Post on 07-Nov-2014
transcript
EXISTING CORRUGATED
METAL ROOF TO BE
RETAINED
PL+104.10
PL+104.285
33
34
8
33
34
8
33
34
8
33
34
1031
6
13
1
1a
1
1a
1
1a
1
1a
1a1a1a1a
1
10
OPEN
PL+104.285PL+104.285
PL+104.00
1a 1a1 1112
10
3333
3434
33
34
33
34
8
8
2 2
1
8
8 8
8 8
2 2 2
2 2 2 2 2 2
33
AMSL + 14.23
AMSL + 14.23
1
A
COPYRIGHT @ 2011, SWAN AND MACLAREN INTERNATIONAL PTE LTD
Internet: www.swanmaclaren.com
158 Cecil Street #06-01
Singapore 069545
THE OWNERSHIP OF THE COPYRIGHT IN THIS DRAWING IS RETAINED BY SWAN AND MACLAREN
INTERNATIONAL PTE LTD WHOSE CONSENT MUST BE SOUGHT BEFORE ANY USE OR REPRODUCTION
OF THE DRAWING OR ANY PART THEREOF CAN BE MADE
FILEPATH : O:\88.AR.M.12.SG016 CHINESE CULTURE ACADEMY\DRAWING\01 CAD\02 SHEETS\A20 EL\12-SG-016-A-23-001.dwg
SCALE DATE DRAWN BY CHECKED BY
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10
REV. NO.
KEYPLAN
NOTES / LEGEND
CONSULTANTS
PROJECT TITLE
SHEET INFORMATION
DRAWING NO.
EDUCATIONAL INSTITUTION DEVELOPMENT
TENDER DRAWINGS
PROPOSED ADDITION AND ALTERATION
TO FORMER CHAI CHEE SECONDARY
SCHOOL TO BE USED AS CHINESE
CULTURAL ACADEMY ON LOT 3965T-PT MK
27 AT 5 SENNETT ROAD
(BEDOK PLANNING AREA)
www.alpha.com.sg
2 Bukit Merah Central #16-00 Spring Singapore
Singapore 159835
18 Cross Street #15-06 China Square Central
Singapore 048423
www.wtpartnership.com
10 Anson Road #28-14 International Plaza
Singapore 079903
SMI LCB
ADDENDUM-1
DESCRIPTIONSREV. DATE
REVISION
NO.
LEGEND REVISED1. 29.11.2012
DOOR & WINDOW NOS REVISED 29.11.2012
29 NOV 2012
(NOT TO SCALE)
PROPOSED ADMIN BLOCK -
ELEVATIONS 13 & 14
12-SG-016-A-23-001
1:100 @ A1 29/11/2012
01
MA
TC
HLIN
E
MA
TC
HLIN
E
10
SCALE 1:100 (A1 SIZE)
5210
1
NEW EXTERNAL WALL BUILD UP TO BE :
'LAFARGE' OR EQUIVALENT APPROVED 'GTEC' INSULATED
EXTERNAL WALLING SYSTEM COMPRISING (FROM OUTSIDE) :
ACRYLIC RENDER ON MESH ON RENDER CARRIER BOARD ON
SUPPORT RAIL ON RIGID INSULATION ON STRUCTURAL FRAMED
STUD WITH MINERAL WOOL INSULATION BETWEEN STUDS.
PLASTERBOARD FINISH INTERNALLY.
1a
PROPOSED NEW OPENABLE ALUMINIUM WINDOW.
(REFER TO WINDOW SCHEDULE)
2
NEW 2.25M HIGH TIMBER SOLID CORE EXTERNAL DOOR WITH
PAINT FINISH. (REFER TO DOOR SCHEDULE)
3
EXISTING HANDRAILS TO BE RETAINED + RAISED IN HEIGHT TO A
MIN. OF 1000MM ABOVE EXISTING CONCRETE UPSTAND IN
ACCORDANCE WITH TYPICAL DETAILS DRAWING A-56-001
4
MAKE GOOD EXISTING PARTITION WALLS. PLASTERBOARD
FINISH ON BOTH SIDES.
SELF CLOSING FIRE DOOR.
RETAIN AND MAKE GOOD EXISTING ROLLER SHUTTER.
31
1.2MM PVC NURAPLAN 12 WATERPROOFING MEMBRANE OR
EQUIVALENT APPROVED ON SEPARATING LAYER ON RIGID
INSULATION ON METAL DECK TO FALLS.
34
EXISTING ASBESTOS ROOF TO BE REMOVED BY SPECIALIST IN
ACCORDANCE WITH 'GUIDELINES ON THE REMOVAL OF
ASBESTOS MATERIALS IN BUILDINGS' BY THE OCCUPATIONAL
SAFETY + HEALTH DIVISION - MINISTRY OF MANPOWER,
SINGAPORE
REPLACE WITH :
0.47MM THICK COLORBOND LYCORRIB STEEL ROOFING DECK OR
EQUIVALENT APPROVED ON 1.5MM THICK BITUMEN FELT ON
100x32 K/M² FIBERGLASS ON PARSEC HERMOBRITE 3 ALUMINIUM
FOIL OR EQUIVALENT APPROVED ON STEEL ROOF PURLINS ON
EXISTING ROOF TRUSSES TO ENGINEERS APPROVAL. ALL
SOFFITS, EAVES, RIDGES, FLASHINGS AND VERGES IN
ALUMINIUM.
11 PROPOSED LOCATION OF THE NEW LIFT.
12 PROPOSED NEW COVERED RC FOOTPATH.
13
14 NEW 1.2M HIGH BRICK WALL
32
EXISTING DEFECTIVE SKYLIGHT TO BE REMOVED. OPENING TO
BE INFILLED WITH SUITABLE MATERIAL.
33
EXISTING FLAT ROOF TO BE MADE GOOD USING TRAFFIGARD
LIQUID APPLIED ACRYLIC WATERPROOFING SYSTEM FOR
EXPOSED APPLICATION COMPRISING :
1 COAT PRIMER
2 COATS BODYCOAT WITH FIBERGLASS REINFORCEMENT
1 COAT TRAFFIGARD TOPCOAT
5
PROPOSED NEW R.C. STAIRCASE.6
PROPOSED NEW STEPS, 5 No. EQUAL RISERS.7
8
9
15PROPOSED RC WALL.
16CREATE 2.5M HIGH NEW OPENING IN THE WALL.
17NEW 1.8M HIGH FENCE.
RETAIN AND MAKE GOOD EXISTING GLASS LOUVERS.
14a NEW 2.25M HIGH BRICK WALL
14b NEW 3M HIGH BRICK WALL.
10
18 RECESSED MATWELL.
20 NEW RAMP (1:12 RAMP GRADIENT).
21
BUILD UP NEW WALL ABOVE WINDOWS (FROM OUTSIDE) :
NEW VERTICAL CORRUGATED & COATED STEEL SHEETING
(LYCORRIB 35 OR EQUIVALENT APPROVED.
COLOUR TO MATCH THE EXISTING)
ON WALL PURLINS WITH MINERAL WOOL INSULATION BETWEEN.
INTERNAL FINISH TO BE ACOUSTIC PERFORATED
PLASTERBOARD.
22
MAKE WATERTIGHT AND RETAIN EXISTING ALUMINIUM CLADDING
PANELS. INSULATE WALL INTERNALLY WITH MINERAL WOOL.
NEW ACOUSTIC PERFORATED PLASTERBOARD FINISH
INTERNALLY.
23
NEW 100MM TIMBER STUD PARTITION WALLS. PLASTERBOARD
FINISH ON BOTH SIDES.
19
24
NEW VERTICAL COLOURED ALUMINIUM BOX SECTION FEATURE
SCREEN WITH INTERMITTENT TIMBER LOUVERS.
EXISTING TIMBER BOARDED WALL TO BE RETAINED AND MADE
GOOD.
26
PROVIDE NEW STEEL BOX SECTION STRUCTURE FOR PROPOSED
COVERED WALKWAY.
25
NEW OPENABLE ALUMINIUM WINDOW.
PROPOSED RC FEATURE WALL.
NEW OPENING WITH ROLLER SHUTTER DOOR.35
NEW STEEL COLUMN TO SUPPORT NEW ROOF TO PROPOSED
NEW STAIRS.
36RETAIN AND MAKE GOOD EXISTING ALUMINIUM WINDOWS.
LEGEND:
37RETAIN EXISTING OPENING.
38
39
EXISTING ALUMINIUM LOUVRED SUNSHADE DEVICE STEEL /
CONCRETE STRUCTURE TO BE RETAINED AND MADE GOOD.
MISSING / DEFECTIVE ELEMENTS TO BE REPLACED TO MATCH
EXISTING.
THIS WINDOW IS PART OF A PROTECTED
EXTERNAL EXIT PASSAGEWAY.
WINDOW CILL LEVEL SHALL NOT BE BELOW
1.8M MEASURED FROM F.F.L. INSIDE.
NOTE:
ON NO ACCOUNT MAY THIS DRAWING BE SCALED.
ANY DISCREPANCY IN FIGURED DIMENSIONS (OR OTHERWISE
DISCREPANCIES BETWEEN ARCHITECTURAL/STRUCTURAL AND
MECHCANICAL/ELECTRICAL DRAWINGS) IS TO BE REPORTED
IMMEDIATELY TO THE ARCHITECTS BEFORE COMMENCEMENT OF
WORKS.
CONTRACTOR TO VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING WORK.
FIGURED DIMENSIONS GIVEN ARE TO BE TAKEN IN PREFERENCE TO
SCALING.
PL+104.285
GR
EE
N B
UF
FE
R
BU
IL
DIN
G S
ET
B
AC
K
PL+104.10
34
3
1
A
COPYRIGHT @ 2011, SWAN AND MACLAREN INTERNATIONAL PTE LTD
Internet: www.swanmaclaren.com
158 Cecil Street #06-01
Singapore 069545
THE OWNERSHIP OF THE COPYRIGHT IN THIS DRAWING IS RETAINED BY SWAN AND MACLAREN
INTERNATIONAL PTE LTD WHOSE CONSENT MUST BE SOUGHT BEFORE ANY USE OR REPRODUCTION
OF THE DRAWING OR ANY PART THEREOF CAN BE MADE
FILEPATH : O:\88.AR.M.12.SG016 CHINESE CULTURE ACADEMY\DRAWING\01 CAD\02 SHEETS\A20 EL\12-SG-016-A-23-002.dwg
SCALE DATE DRAWN BY CHECKED BY
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10
REV. NO.
KEYPLAN
NOTES / LEGEND
CONSULTANTS
PROJECT TITLE
SHEET INFORMATION
DRAWING NO.
EDUCATIONAL INSTITUTION DEVELOPMENT
TENDER DRAWINGS
PROPOSED ADDITION AND ALTERATION
TO FORMER CHAI CHEE SECONDARY
SCHOOL TO BE USED AS CHINESE
CULTURAL ACADEMY ON LOT 3965T-PT MK
27 AT 5 SENNETT ROAD
(BEDOK PLANNING AREA)
www.alpha.com.sg
2 Bukit Merah Central #16-00 Spring Singapore
Singapore 159835
18 Cross Street #15-06 China Square Central
Singapore 048423
www.wtpartnership.com
10 Anson Road #28-14 International Plaza
Singapore 079903
SMI LCB
ADDENDUM-1
DESCRIPTIONSREV. DATE
REVISION
NO.
LEGEND REVISED1. 29.11.2012
DOOR & WINDOW NOS REVISED 29.11.2012
29 NOV 2012
(NOT TO SCALE)
PROPOSED ADMIN BLOCK -
ELEVATIONS 15 & 16
12-SG-016-A-23-002
1:100 @ A1 29/11/2012
01
10
SCALE 1:100 (A1 SIZE)
5210
1
NEW EXTERNAL WALL BUILD UP TO BE :
'LAFARGE' OR EQUIVALENT APPROVED 'GTEC' INSULATED
EXTERNAL WALLING SYSTEM COMPRISING (FROM OUTSIDE) :
ACRYLIC RENDER ON MESH ON RENDER CARRIER BOARD ON
SUPPORT RAIL ON RIGID INSULATION ON STRUCTURAL FRAMED
STUD WITH MINERAL WOOL INSULATION BETWEEN STUDS.
PLASTERBOARD FINISH INTERNALLY.
1a
PROPOSED NEW OPENABLE ALUMINIUM WINDOW.
(REFER TO WINDOW SCHEDULE)
2
NEW 2.25M HIGH TIMBER SOLID CORE EXTERNAL DOOR WITH
PAINT FINISH. (REFER TO DOOR SCHEDULE)
3
EXISTING HANDRAILS TO BE RETAINED + RAISED IN HEIGHT TO A
MIN. OF 1000MM ABOVE EXISTING CONCRETE UPSTAND IN
ACCORDANCE WITH TYPICAL DETAILS DRAWING A-56-001
4
MAKE GOOD EXISTING PARTITION WALLS. PLASTERBOARD
FINISH ON BOTH SIDES.
SELF CLOSING FIRE DOOR.
RETAIN AND MAKE GOOD EXISTING ROLLER SHUTTER.
31
1.2MM PVC NURAPLAN 12 WATERPROOFING MEMBRANE OR
EQUIVALENT APPROVED ON SEPARATING LAYER ON RIGID
INSULATION ON METAL DECK TO FALLS.
34
EXISTING ASBESTOS ROOF TO BE REMOVED BY SPECIALIST IN
ACCORDANCE WITH 'GUIDELINES ON THE REMOVAL OF
ASBESTOS MATERIALS IN BUILDINGS' BY THE OCCUPATIONAL
SAFETY + HEALTH DIVISION - MINISTRY OF MANPOWER,
SINGAPORE
REPLACE WITH :
0.47MM THICK COLORBOND LYCORRIB STEEL ROOFING DECK OR
EQUIVALENT APPROVED ON 1.5MM THICK BITUMEN FELT ON
100x32 K/M² FIBERGLASS ON PARSEC HERMOBRITE 3 ALUMINIUM
FOIL OR EQUIVALENT APPROVED ON STEEL ROOF PURLINS ON
EXISTING ROOF TRUSSES TO ENGINEERS APPROVAL. ALL
SOFFITS, EAVES, RIDGES, FLASHINGS AND VERGES IN
ALUMINIUM.
11 PROPOSED LOCATION OF THE NEW LIFT.
12 PROPOSED NEW COVERED RC FOOTPATH.
13
14 NEW 1.2M HIGH BRICK WALL
32
EXISTING DEFECTIVE SKYLIGHT TO BE REMOVED. OPENING TO
BE INFILLED WITH SUITABLE MATERIAL.
33
EXISTING FLAT ROOF TO BE MADE GOOD USING TRAFFIGARD
LIQUID APPLIED ACRYLIC WATERPROOFING SYSTEM FOR
EXPOSED APPLICATION COMPRISING :
1 COAT PRIMER
2 COATS BODYCOAT WITH FIBERGLASS REINFORCEMENT
1 COAT TRAFFIGARD TOPCOAT
5
PROPOSED NEW R.C. STAIRCASE.6
PROPOSED NEW STEPS, 5 No. EQUAL RISERS.7
8
9
15PROPOSED RC WALL.
16
CREATE 2.5M HIGH NEW OPENING IN THE WALL.
17NEW 1.8M HIGH FENCE.
RETAIN AND MAKE GOOD EXISTING GLASS LOUVERS.
14a NEW 2.25M HIGH BRICK WALL
14b NEW 3M HIGH BRICK WALL.
10
18 RECESSED MATWELL.
20 NEW RAMP (1:12 RAMP GRADIENT).
21
BUILD UP NEW WALL ABOVE WINDOWS (FROM OUTSIDE) :
NEW VERTICAL CORRUGATED & COATED STEEL SHEETING
(LYCORRIB 35 OR EQUIVALENT APPROVED.
COLOUR TO MATCH THE EXISTING)
ON WALL PURLINS WITH MINERAL WOOL INSULATION BETWEEN.
INTERNAL FINISH TO BE ACOUSTIC PERFORATED
PLASTERBOARD.
22
MAKE WATERTIGHT AND RETAIN EXISTING ALUMINIUM CLADDING
PANELS. INSULATE WALL INTERNALLY WITH MINERAL WOOL.
NEW ACOUSTIC PERFORATED PLASTERBOARD FINISH
INTERNALLY.
23
NEW 100MM TIMBER STUD PARTITION WALLS. PLASTERBOARD
FINISH ON BOTH SIDES.
19
24
NEW VERTICAL COLOURED ALUMINIUM BOX SECTION FEATURE
SCREEN WITH INTERMITTENT TIMBER LOUVERS.
EXISTING TIMBER BOARDED WALL TO BE RETAINED AND MADE
GOOD.
26
PROVIDE NEW STEEL BOX SECTION STRUCTURE FOR PROPOSED
COVERED WALKWAY.
25
NEW OPENABLE ALUMINIUM WINDOW.
PROPOSED RC FEATURE WALL.
NEW OPENING WITH ROLLER SHUTTER DOOR.35
NEW STEEL COLUMN TO SUPPORT NEW ROOF TO PROPOSED
NEW STAIRS.
36RETAIN AND MAKE GOOD EXISTING ALUMINIUM WINDOWS.
LEGEND:
37RETAIN EXISTING OPENING.
38
39
EXISTING ALUMINIUM LOUVRED SUNSHADE DEVICE STEEL /
CONCRETE STRUCTURE TO BE RETAINED AND MADE GOOD.
MISSING / DEFECTIVE ELEMENTS TO BE REPLACED TO MATCH
EXISTING.
THIS WINDOW IS PART OF A PROTECTED
EXTERNAL EXIT PASSAGEWAY.
WINDOW CILL LEVEL SHALL NOT BE BELOW
1.8M MEASURED FROM F.F.L. INSIDE.
NOTE:
ON NO ACCOUNT MAY THIS DRAWING BE SCALED.
ANY DISCREPANCY IN FIGURED DIMENSIONS (OR OTHERWISE
DISCREPANCIES BETWEEN ARCHITECTURAL/STRUCTURAL AND
MECHCANICAL/ELECTRICAL DRAWINGS) IS TO BE REPORTED
IMMEDIATELY TO THE ARCHITECTS BEFORE COMMENCEMENT OF
WORKS.
CONTRACTOR TO VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING WORK.
FIGURED DIMENSIONS GIVEN ARE TO BE TAKEN IN PREFERENCE TO