COMPONENT
ENTITYNOTES APPLY
TO ALL ENTITIESFURNISH INSTALL
COMMON WORK
CONDUIT SLEEVES EC EC 1
PENETRATION GC GC 5,7
HANGER SUPPORTS FOR CONDUITS EC EC 1
HANGER SUPPORTS FOR CABLE SUPPORTS TC TC 2
WIDE BASE CABLE SUPPORTS (J-HOOKS) TC TC 2
STRAPS/SLINGS TC TC 2
ELECTRICAL FOR COMMUNICATIONS SYSTEMS
CONDUIT, FITTINGS, PULL STRINGS EC EC 1
JUNCTION BOXES EC EC 1
DEVICE BOXES EC EC 1
PULL BOXES EC EC 1
TABLE-TOP INTERFACE (ROUGH IN) AVC AVC 4
TABLE-TOP INTERFACE (DEVICE) AVC AVC
TELECOMMUNICATIONS (COMMUNICATIONS CABLING SYSTEM) TC TC
AUDIOVISUAL SYSTEM(S)
LOUDSPEAKERS AVC AVC
HANGER WIRE SUPPORTS FOR LOUDSPEAKERS WITHIN LAYING CEILINGS AVC AVC
MICROPHONES AVC AVC
EQUIPMENT RACKS AVC AVC
ANTENNA AVC AVC
PROJECTION SCREEN AVC AVC
INTERFACE PLATES AVC AVC
PROJECTORS AVC AVC
CAMERAS AVC AVC
PODIUM AVC AVC
VOLUME CONTROL AVC AVC
CONTROL PANEL AVC AVC
SCREEN SWITCH AVC AVC
STRUCTURAL SUPPORTS FOR AV EQUIPMENT GC GC 9
GENERAL NOTES
A. COMPONENTS, ENTITY, AND FURNISH AND INSTALL RESPONSIBILITIES INDICATED ARE RECOMMENDATIONS ONLY AND PROVIDED ASA COURTESY TO CONTRACTOR.
B. SOME COMPONENTS AND ASSOCIATED FURNISH AND INSTALL RESPONSIBILITIES MAY NOT BE INDICATED ON THIS MATRIX.
C. THE DETAIL FURNISH / INSTALL CALLOUT ANNOTATION PROVIDES SPECIFIC RECOMMENDATIONS THAT SUPERSEDE GENERALRECOMMENDATIONS FOUND IN THE TECHNOLOGY RESPONSIBILITY MATRIX.
D. EQUIPMENT SCHEDULES MAY CONTAIN ADDITIONAL FURNISH OR INSTALL RESPONSIBILITY RECOMMENDATIONS. THESE SUPERSEDERECOMMENDATIONS FOUND IN DETAIL ANNOTATIONS AND THE TECHNOLOGY RESPONSIBILITY MATRIX.
E. CONTRACTOR IS RESPONSIBLE FOR FINAL DETERMINATION OF ALL COMPONENTS AND ASSOCIATED FURNISH AND INSTALLRESPONSIBILITIES REQUIRED FOR PROVISION OF COMPLETE TECHNOLOGY SYSTEMS READY FOR OWNER'S USE. DETERMINATIONOF SUCH SHALL OCCUR PRIOR TO BID.
F. DETERMINATION AND EXECUTION OF ALL NECESSARY COMPONENTS AND ASSOCIATED FURNISH AND INSTALL RESPONSIBILITIESSHALL CONFORM TO PROJECT SCHEDULE.
G. CABLING FOR COMPONENTS SHALL BE PROVIDED BY ENTITY INSTALLING COMPONENT UNLESS OTHERWISE INDICATED.
H. EACH TRADE SHALL COORDINATE ROUGH-IN REQUIREMENTS (INCLUDING SLEEVES) WITH ELECTRICAL CONTRACTOR PRIOR TOROUGH-IN.
I. DEVICES AND HORIZONTAL CABLING OF DEVICES (INCLUDING CABLE TERMINATIONS) WITHIN ASSEMBLIES (FLOOR BOXES,POKE-THROUGHS, TABLE TOP INTERFACES, WALL BOXES, FURNITURE FEEDS, UTILITY POLES, SURFACE RACEWAYS, ETC.) SHALL BEBY RESPECTIVE TRADES.
MATRIX NOTES
1. EACH RESPECTIVE TRADE SHALL COORDINATE EXTENT OF WORK WITH ELECTRICAL CONTRACTOR PRIOR TO ROUGH IN.
2. EACH TRADE SHALL COORDINATE PROVISION OF THIS COMPONENT WITH TELECOMMUNICATIONS CONTRACTOR.TELECOMMUNICATIONS CONTRACTOR SHALL PROVIDE THIS COMPONENT UNLESS DETERMINED OTHERWISE IN CONJUNCTION WITHTELECOMMUNICATIONS CONTRACTOR.
4. FURNISHING CONTRACTOR TO PROVIDE ROUGH IN DIMENSIONS / TEMPLATE AND DESIRED LOCATION FOR TABLE TOP INTERFACE.INSTALLING CONTRACTOR SHALL CUT-OUT SURFACE OF TABLE, IDENTIFYING AND COORDINATING ANY POTENTIAL CONFLICTS WITHDESIRED LOCATION PRIOR TO PERFORMING ANY WORK.
5. EACH TRADE SHALL COORDINATE PROVISION OF THIS COMPONENT WITH GENERAL CONTRACTOR. GENERAL CONTRACTOR SHALLPROVIDE THIS COMPONENT UNLESS DETERMINED OTHERWISE IN CONJUNCTION WITH GENERAL CONTRACTOR.
7. ELECTRICAL CONTRACTOR SHALL COORDINATE EXTENT OF WORK WITH GENERAL CONTRACTOR.
9. AUDIOVISUAL CONTRACTOR SHALL COORDINATE EXTENT OF WORK WITH GENERAL CONTRACTOR.
TITLESHEET#
SHEET LISTSHEET LIST
*
KEYNOTE
DRAWING NOTE
EQUIPMENT SCHEDULE ID
REVISION NUMBER
SECTION OR ELEVATION CALLOUT
DESCRIPTIONSYMBOL
OR (XX###)
#REFERENCE INDICATORREFERENCE SHEET NUMBER
ENLARGED FLOOR PLAN, SCHEDULE, OR DETAIL CALLOUT
*#
REFERENCE INDICATORREFERENCE SHEET NUMBER
ROOM WALL ELEVATION CALLOUT
A,B,C,D#
WALL ELEVATION REFERENCEREFERENCE SHEET NUMBER
BREAK LINE
DETAIL FURNISH / INSTALL CALLOUT (ON DETAILS WHERE CALLOUTSARE USED, ASSUME EC FOR X AND Y WHERE NOT INDICATED FORCOMPONENTS) UON IN TECHNOLOGY RESPONSIBILITY MATRIX)
X INDICATES ENTITY (ABBREVIATED) RIMROCK RECOMMENDS BE RESPONSIBLE FOR FURNISHING
Y INDICATES ENTITY (ABBREVIATED) RIMROCK RECOMMENDS BE RESPONSIBLE FOR INSTALLING
X Y
CONTINUANCE LINE
TELECOM AREA BOUNDARY LINE
TELECOM ROOM BOUNDARY LINE
XY
TYPICAL WALL MOUNTED DEVICE NOTATION. EXAMPLE:
CEILING-MOUNTED SPEAKER
WALL-MOUNTED SPEAKER
TYPICAL STATION CALLOUT
X INDICATES NUMBER OF VOICE/DATA PORTS/CABLES
Y INDICATES NUMBER OF COAX PORTS/CABLES (ASSUME 0 IF BLANK)
TYPICAL POLE OR BOOM MOUNTED DEVICE NOTATION. EXAMPLE:
WALL-MOUNTED SECURITY CAMERA
POLE-MOUNTED SECURITY CAMERA
+H
TYPICAL DEVICE OR EQUIPMENT NON-STANDARD HEIGHT(TELECOM OUTLET EXAMPLE SHOWN)
H INDICATES DIMENSION OF DEVICE OR EQUIPMENT CENTERLINE (UON) ABOVE FINISHED FLOOR
IF
TYPICAL ASSEMBLY NOTATION, INCLUDES:
- INFRASTRUCTURE: FLOOR BOX, POKE-THRU, WALL BOX, SURFACE RACEWAY, ENCLOSURE, HOUSING, RACK, ETC.
- SERVICES: DEVICES AND/OR CABLING AS SHOWN ASSOCIATED WITH INFRASTRUCTURE.
(FLOORBOX WITH INTERFACE PLATE AND TELECOM OUTLET EXAMPLE SHOWN).
2
A
X
WALL
SYMBOL/DEVICE CONGESTION NOTATION INCLUDES:
LEADER INDICATOR: USED TO IDENTIFY INTENDED LOCATION OF SYMBOL(S) THAT WOULD OTHERWISE OVERLAP OR CREATE CONGESTION WITH OTHER SYMBOLOGY.
TARGET INDICATOR: USED TO IDENTIFY INTENDED LOCATION OF LEADER ARROWHEAD TERMINATION THAT WOULD OTHERWISE OVERLAP OR CREATE CONGESTION WITH OTHER SYMBOLOGY.
CONGESTION INDICATOR: USED TO IDENTIFY ARRANGEMENT OF CONGESTED DEVICES.
X INDICATES CONGESTION TYPE: H HORIZONTAL V VERTICAL (ALONG SAME STUD OR STUD CAVITY) B BOTH HORIZONTAL AND VERTICAL -- SINGLE ITEM (NOT ALIGNED)
2
A
X
FUTURE EQUIPMENT, RACK, OR ENCLOSURE OUTLINE
#
XX##
XX###
#
OR #
*
#
A
B
C
D #
* #
DRAWING ANNOTATIONS
S
A
A
S
SYMBOL
SYMBOL
DESCRIPTIONDESCRIPTIONSYMBOL SYMBOL
STRUCTURAL BLOCKOUT
CABLE PATHWAY FIRESTOPPING DEVICE
FIRE-RATED FLOOR PENETRATION ASSEMBLY
CABLE SUPPORT PATHWAY(J-HOOKS / STRAPS / SLINGS)
GROUNDING BUSBAR
GROUND
WxH
CS
CONDUIT UNDERGROUND / FLOOR / SLAB
CONDUIT WITH BUSHING
CONDUIT WITH CAP
CONDUIT DOWN
CONDUIT / CABLE HOME RUN
PULL BOXP
DEVICE BOX EMPTY (CEILING)
FLOOR BOX
POKE THRU
U UTILITY POLE
ENCLOSURE
WALL BOX
CABLE TRAY
SURFACE RACEWAYSR
MAINTENANCE HOLE
OSP UNDERGROUND DUCTBANKOSP
DEVICE BOX EMPTY
CT
DESCRIPTIONSYMBOL
CABLE RUNWAY
CABLE - END LOOP
CABLE - CONTINUOUS LOOP
TELECOM OUTLET
TELECOM OUTLET (CEILING)
CR
AUDIOVISUAL EQUIPMENT LOCATION
A LOUDSPEAKER
FIXED CAMERA
VIDEO DISPLAY
PROJECTION SCREEN
INTERFACE PLATE
PROJECTOR
A
A
IF
LECTERN
PAN - TILT - ZOOM CAMERA
A AUDIOVISUAL DEVICE
AUDIOVISUAL CEILING DEVICE
AUDIOVISUAL FIELD LOCATED DEVICE
A
A
NOT ALL ITEMS LISTED IN THIS LEGEND ARE USED ON TECHNOLOGY DRAWINGS.
SUBSCRIPTS ADJACENT SYMBOLS ELSEWHERE ON DRAWINGS INDICATE ADDITIONAL INFORMATION REGARDING APPLICATIONOF DEVICE OR EQUIPMENT. REFER TO ABBREVIATIONS, DRAWING ANNOTATIONS, SCHEDULES, AND SPECIFICATIONS FORADDITIONAL SYMBOL SUBSCRIPT INFORMATION.
MULTIPLE SUBSCRIPTS ADJACENT A SYMBOL SIGNIFY MULTIPLE DEVICE TYPES OR MULTIPLE INSTALLATION REQUIREMENTSFOR ONE OR MORE DEVICES. MULTIPLE SUBSCRIPTS REPRESENTING DIFFERENT DEVICE TYPES ADJACENT A SYMBOL ISEQUIVALENT TO MULTIPLE DEVICES LOCATED AT THE SAME OR APPROXIMATE PLAN LOCATION, BUT AT DIFFERENTELEVATIONS. THE FIRST SUBSCRIPTS (STARTING FROM THE LEFT OR TOP) IS ASSOCIATED WITH THE DEVICE AT THE HIGHESTELEVATION, THE SECOND SUBSCRIPT IS ASSOCIATED WITH THE DEVICE AT THE NEXT HIGHEST ELEVATION, ETC.
1.
2.
3.
CONTROL PANELCP
EA
FSD
FPA
COMMUNICATIONS EQUIPMENT LOCATIONET
CONDUIT UP
LEGEND
LEGEND NOTES
COMMUNICATIONS
AUDIOVISUAL COMMON WORK / ELECTRICAL
T COMMUNICATIONS DEVICE
COMMUNICATIONS CEILING DEVICE
COMMUNICATIONS FIELD LOCATED DEVICE
T
T
EQUIPMENT RACK
E
ABBREV. DEFINITIONABBREV. DEFINITION
ABBREVIATIONSTECHNOLOGY RESPONSIBILITY MATRIX
© Copyright BCER Engineering Inc.
Copyright reserved. All parts of this drawing are the exclusive
property of BCER Engineering and shall not be used or
reproduced in any manner without express written consent.
Client:
Project #:
Designed By:
Drawn By:
Approved By:
Scale:
No DateDescription
ISSUE RECORD
100% CONSTRUCTION DOCUMENTS
10/23/2015
NONE
TECHNOLOGY TITLESHEET
UCCS
CO
LO
MB
INE
HA
LL A
UD
IOV
I SU
AL U
PG
RA
DE
S
RIMROCK
RIMROCK
81515004
UN
IV
ER
SIT
Y O
F C
OL
OR
AD
O C
OLO
RA
DO
SP
RIN
GS
RIMROCK
T0.00
AU
ST
IN B
LU
FF
S P
KW
Y, C
OLO
RA
DO
SP
RIN
GS
, C
O 8
091
8
T0.00 TECHNOLOGY TITLE SHEET
T0.01 TECHNOLOGY PROJECT NOTES
T0.02 TECHNOLOGY SCHEDULES
T2.01 TECHNOLOGY PLAN - LEVEL 03
T4.01 TECHNOLOGY SPACE PLANS
T4.02 TECHNOLOGY SPACE PLANS
T5.01 TECHNOLOGY DETAILS
T5.02 TECHNOLOGY DETAILS
ML MONITORED LATCH
MM MULTIMODE FIBER OPTIC CABLE
MREX MOTION REQUEST TO EXIT
MS MONITORED STRIKE
(N) NEW
(NL) NEW LOCATION
NA NOT APPLICABLE
NACLGS NON ACCESSIBLE CEILING SPACE
NC NORMALLY CLOSED CONTACT
NEC NATIONAL ELECTRIC CODE
NO NORMALLY OPEN CONTACT
NS NETWORK SWITCH
NTS NOT TO SCALE
NVR NETWORK VIDEO RECORDER
O OWNER
OB OVERRIDE BUTTON
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
OHM RESISTIVE NETWORK
OPE OWNER PROVIDED EQUIPMENT
OR OPERATING ROOM
ORI OPERATING ROOM INTEGRATION
OSP OUTSIDE PLANT
OXY OXYGEN
PA PUBLIC ADDRESS
PDS PROTECTIVE DISTRIBUTION SYSTEM
POE POWER OVER ETHERNET
PP PATCH PANEL(S)
PR PAIR
PRJ PROJECTOR
PS POWER SUPPLY
PWR POWER
(RL) REMOVE AND RELOCATE
(RE) REMOVE
R RISER
REV REVISION
REX REQUEST TO EXIT SWITCH
RF RADIO FREQUENCY
RFG RAISED FLOOR GROMMET
RI READER INTERFACE
RM ROOM
RMC RIGID METALLIC CONDUIT
RNC RIGID NONMETALLIC CONDUIT
RS-232 TWO WAY SERIAL DATA STREAM
S STATION
SATV SATELLITE TELEVISION
SC SECURITY CONTRACTOR
SCC SECURITY CAMERA
SCHED SCHEDULE
SCNS SECURITY CAMERA NETWORK SWITCH
SCP SECURITY CONTROL PANEL
SCPP SECURITY CAMERA PATCH PANEL
SCPS SECURITY CAMERA POWER SUPPLY
SH SURFACE HOUSING
SM SINGLEMODE FIBER OPTIC CABLE
SMR SURFACE METAL RACEWAY
SMT SURFACE MOUNT
SN SERIAL NETWORK MODULE
SP SURGE PROTECTOR
SPEC SPECIFICATION
SPKR LOUDSPEAKER LEVEL AUDIO
SPR SURFACE PLASTIC RACEWAY
SR SURFACE RACEWAY
SRR SERVER ROOM
STP SHIELDED TWISTED PAIR
SUS SUSPENDED
SV S-VIDEO
TB TERMINATION BLOCK(S)
TBB TELECOMMUNICATIONS BONDING BACKBONE
TBD TO BE DETERMINED
TC TELECOMMUNICATIONS CONTRACTOR
TCP TEMPERATURE CONTROL PANEL
TEL TELEPHONE
TGB TELECOMMUNICATIONS GROUNDING BUSBAR
TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
TP TWISTED PAIR
TR TELECOMMUNICATIONS ROOM (IDF, FD)
TYP TYPICAL
U UNIT
UGND UNDERGROUND
UON UNLESS OTHERWISE NOTED
UPP UNSHIELDED TWISTED PAIR PATCH PANEL
UPS UNINTERRUPTIBLE POWER SUPPLY
USB UNIVERSAL SERIAL BUS
UTP UNSHIELDED TWISTED PAIR
VB VOICE BACKBONE
VE VOICE
VGA HD ANALOG VIDEO TYP 15 PIN D-SUB
VGA+A HD ANALOG VIDEO TYP 15 PIN D-SUB & 3.5MM TRS
VGCB VOICE-GRADE COPPER BACKBONE
VLAN VIRTUAL LOCAL AREA NETWORK
VMS VIDEO MANAGEMENT STATION
VOIP VOICE OVER INTERNET PROTOCOL
VSS VIDEO SURVEILLANCE SYSTEM
VTC VIDEO TELE-CONFERENCING
VW VIDEO WALL
W WALL TELEPHONE
WM WALL MOUNTED
WP WEATHER PROOF
WAP WIRELESS ACCESS POINT
AC ABOVE COUNTER
ACEG ALTERNATING CURRENT ELECTRICAL GROUND
ACLGS ACCESSIBLE CEILING SPACE
ACP ACCESS CONTROL PANEL
ACS ACCESS CONTROL SYSTEM
ACT ACOUSTIC CEILING TILE
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AO AUTOMATIC OPERATOR
AOC AUTOMATIC OPENER CONTROLLER
APC ANGLE POLISHED CONNECTOR
APP AUDIO PATCH PANEL
APPROX APPROXIMATELY
AR AUXILIARY RELAY
ARCH ARCHITECT
ATEL ADMINISTRATIVE TELEPHONE
AV AUDIOVISUAL
AVC AUDIOVISUAL CONTRACTOR
AWG AMERICAN WIRE GAUGE
BAS BUILDING AUTOMATION SYSTEM
BB BACKBONE
BC BARE COPPER
BEP BUILDING ENTRANCE PROTECTOR
BI BIOMETRIC INTERFACE
BLDG BUILDING
BO BY OTHERS
C CONDUIT
CAB CABINET
CAN CONTROLLED AREA NETWORK
CAT3 CATEGORY 3 COPPER CABLE
CAT5E CATEGORY 5E COPPER CABLE
CAT6 CATEGORY 6 COPPER CABLE
CAT6A CATEGORY 6 AUGMENTED COPPER CABLE
CATV CABLE TELEVISION
CC CONTACT CLOSURE
CCTV CLOSED CIRCUIT TELEVISION
CER CYLINDER ELECTRIC RETRACTION
CLG CEILING
CNL COULD NOT LOCATE
CO CONDUIT ONLY (NO CABLE)
COAX COAX CABLE
COM COMMON
COMM COMMUNICATION
CON CONDUCTOR
CPU COMPUTER PROCESSING UNIT
CPV COMPONENT VIDEO
CR CARD READER
CT COUNT
CV COMPOSITE VIDEO
DB DIRECT BURIAL
(D) DEMOLISH
DD DEAD
DEA DELAYED EGRESS ALARM
DGCB DATA-GRADE COPPER BACKBONE
DIA DIAMETER
DM DIGITAL MULTIMEDIA (SIGNAL)
DP DISPLAYPORT
DPDT DOUBLE POLE DOUBLE THROW
DPS DOOR POSITION SWITCH
DS DIGITAL SIGNAGE
DVI DIGITAL VIDEO INTERFACE
DVR DIGITAL VIDEO RECORDER
DWG DRAWING
(E) EXISTING TO REMAIN
EB EXIT BUTTON
EC ELECTRICAL CONTRACTOR
ECL ELECTRIC CYLINDER LOCK
ECP ELEVATOR CONTROL PANEL
EF ENTRANCE FACILITY (DEMARC)
EIB EMERGENCY INFORMATION BOARD
EL ELECTRIC LATCH
ELEC ELECTRICAL
ELM ELECTRIC LATCH WITH LATCH MONITOR SWITCH
ELR ELECTRICAL LATCH RETRACTION
ELV ELEVATOR
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EQPMT EQUIPMENT
ER EQUIPMENT ROOM
ES ELECTRIC STRIKE
ESO ELECTRICAL SOLENOID
EXIST EXISTING
(F) FUTURE
FAC FIRE ALARM CONTRACTOR
FACP FIRE ALARM CONTROL PANEL
FB FIBER BACKBONE, FLOOR BOX
FD FLOOR DISTRIBUTOR
FL FLUSH
FLEX FLEXIBLE CONDUIT
FPA FLOOR PENETRATION ASSEMBLY
FPD FLAT PANEL DISPLAY
FS FURNITURE SUPPLIER
FSD FIRE STOP DEVICE
G GROUND
GC GENERAL CONTRACTOR
HB HANDICAP BUTTON
HC HORIZONTAL CABLE
HD HIGH DEFINITION
HDBT HDBASET (AV SIGNALS OVER TP)
HDMI HIGH DEFINITION MULTIMEDIA INTERFACE
HO HOLD OPEN
ID INSIDE DIAMETER OR IDENTIFIER
IDS INTRUSION DETECTION SYSTEM
IF INTERFACE PLATE
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
IP INTERNET PROTOCOL
IR INFRARED
ISP INSIDE PLANT
IVW IN VARIANCE WITH
IWC IN-BUILDING WIRELESS CONTRACTOR
KIT KITCHEN EQUIPMENT
LAB LABORATORY EQUIPMENT
LC LOW VOLTAGE/SPECIALITY CONTRACTOR
LL LINE LEVEL LEFT CHANNEL AUDIO
LM LINE LEVEL MONO AUDIO
LPS LOCK POWER SUPPLY
LR LINE LEVEL RIGHT CHANNEL AUDIO
MAG MAGNETIC LOCK
MECH MECHANICAL
MED MEDICAL EQUIPMENT
MFR MANUFACTURER
MIC MICROPHONE (CONNECTION)
MIN MINIMUM
RIMROCK CONTACTS
Arvada Office5420 Ward Road, Suite 200Arvada, CO 80002Phone: 303.422.7400
Colorado Springs Office10807 New Allegiance Drive, Suite 400Colorado Springs, CO, CO 80921Phone: 719.533.1112
PROJECT MANAGER
Andy Burkart719.886.2459andy.burkart@rimrockgroup.com
CONSTRUCTION ADMINISTRATOR
Andy Burkart719.886.2459andy.burkart@rimrockgroup.com
A PROJECT NOTES INDICATE GENERAL REQUIREMENTS FOR WORK INDICATED ON THEDRAWINGS. APPLICABLE PROJECT NOTES SHALL BE CONSIDERED PART OF GENERAL NOTESFOR EACH SHEET.
B REVIEW ALL NOTES FOR ALL TRADES TO ASSURE FULL COORDINATION BETWEEN ALL TRADES.
C SPEAKER LOCATIONS SHOWN ARE APPROXIMATE. COORDINATE SPEAKER LOCATIONS WITHOTHER CEILING DEVICES. ENSURE THAT FINAL SPEAKER LOCATIONS MEET THE SOUNDREINFORCEMENT INTENT FOR THE TARGET AREA.
A PROJECT NOTES INDICATE GENERAL REQUIREMENTS FOR WORK INDICATED ON THEDRAWINGS. APPLICABLE PROJECT NOTES SHALL BE CONSIDERED PART OF GENERAL NOTESFOR EACH SHEET.
B EVERY CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE GENERAL NOTES - GENERALSECTION FOR PROJECT NOTES THAT APPLY TO MORE THAN ONE TRADE AS WELL AS ALLOTHER NOTES PROVIDED FOR OTHER TRADES FOR FULL COORDINATION BETWEEN ALLTRADES.
A PROJECT NOTES INDICATE GENERAL REQUIREMENTS FOR WORK INDICATED ON THEDRAWINGS. APPLICABLE PROJECT NOTES SHALL BE CONSIDERED PART OF GENERAL NOTESFOR EACH SHEET.
B UNLESS OTHERWISE NOTED IN THE PROJECT NOTES, THE GENERAL REQUIREMENTS OF THEPROJECT NOTES SHALL GOVERN WORK INDICATED ON THE DRAWINGS, UNLESS SPECIFICNOTATION ELSEWHERE ON THE DRAWINGS INDICATES DIFFERENT REQUIREMENTS, IN WHICHCASE THE DIFFERENT REQUIREMENTS INDICATED ELSEWHERE SHALL GOVERN.
C EXAMINE THE CONTRACT DOCUMENTS IN THEIR ENTIRETY, INCLUDING BUT NOT LIMITED TOGENERAL AND SUPPLEMENTAL REQUIREMENTS, DRAWINGS AND SPECIFICATIONS OF OTHERDIVISIONS, AND ADDENDA, FOR EQUIPMENT OR WORK WHICH MAY AFFECT WORK UNDER THISSECTION, REGARDLESS OF WHETHER SUCH REQUIREMENTS OR WORK ARE SPECIFICALLYINDICATED IN THIS SECTION.
D WORK SHALL COMPLY WITH THE GOVERNING REQUIREMENTS LISTED IN THE SPECIFICATIONS.
E IF DISCREPANCIES OR CONFLICTS ARE DISCOVERED IN THE CONSTRUCTION DOCUMENTS, THECONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING AND WAIT FOR INSTRUCTION PRIOR TOPROCEEDING WITH WORK RELATED TO DISCREPANCIES OR CONFLICTS.
F SUBSTITUTIONS OF PRODUCT AND DEVIATIONS FROM METHODS OF CONSTRUCTION SPECIFIEDSHALL BE CONSIDERED AT SUBMITTAL REVIEW. SUCH SUBSTITUTIONS USED FOR BID SHALL BEAT THE SOLE RISK OF CONTRACTOR, AND AS SUCH ARE SUBJECT TO REJECTION WITHOUTCONSIDERATION.
G RECORD DRAWINGS SHALL BE MAINTAINED ON SITE PER SPECIFICATIONS SHOWINGADDITIONS, CHANGES, DELETIONS THROUGHOUT CONSTRUCTION.
H PROVIDE SEISMIC BRACING AS REQUIRED BY THE GOVERNING REQUIREMENTS.
I DRAWING ELEMENTS SHOWN IN GRAY ARE TO BE INSTALLED AS PART OF A DIFFERENT BIDPACKAGE OR PROVIDED BY OTHERS. WHERE SUCH ELEMENTS AFFECT THE CONTRACTORSWORK, COORDINATE DEPENDENCIES WITH APPLICABLE OTHERS IN A TIMELY MANNER, BEFORESUCH DEPENDENCIES ARISE IN THE FIELD.
J THIS PROJECT SHALL BE ACTIVELY MANAGED BY THE CONTRACTOR'S PROJECT MANAGERWHICH SHALL NOT ALSO BE THE CONTRACTOR'S FOREMAN OR BE INVOLVED IN TECHNICALWORK IN THE FIELD. DOWNTIME, DELAYS OR NON-SCHEDULED OUTAGES DUE TO THECONTRACTOR'S FAILURE TO ACTIVELY MANAGE THE WORK, INCLUDING BUT NOT LIMITED TOEFFECTIVELY PLANNING, SEQUENCING, SCHEDULING, AND EXECUTING THE WORK WILL NOT BEACCEPTABLE AT ANY TIME.
K WORK REQUIRING UTILITY AND/OR TECHNOLOGY SYSTEM OUTAGES SHALL BE COORDINATEDWITH THE OWNER IN ADVANCE AND PRE-APPROVED IN WRITING.
L COORDINATION IS REQUIRED PRIOR TO ROUGH-IN. DRAWINGS ARE DIAGRAMMATIC AND SHALLNOT BE SCALED FOR BOX, DEVICE AND/OR EQUIPMENT LOCATIONS. LOCATIONS INDICATEDARE APPROXIMATE AND DO NOT REPRESENT THE ACTUAL FIELD CONDITION OR FINALLOCATION. FURTHERMORE, REQUIREMENTS FOR ROUGH-IN BOXES, EQUIPMENT DIMENSIONS,MOUNTING/HEIGHTS, SUPPORTS, FACEPLATES, CONDUIT ROUTING, AND/OR INTERFACES MAYVARY. COORDINATE FINAL LOCATIONS AND REQUIREMENTS WITH ACTUAL FIELD CONDITIONS,SHOP DRAWINGS, RESPECTIVE TRADE(S), ARCHITECT, AND/OR OWNER PRIOR TO ROUGH-IN.
M WHERE COORDINATION DICTATES THAT FINAL LOCATIONS VARY SIGNIFICANTLY FROM THATSHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND AWAITAPPROVAL PRIOR TO ELECTRICAL ROUGH-IN.
N IDENTIFY AND COORDINATE WITH OTHER TRADES LOCATION AND SIZE OF REQUIRED OPENINGSIN NEW CONCRETE OR MASONRY PRIOR TO THE FORMING AND POURING OF CONCRETE ORCONSTRUCTION OF MASONRY. OPENINGS MAY NOT BE INDICATED ON DRAWINGS.
O CONTRACTOR SHALL COORDINATE ALL PENETRATIONS, OPENINGS, FASTENERS,CONNECTIONS, HANGERS, AND SUPPORTS WITH STRUCTURAL DRAWINGS AND ENGINEERPRIOR TO COMMENCEMENT OF WORK. WHEN LOCATING AND SIZING ALL PENETRATIONSTHROUGH THE STRUCTURAL SLABS REFER TO THE STRUCTURAL DETAILS DEPICTINGALLOWABLE LOCATIONS AND OPENINGS. THE CONTRACTOR SHALL PREPARE A DRAWING(S) OFALL PENETRATIONS AND COORDINATE THIS DRAWING(S) WITH THE GENERAL CONTRACTORAND ALL OTHER TRADES TO VERIFY THAT THE LOCATIONS OF TECHNOLOGY REQUIREDPENETRATIONS DO NOT CONFLICT WITH PENETRATIONS REQUIRED BY ALL OTHER TRADES.
P PENETRATION OF CONCRETE AND STRUCTURAL ELEMENTS SHALL BE AVOIDED WHEREPOSSIBLE. OBTAIN WRITTEN APPROVAL FROM STRUCTURAL ENGINEER/ARCHITECT PRIOR TOSUCH NECESSARY PENETRATIONS.
Q PROVIDE SLEEVES FOR LOCATIONS WHERE CABLE PASSES THROUGH WALLS, FLOORS, ORFOUNDATIONS. SLEEVES SHALL BE SIZED TO SUPPORT CABLES PER NEC FILL RATIOS ANDTIA/EIA 569 CABLE CAPACITY STANDARDS PLUS <25 PERCENT> FUTURE EXPANSION.
R PROVIDE CABLE PATHWAY FIRESTOPPING DEVICES FOR LOCATIONS WHERE CABLE WILLPENETRATE FIRE RATED BARRIERS. REFER TO ARCHITECTURAL DRAWINGS FOR WALL TYPEINFORMATION. PROVIDE CABLE PATHWAY FIRESTOPPING DEVICE(S) IN SUFFICIENT QUANTITYSUCH THAT THE COMBINED USEABLE CROSS SECTIONAL AREA OF THE DEVICE(S) MATCHES OREXCEEDS THE CROSS SECTIONAL AREA OF CABLE TRAY TO BE SERVED.
S FOR EACH CABLE PATHWAY FIRESTOPPING LOCATION SHOWN FEEDING CABLE TRAY, PROVIDECABLE PATHWAY FIRESTOP DEVICE(S) IN SUFFICIENT QUANTITY SUCH THAT THE COMBINEDUSEABLE CROSS-SECTIONAL AREA OF THE DEVICE(S) IS GREATER THAN OR EQUAL TO THECROSS-SECTIONAL AREA OF CABLE TRAY TO BE SERVED. FOR ALL OTHER FIRESTOPLOCATIONS, PROVIDE CABLE PATHWAY FIRESTOP DEVICE(S) IN SUFFICIENT QUANTITY SUCHTHAT THE COMBINED USEABLE CROSS-SECTIONAL AREA OF THE DEVICE(S) IS GREATER THANTHE CROSS-SECTIONAL AREA OF ALL CABLES TO PASS THROUGH THE DEVICES, PLUS THEADDITIONAL AMOUNT (PERCENTAGE) REQUIRED BY THE SPECIFICATIONS OR ELSEWHERE FORFUTURE EXPANSION.
T PER NEC REQUIREMENTS, TECHNOLOGY ITEMS SHALL NOT BE SECURED TO OR SUPPORTED BYSUSPENDED CEILING SYSTEM (INCLUDING SUPPORTS WIRES), HANGERS FOR CABLESUPPORTS SHALL BE INDEPENDENT (DEDICATED). PER NEC REQUIREMENTS, WIRE HANGERSSHALL BE SUPPORTED AT BOTH ENDS AND DISTINGUISHABLE FROM SUSPENDED CEILINGSYSTEM SUPPORT WIRE. IN EXPOSED STRUCTURAL CEILING SPACES, WIRE SHALL NOT BEUSED AS A HANGER FOR SUPPORT.
U HANGERS AND SUPPORTS SHALL BE PROVIDED AT INTERVALS PER THE NEC, SHALL BEATTACHED TO STRUCTURE AND NOT BE ATTACHED TO OTHER BUILDING SYSTEMS AND THEIRASSOCIATED SUPPORTS. CABLE SUPPORTS SHALL BE MOUNTED AT VARYING INTERVALS NOTTO EXCEED 5 FEET AND ROUTED PARALLEL AND PERPENDICULAR TO BUILDING LINES. CABLESUPPORTS SHALL NOT SHARE CABLES OF DIFFERENT TECHNOLOGY SYSTEMS OR EXCEED 50PERCENT OF THE MANUFACTURER'S RECOMMENDED FILL. INCLUDE CABLE SUPPORT ROUTINGON RECORD DRAWINGS.
V CABLE DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR WITHIN 4HOURS OF THE DAMAGING EVENT, AT NO ADDITIONAL COST TO THE OWNER.
W COORDINATE WITH AUDIOVISUAL EQUIPMENT SUPPLIER AND SHOP DRAWINGS TO FINALIZE ALLSTRUCTURAL SUPPORT REQUIREMENTS AND LOCATIONS FOR DISPLAYS, PROJECTORS ANDPROJECTION SCREENS PRIOR TO ROUGH-IN.
X SPEAKER LOCATIONS SHOWN ARE APPROXIMATE. COORDINATE SPEAKER LOCATIONS WITHOTHER CEILING DEVICES. ENSURE THAT FINAL SPEAKER LOCATIONS MEET THE SOUNDREINFORCEMENT INTENT FOR THE TARGET AREA.
GENERAL NOTES
COMMON WORK / ELECTRICAL
AUDIOVISUALGENERAL
© Copyright BCER Engineering Inc.
Copyright reserved. All parts of this drawing are the exclusive
property of BCER Engineering and shall not be used or
reproduced in any manner without express written consent.
Client:
Project #:
Designed By:
Drawn By:
Approved By:
Scale:
No DateDescription
ISSUE RECORD
100% CONSTRUCTION DOCUMENTS
10/23/2015
NONE
TECHNOLOGY PROJECTNOTES
UCCS
CO
LO
MB
INE
HA
LL A
UD
IOV
I SU
AL U
PG
RA
DE
S
RIMROCK
RIMROCK
81515004
UN
IV
ER
SIT
Y O
F C
OL
OR
AD
O C
OLO
RA
DO
SP
RIN
GS
RIMROCK
T0.01
AU
ST
IN B
LU
FF
S P
KW
Y, C
OLO
RA
DO
SP
RIN
GS
, C
O 8
091
8
A ACCESSIBLE: EASY ACCESS. ACCESS ATTAINED WITHOUT REQUIRING EXTENSIVE REMOVALOF OTHER MATERIALS TO GAIN ACCESS.
B ACCESSIBLE CEILING: ACOUSTICAL TILE HANGING CEILINGS (“HARD-LID” CEILINGS (CONCEALEDSPINE OR SHEETROCK/GYPSUM CEILINGS), EVEN WHEN PROVIDED WITH ACCESS PANELS, ARENOT CONSIDERED AN ACCESSIBLE CEILING.)
C BY OTHERS: A PARTY OR ENTITY OTHER THAN THE CONTRACTOR. THE CONTRACTOR SHALLENGAGE THE GENERAL CONTRACTOR, ARCHITECT, AND/OR OWNER TO DETERMINE THIS PARTYOR ENTITY FOR CONSIDERATION OF PRICING AND/OR EXECUTION OF THE WORK.
D COMMUNICATIONS (OR TECHNOLOGY) GROUNDING SYSTEM: INCLUDES (BUT IS NOT LIMITEDTO) PROVIDING A PERMANENT GROUNDING AND BONDING INFRASTRUCTURE FOR THECOMMUNICATIONS CABLING SYSTEM.
E ELECTRICAL FOR COMMUNICATIONS SYSTEMS ALSO REFERED TO AS COMMUNICATIONS (ORTECHNOLOGY) PATHWAY SYSTEM: INCLUDES (BUT IS NOT LIMITED TO) DEVICE BOXES, PULLBOXES, CONDUIT, CABLE TRAY, DUCT/DUCTBANK, AND OTHER PATHWAY AND RACEWAYCOMPONENTS NECESSARY TO PROVIDE PATHWAY FOR, SUPPORT, AND ROUTECOMMUNICATIONS CABLES.
F CONCEALED: HIDDEN FROM SIGHT IN INTERSTITIAL BUILDING SPACES, CHASES, FURREDSPACES, SHAFTS, CRAWL SPACES, ETC.
G CONSTRUCTION DOCUMENTS: COLLECTIVE TERM FOR THE ENTIRE SET OF BOUND ORUNBOUND MATERIAL DESCRIBING THE CONSTRUCTION AND SERVICES REQUIRED, INCLUDINGALL DRAWINGS, SPECIFICATIONS, ADDENDA ISSUED PRIOR TO EXECUTION OF THE CONTRACT,AND MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT (SUCH AS CHANGEORDERS, CONSTRUCTION CHANGE DIRECTIVES, SUPPLEMENTAL INSTRUCTIONS, ETC.).
H CONTRACT DOCUMENTS: THE AGREEMENT (INCLUDING OTHER DOCUMENTS LISTED IN THEAGREEMENT), CONDITIONS OF THE CONTRACT (GENERAL, SUPPLEMENTARY AND OTHERCONDITIONS), AND THE CONSTRUCTION DOCUMENTS.
I EXPOSED: NOT CONCEALED AND NOT INSTALLED UNDERGROUND.
J FURNISH: TO PURCHASE, SUPPLY, AND DELIVER TO THE PROJECT MATERIALS IN NEW ANDOPERABLE CONDITION, READY FOR INSTALLATION.
K GOVERNING AUTHORITY: ENTITIES OR THEIR REPRESENTATIVES CHARGED WITH FORMATIONAND/OR ENFORCEMENT OF GOVERNING REQUIREMENTS, SUCH AS THE AUTHORITY HAVINGJURISDICTION (AJH).
L INSTALL: TO PLACE IN FINAL POSITION IN FULLY OPERABLE, TESTED CONDITION.
M PROVIDE: TO FURNISH AND INSTALL, COMPLETE, TESTED AND READY FOR INTENDED USE.
N ROUGH-IN: PROVIDE THE COMMUNICATIONS PATHWAY SYSTEM, INCLUDING (BUT NOT LIMITEDTO) DEVICE BOXES, PULL BOXES, WALL BOXES, FLOOR BOXES, POKE-THROUGH DEVICES,CONDUIT, ENCLOSURES, CABLE TRAY, DUCTS/DUCTBANKS, MAINTENANCE HOLES, HANDHOLES, AND OTHER PATHWAYS AND ITEMS INDICATED (OR AS REQUIRED) FOR ROUTING,SUPPORTING, AND INSTALLING COMMUNICATIONS CABLES, DEVICES, OR EQUIPMENT WHICHSHALL BE PROVIDED BY OTHERS OR PROVIDED UNDER A SUBSEQUENT SET OF CONTRACTDOCUMENTS.
PROJECT PHASING SCHEDULE
PHASE DATES ROOMS NOTES
1 12/21/15 THRU 1/8/16 317
2 3/21/16 THRU 3/27/16 322, 325 SCD 3/23/16 4PM
3 5/16/16 THRU 6/12/16 323, 324, 333
3A 5/16/16 THRU 5/21/16 334 SCD 5/18/16 4PM
3B 6/6/16 THRU 6/11/16 329 SCD 6/8/16 4PM
NOTES:
1) CONFIRM ALL DATES WITH UCCS PROJECT MANAGEMENT.
2) SIGNIFICANT COMPLETION DATE (SCD) SHALL BE 5 BUSINESS DAYS PRIOR TO END OF GIVENPROJECT PHASE UNLESS OTHERWISE NOTED.
SYMBOL
SYMBOL
SYMBOL
CR-X
ET
WxH
SR
U
CS
OSP
CT-DxW
FSD
FPA
A
A
IF
A
A
A
CP
EA
T
T
T
DEVICE SCHEDULE
A
A
A
AUDIOVISUAL COMMON WORK / ELECTRICAL
COMMUNICATIONS
P
SUBSCRIPT DESCRIPTION DETAILS ID
E
SHEETDETAIL
DETAIL INDEXTERMS AND DEFINITIONS
GENERAL
PHASING SCHEDULE
© Copyright BCER Engineering Inc.
Copyright reserved. All parts of this drawing are the exclusive
property of BCER Engineering and shall not be used or
reproduced in any manner without express written consent.
Client:
Project #:
Designed By:
Drawn By:
Approved By:
Scale:
No DateDescription
ISSUE RECORD
100% CONSTRUCTION DOCUMENTS
10/23/2015
NONE
TECHNOLOGYSCHEDULES
UCCS
CO
LO
MB
INE
HA
LL A
UD
IOV
I SU
AL U
PG
RA
DE
S
RIMROCK
RIMROCK
81515004
UN
IV
ER
SIT
Y O
F C
OL
OR
AD
O C
OLO
RA
DO
SP
RIN
GS
RIMROCK
T0.02
AU
ST
IN B
LU
FF
S P
KW
Y, C
OLO
RA
DO
SP
RIN
GS
, C
O 8
091
8
CABLE SUPPORT PATHWAY
(NO SUBSCRIPT) TE-CR JS001
J J-HOOKS JS010
CABLE TRAY (DEPTH x WIDTH)
(NO SUBSCRIPT) TE-BJ, TE-CT,TE-CTUB,
TE-CR
CT201
GROUNDING BUSBAR
TGB GROUND BUS GB020
TMBG MAIN GROUND BUS GB010
DEVICE BOX EMPTY
(NO SUBSCRIPT) TE-CR
AV AUDIOVISUAL TE-CR,TA-DETAILS
FF FURNITURE FEED TE-CR
S SECURITY TS-SD
SEP SITE EMERGENCY PHONE TE-CR
DEVICE BOX EMPTY (CEILING)
(NO SUBSCRIPT) TA-IFB
AV AUDIOVISUAL TE-CR,TA-DETAILS
S SECURITY TS-SD
FLOOR BOX
(NO SUBSCRIPT) TE-FB CB001
FB4 4-GANG TE-FB CB004
FB6 6-GANG TE-FB CB006
FB8 8-GANG TE-FB CB008
FB10 10-GANG TE-FB CB010
FBF FURNITURE FEED TE-FB CB015
POKE THRU
PT6 6-INCH CB023
PT8 8-INCH CB025
PTF FURNITURE FEED
ENCLOSURE
AUDIOVISUAL CEILING BOX TA-PE
S SECURITY CEILING ENCLOSURE TS-SD
WALL BOX
VIDEO DISPLAY TA-DWB
EQUIPMENT RACK
AUDIOVISUAL (FLOOR) TA-IFER
W AUDIOVISUAL (WALL) TA-IFWR
HAND HOLE
(NO SUBSCRIPT)
MAINTENANCE HOLE
(NO SUBSCRIPT) TE-MH,TE-MHCE
MH100
SUBSCRIPT DESCRIPTION DETAILS ID
AUDIOVISUAL EQUIPMENT LOCATION
SHARED RACK SPACE (TYP TR) TC SERIES
LOUDSPEAKER
STANDARD (WALL) TA-IFWB
A TYPE A
B TYPE B
C TYPE C
LOUDSPEAKER (CEILING)
STANDARD ACT (REPLACEMENTOR CUT-IN)
N NON-ACCESSIBLE CEILING TA-CSD
P PENDANT TA-CSD
S SUB-WOOFER
VIDEO DISPLAY
STANDARD (WALL)
DS DIGITAL SIGNAGE
VIDEO DISPLAY (CEILING)
PLENUM ACT CEILING TA-PMD
A ACT CEILING TA-PMD
DS DIGITAL SIGNAGE
E EXPOSED TA-PMD
N NON-ACCESSIBLE CEILING TA-PMD
PROJECTION SCREEN
STANDARD (WALL) TA-WMS
PROJECTION SCREEN (CEILING)
RECESSED TA-CRS
C SUSPENDED TA-CSS
CONTROL PANEL
STANDARD (BACKBOX) TA-IFCP
A TYPE A TA-IFCP
T TABLE TOP / TOUCH PANEL
INTERFACE PLATE
STANDARD (WALL) TA-IFW
B TYPE B
C TYPE C
F STANDARD, FLOOR TA-FIF
T TABLE TOP / FURNITURE TA-TIF
PROJECTOR
SHORT THROW (INTERACTIVE) TA-WPD
A SHORT THROW (PRESENTATION)
B TYPE B
PROJECTOR (CEILING)
PLENUM ACT CEILING TA-PMD
A ACT CEILING TA-PMD
E EXPOSED TA-PMD
N NON-ACCESSIBLE CEILING TA-PMD
PROJECTOR LIFT
CEILING MOUNTED TA-PL
FIXED CAMERA (CEILING)
(NO SUBSCRIPT)
A TYPE A
PAN - TILT - ZOOM CAMERA
(NO SUBSCRIPT) TA-IFB
A TYPE A TA-IFB
PAN - TILT - ZOOM CAMERA (CEILING)
(NO SUBSCRIPT)
A TYPE A
LECTERN
(NO SUBSCRIPT)
AUDIOVISUAL DEVICE
ALS ASSISTIVE LISTENING
AP WIRELESS ACCESS POINTTRANSCEIVER
S SCREEN SWITCH
VC VOLUME CONTROL
WM WIRELESS MIC ANTENNA
AUDIOVISUAL CEILING DEVICE
ALS ASSISTIVE LISTENING
AP WIRELESS ACCESS POINTTRANSCEIVER
M MICROPHONE
WM WIRELESS MIC ANTENNA
AUDIOVISUAL FIELD LOCATED DEVICE
DM DUAL-ELEMENT BOUNDARYMICROPHONE
M MICROPHONE
TM TRI-ELEMENT BOUNDARYMICROPHONE
WC WEB CAM
SUBSCRIPT DESCRIPTION DETAILS ID
COMMUNICATIONS EQUIPMENT LOCATION
(NO SUBSCRIPT)
CABLE RUNWAY (X INDICATES MINIMUM WIDTH IN INCHES)
(NO SUBSCRIPT) TC-CR,TC-CRAD
ER200
A ALTERNATE SPACING TC-CR,TC-CRAD
ER201
CABLE - END LOOP
(NO SUBSCRIPT)
CABLE - CONTINUOUS LOOP
(NO SUBSCRIPT)
TELECOM OUTLET
(NO SUBSCRIPT) TE-CR
AC ABOVE COUNTER TE-CR
AV AUDIOVISUAL TE-CR,TA-DETAILS
DS DIGITAL SIGNAGE TE-CR,TA-DETAILS
E EMERGENCY INFORMATIONBOARD
TE-CR
ELEC ELECTRICAL EQUIPMENT TE-CR
ELV ELEVATOR EQUIPMENT TE-CR
EP EMERGENCY BLUE PHONE TE-CR
F FURNITURE MOUNTED
FACP FIRE ALARM CONTROL PANEL TE-CR
K KIOSK TE-CR
LCP LIGHTING CONTROL PANEL TE-CR
MECH MECHANICAL/HVAC EQUIPMENT TE-CR
POS POINT OF SALE TE-CR
S SECURITY CAMERA TS-CD
SR SURFACE RACEWAY
VND VENDING MACHINE TE-CR
W WALL TELEPHONE TE-CR
WAP WIRELESS ACCESS POINT TE-CR
TELECOM OUTLET (CEILING)
(NO SUBSCRIPT) TE-CR
AV AUDIOVISUAL TE-CR,TA-DETAILS
DS DIGITAL SIGNAGE TE-CR,TA-DETAILS
E EMERGENCY INFORMATIONBOARD
TE-CR
S SECURITY CAMERA TS-CD
WAP WIRELESS ACCESS POINT TE-CR
COMMUNICATIONS DEVICE
(NO SUBSCRIPT)
COMMUNICATIONS CEILING DEVICE
(NO SUBSCRIPT)
COMMUNICATIONS FIELD LOCATED DEVICE
(NO SUBSCRIPT)
TA-CRS - CEILING RECESSED SCREEN DETAIL T5.01
TA-CSD - CEILING SPEAKER DETAILS T5.01
TA-IFB - BACK BOX DETAIL FOR AV WALL INTERFACE REQUIRING BACKING T5.01
TA-IFER - BACK BOX DETAIL FOR AV EQUIPMENT RACK T5.01
TA-IFW - BACK BOX DETAIL FOR AV WALL INTERFACE T5.01
TA-PMD - PROJECTOR MOUNT DETAILS T5.02
TA-TTIF - TABLE TOP INTERFACE DETAIL T5.01
TA-VCW - BACK BOX DETAIL FOR AV DEVICE CONTROL T5.01
STRUCTURAL BLOCKOUT (WIDTH x HEIGHT)
CABLE PATHWAY FIRESTOPPING DEVICE TE-WFS FS102
FIRE-RATED FLOOR PENETRATION ASSEMBLY TE-FFS FS110
GROUND
CONDUIT WITH BUSHING
CONDUIT WITH CAP
CONDUIT UP
CONDUIT DOWN
CONDUIT / CABLE HOME RUN
SURFACE RACEWAY SR100
CONDUIT UNDERGROUND / FLOOR / SLAB
OSP UNDERGROUND DUCTBANK
PULL BOX MH400
UTILITY POLE
326326
312B
325
327
324
330
329
322 323
321
320
317
328 331
333
334
318
335
310
308
304A
316B316A
316
337
315
312C
312A
305 301
307
304
302300A
303
312E
312
312D 312F
314
312G 312H
313
320
337
338
DN
UP
DN
DN
UP
T-4.01
T-4.02
T-4.01
T-4.01 T-4.01
T-4.01 T-4.01
T-4.01
A ABANDON ALL EXISTING COPPER AND FIBER AUDIOVISUAL CABLING. PROVIDE STAINLESSSTEEL BLANK COVER FOR OUTLET BOX AT LECTERN. REMOVE CABLING FROM EXISTINGPROJECTOR POLE MOUNT AND AMX TELEVISION MANAGER AND LEAVE NEATLY COILED ATPROJECTOR LOCATION ABOVE CEILING. REMOVE AND RETURN AUDIO AMPLIFIER (LOCATEDNEAR PROJECTOR ABOVE CEILING), CEILING SPEAKERS, AMX TELEVISION MANAGER,PROJECTOR, AND SCREEN TO OWNER. REUSE EXISTING PROJECTOR POLE AND PROJECTORMOUNTING HARDWARE. REMOVE AND DISPOSE OF PODIUM.
T4.01
1
T4.02
1
T4.01
1
T4.01
1T4.01
1
T4.01
1
T4.01
1
T4.01
1
TE04 TE04TE04 TE04
TE04
TE04
TE04
DEMOLITION NOTES
© Copyright BCER Engineering Inc.
Copyright reserved. All parts of this drawing are the exclusive
property of BCER Engineering and shall not be used or
reproduced in any manner without express written consent.
Client:
Project #:
Designed By:
Drawn By:
Approved By:
Scale:
No DateDescription
ISSUE RECORD
100% CONSTRUCTION DOCUMENTS
10/23/2015
As indicated
TECHNOLOGY PLAN -LEVEL 03
UCCS
CO
LO
MB
INE
HA
LL A
UD
IOV
I SU
AL U
PG
RA
DE
S
RIMROCK
RIMROCK
81515004
UN
IV
ER
SIT
Y O
F C
OL
OR
AD
O C
OLO
RA
DO
SP
RIN
GS
RIMROCK
T2.01
AU
ST
IN B
LU
FF
S P
KW
Y, C
OLO
RA
DO
SP
RIN
GS
, C
O 8
091
8
N
0 8'8' 4'
T2.01
1/8" = 1'-0"
1 TECHNOLOGY PLAN - LEVEL 03
KEYNOTES
TE04 PROVIDE OUTLET BOXES FOR AUDIOVISUAL, TELECOMMUNICATIONS, ANDELECTRICAL SERVICES TO LECTERN AT THIS LOCATION. REFER TO DETAIL TA-IFERFOR RECOMMENDED LAYOUT AND ASSUMED TELECOMMUNICATION AND ELECTRICALREQUIREMENTS TO BE CONFIRMED BY OWNER. REFER TO RISER DIAGRAM ONTECHNOLOGY SPACE PLAN FOR ADDITIONAL INFORMATION AND REQUIREMENTS FORAUDIOVISUAL OUTLET BOXES.
IF
A
IF
A
TYPE DESCRIPTION MANUFACTURER PART NUMBER SPECIAL RQMTS
2 CHANNEL AUDIO AMPLIFIER CROWN DCi 2 | 300
WALL SURFACE LOUDSPEAKER MARTIN CDD5x MOUNTING BRACKET AS REQ.
DOCUMENT CAMERA WOLFVISION VZ-3
DIGITALMEDIA PRESENTATION SYSTEM CRESTRON DMPS3-4k-150-C
HDMI DA & EXTRACTOR CRESTRON HD-DA-2
A PROJECTOR EPSON G6470WU
APPLE TV APPLE APPLE TV
16:10 ELECTRIC RECESSED SCREEN DA-LITE 60" x 96" TENSIONED ADVANTAGE 113" DIAGONAL
S SCREEN SWITCH DA-LITE AS REQUIRED
TOUCHPANEL 7" CRESTRON TSW-752
TABLE STAND KIT FOR TSW-750 CRESTRON TSW-750-TTK-X-S
POE SWITCH 5 PORT CRESTRON CEN-SW-POE-5
SMART LECTERN ATF MT-400-UCCS-MAPLE-NATURAL-7302
POWER CONDITIONER FURMAN P-8 PRO II AS REQUIRED
INTERFACE PLATE CUSTOM RCI CUSTOM As Required
SPEAKON NEUTRIK As Required
ETHERCON CAT6A SHIELDED NEUTRIK As Required For Digital Media
Net Connect Cable XG620 4pr 23 AWG CMP Yellow Jacket AMP 4-1499416-7 For Digital Media
DISPLAY POLE MOUNTING HARDWARE CHIEF AS REQUIRED REUSE EXISTING
PROJECTOR MOUNT CHIEF RPAU (5) REUSE EXISTING, (2) NEW
ASSISTEDLISTENING
SYSTEM(OFOI)
COMPUTER(OFCI)
SMARTLECTURN
CABLE POCKET
DETAILAV-D1
TO NETWORKBY OTHERS
TO NETWORKBY OTHERS
TO NETWORKBY OTHERS
TO NETWORKBY OTHERS
TO NETWORKBY OTHERS
TO NETWORKBY OTHERS
8 OHM
HDMI
MIC
VGA
LL LR
CV
LL LR
HDBT
HDMI
HDMI
CC
USB
CC CC
LM
IP
POE
IP
IP
IP
IP
LM
HDMI
LM
HDMIIP
SPKR
SMART LECTERN
MT-400-UCCS-MAPLE-NATURAL -7302
DIGITALMEDIA
PRESENTATION
SYSTEM
*
DMPS3-4k-150-C
TOUCHPANEL 7"
*
TSW-752
TABLE STAND KIT
FOR TSW-750
TSW-750-TTK-X-S
DOCUMENT
CAMERA
*
VZ-3
POE SWITCH 5
PORT
CEN-SW-POE-5
16:10 ELECTRIC
RECESSED
SCREEN
*
60" x 96"
TENSIONED
ADVANTAGE 113"
DIAGONAL
PROJECTOR
*
G6470WU
SCREEN SWITCH
*
AS REQUIRED
HDMI DA &
EXTRACTOR
*
HD-DA-2
INTERFACE
PLATE
CUSTOM
As Required
HDBT
APPLE TV
*
APPLE TV
AUDIO AMPLIFIER
*
DCi 2 | 300
WALL SURFACE
LOUDSPEAKER
*
CDD5x
A REVIEW ALL CONTRACT DOCUMENTS FOR PROJECT REQUIREMENTS. TECHNOLOGY SPACEPLANS MAY NOT BE PROVIDED FOR ALL SYSTEMS AND ARE NOT EXHAUSTIVE. INFORMATIONPROVIDED IS PROGRAMMATIC; SOME ANCILLARY EQUIPMENT MAY BE SHOWN HEREIN FORCLARITY, BUT NOT ALL ANCILLARY EQUIPMENT IS SPECIFIED. PROVIDE ALL COMPONENTSNECESSARY FOR A FULLY FUNCTIONAL SYSTEM(S) READY FOR THE OWNERS USE.REQUIREMENTS FOR POWER, MOUNTING, CABLE MANAGEMENT, COOLING, AND OTHERMISCELLANEOUS COMPONENTS REQUIRED FOR A FULLY FUNCTIONING SYSTEM ARE ASSUMEDAND SHALL BE PROVIDED BY THE CONTRACTOR.
T4.01
2
S
TE03
A
B
6
1 W
2
TE05
TA02
FLOOR
CEILING
IF
(2) 1 1/4-INCH CONDUITS
A.
B.
C.
ALL MEASUREMENTS ARE TO CENTER UNLESS OTHERWISE NOTED.
STUB ALL CONDUITS TO ACCESSIBLE CEILING SPACE OF SAME ROOMUNLESS OTHERWISE ILLUSTRATED/NOTED IN RISER DIAGRAM.
ADDITIONAL CONDUITS FOR TELECOMM OR POWER MAY BE REQUIRED.REFERENCE DEVICE DETAILS AND TELECOMM AND ELECTRICAL PLANS.
RISER GENERAL NOTES
+18"
(2) 1-INCH CONDUITS
A S
+48"
+90"
(2) 1-INCH CONDUITS
IF+18"
(2) 1 1/4-INCH CONDUITS
(REF. DETAIL TA-IFER)
1
1. REFERENCE DETAIL TA-IFER FOR GENERAL LAYOUT INFORMATION ANDASSUMED ELECTRICAL AND TELECOMM REQUIREMENTS TO BE CONFIRMEDBY OWNER. LOCATE OUTLET BOXES SERVING LECTERN LOCATION PERKEYNOTE ON TECHNOLOGY FLOOR PLANS. PROVIDE A BLANK PLATE FORONE OF THE BOXES TO BE LEFT AS SPARE FOR FUTURE USE.
RISER DRAWING NOTES
EQUIPMENT SCHEDULE
GENERAL NOTES
© Copyright BCER Engineering Inc.
Copyright reserved. All parts of this drawing are the exclusive
property of BCER Engineering and shall not be used or
reproduced in any manner without express written consent.
Client:
Project #:
Designed By:
Drawn By:
Approved By:
Scale:
No DateDescription
ISSUE RECORD
100% CONSTRUCTION DOCUMENTS
10/23/2015
As indicated
TECHNOLOGY SPACEPLANS
UCCS
CO
LO
MB
INE
HA
LL A
UD
IOV
I SU
AL U
PG
RA
DE
S
RIMROCK
RIMROCK
81515004
UN
IVE
RS
ITY
OF C
OL
OR
AD
O C
OLO
RA
DO
SP
RIN
GS
RIMROCK
T4.01
AU
ST
IN B
LU
FF
S P
KW
Y, C
OLO
RA
DO
SP
RIN
GS
, C
O 8
091
8
N
0 4'4' 2'
T4.01
1/4" = 1'-0"
1 CLASSROOM ENLARGED FLOOR PLAN
0 4'4' 2'
T4.01
1/4" = 1'-0"
2 CLASSROOM PRESENTATION WALL ELEVATION
T4.01
3 CLASSROOM RISER DIAGRAM
T4.01
5 CLASSROOM AUDIOVISUAL ONE-LINE DIAGRAM
KEYNOTES
TA02 CENTER PROJECTOR SCREEN AND SPEAKER ON EXISTING PROJECTOR MOUNTLOCATION. AS ROOM LAYOUTS VARY, LOCATIONS SHALL BE REVIEWED ANDCONFIRMED DURING THE MANDATORY CONSTRUCTION KICKOFF MEETING PRIOR TOPERFORMING ANY WORK. TYPICAL LOCATION SHALL BE APPROXIMATELY FIVE FEETFROM PRESENTATION WALL. USE CEILING MOUNT WITH TILE BRIDGE AND SAFETYCABLE AS REQUIRED.
TE03 PROVIDE EMPTY 4 11/16" DEVICE BOX WITH SINGLE GANG MUD RING AND BLANKCOVER PLATE FOR FUTURE CAMERA INTERFACE ADJACENT TO SCREEN. LOCATEIMMEDIATELY ABOVE WRITING SURFACE APPROXIMATELY (7) SEVEN FEET (6) SIXINCHES AFF. LOCATE TO SIDE OF SCREEN NEAREST LECTERN APPROXIMATELY (1)ONE FOOT FROM EDGE OF SCREEN.
TE05 AS ROOM LAYOUTS VARY, LOCATIONS SHALL BE REVIEWED AND CONFIRMED DURINGTHE MANDATORY CONSTRUCTION KICKOFF MEETING PRIOR TO PERFORMING ANYWORK. REFER TO RISER DIAGRAM ON TECHNOLOGY SPACE PLAN AND DETAILTA-IFER FOR GENERAL INFORMATION AND REQUIREMENTS. THE TYPICAL ORDER OFOUTLET BOXES FROM FRONT TO BACK OF THE ROOM SHALL BE: SCREEN SWITCH,TELEPHONE OUTLET, DATA OUTLET, AV INTERFACE PLATES, THEN ELECTRICALOUTLET.
A
A
A
A
A
IF IF IF
AA
A
A
A REVIEW ALL CONTRACT DOCUMENTS FOR PROJECT REQUIREMENTS. TECHNOLOGY SPACEPLANS MAY NOT BE PROVIDED FOR ALL SYSTEMS AND ARE NOT EXHAUSTIVE. INFORMATIONPROVIDED IS PROGRAMMATIC; SOME ANCILLARY EQUIPMENT MAY BE SHOWN HEREIN FORCLARITY, BUT NOT ALL ANCILLARY EQUIPMENT IS SPECIFIED. PROVIDE ALL COMPONENTSNECESSARY FOR A FULLY FUNCTIONAL SYSTEM(S) READY FOR THE OWNERS USE.REQUIREMENTS FOR POWER, MOUNTING, CABLE MANAGEMENT, COOLING, AND OTHERMISCELLANEOUS COMPONENTS REQUIRED FOR A FULLY FUNCTIONING SYSTEM ARE ASSUMEDAND SHALL BE PROVIDED BY THE CONTRACTOR.
TO NETWORKBY OTHERS
TO NETWORKBY OTHERS
TO NETWORKBY OTHERS
TO NETWORKBY OTHERS
8 OHM
8 OHM
(EXISTING) (EXISTING)
SMARTLECTURN
CABLE POCKET
DETAILAV-D1
TO NETWORKBY OTHERS
L/R/C & SURROUND(QTY. 7)
TO NETWORKBY OTHERS
CC
16:10 ELECTRIC
RECESSED
SCREEN
*
57.5" x 92"
TENSIONED
ADVANTAGE 109"
DIAGONAL
SCREEN SWITCH
*
AS REQUIRED
COMPUTER(OFCI)
ASSISTEDLISTENING
SYSTEM(OFOI)
SMART LECTERN
MT-400-UCCS-MAPLE-NATURAL -7302
BLU-RAY PLAYER
*
DN-500BD
DIGITALMEDIA
PRESENTATION
SYSTEM
*
DMPS3-4k-150-C
TOUCHPANEL 7"
*
TSW-752
TABLE STAND
KIT
FOR TSW-750
TSW-750-TTK-X-S
DOCUMENT
CAMERA
*
VZ-3
POE SWITCH 5
PORT
CEN-SW-POE-5PROJECTOR
*
G6470WU
CEILING
SUBWOOFER
*
CONTROL 312CS
SURROUND
SOUND
PROCESSOR
*
HD-XSP
8 CHANNEL AUDIO
AMPLIFIER
*
DCi 8 | 300
WALL SURFACE
LOUDSPEAKER
*
CDD5x
CEILING SUB WOOFER -
BACKBOX
MTC-300BB12
CEILING SUB WOOFER -
GRILLE
MTC-300SG12
HDBT
INTERFACE
PLATE
CUSTOM
As Required
HDMI SWITCHER -
4K
*
HD-MD4X1-4K-3
APPLE TV
*
APPLE TV
SPKR
HDBT
HDMI
HDMI
CC
USB
CC
HDMI
RS232
IP
POE
IP
IP
IP
LM (QTY. 8)
SPKR
HDMI
MIC
LM (FROM HD-XSP)
VGA
LL LR
CV
LL LR
LM
IP
HDMI
HDMI
HDMI IP
IP
TYPE DESCRIPTION MANUFACTURER PART NUMBER SPECIAL RQMTS
SURROUND SOUND PROCESSOR CRESTRON HD-XSP
8 CHANNEL AUDIO AMPLIFIER CROWN DCi 8 | 300
S
CEILING SUBWOOFER JBL CONTROL 312CS
CEILING SUB WOOFER - BACKBOX JBL MTC-300BB12
CEILING SUB WOOFER - GRILLE JBL MTC-300SG12
WALL SURFACE LOUDSPEAKER MARTIN CDD5x MOUNTING BRACKET AS REQ.
DOCUMENT CAMERA WOLFVISION VZ-3
BLU-RAY PLAYER DENON DN-500BD
HDMI SWITCHER - 4K CRESTRON HD-MD4X1-4K-3
DIGITALMEDIA PRESENTATION SYSTEM CRESTRON DMPS3-4k-150-C
A PROJECTOR EPSON G6470WU
APPLE TV APPLE APPLE TV
TOUCHPANEL 7" CRESTRON TSW-752
TABLE STAND KIT FOR TSW-750 CRESTRON TSW-750-TTK-X-S
POE SWITCH 5 PORT CRESTRON CEN-SW-POE-5
SMART LECTERN ATF MT-400-UCCS-MAPLE-NATURAL-7302
POWER CONDITIONER FURMAN P-8 PRO II AS REQUIRED
INTERFACE PLATE CUSTOM RCI CUSTOM As Required
SPEAKON NEUTRIK As Required
ETHERCON CAT6A SHIELDED NEUTRIK As Required For Digital Media
Net Connect Cable XG620 4pr 23 AWG CMP Yellow Jacket AMP 4-1499416-7 For Digital Media
DISPLAY POLE MOUNTING HARDWARE CHIEF AS REQUIRED REUSE EXISTING
PROJECTOR MOUNT CHIEF RPAU REUSE EXISTING
T4.022
TE02
TE03
A
TE02
TE02
TE02S
B
61W
2
STA03
TA03
TE01
TE01
TE01
TA01
TE05
TA01
FLOOR
CEILING
A.
B.
C.
ALL MEASUREMENTS ARE TO CENTER UNLESS OTHERWISE NOTED.
STUB ALL CONDUITS TO ACCESSIBLE CEILING SPACE OF SAME ROOMUNLESS OTHERWISE ILLUSTRATED/NOTED IN RISER DIAGRAM.
ADDITIONAL CONDUITS FOR TELECOMM OR POWER MAY BE REQUIRED.REFERENCE DEVICE DETAILS AND TELECOMM AND ELECTRICAL PLANS.
RISER GENERAL NOTES
(1) 3/4-INCH CONDUIT
+90"(2) 1-INCH CONDUITS
IF
(2) 1 1/4-INCH CONDUITS
+18" IF+18"
(2) 1 1/4-INCH CONDUITS
(REF. DETAIL TA-IFER)
2
IF+18"
A
(2) 1 1/4-INCH CONDUITS
1.
2.
REFER TO ENLARGED FLOOR PLAN AND RELEVENT KEYNOTES FORSPEAKER OUTLET BOX QUANTITY AND LOCATION INFORMATION.AUDIOVISUAL CONTRACTOR SHALL REVIEW SPEAKER MOUNTING BRACKETAND WIRE MANAGEMENT AND COORDINATE EXACT REQUIREMENTS WITHOWNER.
REFERENCE DETAIL TA-IFER FOR GENERAL LAYOUT INFORMATION ANDASSUMED ELECTRICAL AND TELECOMM REQUIREMENTS TO BE CONFIRMEDBY OWNER. PROVIDE A BLANK PLATE FOR ONE OF THE BOXES TO BE LEFTAS SPARE FOR FUTURE USE.
RISER DRAWING NOTES
A
1
(1) 3/4-INCH CONDUIT
GENERAL NOTES
EQUIPMENT SCHEDULE
© Copyright BCER Engineering Inc.
Copyright reserved. All parts of this drawing are the exclusive
property of BCER Engineering and shall not be used or
reproduced in any manner without express written consent.
Client:
Project #:
Designed By:
Drawn By:
Approved By:
Scale:
No DateDescription
ISSUE RECORD
100% CONSTRUCTION DOCUMENTS
10/23/2015
As indicated
TECHNOLOGY SPACEPLANS
UCCS
CO
LO
MB
INE
HA
LL A
UD
IOV
I SU
AL U
PG
RA
DE
S
RIMROCK
RIMROCK
81515004
UN
IVE
RS
ITY
OF C
OL
OR
AD
O C
OLO
RA
DO
SP
RIN
GS
RIMROCK
T4.02
AU
ST
IN B
LU
FF
S P
KW
Y, C
OLO
RA
DO
SP
RIN
GS
, C
O 8
091
8
N
0 4'4' 2'
T4.02
1/4" = 1'-0"
1 FILM SCREENING CLASSROOM ENLARGED FLOOR PLAN
0 4'4' 2'
T4.02
1/4" = 1'-0"
2 FILM SCREENING CLASSROOM PRESENTATION WALL ELEVATION
T4.02
3 FILM SCREENING CLASSROOM RISER DIAGRAM
T4.02
4 FILM SCREENING CLASSROOM ONE-LINE DIAGRAM
KEYNOTES
TA01 CENTER SPEAKER ON SCREEN AND LOCATE SPEAKER OUT OF LINE OF SIGHT FROMSEATED POSITION IN BACK ROW TO THE TOP OF PROJECTION SCREEN.
TA03 PROJECTOR SCREEN AND SWITCH ARE EXISTING TO REMAIN.
TE01 PROVIDE SPEAKER OUTLET BOXES WITH APPROPRIATE BACKING (AS REQUIRED)FOR CEILING SURFACE MOUNTED SPEAKERS. CENTER MIDDLE OUTLET BOXHORIZONTALLY ON SCREEN. LOCATE ALL THREE OUTLET BOXES (4) FOUR FEETFROM WEST (PRESENTATION) WALL. LOCATE LEFT AND RIGHT OUTLET BOXES (4)FOUR FEET FROM SIDE WALL. PROVIDE BACKING (AS REQUIRED) IMMEDIATELYADJACENT TO BOX AND EXTEND EAST (TOWARD CENTER OF ROOM) AS FAR ASDRYWALL SLOPE CONTINUES, APPROXIMATELY (7) SEVEN FEET FROM WEST(PRESENTATION) WALL.
TE02 LOCATE OUTLET BOX AS HIGH AS POSSIBLE ON WALL. COORDINATE LOCATION WITHAV CONTRACTOR PRIOR TO PERFORMING ANY WORK.
TE03 PROVIDE EMPTY 4 11/16" DEVICE BOX WITH SINGLE GANG MUD RING AND BLANKCOVER PLATE FOR FUTURE CAMERA INTERFACE ADJACENT TO SCREEN. LOCATEIMMEDIATELY ABOVE WRITING SURFACE APPROXIMATELY (7) SEVEN FEET (6) SIXINCHES AFF. LOCATE TO SIDE OF SCREEN NEAREST LECTERN APPROXIMATELY (1)ONE FOOT FROM EDGE OF SCREEN.
TE05 AS ROOM LAYOUTS VARY, LOCATIONS SHALL BE REVIEWED AND CONFIRMED DURINGTHE MANDATORY CONSTRUCTION KICKOFF MEETING PRIOR TO PERFORMING ANYWORK. REFER TO RISER DIAGRAM ON TECHNOLOGY SPACE PLAN AND DETAILTA-IFER FOR GENERAL INFORMATION AND REQUIREMENTS. THE TYPICAL ORDER OFOUTLET BOXES FROM FRONT TO BACK OF THE ROOM SHALL BE: SCREEN SWITCH,TELEPHONE OUTLET, DATA OUTLET, AV INTERFACE PLATES, THEN ELECTRICALOUTLET.
EXTRON AAP SCHEDULE
Qty Part # Model Name1 60-300-02 AAP 102
1 70-103-18 One XLR 3-pin Male to Solder Cups, One XLR 3-pin Female to Solder Cups - Neutrik
1 60-1346-02 USB PowerPlate 200 AAP (Single-space)
1 70-092-72 Three RCA Female to Solder Cup (Silkscreen)
SCALE:
BACK BOX DETAIL FOR AV LECTERN LOCATIONSNONE
TA-IFER
INSULATED THROATBUSHING
BEND RADIUS = 6x INTERNALDIAMETER
2 GANGMUDRING
STUB CONDUIT6-INCHES INTOACCESSIBLECEILING UNLESSOTHERWISENOTED
FLOOR(REF:ARCHITECTURAL)
AV OUTLET BOX4 11/16 - INCH SQUAREMIN 2 1/8 - INCH DEEP BOX
SEE AVRISER
DIAGRAM
TELECOM OUTLET BOX4 11/16 - INCH SQUAREMIN 2 1/8 - INCH DEEP BOX
DUPLEX POWERRECEPTACLE(REF: ELECTRICAL)
1 GANGMUDRING
16" O.C.TYP.
FRAMING
CEILING LEVEL(REF:ARCHITECTURAL)
WALL(REF:ARCHITECTURAL)
#
MATCH TOLIGHT
SWITCHMOUNTING
HEIGHT
A. LOCATIONS SHALL BE REVIEWED ANDCONFIRMED DURING THE MANDATORYCONSTRUCTION KICKOFF MEETING. REFERTO RISER DIAGRAM AND TECHNOLOGYFLOOR PLAN FOR ADDITIONALINFORMATION AND REQUIREMENTS.
DETAIL GENERAL NOTES
TELECOM OUTLET BOX4 11/16 - INCH SQUAREMIN 2 1/8 - INCH DEEP BOX
#
INSULATED THROATBUSHING
BEND RADIUS = 6x INTERNALDIAMETER
2 GANGMUDRING
STUB CONDUIT6-INCHES INTOACCESSIBLE CEILINGUNLESS OTHERWISENOTED
AV CABLING
SCALE:
BACK BOX DETAIL FOR AV WALL INTERFACENONE
TA-IFW
AV OUTLET BOX4 11/16 - INCH SQUAREMIN 2 1/8 - INCH DEEP BOX
AVC AVC
IF
SEE AVRISER
DIAGRAM
FLOOR(REF:ARCHITECTURAL)
CEILING LEVEL(REF:ARCHITECTURAL)
WALL(REF:ARCHITECTURAL)
SCALE:
CEILING SPEAKER DETAILSNONE
TA-CSD
TRIM RING
LOUDSPEAKERCUTOUT AREA
LOUDSPEAKER
AVC AVCAVC AVC
AVC AVC
CONDUIT
4" x 4"ELECTRICAL BOX
LOUDSPEAKERCABLE
EC EC
EC EC
A
A.
B.
C.
LOCATE ELECTRICAL BOX AND CONDUITOUTSIDE OF LOUDSPEAKER CUTOUT AREA.COORDINATE WITH AUDIO VISUAL CONTRACTORPRIOR TO CONDUIT INSTALLATION.
MOUNT EYE BOLT ONTO CUSTOMMANUFACTURED DEVICE BOX FACEPLATE.FACEPLATE MADE OF 1/8-INCH ALUMINUM WITH1/2-INCH PASS THRU HOLE FOR CABLE SET OFFCENTER.
UTILIZE THEATER GRADE RIGGING HARDWAREINCLUDING BUT NOT LIMITED TO: AIRCRAFTCABLE, CABLE CLIPS, CABLE THIMBLES AND EYEBOLTS.
DETAIL GENERAL NOTES
FORGEDEYE BOLT
AIRCRAFT CABLE
THREADED ROD
FACEPLATE
CEILING FANTYPE DEVICEBOX
CONDUIT
CEILING(REF: ARCHITECTURAL)LOUDSPEAKER
CABLE
LOUDSPEAKERCABLE
TO STRUCTURE
HANGER WIRE
TILE BRIDGE
LOUDSPEAKERCUTOUT AREA
AVC AVC
AVC AVC
ACCESSIBLE CEILING(REF: ARCHITECTURAL)
LOUDSPEAKER
AVC AVC
LOUDSPEAKER
AVC AVC
AVC AVC
AVC AVC
AVC AVC
AVC AVC
ACCESSIBLE CEILING NON-ACCESSIBLE CEILING
PENDANT CEILING
PA NA
NON-ACCESSIBLE CEILING(REF: ARCHITECTURAL)
A A
A
N
P
EC EC
AIRCRAFT CABLETO STRUCTURE
AVC AVC
SCALE:
CEILING RECESSED SCREEN DTL.NONE
TA-CRS
UNISTRUTSTRUCTURALSUPPORT ONEFOOT LONGERTHAN CASE
THREADEDROD
MOUNT TOUNISTRUTSUPPORT
CONNECTPOWER TOSCREEN OR LOWVOLTAGECONTROLLER ASREQUIRED(REF:ELECTRICAL)
CEILING(REF:ARCHITECTURAL)
ATTACH TOSTRUCTURE
SCREEN -BOTTOM OFVIEWABLEAREA SHALLBE 48" AFFUON. PROVIDEEXTRA DROPAS REQUIRED.
AVC AVC
AVC AVC
INSULATED THROATBUSHING
BEND RADIUS = 6x INTERNALDIAMETER
MUDRING(REF: TABLE FOR SIZE)
STUB CONDUIT6-INCHES INTOACCESSIBLE CEILINGUNLESS OTHERWISENOTED
AV CABLING
SCALE:
BACK BOX DETAIL FOR AV WALL INTERFACE REQUIRING BACKINGNONE
TA-IFB
AV OUTLET BOXMIN 2 1/8 - INCH DEEP BOX
AVC AVC
16" O.C.TYP.
FRAMING(REF: ARCHITECTURAL)
BACKINGBOARD
AA A
TYPE BOX
-- 2
A 2
-- --
MUDRING
2
1
--
GANG SIZE
SEE AVRISER
DIAGRAM
GC GC
FLOOR(REF:ARCHITECTURAL)
CEILING LEVEL(REF:ARCHITECTURAL)
WALL(REF:ARCHITECTURAL)
SCALE:
BACK BOX DETAIL FOR AV DEVICE CONTROLNONE
TA-VCW
MATCH TOLIGHT
SWITCHMOUNTING
HEIGHT
FLOOR(REF:ARCHITECTURAL)
CEILING LEVEL(REF:ARCHITECTURAL)
WALL(REF:ARCHITECTURAL)
INSULATED THROATBUSHING
BEND RADIUS = 6x INTERNALDIAMETER
1 GANGMUDRING
STUB CONDUIT6-INCHES INTOACCESSIBLE CEILINGUNLESS OTHERWISENOTED
AV CABLING
AV OUTLET BOX4 11/16 - INCH SQUAREMIN 2 1/8 - INCH DEEP BOX
AVC AVC
A VCA S
SCALE:
TABLE TOP INTERFACE DETAILNONE
TA-TTIF IF T
© Copyright BCER Engineering Inc.
Copyright reserved. All parts of this drawing are the exclusive
property of BCER Engineering and shall not be used or
reproduced in any manner without express written consent.
Client:
Project #:
Designed By:
Drawn By:
Approved By:
Scale:
No DateDescription
ISSUE RECORD
100% CONSTRUCTION DOCUMENTS
10/23/2015
As indicated
TECHNOLOGY DETAILS
UCCS
CO
LO
MB
INE
HA
LL A
UD
IOV
I SU
AL U
PG
RA
DE
S
RIMROCK
RIMROCK
81515004
UN
IV
ER
SIT
Y O
F C
OL
OR
AD
O C
OLO
RA
DO
SP
RIN
GS
RIMROCK
T5.01
AU
ST
IN B
LU
FF
S P
KW
Y, C
OLO
RA
DO
SP
RIN
GS
, C
O 8
091
8
SCALE:
PROJECTOR MOUNT DETAILSNONE
TA-PMD
FRONT VIEW
FRONT VIEW FRONT VIEWFRONT VIEW
PLENUM CEILING
ACCESSIBLE CEILING EXPOSED CEILINGNON-ACCESSIBLE CEILING
CEILING TILE(REF: ARCHITECTURAL)
POLE
AVC AVC
PROJECTOR MOUNT
AVC AVC
PROJECTOR
AVC AVC
CEILING GRID(REF: ARCHITECTURAL)
POWER(REF: ELECTRICAL)
AV CABLING
AVC AVC
TELECOM OUTLET BOX4 11/16 - INCH SQUARE1 GANG MUD RINGMIN 2 1/8 - INCH DEEP BOX
DUPLEX POWERRECEPTACLE(REF: ELECTRICAL)
E
A.
B.
C.
D.
E.
F.
UNI-STRUT FRAMEWORK SHOULD BE PROVIDED TOALLOW PROJECTOR TO BE MOUNTED ANYWHERE INFRONT HALF OF THROW RANGE OF SPECIFIEDPROJECTOR AND LENS.
COORDINATE WITH ARCHITECT AND AUDIOVISUALCONTRACTOR FOR PROJECTOR PLACEMENT PRIORTO INSTALLING PROJECTOR STRUCTURAL SUPPORT.
USE RIGID CONDUIT FOR ALL OUTLET BOXES.
MOUNT PROJECTOR IN SUCH A WAY AS NOT TO BEOBSTRUCTED BY LIGHT FIXTURES, SPRINKLERHEADS, ETC.
DIGITAL KEYSTONE CORRECTION SHALL NOT BEUSED. PROJECTOR SHALL BE LOCATED ANDADJUSTED FIRST BY MOUNT THEN BY OPTICALADJUSTMENT(S) SO THE IMAGE IS FREE OF ANYKEYSTONING OR OTHER DISTORTION AND FILLSPROJECTION SCREEN/AREA.
MOUNT PROJECTOR AS CLOSE TO THE CEILING ASPOSSIBLE. REFER TO GENERAL NOTES D AND EAND ARCHITECTURAL DRAWINGS.
DETAIL GENERAL NOTES
N
CEILING TILE(REF: ARCHITECTURAL)
POLE MOUNT
AVC AVC
THREADEDROD
CEILING GRID(REF: ARCHITECTURAL)
DUPLEX POWERRECEPTACLE(REF: ELECTRICAL)
POLE
ESCUTCHEON RING
AVC AVC
AVC AVC
AV OUTLET BOX4 11/16 - INCH SQUARE2 GANG MUD RINGMIN 2 1/8 - INCH DEEP BOX
TELECOM OUTLET BOX4 11/16 - INCH SQUARE1 GANG MUD RINGMIN 2 1/8 - INCH DEEP BOX
THREADED ROD
FIXED CEILING(REF: ARCHITECTURAL)
POLE MOUNT
AVC AVC
AV OUTLET BOX4 11/16 - INCH SQUARE2 GANG MUD RINGMIN 2 1/8 - INCH DEEP BOX
TELECOM OUTLET BOX4 11/16 - INCH SQUARE1 GANG MUD RINGMIN 2 1/8 - INCH DEEP BOX
THREADEDROD
DUPLEX POWERRECEPTACLE(REF: ELECTRICAL)
POLE
ESCUTCHEON RING
AVC AVC
AVC AVC
PROJECTOR MOUNTNOT SHOWN
PROJECTOR MOUNTNOT SHOWN
PROJECTOR MOUNTNOT SHOWN
A N E
A
THREADED RODMOUNTING KIT
EDGE-PROTECTEDBUNDLED CABLE INLETCAVITY ON EACH SIDEOF BOX, FILLED WITHFLAME RETARDANTFOAM SEAL
KNOCKOUTFOR TELECOM UNI-STRUT
STRUCTURALSUPPORT FRAME
POLE
UNI-STRUTSTRUCTURALSUPPORT FRAME
POLE MOUNT
AVC AVC
AVC AVC
AV CABLING
AVC AVC
UNI-STRUTSTRUCTURALSUPPORT FRAME
ATTACH TOSTRUCTURE
ATTACH TOSTRUCTURE
ATTACH TOSTRUCTURE
ATTACH TOSTRUCTURE
ATTACH TOSTRUCTURE
ATTACH TOSTRUCTURE
ATTACH TOSTRUCTURE
ATTACH TOSTRUCTURE
#
#
THREADED ROD
#
# # #
#
#
# ###
EC EC
PLENUM ENCLOSURE(REF AV TECHNOLOGY PLANS)
BOTTOM VIEW BOTTOM VIEW BOTTOM VIEWSCREEN SCREEN SCREEN
CEILINGPLATE
AVC AVC
1
1. REUSE EXISTING PROJECTOR MOUNTINGSTRUCTURE. PROVIDE NEW TELECOM OUTLETBOX.
DETAIL DRAWING NOTES
© Copyright BCER Engineering Inc.
Copyright reserved. All parts of this drawing are the exclusive
property of BCER Engineering and shall not be used or
reproduced in any manner without express written consent.
Client:
Project #:
Designed By:
Drawn By:
Approved By:
Scale:
No DateDescription
ISSUE RECORD
100% CONSTRUCTION DOCUMENTS
10/23/2015
NONE
TECHNOLOGY DETAILS
UCCS
CO
LO
MB
INE
HA
LL A
UD
IOV
I SU
AL U
PG
RA
DE
S
Author
Designer
81515004
UN
IV
ER
SIT
Y O
F C
OL
OR
AD
O C
OLO
RA
DO
SP
RIN
GS
Approver
T5.02
AU
ST
IN B
LU
FF
S P
KW
Y, C
OLO
RA
DO
SP
RIN
GS
, C
O 8
091
8