Envelope Compliance Certificate

Project Title:2012 IECC

Project Type: Addition

Permit No. P-0024695Vertical Glazing / Wall Area: 22%

Location: Leadville, ColoradoClimate Zone: 7

Construction Site: Owner/Agent: Designer/Contractor:

Project InformationEnergy Code:

GOL! Gear Library

Building Area Floor Area

1-School/university : Nonresidential 2794

Envelope Assemblies

Assembly CavityR-Value

Cont.R-Value

ProposedU-Factor

Budget U-Factor(a)

Gross Areaor

Perimeter

Roof 1: Insulation Entirely Above Deck, [Bldg. Use 1 - School/university] 2794 --- 30.0 0.032 0.028Exterior Wall 1: Wood-Framed, 16" o.c., [Bldg. Use 1 -School/university]

2167 13.0 7.5 0.051 0.051

Window 1: Metal Frame with Thermal Break:Fixed, Perf. Type: Energycode default, Single Pane, Clear , SHGC 0.80, [Bldg. Use 1 -School/university]

377 --- --- 1.100 0.290

Door 1: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Type:Energy code default, Single Pane, Clear , SHGC 0.80, [Bldg. Use 1 -School/university]

92 --- --- 1.200 0.770

Door 2: Insulated Metal, Non-Swinging, [Bldg. Use 1 - School/university] 100 --- --- 0.800 0.179Floor 1: Slab-On-Grade:Unheated, Horizontal with vertical >= 4 ft.,[Bldg. Use 1 - School/university] (b)

2794 --- 7.5 0.410 0.520

(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.(b) Slab-On-Grade proposed and budget U-factors shown in table are F-factors.

Envelope Compliance Statement

Envelope PASSES: Design 1% better than code

Interior Lighting Compliance Certificate

Project Title:2015 IECC

Project Type: Addition

Construction Site: Owner/Agent: Designer/Contractor:

Project InformationEnergy Code:

CMC Leadville

Allowed Interior Lighting PowerA

Area CategoryB

Floor Area(ft2)

CAllowed

Watts / ft2

DAllowed Watts

(B X C)

1-School/University 2794 0.87 24312431Total Allowed Watts =

Proposed Interior Lighting PowerE

(C X D)D

FixtureWatt.

AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast

BLamps/Fixture

C# of

Fixtures

1-School/UniversityUndercounter Light Fixture: L1: Other: 1 3 30 91Surface Mounted LED Strip Fixtur: L2 and L2E: Other: 1 3 15 4425" Wide Vanity Fixture: L3: Other: 1 2 20 404" Diamater LED Downlight: L4 and L4E: Other: 1 4 28 1108'-0" Long Linear LED Fixtue: L5E: Other: 1 2 100 20016'-0" Long Linear LED Fixture: L6, L6E and L7E: Other: 1 7 200 140024'-0" Long Linear LED Fixture: L8E: Other: 1 1 300 300Pendant Mounted Fixuture for Ent: L9 and L9E: Other: 1 3 65 195

2380Total Proposed Watts =

Interior Lighting Compliance Statement

Interior Lighting PASSES: Design 2% better than code

Mechanical Compliance Certificate

Project Title:2015 IECC

Project Type: Addition

Location: Denver, ColoradoClimate Zone: 5b

Construction Site: Owner/Agent: Designer/Contractor:

Project InformationEnergy Code:

CMC Leadville

Mechanical Systems ListQuantity System Type & Description

Heating: 1 each - Hydronic or Steam Coil, Hot Water, Capacity = 110 kBtu/h No minimum efficiency requirement appliesFan System: Unspecified

1 HVAC System 1 (Single Zone):

Gas Instantaneous Water Heater, Capacity: 0 gallons, Input Rating: 199 kBtu/h w/ Circulation Pump Proposed Efficiency: 0.81 EF, Required Efficiency: 0.62 EF

1 Water Heater 1:

Mechanical Compliance Statement

SCALE:1 MAIN LEVEL LIGHTING PLAN1/8" = 1'-0"SCALE:2 MEZZANINE LIGHTING PLAN

1/8" = 1'-0"

NOTES:

THE LIGHTING AND ASSOCIATED LIGHTING CONTROLS INTHIS SPACE SHALL BE PRICED AS ADD ALTERNATE #A1. IFTHIS ALTERNATES IS NOT ACCEPTED, THIS SPACE WILL BEOPEN TO ABOVE. REFER TO ARCHITECTURAL DRAWINGSFOR ADDITIONAL ALTERNATE INFORMATION ANDREQUIREMENTS.

CIRCUIT RESTROOM EXHAUST FAN WITH RESTROOMLIGHTING FOR ON/OFF CONTROL OF EXHAUST FAN.

DAYLIGHT ZONE.

FLAG NOTES:#

1.

1. CEILING MOUNTED OCCUPANCY SENSOR SHALL BEWATT-STOPPER #DT-305 DUAL TECHNOLOGYOCCUPANCY SENSOR. PROVIDE POWER PACKS ASREQUIRED. THE LOWER CASE LETTER NEXT TOOCCUPANCY SENSORS INDICATE SWITCHINGFUNCTION CEILING MOUNTED OCCUPANCY SENSORSHALL CONTROL.

2. THE LOWER CASE LETTERS NEXT TO LIGHT FIXTURESINDICATES SWITCHING FUNCTION FOR LIGHTFIXTURE. THE LOWER CASE LETTERS NEXT TOSWITCHES INDICATE LIGHT FIXTURES LIGHTINGCONTROL DEVICE SHALL CONTROL.

3. THE NUMBERS NEXT TO ELECTRICAL DEVICESINDICATE THE CIRCUIT POSITION THAT THE BRANCHCIRCUIT SHALL OCCUPY IN PANEL "D" UNLESS NOTEDOTHERWISE.

4. ALL DIMMERS SHALL BE LUTRON #DVSTV UNLESSNOTED OTHERWISE.

5. ALL CONDUIT IN EXPOSED AREAS SHALL BE EMT ANDSHALL BE PAINTED TO MATCH SURROUNDINGSURFACES.

L1

L1

L2E

L1

SO

SO

L3

L4

L4

L3b

OS

L4E

b,c

bL4

c

SO

L2

X1

X1

X1

OS

OS

DL

DLOS

D

D

S3

S 4

D

S3

S3

DL

L7E L7EL6E

L5E

L9

L9

L9E

L5E

L6E L6

L6

L8EL7E

X2

X2

X2

X2

2.

2

L2

SO

OS

OS

OS

OS

S4

TO UPPER LEVELLIGHTING TO UPPER LEVEL

LIGHTING

TO UPPER LEVELLIGHTING

TO UPPER LEVELLIGHTING

a,i

aa

a,f

a,ha,h

a,i

e

e

e

e

e

OSeTO LOWER LEVELLIGHTING CONTROL

S3b

S3

b

b

TO LOWER LEVELLIGHTING CONTROL Sc

Db

S3b

d

d

dd

d

2

2 TO UPPER LEVELLIGHTING

f

fSf

a,f

a,f

a,f

a

a

a

9

11

d d

TO UPPER LEVELLIGHTING

g

g g

g

gOS a,f

OS g

333

3

3

3.

DL h

DL i

1

1

S:\B

GPR

OJE

CTS

\995

6.00

CM

C L

EAD

VILL

E - G

OL

EXPA

NSI

ON

\DR

AWIN

GS\

9956

.00_

EL21

.DW

G

ISSUE DESCRIPTIONDATE

architecturalaw

WORKSHOP

LEADERSHIP CENTER

GEAR LIBRARYCLIMAX MOLYBDENUM

ALBUQUERQUE | AVON | DENVER | FORT COLLINS

303.278.3820 www˛bgbuildingworks˛comProject No. 9956.00 Copyright 2018

1

MAIN LEVEL ANDMEZZANINE LEVELLIGHTING PLANS

EL2.1