DESIGN TEAM
Martin/MartinME EngineersStudio Insite
Design BalanceAmbient Energy
WELCOME CENTERCOLORADO SCHOOL OF MINES GOLDEN, CO
MAY 2, 2014
100% CD SET
1
A101
SIM
A101
1SIM
BUILDING SECTIONREFERENCE
INTERIOR SECTIONDETAIL REFERENCE
CENTERLINE
ROOM IDENTIFICATION
3
24
1
A5.60
NORTH ARROW
W WINDOW NUMBER
11.44A
Room name101
150 SF
DOOR NUMBER
WRGB24' - 0"
100'-0"
EVENT LEVEL
100'-0"
ROOM NAMEROOM NUMBERROOM AREA
CEILING TAG
CEILING MATERIALCEILING HEIGHT
ELEVATION TAGS
SPOT ELEVATIONS
(FLOOR NAME)
(FLOOR ELEVATION)
##-#- -R1 1 A1
2
1
A4.30
SIM
WALL TYPERE: LEGEND ONSHEET A9.00
ENLARGED PLAN / DETAIL
DRAWING NUMBER
FLOOR ELEVATION
0GRID BUBBLES
GRID NUMBER
INTERIOR ELEVATIONSHEET NUMBER
DRAWING NUMBER
1
A101
SIM WALL SECTIONREFERENCE
9' - 4"
DIMENSIONALL PLAN DIMENSIONS ARE TO FACE OF STUDFRAMING OR FACE OF MASONRY UNLESSNOTED OTHERWISE
TS-01TOILET ACCESSORIES TAGSEE LEGEND ONSHEET A5.00
TG-W4 TOILET / SHOWER GROUPSEE LEGEND ONSHEET A5.00
EQ-69 EQUIPMENT TAGSEE SCHEDULE ONSHEET A0.10
? KEYNOTE
WALL TYPE EXTERIOR ASSEMBLY TAG
BRICK
CONCRETE BLOCK
CAST IN PLACECONCRETE
PRECAST CONCRETE
CAST STONE
CUT STONE
COMPACTED FILL
UNDISTURBED EARTH
GRAVEL
BATT INSULATION / SOUNDATTENUATION BLANKETS
RIGID INSULATION
WOOD BLOCKING
FINISH WOOD - CUT
STEEL
PLYWOOD/SHEATHING
ALUMINUM (LARGESCALE)
GYPSUM BOARD
ACOUSTICAL WALL PANEL
SAFP (SPRAY APPLIEDFIRE PROOFING)
PROJECT SITE
18TH ST.
19TH ST. ILLINOIS ST.
ELM ST.
17TH ST.
MAPLE ST.
US-6
ABBREVIATIONS
COLORADO SCHOOL OF MINES - WELCOME CENTERGOLDEN, COLORADO
LEGEND VICINITY MAPMATERIAL SYMBOLS
GENERAL NOTES
UNO UNLESS NOTED OTHERWISE
V
VACT VINYL COATED ACT
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VEN VENEER
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
W
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WND WINDOW
WP WORKING POINT
WR WATER RESISTANT
WRGB WATER RESISTANT GYPSUM BOARD
WT WEIGHT
WWF WELDED WIRE FABRIC
X
XS EXPOSED STRUCTURE
OFF OFFICE
OFOI OWNER FURNISHED, OWNERINSTALLED
OH OPPOSITE HAND
OPG OPENING
OPP OPPOSITE
OTO OUTSIDE-TO-OUTSIDE
OVHD OVERHEAD
P
PB PARTICAL BOARD
PC PRECAST CONCRETE
PER PERIMETER
PL PLATE
PLAM PLASTIC LAMINATE
PMW PREFINISHED METAL WALL PANEL
PNL PANEL(BOARD)
PNTD PAINTED
PR PAIR
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT PAINT
PTD PAPER TOWEL DISPENSER
PV PAVEMENT
PWR POWER
Q
Q QUADRANT
QT QUARRIED TILE
QTY QUANTITY
QUAD QUADRANT
R
R RADIUS / RISER
RA RETURN AIR
RB RUBBER BASE
RBF RUBBER FLOORING
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFER TO or REFERENCE
REC RECEPTACLE
REF REFERENCE
REINF REINFORCING
REQ REQUIRED
RESIL RESILIENT
REV REVISE, REVISED or REVISION
RM ROOM
RO ROUGH OPENING
ROD ROOF OVERFLOW DRAIN
ROW RIGHT OF WAY
RT RESILIENT TILE
RTG RATING
S
S SOUTH
SAN SANITARY
SC SOLID CORE
SCHD SCHEDULE
SECT SECTION
SF SQUARE FEET
SHT SHEET
SHTG SHEATHING
SHWR SHOWER
SIM SIMILAR
SPEC SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
SS SOLID SURFACE
ST STAINED
STBD STRAW BOARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE or STRUCTURAL
SVB SHEET VINYL BASE
SVF SHEET VINYL FLOORING
SYM SYMMETRICAL
SYS SYSTEM
T
T TILE
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TEL TELEPHONE
TEMP TEMPORARY
THK THICK or THICKNESS
TMPRD TEMPERED
TO TOP OF
TRANS TRANSFER
TV TELEVISION
TYP TYPICAL
U
UL UNDERWRITER'S LABORATORY
FHC FIRE HOSE CABINET
FIN FINISH(ED)
FL FLOOR(ING)
FLEX FLEXIBLE
FLUOR FLUORESCENT
FO FACE OF
FRP FIBER RESIN PANEL
FRTW FIRE RESISTANT TREATED WOOD
FS FLOOR SINK
FT FOOT/FEET
FTG FOOTING
FUT FUTURE
FV FIELD VERIFY
G
GA GAUGE
GALV GLAVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GL GLASS/ GLAZING
GRD GRID LINE
GYP GYPSUM BOARD
H
HB HOSE BIB
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
HTG HEATING
HVAC HEATING, VENTILATION and AIRCONDITIONING
I
IBC INTERNATIONAL BUILDING CODE orINSTALLED BY CONTRACTOR
ID INSIDE DIAMETER
IN INCH
INFO INFORMATION
INSUL INSULATION or INSULATED
INT INTERIOR
IRGB INPACT RESISTANT GYPSUM BOARD
J
JAN JANITOR
JB JUNCTION BOX
JT JOINT
K
KD KNOCKDOWN
KO KNOCKOUT
L
L LENGTH
LAM LAMINATE
LAV LAVATORY
LH LEFT HAND
LKR LOCKER
LL LIVE LOAD
LP LIGHTING PANEL
LT LIGHT
LTG LIGHTING
M
M MIRROR
MAS MASONRY
MAT MATERIAL
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL andPLUMBING
MFR MANUFACTURER
MID MID-POINT/MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
ML METAL LOCKERS
MO MASONRY OPENING
MT MOUNT(ED)
MTD MOUNTED
MTL METAL
N
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED, CONTRACTORINSTALLED
_
# POUND(S) or NUMBER
& AND
< ANGLE
@ AT
A
AB ANCHOR BOLT
ACM ALUMINUM COMPOSITE PANEL
ACT ACCOUSTICAL CEILING TILE
AD AREA DRAIN
ADA ACCESSIBLE
AF ATHLETIC FLOORING
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE(LY)
ARCH ARCHITECTURAL
ASI ARCHITECT'S SUPPLEMENTALINSTRUCTIONS
AUTO AUTOMATIC
B
BB BACKER BOARD
BD BOARD
BLDG BUILDING
BO BOTTOM OF
BP BUILDING PAPER
C
CATV CABLE TELEVISION
CB CARPET BASE
CBB CEMENTITIOUS BACKER BOARD
CCTV CLOSED CIRCUIT TELEVISION
CFCI CONTRACTOR FURNISH,CONTRACTOR INSTALL
CFMF COLD FORMED METAL FRAMING
CFOI CONTRACTOR FURNISH, OWNERINSTALL
CFT CERAMIC FLOOR TILE
CG CORNER GUARD
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACT(OR)
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTB CERAMIC TILE BASE
D
DBL DOUBLE
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DISCONT DISCONTINUOUS
DN DOWN
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
E
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATOR
EP EPOXY PAINT
EQ EQUAL/EQUIVALENT
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EX EXPOSED
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
F
FAA FIRE ALARM ANNUNCIATOR
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FINISHED FLOOR ELEVATION
FG FINISH GRADE
FH FIRE HYDRANT
All information appearing herein shall not be duplicated, discharged orotherwise used without the written consent of Sink Combs Dethlefs
Issues/Revisions: Date:
SCD Project No.:
10/16/13SCHEMATIC DESIGN
02/07/14DESIGN DEVELOPMENT
04/04/1480% CD SET / PERMIT SET
05/02/14100% CD SET
WELCOME CENTER
A0.01
LEGENDS &ABBREVIATIONS
COLORADO SCHOOL OF MINESGOLDEN, CO
1219
PROJECT TEAM
OWNER
COLORADO SCHOOL OF MINESCAPITAL PLANNING ANDCONSTRUCTION1318 MAPLE STREETGOLDEN, CO 80401PHONE: 303-384-2517CONTACT: SUSAN MINER
ARCHITECT
SINK COMBS DETHLEFS475 LINCOLN STREET, SUITE 100DENVER, CO 80203PHONE: 303-308-0200CONTACT: KEVIN ARMSTRONG
CIVIL ENGINEER
MARTIN / MARTIN12499 W. COLFAX AVENUELAKEWOOD, CO 80215PHONE: 303-431-6100CONTACT: SCOTT PALING
LANDSCAPE ARCHITECT
studioINSITE3457 RINGSBY COURT, UNIT 223DENVER, CO 80216PHONE: 303-433-7100CONTACT: CHRIS GEDDES
STRUCTURAL ENGINEER
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
SPECIFICATIONS
MARTIN / MARTIN12499 W. COLFAX AVENUELAKEWOOD, CO 80215PHONE: 303-431-6100CONTACT: JOHN BRUNNER
ME ENGINEERS10055 W. 43RD AVENUEWHEAT RIDGE, CO 80033PHONE: 303-421-6655CONTACT: LEONARD GURULE
JAMES MILLER1137 SHERMAN STREET #17DENVER, CO 80203(303) 475-0348
ME ENGINEERS10055 W. 43RD AVENUEWHEAT RIDGE, CO 80033PHONE: 303-421-6655CONTACT: ED HORNFECK
LEED CONSULTANT
DESIGN BALANCEP.O. BOX 7214MISSOULA, MT 59807(406) 721-7077CONTACT: KELLY KARMEL
ENERGY MODELING CONSULTANT
AMBIENT ENERGY130 W. 5TH AVENUEDENVER, CO 80203(303) 278-1532CONTACT: LINDA MORRISON
NORTH
NOT TO SCALE
I) EXPOSED AREA OF AN INDIVIDUAL PANE IS GREATER THAN 9 SQUARE FEET, AND;II) EXPOSED BOTTOM EDGE IS LESS THAN 18 INCHES ABOVE THE FLOOR, AND;III) EXPOSED TOP EDGE IS GREATER THAN 36 INCHES ABOVE THE FLOOR, AND;IV) ONE OR MORE WALKING SURFACES ARE WITHIN 36" HORIZONTALLY OF THE PLANEOF THE GLAZING.
A) FIXED AND SLIDING PANELS IN SWINGING DOORS.B) WINDOWS WITHIN 24" OF DOORS IN ANY POSITION NOT MORE THAN 60" ABOVEWALKING SURFACE.C) INDIVIDUAL FIXED OR OPERABLE PANELS, OTHER THAN THOSE LOCATIONSDESCRIBED ABOVE, THAT MEET ALL OF THE FOLLOWING CONDITIONS:
REFER TO CODE ANALYSIS REPORT FOR A LISTING OF APPLICABLE BUILDING CODES AND STANDARDS. ITSHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND RESPECTIVE SUBCONTRACTORS TOBUILD TO SATISFY THESE CODES AND CALL FOR ALL NECESSARY INSPECTIONS.
REFER TO PROJECT SPECIFICATIONS FOR FURTHER DEFINITION OF THE WORK.
THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE SITE AND REPORT ALL DISCREPANCIESTO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. CONTACT ARCHITECT FOR CLARIFICATION INTHE EVENT OF ANY DISCREPANCY IN THE CONSTRUCTION DOCUMENTS OR ANY AMBIGUITY OFARCHITECTURAL INTENT.
ALL LEGAL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIALKNOWLEDGE OR EFFORT.
ALL PLAN DIMENSIONS ARE TO CENTERLINE OF COLUMN GRID, FACE OF STUD FRAMING FACE OF CONCRETEOR FACE OF CMU UNLESS NOTED OTHERWISE.
THE LARGEST SCALE DRAWING SHALL GOVERN OVER ALL OTHER DRAWINGS.
"F.V." (FIELD VERIFICATION) OR "V.I.F."(VERFIY IN FIELD) ON DRAWINGS REFERS TO CONTRACTOR CHECKING ASPECIFIC AREA FOR CORRECT DIMENSIONS AND CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES.
DO NOT SCALE DRAWINGS
THE GENERAL CONTRACTOR SHALL PREP ALL FLOORS TO RECEIVE FINISHES.
PROVIDE BACKING PLATES IN WALL FOR ALL WALL MOUNTED EQUIPMENT AND CASEWORK AS INDICATED INTHE DRAWINGS.
COORDINATE DUCT, FLUE, AND VENT PENETRATIONS WITH MECHANICAL CONTRACTOR.
LOCATE ALL PLUMBING IN PROTECTED AREAS OR PROVIDE MEANS TO AVOID FREEZING OF PIPES AND TRAPS.
ALL ELEVATIONS SHOWN ON PLANS ARE BUILDING ELEVATIONS (MAIN LEVEL = 100'-0")
PAINT ALL INTERIOR CONDUIT, DUCTWORK, PIPING, ETC., IN FINISHED SPACES EXPOSED TO PUBLIC VIEW.
PAINT ALL EXPOSED METAL ON EXTERIOR OF BUILDING WITH HIGH PERFORMANCE PAINT SYSTEM THAT ISNOT INDICATED TO BE PREFINISHED U.N.O., INCLUDING BUT NOT LIMITED TO CONDUIT, PIPING, GAS PIPING,FLASHING, MECH. FLUES AND DUCTS, LINTELS, HOLLOW METAL FRAMING AND DOORS, STEEL, AND MECH.EQUIPMENT.
PROVIDE TRAPEZE TO SUPPORT SUSPENDED CEILINGS AS REQUIRED BELOW DUCTWORK OR OTHEROBSTRUCTIONS.
COORDINATE ALL WOOD BLOCKING AND SHEATHING WITH REQUIREMENTS OF THE IBC.
WALL AND CEILING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS LISTED IN THE IBC.
PROVIDE ACCESS PANELS AT LOCATIONS INDICATED AND AS REQUIRED FOR ACCESS TO EQUIPMENT ANDDEVICES INCLUDING, BUT NOT LIMITED TO MECHANICAL, PLUMBING, AND ELECTRICAL WORK.
PROVIDE AN ALLOWANCE FOR 50 CORNER GUARDS TO BE PLACED AT GYP. BD. WALL CORNER LOCATIONS.
PENETRATIONS OF FIRE-RESISTIVE WALLS, FLOOR-CEILINGS AND ROOF-CEILINGS SHALL BE PROTECTED ASREQUIRED IN THE IBC.
GLAZING IN THE FOLLOWING LOCATIONS SHOULD BE OF SAFETY GLAZING PER SECTION 2406.3 OF THE IBC.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23. PROVIDE FIRE EXTINGUISHERS AS INDICATED THUS ON THE DRAWINGS.
FE: INDICATES A FIRE EXTINGUISHER INSTALLED ON A WALL-MOUNTED BRACKET.
SHEET INDEX
A1.00 EXISTING SITE / DEMO PLAN & ARCHITECTURAL SITE PLAN
A2.10 BASEMENT & FIRST LEVEL FLOOR PLANS
A2.20 SECOND & THIRD LEVEL FLOOR PLANS
A2.30 ROOF LEVEL PLAN
A3.10 BUILDING ELEVATIONS
A3.11 BUILDING ELEVATIONS
A3.20 BUILDING SECTIONS
A3.21 BUILDING SECTIONS
A3.30 WALL SECTIONS
A3.31 WALL SECTIONS
A3.40 AERIAL ISOMETRICS
A4.10 ENLARGED PLANS & ELEVATIONS
A4.11 ENLARGED PLANS & ELEVATIONS
A4.12 ENLARGED PLANS & ELEVATIONS
A4.20 ENLARGED PLANS & ELEVATIONS
A4.30 ENLARGED PLANS & ELEVATIONS
A5.50 STANDARD MILLWORK DETAILS
A5.51 MILLWORK & RCP DETAILS
A6.10 BASEMENT & FIRST LEVEL REFELCTED CEILING PLANS
A6.20 SECOND & THIRD LEVEL REFELCTED CEILING PLANS
A7.10 STAIR & ELEVATOR PLANS & SECTIONS
A7.20 STAIR & LADDER DETAILS
A8.10 SITE, PLAN, & EXTERIOR WALL DETAILS
A8.20 EXTERIOR WALL DETAILS
A8.30 ROOF DETAILS
A9.00 WALL TYPES AND FRAMING NOTES
A9.01 PARTITION FRAMING CRITERIA
A9.02 CEILING DETAILS
A9.60 SIGNAGE SCHEDULE & DETAILS
A9.61 BASEMENT & FIRST LEVEL SIGNAGE PLANS
A9.62 SECOND & THIRD LEVEL SIGNAGE PLANS
A9.70 ROOM FINISH SCHEDULE & LEGEND
A9.71 BASEMENT & FIRST FLOOR FINISH PLANS
A9.72 SECOND & THIRD FLOOR FINISH PLANS
A9.80 DOOR SCHEDULE
A9.81 WINDOW ELEVATIONS
A9.82 WINDOW ELEVATIONS
A9.83 WINDOW & DOOR DETAILS
A9.84 WINDOW & DOOR DETAILS
A9.85 WINDOW & DOOR DETAILS
A9.86 WINDOW & DOOR DETAILS
A0.01 LEGENDS & ABBREVIATIONS
A0.10 CODE ANALYSIS
A0.11 CODE ANALYSIS PLANS
A0.12 CODE ANALYSIS PLANS
TITLE SHEET
CIVILC1.00 COVER SHEETC1.01 EXISTING CONDITIONS & DEMOLITION PLANC2.00 HORIZONTAL CONTROL PLANC3.00 EROSION CONTROL PLANC3.01 EROSION CONTROL DETAILSC4.00 GRADING PLANC5.00 STORM SEWER PLAN AND PROFILEC6.00 TUNNEL PLANC7.00 OVERALL UTILITY PLANC8.00 DETAIL SHEETC8.01 DETAIL SHEETC8.02 DETAIL SHEETC8.03 DETAIL SHEETC8.04 DETAIL SHEET
LANDSCAPELS1.00 OVERALL LANDSCAPE SITE PLANLS1.01 LANDSCAPE SITE PLANLS1.02 LANDSCAPE SITE PLANLS2.01 LANDSCAPE SITE LAYOUT ENLARGEMENTSLS4.01 LANDSCAPE DETAILSLS4.02 LANDSCAPE DETAILSLS4.03 LANDSCAPE DETAILSLP1.00 OVERALL LANDSCAPE PLANTING PLANLP1.01 LANDSCAPE PLANTING PLANLP1.02 LANDSCAPE PLANTING PLANLP4.01 PLANTING DETAILSIR1.00 OVERALL IRRIGATION SITE PLANIR1.01 IRRIGATION DETAILSIR1.02 IRRIGATION DETAILS
ARCHITECTURAL
STRUCTURALS0.01 NOTESS0.02 NOTESS2.10 BASEMENT & FIRST FLOOR LEVEL PLANSS2.20 SECOND FLOOR LEVEL & LOBBY ROOF PLANSS2.30 THIRD FLOOR LEVEL & ROOF LEVEL PLANSS2.40 ROOF SCREEN PLANS3.00 TYP CONCRETE DETAILSS3.10 TYP DRILLED PIER DETAILSS3.11 SITE WALL DETAILSS3.12 FOUNDATION WALL DETAILSS3.13 FOUNDATION DETAILSS3.15 TYP STEEL TO CONCRETE CONNECTIONSS3.16 TYP SLAB DETAILSS3.17 UTILITY TUNNEL DETAILSS3.20 CONCRETE WALL ELEVATIONSS3.21 CONCRETE WALL ELEVATIONSS3.22 WALL SECTIONSS5.00 TYP STEEL BEAM CONNSS5.01 TYP STEEL BEAM CONNSS5.02 TYP STEEL DETAILSS5.03 STEEL GIRT CONNSS5.30 TYP METAL DECK DETAILSS5.31 TYP METAL DECK DETAILSS5.40 TYP WALL DETAILSS5.41 WALL DETAILSS5.42 WALL DETAILSS5.43 WALL DETAILS
MECHANICAL / PLUMBINGM0.00 MECHANICAL LEGENDM0.01 MECHANICAL NOTESM2.10 BASEMENT & FIRST FLOOR MECHANICAL PLANSM2.20 SECOND & THIRD FLOOR MECHANICAL PLANSM2.30 ROOF LEVEL MECHANICAL PLANM3.10 BASEMENT & FIRST FLOOR PIPING PLANSM3.20 SECOND & THIRD FLOOR PIPING PLANSM3.30 ROOF LEVEL PIPING PLANM4.10 ENLARGED MECHANICAL PLANSM6.00 MECHANICAL SCHEMATICS AND CONTROL DIAGRAMSM6.01 MECHANICAL SCHEMATICS AND CONTROL DIAGRAMSM6.02 MECHANICAL SCHEMATICS AND CONTROL DIAGRAMSM8.01 MECHANICAL DETAILSM8.02 MECHANICAL DETAILSM8.03 MECHANICAL DETAILSMEP0.01 MECHANICAL SCHEDULESMEP0.02 MECHANICAL SCHEDULES
MP2.00 TUNNEL PIPING PLANMP3.00 TUNNEL ENLARGED PLANSMP3.01 TUNNEL ENLARGED PLANSP0.00 PLUMBING LEGEND AND NOTESP0.01 PLUMBING SCHEDULESP1.00 PLUMBING AND MECHANICAL SITE PLANP2.00 UNDERGROUND PLUMBING PLANP2.10 BASEMENT & FIRST FLOOR PLUMBING PLANSP2.20 SECOND & THIRD FLOOR PLUMBING PLANSP2.30 ROOF FLOOR PLUMBING PLANP2.40 PLUMBING ENLARGED PLANSP3.00 PLUMBING RISER DIAGRAMSP3.01 PLUMBING RISER DIAGRAMSP4.00 PLUMBING DETAILS
FP2.10 FIRE PROTECTION
ELECTRICALE0.01 ELECTRICAL LEGENDE0.02 ELECTRICAL ONE-LINEE0.03 LIGHTING FIXTURE SCHEDULEE0.04 ELECTRICAL PANEL SCHEDULESE0.05 ELECTRICAL PANEL SCHEDULESE0.06 ELECTRICAL PANEL SCHEDULESE1.00 SITE ELECTRICAL PLANE2.10 BASEMENT & FIRST LEVEL ELECTRICAL PLANSE2.20 SECOND & THIRD LEVEL ELECTRICAL PLANSE2.30 ROOF LEVEL ELECTRICAL PLANE3.00 SITE LIGHTING PLANE3.10 BASEMENT & FIRST LEVEL LIGHTING PLANSE3.20 SECOND & THIRD LEVEL LIGHTING PLANSE3.30 ROOF LEVEL LIGHTING PLANE4.10 BASEMENT & FIRST LEVEL FIRE ALARM PLANSE4.20 SECOND & THIRD LEVEL FIRE ALARM PLANSE4.30 ROOF LEVEL FIRE ALARM PLANE5.01 ELECTRICAL DETAILS
TECHNOLOGYT0.01 TECHNOLOGY LEGENDT0.02 TECHNOLOGY ONE-LINEST1.00 TECHNOLOGY SITE PLANT1.01 TECHNOLOGY CAMPUS PLANT2.10 BASEMENT & FIRST LEVEL FLOOR PLANT2.20 SECOND & THIRD LEVEL FLOOR PLANT2.30 ROOF LEVEL FLOOR PLANT3.01 TECHNOLOGY TYPICAL ENLARGED ROOM PLANT4.01 TECHNOLOGY DETAILST4.02 TECHNOLOGY DETAILS
ADD ALTERNATES SCHEDULEALTERNATE 1: PROVIDE WOOD PANELING AS SHOWN IN DRAWINGS
LOCATED IN LOBBY 100, LOBBY 107, HERITAGE LOUNGE 108 & HALL C110ALTERNATE 2: CONCRETE SEAT WALL AT NORTH PLAZA IDENTIFIED ON LS1.01ALTERNATE 3: PROVIDE TRASH ENCLOSURE SHOWN ON A1.00ALTERNATE 4: PROVIDE CEILING UPGRADES IN LOBBY AREAS AS SHOWN IN RCPSALTERNATE 5: PROVIDE SOLID SURFACE COUNTER TOPS AT ALL LOCATIONS
BASE SCOPE PROVIDE PLAM AT COUNTERS AS INDICATED IN DRAWINGSALTERNATE 6: PROVIDE MINGLE TABLES & CHAIRS IDENTIFIED IN LANDSCAPE DRAWINGS
REFER TO SPECIFICAITON 012300 FOR FURTHER DEFINITION OF ALTERNATES / BASE SCOPE
NORTH
All information appearing herein shall not be duplicated, discharged orotherwise used without the written consent of Sink Combs Dethlefs
Issues/Revisions: Date:
SCD Project No.:
10/16/13SCHEMATIC DESIGN
02/07/14DESIGN DEVELOPMENT
04/04/1480% CD SET / PERMIT SET
05/02/14100% CD SET
WELCOME CENTER
A0.10
CODE ANALYSIS
COLORADO SCHOOL OF MINESGOLDEN, CO
1219
420 SF
MAINMECHANICAL
2880 SFSTORAGE 195 SF
MAIN ELECTRICAL
47 SFELEV
S-1 OCCUPANCY @ SHADED AREA4180 SF / 300 SF PER OCC14 OCCUPANTS
14DOOR
3" EXIT WIDTH REQUIRED33" PROVIDED
STAIR5" EXIT WIDTH REQUIRED
54" PROVIDED
90 FT TRAVEL DISTANCE < 100 FTMAX PER IBC TABLE 1021.2
SMOKE RESISTIVE ASSEMBLYPER IBC 509.4.1.
96 FT TRAVEL DISTANCE < 100 FTMAX PER IBC TABLE 1021.2
FEFE
FE
WATER ENTRY AREA,RE: PLUMBING
153 SFOFFICE
487 SFLARGE MEETING A
504 SFLARGE MEETING B
311 SFTOUR WAITING
88 SFSTORAGE
371 SF
HERITAGELOUNGE
108 SFOFFICE
100 SFOFFICE
128 SFBREAK
137 SFOFFICE
186 SF
CATERINGKITCHEN
53 SFCUSTODIAL
121 SFOFFICE
129 SFCONFERENCE
94 SFTELE
154 SFSTORAGE
170 SFOFFICE
107 SFOFFICE
107 SFOFFICE
167 SFOFFICE
66 SFELECT
108 SFCOPY/MAIL
264 SFWOMEN RR
186 SFMEN RR
111 SFOFFICE
107 SFOFFICE
382 SFCONFERENCE
108 SFOFFICE
42 SFSTORAGE
651 SFLOBBY
93 SFRECEPTION
1132
11
25
28
33
34
30
182
DOOR7" EXIT WIDTH REQUIRED33" PROVIDED
DOOR6" EXIT WIDTH REQUIRED33" PROVIDED
DOOR37" EXIT WIDTH REQUIRED
66" PROVIDED
DOOR32" EXIT WIDTH REQUIRED
66" PROVIDED
DOOR7" EXIT WIDTH REQUIRED
39" PROVIDED
LANDING - CONVERGING EXIT LOAD18" EXIT WIDTH REQUIRED
65" PROVIDED
B OCCUPANCY @ SHADED AREA6640 SF / 100 SF PER OCC67 OCCUPANTS
A-3 OCCUPANCY @ PUBLIC AREASEE PLAN FOR OCCUPANT LOAD
413 SF
TOURPRESENTATION
736 SFOPEN OFFICE
277 SFWAITING
632 SFOPEN OFFICE
47 SFELEV
187 SFSTAIR 1
441 SFLOBBY
88
184 SFSTAIR 2
FE FIRE EXTINGUISHERBELOW RECEPTIONDESK COUNTER
PROVIDE 1-HR RATEDFLOOR CONSTRUCTIONBELOW MECHANICALSHAFT EQ. TO UL D935
61
2015
DOOR4" EXIT WIDTH REQUIRED
33" PROVIDED
DOOR3" EXIT WIDTH REQUIRED
33" PROVIDED
SWINGING GATE AT LEVELOF EXIT DISCHARGE
160
33 35
171 SFOFFICE
121 SFOFFICE
127 SFWOMEN RR
130 SFBREAK ROOM
69 SFELECT
89 SFOFFICE
104 SFOFFICE
106 SFOFFICE116 SF
OFFICE
123 SFOFFICE
106 SFOFFICE
86 SFOFFICE
126 SFOFFICE
123 SFOFFICE
64 SFCUSTODIAL
118 SFOFFICE
210 SFMEETING
327 SFPHONE-A-THON
71 SFCOPY
102 SFUA STORAGE
171 SFFA STORAGE
100 SFIT STOR
96 SFTELE
95 SFCONFERENCE
108 SFOFFICE
52 SFMEN RR
101 SFOFFICE
41
DOOR9" EXIT WIDTH REQUIRED
33" PROVIDED
STAIR13" EXIT WIDTH REQUIRED
54" PROVIDED
40
DOOR8" EXIT WIDTH REQUIRED33" PROVIDED
STAIR12" EXIT WIDTH REQUIRED54" PROVIDED
B OCCUPANCY @ SHADED AREA8100 SF / 100 SF PER OCC81 OCCUPANTS
2368 SFOPEN OFFICE
418 SFHALL
331 SFHALL
187 SFSTAIR 1
47 SFELEV
98 SFOPEN OFFICE
184 SFSTAIR 2
REFER TO CODE ANALYSIS REPORT FOR GENERAL CODE INFORMATION.
THE CODE ANALYSIS PLANS INDICATE GENERAL LOCATIONS OF FIRERESISTIVE PARTITIONS AND SHAFTS.
ALL FIRE RESISTIVE CONSTRUCTION SHALL CONFORM TO THE APPLICABLEREQUIREMENTS OF THE REFERENCED FIRE RESISTIVE DESIGN ASSEMBLIES.
ALL HORIZONTAL AND/OR VERTICAL PENETRATIONS OF FIRE RESISTIVEASSEMBLIES SHALL BE FIRE STOPPED TO PROVIDE THE SAME LEVEL OF FIRERESISTANCE AS THE ASSEMBLY IN WHICH THEY OCCUR.
PROVIDE FIRE SAFING INSULATION BETWEEN EXTERIOR WALL FRAMING ANDFLOOR ASSEMBLIES TO PREVENT THE PASSAGE OF SMOKE AND FIRE AT THECONCEALED EXTERIOR WALL CAVITY.
1.
2.
3.
4.
5.
CODE ANALYSIS PLAN NOTES
SMOKE RESISTIVE ASSEMBLY PER IBC 508.2.5.2
CODE ANALYSIS PLAN LEGEND
2-HOUR RATED FIRE BARRIER
FE4A/60B/C FIRE EXTINGUISHER.
LOCATIONS TO BE VERIFIED PER THEINTERNATIONAL BUILDING, FIRE CODE & A.H.J.SEMI-RECESSED CABINETS TO PROTRUDE FROMWALL SURFACE NO MORE THAN 4" MAX.
1-HOUR RATED FIRE BARRIER
All information appearing herein shall not be duplicated, discharged orotherwise used without the written consent of Sink Combs Dethlefs
Issues/Revisions: Date:
SCD Project No.:
10/16/13SCHEMATIC DESIGN
02/07/14DESIGN DEVELOPMENT
04/04/1480% CD SET / PERMIT SET
05/02/14100% CD SET
WELCOME CENTER
A0.11
CODE ANALYSISPLANS
COLORADO SCHOOL OF MINESGOLDEN, CO
1219
3/32" = 1'-0"1
BASEMENT LEVEL CODE PLAN
3/32" = 1'-0"2
FIRST FLOOR LEVEL CODE PLAN
3/32" = 1'-0"3
SECOND FLOOR LEVEL CODE PLAN
140 SFWOMEN RR
136 SFTELE
94 SFCUSTODIAL
77 SFELECT
142 SFMEN RR
124 SFOFFICE
125 SFOFFICE
147 SFOFFICE
173 SFOFFICE
136 SFCONFERENCE
133 SFCONFERENCE
91 SFCOPY
85 SFBREAK
102 SFWORK RM
93 SFCOPY/STOR.
427 SFOPEN OFFICE
108 SFOFFICE
108 SFOFFICE
422 SFOPEN OFFICE
166 SFWORK RM/CONF
107 SFOFFICE
117
118
DOOR24" EXIT WIDTH REQUIRED33" PROVIDED
STAIR36" EXIT WIDTH REQUIRED54" PROVIDED
DOOR24" EXIT WIDTH REQUIRED
33" PROVIDED
STAIR36" EXIT WIDTH REQUIRED
54" PROVIDED
B OCCUPANCY @ SHADED AREA7315 SF / 100 SF PER OCC74 OCCUPANTS
1294 SFOPEN OFFICE
477 SFHALL
443 SFHALL
187 SFSTAIR 1
184 SFSTAIR 2
263 SFHALL
128 SFOFFICE
168 SFOFFICE
214 SFWAITING
BALCONY - 804 SF161 OCCUPANTS /5 SF PER OCC
80
81
145 SFCONFERENCE
NO MECHANICAL EQUIPMENT TO BELOCATED WITHIN 10'-0" OF ROOF EDGE
RT
U, R
E: M
EC
H
SCREEN WALLAROUND ROOF TOPMECHANICAL UNIT
36"x36" ROOF ACCESSHATCH
48"x48" ROOFACCESS HATCH
14' - 5"
23' -
9"
OPENING IN SCREEN WALLFOR ROOF ACCESS
EXHAUST FAN, RE: MECH
REFER TO CODE ANALYSIS REPORT FOR GENERAL CODE INFORMATION.
THE CODE ANALYSIS PLANS INDICATE GENERAL LOCATIONS OF FIRERESISTIVE PARTITIONS AND SHAFTS.
ALL FIRE RESISTIVE CONSTRUCTION SHALL CONFORM TO THE APPLICABLEREQUIREMENTS OF THE REFERENCED FIRE RESISTIVE DESIGN ASSEMBLIES.
ALL HORIZONTAL AND/OR VERTICAL PENETRATIONS OF FIRE RESISTIVEASSEMBLIES SHALL BE FIRE STOPPED TO PROVIDE THE SAME LEVEL OF FIRERESISTANCE AS THE ASSEMBLY IN WHICH THEY OCCUR.
PROVIDE FIRE SAFING INSULATION BETWEEN EXTERIOR WALL FRAMING ANDFLOOR ASSEMBLIES TO PREVENT THE PASSAGE OF SMOKE AND FIRE AT THECONCEALED EXTERIOR WALL CAVITY.
1.
2.
3.
4.
5.
CODE ANALYSIS PLAN NOTES
SMOKE RESISTIVE ASSEMBLY PER IBC 508.2.5.2
CODE ANALYSIS PLAN LEGEND
2-HOUR RATED FIRE BARRIER
FE4A/60B/C FIRE EXTINGUISHER.
LOCATIONS TO BE VERIFIED PER THEINTERNATIONAL BUILDING, FIRE CODE & A.H.J.SEMI-RECESSED CABINETS TO PROTRUDE FROMWALL SURFACE NO MORE THAN 4" MAX.
1-HOUR RATED FIRE BARRIER
All information appearing herein shall not be duplicated, discharged orotherwise used without the written consent of Sink Combs Dethlefs
Issues/Revisions: Date:
SCD Project No.:
10/16/13SCHEMATIC DESIGN
02/07/14DESIGN DEVELOPMENT
04/04/1480% CD SET / PERMIT SET
05/02/14100% CD SET
WELCOME CENTER
A0.12
CODE ANALYSISPLANS
COLORADO SCHOOL OF MINESGOLDEN, CO
1219
3/32" = 1'-0"1
THIRD FLOOR LEVEL CODE PLAN
3/32" = 1'-0"2
ROOF LEVEL CODE PLAN
PLANNORTH TRUE
NORTH