Post on 03-Aug-2015
transcript
AKE BTU Measurement System
AKE BTU Measurement System
SHARING INNOVATIVE TECHNOLOGY
AKE BTU Measurement System
Content
Company profile
Certification
Market Background
BTU Measurement System
Market and Typical Cases
ContentsContents
AKE BTU Measurement System
Part I: Company Profile
Founded in 1997
Main Products: BTU Measurement System & Parking Guidance System
Certificates: ISO9001:2008
Over 700 projects in China
Independent Intellectual Property Right
6 patents
AKE BTU Measurement System
Part I: Company Profile
Milestone and honors:
In 1997, AKE is establishedIn 1998, the first generation of AKE BTU Measurement System was developed;In 1999, the first project was installed and put into practice (1st project in China); In 2000, obtained the first national patent in China;In 2001, obtained the “Innovation and Technology Fund” from Guangdong;In 2002, AKE products were chosen as the key new product in Guangdong;In 2003, obtained the progress prize in science and technology of Foshan;In 2004, obtained the “Innovation and Technology Fund” again;In 2005, passed ISO9001 Quality Management System;In 2006, obtained the hi-tech enterprises of Guangdong, named “Construction technological innovation superior enterprise”;In 2007, obtained “Annual energy-saving influential enterprises” (Construction);In 2008, obtained the patent prize of Foshan; obtained the certification of hi-tech enterprise of Guangdong;In 2009, obtained CE certification for partial products;In 2009, nominated as the chief drafting organization to compile National Time-based BTU Measurement System standard.
AKE BTU Measurement System
Part I: Company Profile
Focus AKEFocus AKESociety
Media Media
GovernmentGovernment
After twelve years developing, AKE puts the heart into BTU Measurement System
manufacture, research and development, makes a significant contribution to the
energy-saving emission, gets more and more attention from different field.
AKE BTU Measurement System
Part I: Company ProfileGovernment
19th, Sep, 2009 Mr.Yang Wang (Secretary of Guangdong province)
AKE BTU Measurement System
Part I: Company ProfileGovernment
Ministry of Industry & Information Mr.Baoqing Dong (Sub-director)
AKE BTU Measurement System
Part I: Company Profile
Expert Mr. Wu Yuanwei (HVAC fileld)
HVAC field
AKE BTU Measurement System
Part I: Company Profile
Technical conference
HVAC field
AKE BTU Measurement System
Part II: Certification
AKE BTU Measurement System
Part II: Certification
Famous brand High-tech enterprise
Patent Influential enterprise
AKE BTU Measurement System
Part II: Certification
Patent Production licence
Dominant enterprise High-tech products Certificate of metering guarantee
AKE BTU Measurement System
Part III: Background
Along with the fast growth of economics, chilled water system is widelyused. In the past, the consumer was simple paid by area shared, whether they used it or not, they must pay the same air conditioning fee, so it wouldcause a lot of disputes between owner and user.
To a certain extent this method wasted enormous energy. So, how tocharge the energy consumption billing for chilled water system became abig problem for the building owner.
AKE developed the first generation of BTU measurement system in 1998 which provide an scientific and reasonable charging basis and solved this problem excellently. It leads people to establish correct consumed habit tosave energy consciously and have yielded remarkable social and economic benefits.
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Energy-based metering Principle: Calculates the flow rate and temperature of supply and return water, based on heat transmission formula to calculate the energy consumption;
◆Time-based metering Principle: Calculates the efficient running time of high/middle/low speed, changes the total running time into an equivalent time, treats total equivalent time as user’s running time, finally as per rated unit price ($/hrs) to calculate the total fee.
AKE BTU Measurement System
System diagram
Part IV: BTU Measurement System
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Energy-based Metering
Principle and working processThe BTU meter real-time monitors the temperature of water return & supply bytemperature sensor PT1000, monitors the flow rate by flowmeter. According to Heat Transmission formula to integrate the cooling or heating consumption. Finally as per rated unit price (Dollars/MW) to calculate the total energy consumption of each users.
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Energy-based Metering
Heat Transmission Formula
Notes: Q: The volume of energy consumption ( unit: J or wh) qm: Unit weight of water passed by flowmeter (unit: kg/h) qv: Unit volume of water passed by flowmeter (unit:m3/h) ρ: Density of water (unit: kg/ m3) Δh: Enthalpy of water (unit: J/kg) Γ:Time (unit: h)
AKE BTU Measurement System
◆Energy-based Metering
System composition:
Top layer: PC and Printer Second layer: J02 Data Converter Third layer: G04P Data Manager Four layer: C03P BTU Meter, Electromagnetic flowmeter Temperature sensor PT1000
Part IV: BTU Measurement System
AKE BTU Measurement System
Part IV: BTU Measurement System
Brief description:
C03P BTU meter is the key device in this system, it collects the data from
temperature sensor and flowmeter, basing on Heat Transmission principle the
system automatically integrates energy consumption and transfers it to PC.
Could be checked consumption volume by user or operator, real time shows
temperature, flow rate and energy
consumption. etc., meanwhile it has the
ability to show history data with bar chart.
Partial products -- C03P BTU Meter
AKE BTU Measurement System
Partial products– C03P
Characteristics: Large LCD screen, total 4 rows display in each page;
Accuracy class: Class 2, Environment class: Class A
Shows historic data with bar chart by every day/month/year;
Multi-password prevents data missing or being revising;
Current input (4-20mA) and pulse input(0-200Hz) are compatible;
Modbus protocol based on RS485 communication;
Adopts photo-coupler , good anti-interference performance;
Programmable minimal flow can be ignored;
Secures storage, stores data automatically once power is cut off;
Remote alarm and clock function, remotely revises clock periodically;
Data output interface, can be integrated into Auto Meter Reading system;
Part IV: BTU Measurement System
AKE BTU Measurement System
Partial products – Electromagnetic flowmeter
High accuracy;
No mechanical movement part,
long lifetime and maintenance free;
Model: Ducted type -- EMF8000
Inserted type – DWM2000
Part IV: BTU Measurement System
EMF8000
DWM2000
AKE BTU Measurement System
Pipe diameter : DN25-200;
Output signal:4-20mA;
Medium temp:- 40 ~180℃
Pressure grade: DN<100: 4Mpa
100≤DN<200: 1.6Mpa;
Accuracy: 0.5%;
Measured sensitivity: 0.1m/s;
Split designed, converter and sensor are separately mounted.
Ducted Electromagnetic Flowmeter – EMF8000
Part IV: BTU Measurement System
AKE BTU Measurement System
Pipe diameter : DN100-400;
Output signal:4-20mA;
Medium temp:-25-150℃
Pressure grade: 2.5Mpa;
Accuracy: 2%;
Conductivity:≥20uS/cm;
Protection grade: IP66;
Electronic part can be changed without discharging water.
Inserted Electromagnetic flowmeter – DWM2000
Part IV: BTU Measurement System
AKE BTU Measurement System
Characteristics
Degree of Accuracy: 1 mk;
Wide output signal and high sensitivity: 1 level higher than other thermometer;
Wide testing range and good stable performance, under low sensitivity situation,
keeps stability below 0.1℃;
4-wires, when the wire is extended, the testing result won’t be affected.
Partial products – 4-wires PT1000
Part IV: BTU Measurement System
With covers and sleeves protected, easy installation.
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Energy-based Metering
Characteristics & Application: High accuracy;
Calculates the energy consumption by actual using;
Considering cost performance, it is suitable for installing at
large squares (big water pipes), likes shopping mall, office, public area, etc.
AKE BTU Measurement System
Part IV: BTU Measurement System
Flow Meter Types
Flow meter
With mechanical movement parts Without mechanical movement parts
Duct type Turbine flow
meter
Inserted type Turbine flow
meter
Vortex flow meter
Electromagnetic flow meter
Ultrasonic flow meter
AKE BTU Measurement System
Part IV: BTU Measurement System
Ducted type turbine flow meter Including horizontal and vertical rotator. Need horizontal flange installation, Not the best
suit for HVAC chilled liquid usage, because of the not pure water environment, easily be block by the incrustant, need a lot of maintenance jobs because it adopts the rotator (mechanical movement parts), and greatly affect the flow testing results once the rotator is blocked.
Not recommended in HVAC liq
uids
AKE BTU Measurement System
Part IV: BTU Measurement System
Inserted type flow meter
Including strong magnetic, weak magnetic, and non magnetic types. Also not a best suit for HVAC liquids because of its not very pure water environment, easily incrustant and be easily blocked, wind-up, adsorption etc, the testing accuracy will be greatly affected after not a very long time usage.
Not recommended in HVAC liquids
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Energy-based Metering Project
This plaza is a high-class office, has two
buildings: north & south tower, total 196,000 m2;
North tower: total 33 floors
South tower: total 34 floors
Condition: Each floor will be hired by one user;
Application: Each floor installs a set of BTU
meter, besides installs a set of
BTU meter in the main pipe.
Guangzhou Poly International Plaza
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Energy-based Metering Project
Shanghai Youyou International Plaza
It was a super comprehensive plaza
including hotels, apartments, offices,
shops, restaurants and Chambers, etc,
total 210,000m2. Building I was a 5 star
hotel, building II was centralized offices,
apartments, and others.
Aiming to this large squares we selected
Energy-based metering system.
AKE BTU Measurement System
Part IV: BTU Measurement System
How to metering the small square?
AKE BTU Measurement System
Part IV: BTU Measurement System
It is a innovational idea created by AKE.
Principle: Installs a Data Collector to connect FCU and Motorized valve,
calculates efficient run-time of FCU at different gear position (H/M/L speed) and changes it into an equivalent time, treats total equivalent time as user’s running time, finally as per rated unit price ($/hrs) to calculate the total fee.
◆Time-based Metering
AKE BTU Measurement System
Part IV: BTU Measurement System
Chilled water system is cooling/heating
FCU works or not
Motorized valve is opened or not
System starts
Data Collector stores the efficient running time at H/M/L gear speed
Equivalent time = speed running time* gear coefficient * Coil coefficient
Yes
Yes
Yes
No
No
No
charge
No
◆Time-based Metering
Total fee= Equivalent time*Unit price
AKE BTU Measurement System
System composition:
Top layer: PC and Printer;
Second layer: J02 Data Converter
Third layer: G04 Data Manager
Four layer: Data Collector
◆Time-based Metering
Part IV: BTU Measurement System
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Time-based Metering
Top layer – J02 Data Converter
Takes the responsibility to transmit data and control whole system. All information are finished and passed by Data Converter, such as receives the indication from PC and transmits some data to PC.
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Time-based Metering
Third layer – G04P Data Manager
Matches with Data Collector or BTU Meter and manages them by group;
Downwards: Real-time communicates with Data Collector or BTU Meter
and monitors its running-status;
Upwards: Communicates with Data Converter, accepts indication from
Data Converter and uploads data;
Each G04P can be max loaded 64pcs device.
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Time-based Metering
Fourth layer – Data Collector
C02B Data Collector
C02T Data Collector
AKE BTU Measurement System
◆Time-based Metering
Part IV: BTU Measurement System
Fourth layer – C02B Data Collector
It is a data acquisition device which performs real-time to detect motorized valve and FCU status, calculates the running time of different fan speed. When the motorized valve is opened basic on air condition is cooling or heating and FCU is operated, C02B starts to calculate the running time of each gear positions.
Besides, it has a control function -- close valve.
AKE BTU Measurement System
Characteristic Cost-effective;
Low power consumption, stable and reliable data transmission;
Use socket connector (wires box), easily install and maintain;
Suitable for connecting with thermostat or three-speed switch;
Three-ways or two-ways valve.
◆Time-based Metering
Part IV: BTU Measurement System
Fourth layer – C02B Data Collector
AKE BTU Measurement System
Utilizes microcomputer technology, integrates the thermostat and BTU measurement function. Under certain condition (efficient running), C02T stores heating and cooling running time basic on different gear positions (H/M/L speed) and accumulates them automatically, shows the data via display.
Part IV: BTU Measurement System
Fourth layer – C02T Data Collector
◆Time-based Metering
AKE BTU Measurement System
Part IV: BTU Measurement System
Fourth layer – C02T Data Collector
Main function:
With the thermostat and metering function;
Cooling/Heating/Ventilation mode selectable, adjusts the fan speed at
High/Middle/Low automatically, temperature correction;
Remote control ON/OFF;
Far keyboard locked, prevents temperature and fan speed optionally adjust;
Realizes pre-paid function, 24hrs advanced remind if haven’t enough
balance in account, stopped service automatically;
Memory setting function;
Failure warning function.
Infrared ray remote control (available/optional).
AKE BTU Measurement System
Characteristics
Large LCD display, blue background;
Includes a thermostat;
Two kinds mode: C02-8B and C02-8C;
Consumer can check consumption by themselves;
Use relay, high dependability;
Split type, isolate high current & low current, safety.
Part IV: BTU Measurement System
◆Time-based Metering
C02T-8B C02T-8C
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Time-based Projects
Guangzhou Renfeng Mansion
It is a high class office, total 100,000m2,152.5 height,
42 floors;
Has total 1922 FCU, every floor had different users;
Application: Installed 1922 set C02T.
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Time-based Project
Nanjing Fuxin building
● Total: 42 floors● Covered area:87,000m2 ● FCU: 800 pcs● Installed at 2003
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Time based & Energy based Comprehensive Project
Hangzhou Longhill Hotel
•Time-based metering:600 set
•Energy-based metering:4 set
•Flowmeter mode: Inserted electromagnetic type
AKE BTU Measurement System
Part IV: BTU Measurement System
◆Time based & Energy based Comprehensive Project
Changsha Yunda International Plaza
Had two tower-style buildings, total 100,000m2.
Consisted of hotels, offices, apartments, bank,
brand shops, etc.
According to our suggestion, large squares
such as banks, shops and hotels adopted
Energy-based metering system, but the
offices, apartments whose terminals were
FCU adopted Time-based system.
AKE BTU Measurement System
Part V: Market & Typical case
East
South
South-west Middle
North
market occupancy:
Over 60%
China
market
AKE BTU Measurement System
Part V: Market & Typical case
i) South of China:
Guangzhou R&F Profit Plaza Guangzhou CITIC Plaza Foshan Global Plaza
Guangzhou Pazhou Poly Plaza Shenzhen Ocean Investment Center Guangzhou International Finance Centre
AKE BTU Measurement System
Part V: Market & Typical case
ii) East of China
Shanghai Henglong Plaza Shanghai Youyou International Plaza
Shanghai Golden Eagle Building Shanghai Grand Gateway Plaza
Shanghai Merrylin Hotel
AKE BTU Measurement System
Part V: Market & Typical case
iii) North of China
Institute of Zoology Chinese Academy of Sciences
Beijing Shunyi Industry Plaza
Beijing Zhongtie Plaza
Tianjin Jinwan Mansion
Chinese Academy of Engineering -academician office Zhengda apartment
AKE BTU Measurement System
Part V: Market & Typical case iv) Middle of China
CNC of Xinxiang Zhengzhou branch
Henan Xinxiang Victoria Plaza Changsha Yunda International Plaza
Anyang Sugarbush Mansion
China Everbright Bank-Henan branch
Wuhan Yinhai Huating Mansion
AKE BTU Measurement System
Part V: Market & Typical case
v) West-south of China
Chongqing Sheraton Hotel
Chongqing Changan Lidu Mansion Sichun Sky Building
Chongqing CITIC Bank Chongqin Days hotel
AKE BTU Measurement System
Website: www.ake.com.cn
SHARING INNOVATIVE TECHNOLOGY