A Low Cost Bidirectional Human-Computer Interface Authors: Alexey Borisenko, Lukash Monczak, Ikvir S...

Post on 12-Jan-2016

217 views 0 download

Tags:

transcript

A Low Cost Bidirectional Human-Computer Interface

Authors: Alexey Borisenko, Lukash Monczak, Ikvir S Samra, Ovidiu Draghici, Daniel Shapiro, Voicu Groza

Overview

Objectives Motivation Neuroplasticity HCI state-of-art Approach Results Conclusion & Future

work

carg.site.uottawa.ca

CARG 2010

Objectives

• Non-invasive bidirectional human-computer interface

• Low-cost (< $20)• Faster training time

carg.site.uottawa.ca

CARG 2010

Motivation

• HCI devices used by hospitals to alleviate suffering of patients that have lost vision, balance, or mobility.

• HCI devices very expensive• Neuroplasticity

CARG 2010

carg.site.uottawa.ca

mclasen.com

Neuroplasticity

Property of the brain to reorganize itself• Phantom limbs• Treatment of brain damage• Treatment of learning difficulties

CARG 2010

carg.site.uottawa.ca

brainline.org

HCI State-of-art

• Brainport [Danilov05]

• BCI 2000 [Schalk08]

• BCCI[Walter09]

• Oral Tactile Interface[Tang06]

periodistadigital.com

gtec.at

met.usc.edu

CARG 2010

carg.site.uottawa.ca

Designed Prototype (BHCI):

Approach taken

carg.site.uottawa.ca

CARG 2010

Human FPGA TDU

Pushbuttons

VGA Serial Data

Balance Data*

*Wicab has applied for provisional patents for the use of balance data for TDUs.

Tongue Display Unit (TDU)

carg.site.uottawa.ca

CARG 2010

• A TDU actuates signals onto the tongue using an electrode array

• Data is received by the brain and interpreted

• Signals such as balance [Danilov05] and tactile information [Tang06] are observed

Advantages

• Low cost• Simple architecture• Flexible software

CARG 2010

carg.site.uottawa.ca

Safety Issues and Considerations

carg.site.uottawa.ca

Murphy and His Law•We naturally assume that any system plugged into the wall should not be connected to a person.No Human Testing, Not Yet•For now we are doing testing with a digital oscilloscope and a multimeter.Wireless is the Future•[Danilov05] and [Tang06], started with wired designs and left wireless as future work.

CARG 2010

Computer-Human Interface

carg.site.uottawa.ca

Sensory Perception•What humans feel

CARG 2010

Current (mA) 1 second Feeling *

1 Tingling

5 Maximum harmless current

10-20 Muscular contraction (pain, unsafe)

100-300 Ventricular Fibrillation (can kill)

6000 Defibrillation (respiratory paralysis and burns if sustained)

*http://www.highvoltageconnection.com/articles/ElectricShockQuestions.htm

Computer-Human Interface

carg.site.uottawa.ca

Actuating Signals Onto the Tongue•12th cranial nerve [Lin09].•Resistance of tongue [Faes99].•Approaches to signal actuation:

• Capacitive conductor (grayscale)• Time multiplexing (row, column) • Roof of the mouth [Tang06]• Surface of tongue (BHCI, Brainport)

CARG 2010

Results

carg.site.uottawa.ca

Low Cost and Proper Operation

CARG 2010

The design does not go near the current limit and was designed with very low cost components. *

http://www.youtube.com/user/uottawaBHCI#p/a/u/0/Sm0DINKrUHg

Conclusion & Future workCARG 2010

carg.site.uottawa.ca

• Human testing may follow, eventually.• Open collector ICs are required to fix fluctuating

output voltage.• An upgrade to wireless is needed to approval for

human testing.• Cleaning protocol• Plastic sealant

A low cost HCI was designed, implemented, and tested in the lab.

References• [Danilov05] Y. Danilov and M. Tyler, “Brainport: an alternative input to the brain.”Journal of integrative neuroscience, vol. 4, no. 4, p. 537, 2005.• [Tang06] H. Tang and D. Beebe, “An oral tactile interface for blind navigation,”Neural Systems and Rehabilitation Engineering, IEEE Transactions on, vol. 14, no. 1, pp.

116 –123, march 2006.• [Lin09] H. Lin, P. Barkhaus, “Cranial Nerve XII: The Hypoglossal Nerve”, Seminars in

Neurology, vol. 29, no. 1, p.45-52.• [Faes99] T. J. C. Faes, H. A. van der Meij, J. C. de Munck, and R. M.Heethaar, “The electric resistivity of human tissues (100 hz-10 mhz): a meta-analysis

of review studies,” Physiological Measurement, vol. 20, no. 4, p. R1, 1999.• [Borisenko10] A.Borisenko, L. Monczak, I. S. Samra, O. Draghici, D. Shapiro, V.

Groza, “A Low Cost Bidirectional Human-Computer Interface,” Medical Measurements and Applications (MeMeA), Apr. 2010.