Analysis and design of multystory building

Post on 19-Jan-2015

2,129 views 0 download

Tags:

description

a presentation about analysis and design of a multy-story building as hotel using hand calculating and programas of STAAD-pro and STA4-cad, it was done by microsoft office 2013.

transcript

UNIVERSITY OF SALAHADDIN COLLEGE OF ENGINEERINGCIVIL ENG.DEPARTMENT

Analysis and Design of a Multistory Reinforced Concrete Building

҉�Prepared by

Awat hasan amin Bashdar kazm ali

҉�superviser assist lecturer. Zrar Sedeeq

GRADUATION PROJECT

MULTI STORY BUILDING

OUTLINE

IntroductionObjectivesStructural Elementso Slabs• Slab supported with beams• Design of slab• Details of slab

o Beams• Design of beam• Details of beams

INTRODUCTIONo The project is a multi- storey building which is used for residential purpose as hotelo It consists of 6 stories (basement, ground.1st.2nd,3rd,4th,5th floors),o The basement which is 3m height use as store, o The ground floor which is 4m height use as reception and servicing ,o The other floors which is 3m height in this hotel use as sleep rooms for guests and

passengers.

OBJECTIVES

• Analysis and design of multi-story building including slabs,beams,columns,elevated wall and foundation.

1. Analysis and design of slab supported with beams by Direct design method and yield line method for cantilever and corner span.

2 . Analysis and design of beams by coeffi cient method.

3 . Analysis and design of columns and elevated wall.

4 . Analysis and design of foundation.

STRUCTURAL ELEMENTS

Slab Beam Column Foundation Elevated wall

TYPES OF SLAB

Slab

Two-way beam supported slab is our beam type

SLAB DESIGN

• Analysis and design by direct design method and yield line method for cantilever and corner panel.

• For the most critical span

Max -ve M @long dir = 18.17 kN.m

Max +ve M @long dir = 14.8 KN.m

Max -ve M @short dir = 5.835 kN.m

Max +ve M @short dir = 4.75 kN.m

SLAB DETAILS

e

fi

e

A B C D

6.206.40

3.70

6.40

1

3.651.80

2

3.70

3

3.70

4

5

3.70

61.80

3.65

7

ba

k k

BEAM

• Analysis and design by coefficient method (aci code 318-08.8.3.3)

• For the most critical beam

Max +ve M= 107.23 KN.m

Max -ve M= 145.15 KN.m

BEAM DETAILS

SHORT BEAMS• Interior beams

SHORT EXTERIOR BEAMS

LONG INTERIOR BEAMS

LONG EXTERIOR BEAMS

SOME ADDITIONAL WORKSCOMPUTER PROGRAMING

Analysis and design the exist slab and beam by sta4-cad v13 and staad-pro v8i

Note// this programing steps doesn’t included in our graduation projectWe just did it for more assurance that has been calculated by hand.

STAD4-CAD V13

Is a program which is used for analysisAnd design reinforced concrete structures

By direct design Max M long dir = 18.17 kN.m Max M short dir = 5.835 kN.m

By stad4-cad program Max M long dir = 19.71 kN.m Max M short dir = 6.58 kN.m

Differentiate of moments for the most critical span by both hand

Calculating and programming

SLAB DESIGN BY STA4-CAD V13

DETAIL OF SLAB BY STA4-CAD

STAAD.PRO V8

It is a program which is used for analysis and design of reinforced concrete structures

By coefficient method aci code 318-08.8.3.3

Max +ve M= 107.23 KN.m

Max -ve M= 145.15 KN.m

By stad pro program:

Max +ve M= 82.54 KN.m

Max –ve M= 130.97 KN.m

Differentiate of moments for the most critical beam by both

hand Calculating and programming

END