Post on 13-Mar-2015
transcript
High Voltage NEMA MotorsTechnical catalogue
2 ABB /BU Machines/NEMA catalogue EN 02-2009
ABB /BU Machines/NEMA catalogue EN 02-2009 3
High Voltage NEMA Motors From 125 to 4500 HP
Contents Page
Standard motors, HXR & AMA 5
Standard motors, M3BM/GM 35
Engineered motors, HXR & AMA 61
1
2
3
ABB reserves the right to change the design, technical specification and dimensions without prior notice.
1
2
3
4 ABB /BU Machines/NEMA catalogue EN 02-2009
General InformationThis catalogue presents ABB's high voltage induction motors' offering up to 4500 HP. The motors in part 1 and 2 are standard motors with limited modification options. The motors in part 3 are engineered according to the customers' expectations. This catalogue includes the standard technical data and drawings.
1
Standard NEMA motors Modular induction and cast iron motors
Squirrel cage three phase high voltage motors, Up to 4000 HP
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 5
6 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
Contents PageGeneral information 7
Enclosure and cooling 9
Bearings 11
Frame sizes 11
Notes 12
Technical data 13 Technical data, HV modular induction motors, standard 14 Technical data, HV cast iron motors, standard 19 Dimension drawings, HV modular induction motors, standard, WPII 23 Dimension drawings, HV modular induction motors, standard, WPII, vertical 25 Dimension drawings, HV cast iron motors, engineered, TEFC, F1 26 Dimension drawings, HV cast iron motors, engineered, TEFC, F2 28 Dimension drawings, HV cast iron motors, engineered, TEFC, F1, flange mouting 30 Dimension drawings, HV cast iron motors, engineered, TEFC, F2, flange mouting 31 Dimension drawings, HV cast iron motors, engineered, TEFC, vertical 32 NEMA type II terminal box (normal size) 33 NEMA type II terminal box (over size) 34
ABB reserves the right to change the design, technical specification and dimensions without prior notice.
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 7
1
General information
Output ranges of ABB NEMA motors (Temperature rise class B, insulation class F). Other voltages on request.
Mounting arrangement
Standard mounting arrangements for AMA motors. Other mountings on request.
Code I: IM B3Code II: IM 1001
Horizontal foot mounted
Code I: IM V1Code II: IM 4011
Vertical flange mounted (free shaft end facing downwards)
This catalogue contains information on ABB’s standard construction squirrel-cage induction motors operating at 60 Hz and with synchronous speed from 720 to 3600 rpm. The output range is from 150 HP to 4500 HP.
This section describes two different motor types, the standard AMA range and the standard HXR range. Both motor types can be operated as an induction generator and motors can be mounted horizontally or vertically. Either motor can be used for both standard and special applications.
The standard AMA range features a welded steel frame and is available as standard with cooling method WPII. Other cooling methods by request, please contact your local sales office. The standard shaft heights are between 400 and 500 mm (NEMA frames 68xx to 80xx).
The standard HXR range features a rugged cast iron frame and is totally enclosed fan cooled motor of TEFC. HXR motors have standard shaft heights between 355 and 560 mm (NEMA frames 58xx to 88xx).
The table below shows the available output power, voltage range and pole numbers.
Output (HP) at 60 Hz Output (HP) at 60 Hz HXR AMA
Poles 2.3 kV 4 kV 2.3 kV 4 kV 6.6 kV
2 150 - 1500 150 - 1500 1000 - 3500 1000 - 3500 1000 - 35004 150 - 3000 150 - 3000 1000 - 4000 1000 - 4000 1000 - 40006 150 - 3000 150 - 3000 800 - 3500 800 - 3000 800 - 30008 200 - 2500 200 - 2250 500 - 2500 500 - 2250 500 - 225010 200 - 2000 250 - 2000 400 - 1750 400 - 1750 400 - 175012 200 - 1750 200 - 1500 250 - 1250 250 - 1250 –
8 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
Standard mounting arrangements for HXR motors
Code I: IM B3Code II: IM 1001
Standard floor mounting, feet facing downwards (Horizontal foot mounted)
Code I: IM V1Code II: IM 3011
Flange and free shaft end facing downwards (Vertical solid shaft, flange mounted)
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 9
1
Enclosure and coolingStandard combinations used for AMA-motors are:
WPII (IP24W)
This weather-protected motor has a shaft-mounted cooling fan located inside the housing. The designof the motor reduces the ingress of rain, snow and airborne particles into the electrical parts. On the air intake path this is achieved by ensuring that the average velocity does not exceed 3 m/s, allowing any heavier particles to settle. The design of air intake path includes three acute changes in excess of 90 degrees to further reduce the flow rate to optimum level. The motor is protected against splashing water from any direction.
TEAAC (IP55)
In this design the fully enclosed motor has an air-to-air heat exchanger mounted on the motor. Shaft mounted fans are fitted both inside and outside of the casing to supply the inside and outside cooling circuits respectively. The motor is protected against dust and splashing water from any direction.
TEWAC (IP55)
This fully enclosed motor is fitted with an air-to-water heat exchanger. A shaft mounted fan is fitted inside the casing to supply the internal cooling circuit. Motor is protected against dust and splashing water from any direction.
The terminal boxes have a protection of at least IP55.
10 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
Standard designs for AMA-motors are:
- Weather-protected Motor TYPE II (WPII) acc. to NEMA MG1 - 1.25.8.2. The corresponding AMA design acc. to IEC 34 is IC01 IPW24.- Totally-enclosed water-air-cooled Motor (TEWAC) acc. to NEMA MG1 - 1.26.8. The corresponding AMA design acc. to IEC 34 is IC81W IP55.- Totally-enclosed air-to-air-cooled Motor (TEAAC) acc. to NEMA MG1 - 1.26.9. The corresponding AMA design acc. to IEC 34 is IC611 IP55.
Available as option:
- Washable reusable filters for the weather-protected motor IC01 IP23/IPW24. The filter material is normally stainless steel.- Motor with long connecting cables without main terminal box.
TEFC (IP55) HXR motor
The HXR motor has an external shaft mounted fan that use the surrounding air for cooling. The motor is protected
against dust and water jets. The principle of this motor is shown in below:
Sectional drawing of TEFC / IP55 motor.
Protection definition IP55
Dust-protected motor: In dust-protected motor, some dust can ingress the motor but it does not enter in sufficient quantity to interfere with the motor's operation.
The motor protected against water jets: Water projected by a nozzle against the motor from any direction shall have no harmful effect.
Method of Cooling (TEFC)
Frame surface cooled: The primary coolant is circulated in a closed circuit in the motor and gives its heat through the external surface of the motor (in addition to the heat transfer via the stator core and other heat conducting parts) to the final coolant which is the surrounding medium. The surface may be plain or ribbed, with or without an outer shell to improve the heat transfer.
Self circulation: The coolant is moved dependent on the rotational speed of the main motor either by action of the rotor alone or by means of a component designed for this purpose and mounted directly on the rotor of the main motor, or by a fan or pump unit mechanically driven by the rotor or the main motor.
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 11
1
Type designation
Frame sizesIEC Equivalent to NEMA series*
400 68xx450 72xx500 80xx
* The NEMA frames are for reference only. Actual frame heights are presented in the technical section.
The type designation of the AMA motor follows the coding principle shown below.
Example: AMA 450L4A BATH1 AM Stands for Alternating Current Machines2 A Indicates the type of motor, A - E = SCIM, K - P = WRIM3 450 Frame size in mm, 400, 450 or 5004 L Frame length, S = small, M = medium or L = long5 4 Number of poles6 A Stands for the IC/IP combination L = IC81W / IP54 (55) [TEWAC] W = IC01 / IPW24 [WP II] A = IC611 / IP54 (55) [TEAAC]7 B Mounting arrangement, B = IM1001 (Horizontal), V = IM4011 (Vertical)8 A Bearing type, A = antifriction, S = sleeve9 T Indication of special construction T = separate ventilation X = electrically special N = Non-sparking design F = frequency converter drive Y = mechanically special10 H Location of manufacture H = Helsinki S = Shanghai (China)
BearingsFurther information about bearings and lubrication intervals, please see Section 3 "Engineered motors".
The type designation of the HXR motor follows the coding principle shown below.
Example: HXR 355LA41. HXR Stands for the HXR motor family, three digits.2. 355 Shaft height in mm, three digits.3. L Frame length, one digit.4. A Core length, one digit.5. 4 Number of poles.
12 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
NotesAll ratings in this catalogue are designed for the following:
- Horizontal mounting- 3 phase- Class F insulation- Service factor of 1.0- Maximum temperature rise of 80 degrees C by -resistance at 1.0 service factor- Maximum 104 degrees F (40 degrees C) ambient- Altitude of 3300 feet or less
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 13
1
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, standardTechnical data for open weather protected three phase motorsWPII – Insulation class F, temperature rise class B, S.F. 1.0
2300 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
Data presented in rating lists are typical values. Guaranteed values on request. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
2300 V 60 Hz250 600 AMA 400L12W 289 593 91.9 91.6 0.71 0.65 72 40 394 D 2211 71 181 6041 77
300 600 AMA 400L12W 290 593 92.1 91.7 0.69 0.62 89 52 407 E 2660 76 190 6261 77
350 600 AMA 400L12W 291 593 92.3 92.0 0.70 0.64 101 57 399 E 3101 74 182 6482 77
400 720 AMA 400L10W 278 711 93.3 93.4 0.76 0.71 106 52 419 D 2952 65 179 6063 77
400 600 AMA 400L12W 292 592 92.5 92.4 0.73 0.67 111 57 383 D 3544 69 171 6878 77
450 720 AMA 400L10W 279 711 93.4 93.6 0.76 0.72 118 55 409 D 3330 63 173 6261 77
450 600 AMA 400L12W 293 593 92.7 92.5 0.71 0.65 128 69 397 D 3993 74 178 7099 77
500 900 AMA 400L8W 266 889 94.1 94.4 0.83 0.81 119 43 463 D 2955 74 184 6063 77
500 720 AMA 400L10W 280 711 93.5 93.8 0.77 0.72 131 61 414 D 3696 65 177 6482 77
500 600 AMA 400L12W 294 593 92.8 92.5 0.71 0.64 143 79 412 E 4429 77 185 7518 77
600 900 AMA 400L8W 267 889 94.3 94.6 0.84 0.81 142 49 452 D 3551 73 178 6283 77
600 720 AMA 400L10W 281 711 93.9 94.0 0.77 0.72 156 73 438 E 4435 69 180 7099 77
600 600 AMA 450L12W 295 593 94.0 94.2 0.76 0.72 156 73 422 D 5319 70 180 8686 78
700 900 AMA 400L8W 268 889 94.5 94.8 0.83 0.80 166 60 471 D 4135 78 184 6482 77
700 720 AMA 400L10W 282 711 94.0 94.2 0.77 0.72 181 83 438 E 5168 70 177 7518 77
700 600 AMA 450L12W 296 594 94.1 94.1 0.75 0.69 186 94 441 E 6191 73 191 9171 78
800 1200 AMA 400L6W 256 1187 94.7 95.0 0.83 0.80 190 71 502 E 3542 73 201 6085 79
800 900 AMA 400L8W 269 890 94.5 94.8 0.83 0.80 190 69 477 D 4727 78 185 6856 77
800 720 AMA 450L10W 283 712 94.4 94.7 0.82 0.79 193 73 450 D 5908 73 181 8400 78
800 600 AMA 450L12W 297 594 94.2 94.3 0.76 0.71 209 101 441 E 7083 74 187 9700 78
900 1200 AMA 400L6W 257 1188 94.9 95.1 0.82 0.79 215 84 513 E 3979 76 204 6305 79
900 900 AMA 400L8W 270 889 94.6 94.9 0.83 0.81 213 77 479 E 5313 80 184 7055 77
900 720 AMA 450L10W 284 712 94.5 94.8 0.82 0.79 217 83 455 D 6640 75 181 8664 78
900 600 AMA 500L12W 298 594 94.6 94.7 0.77 0.72 230 107 452 E 7955 69 186 11133 79
1000 3600 AMA 400L2W 237 3579 95.5 95.6 0.89 0.87 220 60 592 F 1468 60 249 6437 85
1000 1800 AMA 400L4W 246 1785 95.1 95.3 0.88 0.86 223 65 530 E 2943 65 213 6283 80
1000 1200 AMA 400L6W 258 1188 95.1 95.3 0.83 0.80 237 91 520 E 4423 78 204 6526 79
1000 900 AMA 400L8W 271 889 94.7 95.1 0.84 0.82 234 79 475 D 5909 80 181 7474 77
1000 720 AMA 450L10W 285 712 94.6 95.0 0.83 0.80 239 86 448 D 7383 73 178 9193 78
1000 600 AMA 500L12W 299 594 94.7 94.9 0.78 0.74 252 111 446 D 8845 68 183 11795 79
14 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
Data presented in rating lists are typical values. Guaranteed values on request. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
2300 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
HV Modular induction motors, standardTechnical data for open weather protected three phase motorsWPII – Insulation class F, temperature rise class B, S.F. 1.0
2300 V 60 Hz1250 3600 AMA 400L2W 238 3579 95.7 95.8 0.88 0.86 277 80 597 F 1834 62 249 6614 85
1250 1800 AMA 400L4W 247 1785 95.3 95.6 0.88 0.86 280 80 521 E 3678 67 206 6504 80
1250 1200 AMA 400L6W 259 1189 95.3 95.5 0.82 0.79 298 117 535 F 5527 80 204 7099 79
1250 900 AMA 450L8W 272 892 95.3 95.6 0.84 0.81 292 105 509 E 7361 72 193 8708 78
1250 720 AMA 500L10W 286 714 95.3 95.5 0.81 0.77 301 125 515 E 9189 68 203 11486 79
1250 600 AMA 500L12W 300 595 95.0 95.0 0.78 0.73 316 146 476 E 11042 74 195 13118 79
1500 3600 AMA 400L2W 239 3579 95.9 96.1 0.89 0.87 328 87 587 F 2202 59 246 6900 85
1500 1800 AMA 400L4W 248 1784 95.3 95.7 0.87 0.85 338 99 515 E 4417 67 204 6680 80
1500 1200 AMA 450L6W 260 1191 95.6 95.8 0.86 0.83 341 110 543 E 6618 65 205 8774 81
1500 900 AMA 450L8W 273 893 95.6 95.8 0.83 0.79 355 137 522 E 8830 72 195 9502 78
1500 720 AMA 500L10W 287 714 95.4 95.6 0.82 0.78 358 143 504 E 11036 67 196 12147 79
1750 3600 AMA 400L2W 240 3579 96.0 96.3 0.89 0.88 380 94 594 F 2568 65 243 7385 85
1750 1800 AMA 400L4W 249 1785 95.6 96.0 0.89 0.88 385 98 521 E 5149 65 203 7121 80
1750 1200 AMA 450L6W 261 1191 95.7 96.0 0.86 0.83 399 128 535 E 7726 65 202 9061 81
1750 900 AMA 500L8W 274 891 95.6 96.0 0.86 0.84 397 118 492 D 10311 66 192 11177 79
1750 720 AMA 500L10W 288 714 95.6 95.7 0.82 0.79 415 161 509 E 12869 68 196 13140 79
2000 3600 AMA 450L2W 241 3579 96.0 96.0 0.88 0.86 443 124 546 E 2936 51 235 8752 86
2000 1800 AMA 450L4W 250 1784 95.4 95.7 0.87 0.86 448 117 489 D 5889 65 189 8466 81
2000 1200 AMA 450L6W 262 1190 95.8 96.1 0.87 0.85 449 132 544 E 8828 69 204 9590 81
2000 900 AMA 500L8W 275 892 95.6 96.1 0.87 0.85 450 127 499 D 11784 67 193 12170 79
2250 3600 AMA 450L2W 242 3578 96.1 96.3 0.89 0.88 491 119 521 E 3303 49 221 9127 86
2250 1800 AMA 450L4W 251 1785 95.6 95.9 0.87 0.86 504 132 500 D 6626 68 192 8752 81
2250 1200 AMA 500L6W 263 1191 95.8 96.1 0.87 0.85 505 148 538 E 9926 70 205 10913 81
2250 900 AMA 500L8W 276 892 95.8 96.2 0.86 0.85 508 150 508 E 13247 67 191 12831 79
2500 3600 AMA 450L2W 243 3579 96.6 96.7 0.90 0.89 539 124 547 E 3670 54 229 9811 86
2500 1800 AMA 450L4W 252 1786 96.1 96.3 0.89 0.88 547 129 522 E 7354 66 195 9326 81
2500 1200 AMA 500L6W 264 1192 96.3 96.6 0.89 0.87 547 143 549 E 11020 67 206 11640 81
2500 900 AMA 500L8W 511 892 96.0 96.4 0.87 0.86 558 152 504 D 14729 69 193 13404 79
3000 3600 AMA 500L2W 244 3580 96.5 96.5 0.90 0.89 643 147 556 E 4403 53 236 12081 87
3000 1800 AMA 500L4W 253 1790 96.3 96.4 0.87 0.85 669 195 555 E 8804 65 207 11244 83
3000 1200 AMA 500L6W 265 1192 96.4 96.7 0.89 0.89 650 152 541 E 13226 67 200 12632 81
3500 3600 AMA 500L2W 245 3579 96.6 96.7 0.91 0.90 744 153 548 E 5138 54 228 12853 87
3500 1800 AMA 500L4W 254 1790 96.5 96.6 0.88 0.87 770 204 555 E 10271 66 203 11971 83
3500 1200 AMA 500L6W 510 1193 96.6 96.8 0.89 0.88 762 193 562 E 15421 69 204 13558 81
4000 1800 AMA 500L4W 255 1790 96.6 96.8 0.88 0.87 875 221 559 E 11738 68 203 12632 83
4500 1800 AMA 500L4W 509 1790 96.7 96.9 0.89 0.88 974 228 560 E 13206 70 200 13316 83
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 15
1
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, standardTechnical data for open weather protected three phase motorsWPII – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
Data presented in rating lists are typical values. Guaranteed values on request. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
4000 V 60 Hz250 600 AMA 400L12W 289 593 91.9 91.6 0.71 0.65 41 22 394 D 2211 71 181 6041 77
300 600 AMA 400L12W 290 593 92.1 91.7 0.69 0.62 51 29 407 E 2660 76 190 6261 77
350 600 AMA 400L12W 291 593 92.3 92.0 0.70 0.64 58 32 399 E 3101 74 182 6482 77
400 720 AMA 400L10W 278 711 93.3 93.4 0.76 0.71 61 29 419 D 2952 65 179 6063 77
400 600 AMA 400L12W 292 592 92.5 92.4 0.73 0.67 64 32 383 D 3544 69 171 6878 77
450 720 AMA 400L10W 279 711 93.4 93.6 0.76 0.72 68 31 409 D 3330 63 173 6261 77
450 600 AMA 400L12W 293 593 92.7 92.5 0.71 0.65 73 39 397 D 3993 74 178 7099 77
500 900 AMA 400L8W 266 889 94.1 94.4 0.83 0.81 68 24 463 D 2955 74 184 6063 77
500 720 AMA 400L10W 280 711 93.5 93.8 0.77 0.72 75 34 414 D 3696 65 177 6482 77
500 600 AMA 400L12W 294 593 92.8 92.5 0.71 0.64 82 45 412 E 4429 77 185 7518 77
600 900 AMA 400L8W 267 889 94.3 94.6 0.84 0.81 82 28 452 D 3551 73 178 6283 77
600 720 AMA 400L10W 281 711 93.9 94.0 0.77 0.72 90 41 438 E 4435 69 180 7099 77
600 600 AMA 450L12W 295 593 94.0 94.2 0.76 0.72 90 42 422 D 5319 70 180 8686 78
700 900 AMA 400L8W 268 889 94.5 94.8 0.83 0.80 96 34 471 D 4135 78 184 6482 77
700 720 AMA 400L10W 282 711 94.0 94.2 0.77 0.72 104 47 438 E 5168 70 177 7518 77
700 600 AMA 450L12W 296 594 94.1 94.1 0.75 0.69 107 54 441 E 6191 73 191 9171 78
800 1200 AMA 400L6W 256 1187 94.7 95.0 0.83 0.80 109 41 502 E 3542 73 201 6085 79
800 900 AMA 400L8W 269 890 94.5 94.8 0.83 0.80 109 39 477 D 4727 78 185 6856 77
800 720 AMA 450L10W 283 712 94.4 94.7 0.82 0.79 111 42 450 D 5908 73 181 8400 78
800 600 AMA 450L12W 297 594 94.2 94.3 0.76 0.71 120 58 441 E 7083 74 187 9700 78
900 1200 AMA 400L6W 257 1188 94.9 95.1 0.82 0.79 124 48 513 E 3979 76 204 6305 79
900 900 AMA 400L8W 270 889 94.6 94.9 0.83 0.81 123 44 479 E 5313 80 184 7055 77
900 720 AMA 450L10W 284 712 94.5 94.8 0.82 0.79 125 47 455 D 6640 75 181 8664 78
900 600 AMA 500L12W 298 594 94.6 94.7 0.77 0.72 132 61 452 E 7955 69 186 11133 79
1000 3600 AMA 400L2W 237 3579 95.5 95.6 0.89 0.87 127 34 592 F 1468 60 249 6437 85
1000 1800 AMA 400L4W 246 1785 95.1 95.3 0.88 0.86 129 37 530 E 2943 65 213 6283 80
1000 1200 AMA 400L6W 258 1188 95.1 95.3 0.83 0.80 136 51 520 E 4423 78 204 6526 79
1000 900 AMA 400L8W 271 889 94.7 95.1 0.84 0.82 135 45 475 D 5909 80 181 7474 77
1000 720 AMA 450L10W 285 712 94.6 95.0 0.83 0.80 137 49 448 D 7383 73 178 9193 78
1000 600 AMA 500L12W 299 594 94.7 94.9 0.78 0.74 145 63 446 D 8845 68 183 11795 79
16 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
Data presented in rating lists are typical values. Guaranteed values on request. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
HV Modular induction motors, standardTechnical data for open weather protected three phase motorsWPII – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz1250 3600 AMA 400L2W 238 3579 95.7 95.8 0.88 0.86 160 46 597 F 1834 62 249 6614 85
1250 1800 AMA 400L4W 247 1785 95.3 95.6 0.88 0.86 161 45 521 E 3678 67 206 6504 80
1250 1200 AMA 400L6W 259 1189 95.3 95.5 0.82 0.79 172 67 535 F 5527 80 204 7099 79
1250 900 AMA 450L8W 272 892 95.3 95.6 0.84 0.81 168 60 509 E 7361 72 193 8708 78
1250 720 AMA 500L10W 286 714 95.3 95.5 0.81 0.77 173 71 515 E 9189 68 203 11486 79
1250 600 AMA 500L12W 300 595 95.0 95.0 0.78 0.73 182 84 476 E 11042 74 195 13118 79
1500 3600 AMA 400L2W 239 3579 95.9 96.1 0.89 0.87 189 50 587 F 2202 59 246 6900 85
1500 1800 AMA 400L4W 248 1784 95.3 95.7 0.87 0.85 195 57 515 E 4417 67 204 6680 80
1500 1200 AMA 450L6W 260 1191 95.6 95.8 0.86 0.83 197 63 543 E 6618 65 205 8774 81
1500 900 AMA 450L8W 273 893 95.6 95.8 0.83 0.79 205 79 522 E 8830 72 195 9502 78
1500 720 AMA 500L10W 287 714 95.4 95.6 0.82 0.78 207 82 504 E 11036 67 196 12147 79
1750 3600 AMA 400L2W 240 3579 96.0 96.3 0.89 0.88 219 54 594 F 2568 65 243 7385 85
1750 1800 AMA 400L4W 249 1785 95.6 96.0 0.89 0.88 222 56 521 E 5149 65 203 7121 80
1750 1200 AMA 450L6W 261 1191 95.7 96.0 0.86 0.83 230 73 535 E 7726 65 202 9061 81
1750 900 AMA 500L8W 274 891 95.6 96.0 0.86 0.84 229 68 492 D 10311 66 192 11177 79
1750 720 AMA 500L10W 288 714 95.6 95.7 0.82 0.79 239 92 509 E 12869 68 196 13140 79
2000 3600 AMA 450L2W 241 3579 96.0 96.0 0.88 0.86 255 71 546 E 2936 51 235 8752 86
2000 1800 AMA 450L4W 250 1784 95.4 95.7 0.87 0.86 259 67 489 D 5889 65 189 8466 81
2000 1200 AMA 450L6W 262 1190 95.8 96.1 0.87 0.85 259 76 544 E 8828 69 204 9590 81
2000 900 AMA 500L8W 275 892 95.6 96.1 0.87 0.85 260 73 499 D 11784 67 193 12170 79
2250 3600 AMA 450L2W 242 3578 96.1 96.3 0.89 0.88 283 68 521 E 3303 49 221 9127 86
2250 1800 AMA 450L4W 251 1785 95.6 95.9 0.87 0.86 291 75 500 D 6626 68 192 8752 81
2250 1200 AMA 500L6W 263 1191 95.8 96.1 0.87 0.85 291 85 538 E 9926 70 205 10913 81
2250 900 AMA 500L8W 276 892 95.8 96.2 0.86 0.85 293 86 508 E 13247 67 191 12831 79
2500 3600 AMA 450L2W 243 3579 96.6 96.7 0.90 0.89 311 71 547 E 3670 54 229 9811 86
2500 1800 AMA 450L4W 252 1786 96.1 96.3 0.89 0.88 315 74 522 E 7354 66 195 9326 81
2500 1200 AMA 500L6W 264 1192 96.3 96.6 0.89 0.87 316 82 549 E 11020 67 206 11640 81
3000 3600 AMA 500L2W 244 3580 96.5 96.5 0.90 0.89 371 84 556 E 4403 53 236 12081 87
3000 1800 AMA 500L4W 253 1790 96.3 96.4 0.87 0.85 386 112 555 E 8804 65 207 11244 83
3000 1200 AMA 500L6W 265 1192 96.4 96.7 0.89 0.89 375 87 541 E 13226 67 200 12632 81
3500 3600 AMA 500L2W 245 3579 96.6 96.7 0.91 0.90 430 88 548 E 5138 54 228 12853 87
3500 1800 AMA 500L4W 254 1790 96.5 96.6 0.88 0.87 445 117 555 E 10271 66 203 11971 83
4000 1800 AMA 500L4W 255 1790 96.6 96.8 0.88 0.87 505 127 559 E 11738 68 203 12632 83
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 17
1
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, standardTechnical data for open weather protected three phase motorsWPII – Insulation class F, temperature rise class B, S.F. 1.0
6600 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
Data presented in rating lists are typical values. Guaranteed values on request. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
6600 V 60 Hz400 720 AMA 400L10W 278 711 93.0 93.2 0.76 0.71 37 17 410 D 2953 63 175 5975 77
450 720 AMA 400L10W 279 711 93.2 93.4 0.76 0.72 41 19 413 D 3329 64 174 6173 77
500 900 AMA 400L8W 266 889 93.8 94.2 0.84 0.81 41 14 451 D 2956 72 179 5952 77
500 720 AMA 400L10W 280 711 93.4 93.5 0.75 0.70 46 22 434 E 3693 69 178 6393 77
600 900 AMA 400L8W 267 889 94.0 94.4 0.84 0.81 50 18 463 D 3550 76 182 6173 77
600 720 AMA 400L10W 281 712 93.6 93.7 0.76 0.71 55 26 447 E 4433 71 182 6989 77
700 900 AMA 400L8W 268 888 94.0 94.6 0.84 0.82 58 19 434 D 4140 71 169 6371 77
700 720 AMA 400L10W 282 711 93.7 94.0 0.78 0.74 62 26 405 D 5174 62 167 7385 77
800 1200 AMA 400L6W 256 1189 94.5 94.7 0.80 0.75 69 31 548 F 3537 84 225 5997 79
800 900 AMA 400L8W 269 889 94.4 94.8 0.84 0.81 66 23 466 D 4728 76 181 6790 77
800 720 AMA 450L10W 283 712 94.2 94.6 0.82 0.79 68 26 456 D 5907 74 183 8311 78
900 1200 AMA 400L6W 257 1188 94.7 94.9 0.82 0.78 76 31 524 F 3978 78 209 6195 79
900 900 AMA 400L8W 270 890 94.5 94.9 0.83 0.80 75 27 486 E 5312 81 186 6989 77
900 720 AMA 450L10W 284 712 94.2 94.5 0.81 0.77 77 31 480 E 6635 80 191 8510 78
1000 3600 AMA 400L2W 237 3577 95.3 95.5 0.90 0.88 76 18 548 E 1469 55 228 6305 85
1000 1800 AMA 400L4W 246 1783 94.8 95.2 0.89 0.88 77 18 467 D 2947 56 179 6195 80
1000 1200 AMA 400L6W 258 1187 94.8 95.2 0.85 0.82 81 27 483 D 4427 70 187 6415 79
1000 900 AMA 400L8W 271 890 94.5 94.8 0.84 0.81 82 30 505 E 5904 87 191 7341 77
1000 720 AMA 450L10W 285 711 94.2 94.7 0.83 0.81 83 29 436 D 7386 71 173 9039 78
1250 3600 AMA 400L2W 238 3579 95.7 95.8 0.88 0.86 96 27 586 F 1834 61 244 6570 85
1250 1800 AMA 400L4W 247 1783 95.0 95.5 0.89 0.88 97 24 483 D 3681 61 191 6393 80
1250 1200 AMA 400L6W 259 1189 95.2 95.4 0.82 0.78 105 42 541 F 5527 81 208 7033 79
1250 900 AMA 450L8W 272 892 95.1 95.4 0.83 0.79 104 41 537 F 7357 77 205 8576 78
1250 720 AMA 500L10W 286 715 95.2 95.3 0.81 0.76 106 45 527 F 9187 70 207 11332 79
1500 3600 AMA 400L2W 239 3580 95.9 96.1 0.89 0.87 115 31 595 F 2202 60 249 6834 85
1500 1800 AMA 400L4W 248 1784 95.3 95.7 0.87 0.86 118 33 505 E 4417 65 199 6636 80
1500 1200 AMA 450L6W 260 1191 95.6 95.8 0.86 0.83 120 39 552 F 6617 66 209 8730 81
1500 900 AMA 450L8W 273 893 95.4 95.6 0.82 0.78 125 50 535 F 8828 74 202 9370 78
1500 720 AMA 500L10W 287 714 95.2 95.5 0.83 0.80 124 44 466 D 11044 60 181 11971 79
18 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, standardTechnical data for open weather protected three phase motorsWPII – Insulation class F, temperature rise class B, S.F. 1.0
6600 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
Data presented in rating lists are typical values. Guaranteed values on request. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
6600 V 60 Hz1750 3600 AMA 400L2W 240 3580 96.0 96.2 0.89 0.87 134 37 628 F 2568 69 258 7319 85
1750 1800 AMA 400L4W 249 1785 95.6 96.0 0.88 0.87 135 35 528 E 5148 66 206 7055 80
1750 1200 AMA 450L6W 261 1191 95.7 95.9 0.84 0.81 141 49 567 F 7722 71 217 9017 81
1750 900 AMA 500L8W 274 891 95.3 95.8 0.86 0.85 139 40 480 D 10313 64 186 11023 79
1750 720 AMA 500L10W 288 714 95.4 95.6 0.83 0.79 144 54 497 E 12871 65 191 12963 79
2000 3600 AMA 450L2W 241 3581 96.0 96.0 0.87 0.84 156 48 576 F 2935 54 249 8686 86
2000 1800 AMA 450L4W 250 1785 95.4 95.7 0.87 0.86 157 42 496 D 5888 66 191 8400 81
2000 1200 AMA 450L6W 262 1192 95.9 96.1 0.85 0.82 160 56 608 F 8819 80 239 9546 81
2000 900 AMA 500L8W 275 892 95.5 95.9 0.87 0.85 158 46 513 E 11781 69 198 11993 79
2250 3600 AMA 450L2W 242 3580 96.1 96.2 0.88 0.85 174 51 579 F 3301 56 248 9061 86
2250 1800 AMA 450L4W 251 1786 95.6 95.9 0.86 0.85 178 52 528 E 6622 73 204 8708 81
2250 1200 AMA 500L6W 263 1192 95.6 95.9 0.86 0.84 178 55 551 E 9924 72 211 10759 81
2250 900 AMA 500L8W 276 891 95.5 96.0 0.87 0.86 177 46 465 D 13258 60 178 12655 79
2500 3600 AMA 450L2W 243 3579 96.5 96.6 0.90 0.88 189 45 562 E 3670 55 235 9634 86
2500 1800 AMA 450L4W 252 1788 96.2 96.3 0.87 0.85 194 56 583 F 7347 76 224 9281 81
2500 1200 AMA 500L6W 264 1191 96.1 96.4 0.89 0.88 191 44 504 D 11027 60 188 11464 81
3000 3600 AMA 500L2W 244 3578 96.3 96.5 0.90 0.90 225 46 515 D 4405 49 217 11927 87
3000 1800 AMA 500L4W 253 1790 96.1 96.4 0.88 0.87 231 58 517 E 8808 60 192 11155 83
3000 1200 AMA 500L6W 265 1192 96.2 96.6 0.89 0.89 228 51 527 E 13228 65 194 12412 81
3500 3600 AMA 500L2W 245 3579 96.6 96.7 0.91 0.90 260 52 536 E 5139 53 223 12809 87
3500 1800 AMA 500L4W 254 1790 96.5 96.6 0.88 0.87 269 68 545 E 10273 65 199 11927 83
4000 1800 AMA 500L4W 255 1791 96.6 96.8 0.88 0.87 307 79 567 E 11737 69 205 12588 83
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 19
1
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
2300 V 60 Hz
Data presented in rating lists are typical values. Guaranteed values on request. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
HV Cast iron motors, standardTechnical data for totally enclosed squirrel cage three phase motors TEFC – Insulation class F, temperature rise class B, S.F. 1.0
IEC frame size NEMA frame size
355 58xx
400 68xx
450 72xx
500 80xx
560 88xx
2300 V 60 Hz150 3600 HXR 355LA2 75 3570 91.6 90.4 0.89 0.87 34 11 223 G 221 68 291 3483 89150 1800 HXR 355LA4 184 1785 92.6 91.6 0.82 0.77 37 16 227 G 442 100 242 3505 82150 1200 HXR 355LA6 299 1189 93.0 92.3 0.77 0.72 39 19 206 F 663 95 212 3483 80200 3600 HXR 355LA2 76 3570 92.7 91.9 0.90 0.88 45 13 293 G 294 67 281 3483 89200 1800 HXR 355LA4 185 1786 93.6 92.9 0.84 0.80 48 19 302 G 587 98 238 3682 82200 1200 HXR 355LA6 300 1189 93.7 93.2 0.78 0.73 51 24 278 F 883 102 211 3704 80200 900 HXR 400LA8 409 891 94.0 93.8 0.77 0.72 52 24 255 F 1178 92 197 5027 75200 720 HXR 400LB10 498 714 93.6 93.1 0.69 0.62 58 33 270 F 1469 83 200 5445 79200 600 HXR 400LC12 584 594 93.2 93.0 0.68 0.61 59 34 236 E 1768 82 172 5732 75250 3600 HXR 355LA2 77 3570 93.3 92.7 0.89 0.87 56 17 368 G 367 69 282 3483 89250 1800 HXR 355LA4 186 1786 94.1 93.7 0.85 0.82 58 21 370 G 733 93 236 3704 82250 1200 HXR 355LA6 301 1190 94.0 93.7 0.78 0.73 63 30 344 F 1101 92 213 3682 80250 900 HXR 400LA8 410 891 94.2 94.3 0.80 0.76 62 26 305 E 1470 83 198 5137 75250 720 HXR 400LC10 499 714 93.9 93.6 0.72 0.66 69 37 314 F 1836 82 185 5732 79250 600 HXR 400LE12 585 594 93.5 93.2 0.68 0.62 73 41 295 E 2207 84 172 6261 75300 3600 HXR 355LA2 78 3569 93.9 93.5 0.91 0.89 66 17 434 G 442 72 275 3682 89300 1800 HXR 355LA4 187 1785 94.4 94.1 0.85 0.82 70 25 430 G 884 92 223 3704 82300 1200 HXR 355LB6 302 1190 94.5 94.4 0.80 0.75 75 32 409 F 1326 96 206 3858 80300 900 HXR 400LB8 411 891 94.6 94.7 0.81 0.77 74 30 364 E 1770 84 194 5423 75300 720 HXR 400LD10 500 714 94.1 93.9 0.72 0.66 83 43 377 E 2211 83 182 6019 79300 600 HXR 400LG12 586 594 93.7 93.5 0.69 0.63 87 48 351 E 2657 84 170 6834 75350 3600 HXR 355LB2 79 3570 94.3 94.1 0.91 0.89 77 20 502 G 515 71 268 3902 89350 1800 HXR 355LB4 188 1786 94.8 94.5 0.86 0.82 81 28 526 G 1029 101 230 3902 82350 1200 HXR 355LC6 303 1189 94.8 94.8 0.81 0.78 85 34 455 F 1546 95 198 4101 80350 900 HXR 400LC8 412 891 94.8 94.9 0.81 0.78 85 33 407 E 2063 82 186 5600 75350 720 HXR 400LF10 501 714 94.3 94.1 0.72 0.66 96 51 453 F 2575 87 186 6460 79350 600 HXR 450LF12 588 595 94.4 94.1 0.69 0.63 100 54 413 E 3092 75 175 8576 75400 3600 HXR 355LC2 80 3571 94.6 94.5 0.92 0.91 86 20 564 G 588 68 265 4079 89400 1800 HXR 355LC4 189 1786 95.0 94.9 0.86 0.83 92 31 593 G 1175 102 225 4034 82400 1200 HXR 355LD6 304 1189 95.0 95.0 0.81 0.78 97 38 513 F 1765 95 194 4211 80400 900 HXR 400LC8 413 891 94.8 95.0 0.81 0.78 97 37 464 E 2356 83 183 5710 75400 720 HXR 400LH10 502 714 94.3 93.9 0.72 0.66 111 59 526 F 2939 87 190 7121 80400 600 HXR 450LG12 589 594 94.5 94.3 0.70 0.64 113 60 465 E 3531 75 171 8951 75450 3600 HXR 355LD2 81 3571 94.9 94.8 0.92 0.90 97 22 618 F 663 65 258 4189 89450 1800 HXR 355LD4 190 1786 95.2 95.1 0.86 0.84 103 33 642 G 1325 99 215 4233 82450 1200 HXR 355LE6 305 1189 95.1 95.2 0.82 0.78 108 41 586 F 1990 98 191 4497 80450 900 HXR 400LE8 414 892 95.1 95.2 0.81 0.77 110 45 568 F 2653 90 199 6283 75450 720 HXR 400LK10 503 714 94.4 94.1 0.72 0.66 124 65 606 F 3313 93 195 7562 80450 600 HXR 450LH12 590 594 94.6 94.4 0.70 0.65 126 66 514 E 3981 74 168 9480 75500 3600 HXR 355LD2 82 3577 95.1 94.9 0.90 0.88 110 30 758 G 734 63 285 4277 89500 1800 HXR 355LE4 191 1786 95.3 95.3 0.87 0.84 113 35 716 G 1471 101 214 4453 82500 1200 HXR 355LF6 306 1189 95.3 95.3 0.82 0.79 120 46 660 F 2209 101 195 4718 80500 900 HXR 400LG8 415 892 95.3 95.4 0.81 0.77 121 49 640 F 2944 93 202 6702 75500 720 HXR 450LF10 504 714 95.5 95.6 0.76 0.70 130 62 640 F 3678 86 192 8554 76500 600 HXR 450LK12 591 595 94.7 94.5 0.71 0.65 139 72 568 E 4419 73 168 10207 75600 3600 HXR 400LE2 83 3579 95.3 95.1 0.92 0.91 128 28 890 G 882 69 273 6107 88600 1800 HXR 400LC4 192 1789 95.7 95.6 0.87 0.84 135 43 860 G 1763 90 220 5842 80600 1200 HXR 400LE6 307 1191 95.5 95.5 0.83 0.80 141 52 814 F 2649 87 202 6305 79600 900 HXR 400LH8 416 892 95.2 95.3 0.82 0.78 145 57 758 F 3537 93 197 7143 78600 720 HXR 450LH10 505 714 95.7 95.8 0.76 0.72 154 71 751 E 4419 85 188 9259 76600 600 HXR 500LH12 592 595 95.0 94.8 0.70 0.65 168 88 724 E 5304 76 176 12919 75
20 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
2300 V 60 Hz
Data presented in rating lists are typical values. Guaranteed values on request. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
HV Cast iron motors, standardTechnical data for totally enclosed squirrel cage three phase motors TEFC – Insulation class F, temperature rise class B, S.F. 1.0
IEC frame size NEMA frame size
355 58xx400 68xx450 72xx500 80xx560 88xx
2300 V 60 Hz700 3600 HXR 400LF2 84 3578 95.6 95.5 0.93 0.92 148 30 982 F 1028 66 259 6504 88700 1800 HXR 400LD4 193 1789 95.9 95.9 0.87 0.85 156 47 984 F 2055 91 213 6129 80700 1200 HXR 400LG6 308 1191 95.7 95.7 0.84 0.81 163 57 959 F 3087 94 202 6724 79700 900 HXR 450LG8 418 894 95.7 95.7 0.82 0.78 167 67 979 F 4112 90 219 9083 76700 720 HXR 450LK10 506 714 95.8 95.9 0.76 0.71 180 85 925 F 5146 92 198 10119 76700 600 HXR 500LK12 593 595 95.1 94.9 0.71 0.65 195 102 851 E 6179 78 179 13801 75800 3600 HXR 400LH2 85 3583 95.8 95.7 0.92 0.90 171 40 1224 G 1174 63 282 6878 88800 1800 HXR 400LF4 194 1789 96.1 96.1 0.88 0.87 177 48 1102 F 2351 95 208 6702 80800 1200 HXR 400LJ6 309 1191 95.8 95.9 0.85 0.82 184 60 1049 F 3531 91 195 7430 79800 900 HXR 450LJ8 419 894 95.9 95.8 0.81 0.77 192 81 1157 G 4701 90 225 9789 76800 720 HXR 450LM10 507 715 95.7 95.8 0.76 0.71 206 98 1072 F 5884 94 200 10825 78800 600 HXR 500LL12 594 595 95.0 94.9 0.71 0.66 222 114 947 E 7069 77 173 14242 75900 3600 HXR 450LH2 86 3585 95.7 95.4 0.91 0.89 194 52 1409 G 1318 57 290 9370 91900 1800 HXR 400LH4 195 1789 96.3 96.3 0.88 0.87 198 53 1263 F 2641 99 207 7187 80900 1200 HXR 450LE6 310 1192 96.1 96.2 0.88 0.86 200 54 1111 E 3965 83 191 8466 80900 900 HXR 450LL8 420 895 96.1 96.0 0.81 0.77 215 87 1270 G 5279 91 211 10516 76900 720 HXR 500LJ10 508 715 96.1 96.2 0.78 0.74 225 97 1095 E 6613 76 188 13360 78900 600 HXR 500LN12 595 595 95.1 94.9 0.71 0.66 249 128 1079 E 7944 78 175 15080 751000 3600 HXR 500LJ2 87 3585 95.4 95.0 0.92 0.91 213 52 1515 G 1466 56 296 13360 911000 1800 HXR 450LG4 196 1790 96.2 96.2 0.89 0.87 219 60 1422 G 2935 91 221 9215 821000 1200 HXR 450LJ6 311 1193 96.3 96.4 0.88 0.86 221 62 1347 F 4404 93 208 9722 801000 900 HXR 450LN8 421 895 96.1 96.1 0.82 0.78 238 96 1411 G 5868 91 211 11244 761000 720 HXR 500LL10 509 715 96.1 96.3 0.79 0.75 248 104 1191 E 7354 75 184 14021 781000 600 HXR 500LQ12 596 595 95.2 95.1 0.72 0.67 273 134 1137 E 8837 74 167 15719 751250 3600 HXR 500LM2 88 3586 95.8 95.6 0.92 0.91 265 61 1877 G 1831 57 279 14617 911250 1800 HXR 450LL4 197 1791 96.5 96.5 0.89 0.87 272 73 1840 G 3665 98 224 10648 821250 1200 HXR 500LG6 312 1194 96.3 96.4 0.86 0.84 281 90 1721 F 5498 82 218 12588 821250 900 HXR 500LM8 422 895 96.2 96.2 0.83 0.79 293 114 1791 G 7336 86 222 14617 771250 720 HXR 500LP10 510 715 96.1 96.2 0.79 0.75 309 127 1490 E 9187 77 183 15543 801500 3600 HXR 500LQ2 89 3587 96.1 95.9 0.91 0.89 321 82 2335 G 2197 54 279 15829 911500 1800 HXR 500LJ4 198 1792 96.5 96.6 0.90 0.88 324 86 2191 G 4398 83 241 13580 821500 1200 HXR 500LK6 313 1194 96.6 96.7 0.87 0.85 332 102 2134 G 6599 83 225 13580 821500 900 HXR 500LS8 423 896 96.4 96.4 0.83 0.80 349 129 2060 F 8799 85 210 17042 771500 720 HXR 500LS10 511 715 96.1 96.2 0.79 0.74 371 159 1887 F 11018 75 189 17086 801750 1800 HXR 500LM4 199 1792 96.7 96.8 0.90 0.89 375 90 2399 F 5134 80 225 14881 821750 1200 HXR 500LM6 314 1195 96.7 96.8 0.87 0.85 388 122 2550 G 7699 84 229 14661 822000 1800 HXR 500LP4 200 1792 96.8 96.9 0.90 0.89 429 105 2853 G 5864 84 229 15675 822000 1200 HXR 500LQ6 315 1194 96.8 97.0 0.88 0.86 439 124 2752 F 8799 83 216 15984 822250 1200 HXR 500LS6 316 1196 96.9 97.0 0.86 0.83 506 171 3487 G 9881 88 226 17350 82
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 21
1
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
4000 V 60 Hz150 3600 HXR 355LA2 8662 3559 91.9 91.1 0.90 0.89 19 5 108 E 222 58 256 3527 89150 1800 HXR 355LA4 8670 1787 93.0 92.2 0.82 0.78 21 9 119 F 441 71 238 3638 82150 1200 HXR 355LA6 8684 1188 93.0 92.5 0.79 0.74 22 10 109 F 664 68 225 3616 80200 3600 HXR 355LA2 92 3572 92.5 91.7 0.89 0.87 26 7 160 F 294 66 258 3505 89200 1800 HXR 355LA4 203 1787 93.1 92.4 0.82 0.77 28 12 183 H 587 100 247 3417 82200 1200 HXR 355LA6 318 1189 93.3 92.9 0.79 0.74 29 13 153 F 883 98 203 3616 80200 900 HXR 400LA8 424 890 93.7 93.7 0.77 0.73 30 13 130 D 1179 79 178 5093 75200 600 HXR 400LD12 598 594 92.8 92.5 0.68 0.62 34 19 138 E 1767 84 176 5908 75250 3600 HXR 355LA2 93 3568 93.0 92.5 0.90 0.88 32 9 204 G 367 67 268 3417 89250 1800 HXR 355LA4 204 1785 93.5 93.1 0.83 0.79 35 14 216 G 734 98 239 3439 82250 1200 HXR 355LA6 319 1187 93.7 93.5 0.79 0.75 36 15 187 F 1103 103 190 3594 80250 900 HXR 400LB8 425 890 94.1 94.2 0.78 0.74 37 16 158 D 1472 79 172 5357 75250 720 HXR 400LD10 512 714 93.5 93.1 0.71 0.64 41 23 197 F 1834 90 200 5776 79250 600 HXR 400LF12 599 594 93.1 92.9 0.69 0.63 42 23 170 E 2206 84 172 6327 75300 3600 HXR 355LA2 94 3573 93.7 93.4 0.90 0.88 38 10 247 G 442 70 260 3616 89300 1800 HXR 355LA4 205 1783 93.8 93.6 0.84 0.81 41 15 234 F 885 91 214 3439 82300 1200 HXR 355LB6 320 1187 94.1 94.0 0.80 0.76 43 18 222 F 1329 104 185 3814 80300 900 HXR 400LD8 426 890 94.4 94.5 0.78 0.74 44 19 195 D 1772 83 176 5776 75300 720 HXR 400LD10 513 714 93.5 93.2 0.72 0.66 48 26 224 F 2210 86 186 5908 80300 600 HXR 400LH12 600 594 93.5 93.2 0.69 0.62 50 28 210 E 2656 87 177 7033 75350 3600 HXR 355LB2 95 3571 94.1 93.9 0.91 0.90 44 10 263 F 515 66 237 3814 89350 1800 HXR 355LA4 206 1786 94.4 94.2 0.85 0.81 47 17 301 G 1029 99 230 3638 82350 1200 HXR 355LC6 321 1190 94.6 94.5 0.80 0.76 50 21 261 F 1545 89 199 4057 80350 900 HXR 400LE8 427 890 94.6 94.8 0.79 0.75 51 21 220 D 2065 81 170 6063 75350 720 HXR 400LF10 514 714 93.8 93.5 0.72 0.65 56 30 272 F 2574 91 193 6482 80350 600 HXR 450LG12 601 595 94.2 93.9 0.69 0.63 58 32 245 E 3090 77 182 8841 75400 3600 HXR 355LC2 96 3570 94.4 94.3 0.90 0.89 50 12 309 F 588 64 241 4034 89400 1800 HXR 355LB4 207 1786 94.7 94.6 0.85 0.82 54 19 342 G 1175 100 228 3748 82400 1200 HXR 355LD6 322 1189 94.8 94.8 0.81 0.78 56 22 299 F 1765 95 198 4255 80400 900 HXR 400LG8 428 891 94.8 94.9 0.79 0.75 58 24 270 E 2356 89 181 6570 75400 720 HXR 400LH10 515 714 94.0 93.8 0.73 0.67 63 33 299 F 2940 89 188 6900 80400 600 HXR 450LH12 602 595 94.3 94.0 0.70 0.63 65 36 279 E 3528 77 180 9370 75450 3600 HXR 355LD2 97 3573 94.8 94.7 0.92 0.90 56 13 365 G 662 66 261 4233 89450 1800 HXR 355LC4 208 1788 95.0 94.9 0.85 0.82 60 21 374 G 1324 99 207 3990 82450 1200 HXR 355LE6 323 1190 95.0 95.0 0.82 0.78 63 25 340 F 1989 97 198 4475 80450 900 HXR 400LH8 429 890 95.0 95.1 0.79 0.76 65 26 288 D 2658 85 172 6900 75450 720 HXR 400LK10 516 714 94.2 94.0 0.73 0.68 70 36 331 F 3315 87 184 7452 80450 600 HXR 450LK12 603 595 94.5 94.2 0.70 0.63 74 41 320 E 3977 79 184 10075 75500 3600 HXR 400LD2 98 3581 94.9 94.5 0.90 0.89 63 16 436 G 734 61 276 5886 88500 1800 HXR 355LD4 209 1788 95.2 95.2 0.85 0.82 66 23 423 G 1469 103 209 4189 82500 1200 HXR 400LD6 324 1191 95.4 95.4 0.83 0.79 68 26 389 F 2206 89 210 5975 79500 900 HXR 400LH8 430 891 94.7 94.8 0.79 0.75 72 29 325 D 2950 87 173 6989 78500 720 HXR 450LF10 517 714 95.2 95.3 0.76 0.71 74 35 361 E 3679 84 187 8554 76500 600 HXR 450LN12 604 595 94.6 94.2 0.69 0.63 82 46 368 F 4413 82 191 11133 75600 3600 HXR 400LE2 99 3581 95.3 95.0 0.91 0.89 75 19 525 G 881 64 269 6173 88600 1800 HXR 400LC4 210 1790 95.7 95.6 0.88 0.85 77 24 483 F 1763 81 223 5820 80600 1200 HXR 400LE6 325 1191 95.5 95.6 0.83 0.80 81 30 455 F 2650 88 202 6217 79600 900 HXR 450LE8 431 893 95.3 95.3 0.83 0.80 82 31 450 F 3533 87 213 8289 76600 720 HXR 450LH10 518 714 95.4 95.5 0.76 0.71 89 43 453 F 4417 90 196 9281 76600 600 HXR 500LJ12 605 595 94.6 94.4 0.71 0.66 96 49 404 E 5307 77 170 13250 75
4000 V 60 HzHV Cast iron motors, standardTechnical data for totally enclosed squirrel cage three phase motors TEFC – Insulation class F, temperature rise class B, S.F. 1.0
Data presented in rating lists are typical values. Guaranteed values on request. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
IEC frame size NEMA frame size
355 58xx400 68xx450 72xx500 80xx560 88xx
22 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
4000 V 60 HzHV Cast iron motors, standardTechnical data for totally enclosed squirrel cage three phase motors TEFC – Insulation class F, temperature rise class B, S.F. 1.0
Data presented in rating lists are typical values. Guaranteed values on request. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
IEC frame size NEMA frame size
355 58xx400 68xx450 72xx500 80xx560 88xx
4000 V 60 Hz700 3600 HXR 400LG2 100 3582 95.6 95.4 0.91 0.89 87 21 614 G 1026 65 265 6548 88700 1800 HXR 400LE4 211 1790 95.9 95.9 0.88 0.87 89 25 567 F 2054 88 220 6217 80700 1200 HXR 400LH6 326 1192 95.8 95.8 0.83 0.79 95 36 564 F 3086 94 213 6923 79700 900 HXR 450LG8 432 893 95.2 95.2 0.83 0.80 95 35 527 F 4116 89 213 8995 82700 720 HXR 450LK10 519 714 95.4 95.5 0.77 0.72 103 47 510 F 5148 87 189 9811 78700 600 HXR 500LM12 606 595 94.6 94.3 0.71 0.66 112 58 489 E 6181 81 175 14330 75800 3600 HXR 450LG2 101 3584 95.4 95.1 0.91 0.90 99 24 697 G 1173 64 279 8929 91800 1800 HXR 400LF4 212 1790 96.0 96.1 0.89 0.87 101 28 648 F 2349 87 217 6570 80800 1200 HXR 450LE6 327 1192 95.9 96.1 0.88 0.86 102 29 589 F 3527 85 200 8378 80800 900 HXR 450LH8 433 893 95.4 95.4 0.84 0.81 108 38 587 F 4708 87 201 9348 82800 720 HXR 450LM10 520 714 95.5 95.6 0.77 0.73 117 53 575 E 5888 87 186 10516 78800 600 HXR 500LP12 607 595 94.7 94.5 0.72 0.67 126 62 532 E 7073 77 168 15190 75900 3600 HXR 450LK2 102 3582 95.6 95.4 0.93 0.92 109 23 749 G 1319 60 276 9766 91900 1800 HXR 400LH4 213 1791 96.2 96.2 0.88 0.85 115 34 737 G 2639 82 219 7011 80900 1200 HXR 450LG6 328 1193 96.1 96.2 0.87 0.85 115 35 718 F 3961 92 214 9039 80900 900 HXR 450LM8 434 894 95.6 95.5 0.84 0.81 120 43 693 F 5289 94 218 10759 82900 720 HXR 500LL10 521 715 95.9 96.0 0.78 0.74 129 55 631 E 6613 77 188 13911 78900 600 HXR 500LR12 608 595 94.8 94.6 0.72 0.67 141 69 599 E 7949 78 168 16072 751000 3600 HXR 500LH2 103 3588 95.4 95.0 0.91 0.89 124 32 899 G 1464 56 290 12831 911000 1800 HXR 450LH4 214 1791 96.2 96.2 0.89 0.88 125 33 799 F 2933 80 224 9480 821000 1200 HXR 450LJ6 329 1193 96.2 96.3 0.88 0.86 127 36 780 F 4404 91 210 9744 801000 900 HXR 500LL8 435 895 96.1 96.1 0.83 0.80 134 50 773 F 5868 82 207 13955 771000 720 HXR 500LN10 522 715 96.0 96.0 0.79 0.74 143 62 722 E 7350 81 193 14991 781250 3600 HXR 500LM2 104 3587 95.9 95.6 0.93 0.92 151 33 1074 G 1830 60 280 14462 911250 1800 HXR 450LL4 215 1791 96.4 96.5 0.89 0.88 156 40 1007 F 3664 83 221 10362 821250 1200 HXR 500LG6 330 1194 96.3 96.3 0.86 0.83 162 53 994 F 5498 82 217 12434 821250 900 HXR 500LN8 436 896 96.2 96.2 0.83 0.80 168 63 987 F 7330 86 208 14947 771250 720 HXR 500LR10 523 715 95.8 95.9 0.79 0.76 177 72 858 E 9187 78 183 16204 801500 3600 HXR 500LQ2 105 3589 96.2 95.9 0.91 0.90 184 44 1361 G 2196 60 279 15454 911500 1800 HXR 500LJ4 216 1792 96.4 96.5 0.89 0.88 187 50 1210 F 4399 77 233 13140 821500 1200 HXR 500LK6 331 1194 96.4 96.5 0.87 0.85 193 59 1185 F 6602 85 213 13735 821500 900 HXR 500LS8 437 896 96.4 96.3 0.83 0.80 202 76 1216 G 8798 88 214 17108 771750 1800 HXR 500LL4 217 1792 96.6 96.7 0.90 0.88 217 56 1386 F 5134 77 226 14286 821750 1200 HXR 500LP6 332 1194 96.6 96.7 0.87 0.84 225 69 1379 F 7702 83 213 15454 822000 1800 HXR 500LR4 218 1793 96.8 96.8 0.89 0.87 250 69 1604 F 5861 72 228 16424 82
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 23
1
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
HV Modular induction motors, standardDimension drawings Antifriction bearings, 2300 < U ≤ 6900 V, F1/F2, WPII
AMA Poles 2E 2F BA N-W H G U F R SR D C O FP
IEC NEMA
400L 68xx 2 29.53 49.21 7.87 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 73.62 67.3 63.8
400L 68xx ≥ 4 29.53 49.21 7.87 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 75.20 67.3 63.8
450L 72xx 2 33.47 55.12 7.87 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 79.53 73.2 67.7
450L 72xx ≥ 4 33.47 55.12 7.87 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 81.10 73.2 67.7
500L 80xx ≥ 4 37.40 62.99 7.87 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 90.55 81.1 71.7
AMA Poles A B K FK J AB AC AE AF FDS BS
IEC NEMA
400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
400L 68xx ≥ 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
450L 72xx ≥ 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
500L 80xx ≥ 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
AMA Poles D-end bearing N-end bearing
IEC NEMA
400L 68xx 2 6319M/C3 6319M/C3
400L 68xx ≥ 4 6324/C3 6319/C3
450L 72xx 2 6319M/C3 6319M/C3
450L 72xx ≥ 4 6326/C3 6322/C3
500L 80xx ≥ 4 6330/C3 6324/C3
24 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
HV Modular induction motors, standardDimension drawings Sleeve bearings, 2300 < U ≤ 6900 V, F1/F2, WPII
AMA Poles 2E 2F BA N-W H G U F R SR D C O FP
IEC NEMA
400L 68xx 2 29.53 49.21 14.76 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 81.30 67.3 63.8
400L 68xx ≥ 4 29.53 49.21 14.76 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 82.68 67.3 63.8
450L 72xx 2 33.47 55.12 14.76 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 87.21 73.2 67.7
450L 72xx ≥ 4 33.47 55.12 15.75 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 89.57 73.2 67.7
500L 80xx 2 37.40 62.99 14.76 8.268 1.65 1.38 4.331 1.102 3.937 0.630 19.69 97.84 81.1 71.7
500L 80xx ≥ 4 37.40 62.99 17.72 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 102.17 81.1 71.7
AMA Poles A B K FK J AB AC AE AF FDS BS
IEC NEMA
400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
400L 68xx ≥ 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
450L 72xx ≥ 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
500L 80xx 2 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
500L 80xx 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
500L 80xx ≥ 6 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
AMA Poles D-end bearing N-end bearing
IEC NEMA
400L 68xx 2 EFZLB9-80 EFZLQ9-80
400L 68xx ≥ 4 EFZLB9-100 EFZLQ9-100
450L 72xx 2 EFZLB9-80 EFZLQ9-80
450L 72xx ≥ 4 EFZLB11-125 EFZLQ9-100
500L 80xx 2 EFNLB11-90 EFNLB11-90
500L 80xx 4 EFZLB14-125 EFZLQ11-125
500L 80xx ≥ 6 EFZLB14-140 EFZLQ11-125
Note! Includes provision for BN proximity probes.
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 25
1
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
AMA Poles AB AC AD AF AJ AK BB BD BE BF BV C
IEC NEMA
400L 68xx ≥ 4 42.2 34.1 1.97 18.4 42.52 39.37 0.236 44.49 1.181 1.102 49.0 75.4
450L 72xx ≥ 4 44.2 36.0 1.97 18.4 46.46 44.09 0.276 48.43 1.575 1.102 54.9 81.3
500L 80xx ≥ 4 46.2 38.0 1.97 18.4 51.97 49.21 0.315 53.94 1.850 1.102 62.8 90.7
AMA Poles FDS N-W P R S T U U-R D-end bearing N-end bearing
IEC NEMA
400L 68xx ≥ 4 17.5 8.268 73.8 3.937 1.102 3.15 4.331 0.630 6324/C3 7319B
450L 72xx ≥ 4 21.3 8.268 79.7 4.488 1.260 3.15 4.921 0.709 6326/C3 7322B
500L 80xx ≥ 4 24.0 9.843 88.4 5.039 1.417 3.15 5.512 0.787 6330/C3 7324B
HV Modular induction motors, standardDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, WPII, vertical
26 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
HV Cast iron motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEFC, F1
Motor type
Poles 2E 2F BA U N-W F D FP O C H FDS BS
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 10.00 2.750 5.500 0.625 14.50 54.9 57.1 59.5 1.38 27.6 0.7
HXR 355L 58xx ≥ 4 25.00 25.00 10.00 4.000 8.250 1.000 14.50 54.9 57.1 65.7 1.38 27.6 0.7
HXR 400L 68xx 2 28.00 36.00 9.00 3.125 6.500 0.750 17.00 54.9 61.3 69.1 1.38 35.2 1.3
HXR 400L 68xx ≥ 4 28.00 36.00 9.00 4.375 8.250 1.000 17.00 54.9 61.3 74.6 1.38 35.2 1.3
HXR 450L 72xx 2 32.00 40.00 10.00 3.125 6.500 0.750 18.00 61.8 64.3 78.0 1.65 42.3 0.8
HXR 450L 72xx ≥ 4 32.00 40.00 10.00 4.375 8.250 1.000 18.00 61.8 64.3 83.5 1.65 42.3 0.8
HXR 500L 80xx 2 36.00 50.00 11.00 3.500 6.500 0.875 20.00 61.8 69.3 91.1 1.65 52.8 0.4
HXR 500L 80xx ≥ 4 36.00 50.00 11.00 4.750 8.250 1.250 20.00 61.8 69.3 96.7 1.65 52.8 0.4
HXR 560L 88xx ≥ 4 40.00 63.00 16.00 6.250 12.00 1.500 22.00 61.8 74.6 119.3 1.89 67.7 3.0
Motor type
Poles J A P K B G D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 4.9 28.0 29.5 8.3 34.9 2.7 6317M/C3 6317M/C3
HXR 355L 58xx ≥ 4 4.9 28.0 29.5 8.3 34.9 2.7 6322/C3 6319/C3
HXR 400L 68xx 2 5.5 33.1 33.1 10.0 44.1 2.6 6317M/C3 6317M/C3
HXR 400L 68xx ≥ 4 5.5 33.1 33.1 10.0 44.1 2.6 6324/C3 6319/C3
HXR 450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.86 6317M/C3 6317M/C3
HXR 450L 72xx ≥ 4 6.3 37.4 37.0 12.6 51.2 1.86 6324/C3 6322/C3
HXR 500L 80xx 2 6.7 41.2 41.5 14.8 61.8 2.1 6319M/C3 6319M/C3
HXR 500L 80xx ≥ 4 6.7 41.2 41.5 14.8 61.8 2.1 6326/C3 6324/C3
HXR 560L 88xx ≥ 4 9.1 46.1 46.9 24.4 76.4 1.9 6034/C3 + NU1034/C3 NU322/C3
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 27
1
HV Cast iron motors, engineeredDimension drawings Sleeve bearings, 1000 < U ≤ 6900 V, TEFC, F1
Motor type
Poles 2E 2F BA U N-W F D FP O C H FDS BS
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 19.00 2.750 5.500 0.625 14.50 54.9 57.1 75.4 1.38 27.6 0.67
HXR 355L 58xx ≥ 4 25.00 25.00 19.00 4.000 8.250 1.000 14.50 54.9 57.1 81.9 1.38 27.6 0.67
HXR 400L 68xx 2 28.00 36.00 18.00 3.125 6.500 0.750 17.00 54.9 61.3 85.2 1.38 35.3 1.3
HXR 400L 68xx ≥ 4 28.00 36.00 18.00 4.375 8.250 1.000 17.00 54.9 61.3 90.7 1.38 35.3 1.3
HXR 450L 72xx 2 32.00 40.00 19.00 3.125 6.500 0.750 18.00 61.8 64.3 94.1 1.65 42.3 0.8
HXR 450L 72xx ≥ 4 32.00 40.00 19.00 4.375 8.250 1.000 18.00 61.8 64.3 99.6 1.65 42.3 0.8
HXR 500L 80xx 2 36.00 50.00 20.00 3.500 6.500 0.875 20.00 61.8 69.3 106.7 1.65 52.8 0.4
HXR 500L 80xx ≥ 4 36.00 50.00 20.00 4.750 8.250 1.250 20.00 61.8 69.3 112.2 1.65 52.8 0.4
HXR 560L 88xx ≥ 4 40.00 63.00 26.50 6.250 12.00 1.500 22.00 61.8 74.6 136.4 1.89 67.7 2.8
Motor type
Poles J A P K B G D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 355L 58xx ≥ 4 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-90 EFZLQ 9-90
HXR 400L 68xx 2 5.5 33.1 33.1 10.0 44.1 2.6 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 400L 68xx ≥ 4 5.5 33.1 33.1 10.0 44.1 2.6 EFZLB 9-100 EFZLQ 9-100
HXR 450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 450L 72xx ≥ 4 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-100 2) EFZLQ 9-100 2)
HXR 500L 80xx 2 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 9-90 1) EFZLQ 9-90 1)
HXR 500L 80xx ≥ 4 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 11-100 2) EFZLQ 9-100 2)
HXR 560L 88xx 4, 6 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-125 2) EFZLQ 14-125 2)
HXR 560L 88xx ≥ 4 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-140 EFZLQ 14-140
Note! Includes provision for BN proximity probes.Note! Axial float of rotor as standard ±0.31 inch.Note! The bearing can not withstand continuous axial forces.
1) With oil circulation as standard, see PIF 2a-3210 for pipe connections. 2) With oil circulation as standard for 4 poles, see PIF 2a-3210 for pipe connections.
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
28 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
HV Cast iron motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEFC, F2
Motor type
Poles 2E 2F BA U N-W F D FP O C H FDS BS
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 10.00 2.750 5.500 0.625 14.50 54.9 57.1 59.3 1.38 27.6 0.7
HXR 355L 58xx ≥ 4 25.00 25.00 10.00 4.000 8.250 1.000 14.50 54.9 57.1 65.7 1.38 27.6 0.7
HXR 400L 68xx 2 28.00 36.00 9.00 3.125 6.500 0.750 17.00 54.9 61.3 69.1 1.38 35.2 1.3
HXR 400L 68xx ≥ 4 28.00 36.00 9.00 4.375 8.250 1.000 17.00 54.9 61.3 74.6 1.38 35.2 1.3
HXR 450L 72xx 2 32.00 40.00 10.00 3.125 6.500 0.750 18.00 61.8 64.3 78.0 1.65 42.3 0.8
HXR 450L 72xx ≥ 4 32.00 40.00 10.00 4.375 8.250 1.000 18.00 61.8 64.3 83.5 1.65 42.3 0.8
HXR 500L 80xx 2 36.00 50.00 11.00 3.500 6.500 0.875 20.00 61.8 69.3 91.1 1.65 52.8 0.4
HXR 500L 80xx ≥ 4 36.00 50.00 11.00 4.750 8.250 1.250 20.00 61.8 69.3 96.7 1.65 52.8 0.4
HXR 560L 88xx ≥ 4 40.00 63.00 16.00 6.250 12.00 1.500 22.00 61.8 74.6 119.3 1.89 67.7 3.0
Motor type
Poles J A P K B G D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 4.9 28.0 29.5 8.3 34.9 2.7 6317M/C3 6317M/C3
HXR 355L 58xx ≥ 4 4.9 28.0 29.5 8.3 34.9 2.7 6322/C3 6319/C3
HXR 400L 68xx 2 5.5 33.1 33.1 10.0 44.1 2.6 6317M/C3 6317M/C3
HXR 400L 68xx ≥ 4 5.5 33.1 33.1 10.0 44.1 2.6 6324/C3 6319/C3
HXR 450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.85 6317M/C3 6317M/C3
HXR 450L 72xx ≥ 4 6.3 37.4 37.0 12.6 51.2 1.85 6324/C3 6322/C3
HXR 500L 80xx 2 6.7 41.2 41.5 14.8 61.8 2.1 6319M/C3 6319M/C3
HXR 500L 80xx ≥ 4 6.7 41.2 41.5 14.8 61.8 2.1 6326/C3 6324/C3
HXR 560L 88xx ≥ 4 9.1 46.1 46.9 24.5 76.4 1.9 6034/C3 + NU1034/C3 NU322/C3
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 29
1
HV Cast iron motors, engineeredDimension drawings Sleeve bearings, 1000 < U ≤ 6900 V, TEFC, F2
Motor type
Poles 2E 2F BA U N-W F D FP O C H FDS BS
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 19.00 2.750 5.500 0.625 14.50 54.9 57.1 75.4 1.38 27.6 0.67
HXR 355L 58xx ≥ 4 25.00 25.00 19.00 4.000 8.250 1.000 14.50 54.9 57.1 81.9 1.38 27.6 0.67
HXR 400L 68xx 2 28.00 36.00 18.00 3.125 6.500 0.750 17.00 54.9 61.3 85.2 1.38 35.3 1.3
HXR 400L 68xx ≥ 4 28.00 36.00 18.00 4.375 8.250 1.000 17.00 54.9 61.3 90.7 1.38 35.3 1.3
HXR 450L 72xx 2 32.00 40.00 19.00 3.125 6.500 0.750 18.00 61.8 64.3 94.1 1.65 42.3 0.8
HXR 450L 72xx ≥ 4 32.00 40.00 19.00 4.375 8.250 1.000 18.00 61.8 64.3 99.6 1.65 42.3 0.8
HXR 500L 80xx 2 36.00 50.00 20.00 3.500 6.500 0.875 20.00 61.8 69.3 106.7 1.65 52.8 0.4
HXR 500L 80xx ≥ 4 36.00 50.00 20.00 4.750 8.250 1.250 20.00 61.8 69.3 112.2 1.65 52.8 0.4
HXR 560L 88xx ≥ 4 40.00 63.00 26.50 6.250 12.00 1.500 22.00 61.8 74.6 136.4 1.89 67.7 2.8
Motor type
Poles J A P K B G D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 355L 58xx ≥ 4 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-90 EFZLQ 9-90
HXR 400L 68xx 2 5.5 33.1 33.1 10.0 44.1 2.6 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 400L 68xx ≥ 4 5.5 33.1 33.1 10.0 44.1 2.6 EFZLB 9-100 EFZLQ 9-100
HXR 450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 450L 72xx ≥ 4 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-100 2) EFZLQ 9-100 2)
HXR 500L 80xx 2 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 9-90 1) EFZLQ 9-90 1)
HXR 500L 80xx ≥ 4 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 11-100 2) EFZLQ 9-100 2)
HXR 560L 88xx 4, 6 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-125 2) EFZLQ 14-125 2)
HXR 560L 88xx ≥ 4 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-140 EFZLQ 14-140
Note! Includes provision for BN proximity probes.Note! Axial float of rotor as standard ±0.31 inch.Note! The bearing can not withstand continuous axial forces.
1) With oil circulation as standard, see PIF 2a-3210 for pipe connections. 2) With oil circulation as standard for 4 poles, see PIF 2a-3210 for pipe connections.
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
30 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
HV Cast iron motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEFC, F1, flange mounting
Motor type
Poles 2E 2F A AB AC AE AF AJ AK B BA BB BD
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50HXR 355L 58xx ≥ 4 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50
HXR 400L 68xx 2 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37HXR 400L 68xx ≥ 4 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37HXR 450L 72xx 2 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28HXR 450L 72xx ≥ 4 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28HXR 500L 80xx 2 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28HXR 500L 80xx ≥ 4 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28HXR 560L 88xx ≥ 4 40.00 63.00 46.1 40.7 32.4 53.5 18.4 51.97 49.21 76.4 16.00 0.236 55.12
Motor type
Poles BE BF BS C D EV F FDS G H J K
IEC NEMA
HXR 355L 58xx 2 0.984 0.945 27.0 59.3 14.50 4.2 0.625 0.55 2.68 1.38 4.9 8.3HXR 355L 58xx ≥ 4 0.984 0.945 27.0 65.7 14.50 4.2 1.000 0.55 2.68 1.38 4.9 8.3HXR 400L 68xx 2 1.181 1.102 36.2 69.1 17.00 3.4 0.750 0.95 2.64 1.38 5.5 10.0HXR 400L 68xx ≥ 4 1.181 1.102 36.2 74.6 17.00 3.4 1.000 0.95 2.64 1.38 5.5 10.0HXR 450L 72xx 2 1.181 1.102 43.0 78.0 18.00 3.7 0.750 0.63 1.85 1.65 6.3 12.6HXR 450L 72xx ≥ 4 1.181 1.102 43.0 83.5 18.00 3.7 1.000 0.63 1.85 1.65 6.3 12.6HXR 500L 80xx 2 1.181 1.102 53.6 91.1 20.00 3.9 0.875 0.83 2.09 1.65 6.7 14.8HXR 500L 80xx ≥ 4 1.181 1.102 53.6 96.7 20.00 3.9 1.250 0.83 2.09 1.65 6.7 14.8HXR 560L 88xx ≥ 4 2.362 1.102 65.5 119.3 22.00 6.9 1.500 2.21 1.93 1.89 9.1 24.4
Motor type
Poles N-W O P U D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 5.500 57.1 29.5 2.750 6317/C3 6317/C3HXR 355L 58xx ≥ 4 8.250 57.1 29.5 4.000 6322/C3 6319/C3HXR 400L 68xx 2 6.500 61.3 33.1 3.125 6317/C3 6317/C3HXR 400L 68xx ≥ 4 8.250 61.3 33.1 4.375 6324/C3 6319/C3HXR 450L 72xx 2 6.500 64.3 37.0 3.125 6317/C3 6317/C3HXR 450L 72xx ≥ 4 8.250 64.3 37.0 4.375 6324/C3 6322/C3HXR 500L 80xx 2 6.500 69.3 40.9 3.500 6319M/C3 6319M/C3HXR 500L 80xx ≥ 4 8.250 69.3 40.9 4.750 6326/C3 6324/C3HXR 560L 88xx ≥ 4 12.00 74.6 46.9 6.250 6034/C3 + NU1034/C3 NU322/C3
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 31
1
HV Cast iron motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEFC, F2, flange mounting
Motor type
Poles 2E 2F A AB AC AE AF AJ AK B BA BB BD
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50HXR 355L 58xx ≥ 4 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50HXR 400L 68xx 2 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37HXR 400L 68xx ≥ 4 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37HXR 450L 72xx 2 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28HXR 450L 72xx ≥ 4 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28HXR 500L 80xx 2 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28HXR 500L 80xx ≥ 4 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28HXR 560L 88xx ≥ 4 40.00 63.00 46.1 40.7 32.4 53.5 18.4 51.97 49.21 76.4 16.00 0.236 55.12
Motor type
Poles BE BF BS C D EV F FDS G H J K
IEC NEMA
HXR 355L 58xx 2 0.984 0.945 27.0 59.3 14.50 4.2 0.625 0.55 2.68 1.38 4.9 8.3HXR 355L 58xx ≥ 4 0.984 0.945 27.0 65.7 14.50 4.2 1.000 0.55 2.68 1.38 4.9 8.3HXR 400L 68xx 2 1.181 1.102 36.2 69.1 17.00 3.4 0.750 0.95 2.64 1.38 5.5 10.0HXR 400L 68xx ≥ 4 1.181 1.102 36.2 74.6 17.00 3.4 1.000 0.95 2.64 1.38 5.5 10.0HXR 450L 72xx 2 1.181 1.102 43.0 78.0 18.00 3.7 0.750 0.63 1.85 1.65 6.3 12.6HXR 450L 72xx ≥ 4 1.181 1.102 43.0 83.5 18.00 3.7 1.000 0.63 1.85 1.65 6.3 12.6HXR 500L 80xx 2 1.181 1.102 53.6 91.1 20.00 3.9 0.875 0.83 2.09 1.65 6.7 14.8HXR 500L 80xx ≥ 4 1.181 1.102 53.6 96.7 20.00 3.9 1.250 0.83 2.09 1.65 6.7 14.8HXR 560L 88xx ≥ 4 2.362 1.102 65.5 119.3 22.00 6.9 1.500 2.21 1.93 1.89 9.1 24.4
Motor type
Poles N-W O P U D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 5.500 57.1 29.5 2.750 6317/C3 6317/C3HXR 355L 58xx ≥ 4 8.250 57.1 29.5 4.000 6322/C3 6319/C3HXR 400L 68xx 2 6.500 61.3 33.1 3.125 6317/C3 6317/C3HXR 400L 68xx ≥ 4 8.250 61.3 33.1 4.375 6324/C3 6319/C3HXR 450L 72xx 2 6.500 64.3 37.0 3.125 6317/C3 6317/C3HXR 450L 72xx ≥ 4 8.250 64.3 37.0 4.375 6324/C3 6322/C3HXR 500L 80xx 2 6.500 69.3 40.9 3.500 6319M/C3 6319M/C3HXR 500L 80xx ≥ 4 8.250 69.3 40.9 4.750 6326/C3 6324/C3HXR 560L 88xx ≥ 4 12.00 74.6 46.9 6.250 6034/C3 + NU1034/C3 NU322/C3
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
32 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
HV Cast iron motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEFC, vertical
Motor type
Poles AB AC AF AJ AK BB BD BE BF BV C F
IEC NEMA
HXR 355L 58xx ≥ 4 41.00 32.70 18.40 29.13 26.77 0.236 31.50 0.984 0.945 37.00 65.70 1.000
HXR 400L 68xx ≥ 4 42.70 34.45 18.40 37.00 34.65 0.236 39.37 1.181 1.102 45.20 74.60 1.000
HXR 450L 72xx ≥ 4 44.70 36.40 18.40 42.52 39.37 0.236 45.28 1.181 1.102 52.95 83.50 1.000
HXR 500L 80xx ≥ 4 47.60 39.40 18.40 42.52 39.37 0.236 45.28 1.181 1.102 64.60 96.70 1.250
HXR 560L 88xx ≥ 6 51.00 42.70 18.40 51.97 49.21 0.236 55.12 1.575 1.102 80.70 118.5 1.500
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.Rain canopy is recommended for outdoor location.
Motor type
Poles FDS N-W P U D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx ≥ 4 10.0 8.250 29.5 4.000 6322/C3 7319 BM
HXR 400L 68xx ≥ 4 10.0 8.250 33.1 4.375 6324/C3 7319 BM
HXR 450L 72xx ≥ 4 10.6 8.250 37.0 4.375 6324/C3 7322 BM
HXR 500L 80xx ≥ 4 11.8 8.250 40.9 4.750 6326/C3 7324 BM
HXR 560L 88xx ≥ 6 13.0 12.00 46.9 6.250 6034/C3 7334 BM
ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009 33
1
The picture shows high voltage terminal box with its main technical data below.
Technical data:
Voltage (max.) 6.9 kVCurrent (max.) 600 ANo of cables (max.) 2 per phaseCable gland blind gland (1 pce)Connection hooks 0.3" x 2.36" (3 pcs)Clearance (min.) 5.9 inCreepage (min.) 10 inUsable volume 18 000 in3
Ground connections M16 (both in- and outside)Weight 230 lbsProtection NEMA 4Standard NEMA MG 1, Part 20
Materials: Box welded sheet steel (thickness min. 0.12") Cable gland plate steel Connection hooks Copper Cu Isolators epoxy casting resin Grounding pad stainless steel
Other features:
- rigid welded construction- ample size for making connections of supply cables- box turnable to allow cable entry from left or right side- box turnable in steps of 90°- either 3-phase or 1-phase cables can be connected- all removable cover plates are bolted and gasketed- different cable glands available.
NEMA type II terminal box (normal size)
Figure above: High voltage NEMA Type II terminal box (normal size). Dimensions in inches [mm].
34 ABB /BU Machines/NEMA catalogue/Standard motors, AMA & HXR EN 02-2009
1
The picture shows high voltage terminal box with its main technical data below.
Technical data:Voltage (max.) 6.9 kVCurrent (max.) 600 ANo of cables (max.) 2 per phaseCable gland blind gland (1 pce)Connection hooks 0.3" x 2.36" (3 pcs)Clearance (min.) 5.9 inCreepage (min.) 10 inUsable volume 36 000 in3 Ground connections M16 (both in- and outside)Weight 375 lbsProtection NEMA 4Standard NEMA MG 1, Part 20
Materials: Box welded sheet steel (thickness min. 0.12") Cable gland plate steel Connection hooks Copper Cu Isolators epoxy casting resin Grounding pad stainless steel
Other features:- rigid welded construction- ample size for making connections of supply cables- box turnable to allow cable entry from left or right side- box turnable in steps of 90°- either 3-phase or 1-phase cables can be connected- all removable cover plates are bolted and gasketed- different cable glands available- can be equipped with: current transformer (CT), lightning arrester (LA), surge capasitor (SC)
NEMA type II terminal box (over size)
Figure above: High voltage NEMA Type II terminal box (over size). Dimensions in inches [mm].
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 35
2
Standard NEMA Motors, cast iron frame
Totally enclosed squirrel cage three phase high voltage motors, Sizes 506AT - 728, 150 to 950 HP
Contents...............................................Page
Mechanical design............................36
Ordering information........................46
Rating plates.....................................47
Technical data...................................48
Variant codes....................................52
Dimension drawings........................54
Accessories......................................57
Construction.....................................58
Motors in brief...................................59
ABB reserves the right to change the design, technical specification and dimensions without prior notice.
36 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
Stator frameThe motor frames feature integrally cast feet to provide a very rigid mounting and minimal vibration; the feet and bearing housing are made of cast iron.
All the high voltage motors are fitted with drain holes and closable plugs. The drain hole plugs are open on delivery and users must ensure that the drain holes face downward when mounting the motors.
Drain holes
Motors can be supplied for foot mounting (F1 & F2) or foot and flange mounting. The terminal box is made of structural steel.
Motor sizes 506AT-728As standard with drain holes and closable plugs.
Mechanical design
In very dusty environ ments, both plugs should be hammered home.
These motors in this section are standard NEMA cast iron motors with limited optional features and accessories.
In case you need an engineered cast iron NEMA motor, please see section 3 for further information.
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 37
2
NEMA terminal boxes for M3BM and M3GM motors.
Type ITechnical data:
Voltage (max.) 4.8 kVCurrent (max.) 700 ANo of cables (max.) 2 per phaseCross section of cables (max.) 300 mm2/cable (0.465 in2)Cable gland blind gland (1 pce)Gross volume 98.3 dm3 (6000 in3)
Ground connections M12 (inside)Weight 42 kg (92 lbs)Protection IP 66Standard NEMA MG 1, Part 20
Terminal boxes
Materials:
Box welded sheet steel (thickness min. 3 mm (0.12"))Cable gland plate steelGrounding pad stainless steel
Other features:
- rigid welded construction- box turnable to allow cable entry from left or right side- box turnable in steps of 90°.
Type I terminal box.
38 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
Type II terminal box.
Type II
Technical data:
Voltage (max.) 6.9 kVCurrent (max.) 600 ANo of cables (max.) 2 per phaseCross section of cables (max.) 300 mm2/cable (0.465 in2)Cable gland blind gland (1 pce)Connection hooks 0.3" x 2.36" (3 pcs)Clearance (min.) 149.8 mm (5.9 in)Creepage (min.) 249 mm (10 in)Usable volume 0.295 m3 (18 000 in3)Ground connections M16 (both in- and outside)Weight 105 kg (230 lbs)Protection IP 66Standard NEMA MG 1, Part 20
Materials: Box welded sheet steel (thickness min. 3 mm (0.12")) Cable gland plate steel Connection hooks Copper Cu Isolators epoxy casting resin Grounding pad stainless steel
Other features:
- rigid welded construction- ample size for making connections of supply cables- box turnable to allow cable entry from left or right side- box turnable in steps of 90°.
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 39
2
Dimensions for terminal box inlet, blind flange
Type I
Type II
40 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
Auxiliary boxes
- one box as default - stator Pt-100 - bearing Pt-100 (optional, variant code 107) - heating element (optional, variant code 450/451)- separate auxiliary box for heating element (optional, variant code 447)
Specification:
Material designation Al-Si10Mg (pressure die cast)Material standard EN 573-3Surface treatment RAL 7001 (grey)
Other features:
- equipped with assembly rail ARH 22 (DIN-35, 35 x 203 mm (1.38" x 7.99"))- main dimensions 125 mm x 222 mm x 81 mm (4.92" x 8.74" x 3.19")- cable gland M20- degree of protection IP 66 (IEC 529)- gasket material polyurethane- temperature resistance -55 - +80 °C - max. terminal blocks: 34 pcs 0.004 in2 (2.5 mm2) AWG = 14- weight 1.6 kg (3.53 lbs)
Auxiliary box is used for control equipment and heating elements.
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 41
2- one box as default - stator Pt-100 (6 pcs) - bearing Pt-100 (optional, variant code 107) - separate box for heating element (variant code 450/451) - Provision for vibration sensors (optional, variant code 654*) * The bigger auxiliary box is needed if the variant code 654 is
selected.
Specification:
Material designation Al-Si10Mg (pressure die cast)Material standard EN 573-3Surface treatment RAL 7001 (grey)
Other features:
- equipped with assembly rail ARH 22 (DIN-35)- main dimensions 230 mm x 330 mm x 180 mm (9.1”x12.99”x7.09”)- degree of protection IP 66 (IEC 529)- gasket material silicone- temperature resistance -55 - +100 °C - max. terminal blocks: 36 pcs 0.004 in2 (2.5 mm2) AWG = 14- weight 5.6 kg (12.3 lbs)
Bigger auxiliary box
42 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
Bearings The motors are normally fitted with single-row deep groove ball bearings as listed in the table below.
Axially-locked bearingsAll motors are equipped as standard with an axially-locked bearing at the D-end.
The bearing's outer ring is tightly locked between bearing's covers and the housing fit.
Transport locking
Motors with roller bearings are fitted with a transport lock to prevent damage to the bearings during transport. All high voltage motors are fitted with a warning sign when the transport lock is fitted to prevent operational damage and alert operators.
Locking may be fitted in other situations where the transport conditions are considered as potentially damaging.
Motor Number Deep groove ball bearingssize of poles D-end N-end
506AT 2 6316M/C3 6316M/C3
4-6 6319/C3 6316/C3
587 2 6316M/C3 6316M/C3
4-6 6322/C3 6316/C3
68_ 2 6317M/C3 6317M/C3
4-8 6324/C3 6319/C3
728 4-8 6326M/C3 6322/C3
Motor Number Roller bearings, variant code 037size of poles D-end
506AT 4-6 NU 319M/C3
587 4-6 NU 322M/C3
68_ 4-8 NU 324M/C3
728 4-8 NU 326M/C3
If the bearing at the D-end is replaced with a roller bearing (NU-), higher radial forces can be handled. Roller bearings are suitable for belt drive applications.
The N-end bearing is axially free and can take the thermal expansion. Note! NU-bearing is axially locked at N-end.
Basic version with deep groove ball bearings Version with roller bearings, variant code 037
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 43
2
Bearing seals
Axially locked (D-end)
All high voltage motors are equipped with labyrinth sealed bearings.
Axially free (N-end)
44 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
Lubrication intervalsThe lubrication interval is defined by following the L1-principle. This means that 99% of ABB's motors will achieve normal service intervals. Values for the lubrication intervals can also be calculated according to the L10-principle, which are normally doubled compared to L1-values. Values are available from ABB on request.
Lubrication
On delivery, the motors are pre-lubricated with high quality grease. The grease grade is stamped on the lubrication plate fastened to the motor frame. See page 33 for an example of a lubrication plate.
More information about lubrication and greases can be found in ABB's High Voltage Process Performance Manual delivered with the motor.
Motors with relubrication nipplesMotors are lubricated while running and the bearing system on all high voltage motors has been built so that a valve disc can be used for lubrication.
The grease outlet opening has closing valves at both ends that should be opened before greasing and closed 1-2 hours after regreasing. Closing the valves ensures that the construction is tight and prevents dust or dirt getting inside the bearing.
The table below gives lubrication intervals for different speeds (according to the L1-principle). The values are valid for horizontal mounted motors (B3), using the synthetic base oil mentioned in ABB's High Voltage Process Performance Motors Manual.
For more information, see ABB's High Voltage Process Performance Motors Manual.
Frame 3600 1800 <1200
size Ambient °C r/min r/min r/min
Ball bearings, horizontal motor: lubrication intervals in duty hours
506AT 25 3000 8800 8800
506AT 40 1500 5100 8800
587 25 3000 7300 8800
587 40 1500 3600 8000
68_ 25 2200 5900 8800
68_ 40 1100 3000 6600
728 25 2200 5900 8800
728 40 1100 3000 8800
Note! Special grease for roller bearings.
Frame 3600 1800 <1200
size Ambient °C r/min r/min r/min
Roller bearings: lubrication intervals in duty hours
506AT 25 - 4400 5900
506AT 40 - 2200 3000
587 25 - 3000 4400
587 40 - 1500 2200
68_ 25 - 2200 4400
68_ 40 - 1100 2200
728 25 - 2200 4400
728 40 - 1100 2200
Note! The lubrication intervals defined at SF 1.0.
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 45
2
Permissible axial forcesThe following tables give the permissible axial forces in Newton, assuming zero radial force. The values are based on normal conditions at 60 Hz with standard bearings and calculated bearing lives L10h 40,000 hours.
Given axial forces FAD, assumes D-bearing locked by means of locking ring.
SI units 40,000 hours2-pole 4-pole ≥ 6-pole
Motorsize
FAD
NFAZ
NFAD
NFAZ
NFAD
NFAZ
N
506 1850 3850 3800 5800 4600 6600
587 750 4550 3800 7600 5000 8800
68_ 100 5100 2480 8480 3340 9340
728 - 4600 2640 8640 3570 9570
FAD FAZ
Permissible radial forces Length of Ball bearings Roller bearingsshaft SI units Imperial units SI units Imperial units
Motor extension 40,000 hours 40,000 hourssize Poles E (mm) FX0 (N) FXmax(N) FX0 (lbs) FXmax(lbs) FX0 (N) FXmax(N) FX0 (lbf) FXmax(lbf)
506 2 140 4600 4100 1034 922 - - - -4 170 7550 6550 1697 1472 24600 9500 5530 21366 170 8450 7300 1900 1641 27600 9500 6205 2136
587 2 140 2050 1850 461 416 - - - -4 210 9200 7950 2068 1787 33300 12000 7486 26986 210 10700 9250 2405 2079 37750 12000 8487 2698
68_ 2 170 300 250 67 56 - - - -4 210 6770 5980 1522 1344 38100 15000 8565 3372≥ 6 210 9030 7960 2030 1789 42300 15000 9509 3372
728 4 210 7400 6570 1664 1477 50550 21000 11364 4721≥ 6 210 9440 8390 2122 1886 56850 21000 12780 4721
Mounting arrangement IM B3
Vibration limitsPoles Speed
rpmDesign Bearing housing
vibration
2 1800 < n 3600 Standard 0.1 in./s peak (2.54 mm/s)
≥4 1800 Standard 0.1 in./s peak (2.54 mm/s)
The following table lists the vibration values that the mo-tors fulfil in compliance with IEC 60034-14.
Imperial units 40,000 hours2-pole 4-pole ≥ 6-pole
Motorsize
FAD
lbfFAZ
lbfFAD
lbfFAZ
lbfFAD
lbfFAZ
lbf
506 416 865 854 1303 1034 1483
587 169 1022 854 1708 1124 1978
68_ 22 1146 557 1906 751 2099
728 - 1034 593 1942 802 2151
46 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
Ordering informationSample orderWhen placing an order, please state the following mini-mum data in the order, as in example.The product code of the motor is composed in accor-dance with the following example.
Explanation of the product code:Positions 1 to 4 3GBM, 3GGM = Totally enclosed fan cooled squirrel cage motor with cast iron frame, high voltage
Positions 5 and 6 NEMA-frame90 = 50_98 = 58_99 = 68_02 = 72_
Position 7 Speed (Pole pairs)1 = 2 poles 2 = 4 poles 3 = 6 poles 4 = 8 poles
Position 8 to 10 Serial number
Motor size
A B C D, E, F, G
M3BM 587LKA 3GBM 981 810 - A P A 003 etc.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
A Motor typeB Motor sizeC Product code D Mounting arrangement code E Voltage and frequency code F Generation codeG Variant codes
Position 11 - (dash)
Position 12 Mounting arrangementA = Foot mounted, terminal box on top (F0)H = Foot and flange mounting, D flange, terminal box on top (F0)
Position 13Voltage and frequency codeSee table below
Position 14 Generation codeA, B, C...
The product code must be, if needed, followed by variant codes.
Code letter for voltage and frequency
W60 Hz
4000 V
Motor type M3BM 587 LKAPole number 2Mounting arrangement (IM code) IM B3 (IM 1001) Rated output 250 HPProduct code GBM981810-APA Variant codes if needed
Code letters for supplementing the product code - single speed motors
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 47
2
Rating plate
Rating plate, HV motor
Lubrication plate
Lubrication plate, HV motor
48 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
Efficiency Power factor Current
Full 3/4 Full 3/4 FLA at KV LRA NLC
Output Motor type Product code Speed load load load load 4 (Y) 2.3 (D)
HP r/min r/min 100% 75% 100% 75% A A % Code A
NEMA HV Cast iron motors Technical data for totally enclosed squirrel cage three phase motors IP 55 – TEFC / IC 411 – Insulation class F, temperature rise class B, ambient temperature 40 °C, S.F. 1.15
The bullet in the product code indicates choice of mounting arrangement (see ordering information page).
1) 3600 r/min: 587LK, 688L: The given values of load inertia assume two starts from cold and one start from warm conditions in succession against quadratic load torque with 90% of the rated torque at the rated speed and at 80% of the rated voltage. 689LK: The given values of load inertia assume two starts from cold and one start from warm conditions in succession against quadratic load torque with 85% of the rated torque at the rated speed and at 80% of the rated voltage.
1800 r/min: 506AT LK, 587LK, 688L, 689LK: The given values of load inertia assume three starts from cold and two starts from warm conditions in succession against quadratic load torque with 90% of the rated torque at the rated speed and at 80% of the rated voltage. 728L: The given values of load inertia assume three starts from cold and two starts from warm conditions in succession against quadratic load torque with 85% of the rated torque at the rated speed and at 80% of the rated voltage.
1200 r/min and 900 r/min: The given values of load inertia assume three starts from cold and two starts from warm conditions in succession against
quadratic load torque with 90% of the rated torque at the rated speed and at 80% of the rated voltage.
Motors fulfil the starting requirements in NEMA MG 1, Part 20.2) Starting time with given values of the load inertia from cold condition in succession against quadratic load torque defined in footnote 1).3) The sound pressure levels are presented at no-load. The magnetic noise level of 2- and 4-pole motors is typically low compared to the fan noise, resulting no increase in the noise level on-load. Sound level values of 6...8-pole motors at on-load are typically 1...3 dB(A) higher than the corresponding values at no-load. The variation and measuring tolerance of the figures is +3 dB(A).4) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045.
4000 V (star) or 2.3 kV (delta) 60 Hz150 900 M3BM 688 LA 3GBM 893 93.7 93.2 0.76 0.70 23 40 540 G 11175 1200 M3BM 506AT LKB 3GBM 1192 94.0 93.6 0.76 0.70 26 46 650 H 14200 1800 M3BM 506AT LKA 3GBM 1788 94.0 93.7 0.85 0.82 27 47 660 G 9200 900 M3BM 688 LB 3GBM 892 94.0 93.7 0.76 0.70 30 53 550 G 15250 3600 4) M3BM 587 LKA 3GBM 3579 93.1 92.5 0.90 0.89 32 56 640 G 7250 1800 M3BM 506AT LKB 3GBM 1787 94.3 94.1 0.85 0.81 34 59 630 G 13250 1200 M3BM 587 LKA 3GBM 1191 94.6 94.5 0.79 0.74 36 63 560 G 16250 900 M3BM 688 LC 3GBM 892 94.1 93.8 0.75 0.69 38 66 570 G 19275 1800 M3BM 506AT LKC 3GBM 1786 94.5 94.3 0.85 0.81 37 65 630 G 14300 3600 4) M3BM 587 LKB 3GBM 3580 93.8 93.3 0.91 0.90 38 66 650 G 8300 1800 M3BM 587 LKA 3GBM 1790 94.1 93.7 0.82 0.79 42 72 610 G 16300 1200 M3BM 587 LKB 3GBM 1192 94.9 94.8 0.79 0.75 43 75 590 G 18300 900 M3BM 688 LD 3GBM 891 94.4 94.3 0.77 0.72 45 78 530 F 20350 3600 4) M3BM 587 LKC 3GBM 3579 94.2 93.8 0.91 0.90 44 77 650 G 9350 1800 M3BM 587 LKB 3GBM 1789 94.4 94.1 0.83 0.81 48 83 610 G 17350 1200 M3BM 587 LKC 3GBM 1191 95.0 95.1 0.80 0.76 50 86 560 F 20350 900 M3BM 688 LE 3GBM 891 94.7 94.6 0.77 0.71 52 90 560 G 24400 3600 4) M3BM 688 LA 3GBM 3581 94.3 93.9 0.89 0.88 51 89 650 G 12400 1800 M3BM 587 LKC 3GBM 1790 94.8 94.5 0.83 0.80 54 95 660 G 20400 1200 M3BM 587 LKD 3GBM 1192 95.3 95.3 0.80 0.76 57 98 620 G 23400 900 M3BM 689 LKA 3GBM 895 95.0 94.9 0.77 0.71 59 103 560 G 28450 3600 4) M3BM 688 LB 3GBM 3580 94.7 94.4 0.91 0.90 56 98 660 G 12450 1800 M3BM 587 LKD 3GBM 1789 95.0 94.9 0.86 0.84 60 103 630 G 18450 1200 M3BM 587 LKE 3GBM 1193 95.4 95.4 0.80 0.76 64 111 600 G 27450 1200 M3BM 688 LA 3GBM 1192 95.5 95.4 0.80 0.76 63 110 620 G 26450 900 M3BM 689 LKB 3GBM 895 95.2 95.0 0.76 0.71 67 116 590 G 33500 3600 4) M3BM 688 LC 3GBM 3579 94.8 94.7 0.91 0.90 63 109 650 G 12500 1800 M3BM 587 LKE 3GBM 1791 95.2 95.0 0.86 0.83 66 115 640 G 22500 1200 M3BM 688 LB 3GBM 1195 95.7 95.5 0.79 0.74 72 124 630 G 32500 900 M3BM 689 LKC 3GBM 895 95.2 95.0 0.76 0.71 74 129 590 G 37550 3600 4) M3BM 688 LD 3GBM 3579 95.1 95.0 0.91 0.91 68 119 650 G 12550 900 M3BM 689 LKD 3GBM 895 95.3 95.1 0.75 0.69 83 144 610 H 42600 1800 M3BM 688 LA 3GBM 1792 95.9 95.7 0.85 0.82 79 138 650 G 27600 1200 M3BM 689 LKA 3GBM 1195 95.9 95.8 0.79 0.74 86 149 630 G 38600 900 M3BM 728 LA 3GBM 895 95.5 95.4 0.80 0.77 84 147 550 F 34680 1200 M3BM 689 LKB 3GBM 1195 96.0 95.8 0.79 0.74 97 169 630 G 43700 1800 M3BM 689 LKA 3GBM 1791 96.0 95.9 0.85 0.83 92 160 630 G 31700 900 M3BM 728 LB 3GBM 895 95.6 95.4 0.79 0.75 99 172 590 G 42750 900 M3BM 728 LC 3GBM 896 95.7 95.5 0.80 0.75 106 184 610 G 45800 1800 M3BM 689 LKB 3GBM 1792 96.2 96.1 0.86 0.83 105 182 640 G 34800 1200 M3BM 728 LA 3GBM 1194 95.9 95.9 0.84 0.81 107 186 630 G 37900 1800 M3BM 728 LA 3GBM 1793 95.9 95.7 0.86 0.84 117 203 650 G 35900 1200 M3BM 728 LB 3GBM 1194 96.0 96.0 0.84 0.82 120 208 620 G 40950 1200 M3BM 728 LC 3GBM 1194 96.1 96.1 0.84 0.81 127 220 650 G 44
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 49
2
Torque Power Load Starting Maximum Sound
Rated LRT BDT factor inertia time stalling Rotor Rotor Motor pressure
Output Motor type 1) at start 1) cold 2) time hot inertia weight weight level 3)
HP r/min lb-ft % % cos ϕk lb-ft2 s s lb-ft2 lbs lbs dB(A)
NEMA HV Cast iron motorsTechnical data for totally enclosed squirrel cage three phase motors IP 55 – TEFC / IC 411 – Insulation class F, temperature rise class B, ambient temperature 40 °C, S.F. 1.15
4000 V (star) or 2.3 kV (delta) 60 Hz150 900 M3BM 688 LA 883 100 260 0.13 3455 11 22 232 1200 5600 80175 1200 M3BM 506AT LKB 772 130 300 0.16 1980 8 15 75.1 640 2950 70200 1800 M3BM 506AT LKA 588 170 270 0.20 831 6 20 54.1 570 3140 78200 900 M3BM 688 LB 1177 110 270 0.13 4507 10 22 243 1240 5740 80250 3600 4) M3BM 587 LKA 367 90 280 0.13 210 10 18 68.5 610 3960 82250 1800 M3BM 506AT LKB 735 100 280 0.14 1016 8 17 47.4 510 2920 78250 1200 M3BM 587 LKA 1103 130 230 0.17 2743 9 20 122 840 4140 76250 900 M3BM 688 LC 1472 110 280 0.14 5533 9 22 254 1290 5820 80275 1800 M3BM 506AT LKC 809 100 280 0.14 1107 8 16 49.8 530 2990 78300 3600 4) M3BM 587 LKB 440 100 280 0.13 246 9 16 79.7 680 4270 82300 1800 M3BM 587 LKA 881 110 240 0.15 1197 8 16 103 750 3940 80300 1200 M3BM 587 LKB 1323 140 240 0.17 3238 8 20 150 980 4540 76300 900 M3BM 688 LD 1769 100 250 0.13 6539 10 22 287 1420 6210 80350 3600 4) M3BM 587 LKC 514 100 270 0.13 281 8 14 83.4 700 4380 82350 1800 M3BM 587 LKB 1028 110 240 0.15 1373 8 16 116 820 4130 80350 1200 M3BM 587 LKC 1544 140 220 0.17 3722 8 20 164 1050 4740 76350 900 M3BM 688 LE 2063 110 270 0.13 7526 9 22 342 1630 6930 80400 3600 4) M3BM 688 LA 587 80 280 0.11 315 10 20 137 880 5170 83400 1800 M3BM 587 LKC 1174 130 250 0.15 1545 7 14 129 880 4350 80400 1200 M3BM 587 LKD 1764 160 240 0.17 4197 7 20 206 1270 5350 76400 900 M3BM 689 LKA 2349 120 230 0.16 8497 10 20 427 1770 6790 80450 3600 4) M3BM 688 LB 660 90 270 0.12 349 10 18 158 980 5570 83450 1800 M3BM 587 LKD 1322 120 230 0.14 1714 8 14 154 1010 4740 80450 1200 M3BM 587 LKE 1982 100 250 0.13 4664 9 20 210 1270 5380 76450 1200 M3BM 688 LA 1983 140 240 0.15 4665 7 20 280 1420 6340 80450 900 M3BM 689 LKB 2641 130 250 0.16 9453 9 20 491 1980 7300 80500 3600 4) M3BM 688 LC 734 90 270 0.12 381 9 16 164 1010 5650 83500 1800 M3BM 587 LKE 1467 100 270 0.13 1879 9 16 180 1120 5010 80500 1200 M3BM 688 LB 2198 120 280 0.13 5125 9 20 440 1780 6670 80500 900 M3BM 689 LKC 2935 130 250 0.17 10396 9 20 522 2090 7510 80550 3600 4) M3BM 688 LD 808 90 260 0.11 412 9 15 176 1070 5960 83550 900 M3BM 689 LKD 3228 140 260 0.16 11327 8 20 554 2190 7810 80600 1800 M3BM 688 LA 1759 100 290 0.11 2201 9 15 280 1400 6550 80600 1200 M3BM 689 LKA 2638 130 280 0.13 6025 9 20 507 2050 7540 80600 900 M3BM 728 LA 3522 100 220 0.13 12246 12 20 731 2380 9210 78680 1200 M3BM 689 LKB 2990 130 280 0.13 6727 8 22 510 2150 7760 80700 1800 M3BM 689 LKA 2053 100 270 0.12 2513 9 12 295 1500 6990 80700 900 M3BM 728 LB 4107 110 240 0.13 14053 10 20 835 2650 9830 78750 900 M3BM 728 LC 4400 110 250 0.13 14942 10 20 938 2920 10490 78800 1800 M3BM 689 LKB 2346 100 270 0.11 2815 8 12 354 1730 7760 80800 1200 M3BM 728 LA 3519 140 250 0.15 7755 7 20 780 2500 9530 82900 1800 M3BM 728 LA 2637 110 260 0.12 3108 8 20 627 2340 10300 83900 1200 M3BM 728 LB 3960 130 240 0.15 8590 8 20 832 2640 9850 82950 1200 M3BM 728 LC 4179 140 260 0.15 9000 7 20 883 2770 10230 82
50 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
Efficiency Power factor Current
Full 3/4 Full 3/4 FLA at KV LRA NLC
Output Motor type Product code Speed load load load load 4 (Y) 2.3 (D)
HP r/min r/min 100% 75% 100% 75% A A % Code A
NEMA Non-sparking and Dust Ignition Proof HV cast iron motors Technical data for totally enclosed squirrel cage three phase motors IP 55 – TEFC / IC 411 – Insulation class F, temperature rise class B, ambient temperature 40 °C, S.F. 1.15
The bullet in the product code indicates choice of mounting arrangement (see ordering information page).
1) 3600 r/min: 587LK, 688L: The given values of load inertia assume two starts from cold and one start from warm conditions in succession against quadratic load torque with 90% of the rated torque at the rated speed and at 80% of the rated voltage. 689LK: The given values of load inertia assume two starts from cold and one start from warm conditions in succession against quadratic load torque with 85% of the rated torque at the rated speed and at 80% of the rated voltage.
1800 r/min: 506AT LK, 587LK, 688L, 689LK: The given values of load inertia assume three starts from cold and two starts from warm conditions in succession against quadratic load torque with 90% of the rated torque at the rated speed and at 80% of the rated voltage. 728L: The given values of load inertia assume three starts from cold and two starts from warm conditions in succession against quadratic load torque with 85% of the rated torque at the rated speed and at 80% of the rated voltage.
1200 r/min and 900 r/min: The given values of load inertia assume three starts from cold and two starts from warm conditions in succession against
quadratic load torque with 90% of the rated torque at the rated speed and at 80% of the rated voltage.
Motors fulfil the starting requirements in NEMA MG 1, Part 20.2) Starting time with given values of the load inertia from cold condition in succession against quadratic load torque defined in footnote 1).3) The sound pressure levels are presented at no-load. The magnetic noise level of 2- and 4-pole motors is typically low compared to the fan noise, resulting no increase in the noise level on-load. Sound level values of 6...8-pole motors at on-load are typically 1...3 dB(A) higher than the corresponding values at no-load. The variation and measuring tolerance of the figures is +3 dB(A).4) Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045.
4000 V (star) or 2.3 kV (delta) 60 Hz150 900 M3GM 688 LA 3GGM 893 93.6 93.2 0.76 0.70 23 40 540 G 11175 1200 M3GM 506AT LKB 3GGM 1192 93.8 93.5 0.76 0.70 26 46 640 H 13200 1800 M3GM 506AT LKA 3GGM 1788 94.0 93.6 0.85 0.82 27 47 650 G 9200 900 M3GM 688 LB 3GGM 892 93.9 93.6 0.76 0.70 30 53 550 G 15250 3600 4) M3GM 587 LKA 3GGM 3579 93.0 92.4 0.90 0.89 32 56 630 G 7250 1800 M3GM 506AT LKB 3GGM 1787 94.2 94.0 0.85 0.81 34 59 620 G 13250 1200 M3GM 587 LKA 3GGM 1191 94.5 94.4 0.79 0.74 36 63 550 F 16250 900 M3GM 688 LC 3GGM 892 94.0 93.7 0.75 0.69 38 66 560 G 19275 1800 M3GM 506AT LKC 3GGM 1786 94.4 94.2 0.85 0.81 37 65 620 G 14300 3600 4) M3GM 587 LKB 3GGM 3580 93.7 93.3 0.91 0.90 38 66 640 G 8300 1800 M3GM 587 LKA 3GGM 1790 94.0 93.6 0.82 0.79 42 73 600 G 16300 1200 M3GM 587 LKB 3GGM 1192 94.8 94.7 0.79 0.75 43 75 580 G 18300 900 M3GM 688 LD 3GGM 891 94.3 94.2 0.77 0.72 45 78 530 F 20350 3600 4) M3GM 587 LKC 3GGM 3579 94.1 93.8 0.91 0.90 44 77 640 F 9350 1800 M3GM 587 LKB 3GGM 1789 94.3 94.1 0.83 0.81 48 83 600 G 17350 1200 M3GM 587 LKC 3GGM 1191 95.0 95.0 0.80 0.76 50 86 560 F 20350 900 M3GM 688 LE 3GGM 891 94.7 94.5 0.77 0.72 52 90 560 G 24400 3600 4) M3GM 688 LA 3GGM 3581 94.3 93.9 0.89 0.88 51 89 640 G 12400 1800 M3GM 587 LKC 3GGM 1790 94.7 94.5 0.83 0.80 55 95 650 G 20400 1200 M3GM 587 LKD 3GGM 1192 95.3 95.2 0.80 0.76 57 98 610 G 23400 900 M3GM 689 LKA 3GGM 895 94.9 94.8 0.77 0.72 59 103 550 G 28450 3600 4) M3GM 688 LB 3GGM 3580 94.7 94.4 0.90 0.90 57 98 640 F 12450 1800 M3GM 587 LKD 3GGM 1789 95.0 94.9 0.86 0.84 60 104 620 G 18450 1200 M3GM 587 LKE 3GGM 1193 95.3 95.3 0.80 0.76 64 111 600 G 27450 1200 M3GM 688 LA 3GGM 1192 95.4 95.3 0.80 0.76 63 110 610 G 26450 900 M3GM 689 LKB 3GGM 895 95.1 94.9 0.76 0.71 67 116 580 G 33480 3600 4) M3GM 688 LC 3GGM 3580 94.7 94.5 0.91 0.90 60 105 670 G 12490 900 M3GM 689 LKC 3GGM 895 95.1 94.9 0.76 0.70 73 127 600 G 36500 1800 M3GM 587 LKE 3GGM 1791 95.1 94.9 0.86 0.83 66 115 630 G 22500 1200 M3GM 688 LB 3GGM 1195 95.7 95.5 0.79 0.74 72 124 630 G 32530 3600 4) M3GM 688 LD 3GGM 3579 95.1 94.9 0.91 0.91 66 115 660 G 12540 900 M3GM 689 LKD 3GGM 895 95.3 95.0 0.75 0.69 81 141 620 H 42600 1800 M3GM 688 LA 3GGM 1792 95.9 95.7 0.85 0.82 79 138 640 G 27600 1200 M3GM 689 LKA 3GGM 1195 95.9 95.7 0.79 0.74 86 149 630 G 38600 900 M3GM 728 LA 3GGM 895 95.4 95.3 0.80 0.77 84 147 550 F 34670 1200 M3GM 689 LKB 3GGM 1195 95.9 95.8 0.79 0.74 96 166 630 G 43700 1800 M3GM 689 LKA 3GGM 1791 95.9 95.9 0.85 0.83 92 160 630 G 31700 900 M3GM 728 LB 3GGM 895 95.6 95.4 0.79 0.75 99 173 590 G 42750 900 M3GM 728 LC 3GGM 896 95.7 95.5 0.80 0.75 106 184 600 G 45780 1800 M3GM 689 LKB 3GGM 1792 96.1 96.0 0.85 0.83 102 178 650 G 34800 1200 M3GM 728 LA 3GGM 1194 95.9 95.8 0.84 0.81 107 186 630 G 37870 1200 M3GM 728 LB 3GGM 1194 96.0 95.9 0.84 0.81 116 202 630 G 40880 1800 M3GM 728 LA 3GGM 1793 95.9 95.6 0.86 0.84 115 199 660 G 35950 1200 M3GM 728 LC 3GGM 1194 96.1 96.1 0.84 0.81 127 220 640 G 44
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 51
2
Torque Power Load Starting Maximum Sound
Rated LRT BDT factor inertia time stalling Rotor Rotor Motor pressure
Output Motor type 1) at start 1) cold 2) time hot inertia weight weight level 3)
HP r/min lb-ft % % cos ϕk lb-ft2 s s lb-ft2 lbs lbs dB(A)
NEMA Non-sparking and Dust Ignition Proof HV cast iron motorsTechnical data for totally enclosed squirrel cage three phase motors IP 55 – TEFC / IC 411 – Insulation class F, temperature rise class B, ambient temperature 40 °C, S.F. 1.15
1) When ordering, the following variant codes have to be added to the product code acc. to needs. for non-sparking motors: 807 CSA design, Class I, Div 2 Group A, B, C, D T3 809 CSA design, Class I, Zone 2 AEx nA IIC T3 and Ex nA II T3 for DIP motors: 810 CSA design, Class II, Div 2 Group F, G and Class III
4000 V (star) or 2.3 kV (delta) 60 Hz150 900 M3GM 688 LA 883 100 260 0.14 3455 11 22 232 1200 5590 80175 1200 M3GM 506AT LKB 772 130 300 0.16 5125 8 15 75.1 640 2940 70200 1800 M3GM 506AT LKA 588 170 260 0.20 831 6 20 54.1 570 3140 78200 900 M3GM 688 LB 1177 110 270 0.13 4507 10 22 243 1240 5730 80250 3600 4) M3GM 587 LKA 367 90 270 0.13 210 10 18 68.5 610 3960 82250 1800 M3GM 506AT LKB 735 100 280 0.14 1016 8 17 47.4 510 2910 78250 1200 M3GM 587 LKA 1103 130 230 0.18 2743 9 20 122 840 4140 76250 900 M3GM 688 LC 1472 110 270 0.14 5533 9 22 254 1290 5810 80275 1800 M3GM 506AT LKC 809 100 270 0.14 1107 8 16 49.8 530 2990 78300 3600 4) M3GM 587 LKB 440 100 270 0.13 246 9 16 79.7 680 4270 82300 1800 M3GM 587 LKA 881 110 240 0.15 1197 9 16 103 750 3940 80300 1200 M3GM 587 LKB 1323 140 230 0.18 3238 8 20 150 980 4530 76300 900 M3GM 688 LD 1769 100 250 0.14 6539 10 22 287 1420 6200 80350 3600 4) M3GM 587 LKC 514 100 270 0.13 281 9 14 83.4 700 4370 82350 1800 M3GM 587 LKB 1028 110 240 0.15 1373 8 16 116 820 4120 80350 1200 M3GM 587 LKC 1544 140 220 0.17 3722 8 20 164 1050 4730 76350 900 M3GM 688 LE 2063 110 260 0.13 7526 9 22 342 1630 6910 80400 3600 4) M3GM 688 LA 587 80 270 0.11 315 11 20 137 880 5160 83400 1800 M3GM 587 LKC 1174 120 250 0.15 1545 7 14 129 880 4340 80400 1200 M3GM 587 LKD 1764 150 240 0.17 4197 7 20 206 1270 5340 76400 900 M3GM 689 LKA 2349 120 230 0.17 8497 10 20 427 1770 6770 80450 3600 4) M3GM 688 LB 660 90 270 0.12 349 10 18 158 980 5560 83450 1800 M3GM 587 LKD 1322 110 230 0.14 1714 8 14 154 1010 4730 80450 1200 M3GM 587 LKE 1982 100 250 0.13 4664 9 20 210 1270 5360 76450 1200 M3GM 688 LA 1983 140 240 0.15 4665 8 20 280 1420 6330 80450 900 M3GM 689 LKB 2641 130 240 0.17 9453 10 20 491 1980 7280 80480 3600 4) M3GM 688 LC 704 90 270 0.12 368 9 13 140 1010 5650 83490 900 M3GM 689 LKC 2876 130 250 0.17 10209 9 22 490 2090 7500 80500 1800 M3GM 587 LKE 1467 100 270 0.13 1879 9 16 180 1120 5000 80500 1200 M3GM 688 LB 2198 120 280 0.13 5125 9 20 440 1780 6660 80530 3600 4) M3GM 688 LD 778 90 270 0.11 400 9 12 150 1080 5960 83540 900 M3GM 689 LKD 3169 140 270 0.16 11142 8 22 520 2200 7790 80600 1800 M3GM 688 LA 1759 100 280 0.11 1879 9 15 280 1400 6540 80600 1200 M3GM 689 LKA 2638 130 280 0.13 6025 9 20 507 2050 7530 80600 900 M3GM 728 LA 3522 100 220 0.13 12246 12 20 731 2380 9190 78670 1200 M3GM 689 LKB 2946 130 280 0.13 6640 8 22 510 2150 7740 80700 1800 M3GM 689 LKA 2053 100 270 0.12 2513 9 12 295 1500 6980 80700 900 M3GM 728 LB 4107 110 240 0.13 14053 10 20 835 2650 9810 78750 900 M3GM 728 LC 4400 110 250 0.13 14942 10 20 938 2920 10470 78780 1800 M3GM 689 LKB 2287 100 280 0.11 2755 8 12 354 1730 7750 80800 1200 M3GM 728 LA 3519 130 250 0.15 7755 7 20 780 2500 9510 82870 1200 M3GM 728 LB 3827 140 250 0.15 8341 7 21 770 2640 9840 82880 1800 M3GM 728 LA 2579 110 270 0.12 3050 8 22 570 2350 10290 83950 1200 M3GM 728 LC 4179 140 250 0.15 9000 7 20 883 2770 10210 82
52 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
NEMA HV Cast iron motors - Variant codes Code Variant Motor size 1) 506AT 587 68_ 728
Balancing423 Balanced without key P P P P
424 Full key balancing. P P P P
Bearings and lubrication036 Transport lock for bearings. P P P P
037 Roller bearing at D-end. P P P P
107 PT100 2-wire in bearings. P P P P
654 Provision for vibration sensors (M8x1) P P P P
Branch standard designs178 Stainless steel/acid proof bolts. P P P P
398 Motor designed for ambient temperature -20°C to -40°C P P P P
Cooling system044 Unidirectional fan, clockwise seen from D-end. NA P P P
045 Unidirectional fan, counter clockwise seen from D-end. NA P P P
068 Metal fan. P P P P
Coupling035 Assembly of customer supplied coupling-half. P P P P
Drain holes065 Plugged existing drain holes. P P P P
448 Draining holes with metal plugs. P P P P
Hazardous environmentsMotor type M3GM.
807 CSA design, Class I, Div 2 Group A, B, C, D T3 P P P P
809 CSA design, Class I, Zone 2 AEx nA IIC T3 and Ex nA II T3 P P P P
810 CSA design, Class II, Div 2 Group F, G and Class III P P P P
Heating elements450 Heating element, 100-120 V. P P P P
451 Heating element, 200-240 V. P P P P
Painting114 Special paint colour, standard grade. P P P P
Protection158 Degree of protection IP 65. P P P P
403 Degree of protection IP 56. P P P P
Rating & instruction plates002 Restamping voltage, frequency and output, continuous duty. P P P P
Standards and regulations010 Fulfilling CSA Safety Certificate. S S S S
1) Certain variant codes cannot be used simultaneously. P = New manufacture only. NA = Not applicable. S = Included as standard.
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 53
2
Code Variant Motor size 1) 506AT 587 68_ 728
Terminal box019 Larger than standard terminal box. P P P P
021 Terminal box LHS (seen from D-end). P P P P
447 Top mounted separate terminal box for monitoring equipment. P P P P
656 No terminal box, six (6) leads out 1.5 m (5 ft) P P P P
750 Star point terminal box. P P P P
Testing146 Type test with report for motor from specific delivery patch. P P P P
147 Type test with report for motor from specific delivery patch, customer witnessed. P P P P
762 Noise level test. P P P P
Variable speed drives701 Insulated bearing at N-end P P P P
Foundation and installationFoundation studs P P P P
Sole plates without anchor bolts. P P P P
Sole plates with anchor bolts. P P P P
Slide rails for belt drives. P P P P
1) Certain variant codes cannot be used simultaneously. P = New manufacture only. NA = Not applicable. S = Included as standard.
54 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
NEMA HV Cast iron motors Sizes 506AT-728Dimension drawingsType I, Foot-mounted motors, IM B3 (IM 1001)
Motor Poles 2E 2F 2F' 2F'' BA U N-W F D FP O C A B J
size
506AT 2 20 20 22 28 8.5 2.5 5.5 0.625 12.5 47.9 38.2 58.7 23.2 33.5 3.2506AT 4-6 20 20 22 28 8.5 3.5 6.5 0.875* 12.5 47.9 38.2 59.7 23.2 33.5 3.2587 2 23 25 28 36 10 2.75 5.5 0.625 14.5 53.4 41.9 69.4 27.6 42.4 4.7587 4-6 23 25 28 36 10 4 8.25 1* 14.5 53.4 41.9 72.2 27.6 42.4 4.7688 2 27 - 32 36 11.5 3.125 6.5 0.75 17 53.4 46.1 72.7 33.1 45.5 5.9688 4-8 27 - 32 36 11.5 4.375 8.25 1* 17 53.4 46.1 74.4 33.1 45.5 5.9689 2 27 40 - - 11.5 3.125 6.5 0.75 17 53.4 46.1 79 33.1 51.8 5.9689 4-8 27 40 - - 11.5 4.375 8.25 1* 17 53.4 46.1 80.7 33.1 51.8 5.9728 4-8 32 36 - - 16 4.375 8.25 1* 18 56.9 51.7 86.1 37.4 55.9 6.3
Motor Poles G P K H R AB OE BSX FDX CX
size
506AT 2 1.7 25.7 13.2 1.26 2.148 32.7 14.4 14 41.5 4.5
506AT 4-6 1.7 25.7 13.2 1.26 3.007 32.7 14.4 15 42.5 4.5
587 2 2.3 29.4 17.6 1.38 2.402 35.5 18.1 15.7 51.5 9.8
587 4-6 2.3 29.4 17.6 1.38 3.436 35.5 18.1 18.4 54.3 5.1
688 2 3 32.8 16.2 1.38 2.704 35.5 22.2 17.8 53.3 11.8
688 4-8 3 32.8 16.2 1.38 3.817 35.5 22.2 19.6 55 7.9
689 2 1 32.8 16.2 1.38 2.704 35.5 22.2 18.6 59.6 11.8
689 4-8 3 32.8 16.2 1.38 3.817 35.5 22.2 20.4 61.3 7.9
728 4-8 3.5 37 17.7 1.65 3.817 37 27.8 20.7 64.9 7.9
Tolerances:
U +0 -0.001 F * +0 -0.003
F +0 - 0.0025 D +0 -0.06
Above table gives the main dimensions in inches.
For detailed drawings please see our web-pages 'www.abb.com/motors&generators' or contact us.
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 55
2
NEMA HV Cast iron motors Sizes 506AT-728Dimension drawingsType II, Foot-mounted motors, IM B3 (IM 1001)
Motor Poles 2E 2F 2F' 2F'' BA U N-W F D FP O C A B J
size
506AT 2 20 20 22 28 8.5 2.5 5.5 0.625 12.5 48.8 51.3 58.7 23.2 33.5 3.2506AT 4-6 20 20 22 28 8.5 3.5 6.5 0.875* 12.5 48.8 51.3 59.7 23.2 33.5 3.2587 2 23 25 28 36 10 2.75 5.5 0.625 14.5 54.2 55 69.4 27.6 42.4 4.7587 4-6 23 25 28 36 10 4 8.25 1* 14.5 54.2 55 72.2 27.6 42.4 4.7688 2 27 - 32 36 11.5 3.125 6.5 0.75 17 54.2 59.1 72.7 33.1 45.5 5.9688 4-8 27 - 32 36 11.5 4.375 8.25 1* 17 54.2 59.1 74.4 33.1 45.5 5.9689 2 27 40 - - 11.5 3.125 6.5 0.75 17 54.2 59.1 79 33.1 51.8 5.9689 4-8 27 40 - - 11.5 4.375 8.25 1* 17 54.2 59.1 80.7 33.1 51.8 5.9728 4-8 32 36 - - 16 4.375 8.25 1* 18 57.7 64.7 86.1 37.4 55.9 6.3
Motor Poles G P K H R AB OE BSX FDX CX
size
506AT 2 1.7 25.7 13.2 1.26 2.148 33.6 11.8 14 41.5 4.5
506AT 4-6 1.7 25.7 13.2 1.26 3.007 33.6 11.8 15 42.5 4.5
587 2 2.3 29.4 17.6 1.38 2.402 36.3 15.4 15.7 51.5 9.8
587 4-6 2.3 29.4 17.6 1.38 3.436 36.3 15.4 18.4 54.3 5.1
688 2 3 32.8 15.8 1.38 2.704 36.3 19.6 17.8 53.3 11.8
688 4-8 3 32.8 15.8 1.38 3.817 36.3 19.6 19.6 55 7.9
689 2 1 32.8 16.2 1.38 2.704 36.3 19.6 18.6 59.6 11.8
689 4-8 3 32.8 16.2 1.38 3.817 36.3 19.6 20.4 61.3 7.9
728 4-8 3.5 37 17.7 1.65 3.817 37.6 25.2 20.7 64.9 7.9
Tolerances:
U +0 -0.001 F * +0 -0.003
F +0 - 0.0025 D +0 -0.06
Above table gives the main dimensions in inches.
For detailed drawings please see our web-pages 'www.abb.com/motors&generators' or contact us.
56 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
NEMA HV Cast iron motors Sizes 506AT-728Dimension drawingsType I, Foot- and flange-mounted motors, IM B35 (IM 2001)
Motor Poles 2E 2F 2F' 2F'' BA U N-W F D FP O C A B J G
size
506AT 2 20 20 22 28 8.5 2.5 5.5 0.625 12.5 47.9 38.2 58.7 23.2 33.5 3.2 1.7506AT 4-6 20 20 22 28 8.5 3.5 6.5 0.875* 12.5 47.9 38.2 59.7 23.2 33.5 3.2 1.7587 2 23 25 28 36 10 2.75 5.5 0.625 14.5 53.4 41.9 69.4 27.6 42.4 4.7 2.3587 4-6 23 25 28 36 10 4 8.25 1* 14.5 53.4 41.9 72.2 27.6 42.4 4.7 2.3688 2 27 - 32 36 11.5 3.125 6.5 0.75 17 53.4 46.1 72.7 33.1 45.5 5.9 3688 4-8 27 - 32 36 11.5 4.375 8.25 1* 17 53.4 46.1 74.4 33.1 45.5 5.9 3689 2 27 40 - - 11.5 3.125 6.5 0.75 17 53.4 46.1 79 33.1 51.8 5.9 1689 4-8 27 40 - - 11.5 4.375 8.25 1* 17 53.4 46.1 80.7 33.1 51.8 5.9 3728 4-8 32 36 - - 16 4.375 8.25 1* 18 56.9 51.7 86.1 37.4 55.9 6.3 3.5
Motor Poles P K H R AB OE BSX FDX CX BE CB AJ AK BD BF BB
size
506AT 2 25.7 13.2 1.26 2.148 32.7 14.4 14 41.5 4.5 0.98 53.2 23.6 21.654 26 0.91 0.24
506AT 4-6 25.7 13.2 1.26 3.007 32.7 14.4 15 42.5 4.5 0.98 53.2 23.6 21.654 26 0.91 0.24
587 2 29.4 17.6 1.38 2.402 35.5 18.1 15.7 51.5 5.1 0.98 64.0 29.1 26.772 31.5 0.91 0.24
587 4-6 29.4 17.6 1.38 3.436 35.5 18.1 18.4 54.3 5.1 0.98 64.0 29.1 26.772 31.5 0.91 0.24
688 2 32.8 15.8 1.38 2.704 35.5 22.2 17.8 53.3 11.8 1.02 66.2 37 34.646 39.37 1.1 0.24
688 4-8 32.8 15.8 1.38 3.817 35.5 22.2 19.6 55 5.9 1.02 66.2 37 34.646 39.37 1.1 0.24
689 2 32.8 16.2 1.38 2.704 35.5 22.2 18.6 59.6 11.8 1.02 72.5 37 34.646 39.37 1.1 0.24
689 4-8 32.8 16.2 1.38 3.817 35.5 22.2 20.4 61.3 7.9 1.02 72.5 37 34.646 39.37 1.1 0.24
728 4-8 37 17.7 1.65 3.817 37 27.8 20.7 64.9 7.9 1.3 77.9 42.52 39.37 45.3 1.1 0.24
Tolerances:
U +0 -0.001 F * +0 -0.003
F +0 - 0.0025 D +0 -0.06
Above table gives the main dimensions in inches.
For detailed drawings please see our web-pages 'www.abb.com/motors&generators' or contact us.
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 57
2
Accessories
Provision for vibration sensors
Y
Z
X
Provision for vibration sensors M8x1. XYZ-directions. Available only for D-end.
58 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
NEMA HV cast iron motor construction
Typical exploded view of high voltage cast iron motor
1 Stator frame 2 End shield, D-end 3 Screws for end shield, D-end 4 End shield, N-end 5 Screws for end shield, N-end 6 Rotor with shaft 7 Key, D-end 8 Main terminal box 9 Middle box 10 Screws for terminal box cover 11 Outer bearing cover, D-end 12 Valve disc with labyrinth seal, D-end 13 Bearing, D-end 14 Inner bearing cover 15 Screws for bearing cover, D-end 16 Outer bearing cover, N-end
17 Valve disc with labyrinth seal, N-end 18 Bearing, N-end 19 Inner bearing cover, N-end 20 Spring 21 Screws for bearing cover, N-end 22 Fan 23 Fan cover 24 Screws for fan cover 25 Rating plate 26 Lubrication plate 27 Auxiliary terminal box 28 Grease nipple, D-end 29 Grease nipple, N-end 30 SPM nipple, D-end 31 SPM nipple, N-end 32 Additional identification plate
ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009 59
2
NEMA HV cast iron motors in brief, basic design
Motor size 506AT 587 68_ 728
Stator MaterialPaint colour shade
Paint thickness
Cast iron EN-GJL-250 EN 1561Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Two-pack epoxy paint, thickness ≥ 180 μm
Bearing end shields MaterialPaint colour shade
Paint thickness
Cast iron EN-GJL-200 SFS-EN 1561Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Two-pack epoxy paint, thickness ≥ 180 μm
Bearings D-end
N-end
2 pole4-8 pole
2 pole4-8 pole
6316M/C3 6319/C3
6316M/C3 6316/C3
6316M/C36322/C3
6316M/C36316/C3
6317M/C36324/C3
6317M/C36319/C3
–6326M/C3
–6322/C3
Axially-lockedbearings
Inner bearing cover As standard, locked at D-end
Bearing seal As standard, labyrinth seal in both ends.
Lubrication Regreasable bearingsRegreasing nipples M10x1 DIN 71412 A
SPM-nipples As standard
Rating and lubrication plate
Material Stainless steel, EN 10088, thickness 0.5 mm (0.02 ").
Terminal box Frame materialCover materialCover screws material
Structural steel S235JRG2-EN-10025, thickness 3 mm (0.12").Structural steel S235JRG2-EN-10025, thickness 3 mm (0.12").Blue passivated.
Connections Cable entriesTerminals
Blind gland plate.3 terminals for connection with cable lugs (not included) Grounding locations on frame and terminal box (in- and outside)
Fan Material Glass reinforced polypropylene, aluminum, steel or glass reinforced polyamide fan with metal hub. Direction of rotation / fans (IC411)- glass reinforced polypropylene bidirectional- aluminum birectional- steel bidirectional- glass reinforced polyamide fan unidirectional.
Fan cover MaterialPaint colour shade
SteelBlue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy polyester powder, thickness ≥ 80 μm
Stator winding MaterialInsulation
Winding protection
Form wound copper, VPIInsulation class F
PT100, 6 pieces
Rotor winding Material Pressure die-cast aluminum
Balancing method Half key balancing as standard
Key ways Open key way
Heating elements M3BM: On request 1x200 W 1x200 W 1x300 W 1x400 W
M3GM: As standard 2x80 W 2x80 W 2x80 W 2x80 W
Drain holes Standard, open on delivery.
Enclosure IP 55, higher protection as option.
Cooling method TEFC / IC 411
60 ABB /BU Machines/NEMA catalogue/Standard motors M3BM/GM EN 02-2009
2
Engineered NEMA Motors, Modular induction and cast iron motorsSquirrel cage three phase high voltage motors, Up to 4500 HP
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 61
3
62 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Contents PageGeneral information 63
Enclosure and cooling 65
Bearings 67
Vibration limits 72
Frame sizes 73
Notes 74
Technical data 75 Technical data, modular induction motors, engineered 75 Technical data, HV cast iron motors, engineered 97 Dimension drawings, HV modular induction motors, engineered, WPII 93 Dimension drawings, HV modular induction motors, engineered, TEAAC 95 Dimension drawings, HV modular induction motors, engineered, TEWAC 97 Dimension drawings, HV modular induction motors, engineered, WPII, vertical 99 Dimension drawings, HV modular induction motors, engineered, TEAAC, vertical 100 Dimension drawings, HV modular induction motors, engineered, TEWAC, vertical 101 Dimension drawings, HV cast iron motors, engineered, TEFC, F1 102 Dimension drawings, HV cast iron motors, engineered, TEFC, F2 104 Dimension drawings, HV cast iron motors, engineered, TEFC, F1, flange mouting 106 Dimension drawings, HV cast iron motors, engineered, TEFC, F2, flange mouting 107 Dimension drawings, HV cast iron motors, engineered, TEFC, vertical 108 NEMA type II terminal box (normal size) 109 NEMA type II terminal box (over size) 110
ABB reserves the right to change the design, technical specification and dimensions without prior notice.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 63
3
General informationABB's engineered motors are tailor-made to meet its customers' needs. This description contains information on ABB’s squirrel cage induction motors 60 Hz, with synchronous speed from 720 to 3600 rpm. The output range is from 150 HP to 4500 HP.
There are two different motor type described in this book. AMA modular induction motor features a welded steel frame. They are available with following cooling methods WPII, TEAAC and TEWAC. HXR features a rugged cast iron frame. They are totally enclosed fan cooled, TEFC.
AMA motors can be used for both standard and special applications. They can also be operated on adjustable speed drives or used as induction generators. The
mounting can be horizontal or vertical and the standard shaft heights are 400 to 500 mm (NEMA frames 68xx to 80xx).
HXR cast iron motors can be used for both standard and special applications. They can also be operated on adjustable speed drives or used as induction generators. The mounting can be horizontal or vertical and the standard shaft heights are from 355 to 560 mm (NEMA frames 58xx to 88xx). The largest frame 560 mm (88xx) is for horizontal mounting only.
All motors are manufactured for output power, voltage ranges and pole numbers indicated in table below.
Output (HP) at 60 Hz Output (HP) at 60 HzHXR AMA
Poles 2.3 kV 4 kV 4 kV
2 150 - 1750 150 - 1500 1000 - 3500 4 150 - 3000 150 - 3000 1000 - 45006 150 - 3000 150 - 3000 700 - 35008 200 - 2500 200 - 2250 450 - 250010 200 - 2000 250 - 2000 350 - 175012 200 - 1750 200 - 1500 200 - 1250
Output ranges of ABB NEMA motors (Temperature rise class B, insulation class F). Other voltages on request.
Mounting arrangement
Standard mounting arrangements for AMA motors. Other mountings on request.
Code I: IM B3Code II: IM 1001
Horizontal foot mounted
Code I: IM V1Code II: IM 4011
Vertical flange mounted (free shaft end facing downwards)
64 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Standard mounting arrangements for HXR motors
Code I: IM B3Code II: IM 1001
Standard floor mounting, feet facing downwards (Horizontal foot mounted)
Code I: IM V1Code II: IM 3011
Flange and free shaft end facing downwards (Vertical solid shaft, flange mounted)
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 65
3
Enclosure and coolingStandard combinations used for AMA motors are:
WPII (IP24W)
This weather-protected motor has a shaft-mounted cooling fan located inside the housing. The designof the motor reduces the ingress of rain, snow and airborne particles into the electrical parts. On the air intake path this is achieved by ensuring that the average velocity does not exceed 3 m/s, allowing any heavier particles to settle. The design of air intake path includes three acute changes in excess of 90 degrees to further reduce the flow rate to optimum level. The motor is protected against splashing water from any direction.
TEAAC (IP55)
In this design the fully enclosed motor has an air-to-air heat exchanger mounted on the motor. Shaft mounted fans are fitted both inside and outside of the casing to supply the inside and outside cooling circuits respectively. The motor is protected against dust and splashing water from any direction.
TEWAC (IP55)
This fully enclosed motor is fitted with an air-to-water heat exchanger. A shaft mounted fan is fitted inside the casing to supply the internal cooling circuit. Motor is protected against dust and splashing water from any direction.
The terminal boxes have a protection of at least IP55.
66 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Standard designs for AMA motors are:
- Weather-protected Machine TYPE II (WPII) acc. to NEMA MG1 - 1.25.8.2. The corresponding AMA design acc. to IEC 34 is IC01 IPW24.- Totally-enclosed water-air-cooled motor (TEWAC) acc. to NEMA MG1 - 1.26.8. The corresponding AMA design acc. to IEC 34 is IC81W IP55.- Totally-enclosed air-to-air-cooled motor (TEAAC) acc. to NEMA MG1 - 1.26.9. The corresponding AMA design acc. to IEC 34 is IC611 IP55.
Available as option:
- Washable reusable filters for the weather-protected motor IC01 IP23/IPW24. The filter material is normally stainless steel.- Motor with long connecting cables without main terminal box.
TEFC (IP55) HXR motor
The HXR motor has an external shaft mounted fan that use the surrounding air for cooling. The motor is protected
against dust and water jets. The principle of this motor is shown in below:
Sectional drawing of TEFC / IP55 motor.
Protection definition IP55
Dust-protected motor: In dust-protected motor, some dust can ingress the motor but it does not enter in sufficient quantity to interfere with the motor's operation.
The motor protected against water jets: Water projected by a nozzle against the motor from any direction shall have no harmful effect.
Method of Cooling (TEFC)
Frame surface cooled: The primary coolant is circulated in a closed circuit in the motor and gives its heat through the external surface of the motor (in addition to the heat transfer via the stator core and other heat conducting parts) to the final coolant which is the surrounding medium. The surface may be plain or ribbed, with or without an outer shell to improve the heat transfer.
Self circulation: The coolant is moved dependent on the rotational speed of the main motor either by action of the rotor alone or by means of a component designed for this purpose and mounted directly on the rotor of the main motor, or by a fan or pump unit mechanically driven by the rotor or the main motor.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 67
3
BearingsHorizontal motorsHorizontal motors 355 - 500 have deep groove ball bearings in both ends. HXR 560 has a double bearing arrangement (deep groove ball bearing and a cylindrical roller bearing) at D-end and cylindrical roller bearing at N-end (only horizontal motor available).
The bearing in D-end is axially locked in horizontal motors. Standard bearings of horizontal motors are stated
in table below and the bearing construction is shown in the figures on page 54.
The standard bearing solution is designed to carry the weight of the typical coupling half and the weight of the motor rotor only. Any additional radial or axial force caused by driven equipment may need the bearings to be specially constructed.
Table below: Standard bearings for horizontal motors.
Frame size Poles D-end N-end
HXR 355 2 6317M/C3 6317M/C3
HXR 355 ≥ 4 6322/C3 6319/C3
HXR 400 2 6317M/C3 6317M/C3
HXR 400 ≥ 4 6324/C3 6319/C3
HXR 450 2 6317M/C3 6317M/C3
HXR 450 ≥ 4 6324/C3 6322/C3
HXR 500 2 6319M/C3 6319M/C3
HXR 500 ≥ 4 6326/C3 6324/C3
HXR 560 ≥ 4 6034/C3 + NU1034/C3 NU322/C3
HXR 560 2 sleeve* sleeve*
AMA 400 2 6319M/C3 6319M/C3
AMA 400 ≥ 4 6324/C3 6319/C3
AMA 450 2 6319M/C3 6319M/C3
AMA 450 ≥ 4 6326/C3 6322/C3
AMA 500 ≥ 4 6330/C3 6324/C3
AMA 500 2 sleeve* sleeve*
* See section sleeve bearings.
68 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
D-end, axially locked N-end, axially free
1 Groove ball bearing 2 Inner bearing cover 3 Grease valve 4 Outer bearing cover5 Circlip 6 Hexagon screw 7 Spring 8 O-ring
Figure below: Standard bearing construction for horizontally mounted motors, frame sizes 355-500.
Figure below: Standard bearing construction for horizontally mounted motors HXR 560.
D-end, axially locked N-end, axially free
1 Inner bearing cover 2 Cylindrical roller bearing 3 Grease valve 4 Outer bearing cover5 Deep groove ball bearing 6 Outer bearing cover lid 7 Labyrinth seal 8 Grub screw
1 Cylindrical roller bearing 2 Inner bearing cover 3 Grease valve 4 Outer bearing cover5 Circlip 6 Hexagon screw
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 69
3
Bearing rating life
Most motors with standard bearings have a rated life time L10h in excess of 100000 h. Rated life time for frame 500, 2-pole, may be less than 100000h. The life times are calculated in accordance with ISO R 281-1.
The basic rated life L10h is the number of hours at rated bearing load and speed that 90% of a group of identical bearings will complete or exceed before the first evidence of failure.
Lubrication intervals
The motors are equipped with greasing nipple(s) in both ends for lubricating the bearings. The greasing nipples are located on top of the motor. The amount of grease and
the interval of greasing are stamped on the relubrication plate. The values are also shown in the table below.
Bearing type
Amount of grease [g]
Lubrication intervals in running hours at different speeds [rpm]
3600 3000 1800 - 1500 1200 - 1000 900 - 750 600 - 500
6317 35 800 2200 8800 8800 8800 8800
6319 45 400 1600 6600 8800 8800 8800
6322 60 6600 8800 8800 8800
6324 70 4400 8800 8800 8800
6326 80 4400 8800 8800 8800
6034 55 1600 3300 6600 8800
NU1034 55 1600 3300 4400 8800
NU322 60 3300 4400 4400 8800
7317 35 1100 4400 4400 4400 6600
7319 45 800 3300 4400 4400 6600
7322 60 3300 4400 4400 6600
7324 70 2200 4400 4400 6600
NB: Ball bearings on vertical motors should be lubricated twice as frequently as horizontal motors. The motor type is indicated by the first letter of the bearing type (6).
Table below: Relubrication intervals and grease amount.
70 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Sleeve bearings
The axial float of rotor is as standard ±8 mm from mechanical center. The running center locates within the float area and therefore operation is also allowed while machine is uncoupled, e.g. during test run. A pointer showing running center with regard to end limits is available as standard. Continuous axial forces are not permitted and therefore limiting type coupling is needed to ensure rotor location within axial float range. On request, when special axial float is at least ±3 mm, magnetic running center can be adjusted within ±2.4 mm from mechanical center (option).
Sleeve bearings are generally self-cooled, oil ring lubricated but some require external flood lubrication. Please see the lubrication table below for standard lubrication requirements based on a maximum 40 °C ambient and 50 Hz operation. Consult ABB for ambient temperatures above 40 °C, and/or for self-cooling of bearings where flood lubrication is standard. Those units requiring flood lubrication are supplied with provisions only. Refer oil supply pressure, type of oil, and location of provisions to factory for review prior to order acceptance.
Frame size Poles D-end bearing N-end bearing Lubrication Method
HXR 355 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)
HXR 355 ≥ 4 EFZLB 9-90 EFZLQ 9-90 Self lubrication
HXR 400 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)
HXR 400 ≥ 4 EFZLB 9-100 EFZLQ 9-100 Self lubrication
HXR 450 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)
HXR 450 4 EFZLB 9-100 EFZLQ 9-100 Oil circulation 1)
HXR 450 ≥ 6 EFZLB 9-100 EFZLQ 9-100 Self lubrication
HXR 500 2 EFZLB 9-90 EFZLQ 9-90 Oil circulation 1)
HXR 500 4 EFZLB 11-100 EFZLQ 9-100 Oil circulation 1)
HXR 500 ≥ 6 EFZLB 11-100 EFZLQ 9-100 Self lubrication
HXR 560 2 EFZLB 14-125 EFZLQ 14-125 Oil circulation
HXR 560 4 EFZLB 14-125 EFZLQ 14-125 Oil circulation 1)
HXR 560 6 EFZLB 14-125 EFZLQ 14-125 Self lubrication
HXR 560 ≥ 8 EFZLB 14-140 EFZLQ 14-140 Self lubrication
AMA 400 2 EFZLB 9-80 EFZLQ 9-80 Self lubrication
AMA 400 ≥ 4 EFZLB 9-100 EFZLQ 9-100 Self lubrication
AMA 450 2 EFZLB 9-80 EFZLQ 9-80 Self lubrication
AMA 450 ≥ 4 EFZLB 11-125 EFZLQ 9-100 Self lubrication
AMA 500 2 EFZLB 9-100 EFZLQ 9-100 Oil circulation 1)
AMA 500 4 EFZLB 14-125 EFZLQ 11-125 Self lubrication
AMA 500 ≥ 6 EFZLB 14-140 EFZLQ 11-125 Self lubrication 1) Possibility for self lubrication, please contact ABB
Table below: Sleeve bearings and lubrication method.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 71
3
Vertical motorsVertical motors 355 - 500 have deep groove ball bearing in D-end and single-row angular contact ball bearing in N-end.
The bearing in D-end is axially free in vertical motors when an angular contact ball bearing is mounted in N-end. Standard bearings of vertical motors are stated in table below and the bearing construction is shown in figure below.
Standard bearing solution is designed to carry the weight of the typical coupling half and the weight of the motor rotor only. Any additional radial or axial force caused by driven equipment may require special bearing construction.
Frame size Poles D-end N-end
HXR 355 2 6317M/C3 7317 BMP 1)
HXR 355 ≥ 4 6322/C3 7319 BMP
HXR 400 2 6317M/C3 7317 BMP 2)
HXR 400 ≥ 4 6324/C3 7319 BMP
HXR 450 ≥ 4 6324/C3 7322 BMP
HXR 500 ≥ 4 6326/C3 7324 BMP
AMA 400 ≥ 4 6324/C3 7319 BMP
AMA 450 ≥ 4 6326/C3 7322 BMP
AMA 500 ≥ 4 6330/C3 7324 BMP1) 60 Hz motors have ball bearing 6317M/C3.2) Only for 50 Hz motors.
1 Bearing 2 Inner bearing cover
3 Grease valve 4 Outer bearing cover
5 Circlip 6 Hexagon screw
7 Spring 8 O-ring
Figure below: Standard bearing construction of vertically mounted motor, frame sizes 355 - 500. On the left the bearing is "axially locked" angular contact ball bearing and on the right is an axially free deep groove ball bearing.
Table below: Standard bearings for vertical motors.
72 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Bearing rating life
The bearing rates for all vertical motors with standard bearings have a rated life time L10h in excess of 100000 h. The life times are calculated in accordance with ISO R 281-1.
The basic rated life L10h is the number of hours at rated bearing load and speed that 90% of a group of identical
bearings will complete or exceed before the first evidence of failure.
Additional axial force from the driven equipment is not allowed.
Lubrication intervals
The motors are equipped with greasing nipple(s) in both ends for lubricating the bearings. The amount of grease and the interval of greasing are stamped on the
relubrication plate. The values are also available in the table on page 55.
Vibration limits
Poles Speedrpm
Design Bearing housingvibration
2 1800 < n 3600 Standard 0.1 in./s peak (2.54 mm/s)
≥4 1800 Standard 0.1 in./s peak (2.54 mm/s)
The following table lists the vibration values that the motors fulfil in compliance with IEC 60034-14.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 73
3
Type designation
Frame sizesIEC Equivalent to NEMA series*
355 58xx400 68xx450 72xx500 80xx560 88xx
* The NEMA frames are for reference only. Actual frame heights are presented in the technical section.
The type designation of the AMA motor follows the coding principle shown below.
Example: AMA 450L4A BATH1 AM Stands for Alternating Current Machines2 A Indicates the type of motor, A - E = SCIM, K - P = WRIM3 450 Frame size in mm, 400, 450 or 5004 L Frame length, S = small, M = medium or L = long5 4 Number of poles6 A Stands for the IC/IP combination L = IC81W / IP54 (55) [TEWAC] W = IC01 / IPW24 [WP II] A = IC611 / IP54 (55) [TEAAC]7 B Mounting arrangement, B = IM1001 (Horizontal), V = IM4011 (Vertical)8 A Bearing type, A = antifriction, S = sleeve9 T Indication of special construction T = separate ventilation X = electrically special N = Non-sparking design F = frequency converter drive Y = mechanically special10 H Location of manufacture H = Helsinki (Finland) S = Shanghai (China)
The type designation of the HXR motor follows the coding principle shown below.
Example: HXR 355LA41. HXR Stands for the HXR motor family, three digits.2. 355 Shaft height in mm, three digits.3. L Frame length, one digit.4. A Core length, one digit.5. 4 Number of poles.
74 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
NotesAll ratings in this catalogue are designed for the following: - Horizontal mounting- 3 phase- Class F insulation- Service factor of 1.0- Maximum temperature rise of 80 degrees C by -resistance at 1.0 service factor- Maximum 104 degrees F (40 degrees C) ambient- Altitude of 3300 feet or less
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 75
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors WPII – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
2300 V 60 Hz250 600 AMA 400L12D 289 593 91.9 91.6 0.71 0.65 72 40 394 D 2211 71 181 6041 77
300 600 AMA 400L12D 290 593 92.1 91.7 0.69 0.62 89 52 407 E 2660 76 190 6261 77
350 600 AMA 400L12D 291 593 92.3 92.0 0.70 0.64 101 57 399 E 3101 74 182 6482 77
400 720 AMA 400L10D 278 711 93.3 93.4 0.76 0.71 106 52 419 D 2952 65 179 6063 77
400 600 AMA 400L12D 292 592 92.5 92.4 0.73 0.67 111 57 383 D 3544 69 171 6878 77
450 720 AMA 400L10D 279 711 93.4 93.6 0.76 0.72 118 55 409 D 3330 63 173 6261 77
450 600 AMA 400L12D 293 593 92.7 92.5 0.71 0.65 128 69 397 D 3993 74 178 7099 77
500 900 AMA 400L8D 266 889 94.1 94.4 0.83 0.81 119 43 463 D 2955 74 184 6063 77
500 720 AMA 400L10D 280 711 93.5 93.8 0.77 0.72 131 61 414 D 3696 65 177 6482 77
500 600 AMA 400L12D 294 593 92.8 92.5 0.71 0.64 143 79 412 E 4429 77 185 7518 77
600 900 AMA 400L8D 267 889 94.3 94.6 0.84 0.81 142 49 452 D 3551 73 178 6283 77
600 720 AMA 400L10D 281 711 93.9 94.0 0.77 0.72 156 73 438 E 4435 69 180 7099 77
600 600 AMA 450L12D 295 593 94.0 94.2 0.76 0.72 156 73 422 D 5319 70 180 8686 78
700 900 AMA 400L8D 268 889 94.5 94.8 0.83 0.80 166 60 471 D 4135 78 184 6482 77
700 720 AMA 400L10D 282 711 94.0 94.2 0.77 0.72 181 83 438 E 5168 70 177 7518 77
700 600 AMA 450L12D 296 594 94.1 94.1 0.75 0.69 186 94 441 E 6191 73 191 9171 78
800 1200 AMA 400L6D 256 1187 94.7 95.0 0.83 0.80 190 71 502 E 3542 73 201 6085 79
800 900 AMA 400L8D 269 890 94.5 94.8 0.83 0.80 190 69 477 D 4727 78 185 6856 77
800 720 AMA 450L10D 283 712 94.4 94.7 0.82 0.79 193 73 450 D 5908 73 181 8400 78
800 600 AMA 450L12D 297 594 94.2 94.3 0.76 0.71 209 101 441 E 7083 74 187 9700 78
900 1200 AMA 400L6D 257 1188 94.9 95.1 0.82 0.79 215 84 513 E 3979 76 204 6305 79
900 900 AMA 400L8D 270 889 94.6 94.9 0.83 0.81 213 77 479 E 5313 80 184 7055 77
900 720 AMA 450L10D 284 712 94.5 94.8 0.82 0.79 217 83 455 D 6640 75 181 8664 78
900 600 AMA 500L12D 298 594 94.6 94.7 0.77 0.72 230 107 452 E 7955 69 186 11133 79
1000 3600 AMA 400L2D 237 3579 95.5 95.6 0.89 0.87 220 60 592 F 1468 60 249 6437 85
1000 1800 AMA 400L4D 246 1785 95.1 95.3 0.88 0.86 223 65 530 E 2943 65 213 6283 80
1000 1200 AMA 400L6D 258 1188 95.1 95.3 0.83 0.80 237 91 520 E 4423 78 204 6526 79
1000 900 AMA 400L8D 271 889 94.7 95.1 0.84 0.82 234 79 475 D 5909 80 181 7474 77
1000 720 AMA 450L10D 285 712 94.6 95.0 0.83 0.80 239 86 448 D 7383 73 178 9193 78
1000 600 AMA 500L12D 299 594 94.7 94.9 0.78 0.74 252 111 446 D 8845 68 183 11795 79
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
76 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors WPII – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
2300 V 60 Hz1250 3600 AMA 400L2D 238 3579 95.7 95.8 0.88 0.86 277 80 597 F 1834 62 249 6614 85
1250 1800 AMA 400L4D 247 1785 95.3 95.6 0.88 0.86 280 80 521 E 3678 67 206 6504 80
1250 1200 AMA 400L6D 259 1189 95.3 95.5 0.82 0.79 298 117 535 F 5527 80 204 7099 79
1250 900 AMA 450L8D 272 892 95.3 95.6 0.84 0.81 292 105 509 E 7361 72 193 8708 78
1250 720 AMA 500L10D 286 714 95.3 95.5 0.81 0.77 301 125 515 E 9189 68 203 11486 79
1250 600 AMA 500L12D 300 595 95.0 95.0 0.78 0.73 316 146 476 E 11042 74 195 13118 79
1500 3600 AMA 400L2D 239 3579 95.9 96.1 0.89 0.87 328 87 587 F 2202 59 246 6900 85
1500 1800 AMA 400L4D 248 1784 95.3 95.7 0.87 0.85 338 99 515 E 4417 67 204 6680 80
1500 1200 AMA 450L6D 260 1191 95.6 95.8 0.86 0.83 341 110 543 E 6618 65 205 8774 81
1500 900 AMA 450L8D 273 893 95.6 95.8 0.83 0.79 355 137 522 E 8830 72 195 9502 78
1500 720 AMA 500L10D 287 714 95.4 95.6 0.82 0.78 358 143 504 E 11036 67 196 12147 79
1750 3600 AMA 400L2D 240 3579 96.0 96.3 0.89 0.88 380 94 594 F 2568 65 243 7385 85
1750 1800 AMA 400L4D 249 1785 95.6 96.0 0.89 0.88 385 98 521 E 5149 65 203 7121 80
1750 1200 AMA 450L6D 261 1191 95.7 96.0 0.86 0.83 399 128 535 E 7726 65 202 9061 81
1750 900 AMA 500L8D 274 891 95.6 96.0 0.86 0.84 397 118 492 D 10311 66 192 11177 79
1750 720 AMA 500L10D 288 714 95.6 95.7 0.82 0.79 415 161 509 E 12869 68 196 13140 79
2000 3600 AMA 450L2D 241 3579 96.0 96.0 0.88 0.86 443 124 546 E 2936 51 235 8752 86
2000 1800 AMA 450L4D 250 1784 95.4 95.7 0.87 0.86 448 117 489 D 5889 65 189 8466 81
2000 1200 AMA 450L6D 262 1190 95.8 96.1 0.87 0.85 449 132 544 E 8828 69 204 9590 81
2000 900 AMA 500L8D 275 892 95.6 96.1 0.87 0.85 450 127 499 D 11784 67 193 12170 79
2250 3600 AMA 450L2D 242 3578 96.1 96.3 0.89 0.88 491 119 521 E 3303 49 221 9127 86
2250 1800 AMA 450L4D 251 1785 95.6 95.9 0.87 0.86 504 132 500 D 6626 68 192 8752 81
2250 1200 AMA 500L6D 263 1191 95.8 96.1 0.87 0.85 505 148 538 E 9926 70 205 10913 81
2250 900 AMA 500L8D 276 892 95.8 96.2 0.86 0.85 508 150 508 E 13247 67 191 12831 79
2500 3600 AMA 450L2D 243 3579 96.6 96.7 0.90 0.89 539 124 547 E 3670 54 229 9811 86
2500 1800 AMA 450L4D 252 1786 96.1 96.3 0.89 0.88 547 129 522 E 7354 66 195 9326 81
2500 1200 AMA 500L6D 264 1192 96.3 96.6 0.89 0.87 547 143 549 E 11020 67 206 11640 81
2500 900 AMA 500L8D 511 892 96.0 96.4 0.87 0.86 558 152 504 D 14729 69 193 13404 79
3000 3600 AMA 500L2D 244 3580 96.5 96.5 0.90 0.89 643 147 556 E 4403 53 236 12081 87
3000 1800 AMA 500L4D 253 1790 96.3 96.4 0.87 0.85 669 195 555 E 8804 65 207 11244 83
3000 1200 AMA 500L6D 265 1192 96.4 96.7 0.89 0.89 650 152 541 E 13226 67 200 12632 81
3500 3600 AMA 500L2D 245 3579 96.6 96.7 0.91 0.90 744 153 548 E 5138 54 228 12853 87
3500 1800 AMA 500L4D 254 1790 96.5 96.6 0.88 0.87 770 204 555 E 10271 66 203 11971 83
3500 1200 AMA 500L6D 510 1193 96.6 96.8 0.89 0.88 762 193 562 E 15421 69 204 13558 81
4000 1800 AMA 500L4D 255 1790 96.6 96.8 0.88 0.87 875 221 559 E 11738 68 203 12632 83
4500 1800 AMA 500L4D 509 1790 96.7 96.9 0.89 0.88 974 228 560 E 13206 70 200 13316 83
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 77
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEAAC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
2300 V 60 Hz200 600 AMA 400L12A 566 593 91.6 91.0 0.71 0.64 58 33 419 E 1769 76 200 6415 77
250 600 AMA 400L12A 567 593 91.9 91.4 0.70 0.64 73 41 418 E 2208 77 193 6614 77
300 600 AMA 400L12A 568 593 92.2 91.7 0.70 0.64 87 50 418 E 2658 76 195 7033 77
350 720 AMA 400L10A 555 712 93.1 92.9 0.73 0.67 96 52 444 E 2581 68 196 6415 78
350 600 AMA 400L12A 569 593 92.4 91.9 0.70 0.64 101 57 424 E 3098 79 196 7253 77
400 720 AMA 400L10A 556 712 93.3 93.2 0.75 0.69 107 55 451 E 2948 71 195 6636 78
400 600 AMA 400L12A 570 593 92.6 92.2 0.71 0.65 113 62 419 E 3538 77 191 7672 77
450 900 AMA 400L8A 542 890 94.0 94.0 0.82 0.79 109 43 486 E 2659 75 198 6437 79
450 720 AMA 400L10A 557 712 93.5 93.4 0.75 0.70 120 60 452 E 3325 72 196 6834 78
450 600 AMA 450L12A 571 594 93.7 93.6 0.74 0.68 122 64 453 E 3984 75 204 8620 77
500 900 AMA 400L8A 543 891 94.2 94.2 0.82 0.78 122 50 487 E 2950 74 200 6636 79
500 720 AMA 400L10A 558 713 93.8 93.5 0.73 0.67 137 73 456 E 3685 67 199 7452 78
500 600 AMA 450L12A 572 594 93.7 93.6 0.75 0.69 133 68 453 E 4424 76 198 8841 77
600 900 AMA 400L8A 544 891 94.4 94.4 0.81 0.77 147 61 493 E 3542 76 200 6856 79
600 720 AMA 400L10A 559 713 93.9 93.8 0.74 0.68 162 84 446 E 4427 65 192 7871 78
600 600 AMA 450L12A 573 594 93.9 93.9 0.75 0.69 160 82 460 E 5312 78 199 9370 77
700 1200 AMA 400L6A 531 1189 94.4 94.3 0.81 0.76 172 74 520 F 3092 73 206 6460 81
700 900 AMA 400L8A 545 891 94.4 94.5 0.82 0.78 171 69 491 E 4127 75 198 7209 79
700 720 AMA 450L10A 560 713 94.3 94.4 0.80 0.76 173 73 473 E 5158 72 197 8841 78
700 600 AMA 450L12A 574 595 94.1 94.0 0.74 0.67 189 101 468 F 6184 77 207 10141 77
800 1200 AMA 400L6A 532 1189 94.6 94.5 0.80 0.75 198 88 523 F 3536 74 207 6658 81
800 900 AMA 400L8A 546 891 94.5 94.7 0.82 0.78 193 77 494 E 4721 78 196 7430 79
800 720 AMA 450L10A 561 713 94.4 94.6 0.81 0.77 197 83 481 E 5900 76 197 9105 78
800 600 AMA 500L12A 575 595 94.5 94.4 0.76 0.70 210 107 486 F 7069 74 206 11684 77
900 3600 AMA 400L2A 513 3576 94.6 94.4 0.88 0.85 203 61 578 F 1321 64 247 6482 88
900 1200 AMA 400L6A 533 1189 94.8 94.9 0.81 0.76 220 93 523 F 3974 74 203 6878 81
900 900 AMA 400L8A 548 890 94.7 94.8 0.84 0.80 213 79 511 E 5307 85 198 7848 79
900 720 AMA 450L10A 562 713 94.6 94.8 0.82 0.78 217 86 481 E 6632 77 195 9634 78
900 600 AMA 500L12A 576 595 94.7 94.6 0.77 0.72 231 111 476 E 7947 72 200 12346 77
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
78 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEAAC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
2300 V 60 Hz1000 3600 AMA 400L2A 514 3578 95.0 94.8 0.89 0.87 221 61 594 F 1468 61 251 6768 88
1000 1800 AMA 400L4A 522 1786 94.8 94.8 0.88 0.86 225 66 534 E 2942 61 217 6658 81
1000 1200 AMA 400L6A 534 1190 95.0 94.9 0.80 0.76 246 108 535 F 4415 75 205 7253 81
1000 900 AMA 450L8A 549 892 95.1 95.3 0.85 0.82 232 80 528 E 5890 73 201 9171 79
1000 720 AMA 500L10A 563 715 95.2 95.1 0.80 0.76 244 109 525 F 7349 64 220 11707 78
1000 600 AMA 500L12A 577 595 94.8 94.8 0.79 0.74 251 112 477 E 8837 72 197 13338 77
1250 3600 AMA 400L2A 515 3578 95.2 95.3 0.90 0.89 272 63 586 F 1835 63 242 7209 88
1250 1800 AMA 400L4A 523 1788 95.2 95.3 0.89 0.87 277 80 584 F 3672 69 232 7253 81
1250 1200 AMA 450L6A 535 1191 95.2 95.2 0.85 0.82 289 99 553 F 5515 63 209 8951 81
1250 900 AMA 450L8A 550 892 95.3 95.6 0.85 0.83 288 96 522 E 7357 72 197 9965 79
1250 720 AMA 500L10A 564 714 95.2 95.4 0.83 0.80 294 109 509 E 9193 68 198 12368 78
1500 3600 AMA 400L2A 516 3579 95.6 95.6 0.88 0.86 334 94 620 F 2202 72 254 7518 88
1500 1800 AMA 400L4A 524 1787 95.4 95.6 0.89 0.88 330 89 562 E 4411 68 219 7518 81
1500 1200 AMA 450L6A 536 1191 95.3 95.4 0.86 0.84 343 110 542 E 6619 65 205 9237 81
1500 900 AMA 500L8A 551 893 95.5 95.7 0.85 0.82 346 119 538 E 8828 69 205 11729 79
1500 720 AMA 500L10A 565 714 95.3 95.4 0.83 0.80 353 133 527 E 11032 70 205 13558 78
1750 3600 AMA 450L2A 517 3580 95.3 95.2 0.89 0.87 387 103 557 E 2567 52 240 9215 89
1750 1800 AMA 450L4A 525 1789 95.3 95.2 0.88 0.87 388 111 598 F 5137 67 230 9193 82
1750 1200 AMA 450L6A 537 1192 95.6 95.7 0.85 0.83 401 133 558 F 7719 65 207 10031 81
1750 900 AMA 500L8A 552 893 95.6 95.8 0.86 0.84 398 127 536 E 10294 68 201 12699 79
2000 3600 AMA 450L2A 518 3580 95.6 95.5 0.88 0.87 442 119 566 F 2935 53 242 9546 89
2000 1800 AMA 450L4A 526 1789 95.5 95.5 0.90 0.89 436 104 579 F 5875 66 217 9744 82
2000 1200 AMA 500L6A 538 1192 95.5 95.7 0.88 0.86 447 127 544 E 8818 68 204 11486 81
2000 900 AMA 500L8A 553 893 95.7 95.9 0.85 0.83 457 151 536 E 11766 67 201 13382 79
2250 3600 AMA 450L2A 519 3581 95.8 95.7 0.89 0.87 494 125 566 F 3300 53 237 10229 89
2250 1800 AMA 500L4A 527 1791 95.5 95.5 0.89 0.87 495 134 598 F 6597 66 223 11795 84
2250 1800 AMA 500L4A 8606 1792 95.6 95.5 0.89 0.87 496 141 615 F 6595 66 222 12170 84
2250 1200 AMA 500L6A 539 1192 95.7 95.9 0.88 0.86 501 139 550 E 9920 69 204 12147 81
2250 900 AMA 500L8A 554 893 95.9 96.1 0.85 0.83 512 169 546 E 13232 70 200 14043 79
2500 3600 AMA 500L2A 520 3582 96.0 95.9 0.90 0.89 540 127 583 F 3668 55 245 12610 90
2500 1800 AMA 500L4A 528 1791 96.0 95.9 0.90 0.88 543 139 594 F 7333 67 212 12147 84
2500 1200 AMA 500L6A 540 1193 96.2 96.3 0.88 0.87 551 149 556 E 11015 67 197 13140 81
3000 3600 AMA 500L2A 521 3582 96.3 96.2 0.90 0.89 648 153 597 F 4400 57 247 13338 90
3000 1800 AMA 500L4A 529 1791 96.1 96.2 0.90 0.90 646 140 559 E 8803 65 203 12787 84
3000 1200 AMA 500L6A 541 1193 96.4 96.5 0.89 0.88 650 158 571 E 13215 68 208 14132 81
3500 1800 AMA 500L4A 530 1791 96.4 96.5 0.90 0.90 751 167 581 E 10268 70 211 13536 84
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 79
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEWAC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
2300 V 60 Hz250 600 AMA 400L12L 289 593 91.9 91.6 0.71 0.65 72 40 394 D 2211 71 181 6041 77
300 600 AMA 400L12L 290 593 92.1 91.7 0.69 0.62 89 52 407 E 2660 76 190 6261 77
350 600 AMA 400L12L 291 593 92.3 92.0 0.70 0.64 101 57 399 E 3101 74 182 6482 77
400 720 AMA 400L10L 278 711 93.3 93.4 0.76 0.71 106 52 419 D 2952 65 179 6063 77
400 600 AMA 400L12L 292 592 92.5 92.4 0.73 0.67 111 57 383 D 3544 69 171 6878 77
450 720 AMA 400L10L 279 711 93.4 93.6 0.76 0.72 118 55 409 D 3330 63 173 6261 77
450 600 AMA 400L12L 293 593 92.7 92.5 0.71 0.65 128 69 397 D 3993 74 178 7099 77
500 900 AMA 400L8L 266 889 94.1 94.4 0.83 0.81 119 43 463 D 2955 74 184 6063 77
500 720 AMA 400L10L 280 711 93.5 93.8 0.77 0.72 131 61 414 D 3696 65 177 6482 77
500 600 AMA 400L12L 294 593 92.8 92.5 0.71 0.64 143 79 412 E 4429 77 185 7518 77
600 900 AMA 400L8L 267 889 94.3 94.6 0.84 0.81 142 49 452 D 3551 73 178 6283 77
600 720 AMA 400L10L 281 711 93.9 94.0 0.77 0.72 156 73 438 E 4435 69 180 7099 77
600 600 AMA 450L12L 295 593 94.0 94.2 0.76 0.72 156 73 422 D 5319 70 180 8686 78
700 900 AMA 400L8L 268 889 94.5 94.8 0.83 0.80 166 60 471 D 4135 78 184 6482 77
700 720 AMA 400L10L 282 711 94.0 94.2 0.77 0.72 181 83 438 E 5168 70 177 7518 77
700 600 AMA 450L12L 296 594 94.1 94.1 0.75 0.69 186 94 441 E 6191 73 191 9171 78
800 1200 AMA 400L6L 256 1187 94.7 95.0 0.83 0.80 190 71 502 E 3542 73 201 6085 79
800 900 AMA 400L8L 269 890 94.5 94.8 0.83 0.80 190 69 477 D 4727 78 185 6856 77
800 720 AMA 450L10L 283 712 94.4 94.7 0.82 0.79 193 73 450 D 5908 73 181 8400 78
800 600 AMA 450L12L 297 594 94.2 94.3 0.76 0.71 209 101 441 E 7083 74 187 9700 78
900 1200 AMA 400L6L 257 1188 94.9 95.1 0.82 0.79 215 84 513 E 3979 76 204 6305 79
900 900 AMA 400L8L 270 889 94.6 94.9 0.83 0.81 213 77 479 E 5313 80 184 7055 77
900 720 AMA 450L10L 284 712 94.5 94.8 0.82 0.79 217 83 455 D 6640 75 181 8664 78
900 600 AMA 500L12L 298 594 94.6 94.7 0.77 0.72 230 107 452 E 7955 69 186 11133 79
1000 3600 AMA 400L2L 237 3579 95.5 95.6 0.89 0.87 220 60 592 F 1468 60 249 6437 85
1000 1800 AMA 400L4L 246 1785 95.1 95.3 0.88 0.86 223 65 530 E 2943 65 213 6283 80
1000 1200 AMA 400L6L 258 1188 95.1 95.3 0.83 0.80 237 91 520 E 4423 78 204 6526 79
1000 900 AMA 400L8L 271 889 94.7 95.1 0.84 0.82 234 79 475 D 5909 80 181 7474 77
1000 720 AMA 450L10L 285 712 94.6 95.0 0.83 0.80 239 86 448 D 7383 73 178 9193 78
1000 600 AMA 500L12L 299 594 94.7 94.9 0.78 0.74 252 111 446 D 8845 68 183 11795 79
80 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEWAC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
2300 V 60 Hz1250 3600 AMA 400L2L 238 3579 95.7 95.8 0.88 0.86 277 80 597 F 1834 62 249 6614 85
1250 1800 AMA 400L4L 247 1785 95.3 95.6 0.88 0.86 280 80 521 E 3678 67 206 6504 80
1250 1200 AMA 400L6L 259 1189 95.3 95.5 0.82 0.79 298 117 535 F 5527 80 204 7099 79
1250 900 AMA 450L8L 272 892 95.3 95.6 0.84 0.81 292 105 509 E 7361 72 193 8708 78
1250 720 AMA 500L10L 286 714 95.3 95.5 0.81 0.77 301 125 515 E 9189 68 203 11486 79
1250 600 AMA 500L12L 300 595 95.0 95.0 0.78 0.73 316 146 476 E 11042 74 195 13118 79
1500 3600 AMA 400L2L 239 3579 95.9 96.1 0.89 0.87 328 87 587 F 2202 59 246 6900 85
1500 1800 AMA 400L4L 248 1784 95.3 95.7 0.87 0.85 338 99 515 E 4417 67 204 6680 80
1500 1200 AMA 450L6L 260 1191 95.6 95.8 0.86 0.83 341 110 543 E 6618 65 205 8774 81
1500 900 AMA 450L8L 273 893 95.6 95.8 0.83 0.79 355 137 522 E 8830 72 195 9502 78
1500 720 AMA 500L10L 287 714 95.4 95.6 0.82 0.78 358 143 504 E 11036 67 196 12147 79
1750 3600 AMA 400L2L 240 3579 96.0 96.3 0.89 0.88 380 94 594 F 2568 65 243 7385 85
1750 1800 AMA 400L4L 249 1785 95.6 96.0 0.89 0.88 385 98 521 E 5149 65 203 7121 80
1750 1200 AMA 450L6L 261 1191 95.7 96.0 0.86 0.83 399 128 535 E 7726 65 202 9061 81
1750 900 AMA 500L8L 274 891 95.6 96.0 0.86 0.84 397 118 492 D 10311 66 192 11177 79
1750 720 AMA 500L10L 288 714 95.6 95.7 0.82 0.79 415 161 509 E 12869 68 196 13140 79
2000 3600 AMA 450L2L 241 3579 96.0 96.0 0.88 0.86 443 124 546 E 2936 51 235 8752 86
2000 1800 AMA 450L4L 250 1784 95.4 95.7 0.87 0.86 448 117 489 D 5889 65 189 8466 81
2000 1200 AMA 450L6L 262 1190 95.8 96.1 0.87 0.85 449 132 544 E 8828 69 204 9590 81
2000 900 AMA 500L8L 275 892 95.6 96.1 0.87 0.85 450 127 499 D 11784 67 193 12170 79
2250 3600 AMA 450L2L 242 3578 96.1 96.3 0.89 0.88 491 119 521 E 3303 49 221 9127 86
2250 1800 AMA 450L4L 251 1785 95.6 95.9 0.87 0.86 504 132 500 D 6626 68 192 8752 81
2250 1200 AMA 500L6L 263 1191 95.8 96.1 0.87 0.85 505 148 538 E 9926 70 205 10913 81
2250 900 AMA 500L8L 276 892 95.8 96.2 0.86 0.85 508 150 508 E 13247 67 191 12831 79
2500 3600 AMA 450L2L 243 3579 96.6 96.7 0.90 0.89 539 124 547 E 3670 54 229 9811 86
2500 1800 AMA 450L4L 252 1786 96.1 96.3 0.89 0.88 547 129 522 E 7354 66 195 9326 81
2500 1200 AMA 500L6L 264 1192 96.3 96.6 0.89 0.87 547 143 549 E 11020 67 206 11640 81
2500 900 AMA 500L8L 511 892 96.0 96.4 0.87 0.86 558 152 504 D 14729 69 193 13404 79
3000 3600 AMA 500L2L 244 3580 96.5 96.5 0.90 0.89 643 147 556 E 4403 53 236 12081 87
3000 1800 AMA 500L4L 253 1790 96.3 96.4 0.87 0.85 669 195 555 E 8804 65 207 11244 83
3000 1200 AMA 500L6L 265 1192 96.4 96.7 0.89 0.89 650 152 541 E 13226 67 200 12632 81
3500 3600 AMA 500L2L 245 3579 96.6 96.7 0.91 0.90 744 153 548 E 5138 54 228 12853 87
3500 1800 AMA 500L4L 254 1790 96.5 96.6 0.88 0.87 770 204 555 E 10271 66 203 11971 83
3500 1200 AMA 500L6L 510 1193 96.6 96.8 0.89 0.88 762 193 562 E 15421 69 204 13558 81
4000 1800 AMA 500L4L 255 1790 96.6 96.8 0.88 0.87 875 221 559 E 11738 68 203 12632 83
4500 1800 AMA 500L4L 509 1790 96.7 96.9 0.89 0.88 974 228 560 E 13206 70 200 13316 83
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 81
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors WPII – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
4000 V 60 Hz250 600 AMA 400L12D 289 593 91.9 91.6 0.71 0.65 41 22 394 D 2211 71 181 6041 77
300 600 AMA 400L12D 290 593 92.1 91.7 0.69 0.62 51 29 407 E 2660 76 190 6261 77
350 600 AMA 400L12D 291 593 92.3 92.0 0.70 0.64 58 32 399 E 3101 74 182 6482 77
400 720 AMA 400L10D 278 711 93.3 93.4 0.76 0.71 61 29 419 D 2952 65 179 6063 77
400 600 AMA 400L12D 292 592 92.5 92.4 0.73 0.67 64 32 383 D 3544 69 171 6878 77
450 720 AMA 400L10D 279 711 93.4 93.6 0.76 0.72 68 31 409 D 3330 63 173 6261 77
450 600 AMA 400L12D 293 593 92.7 92.5 0.71 0.65 73 39 397 D 3993 74 178 7099 77
500 900 AMA 400L8D 266 889 94.1 94.4 0.83 0.81 68 24 463 D 2955 74 184 6063 77
500 720 AMA 400L10D 280 711 93.5 93.8 0.77 0.72 75 34 414 D 3696 65 177 6482 77
500 600 AMA 400L12D 294 593 92.8 92.5 0.71 0.64 82 45 412 E 4429 77 185 7518 77
600 900 AMA 400L8D 267 889 94.3 94.6 0.84 0.81 82 28 452 D 3551 73 178 6283 77
600 720 AMA 400L10D 281 711 93.9 94.0 0.77 0.72 90 41 438 E 4435 69 180 7099 77
600 600 AMA 450L12D 295 593 94.0 94.2 0.76 0.72 90 42 422 D 5319 70 180 8686 78
700 900 AMA 400L8D 268 889 94.5 94.8 0.83 0.80 96 34 471 D 4135 78 184 6482 77
700 720 AMA 400L10D 282 711 94.0 94.2 0.77 0.72 104 47 438 E 5168 70 177 7518 77
700 600 AMA 450L12D 296 594 94.1 94.1 0.75 0.69 107 54 441 E 6191 73 191 9171 78
800 1200 AMA 400L6D 256 1187 94.7 95.0 0.83 0.80 109 41 502 E 3542 73 201 6085 79
800 900 AMA 400L8D 269 890 94.5 94.8 0.83 0.80 109 39 477 D 4727 78 185 6856 77
800 720 AMA 450L10D 283 712 94.4 94.7 0.82 0.79 111 42 450 D 5908 73 181 8400 78
800 600 AMA 450L12D 297 594 94.2 94.3 0.76 0.71 120 58 441 E 7083 74 187 9700 78
900 1200 AMA 400L6D 257 1188 94.9 95.1 0.82 0.79 124 48 513 E 3979 76 204 6305 79
900 900 AMA 400L8D 270 889 94.6 94.9 0.83 0.81 123 44 479 E 5313 80 184 7055 77
900 720 AMA 450L10D 284 712 94.5 94.8 0.82 0.79 125 47 455 D 6640 75 181 8664 78
900 600 AMA 500L12D 298 594 94.6 94.7 0.77 0.72 132 61 452 E 7955 69 186 11133 79
1000 3600 AMA 400L2D 237 3579 95.5 95.6 0.89 0.87 127 34 592 F 1468 60 249 6437 85
1000 1800 AMA 400L4D 246 1785 95.1 95.3 0.88 0.86 129 37 530 E 2943 65 213 6283 80
1000 1200 AMA 400L6D 258 1188 95.1 95.3 0.83 0.80 136 51 520 E 4423 78 204 6526 79
1000 900 AMA 400L8D 271 889 94.7 95.1 0.84 0.82 135 45 475 D 5909 80 181 7474 77
1000 720 AMA 450L10D 285 712 94.6 95.0 0.83 0.80 137 49 448 D 7383 73 178 9193 78
1000 600 AMA 500L12D 299 594 94.7 94.9 0.78 0.74 145 63 446 D 8845 68 183 11795 79
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
82 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors WPII – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
4000 V 60 Hz1250 3600 AMA 400L2D 238 3579 95.7 95.8 0.88 0.86 160 46 597 F 1834 62 249 6614 85
1250 1800 AMA 400L4D 247 1785 95.3 95.6 0.88 0.86 161 45 521 E 3678 67 206 6504 80
1250 1200 AMA 400L6D 259 1189 95.3 95.5 0.82 0.79 172 67 535 F 5527 80 204 7099 79
1250 900 AMA 450L8D 272 892 95.3 95.6 0.84 0.81 168 60 509 E 7361 72 193 8708 78
1250 720 AMA 500L10D 286 714 95.3 95.5 0.81 0.77 173 71 515 E 9189 68 203 11486 79
1250 600 AMA 500L12D 300 595 95.0 95.0 0.78 0.73 182 84 476 E 11042 74 195 13118 79
1500 3600 AMA 400L2D 239 3579 95.9 96.1 0.89 0.87 189 50 587 F 2202 59 246 6900 85
1500 1800 AMA 400L4D 248 1784 95.3 95.7 0.87 0.85 195 57 515 E 4417 67 204 6680 80
1500 1200 AMA 450L6D 260 1191 95.6 95.8 0.86 0.83 197 63 543 E 6618 65 205 8774 81
1500 900 AMA 450L8D 273 893 95.6 95.8 0.83 0.79 205 79 522 E 8830 72 195 9502 78
1500 720 AMA 500L10D 287 714 95.4 95.6 0.82 0.78 207 82 504 E 11036 67 196 12147 79
1750 3600 AMA 400L2D 240 3579 96.0 96.3 0.89 0.88 219 54 594 F 2568 65 243 7385 85
1750 1800 AMA 400L4D 249 1785 95.6 96.0 0.89 0.88 222 56 521 E 5149 65 203 7121 80
1750 1200 AMA 450L6D 261 1191 95.7 96.0 0.86 0.83 230 73 535 E 7726 65 202 9061 81
1750 900 AMA 500L8D 274 891 95.6 96.0 0.86 0.84 229 68 492 D 10311 66 192 11177 79
1750 720 AMA 500L10D 288 714 95.6 95.7 0.82 0.79 239 92 509 E 12869 68 196 13140 79
2000 3600 AMA 450L2D 241 3579 96.0 96.0 0.88 0.86 255 71 546 E 2936 51 235 8752 86
2000 1800 AMA 450L4D 250 1784 95.4 95.7 0.87 0.86 259 67 489 D 5889 65 189 8466 81
2000 1200 AMA 450L6D 262 1190 95.8 96.1 0.87 0.85 259 76 544 E 8828 69 204 9590 81
2000 900 AMA 500L8D 275 892 95.6 96.1 0.87 0.85 260 73 499 D 11784 67 193 12170 79
2250 3600 AMA 450L2D 242 3578 96.1 96.3 0.89 0.88 283 68 521 E 3303 49 221 9127 86
2250 1800 AMA 450L4D 251 1785 95.6 95.9 0.87 0.86 291 75 500 D 6626 68 192 8752 81
2250 1200 AMA 500L6D 263 1191 95.8 96.1 0.87 0.85 291 85 538 E 9926 70 205 10913 81
2250 900 AMA 500L8D 276 892 95.8 96.2 0.86 0.85 293 86 508 E 13247 67 191 12831 79
2500 3600 AMA 450L2D 243 3579 96.6 96.7 0.90 0.89 311 71 547 E 3670 54 229 9811 86
2500 1800 AMA 450L4D 252 1786 96.1 96.3 0.89 0.88 315 74 522 E 7354 66 195 9326 81
2500 1200 AMA 500L6D 264 1192 96.3 96.6 0.89 0.87 316 82 549 E 11020 67 206 11640 81
2500 900 AMA 500L8D 511 892 96.0 96.4 0.87 0.86 322 87 504 D 14729 69 193 13404 79
3000 3600 AMA 500L2D 244 3580 96.5 96.5 0.90 0.89 371 84 556 E 4403 53 236 12081 87
3000 1800 AMA 500L4D 253 1790 96.3 96.4 0.87 0.85 386 112 555 E 8804 65 207 11244 83
3000 1200 AMA 500L6D 265 1192 96.4 96.7 0.89 0.89 375 87 541 E 13226 67 200 12632 81
3500 3600 AMA 500L2D 245 3579 96.6 96.7 0.91 0.90 430 88 548 E 5138 54 228 12853 87
3500 1800 AMA 500L4D 254 1790 96.5 96.6 0.88 0.87 445 117 555 E 10271 66 203 11971 83
3500 1200 AMA 500L6D 510 1193 96.6 96.8 0.89 0.88 439 111 562 E 15421 69 204 13558 81
4000 1800 AMA 500L4D 255 1790 96.6 96.8 0.88 0.87 505 127 559 E 11738 68 203 12632 83
4500 1800 AMA 500L4D 509 1790 96.7 96.9 0.89 0.88 562 131 560 E 13206 70 200 13316 83
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 83
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEAAC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
4000 V 60 Hz200 600 AMA 400L12A 566 593 91.6 91.0 0.71 0.64 33 18 419 E 1769 76 200 6415 77
250 600 AMA 400L12A 567 593 91.9 91.4 0.70 0.64 41 23 418 E 2208 77 193 6614 77
300 600 AMA 400L12A 568 593 92.2 91.7 0.70 0.64 50 28 418 E 2658 76 195 7033 77
350 720 AMA 400L10A 555 712 93.1 92.9 0.73 0.67 55 29 444 E 2581 68 196 6415 78
350 600 AMA 400L12A 569 593 92.4 91.9 0.70 0.64 58 32 424 E 3098 79 196 7253 77
400 720 AMA 400L10A 556 712 93.3 93.2 0.75 0.69 61 31 451 E 2948 71 195 6636 78
400 600 AMA 400L12A 570 593 92.6 92.2 0.71 0.65 65 35 419 E 3538 77 191 7672 77
450 900 AMA 400L8A 542 890 94.0 94.0 0.82 0.79 63 24 486 E 2659 75 198 6437 79
450 720 AMA 400L10A 557 712 93.5 93.4 0.75 0.70 69 34 452 E 3325 72 196 6834 78
450 600 AMA 450L12A 571 594 93.7 93.6 0.74 0.68 70 36 453 E 3984 75 204 8620 77
500 900 AMA 400L8A 543 891 94.2 94.2 0.82 0.78 70 28 487 E 2950 74 200 6636 79
500 720 AMA 400L10A 558 713 93.8 93.5 0.73 0.67 78 42 456 E 3685 67 199 7452 78
500 600 AMA 450L12A 572 594 93.7 93.6 0.75 0.69 76 38 453 E 4424 76 198 8841 77
600 900 AMA 400L8A 544 891 94.4 94.4 0.81 0.77 84 34 493 E 3542 76 200 6856 79
600 720 AMA 400L10A 559 713 93.9 93.8 0.74 0.68 93 48 446 E 4427 65 192 7871 78
600 600 AMA 450L12A 573 594 93.9 93.9 0.75 0.69 92 46 460 E 5312 78 199 9370 77
700 1200 AMA 400L6A 531 1189 94.4 94.3 0.81 0.76 99 42 520 F 3092 73 206 6460 81
700 900 AMA 400L8A 545 891 94.4 94.5 0.82 0.78 98 39 491 E 4127 75 198 7209 79
700 720 AMA 450L10A 560 713 94.3 94.4 0.80 0.76 99 42 473 E 5158 72 197 8841 78
700 600 AMA 450L12A 574 595 94.1 94.0 0.74 0.67 109 58 468 F 6184 77 207 10141 77
800 1200 AMA 400L6A 532 1189 94.6 94.5 0.80 0.75 114 50 523 F 3536 74 207 6658 81
800 900 AMA 400L8A 546 891 94.5 94.7 0.82 0.78 111 44 494 E 4721 78 196 7430 79
800 720 AMA 450L10A 561 713 94.4 94.6 0.81 0.77 113 47 481 E 5900 76 197 9105 78
800 600 AMA 500L12A 575 595 94.5 94.4 0.76 0.70 121 61 486 F 7069 74 206 11684 77
900 3600 AMA 400L2A 513 3576 94.6 94.4 0.88 0.85 117 35 578 F 1321 64 247 6482 88
900 1200 AMA 400L6A 533 1189 94.8 94.9 0.81 0.76 126 53 523 F 3974 74 203 6878 81
900 900 AMA 400L8A 548 890 94.7 94.8 0.84 0.80 122 45 511 E 5307 85 198 7848 79
900 720 AMA 450L10A 562 713 94.6 94.8 0.82 0.78 125 49 481 E 6632 77 195 9634 78
900 600 AMA 500L12A 576 595 94.7 94.6 0.77 0.72 133 63 476 E 7947 72 200 12346 77
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
84 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEAAC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
4000 V 60 Hz1000 3600 AMA 400L2A 514 3578 95.0 94.8 0.89 0.87 127 34 594 F 1468 61 251 6768 88
1000 1800 AMA 400L4A 522 1786 94.8 94.8 0.88 0.86 129 37 534 E 2942 61 217 6658 81
1000 1200 AMA 400L6A 534 1190 95.0 94.9 0.80 0.76 141 62 535 F 4415 75 205 7253 81
1000 900 AMA 450L8A 549 892 95.1 95.3 0.85 0.82 133 45 528 E 5890 73 201 9171 79
1000 720 AMA 500L10A 563 715 95.2 95.1 0.80 0.76 141 62 525 F 7349 64 220 11707 78
1000 600 AMA 500L12A 577 595 94.8 94.8 0.79 0.74 144 64 477 E 8837 72 197 13338 77
1250 3600 AMA 400L2A 515 3578 95.2 95.3 0.90 0.89 156 36 586 F 1835 63 242 7209 88
1250 1800 AMA 400L4A 523 1788 95.2 95.3 0.89 0.87 159 46 584 F 3672 69 232 7253 81
1250 1200 AMA 450L6A 535 1191 95.2 95.2 0.85 0.82 166 57 553 F 5515 63 209 8951 81
1250 900 AMA 450L8A 550 892 95.3 95.6 0.85 0.83 166 55 522 E 7357 72 197 9965 79
1250 720 AMA 500L10A 564 714 95.2 95.4 0.83 0.80 169 62 509 E 9193 68 198 12368 78
1500 3600 AMA 400L2A 516 3579 95.6 95.6 0.88 0.86 192 54 620 F 2202 72 254 7518 88
1500 1800 AMA 400L4A 524 1787 95.4 95.6 0.89 0.88 190 51 562 E 4411 68 219 7518 81
1500 1200 AMA 450L6A 536 1191 95.3 95.4 0.86 0.84 197 63 542 E 6619 65 205 9237 81
1500 900 AMA 500L8A 551 893 95.5 95.7 0.85 0.82 199 68 538 E 8828 69 205 11729 79
1500 720 AMA 500L10A 565 714 95.3 95.4 0.83 0.80 203 76 527 E 11032 70 205 13558 78
1750 3600 AMA 450L2A 517 3580 95.3 95.2 0.89 0.87 223 59 557 E 2567 52 240 9215 89
1750 1800 AMA 450L4A 525 1789 95.3 95.2 0.88 0.87 224 64 598 F 5137 67 230 9193 82
1750 1200 AMA 450L6A 537 1192 95.6 95.7 0.85 0.83 231 76 558 F 7719 65 207 10031 81
1750 900 AMA 500L8A 552 893 95.6 95.8 0.86 0.84 229 73 536 E 10294 68 201 12699 79
2000 3600 AMA 450L2A 518 3580 95.6 95.5 0.88 0.87 255 68 566 F 2935 53 242 9546 89
2000 1800 AMA 450L4A 526 1789 95.5 95.5 0.90 0.89 251 59 579 F 5875 66 217 9744 82
2000 1200 AMA 500L6A 538 1192 95.5 95.7 0.88 0.86 257 73 544 E 8818 68 204 11486 81
2000 900 AMA 500L8A 553 893 95.7 95.9 0.85 0.83 263 86 536 E 11766 67 201 13382 79
2250 3600 AMA 450L2A 519 3581 95.8 95.7 0.89 0.87 285 71 566 F 3300 53 237 10229 89
2250 1800 AMA 500L4A 527 1791 95.5 95.5 0.89 0.87 285 77 598 F 6597 66 223 11795 84
2250 1800 AMA 500L4A 8606 1792 95.6 95.5 0.89 0.87 286 81 615 F 6595 66 222 12170 84
2250 1200 AMA 500L6A 539 1192 95.7 95.9 0.88 0.86 288 80 550 E 9920 69 204 12147 81
2250 900 AMA 500L8A 554 893 95.9 96.1 0.85 0.83 295 97 546 E 13232 70 200 14043 79
2500 3600 AMA 500L2A 520 3582 96.0 95.9 0.90 0.89 311 73 583 F 3668 55 245 12610 90
2500 1800 AMA 500L4A 528 1791 96.0 95.9 0.90 0.88 313 79 594 F 7333 67 212 12147 84
2500 1200 AMA 500L6A 540 1193 96.2 96.3 0.88 0.87 317 86 556 E 11015 67 197 13140 81
3000 3600 AMA 500L2A 521 3582 96.3 96.2 0.90 0.89 373 88 597 F 4400 57 247 13338 90
3000 1800 AMA 500L4A 529 1791 96.1 96.2 0.90 0.90 372 80 559 E 8803 65 203 12787 84
3000 1200 AMA 500L6A 541 1193 96.4 96.5 0.89 0.88 375 91 571 E 13215 68 208 14132 81
3500 1800 AMA 500L4A 530 1791 96.4 96.5 0.90 0.90 433 96 581 E 10268 70 211 13536 84
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 85
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEWAC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
4000 V 60 Hz250 600 AMA 400L12L 289 593 91.9 91.6 0.71 0.65 41 22 394 D 2211 71 181 6041 77
300 600 AMA 400L12L 290 593 92.1 91.7 0.69 0.62 51 29 407 E 2660 76 190 6261 77
350 600 AMA 400L12L 291 593 92.3 92.0 0.70 0.64 58 32 399 E 3101 74 182 6482 77
400 720 AMA 400L10L 278 711 93.3 93.4 0.76 0.71 61 29 419 D 2952 65 179 6063 77
400 600 AMA 400L12L 292 592 92.5 92.4 0.73 0.67 64 32 383 D 3544 69 171 6878 77
450 720 AMA 400L10L 279 711 93.4 93.6 0.76 0.72 68 31 409 D 3330 63 173 6261 77
450 600 AMA 400L12L 293 593 92.7 92.5 0.71 0.65 73 39 397 D 3993 74 178 7099 77
500 900 AMA 400L8L 266 889 94.1 94.4 0.83 0.81 68 24 463 D 2955 74 184 6063 77
500 720 AMA 400L10L 280 711 93.5 93.8 0.77 0.72 75 34 414 D 3696 65 177 6482 77
500 600 AMA 400L12L 294 593 92.8 92.5 0.71 0.64 82 45 412 E 4429 77 185 7518 77
600 900 AMA 400L8L 267 889 94.3 94.6 0.84 0.81 82 28 452 D 3551 73 178 6283 77
600 720 AMA 400L10L 281 711 93.9 94.0 0.77 0.72 90 41 438 E 4435 69 180 7099 77
600 600 AMA 450L12L 295 593 94.0 94.2 0.76 0.72 90 42 422 D 5319 70 180 8686 78
700 900 AMA 400L8L 268 889 94.5 94.8 0.83 0.80 96 34 471 D 4135 78 184 6482 77
700 720 AMA 400L10L 282 711 94.0 94.2 0.77 0.72 104 47 438 E 5168 70 177 7518 77
700 600 AMA 450L12L 296 594 94.1 94.1 0.75 0.69 107 54 441 E 6191 73 191 9171 78
800 1200 AMA 400L6L 256 1187 94.7 95.0 0.83 0.80 109 41 502 E 3542 73 201 6085 79
800 900 AMA 400L8L 269 890 94.5 94.8 0.83 0.80 109 39 477 D 4727 78 185 6856 77
800 720 AMA 450L10L 283 712 94.4 94.7 0.82 0.79 111 42 450 D 5908 73 181 8400 78
800 600 AMA 450L12L 297 594 94.2 94.3 0.76 0.71 120 58 441 E 7083 74 187 9700 78
900 1200 AMA 400L6L 257 1188 94.9 95.1 0.82 0.79 124 48 513 E 3979 76 204 6305 79
900 900 AMA 400L8L 270 889 94.6 94.9 0.83 0.81 123 44 479 E 5313 80 184 7055 77
900 720 AMA 450L10L 284 712 94.5 94.8 0.82 0.79 125 47 455 D 6640 75 181 8664 78
900 600 AMA 500L12L 298 594 94.6 94.7 0.77 0.72 132 61 452 E 7955 69 186 11133 79
1000 3600 AMA 400L2L 237 3579 95.5 95.6 0.89 0.87 127 34 592 F 1468 60 249 6437 85
1000 1800 AMA 400L4L 246 1785 95.1 95.3 0.88 0.86 129 37 530 E 2943 65 213 6283 80
1000 1200 AMA 400L6L 258 1188 95.1 95.3 0.83 0.80 136 51 520 E 4423 78 204 6526 79
1000 900 AMA 400L8L 271 889 94.7 95.1 0.84 0.82 135 45 475 D 5909 80 181 7474 77
1000 720 AMA 450L10L 285 712 94.6 95.0 0.83 0.80 137 49 448 D 7383 73 178 9193 78
1000 600 AMA 500L12L 299 594 94.7 94.9 0.78 0.74 145 63 446 D 8845 68 183 11795 79
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
86 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Modular induction motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEWAC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
400 68xx
450 72xx
500 80xx
4000 V 60 Hz1250 3600 AMA 400L2L 238 3579 95.7 95.8 0.88 0.86 160 46 597 F 1834 62 249 6614 85
1250 1800 AMA 400L4L 247 1785 95.3 95.6 0.88 0.86 161 45 521 E 3678 67 206 6504 80
1250 1200 AMA 400L6L 259 1189 95.3 95.5 0.82 0.79 172 67 535 F 5527 80 204 7099 79
1250 900 AMA 450L8L 272 892 95.3 95.6 0.84 0.81 168 60 509 E 7361 72 193 8708 78
1250 720 AMA 500L10L 286 714 95.3 95.5 0.81 0.77 173 71 515 E 9189 68 203 11486 79
1250 600 AMA 500L12L 300 595 95.0 95.0 0.78 0.73 182 84 476 E 11042 74 195 13118 79
1500 3600 AMA 400L2L 239 3579 95.9 96.1 0.89 0.87 189 50 587 F 2202 59 246 6900 85
1500 1800 AMA 400L4L 248 1784 95.3 95.7 0.87 0.85 195 57 515 E 4417 67 204 6680 80
1500 1200 AMA 450L6L 260 1191 95.6 95.8 0.86 0.83 197 63 543 E 6618 65 205 8774 81
1500 900 AMA 450L8L 273 893 95.6 95.8 0.83 0.79 205 79 522 E 8830 72 195 9502 78
1500 720 AMA 500L10L 287 714 95.4 95.6 0.82 0.78 207 82 504 E 11036 67 196 12147 79
1750 3600 AMA 400L2L 240 3579 96.0 96.3 0.89 0.88 219 54 594 F 2568 65 243 7385 85
1750 1800 AMA 400L4L 249 1785 95.6 96.0 0.89 0.88 222 56 521 E 5149 65 203 7121 80
1750 1200 AMA 450L6L 261 1191 95.7 96.0 0.86 0.83 230 73 535 E 7726 65 202 9061 81
1750 900 AMA 500L8L 274 891 95.6 96.0 0.86 0.84 229 68 492 D 10311 66 192 11177 79
1750 720 AMA 500L10L 288 714 95.6 95.7 0.82 0.79 239 92 509 E 12869 68 196 13140 79
2000 3600 AMA 450L2L 241 3579 96.0 96.0 0.88 0.86 255 71 546 E 2936 51 235 8752 86
2000 1800 AMA 450L4L 250 1784 95.4 95.7 0.87 0.86 259 67 489 D 5889 65 189 8466 81
2000 1200 AMA 450L6L 262 1190 95.8 96.1 0.87 0.85 259 76 544 E 8828 69 204 9590 81
2000 900 AMA 500L8L 275 892 95.6 96.1 0.87 0.85 260 73 499 D 11784 67 193 12170 79
2250 3600 AMA 450L2L 242 3578 96.1 96.3 0.89 0.88 283 68 521 E 3303 49 221 9127 86
2250 1800 AMA 450L4L 251 1785 95.6 95.9 0.87 0.86 291 75 500 D 6626 68 192 8752 81
2250 1200 AMA 500L6L 263 1191 95.8 96.1 0.87 0.85 291 85 538 E 9926 70 205 10913 81
2250 900 AMA 500L8L 276 892 95.8 96.2 0.86 0.85 293 86 508 E 13247 67 191 12831 79
2500 3600 AMA 450L2L 243 3579 96.6 96.7 0.90 0.89 311 71 547 E 3670 54 229 9811 86
2500 1800 AMA 450L4L 252 1786 96.1 96.3 0.89 0.88 315 74 522 E 7354 66 195 9326 81
2500 1200 AMA 500L6L 264 1192 96.3 96.6 0.89 0.87 316 82 549 E 11020 67 206 11640 81
2500 900 AMA 500L8L 511 892 96.0 96.4 0.87 0.86 322 87 504 D 14729 69 193 13404 79
3000 3600 AMA 500L2L 244 3580 96.5 96.5 0.90 0.89 371 84 556 E 4403 53 236 12081 87
3000 1800 AMA 500L4L 253 1790 96.3 96.4 0.87 0.85 386 112 555 E 8804 65 207 11244 83
3000 1200 AMA 500L6L 265 1192 96.4 96.7 0.89 0.89 375 87 541 E 13226 67 200 12632 81
3500 3600 AMA 500L2L 245 3579 96.6 96.7 0.91 0.90 430 88 548 E 5138 54 228 12853 87
3500 1800 AMA 500L4L 254 1790 96.5 96.6 0.88 0.87 445 117 555 E 10271 66 203 11971 83
3500 1200 AMA 500L6L 510 1193 96.6 96.8 0.89 0.88 439 111 562 E 15421 69 204 13558 81
4000 1800 AMA 500L4L 255 1790 96.6 96.8 0.88 0.87 505 127 559 E 11738 68 203 12632 83
4500 1800 AMA 500L4L 509 1790 96.7 96.9 0.89 0.88 562 131 560 E 13206 70 200 13316 83
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 87
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Cast iron motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEFC – Insulation class F, temperature rise class B, S.F. 1.0
2300 V 60 Hz
IEC frame size NEMA frame size
355 58xx
400 68xx
450 72xx
500 80xx
560 88xx
2300 V 60 Hz150 3600 HXR 355LA2 75 3570 91.6 90.4 0.89 0.87 34 648 G 11 221 68 291 3483 89
150 1800 HXR 355LA4 184 1785 92.6 91.6 0.82 0.77 37 610 G 16 442 100 242 3505 82
150 1200 HXR 355LA6 299 1189 93.0 92.3 0.77 0.72 39 524 F 19 663 95 212 3483 80
200 3600 HXR 355LA2 76 3570 92.7 91.9 0.90 0.88 45 653 G 13 294 67 280 3483 89
200 1800 HXR 355LA4 185 1786 93.6 92.9 0.84 0.80 48 633 G 19 587 98 237 3682 82
200 1200 HXR 355LA6 300 1189 93.7 93.2 0.78 0.73 51 542 F 24 883 102 211 3704 80
200 900 HXR 400LA8 409 891 94.0 93.8 0.77 0.72 52 492 F 24 1178 92 197 5027 75
200 720 HXR 400LB10 498 714 93.6 93.1 0.69 0.62 58 468 F 33 1469 83 200 5445 79
200 600 HXR 400LC12 584 594 93.2 93.0 0.68 0.61 59 398 E 34 1768 82 172 5732 75
250 3600 HXR 355LA2 77 3570 93.3 92.7 0.89 0.87 56 656 G 17 367 69 282 3483 89
250 1800 HXR 355LA4 186 1786 94.1 93.7 0.85 0.82 58 633 G 21 733 93 236 3704 82
250 1200 HXR 355LA6 301 1190 94.0 93.7 0.78 0.73 63 544 F 30 1101 92 213 3682 80
250 900 HXR 400LA8 410 891 94.2 94.3 0.80 0.76 62 493 E 26 1470 83 198 5137 75
250 720 HXR 400LC10 499 714 93.9 93.6 0.72 0.66 69 453 F 37 1836 82 185 5732 79
250 600 HXR 400LE12 585 594 93.5 93.2 0.68 0.62 73 404 E 41 2207 84 172 6261 75
300 3600 HXR 355LA2 78 3569 93.9 93.5 0.91 0.89 66 657 G 17 442 72 275 3682 89
300 1800 HXR 355LA4 187 1785 94.4 94.1 0.85 0.82 70 614 G 25 884 92 223 3704 82
300 1200 HXR 355LB6 302 1190 94.5 94.4 0.80 0.75 75 548 F 32 1326 96 206 3858 80
300 900 HXR 400LB8 411 891 94.6 94.7 0.81 0.77 74 494 E 30 1770 84 194 5423 75
300 720 HXR 400LD10 500 714 94.1 93.9 0.72 0.66 83 455 E 43 2211 83 182 6019 79
300 600 HXR 400LG12 586 594 93.7 93.5 0.69 0.63 87 404 E 48 2657 84 170 6834 75
350 3600 HXR 355LB2 79 3570 94.3 94.1 0.91 0.89 77 656 G 20 515 71 268 3902 89
350 1800 HXR 355LB4 188 1786 94.8 94.5 0.86 0.82 81 651 G 28 1029 101 230 3902 82
350 1200 HXR 355LC6 303 1189 94.8 94.8 0.81 0.78 85 536 F 34 1546 95 198 4101 80
350 900 HXR 400LC8 412 891 94.8 94.9 0.81 0.78 85 478 E 33 2063 82 186 5600 75
350 720 HXR 400LF10 501 714 94.3 94.1 0.72 0.66 96 469 F 51 2575 87 186 6460 79
350 600 HXR 450LF12 588 595 94.4 94.1 0.69 0.63 100 413 E 54 3092 75 175 8576 75
400 3600 HXR 355LC2 80 3571 94.6 94.5 0.92 0.91 86 656 G 20 588 68 266 4079 89
400 1800 HXR 355LC4 189 1786 95.0 94.9 0.86 0.83 92 647 G 31 1175 102 224 4034 82
400 1200 HXR 355LD6 304 1189 95.0 95.0 0.81 0.78 97 531 F 38 1765 95 194 4211 80
400 900 HXR 400LC8 413 891 94.8 95.0 0.81 0.78 97 478 E 37 2356 83 183 5710 75
400 720 HXR 400LH10 502 714 94.3 93.9 0.72 0.66 111 476 F 59 2939 87 190 7121 80
400 600 HXR 450LG12 589 594 94.5 94.3 0.70 0.64 113 410 E 60 3531 75 171 8951 75
450 3600 HXR 355LD2 81 3571 94.9 94.8 0.92 0.90 97 636 F 22 663 65 258 4189 89
450 1800 HXR 355LD4 190 1786 95.2 95.1 0.86 0.84 103 626 G 33 1325 99 214 4233 82
450 1200 HXR 355LE6 305 1189 95.1 95.2 0.82 0.78 108 541 F 41 1990 98 191 4497 80
450 900 HXR 400LE8 414 892 95.1 95.2 0.81 0.77 110 518 F 45 2653 90 199 6283 75
450 720 HXR 400LK10 503 714 94.4 94.1 0.72 0.66 124 490 F 65 3313 93 195 7562 80
450 600 HXR 450LH12 590 594 94.6 94.4 0.70 0.65 126 407 E 66 3981 74 168 9480 75
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
88 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Cast iron motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEFC – Insulation class F, temperature rise class B, S.F. 1.0
IEC frame size NEMA frame size
355 58xx
400 68xx
450 72xx
500 80xx
560 88xx
2300 V 60 Hz500 3600 HXR 355LD2 82 3577 95.1 94.9 0.90 0.88 110 692 G 30 734 63 285 4277 89
500 1800 HXR 355LE4 191 1786 95.3 95.3 0.87 0.84 113 632 G 35 1471 101 213 4453 82
500 1200 HXR 355LF6 306 1189 95.3 95.3 0.82 0.79 120 551 F 46 2209 101 195 4718 80
500 900 HXR 400LG8 415 892 95.3 95.4 0.81 0.77 121 529 F 49 2944 93 202 6702 75
500 720 HXR 450LF10 504 714 95.5 95.6 0.76 0.70 130 493 F 62 3678 86 192 8554 76
500 600 HXR 450LK12 591 595 94.7 94.5 0.71 0.65 139 407 E 72 4419 73 168 10207 75
600 3600 HXR 400LE2 83 3579 95.3 95.1 0.92 0.91 128 697 G 28 882 69 273 6107 88
600 1800 HXR 400LC4 192 1789 95.7 95.6 0.87 0.84 135 635 G 43 1763 90 220 5842 80
600 1200 HXR 400LE6 307 1191 95.5 95.5 0.83 0.80 141 575 F 52 2649 87 202 6305 79
600 900 HXR 400LH8 416 892 95.2 95.3 0.82 0.78 145 523 F 57 3537 93 197 7143 78
600 720 HXR 450LH10 505 714 95.7 95.8 0.76 0.72 154 488 E 71 4419 85 188 9259 76
600 600 HXR 500LH12 592 595 95.0 94.8 0.70 0.65 168 431 E 88 5304 76 176 12919 75
700 3600 HXR 400LF2 84 3578 95.6 95.5 0.93 0.92 148 663 F 30 1028 66 259 6504 88
700 1800 HXR 400LD4 193 1789 95.9 95.9 0.87 0.85 156 629 F 47 2055 91 213 6129 80
700 1200 HXR 400LG6 308 1191 95.7 95.7 0.84 0.81 163 589 F 57 3087 94 202 6724 79
700 900 HXR 450LG8 418 894 95.7 95.7 0.82 0.78 167 588 F 67 4112 90 219 9083 76
700 720 HXR 450LK10 506 714 95.8 95.9 0.76 0.71 180 515 F 85 5146 92 198 10119 76
700 600 HXR 500LK12 593 595 95.1 94.9 0.71 0.65 195 437 E 102 6179 78 179 13801 75
800 3600 HXR 400LH2 85 3583 95.8 95.7 0.92 0.90 171 718 G 40 1174 63 282 6878 88
800 1800 HXR 400LF4 194 1789 96.1 96.1 0.88 0.87 177 624 F 48 2351 95 208 6702 80
800 1200 HXR 400LJ6 309 1191 95.8 95.9 0.85 0.82 184 569 F 60 3531 91 195 7430 79
800 900 HXR 450LJ8 419 894 95.9 95.8 0.81 0.77 192 602 G 81 4701 90 225 9789 76
800 720 HXR 450LM10 507 715 95.7 95.8 0.76 0.71 206 522 F 98 5884 94 200 10825 78
800 600 HXR 500LL12 594 595 95.0 94.9 0.71 0.66 222 427 E 114 7069 77 173 14242 75
900 3600 HXR 450LH2 86 3585 95.7 95.4 0.91 0.89 194 726 G 52 1318 57 290 9370 91
900 1800 HXR 400LH4 195 1789 96.3 96.3 0.88 0.87 198 638 F 53 2641 99 207 7187 80
900 1200 HXR 450LE6 310 1192 96.1 96.2 0.88 0.86 200 555 E 54 3965 83 191 8466 80
900 900 HXR 450LL8 420 895 96.1 96.0 0.81 0.77 215 590 G 87 5279 91 211 10516 76
900 720 HXR 500LJ10 508 715 96.1 96.2 0.78 0.74 225 488 E 97 6613 76 188 13360 78
900 600 HXR 500LN12 595 595 95.1 94.9 0.71 0.66 249 433 E 128 7944 78 175 15080 75
1000 3600 HXR 500LJ2 87 3585 95.4 95.0 0.92 0.91 213 712 G 52 1466 56 296 13360 91
1000 1800 HXR 450LG4 196 1790 96.2 96.2 0.89 0.87 219 648 G 60 2935 91 221 9215 82
1000 1200 HXR 450LJ6 311 1193 96.3 96.4 0.88 0.86 221 610 F 62 4404 93 208 9722 80
1000 900 HXR 450LN8 421 895 96.1 96.1 0.82 0.78 238 592 G 96 5868 91 211 11244 76
1000 720 HXR 500LL10 509 715 96.1 96.3 0.79 0.75 248 480 E 104 7354 75 184 14021 78
1000 600 HXR 500LQ12 596 595 95.2 95.1 0.72 0.67 273 416 E 134 8837 74 167 15719 75
2300 V 60 Hz
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 89
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Cast iron motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEFC – Insulation class F, temperature rise class B, S.F. 1.0
2300 V 60 Hz
IEC frame size NEMA frame size
355 58xx
400 68xx
450 72xx
500 80xx
560 88xx
2300 V 60 Hz1250 3600 HXR 500LM2 88 3586 95.8 95.6 0.92 0.91 265 709 G 61 1831 57 279 14617 91
1250 1800 HXR 450LL4 197 1791 96.5 96.5 0.89 0.87 272 675 G 73 3665 98 224 10648 82
1250 1200 HXR 500LG6 312 1194 96.3 96.4 0.86 0.84 281 613 F 90 5498 82 218 12588 82
1250 900 HXR 500LM8 422 895 96.2 96.2 0.83 0.79 293 611 G 114 7336 86 221 14617 77
1250 720 HXR 500LP10 510 715 96.1 96.2 0.79 0.75 309 483 E 127 9187 77 183 15543 80
1250 600 HXR 560LM12 685 596 96.0 96.0 0.76 0.71 319 466 E 150 11025 66 195 21495 77
1500 3600 HXR 500LQ2 89 3587 96.1 95.9 0.91 0.89 321 727 G 82 2197 54 277 15829 91
1500 1800 HXR 500LJ4 198 1792 96.5 96.6 0.90 0.88 324 676 G 86 4398 83 241 13580 82
1500 1200 HXR 500LK6 313 1194 96.6 96.7 0.87 0.85 332 642 G 102 6599 83 225 13580 82
1500 900 HXR 500LS8 423 896 96.4 96.4 0.83 0.80 349 590 F 129 8799 85 210 17042 77
1500 720 HXR 500LS10 511 715 96.1 96.2 0.79 0.74 371 508 F 159 11018 75 189 17086 80
1500 600 HXR 560LR12 686 596 96.1 96.0 0.76 0.70 387 494 F 192 13215 72 208 23656 77
1750 900 HXR 560LM8 679 896 96.7 96.8 0.82 0.79 411 570 F 159 10258 72 209 21627 80
1750 720 HXR 560LP10 683 717 96.4 96.4 0.78 0.73 438 510 F 194 12827 69 187 22774 81
1750 600 HXR 560LU12 687 597 96.3 96.3 0.77 0.73 442 452 E 195 15402 64 180 26698 77
1750 1800 HXR 500LM4 199 1792 96.7 96.8 0.90 0.89 375 640 F 90 5134 80 225 14881 82
1750 1200 HXR 500LM6 314 1195 96.7 96.8 0.87 0.85 388 656 G 122 7699 84 229 14661 82
2000 900 HXR 560LP8 680 897 96.9 96.9 0.81 0.77 475 603 G 191 11710 79 206 22774 80
2000 720 HXR 560LT10 684 717 96.5 96.4 0.78 0.73 499 541 F 225 14649 74 200 26015 81
2000 1800 HXR 500LP4 200 1792 96.8 96.9 0.90 0.89 429 666 G 105 5864 84 229 15675 82
2000 1200 HXR 500LQ6 315 1194 96.8 97.0 0.88 0.86 439 627 F 124 8799 83 216 15984 82
2250 1800 HXR 560LK4 674 1793 96.8 96.9 0.90 0.89 481 670 G 123 6590 68 245 20723 85
2250 1200 HXR 500LS6 316 1196 96.9 97.0 0.86 0.83 506 690 G 171 9881 88 226 17350 82
2250 900 HXR 560LS8 681 897 96.9 97.0 0.82 0.78 531 608 G 207 13177 80 208 25552 80
2500 1800 HXR 560LM4 675 1794 96.9 97.0 0.90 0.88 538 704 G 149 7318 69 254 21826 85
2500 1200 HXR 560LR6 677 1195 96.9 97.0 0.88 0.85 550 668 G 168 10983 79 235 23920 85
2500 900 HXR 560LU8 682 897 97.0 97.1 0.83 0.79 582 609 G 229 14637 66 225 27514 80
3000 1800 HXR 560LT4 676 1794 97.5 97.5 0.91 0.90 632 691 G 143 8780 77 229 26301 85
3000 1200 HXR 560LU6 678 1196 97.4 97.5 0.88 0.87 652 612 F 167 13178 76 199 27249 85
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
90 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Cast iron motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEFC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
355 58xx
400 68xx
450 72xx
500 80xx
560 88xx
4000 V 60 Hz150 3600 HXR 355LA2 8662 3559 91.9 91.1 0.90 0.89 19 5 556 E 222 58 256 3527 89
150 1800 HXR 355LA4 8670 1787 93.0 92.2 0.82 0.78 21 9 561 F 441 71 238 3638 82
150 1200 HXR 355LA6 8684 1188 93.0 92.5 0.79 0.74 22 10 493 F 664 68 225 3616 80
200 3600 HXR 355LA2 92 3572 92.5 91.7 0.89 0.87 26 7 615 F 294 66 258 3505 89
200 1800 HXR 355LA4 203 1787 93.1 92.4 0.82 0.77 28 12 650 H 587 100 246 3417 82
200 1200 HXR 355LA6 318 1189 93.3 92.9 0.79 0.74 29 13 523 F 883 98 203 3616 80
200 900 HXR 400LA8 424 890 93.7 93.7 0.77 0.73 30 13 437 D 1179 79 178 5093 75
200 600 HXR 400LD12 598 594 92.8 92.5 0.68 0.62 34 19 408 E 1767 84 176 5908 75
250 3600 HXR 355LA2 93 3568 93.0 92.5 0.90 0.88 32 9 634 G 367 67 268 3417 89
250 1800 HXR 355LA4 204 1785 93.5 93.1 0.83 0.79 35 14 621 G 734 98 239 3439 82
250 1200 HXR 355LA6 319 1187 93.7 93.5 0.79 0.75 36 15 517 F 1103 103 190 3594 80
250 900 HXR 400LB8 425 890 94.1 94.2 0.78 0.74 37 16 430 D 1472 79 172 5357 75
250 720 HXR 400LD10 512 714 93.5 93.1 0.71 0.64 41 23 485 F 1834 90 200 5776 79
250 600 HXR 400LF12 599 594 93.1 92.9 0.69 0.63 42 23 405 E 2206 84 172 6327 75
300 3600 HXR 355LA2 94 3573 93.7 93.4 0.90 0.88 38 10 645 G 442 70 260 3616 89
300 1800 HXR 355LA4 205 1783 93.8 93.6 0.84 0.81 41 15 568 F 885 91 214 3439 82
300 1200 HXR 355LB6 320 1187 94.1 94.0 0.80 0.76 43 18 516 F 1329 104 185 3814 80
300 900 HXR 400LD8 426 890 94.4 94.5 0.78 0.74 44 19 445 D 1772 83 176 5776 75
300 720 HXR 400LD10 513 714 93.5 93.2 0.72 0.66 48 26 464 F 2210 86 185 5908 80
300 600 HXR 400LH12 600 594 93.5 93.2 0.69 0.62 50 28 418 E 2656 87 177 7033 75
350 3600 HXR 355LB2 95 3571 94.1 93.9 0.91 0.90 44 10 600 F 515 66 236 3814 89
350 1800 HXR 355LA4 206 1786 94.4 94.2 0.85 0.81 47 17 638 G 1029 99 230 3638 82
350 1200 HXR 355LC6 321 1190 94.6 94.5 0.80 0.76 50 21 525 F 1545 89 199 4057 80
350 900 HXR 400LE8 427 890 94.6 94.8 0.79 0.75 51 21 434 D 2065 81 170 6063 75
350 720 HXR 400LF10 514 714 93.8 93.5 0.72 0.65 56 30 485 F 2574 91 193 6482 80
350 600 HXR 450LG12 601 595 94.2 93.9 0.69 0.63 58 32 425 E 3090 77 182 8841 75
400 3600 HXR 355LC2 96 3570 94.4 94.3 0.90 0.89 50 12 614 F 588 64 241 4034 89
400 1800 HXR 355LB4 207 1786 94.7 94.6 0.85 0.82 54 19 639 G 1175 100 228 3748 82
400 1200 HXR 355LD6 322 1189 94.8 94.8 0.81 0.78 56 22 538 F 1765 95 198 4255 80
400 900 HXR 400LG8 428 891 94.8 94.9 0.79 0.75 58 24 467 E 2356 89 181 6570 75
400 720 HXR 400LH10 515 714 94.0 93.8 0.73 0.67 63 33 475 F 2940 89 188 6900 80
400 600 HXR 450LH12 602 595 94.3 94.0 0.70 0.63 65 36 426 E 3528 77 180 9370 75
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 91
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Cast iron motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEFC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
355 58xx
400 68xx
450 72xx
500 80xx
560 88xx
4000 V 60 Hz450 3600 HXR 355LD2 97 3573 94.8 94.7 0.92 0.90 56 13 654 G 662 66 261 4233 89
450 1800 HXR 355LC4 208 1788 95.0 94.9 0.85 0.82 60 21 622 G 1324 99 207 3990 82
450 1200 HXR 355LE6 323 1190 95.0 95.0 0.82 0.78 63 25 544 F 1989 97 198 4475 80
450 900 HXR 400LH8 429 890 95.0 95.1 0.79 0.76 65 26 446 D 2658 85 172 6900 75
450 720 HXR 400LK10 516 714 94.2 94.0 0.73 0.68 70 36 471 F 3315 87 184 7452 80
450 600 HXR 450LK12 603 595 94.5 94.2 0.70 0.63 74 41 435 E 3977 79 184 10075 75
500 3600 HXR 400LD2 98 3581 94.9 94.5 0.90 0.89 63 16 696 G 734 61 276 5886 88
500 1800 HXR 355LD4 209 1788 95.2 95.2 0.85 0.82 66 23 637 G 1469 103 208 4189 82
500 1200 HXR 400LD6 324 1191 95.4 95.4 0.83 0.79 68 26 572 F 2206 89 210 5975 79
500 900 HXR 400LH8 430 891 94.7 94.8 0.79 0.75 72 29 451 D 2950 87 173 6989 78
500 720 HXR 450LF10 517 714 95.2 95.3 0.76 0.71 74 35 486 E 3679 84 187 8554 76
500 600 HXR 450LN12 604 595 94.6 94.2 0.69 0.63 82 46 448 F 4413 82 191 11133 75
600 3600 HXR 400LE2 99 3581 95.3 95.0 0.91 0.89 75 19 701 G 881 64 269 6173 88
600 1800 HXR 400LC4 210 1790 95.7 95.6 0.88 0.85 77 24 626 F 1763 81 223 5820 80
600 1200 HXR 400LE6 325 1191 95.5 95.6 0.83 0.80 81 30 560 F 2650 88 202 6217 79
600 900 HXR 450LE8 431 893 95.3 95.3 0.83 0.80 82 31 550 F 3533 87 213 8289 76
600 720 HXR 450LH10 518 714 95.4 95.5 0.76 0.71 89 43 508 F 4417 90 196 9281 76
600 600 HXR 500LJ12 605 595 94.6 94.4 0.71 0.66 96 49 423 E 5307 77 170 13250 75
700 3600 HXR 400LG2 100 3582 95.6 95.4 0.91 0.89 87 21 707 G 1026 65 265 6548 88
700 1800 HXR 400LE4 211 1790 95.9 95.9 0.88 0.87 89 25 639 F 2054 88 220 6217 80
700 1200 HXR 400LH6 326 1192 95.8 95.8 0.83 0.79 95 36 595 F 3086 94 213 6923 79
700 900 HXR 450LG8 432 893 95.2 95.2 0.83 0.80 95 35 556 F 4116 89 213 8995 82
700 720 HXR 450LK10 519 714 95.4 95.5 0.77 0.72 103 47 494 F 5148 87 189 9811 78
700 600 HXR 500LM12 606 595 94.6 94.3 0.71 0.66 112 58 438 E 6181 81 175 14330 75
800 3600 HXR 450LG2 101 3584 95.4 95.1 0.91 0.90 99 24 705 G 1173 64 278 8929 91
800 1800 HXR 400LF4 212 1790 96.0 96.1 0.89 0.87 101 28 639 F 2349 87 217 6570 80
800 1200 HXR 450LE6 327 1192 95.9 96.1 0.88 0.86 102 29 575 F 3527 85 200 8378 80
800 900 HXR 450LH8 433 893 95.4 95.4 0.84 0.81 108 38 543 F 4708 87 201 9348 82
800 720 HXR 450LM10 520 714 95.5 95.6 0.77 0.73 117 53 491 E 5888 87 186 10516 78
800 600 HXR 500LP12 607 595 94.7 94.5 0.72 0.67 126 62 422 E 7073 77 168 15190 75
900 3600 HXR 450LK2 102 3582 95.6 95.4 0.93 0.92 109 23 687 G 1319 60 275 9766 91
900 1800 HXR 400LH4 213 1791 96.2 96.2 0.88 0.85 115 34 641 G 2639 82 219 7011 80
900 1200 HXR 450LG6 328 1193 96.1 96.2 0.87 0.85 115 35 622 F 3961 92 214 9039 80
900 900 HXR 450LM8 434 894 95.6 95.5 0.84 0.81 120 43 575 F 5289 94 218 10759 82
900 720 HXR 500LL10 521 715 95.9 96.0 0.78 0.74 129 55 490 E 6613 77 188 13911 78
900 600 HXR 500LR12 608 595 94.8 94.6 0.72 0.67 141 69 424 E 7949 78 168 16072 75
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
92 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Reg. Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)
HV Cast iron motors, engineeredTechnical data for totally enclosed squirrel cage three phase motors TEFC – Insulation class F, temperature rise class B, S.F. 1.0
4000 V 60 Hz
IEC frame size NEMA frame size
355 58xx
400 68xx
450 72xx
500 80xx
560 88xx
4000 V 60 Hz1000 3600 HXR 500LH2 103 3588 95.4 95.0 0.91 0.89 124 32 725 G 1464 56 289 12831 91
1000 1800 HXR 450LH4 214 1791 96.2 96.2 0.89 0.88 125 33 637 F 2933 80 224 9480 82
1000 1200 HXR 450LJ6 329 1193 96.2 96.3 0.88 0.86 127 36 612 F 4404 91 210 9744 80
1000 900 HXR 500LL8 435 895 96.1 96.1 0.83 0.80 134 50 575 F 5868 82 207 13955 77
1000 720 HXR 500LN10 522 715 96.0 96.0 0.79 0.74 143 62 505 E 7350 81 193 14991 78
1000 600 HXR 560LJ12 701 596 95.7 95.7 0.76 0.71 148 72 470 E 8815 66 198 19599 77
1250 3600 HXR 500LM2 104 3587 95.9 95.6 0.93 0.92 151 33 710 G 1830 60 279 14462 91
1250 1800 HXR 450LL4 215 1791 96.4 96.5 0.89 0.88 156 40 646 F 3664 83 221 10362 82
1250 1200 HXR 500LG6 330 1194 96.3 96.3 0.86 0.83 162 53 612 F 5498 82 217 12434 82
1250 900 HXR 500LN8 436 896 96.2 96.2 0.83 0.80 168 63 588 F 7330 86 208 14947 77
1250 720 HXR 500LR10 523 715 95.8 95.9 0.79 0.76 177 72 484 E 9187 78 183 16204 80
1250 600 HXR 560LN12 702 597 95.9 95.9 0.76 0.71 185 86 460 E 11011 66 185 21693 77
1500 3600 HXR 500LQ2 105 3589 96.2 95.9 0.91 0.90 184 44 741 G 2196 60 278 15454 91
1500 1800 HXR 500LJ4 216 1792 96.4 96.5 0.89 0.88 187 50 646 F 4399 77 232 13140 82
1500 1200 HXR 500LK6 331 1194 96.4 96.5 0.87 0.85 193 59 615 F 6602 85 213 13735 82
1500 900 HXR 500LS8 437 896 96.4 96.3 0.83 0.80 202 76 603 G 8798 88 214 17108 77
1500 720 HXR 560LM10 698 715 96.0 96.1 0.79 0.75 213 89 486 E 11020 69 183 21363 81
1500 600 HXR 560LS12 703 597 96.2 96.1 0.77 0.72 219 100 469 E 13204 67 188 25045 77
1750 900 HXR 560LM8 695 896 96.6 96.7 0.82 0.79 237 92 571 F 10258 72 209 21451 80
1750 720 HXR 560LR10 699 717 96.3 96.3 0.78 0.74 251 111 521 F 12824 70 193 24097 81
1750 1800 HXR 500LL4 217 1792 96.6 96.7 0.90 0.88 217 56 637 F 5134 77 226 14286 82
1750 1200 HXR 500LP6 332 1194 96.6 96.7 0.87 0.84 225 69 613 F 7702 83 213 15454 82
2000 1200 HXR 560LK6 691 1195 96.7 96.7 0.87 0.85 255 81 663 G 8786 78 235 20437 85
2000 900 HXR 560LR8 696 896 96.8 96.8 0.82 0.79 270 104 570 F 11718 72 210 23634 80
2000 720 HXR 560LU10 700 717 96.4 96.4 0.78 0.74 285 126 536 F 14649 72 199 27117 81
2000 1800 HXR 500LR4 218 1793 96.8 96.8 0.89 0.87 250 69 641 F 5861 72 228 16424 82
2250 1800 HXR 560LK4 688 1794 96.8 96.8 0.90 0.89 277 73 689 G 6589 70 251 20613 85
2250 1200 HXR 560LP6 692 1196 96.8 96.8 0.87 0.84 288 95 670 G 9885 75 240 22355 85
2250 900 HXR 560LU8 697 896 96.9 96.9 0.83 0.79 303 120 614 G 13184 80 225 26940 80
2500 1800 HXR 560LS4 689 1793 96.9 97.0 0.91 0.90 304 68 653 F 7322 70 236 24978 85
2500 1200 HXR 560LS6 693 1196 96.9 97.0 0.88 0.86 316 97 676 G 10981 80 239 25287 85
3000 1800 HXR 560LT4 690 1795 97.4 97.4 0.90 0.88 369 98 711 G 8776 70 236 25948 85
3000 1200 HXR 560LU6 694 1196 97.3 97.3 0.87 0.85 381 119 681 G 13168 78 223 26985 85
Data presented in rating lists are typical values. Guaranteed values on request. All engineered motors are optimized for the specific application. Accurate motor data will be given on request at quotation phase. Legally binding performance and specification data is given to the end user once each order is confirmed.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 93
3
HV Modular induction motors, engineeredDimension drawings Antifriction bearings, 2300 < U ≤ 6900 V, F1/F2, WPII
Motor type
Poles 2E 2F BA N-W H G U F R SR D C O FP
IEC NEMA
AMA 400L 68xx 2 29.53 49.21 7.87 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 73.62 67.3 63.8
AMA 400L 68xx ≥ 4 29.53 49.21 7.87 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 75.20 67.3 63.8
AMA 450L 72xx 2 33.47 55.12 7.87 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 79.53 73.2 67.7
AMA 450L 72xx ≥ 4 33.47 55.12 7.87 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 81.10 73.2 67.7
AMA 500L 80xx ≥ 4 37.40 62.99 7.87 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 90.55 81.1 71.7
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
Motor type
Poles A B K FK J AB AC AE AF FDS BS
IEC NEMA
AMA 400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 400L 68xx ≥ 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 450L 72xx ≥ 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 500L 80xx ≥ 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
Motor type
Poles D-end bearing N-end bearing
IEC NEMA
AMA 400L 68xx 2 6319M/C3 6319M/C3
AMA 400L 68xx ≥ 4 6324/C3 6319/C3
AMA 450L 72xx 2 6319M/C3 6319M/C3
AMA 450L 72xx ≥ 4 6326/C3 6322/C3
AMA 500L 80xx ≥ 4 6330/C3 6324/C3
94 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
HV Modular induction motors, engineeredDimension drawings Sleeve bearings, 2300 < U ≤ 6900 V, F1/F2, WPII
Motor type
Poles 2E 2F BA N-W H G U F R SR D C O FP
IEC NEMA
AMA 400L 68xx 2 29.53 49.21 14.76 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 81.30 67.3 63.8
AMA 400L 68xx ≥ 4 29.53 49.21 14.76 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 82.68 67.3 63.8
AMA 450L 72xx 2 33.47 55.12 14.76 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 87.21 73.2 67.7
AMA 450L 72xx ≥ 4 33.47 55.12 15.75 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 89.57 73.2 67.7
AMA 500L 80xx 2 37.40 62.99 14.76 8.268 1.65 1.38 4.331 1.102 3.937 0.630 19.69 97.84 81.1 71.7
AMA 500L 80xx ≥ 4 37.40 62.99 17.72 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 102.17 81.1 71.7
Motor type
Poles A B K FK J AB AC AE AF FDS BS
IEC NEMA
AMA 400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 400L 68xx ≥ 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 450L 72xx ≥ 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 500L 80xx 2 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
AMA 500L 80xx 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
AMA 500L 80xx ≥ 6 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
Motor type
Poles D-end bearing N-end bearing
IEC NEMA
AMA 400L 68xx 2 EFZLB9-80 EFZLQ9-80
AMA 400L 68xx ≥ 4 EFZLB9-100 EFZLQ9-100
AMA 450L 72xx 2 EFZLB9-80 EFZLQ9-80
AMA 450L 72xx ≥ 4 EFZLB11-125 EFZLQ9-100
AMA 500L 80xx 2 EFNLB11-90 EFNLB11-90
AMA 500L 80xx 4 EFZLB14-125 EFZLQ11-125
AMA 500L 80xx ≥ 6 EFZLB14-140 EFZLQ11-125
Note! Includes provision for BN proximity probes. Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 95
3
HV Modular induction motors, engineeredDimension drawings Antifriction bearings, 2300 < U ≤ 6900 V, F1/F2, TEAAC
Motor type
Poles 2E 2F BA N-W H G U F R SR D C O FP
IEC NEMA
AMA 400L 68xx 2 29.53 49.21 7.87 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 90.16 62.6 63.8
AMA 400L 68xx ≥ 4 29.53 49.21 7.87 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 91.73 62.6 63.8
AMA 450L 72xx 2 33.47 55.12 7.87 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 97.64 69.3 67.7
AMA 450L 72xx ≥ 4 33.47 55.12 7.87 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 99.21 69.3 67.7
AMA 500L 80xx ≥ 4 37.40 62.99 7.87 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 111.42 77.2 71.7
Motor type
Poles A B K FK J AB AC AE AF FDS BS
IEC NEMA
AMA 400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 400L 68xx ≥ 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 450L 72xx ≥ 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 500L 80xx ≥ 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
Motor type
Poles D-end bearing N-end bearing
IEC NEMA
AMA 400L 68xx 2 6319M/C3 6319M/C3
AMA 400L 68xx ≥ 4 6324/C3 6319/C3
AMA 450L 72xx 2 6319M/C3 6319M/C3
AMA 450L 72xx ≥ 4 6326/C3 6322/C3
AMA 500L 80xx ≥ 4 6330/C3 6324/C3
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
96 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
HV Modular induction motors, engineeredDimension drawings Sleeve bearings, 2300 < U ≤ 6900 V, F1/F2, TEAAC
Motor type
Poles 2E 2F BA N-W H G U F R SR D C O FP
IEC NEMA
AMA 400L 68xx 2 29.53 49.21 14.76 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 97.05 62.6 63.8
AMA 400L 68xx ≥ 4 29.53 49.21 14.76 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 98.62 62.6 63.8
AMA 450L 72xx 2 33.47 55.12 14.76 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 104.53 69.3 67.7
AMA 450L 72xx ≥ 4 33.47 55.12 15.75 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 107.09 69.3 67.7
AMA 500L 80xx 2 37.40 62.99 14.76 8.268 1.65 1.38 4.331 1.102 3.937 0.630 19.69 116.73 77.2 71.7
AMA 500L 80xx ≥ 4 37.40 62.99 17.72 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 121.26 77.2 71.7
Motor type
Poles A B K FK J AB AC AE AF FDS BS
IEC NEMA
AMA 400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 400L 68xx ≥ 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 450L 72xx ≥ 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 500L 80xx 2 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
AMA 500L 80xx 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
AMA 500L 80xx ≥ 6 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
Motor type
Poles D-end bearing N-end bearing
IEC NEMA
AMA 400L 68xx 2 EFZLB9-80 EFZLQ9-80
AMA 400L 68xx ≥ 4 EFZLB9-100 EFZLQ9-100
AMA 450L 72xx 2 EFZLB9-80 EFZLQ9-80
AMA 450L 72xx ≥ 4 EFZLB11-125 EFZLQ9-100
AMA 500L 80xx 2 EFNLB11-90 EFNLB11-90
AMA 500L 80xx 4 EFZLB14-125 EFZLQ11-125
AMA 500L 80xx ≥ 6 EFZLB14-140 EFZLQ11-125
Note! Includes provision for BN proximity probes. Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 97
3
HV Modular induction motors, engineeredDimension drawings Antifriction bearings, 2300 < U ≤ 6900 V, F1/F2, TEWAC
Motor type
Poles 2E 2F BA N-W H G U F R SR D C O FP
IEC NEMA
AMA 400L 68xx 2 29.53 49.21 7.87 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 73.62 65.7 63.8
AMA 400L 68xx ≥ 4 29.53 49.21 7.87 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 75.20 65.7 63.8
AMA 450L 72xx 2 33.47 55.12 7.87 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 79.53 73.6 67.7
AMA 450L 72xx ≥ 4 33.47 55.12 7.87 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 81.10 73.6 67.7
AMA 500L 80xx ≥ 4 37.40 62.99 7.87 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 90.55 81.5 71.7
Motor type
Poles A B K FK J AB AC AE AF FDS BS
IEC NEMA
AMA 400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 400L 68xx ≥ 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 450L 72xx ≥ 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 500L 80xx ≥ 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
Motor type
Poles D-end bearing N-end bearing
IEC NEMA
AMA 400L 68xx 2 6319M/C3 6319M/C3
AMA 400L 68xx ≥ 4 6324/C3 6319/C3
AMA 450L 72xx 2 6319M/C3 6319M/C3
AMA 450L 72xx ≥ 4 6326/C3 6322/C3
AMA 500L 80xx ≥ 4 6330/C3 6324/C3
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
98 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
HV Modular induction motors, engineeredDimension drawings Sleeve bearings, 2300 < U ≤ 6900 V, F1/F2, TEWAC
Motor type
Poles 2E 2F BA N-W H G U F R SR D C O FP
IEC NEMA
AMA 400L 68xx 2 29.53 49.21 14.76 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 81.30 65.7 63.8
AMA 400L 68xx ≥ 4 29.53 49.21 14.76 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 82.68 65.7 63.8
AMA 450L 72xx 2 33.47 55.12 14.76 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 87.21 73.6 67.7
AMA 450L 72xx ≥ 4 33.47 55.12 15.75 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 89.57 73.6 67.7
AMA 500L 80xx 2 37.40 62.99 14.76 8.268 1.65 1.38 4.331 1.102 3.937 0.630 19.69 97.84 81.5 71.7
AMA 500L 80xx ≥ 4 37.40 62.99 17.72 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 102.17 81.5 71.7
Motor type
Poles A B K FK J AB AC AE AF FDS BS
IEC NEMA
AMA 400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 400L 68xx ≥ 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
AMA 450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 450L 72xx ≥ 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
AMA 500L 80xx 2 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
AMA 500L 80xx 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
AMA 500L 80xx ≥ 6 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
Motor type
Poles D-end bearing N-end bearing
IEC NEMA
AMA 400L 68xx 2 EFZLB9-80 EFZLQ9-80
AMA 400L 68xx ≥ 4 EFZLB9-100 EFZLQ9-100
AMA 450L 72xx 2 EFZLB9-80 EFZLQ9-80
AMA 450L 72xx ≥ 4 EFZLB11-125 EFZLQ9-100
AMA 500L 80xx 2 EFNLB11-90 EFNLB11-90
AMA 500L 80xx 4 EFZLB14-125 EFZLQ11-125
AMA 500L 80xx ≥ 6 EFZLB14-140 EFZLQ11-125
Note! Includes provision for BN proximity probes. Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 99
3
Motor type
Poles AB AC AD AF AJ AK BB BD BE BF BV C
IEC NEMA
AMA 400L 68xx ≥ 4 42.2 34.1 1.97 18.4 42.52 39.37 0.236 44.49 1.181 1.102 49.0 75.4
AMA 450L 72xx ≥ 4 44.2 36.0 1.97 18.4 46.46 44.09 0.276 48.43 1.575 1.102 54.9 81.3
AMA 500L 80xx ≥ 4 46.2 38.0 1.97 18.4 51.97 49.21 0.315 53.94 1.850 1.102 62.8 90.7
Motor type
Poles FDS N-W P R S T U U-R D-end bearing N-end bearing
IEC NEMA
AMA 400L 68xx ≥ 4 17.5 8.268 73.8 3.937 1.102 3.15 4.331 0.630 6324/C3 7319B
AMA 450L 72xx ≥ 4 21.3 8.268 79.7 4.488 1.260 3.15 4.921 0.709 6326/C3 7322B
AMA 500L 80xx ≥ 4 24.0 9.843 88.4 5.039 1.417 3.15 5.512 0.787 6330/C3 7324B
HV Modular induction motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, WPII, vertical
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
100 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
Motor type
Poles AB AC AD AF AJ AK BB BD BE BF BV C
IEC NEMA
AMA 400L 68xx ≥ 4 42.2 34.1 1.97 18.4 42.52 39.37 0.236 44.49 1.181 1.102 49.0 91.7
AMA 450L 72xx ≥ 4 44.2 36.0 1.97 18.4 46.46 44.09 0.276 48.43 1.575 1.102 54.9 99.2
AMA 500L 80xx ≥ 4 46.2 38.0 1.97 18.4 51.97 49.21 0.315 53.94 1.850 1.102 62.8 111.4
Motor type
Poles FDS N-W P R S U U-R D-end bearing N-end bearing
IEC NEMA
AMA 400L 68xx ≥ 4 17.5 8.268 69.3 3.937 1.102 4.331 0.630 6324/C3 7319B
AMA 450L 72xx ≥ 4 21.3 8.268 76.0 4.488 1.260 4.921 0.709 6326/C3 7322B
AMA 500L 80xx ≥ 4 24.0 9.843 84.6 5.039 1.417 5.512 0.787 6330/C3 7324B
HV Modular induction motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEAAC, vertical
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 101
3
Motor type
Poles AB AC AD AF AJ AK BB BD BE BF BV C
IEC NEMA
AMA 400L 68xx ≥ 4 42.2 34.1 1.97 18.4 42.52 39.37 0.236 44.49 1.181 1.102 49.0 91.8
AMA 450L 72xx ≥ 4 44.2 36.0 1.97 18.4 46.46 44.09 0.276 48.43 1.575 1.102 54.9 81.3
AMA 500L 80xx ≥ 4 46.2 38.0 1.97 18.4 51.97 49.21 0.315 53.94 1.850 1.102 62.8 90.7
Motor type
Poles FDS N-W P R S T U U-R D-end bearing N-end bearing
IEC NEMA
AMA 400L 68xx ≥ 4 17.5 8.268 72.3 3.937 1.102 3.15 4.331 0.630 6324/C3 7319B
AMA 450L 72xx ≥ 4 21.3 8.268 80.0 4.488 1.260 3.15 4.921 0.709 6326/C3 7322B
AMA 500L 80xx ≥ 4 24.0 9.843 89.0 5.039 1.417 3.15 5.512 0.787 6330/C3 7324B
HV Modular induction motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEWAC, vertical
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
102 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
HV Cast iron motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEFC, F1
Motor type
Poles 2E 2F BA U N-W F D FP O C H FDS BS
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 10.00 2.750 5.500 0.625 14.50 54.9 57.1 59.5 1.38 27.6 0.7
HXR 355L 58xx ≥ 4 25.00 25.00 10.00 4.000 8.250 1.000 14.50 54.9 57.1 65.7 1.38 27.6 0.7
HXR 400L 68xx 2 28.00 36.00 9.00 3.125 6.500 0.750 17.00 54.9 61.3 69.1 1.38 35.2 1.3
HXR 400L 68xx ≥ 4 28.00 36.00 9.00 4.375 8.250 1.000 17.00 54.9 61.3 74.6 1.38 35.2 1.3
HXR 450L 72xx 2 32.00 40.00 10.00 3.125 6.500 0.750 18.00 61.8 64.3 78.0 1.65 42.3 0.8
HXR 450L 72xx ≥ 4 32.00 40.00 10.00 4.375 8.250 1.000 18.00 61.8 64.3 83.5 1.65 42.3 0.8
HXR 500L 80xx 2 36.00 50.00 11.00 3.500 6.500 0.875 20.00 61.8 69.3 91.1 1.65 52.8 0.4
HXR 500L 80xx ≥ 4 36.00 50.00 11.00 4.750 8.250 1.250 20.00 61.8 69.3 96.7 1.65 52.8 0.4
HXR 560L 88xx ≥ 4 40.00 63.00 16.00 6.250 12.00 1.500 22.00 61.8 74.6 119.3 1.89 67.7 3.0
Motor type
Poles J A P K B G D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 4.9 28.0 29.5 8.3 34.9 2.7 6317M/C3 6317M/C3
HXR 355L 58xx ≥ 4 4.9 28.0 29.5 8.3 34.9 2.7 6322/C3 6319/C3
HXR 400L 68xx 2 5.5 33.1 33.1 10.0 44.1 2.6 6317M/C3 6317M/C3
HXR 400L 68xx ≥ 4 5.5 33.1 33.1 10.0 44.1 2.6 6324/C3 6319/C3
HXR 450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.86 6317M/C3 6317M/C3
HXR 450L 72xx ≥ 4 6.3 37.4 37.0 12.6 51.2 1.86 6324/C3 6322/C3
HXR 500L 80xx 2 6.7 41.2 41.5 14.8 61.8 2.1 6319M/C3 6319M/C3
HXR 500L 80xx ≥ 4 6.7 41.2 41.5 14.8 61.8 2.1 6326/C3 6324/C3
HXR 560L 88xx ≥ 4 9.1 46.1 46.9 24.4 76.4 1.9 6034/C3 + NU1034/C3 NU322/C3
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 103
3
HV Cast iron motors, engineeredDimension drawings Sleeve bearings, 1000 < U ≤ 6900 V, TEFC, F1
Motor type
Poles 2E 2F BA U N-W F D FP O C H FDS BS
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 19.00 2.750 5.500 0.625 14.50 54.9 57.1 75.4 1.38 27.6 0.67
HXR 355L 58xx ≥ 4 25.00 25.00 19.00 4.000 8.250 1.000 14.50 54.9 57.1 81.9 1.38 27.6 0.67
HXR 400L 68xx 2 28.00 36.00 18.00 3.125 6.500 0.750 17.00 54.9 61.3 85.2 1.38 35.3 1.3
HXR 400L 68xx ≥ 4 28.00 36.00 18.00 4.375 8.250 1.000 17.00 54.9 61.3 90.7 1.38 35.3 1.3
HXR 450L 72xx 2 32.00 40.00 19.00 3.125 6.500 0.750 18.00 61.8 64.3 94.1 1.65 42.3 0.8
HXR 450L 72xx ≥ 4 32.00 40.00 19.00 4.375 8.250 1.000 18.00 61.8 64.3 99.6 1.65 42.3 0.8
HXR 500L 80xx 2 36.00 50.00 20.00 3.500 6.500 0.875 20.00 61.8 69.3 106.7 1.65 52.8 0.4
HXR 500L 80xx ≥ 4 36.00 50.00 20.00 4.750 8.250 1.250 20.00 61.8 69.3 112.2 1.65 52.8 0.4
HXR 560L 88xx ≥ 4 40.00 63.00 26.50 6.250 12.00 1.500 22.00 61.8 74.6 136.4 1.89 67.7 2.8
Motor type
Poles J A P K B G D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 355L 58xx ≥ 4 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-90 EFZLQ 9-90
HXR 400L 68xx 2 5.5 33.1 33.1 10.0 44.1 2.6 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 400L 68xx ≥ 4 5.5 33.1 33.1 10.0 44.1 2.6 EFZLB 9-100 EFZLQ 9-100
HXR 450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 450L 72xx ≥ 4 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-100 2) EFZLQ 9-100 2)
HXR 500L 80xx 2 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 9-90 1) EFZLQ 9-90 1)
HXR 500L 80xx ≥ 4 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 11-100 2) EFZLQ 9-100 2)
HXR 560L 88xx 4, 6 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-125 2) EFZLQ 14-125 2)
HXR 560L 88xx ≥ 4 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-140 EFZLQ 14-140
Note! Includes provision for BN proximity probes.Note! Axial float of rotor as standard ±0.31 inch.Note! The bearing can not withstand continuous axial forces.
1) With oil circulation as standard, see PIF 2a-3210 for pipe connections. 2) With oil circulation as standard for 4 poles, see PIF 2a-3210 for pipe connections.
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
104 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
HV Cast iron motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEFC, F2
Motor type
Poles 2E 2F BA U N-W F D FP O C H FDS BS
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 10.00 2.750 5.500 0.625 14.50 54.9 57.1 59.3 1.38 27.6 0.7
HXR 355L 58xx ≥ 4 25.00 25.00 10.00 4.000 8.250 1.000 14.50 54.9 57.1 65.7 1.38 27.6 0.7
HXR 400L 68xx 2 28.00 36.00 9.00 3.125 6.500 0.750 17.00 54.9 61.3 69.1 1.38 35.2 1.3
HXR 400L 68xx ≥ 4 28.00 36.00 9.00 4.375 8.250 1.000 17.00 54.9 61.3 74.6 1.38 35.2 1.3
HXR 450L 72xx 2 32.00 40.00 10.00 3.125 6.500 0.750 18.00 61.8 64.3 78.0 1.65 42.3 0.8
HXR 450L 72xx ≥ 4 32.00 40.00 10.00 4.375 8.250 1.000 18.00 61.8 64.3 83.5 1.65 42.3 0.8
HXR 500L 80xx 2 36.00 50.00 11.00 3.500 6.500 0.875 20.00 61.8 69.3 91.1 1.65 52.8 0.4
HXR 500L 80xx ≥ 4 36.00 50.00 11.00 4.750 8.250 1.250 20.00 61.8 69.3 96.7 1.65 52.8 0.4
HXR 560L 88xx ≥ 4 40.00 63.00 16.00 6.250 12.00 1.500 22.00 61.8 74.6 119.3 1.89 67.7 3.0
Motor type
Poles J A P K B G D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 4.9 28.0 29.5 8.3 34.9 2.7 6317M/C3 6317M/C3
HXR 355L 58xx ≥ 4 4.9 28.0 29.5 8.3 34.9 2.7 6322/C3 6319/C3
HXR 400L 68xx 2 5.5 33.1 33.1 10.0 44.1 2.6 6317M/C3 6317M/C3
HXR 400L 68xx ≥ 4 5.5 33.1 33.1 10.0 44.1 2.6 6324/C3 6319/C3
HXR 450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.85 6317M/C3 6317M/C3
HXR 450L 72xx ≥ 4 6.3 37.4 37.0 12.6 51.2 1.85 6324/C3 6322/C3
HXR 500L 80xx 2 6.7 41.2 41.5 14.8 61.8 2.1 6319M/C3 6319M/C3
HXR 500L 80xx ≥ 4 6.7 41.2 41.5 14.8 61.8 2.1 6326/C3 6324/C3
HXR 560L 88xx ≥ 4 9.1 46.1 46.9 24.5 76.4 1.9 6034/C3 + NU1034/C3 NU322/C3
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 105
3
HV Cast iron motors, engineeredDimension drawings Sleeve bearings, 1000 < U ≤ 6900 V, TEFC, F2
Motor type
Poles 2E 2F BA U N-W F D FP O C H FDS BS
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 19.00 2.750 5.500 0.625 14.50 54.9 57.1 75.4 1.38 27.6 0.67
HXR 355L 58xx ≥ 4 25.00 25.00 19.00 4.000 8.250 1.000 14.50 54.9 57.1 81.9 1.38 27.6 0.67
HXR 400L 68xx 2 28.00 36.00 18.00 3.125 6.500 0.750 17.00 54.9 61.3 85.2 1.38 35.3 1.3
HXR 400L 68xx ≥ 4 28.00 36.00 18.00 4.375 8.250 1.000 17.00 54.9 61.3 90.7 1.38 35.3 1.3
HXR 450L 72xx 2 32.00 40.00 19.00 3.125 6.500 0.750 18.00 61.8 64.3 94.1 1.65 42.3 0.8
HXR 450L 72xx ≥ 4 32.00 40.00 19.00 4.375 8.250 1.000 18.00 61.8 64.3 99.6 1.65 42.3 0.8
HXR 500L 80xx 2 36.00 50.00 20.00 3.500 6.500 0.875 20.00 61.8 69.3 106.7 1.65 52.8 0.4
HXR 500L 80xx ≥ 4 36.00 50.00 20.00 4.750 8.250 1.250 20.00 61.8 69.3 112.2 1.65 52.8 0.4
HXR 560L 88xx ≥ 4 40.00 63.00 26.50 6.250 12.00 1.500 22.00 61.8 74.6 136.4 1.89 67.7 2.8
Motor type
Poles J A P K B G D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 355L 58xx ≥ 4 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-90 EFZLQ 9-90
HXR 400L 68xx 2 5.5 33.1 33.1 10.0 44.1 2.6 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 400L 68xx ≥ 4 5.5 33.1 33.1 10.0 44.1 2.6 EFZLB 9-100 EFZLQ 9-100
HXR 450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-80 1) EFZLQ 9-80 1)
HXR 450L 72xx ≥ 4 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-100 2) EFZLQ 9-100 2)
HXR 500L 80xx 2 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 9-90 1) EFZLQ 9-90 1)
HXR 500L 80xx ≥ 4 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 11-100 2) EFZLQ 9-100 2)
HXR 560L 88xx 4, 6 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-125 2) EFZLQ 14-125 2)
HXR 560L 88xx ≥ 4 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-140 EFZLQ 14-140
Note! Includes provision for BN proximity probes.Note! Axial float of rotor as standard ±0.31 inch.Note! The bearing can not withstand continuous axial forces.
1) With oil circulation as standard, see PIF 2a-3210 for pipe connections. 2) With oil circulation as standard for 4 poles, see PIF 2a-3210 for pipe connections.
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
106 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
HV Cast iron motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEFC, F1, flange mounting
Motor type
Poles 2E 2F A AB AC AE AF AJ AK B BA BB BD
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50HXR 355L 58xx ≥ 4 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50
HXR 400L 68xx 2 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37HXR 400L 68xx ≥ 4 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37HXR 450L 72xx 2 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28HXR 450L 72xx ≥ 4 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28HXR 500L 80xx 2 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28HXR 500L 80xx ≥ 4 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28HXR 560L 88xx ≥ 4 40.00 63.00 46.1 40.7 32.4 53.5 18.4 51.97 49.21 76.4 16.00 0.236 55.12
Motor type
Poles BE BF BS C D EV F FDS G H J K
IEC NEMA
HXR 355L 58xx 2 0.984 0.945 27.0 59.3 14.50 4.2 0.625 0.55 2.68 1.38 4.9 8.3HXR 355L 58xx ≥ 4 0.984 0.945 27.0 65.7 14.50 4.2 1.000 0.55 2.68 1.38 4.9 8.3HXR 400L 68xx 2 1.181 1.102 36.2 69.1 17.00 3.4 0.750 0.95 2.64 1.38 5.5 10.0HXR 400L 68xx ≥ 4 1.181 1.102 36.2 74.6 17.00 3.4 1.000 0.95 2.64 1.38 5.5 10.0HXR 450L 72xx 2 1.181 1.102 43.0 78.0 18.00 3.7 0.750 0.63 1.85 1.65 6.3 12.6HXR 450L 72xx ≥ 4 1.181 1.102 43.0 83.5 18.00 3.7 1.000 0.63 1.85 1.65 6.3 12.6HXR 500L 80xx 2 1.181 1.102 53.6 91.1 20.00 3.9 0.875 0.83 2.09 1.65 6.7 14.8HXR 500L 80xx ≥ 4 1.181 1.102 53.6 96.7 20.00 3.9 1.250 0.83 2.09 1.65 6.7 14.8HXR 560L 88xx ≥ 4 2.362 1.102 65.5 119.3 22.00 6.9 1.500 2.21 1.93 1.89 9.1 24.4
Motor type
Poles N-W O P U D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 5.500 57.1 29.5 2.750 6317/C3 6317/C3HXR 355L 58xx ≥ 4 8.250 57.1 29.5 4.000 6322/C3 6319/C3HXR 400L 68xx 2 6.500 61.3 33.1 3.125 6317/C3 6317/C3HXR 400L 68xx ≥ 4 8.250 61.3 33.1 4.375 6324/C3 6319/C3HXR 450L 72xx 2 6.500 64.3 37.0 3.125 6317/C3 6317/C3HXR 450L 72xx ≥ 4 8.250 64.3 37.0 4.375 6324/C3 6322/C3HXR 500L 80xx 2 6.500 69.3 40.9 3.500 6319M/C3 6319M/C3HXR 500L 80xx ≥ 4 8.250 69.3 40.9 4.750 6326/C3 6324/C3HXR 560L 88xx ≥ 4 12.00 74.6 46.9 6.250 6034/C3 + NU1034/C3 NU322/C3
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 107
3
HV Cast iron motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEFC, F2, flange mounting
Motor type
Poles 2E 2F A AB AC AE AF AJ AK B BA BB BD
IEC NEMA
HXR 355L 58xx 2 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50HXR 355L 58xx ≥ 4 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50HXR 400L 68xx 2 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37HXR 400L 68xx ≥ 4 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37HXR 450L 72xx 2 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28HXR 450L 72xx ≥ 4 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28HXR 500L 80xx 2 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28HXR 500L 80xx ≥ 4 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28HXR 560L 88xx ≥ 4 40.00 63.00 46.1 40.7 32.4 53.5 18.4 51.97 49.21 76.4 16.00 0.236 55.12
Motor type
Poles BE BF BS C D EV F FDS G H J K
IEC NEMA
HXR 355L 58xx 2 0.984 0.945 27.0 59.3 14.50 4.2 0.625 0.55 2.68 1.38 4.9 8.3HXR 355L 58xx ≥ 4 0.984 0.945 27.0 65.7 14.50 4.2 1.000 0.55 2.68 1.38 4.9 8.3HXR 400L 68xx 2 1.181 1.102 36.2 69.1 17.00 3.4 0.750 0.95 2.64 1.38 5.5 10.0HXR 400L 68xx ≥ 4 1.181 1.102 36.2 74.6 17.00 3.4 1.000 0.95 2.64 1.38 5.5 10.0HXR 450L 72xx 2 1.181 1.102 43.0 78.0 18.00 3.7 0.750 0.63 1.85 1.65 6.3 12.6HXR 450L 72xx ≥ 4 1.181 1.102 43.0 83.5 18.00 3.7 1.000 0.63 1.85 1.65 6.3 12.6HXR 500L 80xx 2 1.181 1.102 53.6 91.1 20.00 3.9 0.875 0.83 2.09 1.65 6.7 14.8HXR 500L 80xx ≥ 4 1.181 1.102 53.6 96.7 20.00 3.9 1.250 0.83 2.09 1.65 6.7 14.8HXR 560L 88xx ≥ 4 2.362 1.102 65.5 119.3 22.00 6.9 1.500 2.21 1.93 1.89 9.1 24.4
Motor type
Poles N-W O P U D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx 2 5.500 57.1 29.5 2.750 6317/C3 6317/C3HXR 355L 58xx ≥ 4 8.250 57.1 29.5 4.000 6322/C3 6319/C3HXR 400L 68xx 2 6.500 61.3 33.1 3.125 6317/C3 6317/C3HXR 400L 68xx ≥ 4 8.250 61.3 33.1 4.375 6324/C3 6319/C3HXR 450L 72xx 2 6.500 64.3 37.0 3.125 6317/C3 6317/C3HXR 450L 72xx ≥ 4 8.250 64.3 37.0 4.375 6324/C3 6322/C3HXR 500L 80xx 2 6.500 69.3 40.9 3.500 6319M/C3 6319M/C3HXR 500L 80xx ≥ 4 8.250 69.3 40.9 4.750 6326/C3 6324/C3HXR 560L 88xx ≥ 4 12.00 74.6 46.9 6.250 6034/C3 + NU1034/C3 NU322/C3
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.
108 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
HV Cast iron motors, engineeredDimension drawings Antifriction bearings, 1000 < U ≤ 6900 V, TEFC, vertical
Motor type
Poles AB AC AF AJ AK BB BD BE BF BV C F
IEC NEMA
HXR 355L 58xx ≥ 4 41.00 32.70 18.40 29.13 26.77 0.236 31.50 0.984 0.945 37.00 65.70 1.000
HXR 400L 68xx ≥ 4 42.70 34.45 18.40 37.00 34.65 0.236 39.37 1.181 1.102 45.20 74.60 1.000
HXR 450L 72xx ≥ 4 44.70 36.40 18.40 42.52 39.37 0.236 45.28 1.181 1.102 52.95 83.50 1.000
HXR 500L 80xx ≥ 4 47.60 39.40 18.40 42.52 39.37 0.236 45.28 1.181 1.102 64.60 96.70 1.250
HXR 560L 88xx ≥ 6 51.00 42.70 18.40 51.97 49.21 0.236 55.12 1.575 1.102 80.70 118.5 1.500
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the foundation. Certified outline drawing is delivered with each purchase order. The motor's rotational direction will be as specified in the order.Rain canopy is recommended for outdoor location.
Motor type
Poles FDS N-W P U D-end bearing N-end bearing
IEC NEMA
HXR 355L 58xx ≥ 4 10.0 8.250 29.5 4.000 6322/C3 7319 BM
HXR 400L 68xx ≥ 4 10.0 8.250 33.1 4.375 6324/C3 7319 BM
HXR 450L 72xx ≥ 4 10.6 8.250 37.0 4.375 6324/C3 7322 BM
HXR 500L 80xx ≥ 4 11.8 8.250 40.9 4.750 6326/C3 7324 BM
HXR 560L 88xx ≥ 6 13.0 12.00 46.9 6.250 6034/C3 7334 BM
ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009 109
3
The picture shows high voltage terminal box with its main technical data below.
Technical data:
Voltage (max.) 6.9 kVCurrent (max.) 600 ANo of cables (max.) 2 per phaseCable gland blind gland (1 pce)Connection hooks 0.3" x 2.36" (3 pcs)Clearance (min.) 5.9 inCreepage (min.) 10 inUsable volume 18 000 in3
Ground connections M16 (both in- and outside)Weight 230 lbsProtection NEMA 4Standard NEMA MG 1, Part 20
Materials: Box welded sheet steel
(thickness min. 0.12") Cable gland plate steel Connection hooks Copper Cu Isolators epoxy casting resin Grounding pad stainless steel
Other features:
- rigid welded construction- ample size for making connections of supply cables- box turnable to allow cable entry from left or right side- box turnable in steps of 90°- either 3-phase or 1-phase cables can be connected- all removable cover plates are bolted and gasketed- different cable glands available.
NEMA type II terminal box (normal size)
Figure above: High voltage NEMA Type II terminal box (normal size). Dimensions in inches [mm].
110 ABB /BU Machines/NEMA catalogue/Engineered motors, HXR & AMA EN 02-2009
3
The picture shows high voltage terminal box with its main technical data below.
Technical data:Voltage (max.) 6.9 kVCurrent (max.) 600 ANo of cables (max.) 2 per phaseCable gland blind gland (1 pce)Connection hooks 0.3" x 2.36" (3 pcs)Clearance (min.) 5.9 inCreepage (min.) 10 inUsable volume 36 000 in3 Ground connections M16 (both in- and outside)Weight 375 lbsProtection NEMA 4Standard NEMA MG 1, Part 20
Materials: Box welded sheet steel (thickness min. 0.12") Cable gland plate steel Connection hooks Copper Cu Isolators epoxy casting resin Grounding pad stainless steel
Other features:- rigid welded construction- ample size for making connections of supply cables- box turnable to allow cable entry from left or right side- box turnable in steps of 90°- either 3-phase or 1-phase cables can be connected- all removable cover plates are bolted and gasketed- different cable glands available- can be equipped with: current transformer (CT), lightning arrester (LA), surge capasitor (SC)
NEMA type II terminal box (over size)
Figure above: High voltage NEMA Type II terminal box (over size). Dimensions in inches [mm].
ABB /BU Machines/NEMA catalogue EN 02-2009 111
ABB Motors’ total product offerABB offers several comprehensive ranges of AC motors and generators. We manufacture synchronous motors for even the most demanding applications, and a full range of low and high voltage induction motors. Our in-depth knowledge of virtually every type of industrial processing ensures we always specify the best solution for your needs.
High voltage and synchronous motors and generators– High voltage cast iron motors– Induction modular motors– Slip ring motors– Motors for hazardous areas– Servomotors– Synchronous motors and generators– DC motors and generators
Low voltage motors and generatorsGeneral purpose motors forstandard applications– Aluminum motors– Steel motors– Cast iron motors– Open drip proof motors– Global motors– Brake motors– Single phase motors– Integral motors
Process performance motors formore demanding applications– Aluminum motors– Cast iron motors– Motors for high ambient temperatures
NEMA motors
Motors for hazardous areas– Flameproof motors– Increased safety motors– Non-sparking motors– Dust ignition proof motors
Marine motors– Aluminum motors– Steel motors– Cast iron motors– Open drip proof motors
Other applications– Permanent magnet motors– High speed motors– Wind turbine generators– Smoke venting motors– Water cooled motors– Motors for roller table drives
9AK
K10
4709
EN
02-
2009
www.abb.com/motors&generators
ABB (www.abb.com) is a leader in power and automation
technologies that enable utility and industry customers to
improve their performance while lowering environmental
impact. The ABB Group of companies operates in around
100 countries and employs about 120,000 people.
ABB's web site provides further information, including a library of documents. Visit www.abb.com/motors&generators.
www.abb.com/motors&generators> Motors
>> High Voltage Motors
>>> Cast Iron Motors, HXR
>>> NEMA Motors, TEFC
>>> Induction Motors, Modular
Ava
ilabl
e in
ele
ctro
nic
form
at o
nly.