COBRADZR Brass

COBRAGenuine

COBRATeamAssist

Capillary Fittings

CONTENTS

Introduction

Capillary Fittings

Making a Capillary Joint

Capillary Fittings

Copper Tubing for Domestic Plumbing

Why Choose Cobra

1

2

3

4

19

21

INTRODUCTION

Capillary FittingsCapillary Fittings

Cobra introduced Capillary (or Solder) fittings to the South African market in 1972. These fittings were, at the time, imported and did not have much impact on the traditional compression fittings and copper tube market. However, with the introduction of hard drawn copper tubing, this system has gained in popularity, particularly in those areas wheregalvanised piping has been used traditionally. Hard drawn copper tubing, when used with Cobra “Copcal” fittings, is comparable in cost to conventional systems.

1

2

CAPILLARY FITTINGS

The simple joining technique is a readily acquired skill and can be mastered with little difficulty. Users of Cobra Capillary fittings find this plumbing method much faster than any other.

The introduction of a hard drawn copper tube is less expensive than the widely used domestic copper tube, making it the first choice for copper tube installation, a most economic proposition. The hard drawn copper tube when used with Cobra fittings, is comparable in cost with conventional systems.

The savings in installation time, the competitive price of hard drawn copper tube and Cobra Capillary fittings, as well as the undeniable longevity of copper, make the selection of this system sound economic sense.

NOTE: Fittings with a “D-” prefix are manufactured from Dezincification Resistant Brass.

3

MAKING A CAPILLARY JOINT

1. Copper tube can be cut with a hacksaw: a fine tooth blade is best, or use a roller tube cutter; Do not put too much pressure on the cutting disk.

2. Clean the ends of the tube with a file or de-burring tool, inside and outside.

3. Apply flux to the outside of tube and inside cup of fitting so that the surfaces to be joined are completely covered. Use flux carefully and sparingly.

4. Bend end of solder wire over- about the length of the size of the fitting ie. 15mm solder for 15mm fittings, etc. Over 50mm diameter, approximately three times the diameter of the fitting is required.

5. Apply flame to the fitting to heat the tube and the top of the fitting until soldermelts when placed at the joint, and then pass the flame towards the centre of the fitting until solder is absorbed and joint completed.

6. Remove excess solder with a small brush (or a damp cloth) while the fitting cools.

4

CAPILLARY FITTINGS

600M

601M*

Straight Slip Coupler.Copper to Copper connections.

Straight Slip Coupler.Copper to Copper connections.

*Component Code is differentiated by the inclusion of sizeie. 601M-15 = 15mm Straight Coupler

15mm, 22mm,28mm, 35mm,42mm, 54mm.

15mm, 22mm,28mm, 35mm,42mm, 54mm.

5

CAPILLARY FITTINGS

601M*

601M-TC

Reducing Straight Coupler.Copper to Copper connections.

Straight Tap Connector.Copper to Female Iron connections.

*Component Code is differentiated by the inclusion of sizeie. 601M-22x15 = 22mm x 15mm Reducing Straight Coupler

22mm x 15mm, 28mm x 22mm,35mm x 28mm, 42mm x 35mm,54mm x 42mm.

15mm x ½”; 15mm x ¾”;22mm x ¾”.

6

CAPILLARY FITTINGS

601-2M

Reducing Straight Coupler.Copper to Copper connections.

(To reduce a fitting).

22mm x 15mm; 28mm x 15mm;28mm x 22mm; 35mm x 15mm;35mm x 22mm; 35mm x 28mm;42mm x 15mm; 42mm x 22mm;42mm x 28mm; 42mm x 35mm;54mm x 15mm; 54mm x 22mm;54mm x 28mm; 54mm x 35mm;54mm x 42mm; 67mm x 35mm;67mm x 54mm; 76mm x 35mm;76mm x 54mm; 76mm x 67mm;

108mm x 76mm.

7

CAPILLARY FITTINGS

D603

D603M

Straight Female Coupler.Copper to Female Iron connections.

Reducing Straight Female Coupler.Copper to Female Iron connections.

15mm x ½”; 22mm x ¾”;28mm x 1”; 35mm x 1¼”;42mm x 1½”; 54mm x 2”;76mm x 3”; 108mm x 4”;

15mm x ¾”.

15mm x ¾”.

8

CAPILLARY FITTINGS

D604M

D604M-15X3/4

Reducing Straight Male Coupler.Copper to Male Iron connections.

Reducing Straight Male Coupler.Copper to Male Iron connections.

15mm x ½”; 22mm x ¾”;28mm x 1”; 35mm x 1¼”;42mm x 1½”; 54mm x 2”;76mm x 3”; 108mm x 4”.

15mm x ¾”.

9

CAPILLARY FITTINGS

606M

607M*

Elbow 45°.Copper to Copper connections.

Elbow 90°.Copper to Copper connections.

*Component Code is differentiated by the inclusion of sizeie. 607M-15 = 15mm Elbow 90°

15mm; 22mm;28mm; 35mm;42mm; 54mm;

76mm; 108mm.

15mm; 22mm;28mm; 35mm;42mm; 54mm;67mm; 76mm;

108mm.

10

CAPILLARY FITTINGS

607M*

607M-TC

Reducing Elbow 90°.Copper to Copper connections.

Bent Tap Connector.Copper to Female Iron connections.

22mm x 15mm.

15mm x ½”; 22mm x ¾”.

*Component Code is differentiated by the inclusion of sizeie. 607M-22x15 = 22mm x 15mm Reducing Elbow 90°

11

CAPILLARY FITTINGS

D707-3M

D707-3M

Reducing Female Elbow 90°.Copper to Female Iron connections.

Female Elbow 90°.Copper to Female Iron connections.

15mm x ½”; 22mm x ¾”.

28mm x 1”; 35mm x 1¼”;42mm x 1½”; 54mm x 2”.

12

CAPILLARY FITTINGS

D707-3-5M

D707-4M

Wallplate Elbow 90°.Copper to Female Iron connections.

Male Elbow 90°.Copper to Male Iron connections.

15mm x ½”; 22mm x ¾”.

15mm x ½”; 22mm x ¾”;28mm x 1”; 35mm x 1¼”;42mm x 1½”; 54mm x 2”.

13

CAPILLARY FITTINGS

611M*

611M

Reducing Tee.All ends Copper. Run equally reduced.

Equal Tee.All ends Copper.

15mm x 15mm x 22mm.

15mm; 22mm;28mm; 35mm;42mm; 54mm;67mm; 76mm;

108mm.

*Component Code is differentiated by the inclusion of sizeie. 611M-15x15x22 = 15mm x 15mm x 22mm Reducing Tee

14

CAPILLARY FITTINGS

611M*

Reducing Tee.All ends Copper. Branch reduced.

22mm x 22mm x 15mm; 28mm x 28mm x 15mm;28mm x 28mm x 22mm; 35mm x 35mm x 15mm;35mm x 35mm x 22mm; 35mm x 35mm x 28mm;42mm x 42mm x 15mm; 42mm x 42mm x 22mm;42mm x 42mm x 28mm; 42mm x 42mm x 35mm;54mm x 54mm x 22mm; 54mm x 54mm x 28mm;54mm x 54mm x 35mm; 54mm x 54mm x 42mm;67mm x 67mm x 54mm; 76mm x 76mm x 35mm;76mm x 76mm x 42mm; 76mm x 76mm x 54mm;

108mm x 108mm x 54mm;108mm x 108mm x 76mm.

*Component Code is differentiated by the inclusion of sizeie. 611M-22x22x15 = 22mm x 22mm x 15mm Reducing Tee

15

CAPILLARY FITTINGS

611M*

611M*

Reducing Tee.All ends Copper.

One end on Run reduced.

Reducing Tee.All ends Copper.

Run and Branch equally reduced.

22mm x 15mm x 22mm;28mm x 22mm x 28mm.

22mm x 15mm x 15mm;28mm x 22mm x 22mm.

*Component Code is differentiated by the inclusion of sizeie. 611M-22x15x22 = 22mm x 15mm x 22mm Reducing Tee

*Component Code is differentiated by the inclusion of sizeie. 611M-22x15x15 = 22mm x 15mm x 15mm Reducing Tee

16

CAPILLARY FITTINGS

D712M

617M

Reducing Tee.Copper to Copper to

Female Iron connections.

Tube End Cap.

15mm x ½”; 22mm x ¾”.

15mm; 22mm;28mm; 35mm;42mm; 54mm.

17

CAPILLARY FITTINGS

D733M

733-3M

Union Coupler.Copper to Copper connections.

Union Coupler.Copper to Female Iron connections.

15mm; 22mm.

15mm x ½”.

18

CAPILLARY FITTINGS

D733-4M

636M

Union Coupler.Copper to Male Iron connections.

Full Crossover.Copper to Copper connections.

15mm x ½”; 22mm x ¾”.

15mm; 22mm.

19

COPPER TUBING FOR DOMESTIC PLUMBING

Tubes for Domestic Plumbing Services

Class 2 (Medium)

Class 1 (Light)

15 15,045 14,955 1,0 0,392 7,54

22 22,055 21,945 1,0 5,000,588

28 28,055 27,945 1,2 4,720,900

35 35,070 34,930 1,5 1,407 4,72

42 42,070 41,930 1,5 1,701 3,81

54 54,070 53,930 2,0 4,062,912

76 76,170 76,030 2,0 2,854,150

108 108,070 107,930 2,5 7,385 2,50

Maximum WorkingPressure Mpa

Class 2Half Hard

TheoreticalMass kg/m

Class 2

WallThickness

Class 2 Med.(mm)

Min(mm)

Max(mm)

NominalSize ofTube(mm)

Outside Diameter

Class 1 (Light)

Maximum WorkingPressure Mpa

Class 1Half Hard

TheoreticalMass kg/m

Class 1

WallThickness

Class 1 Med.(mm)

Min(mm)

Max(mm)

NominalSize ofTube(mm)

Outside Diameter

15 15,045 14,955 0,280 5,16

22 22,055 21,945 0,532 4,50

28 28,055 27,945 0,683 3,50

35 35,070 34,930 1,136 3,74

42 42,070 41,930 1,371 3,03

54 54,070 53,930 1,774 2,40

76 76,170 76,030 3,133 2,12

108 108,070 107,930

0,70

0,90

0,90

1,20

1,20

1,20

1,50

1,50 4,473 1,49

15 15,045 14,955 1,0 0,392 7,54

22 22,055 21,945 1,0 5,000,588

28 28,055 27,945 1,2 4,720,900

35 35,070 34,930 1,5 1,407 4,72

42 42,070 41,930 1,5 1,701 3,81

54 54,070 53,930 2,0 4,062,912

76 76,170 76,030 2,0 2,854,150

108 108,070 107,930 2,5 7,385 2,50

Maximum WorkingPressure Mpa

Class 2Half Hard

TheoreticalMass kg/m

Class 2

WallThickness

Class 2 Med.(mm)

Min(mm)

Max(mm)

NominalSize ofTube(mm)

Outside Diameter

Class 1 (Light)

Maximum WorkingPressure Mpa

Class 1Half Hard

TheoreticalMass kg/m

Class 1

WallThickness

Class 1 Med.(mm)

Min(mm)

Max(mm)

NominalSize ofTube(mm)

Outside Diameter

15 15,045 14,955 0,280 5,16

22 22,055 21,945 0,532 4,50

28 28,055 27,945 0,683 3,50

35 35,070 34,930 1,136 3,74

42 42,070 41,930 1,371 3,03

54 54,070 53,930 1,774 2,40

76 76,170 76,030 3,133 2,12

108 108,070 107,930

0,70

0,90

0,90

1,20

1,20

1,20

1,50

1,50 4,473 1,49

20

Maximum Working

Class 0

Pressure MpaClass 0

Half Hard

TheoreticalMass kg/m

Class 0

WallThickness

Class 0 Med.(mm)

Min(mm)

Max(mm)

NominalSize ofTube(mm)

Outside Diameter

15 15,045 14,955 0,60 0,242 4,93

22 22,055 21,945 0,75 0,447 4,18

28 28,055 27,945 0,80 0,610 3,59

35 35,070 34,930 1,20 1,137 4,20

42 42,070 41,930 1,20 1,372 3,48

54 54,070 53,930 1,20 1,775 2,69

76 76,170 76,030 1,50 3,133 2,38

108 108,070 107,930 1,50 4,473 1,67

COPPER TUBING FOR DOMESTIC PLUMBING

Class 0 (Light)

21

WHY CHOOSE COBRA...

Superior thread engagement and number of turns.No Squeak – torque up with confidence.Supported by award winning Cobra Assist nationwide service team.4 decades of proven track-record.

NOTES

NOTES

20 Wright Street, Factoria,Krugersdorp, 1739South Africa

National After Sales Service Number: +27 (0) 861 21 21 21

ONLINE PLATFORMSVisit our websites and find an office/dealer/distributor closest to you.

Websites: https://cobra.lixil.co.za/http://www.lixil.co.za/

Social Media:

- @Cobrataps

- @CobraWatertechSA