EXISTINGELEVATION

STORMSEWER

INVERTS

SANITARYSEWER

INVERTS

CHAINAGE

85.0

6

72.9

2

72.2

3

72.2

9

70.2

8

0+00

0

0+02

5

0+05

0

0+07

5

0+09

0

PROVIDE ONE ALUMINIUM SAFETYPLATFORM INSIDE THE MAINTENANCEHOLE AS PER OPSD 404.02

100mm THICKHI-40 INSULATION

SE

(DR

OP

)=7

0.98 15.95m - 200mmØ SAN @ 1.0%15.09m - 200mmØ SAN @ 2.6%8.15m - 200mmØ SAN @ 6.0% 28.06m - 200mmØ SAN @ 1.0%

SE

(DR

OP

)=7

0.98

PROVIDE EXTERNALDROP PIPE AS PER

OPSD 1003.020

PROVIDE 11.0m -500mmØ STEEL SLEEVE

EXISTING CONCRETERETAINING WALL

EXISTING STONERETAINING WALL

NW

=70.

95E

=74.

810+

019.

75 S

AN

MH

NE

=70.

06S

E=7

0.55

0+03

5.15

SA

NM

H

NE

=69.

89S

W=6

9.90

0+05

2.62

SA

NM

H

SW

=69.

61N

=69.

56S

=69.

570+

080.

68 S

AN

MH

SA

NM

H 1

T/G

=72.

04

SA

NM

H 2

T/G

=71.

95

SA

NM

H 3

T/G

=72.

40

SA

NM

H 4

T/G

=76.

97

NE

=69.

42S

=69.

500+

086.

16 S

AN

MH

SA

NM

H E

XT/

G=7

0.54

5.85m - 250mØCOMB @ 1.0%

4.45m - 250mØSTM @ 1.0%

SAN CAPINV.=75.30

EX 250mmØCOMBINEDOUTLETSEWER

EX 150mmØSANITARYSEWER

PL

PL

SW

=69.

68N

E=6

9.67

0+07

6.61

STM

MH

22.56m -250mmØ STM

@1.0%

SW

=69.

92N

E=6

9.91

0+05

4.06

STM

MH

18.96m -250mmØ STM

@1.0%

SE

=70.

48N

E=7

0.11

0+03

5.89

STM

MH

E=7

4.60

NW

=70.

950+

020.

86 S

TMM

H

21.15m -250mmØ STM

@6.0%

15.70m -250mmØ STM

@3.0%

STM

MH

4T/

G=7

6.45

STM

MH

3T/

G=7

2.32

STM

MH

2T/

G=7

1.92

STM

MH

1T/

G=7

2.20

LEVEL 00=79.45m

LOW USF=77.45m

USF=VARIES

CA

P=7

5.30

PROPOSED BUILDING

SA

NIT

AR

YS

ER

VIC

E

ICD

X

X

X

X

X

X

RD 4

0+000

2.0m1.5m

2.0m

5.5m

2.0m

8.2m-200mmØ SAN @ 6.0% 15.1m-200mmØ SAN @ 2.6%

15.9

m-2

00m

SA

N @

1.0

%

SANMH 4T/G=76.97INV.NW=70.95INV.E=74.81

SANMH 3T/G=72.34

INV.NE=70.06INV.SE=70.55

SAN INV.=75.30

STMMH Proposed Storm Sewer-74T/G=???INV.W=75.87

STMMH 4T/G=76.45

INV.NW=70.95INV.E=74.60

21.2m-250mmØ STM @ 6.0%

STMMH 3T/G=72.32

INV.NE=70.11INV.SE=70.48

15.7m-250mmØ STM @ 3.0%

19.0

m-2

50m

STM

@ 1

.0%INV.SE (DROP)

=70.98

INV.SE(DROP)=70.98

RE

INS

TATE

ALL D

ISTU

RB

ED

AR

EA

STO

EX

ISTIN

G C

ON

DITIO

NS

OR

BE

TTER

, TO TH

E S

ATIS

FAC

TION

OF

THE

EN

GIN

EE

R A

ND

THE

OW

NE

R

REINSTATE ALL DISTURBED AREASTO EXISTING CONDITIONS OR

BETTER, TO THE SATISFACTION OFTHE ENGINEER AND THE OWNER

MAINTAIN AND PROTECT ALL EXISTINGMUNICIPAL INFRASTRUCTURE WITHIN

THE R.O.W. AT ALL TIMES

PROPOSED SERVICINGEASEMENT

0+09

0

0+050

2.0m1.5m2.0m

5.5m

5.7m PL to Bldg

15.1

m-2

00m

SA

N @

2.6

%

15.9m-200mmØ SAN @ 1.0%28.1m-200mmØ SAN @ -1.0%

SANMH 3T/G=72.34INV.NE=70.06INV.SE=70.55

SANMH 2T/G=72.04

INV.NE=69.89INV.SW=69.90 SANMH 1

T/G=72.16INV.SW=69.61INV.N=69.56INV.S=69.57

5.9m-250mØCOMB @ 1.03%4.5m-250mØ STM@ 1.0% 3.0m

STMMH 3T/G=72.32

INV.NE=70.11INV.SE=70.48

15.7

m-2

50m

STM

@ 3

.0%

STMMH 2T/G=71.82

INV.NE=69.91INV.SW=69.92

19.0m-250mmØ STM @ 1.0% STMMH 1T/G=71.96

INV.NE=69.67INV.SW=69.68

22.6m-250mmØ STM @ 1.0%

PROVIDE 100mm THICKHI-40 INSULATION

REINSTATE ALL DISTURBED AREASTO EXISTING CONDITIONS OR

BETTER, TO THE SATISFACTION OFTHE ENGINEER AND THE OWNER

(250Ø COMB.) (250Ø STORM) (200Ø SAN)INV.S=69.57 (150Ø EX. SAN)

PROVIDE 45° LONGRADIUS BEND

5.9m - 250mmØ PVCDR35 COMBINED @ 1.0%

CONNECT TO EXISTING COMBINED MANHOLE WITH NEW 250mmØ PVC SEWER FROMTHE SOUTH. EXISTING INVERT=69.50±. PROPOSED INVERT AT CONNECTION=69.50±.

MAINTAIN AND PROTECT EXISTING STRUCTURE AND THE COMBINED OUTLETSEWER TO THE NORTH-EAST. CONTRACTOR TO CONFIRM EXACT ELEVATION OF

SEWER PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES.ROAD CUT REINSTATEMENT AS PER CITY OF OTTAWA STANDARD R10.

CONNECT TO EXISTING 150mmØ PVC SANITARYSEWER WITH SAN MH 1. EXISTING INVERT=69.57±.

MAINTAIN AND PROTECT EXISTING SANITARY SERVICETO THE SOUTH. CONTRACTOR TO CONFIRM EXACT

ELEVATION OF SEWER PRIOR TO CONSTRUCTION ANDNOTIFY ENGINEER OF ANY DISCREPANCIES.

MAINTAIN AND PROTECT ALL EXISTINGMUNICIPAL INFRASTRUCTURE WITHIN

THE R.O.W. AT ALL TIMESMAINTAIN AND PROTECT ALL EXISTINGMUNICIPAL INFRASTRUCTURE WITHIN

THE R.O.W. AT ALL TIMES

MU

NIC

IPA

L IN

FRA

STR

UC

TUR

E W

ITH

INTH

E R

.O.W

. AT

ALL

TIM

ES

PROPOSED SERVICING EASEMENT

PROPOSED

SERVICIN

G

EASEMENT

PR

OP

OS

ED

SE

RV

ICIN

GE

AS

EM

EN

T

OUTLET SEWERPLAN AND PROFILE

CITY OF OTTAWA593 LAURIER AVENUE / 140 BRONSON AVENUE

119019

REV # 1

119019-P1

MS

MS

BF

MS

MS

M:\2

019\

1190

19\C

AD

\Des

ign\

1190

19-P

P.d

wg,

PP

, Dec

06,

201

9 - 2

:24p

m, s

mat

thew

s

PLANA1.DWG - 841mmx594mm

NOTE:THE POSITION OF ALL POLE LINES, CONDUITS,WATERMAINS, SEWERS AND OTHERUNDERGROUND AND OVERGROUND UTILITIES ANDSTRUCTURES IS NOT NECESSARILY SHOWN ONTHE CONTRACT DRAWINGS, AND WHERE SHOWN,THE ACCURACY OF THE POSITION OF SUCHUTILITIES AND STRUCTURES IS NOT GUARANTEED.BEFORE STARTING WORK, DETERMINE THE EXACTLOCATION OF ALL SUCH UTILITIES ANDSTRUCTURES AND ASSUME ALL LIABILITY FORDAMAGE TO THEM.

PROJECT No.

REV

DRAWING No.

DRAWING NAME

LOCATION

No. REVISION DATE BY

FOR REVIEW ONLYSCALE

APPROVED

CHECKED

DRAWN

CHECKED

DESIGN

Engineers, Planners & Landscape Architects

Suite 200, 240 Michael Cowpland Drive

Ottawa, Ontario, Canada K2M 1P6

Telephone (613) 254-9643

Facsimile (613) 254-5867

Website www.novatech-eng.com

N.T.S.KEY PLAN

601:150

42

SEE ADJACENT FOR CONTINUATION

STA 0+029

STA 0+060

SITECOMMISSIONER

LOR

NE AV

ST

BOO

TH ST

BROAD ST

FLEET ST

WELL

INGTO

NST

ALBERT ST

COOPER ST

GLOUCESTER STLAURIER AV

LISGAR ST

LYON ST NNEPEAN ST

SLATER ST

SOMERSET ST

ARTHUR ST

BRO

NSO

N AV

CAMBRIDG

E ST N

EMPRESS

BRICKHILL

PERKIN

S

PRIMROSE AV

ST

EMPR

ESS

AV

AV

ST

QUEEN ST

BAY ST

PERCY ST

GILMOUR STMACLAREN ST

LETT ST

LLOYD ST

WEL

LING

TON

ST

MH-COMBEXISTING COMBINED MH & SEWER

PROPOSED SANITARY MANHOLE AND SEWER

LEGENDSAN MH

PROPOSED STORM MANHOLE AND SEWER STM MH

SEWER NOTES:1. SUPPLY AND CONSTRUCT ALL SEWERS AND APPURTENANCES IN ACCORDANCE WITH THE MOST

CURRENT CITY OF OTTAWA STANDARDS AND SPECIFICATIONS.

2. SPECIFICATIONS:ITEM SPEC. No. REFERENCESTORM / SANITARY MANHOLE (1200mmØ) 701.010 OPSDSTORM / SANITARY MH FRAME & COVER 401.010 OPSDWATERTIGHT MH FRAME AND COVER 401.030 OPSDSEWER TRENCH S6 CITY OF OTTAWASANITARY / STORM SEWER PVC DR 35

3. ALL STORM AND SANITARY SERVICE LATERALS SHALL BE EQUIPPED WITH BACKFLOW PREVENTIONDEVICES AS PER THE CITY OF OTTAWA STANDARD DETAILS S14 AND S14.1 OR S14.2.

4. INSULATE ALL PIPES (SAN/STM) THAT HAVE LESS THAN 1.5m COVER WITH HI-40 INSULATION PERINSULATION DETAIL FOR SHALLOW SEWERS. PROVIDE 150mm CLEARANCE BETWEEN PIPE ANDINSULATION.

5. SERVICES ARE TO BE CONSTRUCTED TO 1.0m FROM FACE OF BUILDING AT A MINIMUM SLOPE OF1.0%.

6. PIPE BEDDING, COVER AND BACKFILL ARE TO BE COMPACTED TO AT LEAST 95% OF THE STANDARDPROCTOR MAXIMUM DRY DENSITY. THE USE OF CLEAR CRUSHED STONE AS A BEDDING LAYER SHALLNOT BE PERMITTED.

7. FLEXIBLE CONNECTIONS ARE REQUIRED FOR CONNECTING PIPES TO MANHOLES (FOR EXAMPLEKOR-N-SEAL, PSX: POSITIVE SEAL AND DURASEAL). THE CONCRETE CRADLE FOR THE PIPE CAN BEELIMINATED.

8. THE OWNER SHALL REQUIRE THAT THE SITE SERVICING CONTRACTOR PERFORM FIELD TESTS FORQUALITY CONTROL OF ALL SANITARY SEWERS. LEAKAGE TESTING SHALL BE COMPLETED INACCORDANCE WITH OPSS 410.07.16, 410.07.16.04 AND 407.07.24. DYE TESTING IS TO BE COMPLETEDON ALL SANITARY SERVICES TO CONFIRM PROPER CONNECTION TO THE SANITARY SEWER MAIN.THE FIELD TESTS SHALL BE PERFORMED IN THE PRESENCE OF A CERTIFIED PROFESSIONALENGINEER WHO SHALL SUBMIT A CERTIFIED COPY OF THE TEST RESULTS.

9. ALL STORM MANHOLES AND CATCHBASIN MANHOLES ARE TO HAVE 300mm SUMPS UNLESSOTHERWISE INDICATED. ALL CATCHBASINS ARE TO HAVE 600mm SUMPS UNLESS OTHERWISEINDICATED.

10. ALL CATCHBASINS, MANHOLES AND/OR CATCHBASIN MANHOLES THAT ARE TO HAVE ICD's INSTALLEDWITHIN THEM ARE TO HAVE 600mm SUMPS.

11. ALL WEEPING TILE CONNECTIONS TO BE MADE TO THE PROPOSED STORM SEWER SYSTEMDOWNSTREAM OF ANY INLET CONTROL DEVICES.

12. THE CONTRACTOR IS TO TELEVISE (CCTV) ALL PROPOSED SEWERS, 200mmØ OR GREATER PRIOR TOBASE COURSE ASPHALT. UPON COMPLETION OF CONTRACT, THE CONTRACTOR IS RESPONSIBLE TOFLUSH AND CLEAN ALL SEWERS & APPURTENANCES.

13. CONTRACTOR TO PROVIDE THE CONSULTANT WITH A PLAN AND PROFILE DRAWING INDICATING ALLAPPLICABLE SERVICING AS-BUILT INFORMATION SHOWN ON THIS PLAN. AS-BUILT INFORMATIONMUST INCLUDE: PIPE MATERIAL, SIZES, LENGTHS, SLOPES, INVERT AND T/G ELEVATIONS,STRUCTURE LOCATIONS AND ANY ALIGNMENT CHANGES, ETC.

GENERAL NOTES:1. COORDINATE AND SCHEDULE ALL WORK WITH OTHER TRADES AND CONTRACTORS.

2. DETERMINE THE EXACT LOCATION, SIZE, MATERIAL AND ELEVATION OF ALL EXISTING UTILITIESPRIOR TO COMMENCING CONSTRUCTION. PROTECT AND ASSUME RESPONSIBILITY FOR ALLEXISTING UTILITIES WHETHER OR NOT SHOWN ON THIS DRAWING.

3. OBTAIN ALL NECESSARY PERMITS AND APPROVALS FROM THE CITY OF OTTAWA BEFORECOMMENCING CONSTRUCTION.

4. BEFORE COMMENCING CONSTRUCTION OBTAIN AND PROVIDE PROOF OF COMPREHENSIVE, ALL RISKAND OPERATIONAL LIABILITY INSURANCE FOR $5,000,000.00. INSURANCE POLICY TO NAME OWNERS,ENGINEERS AND ARCHITECTS AS CO-INSURED.

5. RESTORE ALL DISTURBED AREAS ON-SITE AND OFF-SITE, INCLUDING TRENCHES AND SURFACES ONPUBLIC ROAD ALLOWANCES TO EXISTING CONDITIONS OR BETTER TO THE SATISFACTION OF THECITY OF OTTAWA AND ENGINEER.

6. REMOVE FROM SITE ALL EXCESS EXCAVATED MATERIAL, ORGANIC MATERIAL AND DEBRIS UNLESSOTHERWISE INSTRUCTED BY ENGINEER. EXCAVATE AND REMOVE FROM SITE ANY CONTAMINATEDMATERIAL. ALL CONTAMINATED MATERIAL SHALL BE DISPOSED OF AT A LICENSED LANDFILLFACILITY.

7. ALL ELEVATIONS ARE GEODETIC.

8. REFER TO GEOTECHNICAL REPORT (No. 190227, DATED JUNE, 2019), PREPARED BY LRL ENGINEERINGFOR SUBSURFACE CONDITIONS, CONSTRUCTION RECOMMENDATIONS, AND GEOTECHNICALINSPECTION REQUIREMENTS. THE GEOTECHNICAL CONSULTANT IS TO REVIEW ON-SITE CONDITIONSAFTER EXCAVATION PRIOR TO PLACEMENT OF THE GRANULAR MATERIAL.

9. REFER TO ARCHITECT'S AND LANDSCAPE ARCHITECT'S DRAWINGS FOR BUILDING AND HARDSURFACE AREAS AND DIMENSIONS.

10. REFER TO DEVELOPMENT SERVICING & STORMWATER MANAGEMENT REPORT (R-2019-193)PREPARED BY NOVATECH.

11. SAW CUT AND KEY GRIND ASPHALT AT ALL ROAD CUTS AND ASPHALT TIE IN POINTS AS PER CITY OFOTTAWA STANDARDS (R10).

301:75

21

D07

-12-

19-_

___

CITY PLAN #_______-P1

REFER TO PLAN 119019-GP FORCONTINUATION OF ON-SITE SEWERS

SEE ADJACENT FOR CONTINUATION

1 ISSUED FOR SITE PLAN APPROVAL DEC 9/19 MS

EXISTING CONCRETE CURB

EXISTING HYDRANT & VALVEHYD V&VB

EXISTING UTILITY POLE EX UP

EXISTING FENCE

EXISTING TREES / VEGETATION

300mmØ WM

SANMH EXISTING SANITARY MANHOLE & SEWER

EXISTING WATERMAIN

EXISTING HYDRANT HYD

EXISTING OVERHEAD WIRES

REFER TO PLAN119019-GP FOR DETAILS

OF ON-SITE SEWERS

593 LAURIER AVENUE WEST 140 BRONSON AVENUE

140 BRONSON AVENUE

OWNER INFORMATIONALEXANDER FLECK HOUSE INC.

250 STE ANNE AVENUE,OTTAWA, ONTARIO, K1L 7C4

DENIS MICHAUDPHONE: (613) 402-2855

denis@henryinvestments.ca