Post on 07-May-2019
transcript
Scale: 1/2" = 1'-0"
TYPICAL GRID LAYOUT
3
4
E01
1'-4
" [4
06
]
4'-0" [1219]
12 GAUGE HANGER WIRE,
SPACED AT 4'-0" [1219] O.C.
INCLUDE ISBAC CLIP NEAR
EVERY HANGER WIRE, TYPICAL.
DRYWALL SUSPENSION SYSTEM
MAIN TEES DGLW-26 AT 16" [406]
O.C.
INDEXED SUPPORT BAR
SUPPORT AT 48" [1219] O.C.
DGCM-27 C CHANNEL
ATTACHED TO ENDS
OF DGLW-26 TEES
EQUAL, 2'-0"
[610] MAX.
EQUAL, 2'-0"
[610] MAX.
1'-4
" [4
06
]
MA
X
Scale: 1/2" = 1'-0"
TYPICAL REFLECTED CEILING PLAN
1
8
E02
4
E02
2,6
E02
9
E02
10
E02
13
E02
12
E02
11
E02
ISSUE LOG
US
G C
OR
PO
RA
TIO
N
Un
ite
d S
ta
te
s G
yp
su
m C
om
pa
ny
55
0
WE
ST
A
DA
MS
S
TR
EE
T
CH
IC
AG
O,
I
LL
IN
OI
S
6
06
61
US
G-
4Y
OU
W
WW
.U
SG
.C
OM
SHEET INFORMATION
ABCDE
43
21
ABCDE
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN
ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BY
ARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS,
CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHER
COMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS
HAVING AN INTEREST IN THE SELECTION, SPECIFICATION AND
USE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF
USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY AS
TECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG
PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THE
DESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN
PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BE
PRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS
NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES AND
BIM (BUILDING INFORMATION MODELING ) FILES CAN BE
MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION
OF SUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD
DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGN
PROFESSIONAL.
06/06/20170
1 OF 3
E01
USG ENSEMBLE
ACOUSTICAL
DRYWALL CEILING
EN
SE
MB
LE
A
CO
US
TIC
AL
D
RY
WA
LL
US
G S
C 2
78
9
CE
IL
IN
G D
ET
AIL
S
1. ALL DRYWALL CEILING APPLICATIONS MUST COMPLY WITH
LOCAL CODES & ORDNANCES FOR CEILING SUPPORT,
DIAGONAL BRACING AND SEISMIC BRACING SYSTEMS. THE
WIRE GAUGE, SPACING AND DESIGN OF THESE SYSTEMS ARE
THE RESPONSIBILITY OF THE ARCHITECT AND PROJECT
STRUCTURAL ENGINEER.
2. REFERENCE USG DRYWALL SUSPENSION GRID INSTALLATION
BROCHURE AC3152 FOR RECOMMENDED INSTALLATION
GUIDELINES.
3. REFERENCE USG GYPSUM CONSTRUCTION HANDBOOK FOR
CONTROL JOINT CRITERIA
4. REFERENCE USG LITERATURE SC2495 AND SEISMIC
CEILINGS.COM FOR APPROPRIATE SEISMIC DETAILS AND
INFORMATION, ALL SEISMIC CRITERIA TO BE VERIFIED BY
PROJECT STRUCTURAL ENGINEER AND ARCHITECT.
5. REFERENCE USG LITERATURE FOR PROPER FASTENER
SPACING AT CEILING ASSEMBLIES.
6. REFERENCE USG IS268 FOR INFORMATION ON INTEGRATED
LOGIX CEILING DESIGN.
7. REFERENCE 14 & 15 /E02 FOR BLACKIRON DETAILS TYPICAL.
MAXIMUM SPACING OF CONTROL JOINTS
50
30
15
9
2500
900
230
85
CONSTRUCTION & LOCATION
INTERIOR CEILING
WITH PERIMETER RELIEF
INTERIOR CEILING WITHOUT
PERIMETER RELIEF
FT
2
M
2
METERSFEET
MAX. DIMENSION MAX. AREA
GENERAL NOTES CONTROL JOINT CRITERIA
Scale: 1/2" = 1'-0"
TYPICAL GRID LAYOUT
4
Scale: 1/2" = 1'-0"
PANEL LAYOUT
2
USG FIBEROCK STRIPS
AT ALL NON-SUPPORTED
PANEL JOINTS
STAGGER JOINTS
48" TYPICAL
4
E01
4
E01
3
E02
DGLW26 MAIN TEE
ISB109 INDEXED SUPPORT BAR
12 GAUGE HANGER WIRE, NOTE:
INCLUDE ISBAC ATTACHMENT CLIP
NEAR EACH HANGER WIRE, TYPICAL.
USG SHEETROCK BRAND
ENSEMBLE
TM
PERFORATED
GYPSUM PANELS
USG FIBEROCK
TM
END JOINT
BACKER PANELS
USG ENSEMBLE
TM
HIGH
NRC BACKER PANELS
USG ENSEMBLE
TM
SPRAY
APPLIED FINISH
1,5
E02
10
E02
7
E02
LEGEND
Scale: 1/2" = 1'-0"
BLACK IRON TYPICAL LAYOUT
5
1,5
E02
10
E02
X
E02
TM
USG ENSEMBLE
™
ACOUSTICAL
DRYWALL CEILING
USG SC2789
DISCLAIMER: USG SYSTEM DETAILS CONTAINED HEREWITH IS INTENDED FOR USE AS
PRODUCT REFERENCE MATERIAL FOR LICENSED DESIGN PROFESSIONALS ONLY. USG
RECOMMENDS ALL RELEVANT CEILING LITERATURE & INSTALLATION GUIDES BE
REVIEWED PRIOR TO MODIFYING THE DETAILS CONTAINED IN THIS LITERATURE. THESE
MATERIALS MAY BE PRINTED AND/OR TRANSFERRED ELECTRONICALLY AS NEEDED BY
THE USER. THE LICENSED DESIGN PROFESSIONAL THAT STAMPS THE CONSTRUCTION
DRAWING SETS ARE SOLELY RESPONSIBLE FOR ALL MODIFICATIONS TO THE DETAILS. IN
ADDITION THEY ARE RESPONSIBLE FOR THE VERIFICATION THAT THE DETAILS COMPLY
WITH LOCAL BUILDING CODE CRITERIA REQUIRED FOR PROJECT COMPLIANCE. ANY
UNAUTHORIZED DUPLICATION OR REUSE OF THE MATERIAL CONTAINED HEREIN IS A
VIOLATION OF LAW.
SCALE: 3" = 1'-0"
MONOLITHIC CEILING AT SPRINKLER
13
USG ENSEMBLE CEILING
SWING-ARM ASSEMBLY IS RECOMMENDED TO
ALLOW ALIGNMENT IN CEILING (SUPPORT TO
STRUCTURE ABOVE), BY OTHERS
ESCUTCHEON FLANGE TO LAY
FLAT AGAINST DRYWALL CEILING
12 GAUGE HANGER WIRE
SCALE: 3"=1'-0"
LINEAR OPENING WITH LOGIX YOKE
10
USG ENSEMBLE CEILING
DO NOT OVER
TIGHTEN RIM
CLIPS, TYPICAL
SUPPORT TO STRUCTURE
ABOVE, BY OTHERS
ATTACH STABILIZER BARS TO GRID.
LOAD OF FIXTURE AND HOUSING TO
BE SUPPORTED FROM STRUCTURE
ABOVE, TYPICAL
SCALE: 3"=1'-0"
POINT LIGHT FIXTURE AT MONOLITHIC CEILING
11
USG ENSEMBLE CEILING
SCALE: 3"=1'-0"
ACCESS PANEL AT MONOLITHIC CEILING
12
USG ENSEMBLE CEILING
12 GAUGE HANGER WIRE
METAL OR DRYWALL ACCESS PANEL (BY OTHERS)
SPECIFICATION BY ARCHITECT, REFERENCE
ACCESS PANEL LITERATURE FOR REQUIRED
SUPPORT AND ATTACHMENT DETAILS.
USG DRYWALL MAIN
USG LOGIX YOKE, CONNECT TO ISB PER
INSTALLATION MANUAL, REFERENCE
USG IS268 FOR OPENING WIDTHS.
USG ENSEMBLE™ HIGH NRC
BACKER PANEL.
USG SHEETROCK® BRAND ENSEMBLE™
CEILING COMPOUND.
USG SHEETROCK
®
BRAND ENSEMBLE™
PANEL.
J-TRIM, FINISH PER ARCHITECT.
REF USG
IS268
USG SHEETROCK® BRAND
ENSEMBLE™ CEILING COMPOUND.
12 GAUGE HANGER WIRE.
USG SHEETROCK® BRAND
ENSEMBLE™ CEILING COMPOUND.
CAREFULLY COVER ALL OPENINGS AND TRIM RINGS
PRIOR TO APPLICATION OF SPRAY APPLIED FINISH.
USG DWSS
MAIN TEE
12 GAUGE
HANGER WIRE
USG INDEXED SUPPORT BAR (ISB)
REFERENCE LOGIX INSTALLATION
GUIDE AT CONNECTIONS, TYPICAL.
USG INDEXED SUPPORT BAR (ISB)
SCALE: 3" = 1'-0"
FLOATING END JOINT DETAIL
9
USG ENSEMBLE CEILING
USG ENSEMBLE™ SPRAY
APPLIED FINISH.
USG ENSEMBLE™
HIGH-NRC BACKER PANEL.
USG SHEETROCK
®
BRAND
ENSEMBLE™ PANELS.
12 GAUGE HANGER WIRE
USG INDEXED SUPPORT BAR (ISB).
USG DRYWALL
SUSPENSION MAIN TEE.
INDEXED SUPPORT BAR
ATTACHMENT CLIP (ISBMC)
FINISH END JOINT.
USG FIBEROCK™ PANEL.
SCALE: 6" = 1'-0"
TYPICAL CONTROL JOINT
8
USG ENSEMBLE CEILING
1/2" [13]
USG 093 CONTROL JOINT
3/8" [10]
USG WALL ANGLE.
FASTEN TO WALL
FRAMING, TYPICAL.
J TRIM.
SCALE: 6" = 1'-0"
COMPASSO ELITE WITH DRYWALL EDGE
5
USG ENSEMBLE CEILING
USG COMPASSO ELITE DRYWALL
TRIM, SIZE PER ARCHITECT.
6" [152]
℄
12 GAUGE HANGER WIRE
12 GAUGE HANGER WIRE
USG CPALAC1 CLIP.
CAULK.
SCALE: 6" = 1'-0"
PANEL JOINT DETAIL
3
USG ENSEMBLE CEILING
USG ENSEMBLE™
SPRAY-APPLIED FINISH.
USG ENSEMBLE™
HIGH-NRC BACKER PANEL.
USG SHEETROCK
®
BRAND
ENSEMBLE™ PANELS.
12 GAUGE HANGER WIRE
SCALE: 6"=1'-0"
DETAIL AT REVEAL MOLDING
7
USG ENSEMBLE CEILING
SCALE: 6" = 1'-0"
TYPICAL REVEAL JOINT
4
USG ENSEMBLE CEILING
REVEAL JOINT
SCALE: 6" = 1'-0"
DRYWALL EDGE
1
USG ENSEMBLE CEILING
USG DONN SL TRANSITION MOLDING.
USG SHEETROCK
®
BRAND
ENSEMBLE™ PANEL.
SCALE: 6"=1'-0"
TRANSITION DETAIL
2
USG ENSEMBLE CEILING
SCALE: 6" = 1'-0"
MONOLITHIC TO GRID CEILING TILE TRANSITION
6
USG ENSEMBLE CEILING
8" [200] MAX
ATTACH ISB TO PERIMETER
WALL WITH CUT M9 ANGLE.
8" [200] MAX
USG ENSEMBLE™
HIGH-NRC BACKER PANEL.
USG ENSEMBLE™ SPRAY-APPLIED FINISH.
USG SHEETROCK
®
BRAND ENSEMBLE™ PANEL.
USG COMPÄSSO™
ELITE DAS TRIM.
ACOUSTICAL CEILING PANEL.
GRID TEE.
USG CPALAC1 CLIP.
USG DRYWALL SUSPENSION
SYSTEM MAIN TEE.
12 GAUGE HANGER WIRE.
GRID TEE.
ACOUSTICAL CEILING PANEL.
USG INDEXED SUPPORT BAR (ISB).
12 GAUGE HANGER WIRE.
USG CPALAC1 CLIP.
USG SHEETROCK® BRAND
ENSEMBLE™ CEILING COMPOUND.
USG ENSEMBLE™ HIGH NRC BACKER PANEL.
USG ENSEMBLE™ SPRAY-APPLIED FINISH.
USG SHEETROCK
®
BRAND ENSEMBLE™
PANEL.
USG ISB (INDEXED SUPPORT BAR).
USG SHEETROCK® BRAND
ENSEMBLE™ CEILING COMPOUND.
USG DRYWALL SUSPENSION TEE.
USG DRYWALL SUSPENSION
SYSTEM MAIN TEE.
USG ENSEMBLE OR SHEETROCK,
SIZE PER ARCHITECT.
12 GAUGE HANGER WIRE
USG DGWM24 ANGLE TRIM.
USG ENSEMBLE™ HIGH
NRC BACKER PANEL.
USG ENSEMBLE™ SPRAY- APPLIED FINISH.
USG SHEETROCK
®
BRAND ENSEMBLE™
PANEL.
USG INDEXED
SUPPORT BAR (ISB).
USG SHEETROCK® BRAND
ENSEMBLE™ CEILING COMPOUND.
USG DRYWALL SUSPENSION
SYSTEM MAIN TEE.
4" [102] M
IN
.
USG INDEXED SUPPORT BAR (ISB).
USG ENSEMBLE™ HIGH
NRC BACKER PANEL.
USG SHEETROCK® BRAND
ENSEMBLE™ CEILING COMPOUND.
USG SHEETROCK® BRAND
ENSEMBLE™ CEILING COMPOUND.
USG SHEETROCK
®
BRAND
ENSEMBLE™ PANEL.
USG ENSEMBLE™ HIGH
NRC BACKER PANEL .
USG INDEXED SUPPORT BAR (ISB).
USG DRYWALL SUSPENSION
SYSTEM MAIN TEE.
USG INDEXED SUPPORT BAR (ISB).
USG DRYWALL
SUSPENSION MAIN TEE.
USG SHEETROCK® BRAND
ENSEMBLE™ CEILING COMPOUND.
USG ENSEMBLE™
HIGH-NRC BACKER PANEL
USG SHEETROCK
®
BRAND ENSEMBLE™
PANEL.
12 GAUGE HANGER WIRE
USG INDEXED SUPPORT BAR (ISB)
USG DRYWALL SUSPENSION
SYSTEM MAIN TEE
USG ENSEMBLE™
HIGH-NRC BACKER PANEL
USG INDEXED SUPPORT BAR (ISB)
USG DRYWALL SUSPENSION
SYSTEM MAIN TEE
USG SHEETROCK® BRAND ENSEMBLE™
CEILING COMPOUND,
APPLY AT ALL PANEL JOINTS.
USG ENSEMBLE™ SPRAY APPLIED FINISH
USG SHEETROCK
®
BRAND ENSEMBLE™
PANEL.
USG ENSEMBLE™ SPRAY APPLIED FINISH
USG DGCM27 TRIM
USG SHEETROCK
®
BRAND PAPER JOINT TAPE.
USG SHEETROCK® BRAND ENSEMBLE™
CEILING COMPOUND.
12 GAUGE HANGER WIRE
INDEXED SUPPORT BAR
ATTACHMENT CLIP (ISBMC).
USG SHEETROCK® BRAND ENSEMBLE™
CEILING COMPOUND,
APPLY AT ALL PANEL JOINTS.
BRACE AS NEEDED
NOTE: PROVIDE CLEARANCE
BETWEEN CLIP AND ACOUSTICAL
BACKER PANEL.
ISB ATTACHMENT CLIP (ISBAC).
ISB ATTACHMENT CLIP (ISBAC).
USG ENSEMBLE™
SPRAY-APPLIED FINISH.
USG SHEETROCK
®
BRAND
ENSEMBLE™ PANELS.
SCALE: 6" = 1'-0"
BLACK IRON DETAIL PERPENDICULAR TO DWSS TEE
15
USG ENSEMBLE™ CEILING
USG SHEETROCK® BRAND
ENSEMBLE™ CEILING COMPOUND.
USG SHEETROCK
®
BRAND ENSEMBLE™
PANEL.
USG SHEETROCK
®
BRAND
PAPER JOINT TAPE.
USG SHEETROCK® BRAND ENSEMBLE™
CEILING COMPOUND,
APPLY AT ALL PANEL JOINTS.
SCALE: 6" = 1'-0"
BLACK IRON DETAIL PARALLEL TO DWSS MAIN TEE
14
USG ENSEMBLE™ CEILING
USG ENSEMBLE™
HIGH-NRC BACKER PANEL.
HOLD-DOWN CLIP (BY OTHERS).
USG ENSEMBLE™ HIGH-NRC BACKER PANEL.
HOLD-DOWN CLIP (BY OTHERS).
DIRECT HANG ATTACHMENT CLIP
(BY OTHERS) SUSPENDED FROM
STEEL CHANNEL TO MAIN TEE,
PLACED 16 INCHES O.C. MAX.
USG CC15-80-16 STABILIZER BAR
48" O.C. MAX.
USG DRYWALL SUSPENSION SYSTEM
MAIN TEE @ 16" [450] O.C. TYPICAL.
CHANNEL TO ROD CLIP
(BY OTHERS).
STEEL HANGING ROD
(BY OTHERS).
STEEL CARRYING
CHANNEL (BY OTHERS).
CHANNEL TO ROD CLIP
(BY OTHERS).
STEEL HANGING ROD
(BY OTHERS).
STEEL CARRYING
CHANNEL (BY OTHERS).
USG CC15-80-16 STABILIZER BAR
48" O.C. MAX.
USG DRYWALL SUSPENSION
MAIN TEE.
DIRECT HANG ATTACHMENT CLIP (BY OTHERS)
SUSPENDED FROM STEEL CHANNEL TO MAIN
TEE, PLACED 16 INCHES O.C. MAX.
ISSUE LOG
US
G C
OR
PO
RA
TIO
N
Un
ite
d S
ta
te
s G
yp
su
m C
om
pa
ny
55
0
WE
ST
A
DA
MS
S
TR
EE
T
CH
IC
AG
O,
I
LL
IN
OI
S
6
06
61
US
G-
4Y
OU
W
WW
.U
SG
.C
OM
SHEET INFORMATION
ABCDE
43
21
ABCDE
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN
ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BY
ARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS,
CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHER
COMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS
HAVING AN INTEREST IN THE SELECTION, SPECIFICATION AND
USE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF
USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY AS
TECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG
PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THE
DESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN
PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BE
PRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS
NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES AND
BIM (BUILDING INFORMATION MODELING ) FILES CAN BE
MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION
OF SUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD
DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGN
PROFESSIONAL.
03/15/20181
06/06/20170
2 OF 3
E02
USG ENSEMBLE
ACOUSTICAL
DRYWALL CEILING
EN
SE
MB
LE
A
CO
US
TIC
AL
D
RY
WA
LL
US
G S
C 2
78
9
CE
IL
IN
G D
ET
AIL
S
TM
12 GAUGE HANGER WIRE .
USG ENSEMBLE™ HIGH
NRC BACKER PANEL.
USG ENSEMBLE™ SPRAY- APPLIED FINISH.
USG SHEETROCK
®
BRAND ENSEMBLE™
PANEL.
USG DRYWALL SUSPENSION
SYSTEM MAIN TEE.
USG SHEETROCK
®
BRAND PAPER FACED
METAL "J" SHAPED
TAPE-ON TRIM (B9) OR
"L" SHAPED TAPE ON
TRIM (B4 SERIES).
1" X 3" ANGLE, PAINT,
COLOR PER
ARCHITECT.
USG INDEXED
SUPPORT BAR (ISB).
4" [102] MAX.
℄
SCALE: 6" = 1'-0"
LOW PROFILE EDGE DETAIL
18
USG ENSEMBLE CEILING
USG ENSEMBLE™
SPRAY- APPLIED
FINISH.
USG ENSEMBLE™
SPRAY-APPLIED FINISH.
USG SHEETROCK
®
BRAND
ENSEMBLE™ PANELS.
SCALE: 6" = 1'-0"
ALT. BLACK IRON DTL PERPENDICULAR TO DWSS MT
17
USG ENSEMBLE™ CEILING
USG SHEETROCK® BRAND
ENSEMBLE™ CEILING COMPOUND.
USG SHEETROCK
®
BRAND ENSEMBLE™
PANEL.
USG SHEETROCK
®
BRAND
PAPER JOINT TAPE.
USG SHEETROCK® BRAND ENSEMBLE™
CEILING COMPOUND,
APPLY AT ALL PANEL JOINTS.
SCALE: 6" = 1'-0"
ALT. BLACK IRON DTL PARALLEL TO DWSS MAIN TEE
16
USG ENSEMBLE™ CEILING
USG ENSEMBLE™
HIGH-NRC BACKER PANEL.
HOLD-DOWN CLIP (BY OTHERS).
USG ENSEMBLE™ HIGH-NRC BACKER PANEL.
HOLD-DOWN CLIP (BY OTHERS).
DIRECT HANG ATTACHMENT CLIP
(BY OTHERS) SUSPENDED FROM
STEEL CHANNEL TO MAIN TEE,
PLACED 16 INCHES O.C. MAX.
USG INDEXED SUPPORT BAR (ISB).
USG DRYWALL SUSPENSION SYSTEM
MAIN TEE @ 16" [450] O.C. TYPICAL.
CHANNEL TO ROD CLIP
(BY OTHERS).
STEEL HANGING ROD
(BY OTHERS).
STEEL CARRYING
CHANNEL (BY OTHERS).
CHANNEL TO ROD CLIP
(BY OTHERS).
STEEL HANGING ROD
(BY OTHERS).
STEEL CARRYING
CHANNEL (BY OTHERS).
USG INDEXED SUPPORT BAR (ISB)
@ 4'-0" [1250] O.C. TYPICAL.
USG DRYWALL SUSPENSION
MAIN TEE.
DIRECT HANG ATTACHMENT CLIP (BY OTHERS)
SUSPENDED FROM STEEL CHANNEL TO MAIN
TEE, PLACED 16 INCHES O.C. MAX.
ISSUE LOG
US
G C
OR
PO
RA
TIO
N
Un
ite
d S
ta
te
s G
yp
su
m C
om
pa
ny
55
0
WE
ST
A
DA
MS
S
TR
EE
T
CH
IC
AG
O,
I
LL
IN
OI
S
6
06
61
US
G-
4Y
OU
W
WW
.U
SG
.C
OM
SHEET INFORMATION
ABCDE
43
21
ABCDE
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN
ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BY
ARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS,
CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHER
COMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS
HAVING AN INTEREST IN THE SELECTION, SPECIFICATION AND
USE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF
USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY AS
TECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG
PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THE
DESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN
PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BE
PRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS
NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES AND
BIM (BUILDING INFORMATION MODELING ) FILES CAN BE
MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION
OF SUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD
DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGN
PROFESSIONAL.
07/26/20180
3 OF 3
E03
USG ENSEMBLE™
ACOUSTICAL
DRYWALL CEILING
EN
SE
MB
LE
A
CO
US
TIC
AL
D
RY
WA
LL
US
G S
C 2
78
9
CE
IL
IN
G D
ET
AIL
S
TM