1TSE-N / A.S. February 2002

EWM 1000

COMPONENTFUNCTIONALITY

2TSE-N / A.S. February 2002

EWM 1000Electronic control

3TSE-N / A.S. February 2002

EWM 1000Electronic control

programme selectorwith mains switch

heating relay

mains supply

motor triacwith heat sink

motor relays:2 reversing1 field tap

microprocessor

secondaryselector

4TSE-N / A.S. February 2002

EWM 1000Electronic control

ROM RAM EEPROMExternal

asynchronousserial interface

µP

Internal synchronous serial interface

Power failureand machine

status

Machineconfiguration

CycledescriptionFirmware,

can’t bemodified onproduction

boards

Programmevariables,

erasedwhen

appliance isswitched off

5TSE-N / A.S. February 2002

EWM 1000Spare Part Circuit Boards

Ø Configuration file contains machine ident- ification, hence is different each PNC/ELC

Ø A CB configured for another PNC/ELC can’t be used for replacement !

Ø At the present stage, CBs are not config- urable in field service

Ø CBs ordered for a specific PNC/ELC will be configured prior to delivery by the spares warehouse, or, in a next phase, by the service centre

6TSE-N / A.S. February 2002

Inputs & sensors

The electronic control accepts inputs from :

Ø user interface (rotary selectors & pushbuttons)

Ø door lock

Ø pressure switches with 2 or 3 levels

Ø NTC sensor

Ø tachogenerator

ØDSP reed switch on top-loaded machines

7TSE-N / A.S. February 2002

Outputs to actuators

The electronic control generates (power)outputs to the following indicators andactuators:

Ø user interface (indicator LEDs and buzzer)

Ø main motor (speed control, reversing & field tapping)

Ø drain pump motor

Ø 2 solenoid valves

Ø door lock

Ø door lock indicator lamp (some models)

8TSE-N / A.S. February 2002

Circuit diagram (single field coil)Machines up to 1200 rpm

9TSE-N / A.S. February 2002

Circuit diagram (split field)Machines with 1400 rpm

10TSE-N / A.S. February 2002

Wiring

11TSE-N / A.S. February 2002

Door Lock Bimetal PTC type

1. EWM 1000 circuit board10. Door lock11. Interference filter12. Door lock indicator lamp (optional)ON/OFF Main switchintegrated in programmeselector

Triac powers bimetalPTC, which deformesunder heat, and locksdoor

12TSE-N / A.S. February 2002

Door Lock Instantaneous type

1. EWM 1000 circuit board10. Door lock11. Interference filter12. Door lock indicator lamp (optional)ON/OFF Main switchintegrated in programmeselector

Triac sends to solenoid:1 pulse to lock2 pulses to unlock

13TSE-N / A.S. February 2002

Door Lock Instantaneous type

14TSE-N / A.S. February 2002

Door Lock Instantaneous type

2-3 approx. 1.2 kΩ2-4 approx. 1.0 kΩ3-4 approx. 190 Ω

15TSE-N / A.S. February 2002

Door Lock Instantaneous type

16TSE-N / A.S. February 2002

Detergent dispenser(short version)

1. water fill hose 2. gasket 3. strain relief for supply cable 4. valve support 5. 2-way inlet valve (cold water) 7. tubes 8. inlet piece 9. cover with water channels10. detergent dispenser11. vapour outlet12. detergent drawer13. siphon14. detergent fill tube

17TSE-N / A.S. February 2002

Detergent dispenser(short version)

with 3 compartments:a prewashb main wash

d fabric softener

with 4 compartments:a prewashb main washc bleachd fabric softener

18TSE-N / A.S. February 2002

Detergent dispenser(long version)

1. water fill hose 2. gasket 3. strain relief for supply cable 4. valve support 5. 2-way inlet valve (cold water) 7. tubes 8. inlet piece 9. cover with water channels10. detergent dispenser11. vapour outlet12. detergent drawer13. siphon14. detergent fill tube

19TSE-N / A.S. February 2002

Detergent dispenser(long version)

with 3 compartments:a prewashb main wash

d fabric softener

with 4 compartments:a prewashb main washc bleachd fabric softener

20TSE-N / A.S. February 2002

Water fill: prewash(on 3-compartment dispensers)

If the prewash solenoid valve is energized,water flows into the prewash compartment.

With the STAINS option (can’t be selectedsimultaneously with PREWASH), the com-

partment will be used for the stain remover.

21TSE-N / A.S. February 2002

Water fill: main wash(on all dispensers)

If the main wash solenoid valve is energized,water flows into the main wash compartment

22TSE-N / A.S. February 2002

Water fill: fabric conditioner(on all dispensers)

If both solenoid valves are energized,the jets deviate each other, and

water flows through the middle channelinto the fabric conditioner compartment

23TSE-N / A.S. February 2002

Water fill: prewash and bleach(on 4-compartment dispensers)

The prewash solenoid valve is energized, andwater flows both into the prewash, and into

the bleach compartment

This means that the PREWASH and BLEACHoptions can’t be selected simultaneously !

Stains

24TSE-N / A.S. February 2002

Pressure switch

25TSE-N / A.S. February 2002

Pressure switch

11 - 14 (NO)Antiboil / foam level

21 - 24 (NO)“1st” level

31 - 32 (NC !)Antiflood levelNOT ON ALLMODELS !!

Drum G20 (46 l)Eco-ball

Drum G19 (42 l)Traditional/ Eco-ball

Full (mm) Refill (mm) Full (mm) Refill (mm)Antiboil level 55± 3 35± 3 55± 3 35± 3“1st” level 80± 3 55± 3 90± 3 70± 3Antiflood level 390± 15 240±50 390± 15 240±50

26TSE-N / A.S. February 2002

Water fill control

1. EWM 1000 PCB2. Pressure switch antiboil/foam level3. Pressure switch “1st“ level4. Prewash solenoid valve5. Main wash solenoid valve6. Heating elementAB_S Antiboil level sensingL1_S “1st“ level sensing

27TSE-N / A.S. February 2002

Water Fill Control

Øin the first fill step, water is filled until antiboil, and then “1st“ level contacts close

Øthe electronic measures the time ∆t elapsed between closure of antiboil and “1st“ level contacts, and calculates the flow rate = volume AB to L1 / ∆t

Øin the second fill step, an additional quant- ity defined in the programme tables is filled

Øthis fill step is time controlled, based on the flow rate

28TSE-N / A.S. February 2002

Antiflood Protection(not on all models)

1. EWM 1000 PCB8. Drain pump9. Pressure switch antiflood levelHV1_S Antiflood level sensingDrain_TY_S Drain pump triac sensing

AF pressure switch isnormally closed.If it opens, drain pumpis activated until theswitch closes again

29TSE-N / A.S. February 2002

Drain Control

1. EWM 1000 PCB2. Pressure switch antiboil level8. Drain pumpAB_S Antiboil level sensingDrain_TY_S Drain pump triac sensing

First drain phase untilAB pressure switchopens on “empty”.Second drain phasetime-controlled.

30TSE-N / A.S. February 2002

Heating Control

1. EWM 1000 PCB2. Pressure switch antiboil level3. Pressure switch “1st“ level6. Heating element7. NTC sensorK1 Heating relay on PCBAB_S Antiboil level sensingL1_S “1st“ level sensing

NTC sensor nowintegrated in heatingelement !

31TSE-N / A.S. February 2002

NTC characteristic

32TSE-N / A.S. February 2002

Brush Motor

33TSE-N / A.S. February 2002

Motors

34TSE-N / A.S. February 2002

Motor control

1. EWM 1000 PCB2. Pressure switch antiboil level13. Motor

M = RotorS = StatorP = ProtectionT =Tachogenerator

AB_S Antiboil level sensing

35TSE-N / A.S. February 2002

FUCSFast Unbalance Control System

Balance after first attempt

FUCSphase 0

FUCSphase 1

Normalspin

470 rpmpulse

55 rpm

115 rpm

In this phasespeed isincreased by2 rpm every300 ms ifunbalancebelow limit,

or decreasedby 2 rpm ifunbalance isabove limit.

36TSE-N / A.S. February 2002

FUCSFast Unbalance Control System

Balance after second attempt

FUCSphase 0

FUCSphase 1

Normalspin

FUCSphase 2

37TSE-N / A.S. February 2002

FUCSFast Unbalance Control System

Balance after third phase, normal spin

FUCSphase

0

Normalspin

FUCSphase

2

FUCSphase

1

FUCSphase

3

FUCSphase

2

FUCSphase

1

FUCSphase

3

38TSE-N / A.S. February 2002

FUCSFast Unbalance Control System

Some unbalance after third phase, reduced spin

FUCSphase

0

Red.spin

FUCSphase

2

FUCSphase

1

FUCSphase

3

FUCSphase

2

FUCSphase

1

FUCSphase

3

39TSE-N / A.S. February 2002

FUCSFast Unbalance Control System

Unbalance after third phase, no spin

FUCSphase

0

Nospin

FUCSphase

2

FUCSphase

1

FUCSphase

3

FUCSphase

2

FUCSphase

1

FUCSphase

3

40TSE-N / A.S. February 2002

Foam controlSpin with some foam

Spin without foam Spin with some foam

AB level on “full”, spin discontinued with drainpump operating, until AB returns to “empty”.

Spin phase skipped after 5 attempts.