
Universal precabling for PLCs
C
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C.3
Advantages of the system:
• Quick
– reduced design times,
– time saved during installation,
– reduced commissioning and trouble-shooting times,
– reduced on-site wiring times thanks tothe prefabricated cables.
• Reliable
– no wiring errors,
– clear wiring in the cabinet (cable systeminstead of individual wires),
– labelling corresponding to that of thePLC,
– additional individual labelling.
• Flexible
– many input/output modules (about 40possibilities),
– variable cable lengths,
– modularity of all components,
– configuration of 1 x 4 bytes and 2 x 2bytes without distributor,
– option to mix functions by byte at theI/Os,
– extensions possible without any problem,
– flexibility thanks to the ease in exchanging input/output interfaces.
• Takes up only a small amount ofspace
– more space in the cable ducts,
– narrow modules,
– no terminal block.
PLC interface systems
Inp
uts
Out
put
s
Universal precabling for PLCs
Input:1x1 Byte8 Signals
Input :1x1 Byte8 Signals
Input :1x1 Byte8 Signals
Input :1x1 Byte8 Signals
Output:1x1 Byte8 Signals
Output:1x1 Byte8 Signals
Output:1x1 Byte8 Signals
Output:1x1 Byte8 Signals
C.4
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
Relay outputs – System H
Direct inputs – System R
Thanks to its industrial connector, system R enables the connection of input
signals to a higher voltage of up to 160 V or 250 V.
It is characterised by:
� connector type RSV 1.6 (250 V DC 8 A)
� precabling to PLC – 0.25 mm2 (LIYY)
� input/output interface module boards for digital signals 8, 16, 32-channel
System H ...
… screw or tension clamp, standard or compact
Weidmüller universal precabling for PLCs
Weidmüller’s system H was developed for all PLC types and can be adapted
to suit all situations. Particularly economic, it is characterised by:
� Connector type HE, 10/20 pins, fully protected:extruded-insulation cable, polarised, secure connection
� precabling to PLC – 0.25 mm2 (LIYY)
� connection type selection: screw or tension clamp
� new compact modules, reducing the size of the cabinet
� Input/output of interface modules boards for digital signals: 4, 8, 12, 16 and 32-channel
Universal precabling for PLCs
System R …
… with the RSV 1.6 industrial connector
Analog input/outputs – System S
The sub-d metallic housing is ideal for the transmission of analogue signals:
� Connector sub-d female 15, 25, 37 poles
� Precabling to PLC – 0.25 mm2 shielded (LYC)
� Input/output interface module boards with PE.
System S …
… with shielded Sub-D connector
C
C.5
C
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
* The suffix xxx in the order number shows the length of the cable in dm. the standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 4.00 m (040) - 5.00 m (050).
Note: it is also possible to use the catalogue type of the cable.
In this case the suffix xxxx of the catalogue type shows the length of the cable in cm. The standard lengths are: 1.00 m (0100) – 1.50 m (0150) – 2.00 m (0200) - 3.00 m (0300) – 4.00 m (0400) – 5.00 m (0500)
�PLC Siemens - S7-300
6ES7 321-1BH01 / 1BH81-0AA0
6ES7 321-1BL00 / 1BL80-0AA0
6ES7 321-1BP00-0AA0
6ES7 321-1EH01-0AA0
6ES7 321-1BH50-0AA0
6ES7 321-7BH00 / 7BH80-0AB0
6ES7 321-1FF01 / 1FF81-0AA0
6ES7 321-1EL00-0AA0
6ES7 321-1CH80-0AA0
6ES7 321-7RD00-0AB0
6ES7 322-1BH01 / 1BH81-0AA0
6ES7 322-1BL00-0AA0
6ES7 322-1BP00-0AA0
6ES7 321-1BP50-0AA0
6ES7 322-1EH01-0AA0
6ES7 322-1BF01-0AA0
6ES7 322-1FF01 / 1FF81-0AA0
6ES7 322-1HF01-0AA0
6ES7 322-8BF00-0AB0
6ES7 322-1HH00-0AA0
6ES7 322-1EL00-0AA0
6ES7 322-1HF10 / 1HF80-0AA0
6ES7 322-1CF80-0AA0
6ES7 322-5SD00-0AB0
6ES7 322-5RD00-0AB0
6ES7 323-1BH00 / 1BH80-0AA0
6ES7 323-1BL00-0AA0
6ES7 312-5BD00-0AB0 (312C)
6ES7 313-6CE00-0AB0 (313C-2DP)
6ES7 313-6BE00-0AB0 (313C-2PtP)
6ES7 313-5BE00-0AB0 (313C)
6ES7 314-6CF00-0AB0 (314C-2DP)
6ES7 314-6BF00-0AB0 (314C-2PtP)
6ES7 331-7KF01-0AB0
6ES7 331-7NF00-0AB0
6ES7 331-7RD00-0AB0
6ES7 331-7RD00-0AB0
6ES7 331-7SF00-0AB0
6ES7 331-7PF00-0AB0
6ES7 331-7KB01 / 7KB81-0AB0
6ES7 332-5HD01-0AB0
6ES7 332-5HD01-0AB0
6ES7 332-5HB01 / 5HB81-0AB0
6ES7 332-5HB01 / 5HB81-0AB0
6ES7 332-7ND00-0AB0
6ES7 332-7ND00-0AB0
6ES7 332-5RD00-0AB0
6ES7 332-5HF00-0AB0
6ES7 334-0KE00-0AB0
6ES7 335-7HG01-0AB0
6ES7 334-0CE01-0AA0
7789234xxx
7789236xxx
7789247XXX
7789212xxx
7789234xxx
7789210xxx
7789219xxx
7789215xxx
7789211xxx
7789234xxx
7789234xxx
7789236xxx
7789246XXX
7789246XXX
7789211xxx
7789239xxx
7789219xxx
7789220xxx
7789239xxx
7789214xxx
7789211xxx
7789190xxx
7789191xxx
7789192xxx
7789192xxx
7789237xxx
7789236xxx
7789221xxx
7789222xxx
7789222xxx
7789222xxx
7789223xxx
7789222xxx
7789223xxx
7789222xxx
7789223xxx
7789229xxx
7789231xxx
7789193xxx
7789194xxx
7789229xxx
7789230xxx
7789224xxx
7789228xxx
7789227xxx
7789228xxx
7789227xxx
7789228xxx
7789227xxx
7789195xxx
7789233xxx
7789196xxx
7789226xxx
7789225xxx
7789293xxx
7789293xxx
7789293xxx
7789293xxx
7789293xxx
7789293xxx
1
1
2
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
2
2
16-channel - H B)
32-channel - H A, B)
32-channel - H A, B)
16-channel - R
16-channel - H
16-channel - R
8-channel - R
32-channel - R
16-channel - R
16-channel - H
16-channel - R
8-channel - R
16-channel - R D)
16-channel - R
16-channel - R
16-channel - R D)
8-channel - R
8-channel - H
8-channel - H
8-channel - H
16-channel - H
12-channel - H E)
16-channel - H
16-channel - H
16-channel - H
8-channel - H
16-channel - H
8-channel - H
16-channel - H
8-channel - H
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
16-channel B)
16-channel B)
)
16-channel
1
2
2
1
16-channel C)
32-channel A, C)
32-channel A, C)
32-channel A, C)
8-channel
8-channel
8-channel
16-channel
8-channel E)
16-channel
16-channel
16-channel
16-channel
16-channel
1
1
1
1
1
1
1
1
1
1
1
1
8-channel P
8-channel P
8-channel P
8-channel
16-channel
4-channel
4-channel
8-channel
8-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
8-channel
8-channel
16-channel
16-channel
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Selection guide
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example: Cable 2 metres in length: Order number: 7789236020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
E) Two channels unused
* All I/O signals with same common.
* Addional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Manufacturer order number Type Type Type TypeOrder No. Order No.
I/O cards
PLC Cables Interfaces
Standard SITOP ConnectionDigital Direct
I/Os
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty QtyQty
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
Inp
utA
nal.
Out
put
Dig
ital
I/O
Ana
l.I/
OD
igit
al a
ndA
nal.
I/O
C.6
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
V L 9445530000 RS 8ES-D-L H/V C.21
V 9441540000 (*) RS8ES-DP RSV1,6/V C.21
V L 9445630000 RS 12ES-D-L H/V C.22
C V 9445700000 RS 16ES H/V C.23
C V L 9445710000 RS 16ES-L H/V C.23
Z 9447700000 (*) RS 16ES H/Z C.23
Z L 9447710000 RS 16ES-L H/Z C.23
V L I 9445810000 RS 16ES-S-I-L H/V C.23
C V 9445720000 RS 16ES-D H/V C.24
C V L 9445730000 RS 16ES-D-L H/V C.24
Z L 9447730000 RS 16ES-D-L H/Z C.24
C V L I 9445750000 RS 16ES-D-I-L H/V C.24
Z L I 9447750000 (*) RS 16ES-D-I-L H/Z C.24
V F 9445820000 RS 16ES-D-F H/V C.25
C V 9445760000 RS 16ES-T H/V C.25
C V L 9445770000 RS 16ES-T-L H/V C.25
Z L 9447770000 RS 16ES-T-L H/Z C.25
V 9441500000 RS16ES RSV1,6/V C.26
V I 9441860000 RS16ES-I RSV1,6/V C.26
V 9441700000 RS16ES-DP RSV1,6/V C.27
V F 9441560000 RS16ES-DP/F RSV1,6/V C.27
V I 9441600000 (*) RS16E-3E/I RSV1,6/V C.28
C V 9445900000 RS 32ES H/V C.29
C V L 9445910000 RS 32ES-L H/V C.29
Z 9447900000 (*) RS 32ES H/Z C.29
Z L 9447910000 RS 32ES-L H/Z C.29
V L I 9445870000 RS 32ES-S-I-L H/V C.30
C V L 9445930000 RS 32ES-D-L H/V C.31
Z L 9447930000 RS 32ES-D-L H/Z C.31
C V L I 9445950000 RS 32ES-D-I-L H/V C.32
Z L I 9447950000 (*) RS 32ES-D-I-L H/Z C.32
V F 9445980000 RS 32ES-D-F H/V C.33
C V 9445960000 RS 32ES-T H/V C.34
C V L 9445970000 RS 32ES-T-L H/V C.34
Z L 9447970000 RS 32ES-T-L H/Z C.34
V 9441510000 RS32ES RSV1,6/V C.35
V I 9441870000 RS32ES-I RSV1,6/V C.35
V 9441710000 RS32ES-DP RSV1,6/V C.36
V F 9441570000 (*) RS32ES-DP/F RSV1,6/V C.36
V I 9441610000 RS32E-3E/I RSV1,6/V C.37
Note: Preferably articles in bold (*) under demand
No. of channels
Type of wiring
1 LED per chan.
Discon-nectable
FuseCompact version
Connection
Screw Tension c.
H or R System
Type
Order No. PageType
Functionalities Modules
8chan-nels
H System
H System
2-wire
1-wire
1-wire
2-wire
2-wire
3-wire
3-wire
2-wire
2-wire
H System
1-wire
3-wire
2-wire
H System
R System
R System
1-wire
2-wire
3-wire
R System
12chan.
16chan-nels
32chan-nels
Module overview - Direct inputs/outputs for digital cards
C.20
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
Select the PLC card from the correspon-ding table
Example:• PLC: Siemens S7-300• Card: 6ES7 321-1BL00 / 1BL80-0AA0
Look up the order number for the cable and the quantity to be ordered
Example:• Cable order number 7789236xxx* - Qty 1* see the note at the bottom of the page
�
Refer to the page whose number isgiven at the top of the column
Example:• Please refer to page C.20 Direct inputs/outputs
for digital cards
�
Select the module order number in the family defined at stage 3
Example:• Module order number 944595 – Qty. 1
32-channel module, 2-wire cabling, compact, version with Led, interruptible
• Technical characteristics, page C.32
�
PLC Siemens - S7-300
6ES7 321-1BH01 / 1BH81-0AA0
6ES7 321-1BL00 / 1BL80-0AA0
6ES7 321-1BP00-0AA0
6ES7 321-1EH01-0AA0
6ES7 321-1BH50-0AA0
6ES7 321-7BH00 / 7BH80-0AB0
7789234xxx
7789236xxx
7789247XXX
7789212xxx
7789234xxx
7789210xxx
7789293xxx
7789293xxx
7789293xxx
1
1
2
1
1
1
1
2
1
16-channel - H B)
32-channel - H A, B)
32-channel - H A, B)
16-channel - R
16-channel - H
16-channel - R
1
1
1
1
1
16-channel B)
16-channel B)
)
1
2
2
Manufacturer order number Type TypeOrder No. Order No.
I/O cards
PLC Cables Interfaces
Standard SITOP ConnectionDigital Direct
I/Os
- see page C.20 - - see page C.38 - - se
Digital opto-decoupled input
D
Qty Qty QtyQty
ital
inp
ut
H-,
R-
and
S-S
yste
m
V F 9441560000 RS16ES-DP/F RSV1,6/V C.27
V I 9441600000 (*) RS16E-3E/I RSV1,6/V C.28
C V 9445900000 RS 32ES H/V C.29
C V L 9445910000 RS 32ES-L H/V C.29
Z 9447900000 (*) RS 32ES H/Z C.29
Z L 9447910000 RS 32ES-L H/Z C.29
V L I 9445870000 RS 32ES-S-I-L H/V C.30
C V L 9445930000 RS 32ES-D-L H/V C.31
Z L 9447930000 RS 32ES-D-L H/Z C.31
C V L I 9445950000 RS 32ES-D-I-L H/V C.32
Z L I 9447950000 (*) RS 32ES-D-I-L H/Z C.32
V F 9445980000 RS 32ES-D-F H/V C.33
C V 9445960000 RS 32ES-T H/V C.34
C V L 9445970000 RS 32ES-T-L H/V C.34
Z L 9447970000 RS 32ES-T-L H/Z C.34
V 9441510000 RS32ES RSV1,6/V C.35
V I 9441870000 RS32ES-I RSV1,6/V C.35
V 9441710000 RS32ES-DP RSV1 6/V C 36
3-wire
1-wire
3-wire
2-wire
H System
1-wire
32chan-nels
Using the selection guide
Selection guide
Look up the exact module family and the quantity to be ordered
Example:• 32-channel system H - Qty. 1
or• 16-channel opto-decoupled system H - Qty. 2
�
PLC Siemens - S7-300
6ES7 321-1BH01 / 1BH81-0AA0
6ES7 321-1BL00 / 1BL80-0AA0
6ES7 321-1BP00-0AA0
6ES7 321-1EH01-0AA0
6ES7 321-1BH50-0AA0
6ES7 321-7BH00 / 7BH80-0AB0
6ES7 321-1FF01 / 1FF81-0AA0
6ES7 321-1EL00-0AA0
6ES7 321-1CH80-0AA0
6ES7 321-7RD00-0AB0
6ES7 322-1BH01 / 1BH81-0AA0
6ES7 322-1BL00-0AA0
6ES7 322-1BP00-0AA0
6ES7 321-1BP50-0AA0
6ES7 322-1EH01-0AA0
6ES7 322-1BF01-0AA0
6ES7 322-1FF01 / 1FF81-0AA0
6ES7 322-1HF01-0AA0
6ES7 322-8BF00-0AB0
6ES7 322-1HH00-0AA0
6ES7 322-1EL00-0AA0
6ES7 322-1HF10 / 1HF80-0AA0
6ES7 322-1CF80-0AA0
6ES7 322-5SD00-0AB0
6ES7 322-5RD00-0AB0
6ES7 323-1BH00 / 1BH80-0AA0
6ES7 323-1BL00-0AA0
6ES7 312-5BD00-0AB0 (312C)
6ES7 313-6CE00-0AB0 (313C-2DP)
6ES7 313-6BE00-0AB0 (313C-2PtP)
6ES7 313-5BE00-0AB0 (313C)
6ES7 314-6CF00-0AB0 (314C-2DP)
6ES7 314-6BF00-0AB0 (314C-2PtP)
6ES7 331-7KF01 / 7KF02-0AB0
6ES7 331-7NF00-0AB0
6ES7 331-7RD00-0AB0
6ES7 331-7RD00-0AB0
6ES7 331-7SF00-0AB0
6ES7 331-7PF00-0AB0
6ES7 331-7KB01 / 7KB81-0AB0
6ES7 332-5HD01-0AB0
6ES7 332-5HD01-0AB0
6ES7 332-5HB01 / 5HB81-0AB0
6ES7 332-5HB01 / 5HB81-0AB0
6ES7 332-7ND00-0AB0
6ES7 332-7ND00-0AB0
6ES7 332-5RD00-0AB0
6ES7 332-5HF00-0AB0
6ES7 334-0KE00-0AB0
6ES7 335-7HG01-0AB0
6ES7 334-0CE01-0AA0
7789234xxx
7789236xxx
7789247xxx
7789212xxx
7789234xxx
7789210xxx
7789219xxx
7789215xxx
7789211xxx
7789234xxx
7789234xxx
7789236xxx
7789246xxx
7789246xxx
7789211xxx
7789239xxx
7789219xxx
7789220xxx
7789239xxx
7789214xxx
7789211xxx
7789190xxx
7789191xxx
7789192xxx
7789192xxx
7789237xxx
7789236xxx
7789221xxx
7789222xxx
7789222xxx
7789222xxx
7789223xxx
7789222xxx
7789223xxx
7789222xxx
7789223xxx
7789229xxx
7789231xxx
7789193xxx
7789194xxx
7789229xxx
7789230xxx
7789224xxx
7789228xxx
7789227xxx
7789228xxx
7789227xxx
7789228xxx
7789227xxx
7789195xxx
7789233xxx
7789196xxx
7789226xxx
7789225xxx
7789293xxx
7789293xxx
7789293xxx
7789293xxx
7789293xxx
7789293xxx
1
1
2
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
2
2
16-channel - H B)
32-channel - H A, B)
32-channel - H A, B)
16-channel - R
16-channel - H
16-channel - R
8-channel - R
32-channel - R
16-channel - R
16-channel - H
16-channel - R
8-channel - R
16-channel - R D)
16-channel - R
16-channel - R
16-channel - R D)
8-channel - R
8-channel - H
8-channel - H
8-channel - H
16-channel - H
12-channel - H E)
16-channel - H
16-channel - H
16-channel - H
8-channel - H
16-channel - H
8-channel - H
16-channel - H
8-channel - H
1
1
2
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
16-channel B)
16-channel B)
)
16-channel
1
2
1
16-channel C)
32-channel A, C)
32-channel A, C)
32-channel A, C)
8-channel
8-channel
8-channel
16-channel
8-channel E)
16-channel
16-channel
16-channel
16-channel
16-channel
1
1
1
1
1
1
1
1
1
1
1
1
8-channel P
8-channel P
8-channel P
8-channel
16-channel
4-channel
4-channel
8-channel
8-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
8-channel
8-channel
16-channel
16-channel
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Selection guide
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example: Cable 2 metres in length: Order number: 7789236020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
E) Two channels unused
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Manufacturer order number Type Type Type TypeOrder No. Order No.
I/O cards
PLC Cables Interfaces
Standard SITOP ConnectionDigital Direct
I/Os
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty QtyQty
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
Inp
utA
nal.
Out
put
Dig
ital
I/O
Ana
l.I/
OD
igit
al a
ndA
nal.
I/O
C.6
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
1
1
1
1
1
1
1
7789292xxx
7789278xxx
7789273xxx
7789278xxx
7789290xxx
7789273xxx
7789291xxx
7789292xxx
7789283xxx
7789273xxx
7789270xxx
7789291xxx
7789292xxx
7789287xxx
7789286xxx
7789285xxx
7789285xxx
7789284xxx
7789284xxx
7789288xxx
7789293xxx
7789293xxx
PLC Siemens - S7-400
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789292020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
6ES7 421-1BL00-0AA0
6ES7 421-1EL00-0AA0
6ES7 421-1FH00-0AA0
6ES7 421-7DH00-0AB0
6ES7 421-7BH00-0AB0
6ES7 421-1FH20-0AA0
6ES7 422-1BH10-0AA0
6ES7 422-1BL00-0AA0
6ES7 422-1FF00-0AA0
6ES7 422-1FH00-0AA0
6ES7 422-1HH00-0AA0
6ES7 422-5EH10-0AB0
6ES7 422-7BL00-0AB0
6ES7 431-1KF00-0AB0
6ES7 431-1KF00-0AB0
6ES7 431-1KF10-0AB0
6ES7 431-1KF20-0AB0
6ES7 431-7QH00-0AB0
6ES7 431-0HH00-0AB0
6ES7 432-1HF00-0AB0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
32-channel - H A, B)
32-channel - R
16-channel - R D)
32-channel - R
16-channel - H
16-channel - R
8-channel - R
16-channel - R
32-channel - R
1
1
1
1
1
1
1
1
1
16-channel B) 2
16-channel C)
32-channel C)
16-channel C, F)
32-channel A,C)
1
1
1
1
8-channel
8-channel
8-channel
8-channel
16-channel
16-channel
8-channel
Selection guide
Manufacturer order number
I/O cards
PLC
Ana
l. In
put
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
O
Order No. Order No.
Cables
Standard SITOP Connection
Qty Qty
C.7
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital Direct
I/OsAnal.
input/outputDigital opto-
decoupled inputDigital relay
output
Qty Qty QtyQty
PLC Télémécanique - Micro
TSX DEZ 12D2
TSX DEZ 08A4
TSX DEZ 12D2K
TSX DEZ 08A5
TSX DEZ 32D2
TSX DSZ 04T22
TSX DSZ 08T2
TSX DSZ 08R5
TSX DSZ 08T2K
TSX DSZ 32T2
TSX DSZ 32R5
TSX DMZ 28DT
TSX DMZ 28DR
TSX DMZ 28AR
TSX DMZ 64DTK (*)
TSX DMZ 28DTK
TSX DMZ 16DTK
TSX 37-22 (integrated)
TSX AEZ 801
TSX AEZ 802
TSX AEZ 414
TSX 37-22 (integrated)
TSX ASZ 401
TSX ASZ 200
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
2
1
1
1
1
1
1
1
1
12-channel - H B)
8-channel - R
12-channel - H B)
8-channel - R
32-channel - H A, B)
16-channel - R D)
32-channel - R D)
16-channel - H B)
16-channel - R D)
16-channel - R D)
32-channel - H A, B)
16-channel - H B)
16-channel - H
1
1
1
1
1
1
1
1
2
2
1
1
1
16-channel B, E)
16-channel B, E)
16-channel B)
16-channel B)
16-channel B)
16-channel B)
1
1
2
1
2
1
8-channel C)
8-channel C)
8-channel C)
32-channel A, C)
12-channel C)
32-channel A, C)
12-channel C)
1
1
1
1
1
1
1
9 channels M
8-channel
8-channel
4-channel
9 channels M
4-channel
4-channel
1
1
1
1
1
1
1
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
Inp
utA
nal.
Out
put
Dig
ital
Inp
ut/O
utp
ut
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789301020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
E) Four channels unused
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Selection guide
7789312xxx
7789307xxx
7789301xxx
7789307xxx
7789314xxx
7789312xxx
7789312xxx
7789308xxx
7789301xxx
7789314xxx
7789330xxx
7789313xxx
7789331xxx
7789331xxx
7789301xxx
7789301xxx
7789301xxx
7789257xxx
7789311xxx
7789311xxx
7789309xxx
7789257xxx
7789310xxx
7789310xxx
Manufacturer order number Type Type Type TypeOrder No.
I/O cards
PLC Cables Interfaces
StandardDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty Qty
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
C.8
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
1
1
1
1
1
2
1
1
1
PLC Télémécanique - Premium
7789322xxx
7789322xxx
7789322xxx
7789315xxx
7789315xxx
7789315xxx
7789315xxx
7789301xxx
7789301xxx
7789301xxx
7789322xxx
7789317xxx
7789322xxx
7789317xxx
7789322xxx
7789316xxx
7789316xxx
7789318xxx
7789318xxx
7789316xxx
7789316xxx
7789301xxx
7789301xxx
7789320xxx
7789319xxx
7789259xxx
7789259xxx
7789261xxx
7789259xxx
7789320xxx
7789321xxx
7789259xxx
TSX DEY 08D2
TSX DEY 16D2
TSX DEY 16D3
TSX DEY 16A2 (1)
TSX DEY 16A3
TSX DEY 16A4
TSX DEY 16A5
TSX DEY 16FK (*)
TSX DEY 32D2K (*)
TSX DEY 64D2K (*)
TSX DSY 08T2
TSX DSY 08T22
TSX DSY 16T2
TSX DSY 08T31
TSX DSY 16T3
TSX DSY 08R5
TSX DSY 16R5
TSX DSY 08R5A
TSX DSY 08R4D
TSX DSY 08S5
TSX DSY 16S4
TSX DSY 32T2K (*)
TSX DSY 64T2K (*)
TSX AEY 414
TSX AEY 414
TSX AEY 420
TSX AEY 800
TSX AEY 810
TSX AEY 1600
TSX ASY 410
TSX ASY 410
TSX ASY 800
1
1
1
1
1
1
1
1
2
4
1
1
1
1
1
1
1
1
1
1
1
2
4
1
1
1
1
1
2
1
1
1
8-channel - H
16-channel - H B)
16-channel - H B, G)
16-channel - R
16-channel - R
16-channel - R
16-channel - R D)
16-channel - H B)
32-channel - H A, B)
32-channel - H A, B)
8-channel - R
8-channel - R
16-channel - H G)
16-channel - R D)
16-channel - R D)
16-channel - R D)
16-channel - R
16-channel - R D)
16-channel - R
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
16-channel B)
16-channel B)
16-channel B)
16-channel B)
16-channel B)
1
1
1
1
1
1
1
1
2
4
8-channel C)
16-channel C)
32-channel A,C)
32-channel A,C)
1
1
1
2
4-channel
8-channel
8-channel P
8-channel P
8-channel P
8-channel P
4-channel
4-channel
8-channel P
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789301020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
G) Only use modules without LED
1) Use in ac mode
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Selection guide
Manufacturer order number
I/O cards
PLC
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
Inp
utA
nal.
Out
put
Order No.
Cables
Standard
Qty
C.9
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
PLC Télémécanique - Twido
TWD DDI 8DT
TWD DDI 16DT
TWD DDI 16DK (1)
TWD DDI 32DK (1)
TWD DDO 8UT
TWD DDO 8TT
TWD DDO 16UK
TWD DDO 16TK
TWD DDO 32UK
TWD DDO 32TK
TWD DRA 8RT
TWD DRA 16RT
TWD LMDA 20DTK (1)
TWD LMDA 20DUK (1)
TWD LMDA 20DTR
TWD LMDA 40DTK (1)
TWD LMDA 40DUK (1)
TWD AMI 2HT
TWD AMO 1HT
TWD AMM 3HT
TWD ALM 3LT
1
1
1
2
1
1
1
1
2
2
1
1
1
1
1
1
2
2
1
1
1
1
8-channel - H
16-channel - H B)
16-channel - H B)
32-channel - H A, B)
8-channel - H
16-channel - H
32-channel - H A)
8-channel - R
16-channel - R D)
12-channel - H B)
12-channel - H B)
8-channel - H
12-channel - H B)
16-channel - R D)
12-channel - H B)
12-channel - H
8-channel - H
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
16-channel B)
16-channel B)
16-channel B)
16-channel B)
16-channel B)
16-channel B)
16-channel B)
1
1
2
1
1
1
2
8-channel C)
16-channel C)
32-channel A,C)
8-channel C)
8-channel C)
1
1
1
1
2
4-channel
4-channel
4-channel
4-channel
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789100020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
1) Use in positive logic
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Selection guide
7789100xxx
7789100xxx
7789328xxx
7789328xxx
7789100xxx
7789100xxx
7789328xxx
7789329xxx
7789328xxx
7789329xxx
7789108xxx
7789104xxx
7789327xxx
7789326xxx
7789100xxx
7789104xxx
7789327xxx
7789326xxx
7789250xxx
7789250xxx
7789250xxx
7789250xxx
Manufacturer order number
I/O cards
PLC
Dig
ital
in
put
Dig
ital
out
put
Dig
ital
I/O
Ana
l. I/
O
Order No.
Cables
Standard
Qty
C.10
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
PLC Télémécanique - Quantum
140 DAI 540 00
140 DAI 540 00
140 DAI 553 00
140 DAI 740 00
140 DAI 740 00
140 DAI 340 00
140 DAI 340 00
140 DAI 353 00
140 DAI 440 00
140 DAI 440 00
140 DAI 453 00
140 DDI 841 00
140 DDI 853 00
140 DDI 353 00
140 DDI 364 00
140 DAO 840 00
140 DAO 840 00
140 DAO 842 10
140 DDO 353 00
140 DDO 843 00
140 DDO 364 00
140 DRA 840 00
140 DDM 390 00
140 ACI 030 00
140 ACI 030 00
140 AVI 030 00
140 AVI 030 00
140 ARI 030 10
140 ACI 040 00
140 AII 330 00
140 ACO 020 00
140 ACO 130 00
140 AIO 330 00
1
1
1
1
1
1
1
1
1
1
1
1
1
1
6
1
1
1
1
1
6
1
1
32-channel - R
16-channel - R
32-channel - R
32-channel - R D)
16-channel - R D)
32-channel - R
16-channel - R
32-channel - R
32-channel - R
16-channel - R
32-channel - R
16-channel - H B)
32-channel - H A, B)
32-channel - H A, B)
32-channel - H A, B)
32-channel - R D)
16-channel - R D)
16-channel - R D)
32-channel - R D)
16-channel - H B)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
1
1
16-channel B)
16-channel B)
16-channel B)
16-channel B)
16-channel B)
1
2
2
6
1
32-channel A, C)
16-channel C, F)
32-channel A, C)
8-channel C)
1
1
3
1
8-channel
8-channel
8-channel
8-channel
8-channel
16-channel
8-channel
4-channel
8-channel
8-channel
1
1
1
1
1
1
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789301020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Selection guide
7789118xxx
7789110xxx
7789118xxx
7789118xxx
7789110xxx
7789118xxx
7789110xxx
7789118xxx
7789118xxx
7789110xxx
7789118xxx
7789119xxx
7789121xxx
7789121xxx
7789301xxx
7789118xxx
7789112xxx
7789113xxx
7789121xxx
7789120xxx
7789301xxx
7789118xxx
7789133xxx
7789125xxx
7789134xxx
7789125xxx
7789134xxx
7789135xxx
7789123xxx
7789136xxx
7789124xxx
7789126xxx
7789137xxx
Manufacturer order number
I/O cards
PLC
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
Inp
utA
nal.
Out
put
Dig
.I/
O
Order No.
Cables
Standard
Qty
C.11
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
PLC Télémécanique - M340
BMX DDI 1602
BMX DDI 1603
BMX DDI 3202K
BMX DDI 6402K
BMX DAI 1602 (1)
BMX DAI 1602 (2)
BMX DAI 1603
BMX DAI 1604
BMX DAO 1605
BMX DDO 1602
BMX DDO 1612
BMX DDO 3202K
BMX DDO 6402K
BMX DRA 0805
BMX DRA 1605
BMX DDM 16025
BMX DDM 16022
BMX DDM 3202K
BMX AMI 0410 (3)
BMX AMI 0410 (4)
BMX ART 0414
BMX ART 0814
BMX AMO 0210
BMX AMM 0600 (3)
BMX AMM 0600 (4)
1
1
1
2
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
2
1
1
1
16 channels-H (B)
16 channels-R
32 channels-H (A) (B)
32 channels-H (A) (B)
16 channels-H (B)
16 channels-R
16 channels-R
16 channels-R
16 channels-R (D) (K)
16 channels-R (D)
16 channels-R (D)
8 channels-H
8 channels-R (D)
8 channels-H
16 channels-H
1
1
1
2
1
1
1
1
1
1
1
1
1
2
2
16 channels-H (B)
16 channels-H (B)
16 channels-H (B)
16 channels-H (B)
1
2
4
1
16 channels (C)
16 channels (C)
16 channels (C)
16 channels (C)
1
1
2
4
4 channels
4 channels
16 channels
16 channels
4 channels
4 channels
4 channels
1
1
1
2
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789236020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
K) Each interface have one common
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
(1) use in 24 VDC, negative logic
(2) use in 24 VAC
(3) Use this cable for voltage signals.
(4) Use this cable for current signals.
Selection guide
7789380xxx
7789382xxx
7789387xxx
7789387xxx
7789630xxx
7789382xxx
7789382xxx
7789382xxx
7789383xxx
7789380xxx
7789380xxx
7789387xxx
7789387xxx
7789633xxx
7789384xxx
7789635xxx
7789386xxx
7789387xxx
7789637xxx
7789638xxx
7789639xxx
7789639xxx
7789640xxx
7789628xxx
7789629xxx
Manufacturer order number
I/O cards
PLC
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
Inp
utA
nal.
I/O
Dig
ital
I/O
Order No.
Cables
Standard
Qty
Ana
l. O
C.12
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
PLC Rockwell - SLC 500
1746 - IB32
1746 - IV32
1746 - IB16
1746 - IC16
1746 - IN16
1746 - ITB16
1746 - ITV16
1746 - IV16
1746 - IB8
1746 - IV8
1746 - OB32
1746 - OV32
1746 - OB16
1746 - OB16E
1746 - OBP16
1746 - OG16
1746 - OV16
1746 - OVP16
1746 - OW16
1746 - OB8
1746 - OBP8
1746 - OV8
1746 - OW8
1746 - OX8
1746 - OW4
1746 - NI8
1746 - NI4
1746 - NO4V
1746 - NO4I
1746 - NIO4V
1746 - NIO4I
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
32-channel - H A, B)
32-channel - H A)
16-channel - H
16-channel - H
16-channel - H
16-channel - H
16-channel - H
16-channel - H
8-channel - H
8-channel - H
32-channel - H A)
16-channel - H
16-channel - H
16-channel - H
8-channel - H
16-channel - H F)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
16-channel B) 2
32-channel A, C)
16-channel C)
16-channel C)
16-channel C)
16-channel C, F)
8-channel C)
8-channel C)
8-channel C, F)
8-channel C, F)
1
1
1
1
1
1
1
1
1
8-channel
4-channel
4-channel
4-channel
4-channel
4-channel
1
1
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789005020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
7789005xxx
7789670xxx
7789001xxx
7789001xxx
7789001xxx
7789001xxx
7789000xxx
7789000xxx
7789100xxx
7789100xxx
7789006xxx
7789006xxx
7789003xxx
7789003xxx
7789003xxx
7789003xxx
7789003xxx
7789003xxx
7789002xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789011xxx
7789008xxx
7789010xxx
7789010xxx
7789009xxx
7789009xxx
Manufacturer order number
I/O cards
PLC
Selection guide
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
IA
nal.
OA
nal.
I/O
Order No.
Cables
Standard
Qty
C.13
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
Selection guide
PLC Rockwell - Compact Logix
1769 - IA8I
1769 - IM12
1769 - IA16
1769 - IQ16
1769 - IQ16F
1769 - IQ32
1769 - OA8
1769 - OB8
1769 - OW8
1769 - OW8I
1769 - OA16
1769 - OB16
1769 - OB16P
1769 - OV16
1769 - OW16
1769 - OB32
1769 - IQ6XOW4
1769 - IF4
1769 - IF4I
1769 - IF8
1769 - OF2
1769 - OF4CI
1769 - OF8V
1769 - OF8C
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
16-channel - R
16-channel - R
16-channel - R
16-channel - H
16-channel - H
16-channel - H
8-channel - R
8-channel - R
16-channel - R
16-channel - R
16-channel - H
16-channel - R
16-channel - R
1
1
1
1
1
2
1
1
1
1
1
1
1
8-channel C)
16-channel C)
16-channel C)
16-channel C)
1
1
1
2
4-channel
4-channel
4-channel
4-channel
8-channel
8-channel
4-channel
4-channel
8-channel
8-channel
1
1
1
1
1
1
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789019020
Notes concerning the use of interface modules:
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
7789016xxx
7789025xxx
7789025xxx
7789019xxx
7789019xxx
7789019xxx
7789017xxx
7789015xxx
7789017xxx
7789016xxx
7789024xxx
7789018xxx
7789018xxx
7789018xxx
7789024xxx
7789018xxx
7789014xxx
7789026xxx
7789046xxx
7789027xxx
7789047xxx
7789028xxx
7789045xxx
7789029xxx
7789043xxx
7789044xxx
7789044xxx
Manufacturer order number
I/O cards
PLC
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
Inp
utA
nal.
Out
put
Dig
.I/
O
Order No.
Cables
Standard
Qty
C.14
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
PLC Rockwell - Control Logix
1756-IA16
1756-IA16I
1756-IA8D
1756 - IB16
1756-IB16D
1756-IB16I
1756-IB32
1756 - IC16
1756-IH16I
1756-IM16I
1756 - IN16
1756 - OA16
1756-OA16I
1756 - OA8
1756-OA8D
1756-OA8E
1756-OB16D
1756 - OB16E
1756-OB16I
1756 - OB32
1756 - OB8
1756-OB8EI
1756-OC8
1756-OH8I
1756-ON8
1756-OW16I
1756-OX8I
1756-IF6I
1756-IF6I
1756-IF16
1756 - IF8
1756 - IF8
1756-IR6I
1756-OF4
1756-OF4
1756-OF6VI
1756-OF6CI
1756-OF8
1756-OF8
1756-OV16E
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
16-channel - R
32-channel - R
8-channel - R
16-channel - H B)
16-channel - H B)
16-channel - H B)
32-channel - H A, B)
16-channel - R
32-channel - R
32-channel - R D)
16-channel - R
16-channel - R D)
32-channel - R D)
8-channel - R
8-channel - R
8-channel - R
16-channel - R
16-channel - R
8-channel - R
32-channel - R D)
16-channel - R D)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
16-channel B)
16-channel B)
16-channel B)
16-channel B)
1
1
1
2
16-channel C)
16-channel C)
16-channel C)
32-channel A, C)
8-channel C)
8-channel C)
1
1
1
1
1
1
8-channel
8-channel
16-channel
8-channel
8-channel
8-channel
4-channel
4-channel
8-channel
8-channel
8-channel
8-channel
16-channel
1
1
1
1
1
1
1
1
1
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789031020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Selection guide
7789031xxx
7789030xxx
7789048xxx
7789039xxx
7789049xxx
7789049xxx
7789041xxx
7789031xxx
7789030xxx
7789030xxx
7789031xxx
7789056xxx
7789030xxx
7789057xxx
7789048xxx
7789048xxx
7789040xxx
7789058xxx
7789059xxx
7789042xxx
7789151xxx
7789152xxx
7789153xxx
7789154xxx
7789057xxx
7789030xxx
7789155xxx
7789156xxx
7789157xxx
7789032xxx
7789035xxx
7789036xxx
7789158xxx
7789033xxx
7789034xxx
7789157xxx
7789159xxx
7789037xxx
7789038xxx
7789165xxx
Manufacturer order number
I/O cards
PLC
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
IA
nal.
O
Order No.
Cables
Standard
Qty
C.15
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
PLC Fanuc 90-30 and Alspa 8035
7789064xxx
7789064xxx
7789061xxx
7789067xxx
7789067xxx
7789634xxx
7789067xxx
7789067xxx
7789067xxx
7789067xxx
7789067xxx
7789066xxx
7789066xxx
7789063xxx
7789063xxx
7789069xxx
7789069xxx
7789068xxx
7789068xxx
7789068xxx
7789068xxx
7789068xxx
7789066xxx
7789066xxx
7789076xxx
7789075xxx
7789072xxx
7789072xxx
7789073xxx
7789073xxx
7789074xxx
IC693MDL230
IC693MDL231
IC693MDL240
IC693MDL241
IC693MDL630
IC693MDL632
IC693MDL634
IC693MDL640
IC693MDL643
IC693MDL645
IC693MDL646
IC693MDL654
IC693MDL655
IC693MDL310
IC693MDL340
IC693MDL730
IC693MDL731
IC693MDL732
IC693MDL733
IC693MDL740
IC693MDL741
IC693MDL742
IC693MDL752
IC693MDL753
IC693ALG220
IC693ALG221
IC693ALG222
IC693ALG223
IC693ALG390
IC693ALG391
IC693ALG442
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
16-channel - R
16-channel - R D)
16-channel - R
16-channel - H B, H)
8-channel - H
8-channel - R
8-channel - H H)
16-channel - H B)
16-channel - H B)
16-channel - H B, H)
16-channel - H B, H)
32-channel - H A, B, H)
32-channel - H A, B, H)
16-channel - R
16-channel - R
8-channel - H
8-channel - H
16-channel - H
32-channel - H A)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
16-channel B, H)
16-channel B)
16-channel B)
16-channel B, H)
16-channel B, H)
16-channel B, H)
16-channel B, H)
1
1
1
1
1
2
2
8-channel C, F)
8-channel C, F)
16-channel C, F)
16-channel C, F)
32-channel A, C)
1
1
1
1
1
4-channel
4-channel
8-channel
8-channel
8-channel
8-channel
16-channel
1
1
1
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789067020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)
H) Use the PLC I/O card in positive logic only
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Selection guide
Manufacturer order number
I/O cards
PLC
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
In-
put
Ana
l. O
Ana
l. I
/O
Order No.
Cables
Standard
Qty
C.16
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
PLC OMRON CQM1
ID211
ID212
ID213
IA121
IA221
OC221
OC222
OD211
OD212
OD213
OD214
OA221
AD041
DA021
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
16-channel B, H)
16-channel B, H)
1
2
32-channel A, C)
16-channel C)
1
1
8-channel J)
4-channel J)
1
1
16-channel - H
16-channel - H B), H)
32-channel - H B, H)
8-channel - R
8-channel - R
8-channel - R
16-channel - R
8-channel - H
16-channel - H
8-channel - R
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789143020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
H) Only for positive logic, for negative logic invert the polarity of the source on the interface.
J) The PLC connector is not included. The wires of the cable are free and equiped with ferrules.
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Selection guide
7789646xxx
7789647xxx
7789370xxx
7789652xxx
7789652xxx
7789653xxx
7789654xxx
7789653xxx
7789655xxx
7789372xxx
7789655xxx
7789656xxx
7789252xxx
7789250xxx
Manufacturer order number
I/O cards
PLC
Dig
ital
inp
utD
igit
al o
utp
utA
nal.
IA
nal.
O
Order No.
Cables
Standard
Qty
C.17
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
ID211
ID001
ID002
IA121
IA122
IM211
ID212
IA122-V
IA222-V
IM212
ID216
ID217
OC221
OC224-V
OC223
OD214
OD411
OD213
OA221
OC222-V
OD217
OD211
OA222-V
OC225
OD212
7789100xxx
7789100xxx
7789100xxx
7789108xxx
7789104xxx
7789108xxx
7789100xxx
7789104xxx
7789104xxx
7789100xxx
7789370xxx
7789370xxx
7789108xxx
7789104xxx
7789108xxx
7789100xxx
7789100xxx
7789100xxx
7789108xxx
7789104xxx
7789100xxx
7789100xxx
7789104xxx
7789104xxx
7789100xxx
PLC OMRON C200H
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
8-channel - H J)
8-channel - H J)
8-channel - H J)
8-channel - R J)
16-channel - R J)
8-channel - H J)
16-channel - H B, J)
16-channel - R J)
16-channel - R J)
16-channel - H B, J)
32-channel - H A, B, H)
32-channel - H A, B, H)
8-channel - R J)
16-channel - R J)
8-channel - R J)
8-channel - H J)
8-channel - H J)
8-channel - R J)
16-channel - R J)
12-channel - H J)
16-channel - R J)
16-channel - R J)
16-channel - H J)
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
16-channel B, J)
16-channel B, J)
16-channel B)
16-channel B)
1
1
2
4
8-channel C, J)
12-channel C, J)
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789142020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
H) Only for positive logic, for negative logic invert the polarity of the source on the interface.
J) The PLC connector is not included. The wires of the cable are free and equiped with forks.
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Selection guide
Manufacturer order number
I/O cards
PLC
Dig
ital
inp
utD
igit
al o
utp
ut
Order No.
Cables
Standard
Qty
C.18
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
ID211
ID231
ID232
ID261
ID262
IA111
IA201
OC201
OC211
OD201
OD202
OD211
OD212
OD231
OD232
OD233
OD261
OD263
OA201
Dig
ital
inp
utD
igit
al o
utp
ut
7789645xxx
7789370xxx
7789371xxx
7789370xxx
7789371xxx
7789664xxx
7789648xxx
7789649xxx
7789664xxx
7789650xxx
7789650xxx
7789651xxx
7789651xxx
7789372xxx
7789373xxx
7789373xxx
7789372xxx
7789373xxx
7789648xxx
PLC OMRON CJ1W
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
2
2
1
16-channel - H B, H)
32-channel - H A, B, H)
32-channel - H A, B, H)
32-channel - H A, B, H)
32-channel - H A, B, H)
16-channel - R
8-channel - R
16-channel - R
16-channel - R
8-channel - H
32-channel - H A)
32-channel - H A)
32-channel - H A)
8-channel - R
1
1
1
2
2
1
1
1
1
1
1
2
2
1
16-channel B)
16-channel B)
16-channel B)
16-channel B)
16-channel B)
1
2
2
4
4
8-channel C)
16-channel C)
16-channel C)
32-channel A, C)
32-channel A, C)
1
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 metres in length: Order number: 7789100020
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
H) Only for positive logic, for negative logic invert the polarity of the source on the interface.
* All I/O signals with same common.
* Additional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
Selection guide
Manufacturer order number
I/O cards
PLC
Order No.
Cables
Standard
Qty
C.19
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
- see page C.20 - - see page C.38 - - see page C.42 - - see page C.54 -
Type Type Type Type
InterfacesDigital directinput/output
Anal. input/output
Digital opto-decoupled input
Digital relayoutput
Qty Qty Qty Qty
V L 9445530000 RS 8ES-D-L H/V C.21
V 9441540000 (*) RS8ES-DP RSV1,6/V C.21
V L 9445630000 RS 12ES-D-L H/V C.22
C V 9445700000 RS 16ES H/V C.23
C V L 9445710000 RS 16ES-L H/V C.23
Z 9447700000 (*) RS 16ES H/Z C.23
Z L 9447710000 RS 16ES-L H/Z C.23
V L I 9445810000 RS 16ES-S-I-L H/V C.23
C V 9445720000 RS 16ES-D H/V C.24
C V L 9445730000 RS 16ES-D-L H/V C.24
Z L 9447730000 RS 16ES-D-L H/Z C.24
C V L I 9445750000 RS 16ES-D-I-L H/V C.24
Z L I 9447750000 (*) RS 16ES-D-I-L H/Z C.24
V F 9445820000 RS 16ES-D-F H/V C.25
C V 9445760000 RS 16ES-T H/V C.25
C V L 9445770000 RS 16ES-T-L H/V C.25
Z L 9447770000 RS 16ES-T-L H/Z C.25
V 9441500000 RS16ES RSV1,6/V C.26
V I 9441860000 RS16ES-I RSV1,6/V C.26
V 9441700000 RS16ES-DP RSV1,6/V C.27
V F 9441560000 RS16ES-DP/F RSV1,6/V C.27
V I 9441600000 (*) RS16E-3E/I RSV1,6/V C.28
C V 9445900000 RS 32ES H/V C.29
C V L 9445910000 RS 32ES-L H/V C.29
Z 9447900000 (*) RS 32ES H/Z C.29
Z L 9447910000 RS 32ES-L H/Z C.29
V L I 9445870000 RS 32ES-S-I-L H/V C.30
C V L 9445930000 RS 32ES-D-L H/V C.31
Z L 9447930000 RS 32ES-D-L H/Z C.31
C V L I 9445950000 RS 32ES-D-I-L H/V C.32
Z L I 9447950000 (*) RS 32ES-D-I-L H/Z C.32
V F 9445980000 RS 32ES-D-F H/V C.33
C V 9445960000 RS 32ES-T H/V C.34
C V L 9445970000 RS 32ES-T-L H/V C.34
Z L 9447970000 RS 32ES-T-L H/Z C.34
V 9441510000 RS32ES RSV1,6/V C.35
V I 9441870000 RS32ES-I RSV1,6/V C.35
V 9441710000 RS32ES-DP RSV1,6/V C.36
V F 9441570000 (*) RS32ES-DP/F RSV1,6/V C.36
V I 9441610000 RS32E-3E/I RSV1,6/V C.37
Note: Preferably articles in bold (*) under demand
No. of channels
Type of wiring
1 LED per chan.
Discon-nectable
FuseCompact version
Connection
Screw Tension c.
H or R System
Type
Order No. PageType
Functionalities Modules
8chan-nels
H System
H System
2-wire
1-wire
1-wire
2-wire
2-wire
3-wire
3-wire
2-wire
2-wire
H System
1-wire
3-wire
2-wire
H System
R System
R System
1-wire
2-wire
3-wire
R System
12chan.
16chan-nels
32chan-nels
Module overview - Direct inputs/outputs for digital cards
C.20
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
Direct inputs/outputs for digital cards
For 8-channel digital I/O cardsH System and R System
RS ES-D - 8-channel RS ES-DP - 8-channel
H-System – 2-wire (common + or –)Version: screw connection
R-System – 2-wire (common + or –)Version: screw connection
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
--
+F+
18
20
1719
0.0 1
0.1 2
0.2 3
0.3 4
80.7
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
Connector H
E10/20 poles
B
C
A
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
24 V DC ± 10%
1 A (*)
3 A
–
–
Green
+ or – selectable with a jumper
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
74 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
RSV 1.6 connector – 12 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
250 V max
1 A (*)
3 A
–
–
–
+ or – selectable with a jumper
3 A
max 250 V
2 A
3.15 A
250 V AC
III
2
1.7 KV DC
-25…50 ºC
-40…60 ºC
68 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS 8ES-D-L H/V 9445530000
Type Order No.
RS8ES-DP RSV1,6/V 9441540000 (1)
(1) on demand
C.21
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
Direct inputs/outputs for digital cards
For 12-channel digital I/O cardsSystem H
RS ES-D - 12-channel
H-System – 2-wire (common + or –)Version: screw connection
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
--
+F+
18
20
1719
0.0 1
0.1 2
0.2 3
0.3 4
121.3
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
Connector H
E10/20 poles
B
C
A
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
24 V DC ± 10%
1 A (*)
3 A
–
–
Green
+ or – selectable with a jumper
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
95 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
Type Order No.
RS 12ES-D-L H/V 9445630000
C.22
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
Direct inputs/outputs for digital cards
For 16-channel digital I/O cardsSystem H
RS ES-S - 16-channel RS ES-S-I - 16 disconnectable channels
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
--
+F+
18
20
1719
0.0 1
0.1 2
0.2 3
0.3 4
161.7
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
Connector H
E10/20 poles
B
C
A
--
+F+
18
20
1719
0.0 1
0.1 2
0.2 3
0.3 4
161.7
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
Connector H
E10/20 poles
Disconnectableconnector
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
C version mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3 A
–
–
Green (versions with LED)
–
–
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
81 x 87.5 x 72
46 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
24 V DC ± 10%
1 A (*)
3 A
–
Yes - each channel
Green
–
–
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
110 x 87.5 x72
(*) Observe the max. permissible current for the common wires
C
Type Order No.
RS 16ES H/V C C 9445700000
RS 16ES-L H/V C C 9445710000
RS 16ES H/Z 9447700000 (1)
RS 16ES-L H/Z 9447710000
C : compact version(1) on demand
Type Order No.
RS 16ES-S-I-L H/V 9445810000
C.23
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
CC
Direct inputs/outputs for digital cards
For 16-channel digital I/O cardsSystem H
RS ES-D - 16-channel RS ES-D-I - 16 disconnectable channels
H-System – 2-wire (common + or –)Versions: screw / tension clamp connection - compact
H-System – 2-wire (common + or –)Versions: screw / tension clamp connection - compact
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
--
+F+
18
20
1719
0.0 1
0.1 2
0.2 3
0.3 4
161.7
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
Connector H
E10/20 poles
B
C
A--
+F+
18
20
1719
0.0 1
0.1 2
0.2 3
0.3 4
161.7
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
Disconnectableconnector
Connector H
E10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
C version mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3 A
–
–
Green (versions with LED)
+ or – selectable with a jumper
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
117 x 87.5 x 72
87 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
24 V DC ± 10%
1 A (*)
3 A
–
Yes - each channel
Green
+ or – selectable with a jumper
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
119 x 87.5 x 72
90 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS 16ES-D H/V C C 9445720000
RS 16ES-D-L H/V C C 9445730000
RS 16ES-D-L H/Z 9447730000
C : compact version
Type Order No.
RS 16ES-D-I-L H/V C C 9445750000
RS 16ES-D-I-L H/Z 9447750000 (1)
C : compact version(1) on demand
C.24
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
C
Direct inputs/outputs for digital cards
For 16-channel digital I/O cardsSystem H
RS ES-D-F - 16-channel with fuse RS ES-T - 16-channel
H-System – 2-wire (common + or –)Version: screw connection
H System – 3-wire (common + and –)Versions: screw / tension clamp connection - compact
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
--
+F+
18
20
1719
0.0 1
0.1 2
0.2 3
0.3 4
161.7
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
FUS
FUS
FUS
FUS
FUS
Connector H
E10/20 poles
B
C
A
--
+F+
18
20
1719
0.0 1
0.1 2
0.2 3
0.3 4
161.7
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
+
+
+
+
+
-
-
-
-
+F
Connector H
E10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
C version mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
≤ 25V AC 50 V DC
1 A (*)
3 A
0.5 A fuse on each channel
–
–
+ or – selectable with a jumper
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
122 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3 A
–
–
Green (versions with LED)
+ and –
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
110 x 87.5 x72
90 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS 16ES-D-F H/V 9445820000
Type Order No.
RS 16ES-T H/V C 9445760000
RS 16ES-T-L H/V C 9445770000
RS 16ES-T-L H/Z 9447770000
C : compact version
C.25
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 16-channel digital I/O cardsSystem R
RS ES - 16-channel RS ES-I – 16 disconnectable channels
System R – 1-wire cablingVersion: screw connection
System R – 1-wire cablingVersion: screw connection
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Note
Dimensions
Ordering data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
RSV 1.6 connector - 24 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3 A
–
–
–
–
–
max 150 V
2 A
–
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
97 x 87.5 x 68
(*) Observe the max. permissible current for the common wires
Technical data
RSV 1.6 connector - 24 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
250 V max
1 A (*)
3 A
–
Yes - each channel
–
–
–
max 250 V
2 A
3.15 A
250 V AC
III
2
1.7 KV DC
-25…50 ºC
-40…60 ºC
127 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS16ES RSV1,6/V 9441500000
Type Order No.
RS16ES-I RSV1,6/V 9441860000
C.26
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 16-channel digital I/O cardsSystem R
RS ES-DP - 16-channel RS ES-DP/F - 16-channel with fuse
R-System – 2-wire (common + or –)Version: screw connection
R-System – 2-wire (common + or –)Version: screw connection
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Note
Dimensions
Ordering data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
RSV 1.6 connector - 24 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3 A
–
–
–
+ or – selectable with a jumper
3 A
max 150 V UC
2 A
3.15 A
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
123 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
RSV 1.6 connector - 24 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3 A
1 A fuse on each channel
–
–
+ or – selectable with a jumper
3 A
max 150 V UC
2 A
3.15 A
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
123 x 109 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS16ES-DP RSV1,6/V 9441700000
Type Order No.
RS16ES-DP/F RSV1,6/V 9441560000
C.27
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 16-channel digital I/O cardsSystem R
RS ES-3 E/I - 16 disconnectable channels
R System – 3-wire (common + and –)Version: screw connection
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Note
Dimensions
Ordering data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
RSV 1.6 connector - 24 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3 A
–
Yes - each channel
–
+ and –
3 A
max 150 V UC
3.15 A
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
116 x 109 x 84
(*) Observe the max. permissible current for the common wires
Technical data
Type Order No.
RS16E-3E/I RSV1,6/V 9441600000 (1)
(1) on demand
C.28
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 32-channel digital I/O cardsSystem H
RS ES-S - 32-channel RS ES-S - 32-channel
H System – 1-wireVersion: screw connection - compact
H System – 1-wireVersion: tension clamp
C
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
--
+F+
1820
1719
0.0 1
0.1 2
161.7I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
1820
1719
I/O P
CB
Con
nect
or
2.0 1
2.1 2
163.7
Connector (1) H
E10/20 poles C
onnector (2) HE
10/20 polesB
C
A
--
+F+
1820
1719
0.0 1
0.1 2
161.7I/O P
CB
Con
nect
orS
uppl
y V
olta
ge 1
FUS
I/O P
CB
Con
nect
or
2.0 1
2.1 2
163.7
--
+F+
1820
1719
Sup
ply
Vol
tage
2FUS
Connector (1) H
E10/20 poles C
onnector (2) HE
10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C C version mm
Length A x width B x height C mm
Note
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
≤ 25V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3 A
–
–
Green (version with LED)
–
–
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
90 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
2 x HE 10 connectors - 20 pole
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
≤ 25V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3 A
–
–
Green (version with LED)
–
–
2 x 24 V DC / LED yellow (for each 16-channel block)
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
145 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS 32ES H/V C 9445900000
RS 32ES-L H/V C 9445910000
C : compact version
Type Order No.
RS 32ES H/Z 9447900000 (1)
RS 32ES-L H/Z 9447910000
(1) on demand
C.29
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 32-channel digital I/O cardsSystem H
RS ES-S-I - 32 disconnectable channels
H System – 1-wireVersion: screw connecion
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
--
+F+
1820
1719
0.0 1
0.1 2
161.7I/O P
CB
Con
nect
orS
uppl
y V
olta
ge 1
FUS
I/O P
CB
Con
nect
or
2.0 1
2.1 2
163.7
--
+F+
1820
1719
Sup
ply
Vol
tage
2
FUS
Connector (1) H
E10/20 poles C
onnector (2) HE
10/20 poles
Disconnectableconnector
B
C
A
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
24 V DC ± 10%
1 A (*)
3 A
–
Yes - each channel
Green
–
–
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
220 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
Type Order No.
RS 32ES-S-I-L H/V 9445870000
C.30
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 32-channel digital I/O cardsSystem H
RS ES-D - 32-channel RS ES-D - 32-channel
H-System – 2-wire (common + or –)Version: screw connection - compact
H-System – 2-wire (common + or –)Version: tension clamp
C
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
--
+F+
1820
1719
0.0 1
0.1 2
161.7I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
-
+C
C
Shu
nt
1820
1719
I/O P
CB
Con
nect
or
2.0 1
2.1 2
163.7
C
C
C
Connector (1) H
E10/20 poles C
onnector (2) HE
10/20 polesB
C
A
--
+F+
1820
1719
0.0 1
0.1 2
161.7I/O P
CB
Con
nect
orS
uppl
y V
olta
ge 1
FUS
C
C
C
-
+C
C
Shu
nt
I/O P
CB
Con
nect
or
2.0 1
2.1 2
163.7
C
C
C
--
+F+
1820
1719
Sup
ply
Vol
tage
2
FUS
-
+C
C
Shu
nt
Connector (1) H
E10/20 poles C
onnector (2) HE
10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C C version mm
Length A x width B x height C mm
Note
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
24 V DC ± 10%
1 A (*)
3 A
–
–
Green
+ or – selectable with a jumper
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
170 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
2 x HE 10 connectors - 20 pole
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
24 V DC ± 10%
1 A (*)
3 A
–
–
Green
+ or – selectable with a jumper
3 A
2 x 24 V DC / LED yellow (for each 16-channel block)
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
230 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS 32ES-D-L H/V C 9445930000
C : compact version
Type Order No.
RS 32ES-D-L D/Z 9447930000
C.31
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 32-channel digital I/O cardsSystem H
RS ES-D-I - 32 disconnectable channels RS ES-D-I - 32 disconnectable channels
H-System – 2-wire (common + or –)Version: screw connection - compact
H-System – 2-wire (common + or –)Version: tension clamp
C
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
--
+F+
1820
1719
0.0 1
0.1 2
161.7I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
-
+C
C
Shu
nt
1820
1719
I/O P
CB
Con
nect
or
2.0 1
2.1 2
163.7
C
C
C
Connector (1) H
E10/20 poles C
onnector (2) HE
10/20 polesDisconnectable
connectorB
C
A
--
+F+
1820
1719
0.0 1
0.1 2
161.7I/O P
CB
Con
nect
orS
uppl
y V
olta
ge 1
FUS
C
C
C
-
+C
C
Shu
nt
I/O P
CB
Con
nect
or
2.0 1
2.1 2
163.7
C
C
C
--
+F+
1820
1719
Sup
ply
Vol
tage
2
FUS
-
+C
C
Shu
nt
Connector (1) H
E10/20 poles C
onnector (2) HE
10/20 poles
Disconnectableconnector
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C C version mm
Length A x width B x height C mm
Note
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
24 V DC ± 10%
1 A (*)
3 A
–
Yes - each channel
Green
+ or – selectable with a jumper
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
170 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
2 x HE 10 connectors - 20 pole
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
24 V DC ± 10%
1 A (*)
3 A
–
Yes - each channel
Green
+ or – selectable with a jumper
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
230 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS 32ES-D-I-L H/V C 9445950000
C : compact version
Type Order No.
RS 32ES-D-I-L H/Z 9447950000 (1)
(1) on demand
C.32
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 32-channel digital I/O cardsSystem H
RS ES-D-F - 32-channel with fuse
H-System – 2-wire (common + or –)Version: screw connection
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
--
+F+
1820
1719
0.0 1
0.1 2
161.7I/O P
CB
Con
nect
orS
uppl
y V
olta
ge 1
FUS
C
C
C
-
+C
C
Shu
nt
I/O P
CB
Con
nect
or
2.0 1
2.1 2
163.7
C
C
C
--
+F+
1820
1719
Sup
ply
Vol
tage
2
FUS
-
+C
C
Shu
ntFUS
FUS
FUS
FUS
FUS
FUS
Connector (1) H
E10/20 poles C
onnector (2) HE
10/20 polesB
C
A
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
≤ 25 V AC 50 V DC
1 A (*)
3 A
0.5 A fuse on each channel
–
–
+ or – selectable with a jumper
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
248 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
Type Order No.
RS 32ES-D-F H/V 9445980000
C.33
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 32-channel digital I/O cardsSystem H
RS ES-T - 32-channel RS ES-T - 32-channel
H System – 3-wire (common + and –)Version: screw connection - compact
H System – 3-wire (common + and –)Version: tension clamp
C
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
Dimensions
Ordering data
+F
1820
1719
0.0 1
0.1 2
161.7
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
1820
1719
I/O P
CB
Con
nect
or
2.0 1
2.1 2
163.7
--
+
+
+
+
+
-
-
-
+F
+
+
+
-
-
-
Connector (1) H
E10/20 poles C
onnector (2) HE
10/20 polesB
C
A
+F
1820
1719
0.0 1
0.1 2
161.7I/O P
CB
Con
nect
orS
uppl
y V
olta
ge 1
FUS
I/O P
CB
Con
nect
or
2.0 1
2.1 2
163.7
--
+
+
+
+
+
-
-
-
+F
+
+
+
-
-
-
+F
1820
1719
Sup
ply
Vol
tage
2FUS
--
++
+F
Connector (1) H
E10/20 poles
Connector (2) H
E10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C C version mm
Length A x width B x height C mm
Note
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3 A
–
–
Green (versions with LED)
+ and –
3 A
24 V DC / LED yellow
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
176 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
2 x HE 10 connectors - 20 pole
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
24 V DC ± 10%
1 A (*)
3 A
–
–
Green
+ and –
3 A
2 x 24 V DC / LED yellow (for each 16-channel block)
2 A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
221 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS 32ES-T H/V C 9445960000
RS 32ES-T-L H/V C 9445970000
C : compact version
Type Order No.
RS 16ES-T-L H/Z 9447970000
C.34
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 32-channel digital I/O cardsSystem R
RS ES - 32-channel RS ES-I – 32 disconnectable channels
System R – 1-wire cablingVersion: screw connection
System R – 1-wire cablingVersion: screw connection
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Note
Dimensions
Ordering data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
RSV 1.6 connector - 36 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3 A
–
–
–
–
–
max 150 V UC
2 A
–
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
148 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
RSV 1.6 connector - 36 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
250 V max
1 A (*)
3 A
–
Yes - each channel
–
–
–
max 250 V
2 A
3.15 A
250 V AC
III
2
1.7 KV DC
-25…50 ºC
-40…60 ºC
188 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS32ES RSV1,6/V 9441510000
Type Order No.
RS32ES-I RSV1,6/V 9441870000
C.35
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 32-channel digital I/O cardsSystem R
RS ES-DP - 32-channel RS ES-DP/F - 32-channel with fuse
R-System – 2-wire (common + or –)Version: screw connection
R-System – 2-wire (common + or –)Version: screw connection
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Note
Dimensions
Ordering data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
RSV 1.6 connector - 36 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3 A
–
–
–
+ or – selectable with a jumper
3 A
max 150 V UC
2 A
3.15 A
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
200 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Technical data
RSV 1.6 connector - 36 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3 A
1 A fuse on each channel
–
–
+ or – selectable with a jumper
3 A
max 150 V UC
2 A
3.15 A
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
200 x 109 x 84
(*) Observe the max. permissible current for the common wires
Type Order No.
RS32ES-DP RSV1,6/V 9441710000
Type Order No.
RS32ES-DP/F RSV1,6/V 9441570000 (1)
(1) on demand
C.36
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 32-channel digital I/O cardsSystem R
RS ES-3 E/I - 32 disconnectable channels
R System – 3-wire (common + and –)Version: screw connection
Direct inputs/outputs for digital cards
Screw connection without LED
Screw connection with LED
Note
Dimensions
Ordering data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
RSV 1.6 connector - 36 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3 A
–
Yes - each channel
–
+ and –
3 A
max 150 V UC
2 A
3.15 A
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
188 x 109 x 84
(*) Observe the max. permissible current for the common wires
Technical data
Type Order No.
RS32E-3E/I RSV1,6/V 9441610000
C.37
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
C V L O 9446900000 RS16E-OD 24-48V H/V C.39
C V L O 9446910000 (*) RS16E-OD 115 H/V C.40
C V L O 9446920000 (*) RS16E-OD 230V H/V C.40
Note: Preferably articles in bold (*) on demand
1 LED per chan.
Pluggableoptocoupler
Compact version
Connection
Screw Tension c.
Type
Order No. PageType
Functionalities Modules
16chan-nels
H System 2-wire
No. of channels
Type of wiring
H or R System
Module overview – Opto-decoupled inputs/outputs for digital cards
C.38
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
Pow
er supply
1
E1
Inpu
t PC
B C
onne
ctor
R
C1 C2
C1F
8
E8 RC1F
--
+
18
20
1719
Supply V
oltage
FUS
9
E9 R
C3 C4
C3F
16
E16 RC3F
+
FU
SF
US
Connector H
E10/20 poles
DimensionsSystem H – Pluggable optocouplersVersion: screw connection
For 16-channel digital cards RSE OD – 16-channel
A
C
BC
Opto-decoupled inputs for digital cards
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Operating Voltage
Input current AC
Input current DC
Switching voltage AC
Switching voltage DC
Max. switching current/voltage
Optocoupler polarisation voltage
Continuous current per optocoupler
Fuse (optocoupler power supply)
I/O card max. supply current
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C C version mm
Note
24-48 V version
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
24…48 V UC
9…21 mA AC
7…16 mA DC
20 V AC
19 V DC
100 mA / 48 V–
24 up to 48 V DC
100 mA
1 A
2 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
148 x 109 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS16E-OD 24-48V H/V C 9446900000
C : compact version
Technical data
Ordering data
AccessoriesNote Optocoupler - 4061180000
C.39
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
Opto-decoupled inputs for digital cards
1
E1
Inpu
t PC
B C
onne
ctor
R
C1 C2
C1F
8
E8 RC1F
--
+
18
20
1719
Supply V
oltage
FUS
9
E9 R
C3 C4
C3F
16
E16 RC3F
+
FU
SF
US
Connector H
E10/20 poles
DimensionsSystem H – Pluggable optocouplersVersion: screw connection
For 16-channel digital cards RSE OD – 16-channel
A
C
BC
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Operating Voltage
Input current AC
Input current DC
Switching voltage AC
Switching voltage DC
Max. switching current/voltage
Optocoupler polarisation voltage
Continuous current per optocoupler
Fuse (optocoupler power supply)
I/O card max. supply current
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C C version mm
Note
115 V version
230 V version
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
115 V UC / 230 V AC
7 mA AC / 7 mA AC
7 mA DC / –
80 V AC / 150 V AC
75 V DC / –
100 mA / 48 V–
24 up to 48 V DC
100 mA
1 A
2 A
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
148 x 109 x 72
(*) Observe the max. permissible current for the common wires
Type Order No.
RS16E-OD 115 H/V C 9446910000 (1)
RS16E-DO 230V H/V C 9446920000 (1)
C : compact version(1) on demand
Technical data
Ordering data
AccessoriesNote Optocoupler - 4061180000
C.40
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
C.41
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
C V 1CO 9445000000 RSM8C-1CO H/V C.43
C Z 1CO 9447000000 RSM8C-1CO H/Z C.43
C V 1CO 9445060000 (*) RSM12C-1CO H/V C.44
V 1CO 9444610000 RSM16-NV/1CO 24V (-/+) C.45
Z 1CO 9444660000 RSM16-NZ/1CO 24V (-/+) C.45
C V 1CO 9445100000 RSM16C-1CO H/V C.46
C Z 1CO 9447100000 RSM16C-1CO H/Z C.46
C V 1CO 1079390000 (*) RSM16 SLIM-1CO H/V C.47
C V 1CO 1094970000 (*) RSM16 SLIM-1CO H/V SOCKET C.47
V 2CO 9445160000 RSM16-2CO H/V C.48
C Z 2CO 9447160000 RSM16-2CO H/Z C.48
V 1CO P 9445140000 RSM16-1CO-Fo H/V C.49
V 1CO F 9445120000 RSM16-1CO-Fu H/V C.50
Z 1CO F 9447120000 RSM16-1CO-Fu H/Z C.50
V 1NO E 9445180000 RSM16 1T/Solen. ctrl 24V DC H/V C.51
C V 1CO 1108470000 (*) RSM32C-1CO 24VDC H/V C.52
C Z 1CO 9447200000 RSM32C-1CO H/Z C.52
V 1CO F 9445220000 RSM32-1CO-Fu H/V C.53
Note: Preferably articles in bold (*) on demand
8chan.
H System
H System
No. of channels
Type of contact
FuseForce
functionSolen. ctrl.Compact
version
Connection
Screw Tension c.
H or R System
Type
Order No. PageType
Functionalities Modules
H System
H System
12chan.
16chan-nels
32chan-nels
Module overview - Relay outputs for digital cards
C.42
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
--
+F+
18
20
1719
Sup
ply
Vol
tage
FUS
1
2
3
8
Relay 1
Relay 2
Relay 3
Relay 8
11
14
12
21
24
22
31
34
32
81
84
82
Out
put P
CB
Con
nect
or
Connector H
E10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
Screw connection
Tension clamp connection
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2 A
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
–
30 x 106 operations
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
110 x 109 x 68
(*) No main-circuits
Type Order No.
RSM8C-1CO H/V 9445000000
RSM8C-1CO H/Z 9447000000
Technical data
Ordering data
AccessoriesNote
Dimensions
For 8-channel digital output cards RSM-C – 8-channel
Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000
H System – 1CO relayVersions: screw / tension clamp
A
C
B
Relay outputs for digital cards
C.43
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
HE
10 20-pole connector
--
+F+
18
20
1719
Sup
ply
Vol
tage
FUS
1
2
3
12
Relay 1
Relay 2
Relay 3
Relay 12
11
14
12
21
24
22
31
34
32
121
124
122
Out
put P
CB
Con
nect
or
Connector H
E10/20 poles
Screw connection
Tension clamp connection
Note
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2 A
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
–
30 x 106 operations
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
147 x 109 x 68
(*) No main-circuits
Type Order No.
RSM12C-1CO H/V 9445060000
Technical data
Ordering data
AccessoriesNote
Dimensions
For 12-channel digital output cards RSM-C – 12-channel
Relay RCL314024 - 869326000 Static relay ODC - 8576340000Static relay OAC - 8576370000
H System – 1CO relayVersion: screw connection
A
C
B
Relay outputs for digital cards
C.44
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
COM
U
18
20
1719
Sup
ply
Vol
tage
1
2
3
16
Relay 1
Relay 2
Relay 3
Relay 16
11
14
12
21
24
22
31
34
32
161
164
162
Out
put P
CB
Con
nect
or
Input PC
B C
onnector
E1
E2
E3
E16
Connector H
E10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
Screw connection
Tension clamp connection
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
24 V ±10%
22 mA / 0.5 W
LED green
–
2 A
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
–
30 x 106 operations
250 V AC
III
2
1.2KVrms
-25…40 ºC
-40…60 ºC
267 x 87.5 x 68
(*) No main-circuits
Type Order No.
RSM16-NV/1CO 24V (-/+) 9444610000
RSM16-NZ/1CO 24V (-/+) 9444660000
Technical data
Ordering data
AccessoriesNote
Dimensions
For 16-channel digital output cards RSM-S – 16-channel
Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000
1CO relayVersions: screw / tension clamp
A
C
B
Relay outputs for digital cards
C.45
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
--
+F+
18
20
1719
Sup
ply
Vol
tage
FUS
1
2
3
16
Relay 1
Relay 2
Relay 3
Relay 16
11
14
12
21
24
22
31
34
32
161
164
162
Out
put P
CB
Con
nect
or
Connector H
E10/20 poles
Screw connection
Tension clamp connection
Note
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2 A
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
–
30 x 106 operations
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
185 x 109 x 68
(*) No main-circuits
Type Order No.
RSM16C-1CO H/V 9445100000
RSM16C-1CO H/Z 9447100000
Technical data
Ordering data
AccessoriesNote
Dimensions
For 16-channel digital output cards RSM-C – 16-channel
Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000
H System – 1CO relayVersions: screw / tension clamp
A
C
B
Relay outputs for digital cards
C.46
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
-
+
18
20
1719
Sup
ply
Vol
tage
1
2
3
16
Relay 1
Relay 2
Relay 3
Relay 16
11
14
12
21
24
22
31
34
32
161
164
162
Out
put P
CB
Con
nect
or
Connector H
E10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C C version mm
Note
Equipped with 1 CO relay screw connection
Empty slot, screw connection
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
24 V ±10%
8 mA / 0.2 W
LED green
–
2 A
1CO
1500 VA / 250 V AC
6 A version
4 A/6 A
AgSnO2
–
5 x 106 operations
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
111 x 87.5 x 85
(*) No main-circuits
Type Order No.
RSM16 SLIM-1CO H/V C 1079390000 (1)
RSM16 SLIM-1CO H/V SOCKET C 1094970000 (1)
C : compact version(1) on demand
Technical data
Ordering data
AccessoriesNote
Dimensions
For 16-channel digital output cards RSM SLIM – 16-channel
1CO relay - 4061590000Optocoupler ODC 24V/2A - 4061190000
H System – with 1CO relay / empty socketVersion: screw connection - compact
A
C
BC
Relay outputs for digital cards
C.47
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
--
+F+
18
20
1719
Sup
ply
Vol
tage
FUS
1
2
3
16
Relay 1
Relay 2
Relay 3
Relay 16
121
124
122
221
224
222
331
334
332
1621
1624
1622
Out
put P
CB
Con
nect
or
111
114
112
211
214
212
311
314
312
1611
1614
1612
Connector H
E10/20 poles
Screw connection
Tension clamp connection
Note
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2 A
2CO
2000 VA / 250 V AC
2x8 A version
4 A/8 A
AgNi 90/10
–
30 x 106 switching cycles
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
263 x 109 x 75
(*) No main-circuits
Type Order No.
RSM16-2CO H/V 9445160000
RSM16-2CO H/Z 9447160000
Technical data
Ordering data
AccessoriesNote
Dimensions
For 16-channel digital output cards RSM-2CO – 16-channel
2CO Relay - 4058570000
System H – 2CO relayVersions: screw / tension clamp
A
C
B
Relay outputs for digital cards
C.48
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
--
+F+
18
20
1719
Sup
ply
Vol
tage
FUS
1
2
3
16
Relay 2
Relay 3
Relay 16
11
14
12
21
24
22
31
34
32
161
164
162
Out
put P
CB
Con
nect
or
SW1
SW2
SW3
SW16
Switch
Connector H
E10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
Screw connection
Tension clamp connection
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2 A
1CO
3000 VA / 250 V AC
16 A version
2 A/16 A
AgNi 90/10
–
30 x 106 operations
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
263 x 109 x 75
(*) No main-circuits
Type Order No.
RSM16-1CO-Fo H/V 9445140000
Technical data
Ordering data
AccessoriesNote
Dimensions
For 16-channel digital output cards RSM-Fo - 16-channel with force function
Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000
H System – 1CO relayVersion: screw connection
A A
C
B
Relay outputs for digital cards
C.49
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
--
+F+
18
20
1719
Sup
ply
Vol
tage
FUS
1
2
3
16
Relay 1
Relay 2
Relay 3
Relay 16
11
14
12
21
24
22
31
34
32
161
164
162
Out
put P
CB
Con
nect
or FUS
FUS
FUS
FUS
Connector H
E10/20 poles
Screw connection
Tension clamp connection
Note
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.5...1.5 / 0.5...1.5 mm2 (AWG 16...26)
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2 A
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
5 A fuse on each channel
30 x 106 operations
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
261 x 109 x 75
(*) No main-circuits
Type Order No.
RSM16-1CO-Fu H/V 9445120000
RSM16-1RT-Fu H/Z 9447120000
Technical data
Ordering data
AccessoriesNote
Dimensions
For 16-channel digital output cards RSM-Fu – 16-channel with fuse
Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000
H System – 1CO relayVersions: screw / tension clamp
A A
C
B
Relay outputs for digital cards
C.50
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
--
+F+
18
20
1719
Sup
ply
Vol
tage
FUS
1
8
9
16
Relay 1
Relay 8
Relay 9
Relay 16
C1
C2
F1
Out
put P
CB
Con
nect
or
I1
F8
I8
C3
C4
F9
I9
F16
I16
FUS
FUS
FUS
FUS
Connector H
E10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
Screw connection
Tension clamp connection
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2 A
1CO
3000 VA / 250 V AC
16 A version
2 A/16 A
AgNi 90/10
–
30 x 106 operations
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
290 x 109 x 75
(*) No main-circuits
Type Order No.
RSM16 1T/Solen. ctrl. 24V DC H/V 9445180000
Technical data
Ordering data
AccessoriesNote
Dimensions
For 16-channel digital output cards RSM-Solen. ctrl. - 16-channel for solenoid
Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000
H System – 1O relayVersion: screw connection
A
C
B
Relay outputs for digital cards
C.51
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
--
+F+
18
20
1719
Sup
ply
Vol
tage
1
FUS
1
2
3
16
Relay 1
Relay 2
Relay 3
Relay 16
11
14
12
21
24
22
31
34
32
161
164
162
Out
put P
CB
Con
nect
or
--
+F+
18
20
1719
Sup
ply
Vol
tage
2
FUS
1
2
3
16
Relay 17
Relay 18
Relay 19
Relay 32
171
174
172
181
184
182
191
194
192
321
324
322
Out
put P
CB
Con
nect
or
Connector (1) H
E10/20 poles
Connector (2) H
E10/20 polesScrew connection
Tension clamp connection
Note
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
2 x HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2 A
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
–
30 x 106 operations
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
365 x 109 x 68
(*) No main-circuits
Type Order No.
RSM32C-1CO 24VDC H/V 1108470000(1)
RSM32C-1CO H/Z 9447200000
(1) on demand
Technical data
Ordering data
AccessoriesNote
Dimensions
For 32-channel digital output cards RSM-C – 32-channel
Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000
H System – 1 CO relayVersions: screw / tension clamp
A
C
B
Relay outputs for digital cards
C.52
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
--
+F+
18
20
1719
Sup
ply
Vol
tage
1
FUS
1
2
3
16
Relay 1
Relay 2
Relay 3
Relay 16
11
14
12
21
24
22
31
34
32
161
164
162
Out
put P
CB
Con
nect
or
--
+F+
18
20
1719
Sup
ply
Vol
tage
2
FUS
1
2
3
16
Relay 17
Relay 18
Relay 19
Relay 32
171
174
172
181
184
182
191
194
192
321
324
322
Out
put P
CB
Con
nect
orFUS
FUS
FUS
FUS
FUS
FUS
FUS
FUS
Connector (1) H
E10/20 poles
Connector (2) H
E10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
Screw connection
Tension clamp connection
Note
2 x HE 10 20-pole connectors
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2 A
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
5 A fuse on each channel
30 x 106 operations
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
511 x 109 x 75
(*) No main-circuits
Type Order No.
RSM32-1CO-Fu H/V 9445220000
Technical data
Ordering data
AccessoriesNote
Dimensions
For 32-channel digital cards RSM-Fu – 32-channel with fuse
Relay RCL314024 - 8693260000 Static relay ODC - 8576340000Static relay OAC - 8576370000
H System – 1 CO relayVersion: screw connection
A A
C
B
Relay outputs for digital cards
C.53
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
V M 9448000000 RS4AIO-DP SD/V C.55
V M I T 9448100000 RS4AIO/I-M-DP SD/V C.55
V M 9448010000 RS8AIO-DP SD/V C.56
V M I T 9448110000 RS8AIO/I-M-DP SD/V C.56
Z M I T 9449110000 RS8AIO/I-M-DP SD/Z C.56
V M I 9448030000 RS8AI PREM/APR SD/V C.57
V 9448040000 RS8E1AO MICRO SD/V C.57
V M 9448020000 RS16AIO-DP SD/V C.58
V M I T 9448120000 RS16AIO/I-M-DP SD/V C.58
Z M I T 9449120000 RS16AIO/I-M-DP SD/Z C.58
Note: Preferably articles in bold
Disconnec-table
Test points
Compact version
Connection
Screw Tension c.
Type
Order No. PageType
Functionalities Modules
4channels
Standard
8chan-nels
8channels P
Standard
16chan-nels
Standard
Premium(Télémécanique)
9channels M
Micro(Télémécanique)
Number of
channels
Common distribution
PLC
Module overview – Analogue input/output
C.54
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 4-channel analogue I/O cards RS AIO-DP - 4-channel RS AIO/I-M-DP - 4-channel
Common distributionVersion: screw connection
Common distribution, disconnection and testVersion: screw connection
Input / output for analogue cards
Screw connection
Tension clamp connection
Note
Dimensions
Ordering data
-
+F+
2
10
19
0+ 3
0- 11
1+ 4
1- 12
143-
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
63+
C
Shielded
ConnectorS
ubD 15 poles
B
C
A
Sub
Dm
ale
-
+F+
2
10
19
0+ 3
0- 11
1+ 4
1- 12
143-
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
63+
C
Shielded
Test point
Connector S
ubD 15 poles
Disconnectableconnector
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Number of channels
Operating voltage
Common distribution
PLC card supply current fuse
Disconnection
Current measuring test point
Voltage measuring test point
Continuous shielding
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
15-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
4
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
–
–
–
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
75 x 87.5 x 72
Technical data
15-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
4
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
Yes - each channel
Yes - 2 female testing points dia. 4 mm
Yes
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
73 x 109 x 81
Type Order No.
RS4AIO-DP SD/V 9448000000
Type Order No.
RS4AIO/I-M-DP SD/V 9448100000
C.55
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 8-channel analogue I/O cards RS AIO-DP - 8-channel RS AIO/I-M-DP - 8-channel
Common distributionVersion: screw connection
Common distribution, disconnection and testVersions: screw / tension clamp
Input / output for analogue cards
Screw connection
Tension clamp connection
Note
Dimensions
Ordering data
-
+F+
2
15
114
0+ 3
0- 16
1+ 4
1- 17
237-
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
107+
C
Shielded
Connector S
ubD 25 poles
B
C
A
Sub
Dm
ale
-
+F+
2
15
114
0+ 3
0- 16
1+ 4
1- 17
237-
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
107+
C
Shielded
Test point
Connector S
ubD 25 poles
Disconnectableconnector
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Number of channels
Operating voltage
Common distribution
PLC card supply current fuse
Disconnection
Current measuring test point
Voltage measuring test point
Continuous shielding
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
25-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
8
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
–
–
–
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
117 x 87.5 x 72
Technical data
25-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
8
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
Yes - each channel
Yes - 2 female testing points dia. 4 mm
Yes - 2 female testing points dia. 4 mm
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
114 x 109 x 81
Type Order No.
RS8AIO-DP SD/V 9448010000
Type Order No.
RS8AIO/I-M-DP SD/V 9448110000
RS8AIO/I-M-DP SD/Z 9449110000
C.56
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For Télémécanique Premium and Micro PLC analogue I/O cards
RS8AI PREM/APR – 8-channel RS8I1OA MICRO – 9-channel
8 analogue inputsVersion: screw connection
8 analogue inputs and 1 outputVersion: screw connection
Input / output for analogue cards
Screw connection
Tension clamp connection
Note
Dimensions
Ordering data
+
0+2
0- 14
1+
1- 3
127-
Inpu
t PC
B C
onne
ctor
C
C
C
C
+CS
hunt
7+
C
Shielded
1
Shunt
16
15
25
24
IC
IV
IC
IV
IC
IV
2+
2- 17
C
C
5
4
IC
IV
Connector S
ubD 25 poles
B
C
A
Sub
Dm
ale
E0+ 10
E0- 14
E2+ 11
E2-
E7-
I/O P
CB
Con
nect
or
6E7+
Shielded
S0+ 1
S0- 2
E1+ 3
E1-
10V
10V
10V
10V
10V
GND
GND
GND
GND
GND
15
Connector S
ubD 15 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Number of channels
Operating voltage
Common distribution
PLC card supply current fuse
Disconnection
Current measuring test point
Voltage measuring test point
Continuous shielding
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
25-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
8
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
–
Yes
–
–
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
116 x 87.5 x 72
Current/Voltage Switchable
Technical data
15-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
9
≤ 25 V AC 50 V DC
Shielding
–
–
–
Yes
Yes
< 50 V AC
II
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
100 x 87.5 x 72
Type Order No.
RS8AI PREM/APR SD/V 9448030000
Type Order No.
RS8I1OA MICRO SD/V 9448040000
C.57
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C
For 16-channel analogue I/O cards RS AIO-DP - 16-channel RS AIO/I-M-DP - 16-channel
Common distributionVersion: screw connection
Common distribution, disconnection and testVersion: screw / tension clamp
Input / output for analogue cards
Screw connection
Tension clamp connection
Note
Dimensions
Ordering data
-
+F+
2
21
120
0+ 3
0- 22
1+ 4
1- 23
3715-
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
1815+
C
Shielded
Connector S
ubD 37 poles
B
C
A
Sub
Dm
ale
-
+F+
2
21
120
0+ 3
0- 22
1+ 4
1- 23
3715-
I/O P
CB
Con
nect
orS
uppl
y V
olta
ge
FUS
C
C
C
C
-
+C
C
Shu
nt
1815+
C
Shielded
Disconnectableconnector
Test point
Connector S
ubD 37 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Number of channels
Operating voltage
Common distribution
PLC card supply current fuse
Disconnection
Current measuring test point
Voltage measuring test point
Continuous shielding
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C mm
Note
37-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
16
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
–
–
–
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
205 x 87.5 x 72
Technical data
37-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
16
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
Yes - each channel
Yes - 2 female testing points dia. 4 mm
Yes - 2 female testing points dia. 4 mm
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
197 x 109 x 81
Type Order No.
RS16AIO-DP SD/V 9448020000
Type Order No.
RS16AIO/I-M-DP SD/V 9448120000
RS16AIO/I-M-DP SD/Z 9449120000
C.58
PLC
Inte
rfac
esH
-, R
- an
d S
-Sys
tem
C