BRINGING you quality and affordable Aesthetic & Medical Lasers
ST@RLIGHT --Co2 Fractional Laser
Co2 Fractional Laser
· Acne scars
· Actenic keratoses
· Skin cut: for warts removal, naevus removal, acrochordon removal,
polypus removal
· Basal cell carcinoma
· Burn debridement
· Laser skin resurfacing
· Eliminate the scar: Traumatism, operation
· Improve texture tone and pore size
· Erase unwanted brown spots
· Smooth wrinkles around the eyes and mouth
· Rejuvenate your neck, chest and hands etc
·Skin Whitening & Tightening, wrinkle Removal
·Pore shrinking
·Striae Gravidarum Removal, Tone &Texture Improvement
·Syringoma and Steatoadenoma Removal
·Treatment of Actinic keratoses & Seborrheic keratosis
Machine "Hybrid" constructionAdvantages
• 1) Modular design, allows ease of servicing
• 2) Metal frame for durability & stability
• 3) Shielded power supply
• 4) Available in 30w / 60W Metal RF Tube laser
generator made in USA (Access laser Co.).
laser lifetime performs longer• 5) Higher accuracy & Stability per shot
Our "RF" tube eliminates the need for gas refill when exhausted, for ease of maintenance and service
• 6) Fast treatment: Super treatment area andhigh pulse energy can enable you to treat anentire face in as little as 10 minutes
• 7) Micro single DOT: Minimum 120 micronssmall spot size ensures deeper penetration
• 8) Customize treatment: Control the pattern,density and energy easily, offer the flexiblepossibilities of treatments
• 9) Cost -effective: 5 years warranty for RFexcited CO2 laser tube, no consumables,offers immediate return on your investment
• 10) Fractional scanner pattern size and shape
• 11) Ablative burn area for the treatment ofsmaller areas
Picture after Treatment
Articulating Arm & Heads
The articulating arm comes with 3 types and head sizes to fit your various applications and procedures
3 heads to choose from (included in your purchase)
Scanner : Diameter: 50.8mm, 63.5mm
Scanning size: Maximum 20*20mm
Cutting surgery head: 100mm Diameter
Technical specification
Laser
wavelength
10600nm Graphic area ≤ 20mm × 20mm
Wavelength of
the target
635 nm Mode of Spot single-mode
Power of Target
optical
≤ 5mw Operation Intermittent and
continuous work
Diameter of
Focal spot
0.25mm Scan mode switching: order,
disorder, parallel
Area of Focal
spot
0.05mm2 Refrigeration
system
Air-cooled
Output Power ≤30W
(≤60W for option )
Optical system 7 articulated arms
Operating
voltage
AC 220V, 110V ±10%, 50Hz
Output mode Super-pulse dot-
matrix
Net weight 50Kg/110 lbs. Gross weight 98kg/216.03 lbs.
Output graphic triangle / square / rectangle / circle/ Oval / hexagon / linear
(scalable)
Ø Patient eye shield, Laser Safety goggles, carrying case andmicrofiber cloth
Included in your purchase
Machine Standard & Key Features
Energency switch Key switch Display Handle
*Healing zone selection to match each patient needs
*Leave 95% to 0% intact
Different patterns & shapes for you to chose from
OPTIONAL Treatment head for Vaginal Rejuvenation & Tightening
Screen operation
• It is fractional button, click here enter fractional pattern interface.
•
•
•
For normal mode button, click enter pulse mode interface.
Settings button, click to enter setup interface.
For system information button, click enter button into system information interface.
• Using parameters button adjust, control laser output power is 0-30W.
• Using parameters button adjustment, control the laser action time from 0.1 ms to 10ms in each point of during the scanning process
Fractional interface
• Using parameters button adjustment, between point and next point control thescanning clearance time 1-5000ms during the scanning process.
• Using parameter adjustment, control the distance of fractional points betweenpoints 0.1-2.6 mm, has reached purpose of control dot matrix density.
• Using parameter adjustment, control fractional scanning way divided into threetypes: scanning spots from one side to another side.
Random sequence modes: scanning spot without order, random.
Parting mode: scanning spot with counterpart next scanning point keep fractional distanceis one half.
• Using parameter adjustment for control the fractional scanning number (1-20th).
• Press 1-5 for the choice of digital storage space. Press save issave all the parameters in current page to change in the space, when using can alwayspress numeric button adjust.
Skin Resurfacing
• Using up and down add and subtract button adjust fractionalgraphics fluctuation in the direction of the largest Length is 0-20mm.
• Use for choose to scan graphics.
• After adjusting parameters, press ready button, then aim the scanner on the target area and ,press down on the foot pedal to activate scanner and fire laser.
• Click to return to main boundary.
To achieve best results, follow these steps
Normal interface
Selecting the POWER button, controls the laser output power for 0-30W or 0-60w (depending on your model purchase)
The MODE parameter adjustment, controls scanning and selectable in 3 modes
1. Single mode: trample down pedal switch after only launch a laser.
Duration range is 1-100ms.
2. Continuous mode: Fires the laser at a continuous rate with steady output3. Pulse mode: Fires the laser in pulse mode set by user which achieves
higher peak outputs
By pressing ready, the safety shutter is activated and shoots the laser with press of the footpedal
Click to return to main interface.
Controls depth and penetration of laser
Acts as a delay between laser being fired in seconds or microseconds
Treatment advantages
• Match patient needs to results
– Select healing zone volume (Density)
– Select volume treated (Spot Size)
– Select target depth (Epidermal or Dermal)
• Immediate results
– Removal of damaged skin
– Contracture via heat & ablation
• Continued long-term improvement
– Collagen remodeling and
Neocollagenesis
Select target depth (Epidermal or Dermal)
Scan Depth:20um-2000um adjustable
Before & After
Laser effect on the skin
After treatment (1 min)
Before treatment
After treatment
10 mins later
1
Before treatment
2
The first day
after treatment
3
The fourth day
after treatment
4
The 20th day
after treatment
Before treatment after 1st treatment after 2nd treatment
GAIN NOTICEABLE RESULTS ON THE FIRST TREATMENT
OPTIONAL Vaginal Treatment head
Scan and Cutting Heads
Working theory (Vaginal tightening & Rejuvenation)
Using an articulating arm probe with 360 rotation, and applying 50-70℃ heat at a controlled depth inside the vaginal mucosa - stimulates collagen contraction, restructuring and regeneration; promotes collagen fiber proliferating, remodeling; improves vaginal mucosa microcirculation; increases cell secretion and dynamic reaction function; corrects PH value of vaginal internals; thereby improving tissue elasticity. The result is a rejuvenated and restored vagina for a renewed patients improved sexual life and satisfaction.
Applications:1.Removes all kinds of wrinkles (brow veins, glabellas veins, neck veins, pregnancy veins and so on)
2.Strengthen, tighten skin, face promotion, Skin rejuvenation
3.Age spots and blemishes, acne and speckle treatment: blain acne, scabby acne, allergic acne, papilla acne, improving the appearance of liquidic skin and acne pit.
4.Treat telangiectasis
5.Repair of sun damaged skin on the face, neck, shoulders and hands
6.Skin excrescence, such as wart, etc.
7.Vaginal tightening
Contraction
Before and After
Certifications
ISO9001:2008
ISO13485:2003
Two models to choose from:
Starlight 30 - 30 Watts
Starlight 60 - 60 Watts
Options:Vaginal Tightening Attachment
Contact your dealer for more details
For product inquiry & sales Contact your Dealers belowBiomed Specialty Group, LLC 866-31-LASERContact: Maui or KenManufacturer website: novuslase.net, novuslase.com
We provide training, service, warranty included in your purchase.