cold water storage tank - Minera Roof Trusses · 2019-11-28 · Minera Roof Trusses Limited Five...

Post on 07-Apr-2020

52 views 0 download

transcript

Minera Roof Trusses LimitedFive Crosses Industrial Estate, Minera, Wrexham LL11 3RD

Email: quotes@minera-rooftrusses.com • Telephone: (01978) 758869

www.minera-rooftrusses.com

Cold Water Storage Tank Platform Detail

DETAIL ‘A’

DETAIL ‘B’

Water storage tank support detail in accordance with BS 5268 Part III for maximum span of truss 9.000m. Maximum tank size 300 litres supported on 4 trussed rafters (as Detailed A) OR 230 litres supported on 3 trussed rafters (as Detail B).

MAXIMUM SPAN 9,000m.

ALTERNATIVE SUPPORT BETWEEN MEMBERSWhere space is limited this detail may be used between members A & B and B & C in order to gain head room. However, a minimum clearance of 25mm above the ceiling lining should be allowed, for possible deflection.

Drawing Number: MRT-SD-10Designer: BS5268Last Revised: July 2016

Connect with us:

Company Registration Number: 1325682

Tankplacedcentral

Span of truss

S = Truss Spacing

Galvanised steeljoist hanger

B

1⁄3 point

1⁄3 pointC Bearer ‘A’ placed as

close to 1⁄3 point as possible

1⁄3 point

Wallplate Wallplate

Tank

TankCC

C

C

BB

BA

SS

S

S

S

S

S

S

S

A

S

S

B

A

1⁄2

1⁄2

1⁄2

1⁄2

1⁄3

2⁄3

2⁄3

1⁄3