DART
Digital Access Radio Technology
User Manual
8/10/2019 Dart DMC
2/161
8/10/2019 Dart DMC
3/161
DMC Stratex Networks
DARTUser Manual 850-900203-001, Rev D
Copyright 2001 by DMC Stratex Networks.
All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrievalsystem, or translated into any language or computer language, in any form or by any means, electronic,magnetic, optical, chemical, manual or otherwise, without the prior written permission of DMC Stratex Networks.
Printed in the United States of America.
DISCLAIMER
DMC Stratex Networks makes no representation or warranties with respect to the contents hereof andspecifically disclaims any implied warranties or merchantability or fitness for any particular purpose. Further,
DMC Stratex Networks reserves the right to revise this publication and to make changes from time to time in thecontent hereof without obligation of DMC Stratex Networks to notify any person of such revision or changes.
TRADEMARK
DART is a registered trademark of DMC Stratex Networks. All other product names are trademarks or registeredtrademarks of their respective companies.
8/10/2019 Dart DMC
4/161
DMC Stratex Networks
850-900203-001, Rev. D DARTUser Manual
This page intentionally left blank.
8/10/2019 Dart DMC
5/161
DMC Stratex Networks
DARTUser Manual Contents pg. i
850-900203-001, Rev. D
Contents
Contents i
1. Introduction to DART 1
1.1Product Overview .................................................................................................................1
1.2Configure & Monitor Dart by Computer .......... ........... .......... ........... .......... ........... .......... ..... 2
1.3Architecture and Components...............................................................................................3
Surge Protection...................................................................................................3
Theory of Operation.............................................................................................4
Transceiver Module..............................................................................................4
Main Board...........................................................................................................5
Power Supply - Main Board....................................................................... 5
Cable Interface - Main Board.....................................................................5
Microprocessor - Main Board ....................................................................5Digital-to-Analog (D/A) Converter - Main Board......................................6
Analog-to-Digital (A/D) Converter - Main Board......................................6
Transmitter - Main Board...........................................................................6
Receiver - Main Board ...............................................................................7
Field Programmable Gate Array (FPGA)...................................................7
1.4Accessories ...........................................................................................................................7
Optional ODU Cables ..........................................................................................7
Optional Antennas and Remote ODU Mount.......................................................9
1.5Options................................................................................................................................10
Optional Cable Termination Unit (CTU) ...........................................................10
Optional Cable Termination Strip (CTS) ...........................................................12
Optional Network Management Interface (NMI)...............................................13
2.Install DART Hardware 152.1Install the Antenna and DART Radio.................................................................................15
Tools required for terminal installation..............................................................15
Prepare for installation .......................................................................................16
Mount ODU to Antenna..................................................................................... 17
Integral Mounting (XP-Type Slip-Fit Antenna Interface)........................17
Remote Mounting (Waveguide Type Antenna Interface) .......... ........... ... 18
Connect the ODU cable......................................................................................19
Align the antenna................................................................................................20
2.2Install DART Accessories and Options ..............................................................................22
Deluxe CTU .......................................................................................................23
Install the Optional Deluxe Cable Termination Unit (CTU) ........... ......... 23
Standard CTU.....................................................................................................26
Standard CTU Installation Balanced (E1/DS-1), Unbalanced (E1),
and Ethernet CTU 10 Base-T ...................................................................26
Terminate the DART Standard CTU to the ODU Cable..........................27
CTS (Cable Termination Strip) ..........................................................................32
CTS Mounting Bracket Orientation Options............................................32
Install the CTS....................................................................................................32
2.3Cable Assembly Procedure - Detailed Instructions.............................................................34
Pin connections for female connector on ODU end.......... .......... ........... .. 37
Pin connection for male connector on inside end.....................................38
8/10/2019 Dart DMC
6/161
DMC Stratex Networks
ii Contents DARTUser Manual
3.Load LinkView Software & Connect to DART 41
3.1Configuration requirements.................................................................................................41
3.2Install LinkView on a PC....................................................................................................41
Installing from disk...................................................................................42
Installing from CD-ROM..........................................................................42
3.3Connect LinkView to DART via Cable .......... ........... .......... ........... .......... ........... .......... .....45
LinkView Connection to Inside End of ODU Cable withoutOptional CTU/CTS Interface..............................................................................45
Connection through Optional CTU/CTS ........... .......... ........... .......... ........... .......46
Verify Successful Serial Cable connection.........................................................46
3.4Connect LinkView to DART via Modem .......... .......... ........... ........... .......... ........... .......... ..47
Configure the modems........................................................................................47
Configuring the Modem on the Computer Side........................................47
Configuring the Modem at the Radio Side .......... .......... ........... .......... ......47
Ensuring the Modem is Installed Properly................................................55
4.Set Security with LinkView 57
4.1Security Levels....................................................................................................................57
4.2Changing Passwords ...........................................................................................................58
5.LinkView Startup & Tour 63
5.1Start the LinkView Software...............................................................................................63
Start LinkView Using a Serial Cable Connection...............................................63
Start LinkView using a Modem..........................................................................64
5.2Log-in and Log-out .............................................................................................................66
Log into the radio................................................................................................66
Log out of the radio ............................................................................................67
Disconnect the Phone Call........................................................................67
5.3 Screen Tour ........................................................................................................................68
5.4 Using Help .........................................................................................................................69
Help Menu..........................................................................................................69
Context Sensitive Help .......................................................................................69
5.5 Shortcuts and other display options....................................................................................70
Shortcut Toolbar:................................................................................................70
Status Bar............................................................................................................71
Window ..............................................................................................................71
5.6 Menu Commands ...............................................................................................................71
File Menu............................................................................................................72
Login Menu ........................................................................................................72
Monitor Log........................................................................................................72
Tools Menu.........................................................................................................72
Windows Menu...................................................................................................74
Help Menu..........................................................................................................74
6. DART with LinkView 75
6.1 View and Configure Radio Parameters .......... .......... ........... .......... ........... .......... ........... .....75
Configuration Tabs .............................................................................................75
General Configuration (Local and Remote)........................................................76
Change the Frequency ..............................................................................76
Change the Link ID...................................................................................77
Change the Transmit Power......................................................................78
Change the Site and Corporate Names ........... .......... ........... .......... ...........79
Alarm Windows..................................................................................................80
Alarm Configuration (Local and Remote) .......... ........... .......... ........... .......... ......80
8/10/2019 Dart DMC
7/161
DMC Stratex Networks
DARTUser Manual Contents pg. iii
850-900203-001, Rev. D
Change the Tributary Configuration.........................................................82
SNMP Configuration (Local and Remote).........................................................85
Configure Port 1 .......................................................................................85
Configure Port 2 (Ethernet)......................................................................87
Configure Port 2 (Serial Port) ..................................................................88
Configure the Radio Port..........................................................................89
Configure the SNMP Clock......................................................................90
View the SNMP Event Log......................................................................91
6.2 Use File Configuration Shortcut ........................................................................................91
Create a Configuration file.................................................................................92
Open an existing Configuration file ...................................................................93
Write a Configuration file to a DART Radio ........... .......... ........... .......... ........... 94
Print Configuration Reports ...............................................................................95
7. Monitor, Edit, & Troubleshoot DART with LinkView 97
7.1 Monitor DART events .......................................................................................................97
Monitor Log Overview.......................................................................................97
View Monitor Log..............................................................................................98
Edit Monitor List................................................................................................99
Set up a Monitor Session..................................................................................100Read Link.........................................................................................................101
7.2 Edit the Radio Frequency Plan ........................................................................................102
7.3 Download radio software through LinkView ......... ........... ........... .......... ........... .......... .... 103
Determine the Active Software Version...........................................................105
7.4 View Device Attributes....................................................................................................106
7.5 Troubleshoot DART with LinkView...............................................................................107
Diagnostic Tools ..............................................................................................107
Digital Loopback:.............................................................................................108
Tributary Loopback:.........................................................................................108
Forward Error Correction (FEC)......................................................................109
Modulation: ......................................................................................................110
Unmute Remote................................................................................................111
7.6 LinkView Frequently Asked Questions...........................................................................111
7.7 Troubleshooting Alarms ..................................................................................................112
8. DART Radio Specifications 114
9. DART Product Ordering Guide 115
9.1 Ordering Considerations for DART Radios.....................................................................115
9.2 DART Outdoor Unit (ODU) Selection:........... .......... ........... .......... ........... .......... ........... .117
9.3 Antenna Selection:...........................................................................................................118
9.4 DART Options:................................................................................................................120
ODU Cable Indoor Termination Options:........................................................120
Cable Termination Units (CTUs) ..................................................................... 120
CTU Configuration Jumpers ............................................................................121
E1 CSU/DSU (V.35)........................................................................................122Cable Termination Strip (CTS) ........................................................................122
Network Management Option: .........................................................................123
9.5 DART Accessories: .........................................................................................................125
Cables/Connectors:...........................................................................................125
DART ODU cables ................................................................................125
DART ODU-CTU-CTS Connectors: .....................................................128
9.6 Hardware Installation Tools:............................................................................................128
9.7 Software Installation Kit (LinkView): .......... ........... .......... ........... .......... ........... ........... ... 129
Software Installation Toolkits (LinkView).......................................................129
8/10/2019 Dart DMC
8/161
DMC Stratex Networks
iv Contents DARTUser Manual
LinkView Cables ..............................................................................................129
Software:...........................................................................................................130
9.8 Rack Assembly Installation:.............................................................................................130
9.9 Documentation:................................................................................................................130
9.10 AC/DC Converter Options:............................................................................................131
9.11 Lightning Surge Protection Junction Box: ........... .......... ........... .......... ........... .......... ......132
9.12 Test Fixtures:..................................................................................................................132
9.13 Other Accessories:..........................................................................................................133
10. Installation Guides 135
10.1 Radio..................................................................................................................... .........135
10.2 CTS (Cable Termination Strip) .......... ........... .......... ........... .......... ........... .......... ........... ..137
DART Deluxe CTU ...............................................................................................................139
10.4 Standard CTU (Cable Termination Unit) .......... .......... ........... .......... ........... .......... .........141
10.5 Base-T CTU ...................................................................................................................143
11. Field Commissioning Test 145
12. Index 151
8/10/2019 Dart DMC
9/161
DMC Stratex Networks
DARTUser Manual Introduction 1
850-900203-001, Rev. D
1. Introduction to DART
Sections
1.1 Product Overview pg.1
1.2 Configure & Monitor Dart by Computer pg.2
1.3 Architecture and Components pg.3
1.4 Accessories pg.7
1.5 Options pg.10
1.1 Product OverviewThe DART digital microwave radio
available from DMC Stratex Networksprovides last-mile, wireless transmission for
point-to-point digital radio interconnection. It
offers an extremely cost-effective, all
outdoor, single E1 or DS-1 digital
microwave connection to applications
requiring modest data capacity. The DART
also provides an ideal leased line alternative.
The all-outdoor design makes the DART
radio an ideal complement to the new
generation of microcell/picocell, all-outdoor base stations that cannot accommodate
the indoor units of traditional microwave radio systems. It also provides network
service providers and enterprise network managers with a competitive solution toleased-lines. DART radios allow connection of a customers network without the
aggravation and costs associated with the use of incumbent carrier wire-lines, or the
high costs associated with self-installation of wire or fiber connections.
The DART radio is designed for use in licensed bands for fixed wireless
transmission. To safeguard your capital investment in equipment, it protects againstinterference from other wireless systems. With todays streamlined licensing process,
a license to operate a wireless system can be obtained in less than a week in most
cases, all while the system installation is in progress. DARTs advantages over
unlicensed wireless systems include greater availability of the link, longer life, less
interference from other systems and higher transmission integrity.
8/10/2019 Dart DMC
10/161
DMC Stratex Networks
2 Introduction DARTUser Manual
1.2 Configure & Monitor Dart by ComputerFor simplified installation, commissioning, and maintenance, LinkView (the DMC
Stratex Networks radio software tool for DART) is used to configure and monitor the
DART radios. This eliminates the need for hardware switches or factory installed
options.A simple commissioning procedure allows you to configure both the local and
remote radios in minutes from one end of a functioning link. Parameters that can be
set with LinkView include:
transmit and receive frequencies
transmit power level
link ID codes
receive signal level (RSL)
bit error rate (BER) alarm limits
tributary loopbacks
LinkView can also be used to configure the local SNMP (Simple NetworkManagement Protocol) interface, IP address, subnet mask, and other settings to
efficiently manage your connections.
Once your system is configured, LinkView provides the ability to monitor and
change alarms, RSL, and BER at the local and remote ends. This information is
updated in real time. Diagnostic loopback capability is also provided.
Dartwith Optional
CTU/CTS
& LinkViewDigital Access
RadioTechnology
F U S E
A LA RM TRIB P O RT 2 P O RT 1
TRIBMONITOR OD
U
L E D
V
----- A LRM
P W R
!TX RX
RE LA Y
TX RX
LOCALODU
(SNMP OPTIONAL)
MulticonductorCable
CTU( OPTIONAL)
LAPTOP PCWITH LINKVIEW
F U S E
A LA RM TRIB P O RT 2 P O RT 1
TRIBMONITOR OD
U
L E D
V
----- A LRM
P W R
!TX RX
RE LA Y
TX RX
REMOTEODU
(SNMP OPTIONAL)
CTU( OPTIONAL)
LinkView
LOCAL TERMINAL REMOTE TERMINAL
LOCALANTENNA
REMOTEANTENNA
DS-1/E1 & Management Traffic
8/10/2019 Dart DMC
11/161
DMC Stratex Networks
DARTUser Manual Introduction 3
850-900203-001, Rev. D
1.3 Architecture and ComponentsThe DART is a single E1 or DS-1 digital radio system designed to meet
microcell/picocell and last-mile access requirements. The DART allows transmission
of a single E1 (2.048Mbps European Standard) or DS-1 (1.544Mbps North American
Standard) data stream through a radio contained in a compact outdoor unit (ODU).The ODU attaches directly to an antenna. Two antennas and two ODUs are required
to complete a point-to-point link.
DartOutdoor Unit
(ODU)Compact design
forconvenient,unobtrusiveinstallation
269 mm (10.6 in) 83 mm (3.3 in)
A DART terminal is an ODU (outdoor unit) and an antenna connected together at the
same location. The local terminal communicates with a remote terminal via radio
signals transmitted and received by the antennas. This configuration is known as alink and is identified by a link ID. The link ID is used to prevent interference betweendifferent links operating in the same geographic area.
Embedded DART code may be downloaded to local and remote ODUs usingLinkView, or via SNMP (Simple Network Management Protocol) through the
optional NMI (Network Management Interface).
Surge Protection
The DART ODU is designed with surge protection. The cable to the ODU has either
12 or 16 wires (6 or 8 twisted-pair cable. The 8 twisted-pair cable is required if the
optional NMI (Network Management Interface) card is installed. Each of the 16wires is protected with surge arrestors at the ODU. No additional surge protection is
required for typical DC line surges.
However, for areas prone to lightning, a Lightning Arrestor (LA) is suggested for
protection of components inside a building or shelter. Please contact your local DMC
Stratex Networks representative for assistance in selecting a lightning arrestor.
8/10/2019 Dart DMC
12/161
8/10/2019 Dart DMC
13/161
DMC Stratex Networks
DARTUser Manual Introduction 5
850-900203-001, Rev. D
detector, and a multiply-by-M (M dependent on ODU frequency) output that drives
the up- and down-conversion mixers for the transmitter and receiver. The
Intermediate Frequency (IF) drive for the transmitter is provided by the DART main
circuit board. The maximum IF drive level is nominally +7 dBm, and transmitter
output power variation is achieved by varying the IF drive level. This gives a
minimum transmitter output power range of -5 dBm to +15 dBm. The frequency of
the transmitter IF drive varies from 2-3GHz, depending on ODU frequency. The IF isFSK (Frequency Shift Key) modulated by the baseband transmit signal.
Main Board
The main board is divided into 6 major sub-sections: a power supply, a cable
interface, a microprocessor, a Field Programmable Gate Array (FPGA), a transmitter,
and a receiver.
Power Supply - Main Board
The power supply accepts +/-24 to +/-60 VDC. Power consumption of theDART radio is typically 30 watts (35 watts with NMI option). Ripple
tolerance is 200mv p-p, 50 Hz to 20 kHz. A switching power supply
module on the main board regulates the output voltages. To further reduce
power supply noise on the board, output voltages are also regulated by linear
mode regulators. Supply output voltages are +12V, +5V, and -5V. The +5V
supply is split into three separate supplies. Two of these supplies drive the
transceiver module (one for the transmitter power amplifier, one for the
VCO and other circuitry), and one drives the PCA (Printed CircuitAssembly) logic. Heat sinking for both linear and switching regulators is
provided by the massive baseplate, which is a very efficient heat dissipater.
Cable Interface - Main BoardThe cable interface consists primarily of level translators that shift TTL
(Transistor-Transistor Logic) level signals from the processor to RS422,
RS232, and E1/DS-1 levels for driving the cable. LinkView can be used to
select Port 1 (via DB-9 connection) and Port 2 (via RJ-45 connection)
functionality. Port 1 can be configured as either a LinkView interface port or
a SLIP/PPP network port. Port 2 can be configured as either a SLIP/PPP
port or a 10Base-T Ethernet port.
Microprocessor - Main Board
The microprocessor controls all the basic functions of the radio and providesa user interface to allow control and monitoring of all the vital radio
parameters. The embedded code for the microprocessor is stored in
electrically erasable memory, which allows the code to be updated in the
field without taking the unit out of service. Radio parameters are controlled
and monitored through digital input/output lines, 4 analog outputs, and 12
analog inputs. The microprocessor also communicates to the SNMP option
board and to the FPGA through dual port RAM devices. The SNMP
communication channel allows the processor to send and receive radio
8/10/2019 Dart DMC
14/161
DMC Stratex Networks
6 Introduction DARTUser Manual
parameters to and from a network via the SNMP option board. The FPGA
interface allows the processor to insert and extract data from the overhead
channel of the radio link. This allows the user to control and monitor both
sides of a radio link from a single location.
Digital-to-Analog (D/A) Converter - Main BoardThe output of the digital-to-analog converter (D/A) includes transmit power
control, transmitter modulation deviation, and AGC voltage output (with
respect to RSL). Transmit power control values are determined during
calibration and stored in the tombstone (a database stored in non-volatile
memory that contains the radio configuration parameters). The values,
ranging from 0 to 255 bits (corresponding to 0 to 5 Volts), are obtained at
three frequencies for each of three temperatures (cold, hot, and ambient).
AGC voltage output is proportional to received signal level. The voltage iscalibrated such that 1 VDC is equivalent to 80 dBm, with AGC voltage
increasing 0.1 V for each 1.0 dB increase in RSL up to 5 VDC (-40 dBm).
AGC (VDC) 1.0 2.0 3.0 3.5 4.0 4.5 5.0
RSL (dBm) -80 -70 -60 -55 -50 -45 -40
AGC/RSL Accuracy = 3dBm
Analog-to-Digital (A/D) Converter - Main Board
The input to the analog-to-digital converter (A/D) includes RSL calibration,
temperature sensor calibration and AGC output voltage from the D/A. RSL
calibration is a linearization of the AGC voltage for ease of use in tracking
the RSL. The values for RSL will be determined during factory calibration
at three frequencies for each of three different temperatures (cold, hot, andambient) and stored in the tombstone. The AGC output voltage from the
D/A is fed back to the A/D.
Transmitter - Main Board
NRZ (Non Return to Zero) data from the FPGA (the aggregate transmit databit stream) is fed to a variable gain amplifier. The modulation index of the
transmitted signal can be varied under microprocessor control by changing
the gain of this amplifier. The output of the amplifier drives the modulation
port of the transmit IF oscillator to generate an FSK modulated carrier at
around 2500 MHz. The carrier is phase-locked to a crystal reference for
stability. The carrier then passes through an attenuator circuit that iscontrolled by the microprocessor. The microprocessor controls the final
transmitter output power by varying the IF drive level. The carrier passes
through a final amplifier stage and a bandpass filter before going into the
transceiver IF input.
Linearizationof AGCVoltageand RSL
8/10/2019 Dart DMC
15/161
DMC Stratex Networks
DARTUser Manual Introduction 7
850-900203-001, Rev. D
Receiver - Main Board
The received IF (roughly 1750 MHz) from the transceiver module passes
through a bandpass filter into a 20 dB gain stage before entering the second
down-conversion mixer. The LO for the mixer is 70 MHz below the receive
IF and phase locked to a crystal reference. The resulting 70 MHz IF passes
through a SAW (surface acoustic wave) filter, which determines the overallselectivity and noise bandwidth of the receiver. The bandwidth of the SAW
filter is dependent on the data rate of the radio. The received signal goes into
an AGC (automatic gain control) amplifier with an AGC range of
approximately 60 dB. The AGC voltage is conditioned and sent to the
microprocessor for display of RSL. The IF signal then passes into a limiting
IF and quadrature demodulator circuit. The demodulated baseband signal is
amplified, converted to NRZ data, and then sent to a clock recovery circuit.
This baseband aggregate data stream is fed into the FPGA, where it is de-
scrambled, error corrected, de-multiplexed and routed out to the customer
data interface for DS-1/E1 data and to the microprocessor for overhead
processing.
Field Programmable Gate Array (FPGA)
The FPGA provides the multiplexing and de-multiplexing of overhead data
into the customer data stream, the scrambling and de-scrambling of the
aggregate data stream, the forward error correction (FEC - type: BCH)
encoding and decoding, the user port switching functions, and the logic for
various functions in the radio. The overhead data is comprised of framingand parity bits, FEC coding bits, inter-processor communication bits (so the
processors on each end of the radio link can communicate), stuffing bits to
compensate for transmit and receive clock frequency variation, and spare
bits for future expansion. The customer data runs through a first-in-first-out
(FIFO) buffer to smooth out the data transfer to and from the aggregate datastream.
1.4 Accessories
Optional ODU Cables
There are several ODU cable types available for purchase with DART radios.
The type of cable selected depends on the length of cable required, the inputvoltage, and both power consumption and power budget requirements for the
terminal. The power consumption specification of the DART radios is typically
30 watts per terminal. However, the cable will add further power dissipation,
depending upon the length and input voltage. A cable reference table is provided
for the recommended cable lengths for each voltage input and each cable
accessory (standard or custom cable) based upon a typical power budget (ODU
and cable) of 35 watts. This reference table should be used as a guide to
NOTE:Pre-terminated ODUcables are availablefrom DMC. Refer toChapter 9, DARTProduct OrderingGuide, for orderinginformation.
8/10/2019 Dart DMC
16/161
8/10/2019 Dart DMC
17/161
DMC Stratex Networks
DARTUser Manual Introduction 9
850-900203-001, Rev. D
50' 75' 100' 240' 300'
Std. Custom Std. Custom Std. Custom Std. Custom
+ or
24 VDC
38 W 38 W N/A N/A N/A N/A N/A N/A
+ or
48 VDC34 W 33 W 39 W 37 W 48 W 42 W N/A 44 W
+ or
60 VDC33 W 32.5 W 37 W 36 W 40 W 38 W 45 W 40 W
+ or
24 VDC
42 W(40')
42 W(62')
N/A N/A N/A N/A N/A N/A
+ or
48 VDC38 W 37 W 45 W 42 W 59 W 46 W N/A 50 W
+ or
60 VDC37 W 36.5 W 42 W 40 W 45 W 42 W 49 W 45 W
Optional Antennas and Remote ODU MountThe DART ODU attaches directly to an antenna (with an XP slip-fit connection) or
to a remote ODU mount. The antenna and remote mounts provide a weatherproof
connection and secure mounting (lockable) latches for the entire ODU. Typicalantenna sizes in the frequency bands for the DART are available from a variety of
antenna vendors. The antennas with the integral slip-fit connection are available for
the DART terminal from DMC Stratex Networks, and can be ordered at the same
time as the DART terminals and optional equipment. The remote mount for the
DART ODU requires an antenna with a waveguide type (versus an XP slip-fit) for
connection of a piece of flexible waveguide (1 foot to 4 feet available). The remote
mounting of the ODU is typically for inaccessible antenna installations or for
reducing the overall profile of the installation if required.
ODU &AntennaMounts
Antenna/Outdoor Unit(Odu) Slip Fit Mount
Remote Outdoor Unit(Odu) Mount
PowerDissipationRatios
8/10/2019 Dart DMC
18/161
DMC Stratex Networks
10 Introduction DARTUser Manual
1.5 Options
Optional Cable Termination Unit (CTU)
Optional CTUs are available for use with DART radios. The CTUs are designed toprovide specific interfaces. The CTUs provide a standard interface for
transmit/receive data, power, alarm summary, and management connections. They
act as a convenient method of terminating the DART ODU cable. These signals are
combined in a multi-pin cable connected to the DART radio. The CTUs also convert
the RS422 communications link from the ODU to RS232 for use with a standard
laptop. Two versions of cable termination units are available: Deluxe and Standard.
The Deluxe CTU is available as balanced (DS-1, E1) and unbalanced (E1). The
Standard CTU is available as balanced (DS-1, E1), E1CSU/DSU (V.35), unbalanced
(E1) or as Ethernet (10 Base-T). The Deluxe CTU was specifically designed for
customer applications requiring the ability to confirm customer traffic withoutinterruption (generally during trouble calls). The Standard CTU was designed to
standardize the unit across customer applications and minimize the size of the unit toallow for compact rack mounting (2 standard CTUs can be mounted in one 19-inch
rack unit).
Figure: Deluxe Cable Termination Unit(CTU) ba lanced wi th modem she l f
Figure: Deluxe Cable Termination Unit(CTU) unbalanced with modem shelf
Figure: Standard Cable Termination
Unit (CTU) balanced with modem shelf
Figure:Standard Cable Terminat ion Uni t(CTU) Unbalanced, wi th modem shel f
Figure: Standard Cable Terminat ion
Uni t 10 Base-T, wi th modem shel f
Figure: Standard Cable Termination Unit (CTU) two per 19" rack.
8/10/2019 Dart DMC
19/161
DMC Stratex Networks
DARTUser Manual Introduction 11
850-900203-001, Rev. D
E1 CSU/DSU(Loop V-35 Unit)
Front Panel
Back Panel
All CTU options can be installed into a standard 19" equipment rack. The Deluxe
CTU is provided with a modem shelf attachable to the CTU. The shelf is intended for
use with a standard, customer supplied modem. The Standard CTU is smaller in size
and is provided with a modem shelf (single CTU 19" rack mount) and a U bracket (2
Standard CTU racks mount in one 19" rack unit) for installation in a 19" rack. All
CTUs provide typical surge protection for each of the twisted pairs in the main ODU
cable.
Deluxe Cable
TerminationUnit (CTU)Balanced.
Available connections
ODU Cable Connector(18-p in Female)
Ground Lug
LinkView/SLIP/PPPPort
Traff ic PortRJ-45 Balanced orBNC Unba lanced
Input PowerConnector
3.15A Fuse
LED/RelaySwitch
Ethernet /SLIP/PPPSNMP Por t
Form C RelayContact
Tributary Monitor(Bantam Jacks)
8/10/2019 Dart DMC
20/161
DMC Stratex Networks
12 Introduction DARTUser Manual
Front Panel Connection DescriptionPower Connector(3-Pin Phoenix Type FemaleConnector)
24 to 60 VDC is required to power the CTU andODU.
Alarm Relay Outputs(2-Pin Phoenix Type FemaleConnector)
Normally open in the non-alarmed state and closedwhen an alarm is detected. This relay may beconfigured as either a terminal summary alarm or a
link summary alarm with the link managementsoftware tool, LinkView.
Tributary Data Ports(RJ-48 for Balanced DS-1/E1 Data)(Dual BNCs for Unbalanced E1Data)
Standard E1 CTUs may be ordered as either balancedor unbalanced.The DS-1 CTU is always balanced.
Management Port 1(DB-9 Female Connector)
May be configured as a LinkView port (RS232) or asan SNMP port (SLIP/PPP RS232).
Management Port 2(RJ-45 for Ethernet)(RJ-45 for Serial)
This is an SNMP port. May be configured as a serialport (RS232/RS422 SLIP/PPP) or as an Ethernet port(10Base-T).
Front Panel Connection Description
Military 18-Pin Connector Allows for rapid connect and disconnect of CTU.
Tributary Monitor Allows for noninterference traffic monitoring.
LED/Alarm
Allows switching between alarm relay signal and LED
on the front of the CTU for local (LED) or remote
(relay) radio monitoring.
Optional Cable Termination Strip (CTS)Optional cable termination strip (CTS) units are available for use with the DART
radios. The palm-sized CTS is designed to provide the user with a convenient and
compact means to terminate the DART radio cable, and provide standard connector
interfaces for the customer. The CTS provides a standard interface fortransmit/receive data, power, alarm summary, and management connections. Thesesignals are combined in a multi-pin cable connected to the DART radio. The CTS
provides an RS422 port for use with LinkView (port 1). An optional RS422 to RS232
cable is required for LinkView operation through the CTS (BNO port on ODU also
available).
CableTerminationStrip (CTS)Balanced andUnbalanced
The CTS is provided with rack mounting brackets. One of these brackets may be
rotated (360 degrees in 90 degree increments) on the CTS to allow installation into a19" rack or wall mounting in various configurations. The CTS provides typical surge
protection for each of the twisted pairs in the main radio cable. See the following
table for details.
StandardCable
TerminationUnit(CTU)
Connections
Deluxe Cable
TerminationUnit (CTU)Connections:
(front panelprovides all
Standard CTUconnections shown
above plus)
8/10/2019 Dart DMC
21/161
DMC Stratex Networks
DARTUser Manual Introduction 13
850-900203-001, Rev. D
Front Panel Connection Description
Power Connector(3-Pin Phoenix Type FemaleConnector)
24 to 60 VDC is required to power the CTS and ODU.
Alarm Relay Outputs(2-Pin Phoenix Type FemaleConnector)
Normally open in the non-alarmed state and closed whenan alarm is detected. This relay may be configured aseither a terminal summary alarm or a link summary alarm
with the link management software tool, LinkView.Tributary Data PortRJ-48 for Balanced Data-and-Dual BNCs for Unbalanced Data
Jumper selectable as balanced or unbalanced.
Management Port 1(DB-9 Female Connector)
May be configured as a LinkView port (RS422) or as anSNMP port (SLIP/PPP RS422).
Management Port 2(RJ-45 for Ethernet)(RJ-45 for Serial)
This is an SNMP port. May be configured as a serial port(RS422 SLIP/PPP) or as an Ethernet port (10Base-T).
Optional Network Management Interface (NMI)
The Network Management Interface (NMI), an optional Simple NetworkManagement Protocol (SNMP) interface card, is offered for the DART. The optional
NMI card is fully SNMP compliant and offers a standards-based open-system
network management solution allowing integration with an SNMP compliant
Network Management System (NMS). The optional NMI card is ordered from the
factory at the same time as the DART terminal, and is inserted in the ODU and tested
during production. The NMI card connections can be accessed through the ODU
cable or through one of the optional CTU/CTS termination devices.
Features Include:
Radio Configuration
Radio Status Monitoring
Radio In-Service Performance Monitoring Dial-Out Alarm (TRAP) Capability
Dial-In Capability (Via Customer Provided External Modem)
Radio Software Code Download
Radio Security Features
Standard MIB Available
SNMP Configuration
SNMP Software Code Download
SNMP Security
Alarm Management
The card is configured via LinkView software, after which the following three SNMP
ports are used to connect and manage a complete network.
Port 1: Software configurable as a serial port for NMS (SLIP/PPP and RS232) or
LinkView (RS232)
Port 2: Software configurable as a serial port (SLIP/PPP and RS232) or Ethernet (10
Base-T)
Radio Port (over the air overhead channel)
Connectionsprovided on
the frontpanel
of the CableTermination
Strip(CTS)
8/10/2019 Dart DMC
22/161
DMC Stratex Networks
14 Introduction DARTUser Manual
The optional NMI card implements IP (Internet Protocol) technology for addressing
and routing to and from the configured ports. A network can be configured as a
private Intranet, or it can be connected directly to the Internet. Password protection
keeps the system secure in either configuration. The open system concept of SNMP
allows the optional NMI card to be accessed with any SNMP MIB Browser
application.
The figures below show how typical NMI cards are set up for ODUs in a network
node interface and in a daisy chain configuration. Notice that not all DART ODUs
require optional NMI cards for network connectivity. If throughput of the SNMP
communications is not required (as would be required in daisy chain configurations),
the local ODU is capable of managing the remote ODU in a link.
Typical NMSNetwork
Node NMIConnections
S N M P
Manager
Node
CTU CTU
Term. Strip
Term.Strip
NMI-1
NMI-3
NMI-2
CT S CT S
Ethernet/ Serial
NMSNetwork
Daisy-ChainedNMI
S N M P
Manager
CT U
NMI-1
NMI-2
NMI-5
NMI-4
NMI-3
CT U CT SCT S
Term.Strip
Term.Str ip
Ethernet/ Ser ia l
Ethernet/Ser ia l
Ethernet/ Ser ia l
8/10/2019 Dart DMC
23/161
DART User Manual Install DARTpg. 15
850-900203-001, Rev. D
2. Install DART Hardware
Sections2.1 Install the Antenna and DART Radio pg. 15
2.2 Install DART Accessories and Options pg. 22
2.3 Cable Assembly Procedure - Detailed Instructions pg. 34
2.1 Install the Antenna and DART Radio
The following installation procedures assume that preplanning of the link, includingpath budgeting, antenna size and type, site surveys, frequency licensing, and
verification of clear line-of-sight between terminals has occurred.
This section includes details for installing and operating the DART terminal (ODU),
terminating the ODU cable at both ends, and installing any optional termination
equipment, such as CTUs or the CTS available from DMC Stratex Networks.
WARNING: Exercise proper ESD grounding precautions at all times whenaccessing CTU/CTS internal connectors and jumpers, and ODU cable
connectors.
Tools required for terminal installation
Basic electricians toolkit, including a multi-meter (voltmeter/ohmmeter).
Adjustable wrench (5-20mm).
Torque wrench (66 N-m / 50 ft-lb) with a inch socket.
Sufficient grounding cable to ground the ODU to a suitable earth ground at the ODUfor optional CTU/CTS. Recommended minimum is 9AWG (25mm
2).
Cable ties (various lengths).
Laptop PC with LinkView software installed.
One DB-9 to BNO cable to connect from the computer serial port to the ODU forconfiguration and set up (available in the LinkView Software Installation Kit from
DMC Stratex Networks).
One BNC to dual banana jack for monitoring AGC during antenna alignment.
Crimp and insertion tools for terminating the ODU cable with a Military typeconnector (available in an optional DMC Stratex Networks Installation Tool Kit,
product number 850-600403-001).
8/10/2019 Dart DMC
24/161
DMC Stratex Networks
pg. 16 Install DART DART User Manual
You also need these components that come with a DART Software
Installation Kit.
DART User Manual
LinkView Software
DB-9F to BNO Serial Cable
Refer to Chapter 9, DART ProductOrdering Guide, for ordering information on
hardware and software installation kits.
The DART ODU includes a Mil-style female connector for terminating the ODU
cable (ordered separately) for connection to the ODU. Similarly, the Deluxe CTU
(DS-1/E1) and the CTS include a Mil-style male connector for terminating the
ODU cable at the indoor end. The Standard CTU does not require a Mil-style
connector, as the ODU cable terminates directly to a terminal strip inside the unit.
Prepare for installationThe DART ODU (outdoor unit) may be used with an antenna that has the DMC
Stratex Networks customized (XP-type slip-fit) interface, or with a typical waveguide
type antenna interface. The ODU uses catches and spring-loaded retention clips on
the antenna interface to attach directly to an XP type slip-fit antenna. A remote ODU
mount option is available for standard waveguide connection to a standard waveguideantenna interface.
DARTsCompact
All-OutdoorDesign
269 mm (10.6 in) 83 mm (3.3 in)
The terminal can be configured using LinkView either before (for product protection
and safety, use suitable load devices on any open RF ports) or after mounting to the
antenna. If you decide to configure first, connect the LinkView cable (DB-9 to BNO)
from the serial computer port to the BNO connector on the ODU faceplate. See
8/10/2019 Dart DMC
25/161
DART User Manual Install DARTpg. 17
850-900203-001, Rev. D
Chapter 3, for instructions on installing LinkView on a PC and connecting to DART.
See Chapter 6 for instructions on configuring DART.
NOTE:
If a CTU (Cable Termination Unit) or a CTS (Cable Termination Strip) willserve as the connection point for the computer running LinkView, install that
equipment first. See Install DART Accessories & Options, page 22,forinstallation instructions.
Mount ODU to Antenna
Step 1. Install the antenna according to the antenna manufacturers instructionsincluded with the antenna.
Step 2. Choose between integral or remote mounting of the ODU to theantenna. Mount the ODU. The procedure for completing this step is
different, depending on whether you choose integral (slip-fit) or remotemounting.
Integral Mounting (XP-Type Slip-Fit Antenna Interface)
A. Attach the ODU to the antenna using the captive spring clips on
the antenna. The arrow on the label attached to the ODUs
baseplate indicates polarization.
B. A padlock can be used to ensure that the terminal is secured to
the antenna.
Antenna/ODUSlip-FitMount
8/10/2019 Dart DMC
26/161
DMC Stratex Networks
pg. 18 Install DART DART User Manual
Remote Mounting (Waveguide Type Antenna Interface)
Antenna/ODU Remote
Mount
O D U
Certain installations of the DART terminal require the ODU to be mounted
away from the antenna instead of using the integral XP type slip-fit. The
following instructions are for remote mounting of the DART ODU away
from a waveguide type antenna.
A. Order the optional remote mount kit (frequency band dependent)from DMC Stratex Networks and a suitable length of flexible
waveguide to connect the remote mount and ODU to a standard
waveguide type antenna with standard waveguide flanges. The
flexible waveguide is available in lengths from 1 to 4 feet (in
one-foot increments) for all DART frequency bands. Flexiblewaveguide with choke flanges, or other suitable flange with a
watertight seal, must be used to ensure the weatherproof integrity
of a DART remote mount installation.
B. Install the antenna per the manufacturers instructions included
with the antenna kit. Roughly align the antenna on the desiredpath.
C. Use the included hardware and instructions to install the remote
mount to the same or adjacent pole as the antenna. Mount the
remote mount within a distance that allows the flexible
waveguide to be installed and still have sufficient slack for
proper operation.
D. Install the flexible waveguide between the remote mount and the
antenna. Make sure to align the waveguide flanges so that the
rectangle aligns with the remote mount waveguide openings and
the antenna. Ensure that the flange gaskets are properly seated for
weatherproof operation. If an XP type slip-fit antenna is used witha remote mount installation, an optional waveguide adapter must
be ordered from DMC Stratex Networks to change the antenna
feed from an XP type slip-fit connection to a waveguide flange
(frequency band dependent). See Chapter 9, DART Product
Ordering Guide, for details.
NOTE:The remote mount canalso be wall-mountedwith locally procuredfasteners, such as lagbolts. The length andtype of fastener aredependent on the walltype.
NOTE:
See the DART ProductOrdering Guide, Chapter9 of this manual, orconsult your local DMCStratex Networksrepresentative for detailsabout remote mountingkits, antennarequirements, andflexible waveguide forconnecting the ODU tothe antenna remotely.
8/10/2019 Dart DMC
27/161
DART User Manual Install DARTpg. 19
850-900203-001, Rev. D
PowerDissipation
Table
E. Use the latching mechanism provided to attach the ODU to theremote mount. The arrow on the label attached to the ODUs
baseplate indicates polarization.
Step 3. Adjust the ODU/antenna assembly to the desired location on the pole
and place the antenna and ODU in approximate desired azimuth(horizontal angle) and elevation for coarse alignment of the path.
Connect the ODU cable
The ODU cable ordered separately from DMC Stratex Networks comes in a variety
of options, including cables pre-terminated with a Mil-type connector at one or both
ends.
See Chapter 9, DART Product Ordering Guideto order cables, connectors, or
custom termination devices, such as the Deluxe or Standard CTU.
Step 1. Measure the ODU cable to length. First measure approximate distancebetween the ODU mount and the terminal block, punch block or
optional DMC Stratex termination device that the other end of the cable
connects to. Then allow (add) these extra lengths:
12 to 16 inches (30.48 to 40.64 cm) for a drip-loop at the ODU.
at least 4 extra inches (10.16cm) per end for termination of the cable.
slightly more extra cable if this is your first time terminating a cable justin case a mistake is made.
See below for recommended maximum cable lengths.
Power
Level
Custom Cable
(low loss)
Standard Cable (six and
eight pair Belden type)+/- 24 VDC 200 feet (60 meters) 30 feet (9 meters)
+/- 48 VDC 300 feet (90 meters) 150 feet (45 meters)
+/- 60 VDC 300 feet (90 meters) 200 feet (60 meters)
Power dissipation can be budgeted for the DART ODU, CTU, and the
cable, and cable lengths extended beyond the recommended maximum
(300 feet) as long as the voltage remains within the ODU limits
(+/- 24 to +/- 60 VDC). Refer to the following power dissipation table for
each cable type (Standard or Custom) to select the proper cable length
and power requirements for the DART terminal.
100 ft (30 m) 200 ft (60 m) 300 ft (90 m) 500 ft (150 m)Nominal InputVoltage
Std. Custom Std. Custom Std. Custom Std. Custom
+/- 24 VDC 38 W 33 W N/A 38 W N/A N/A N/A N/A
+/- 48 VDC 34 W 31 W 38 W 32 W 56 W 34 W N/A 40 W
+/- 60 VDC 32 W 30 W 34 W 31 W 37 W 33 W N/A 37 W
RecommendedMaximum Cable
Lengths
8/10/2019 Dart DMC
28/161
DMC Stratex Networks
pg. 20 Install DART DART User Manual
Step 2. Terminate the ODU end of the cable with a Mil-style femaleconnector. To do this, follow the instructions in,Cable Assembly
Procedure - Detailed Instructions, page 34.Do NOT hook the cable
into the ODU at this point.
Step 2A. If you are installing a Deluxe CTU or a CTS, terminate the other(indoor) end of the ODU cable with a Mil-style male connector. See
Cable Assembly Procedure - Detailed Instructions,page 34 for
instructions.
Step 3. Connect the indoor end of the ODU cable to a terminal block, punchblock or one of the following three custom termination devices from
DMC Stratex Networks.
Deluxe CTU(Cable Termination Unit), page 23.
Standard CTU, page 26.
CTS(Cable Termination Strip), 32.
If youre hooking to a DMC device, turn to one of the pages listed above forinstallation instructions.
Step 4. Connect the terminal block, punch block or optional DMC StratexNetworks termination device to a DC Power Converter.
NOTE: For normal operation, the ODU requires an input power range of +/-24 to +/- 60 VDC.
Step 5. Attach the end of the ODU cable terminated with the Mil-style femaleconnector to the ODU.
Step 6. Power up the DART by switching on the DC power converter. Sinceyoull be testing for proper alignment by measuring approximate RSL
(Receive Signal Level), make sure the DART at the other end of the linkis also powered up. It is recommended that you have an assistant
stationed at the other end of the link to help with alignment.
Align the antenna
Step 1. Ensure that the DART transmitter is un-muted. This is the factorydefault, but you can verify through LinkView. See Change theTransmit Power, page 78,for information about turning on the Tx
output power for alignment operations after setting the desiredfrequency (channel).
NOTE:
Skip this step ifyour ODU cableis already pre-terminated at thisend with the
correct "Mil-style"connector.
8/10/2019 Dart DMC
29/161
DART User Manual Install DARTpg. 21
850-900203-001, Rev. D
Step 2. Connect a BNC to banana connector cable attached to a multi-meter(DC voltage, 0-5VDC) to the BNC connector on the ODU faceplate. To
do this, remove the cap from the AGC BNC connector on the ODU.
You will find this cap opposite, not next to, the large ODU cable
connector.
.
ODUFaceplate
Ground Lug(M6)
Ground Lug(1/4-20)
BNO Connector(Used for
LinkView)
PolarizationIndicator
HorizontalPolarization
Vert icalPolarization
ODU Cable Connector(18-pin Male)
BNC Connector(AGC)
The following diagram details the difference between the AGC BNC
connector and the BNO connector. Ensure you are removing the cap from
the AGC BNC connector for antenna alignment operations.
DifferencesBetween BNO
Connectorand
BNC Connector
PIN
SOCKET
BNOConnector
SOCKET
BNCConnector
8/10/2019 Dart DMC
30/161
DMC Stratex Networks
pg. 22 Install DART DART User Manual
Step 3. As you adjust the antenna, use the multimeter readings to achieveaccurate alignment. The AGC voltage corresponds to the RSL, where
the voltage steps 0.1 VDC are equivalent to 1.0 dBm steps. See the
following chart for linearization of AGC voltage and RSL (+/- 3dB
accuracy).
AGC (VDC) 1.0 2.0 3.0 3.5 4.0 4.5 5.0
RSL (dBm) -80 -70 -60 -55 -50 -45 -40
AGC/RSL Accuracy = 3dBm
For maximum efficiency, it may be helpful to be in communication with a
partner stationed at the antenna on the other end of the link.
Replace the cap on the AC BNC connector when you are finished.
NOTE: While the AGC (BNC) connector is in use (cap removed), LinkViewcan only be used via the ODU (BNO) connection. When the BNC connectoris not in use (cap replaced), LinkView can be used via the ODU (BNO)
connection or via the optional CTU/CTS (RS232) connection. (The CTSrequires an RS422 to RS232 converter).
Step 4. Confirm that the AGC reading approximates the expected RSL from thepath calculations.
Step 5. Ensure that the ODU/antenna assembly is secure to the mount and thatall adjustments are properly secured.
Step 6. Secure the multi-pair cable with tie straps. Connect ground betweenODU (either metric or Imperial) and a nearby local ground point using
minimum 9AWG wire (25mm2conductor). Use an ohmmeter to confirm
proper ground.
2.2 Install DART Accessories and OptionsDepending on your needs, DMC Stratex Networks offers the following three
equipment options for terminating the indoor end of the ODU cable.
Deluxe CTU
Standard CTU
CTS (cable termination strip)
Each is described below, starting with the most feature laden and ending with the
most basic.
Linearization ofAGC Voltage
and RSL
8/10/2019 Dart DMC
31/161
DART User Manual Install DARTpg. 23
850-900203-001, Rev. D
Deluxe CTUBesides providing convenient termination of the ODU cable indoors, the Deluxe
CTU provides additional functionality, such as the ability to monitor traffic
during maintenance without interruption. It can be used at one or both ends of a
link, depending on functional requirements. If the Deluxe CTU functionality is
only required at one end of a link, then the Standard CTU (DS-1 or E1), the CTS,or a terminal or punch block can be used at the other end of the link to terminate
the ODU cable.
Install the Optional Deluxe Cable Termination Unit (CTU)
The Deluxe CTU is available as a balanced DS-1 or E1 (RJ-45 connector)
and as an unbalanced E1 (dual BNC connectors).
Deluxe CTU:BalancedE1/DS-1Back Panel
DeluxeCTU
ModemShelf Assembly
The optional Deluxe CTU and modem shelf require only 1 rack unit of
vertical 19" rack space. The Deluxe CTU uses an 18-pin connector similarto the DART ODU connector. The only difference is that the pins which
terminate the conductor into the connector are male pins, whereas the
connector at the ODU end uses female sockets.
The following equipment is included with the Deluxe CTU.
18-pin male connector
DC power connector (Phoenix type-3 pin) Alarm relay connector (Phoenix type-2 pin)
5 (Five) 3.15A Slo-Blow fuses
Shelf for CTU/modem mounting in 19" rack, 1 Rack unit high (including3 attachment screws)
5 (Five) standard rack mounting screws
NOTE:Shielded cables andconnectors for allinterfaces are highlyrecommended tocontrol EMC
/EMI/ESD andsusceptibility torequired levels forCE and FCC partpart 15 compliance.
8/10/2019 Dart DMC
32/161
DMC Stratex Networks
pg. 24 Install DART DART User Manual
Step 1. Terminate the end of the ODU cable that hooks to the Deluxe CTU witha Mil-style male connector. For step by step instructions, see CableAssembly Procedure - Detailed Instructions, page 34.
Step 2. The CTU requires 24 to 60 VDC power. Wire the 3-pin powerconnector with the required input voltage as shown in the following
diagram, with wire ends stripped back by 3mm and secured inside eachslot. Use a small flat-blade screwdriver to tighten securely (tinned wires
are recommended).
3-Pin PowerConnector
for optionaldeluxe
cable termination unit ReturnNo
Connect+-24 to 60 VDC+-
Step 3. Prior to installing the CTU, configure Port 2 for Ethernet, RS232, or
RS422 by removing the CTU cover and setting jumper wires as shownin the following diagram.
CTU InternalBoard
Rear View
Step 4. Configure jumpers to receive signals from the cable that connectsLinkView to the DART. This will be either a straight (thru) cable or a
null modem cable. A null modem cable is a result of all conductors
wired in the mirror image of a straight thru RS232 or RS422. When
finished, verify that all screws are secured on the CTU cover beforeinstalling into the equipment rack.
DetailDrawingJumpers for
LinkView cablesJP1B
JP1A
JP1B
JP1A
LinkView DB-9Straight (Thru) cable
LinkView DB-9Null Modem cable
WARNING:Exercise proper ESD grounding(environmental and personal)precautions at all times whenaccessing CTU/CTS internalconnectors and jumpers and ODUcable connectors.
8/10/2019 Dart DMC
33/161
DART User Manual Install DARTpg. 25
850-900203-001, Rev. D
Step 5. Install the CTU and shelf into the equipment rack, to a wall, or to adesktop. Secure using 4 No. 12 Phillips dome-head screws provided in
the installation kit (or suitable fasteners for specific installation) for rack
installations.
Step 6. Use minimum 14-gauge (1.5mm2
conductor) wire and suitable groundlugs to terminate ground between the CTU ground post and nearby
grounding point. Verify ground continuity with an ohmmeter.
Step 7. Set the LED/Relayswitch on the front panel of the CTU to LEDforlocal display of an alarm condition, or install alarm relay connection and
set switch to Relay. The Relay connection is a Normally Open (NO)form C (2-pin phoenix connector) dry contact type relay that is
activated by an alarm.
Step 8. Install tributary data cable(s) to the TRIB port(s) on the CTU. Use100/120-ohm RJ45 compatible cable and shielded connectors for
balanced systems.
Pin # Signal1 Rx Data (-)
2 Rx Data (+)
3 Rx Ground
4 Tx Data (-)
5 Tx Data (+)
6 NC
7 NC
8 Tx Ground
Step 9. If the SNMP NMI option is installed, Port 1 and Port 2 can provideRS232 and RS422 connections for SLIP/PPP connections. Port 2 also
supports other net connections for NMS connection. Port 1 is also usedfor LinkView. Refer to Chapter 6, Configure DART, for configurationdetails.
Port 1 LinkView/SLIP/PPP
RS232 DB-9 (Female)Connector on CTU
PIN 9
PIN 5 PIN 1
PIN 6
See below for Port 2 connection details
RJ45Tributary
Connector forBalancedRadios
PIN 1 PIN 8
8/10/2019 Dart DMC
34/161
DMC Stratex Networks
pg. 26 Install DART DART User Manual
Port 2Ethernet/SLIP/PPPRS232/RS422 RJ45(Female) Connector
on CTU
Pin # ETHERNET RS232SLIP/PPP
RS422SLIP/PPP
1 Tx Data (+) NC Tx Data (+)
2 Tx Data (-) Rx Data Tx Data (-)
3 Rx Data (+) Tx Data Rx Data (-)
4 NC NC Rx Data (+)
5 Ground Ground Ground
6 Rx Data (-) NC NC
7 NC NC NC
8 NC NC NC
NOTE:
An optional pre-terminated ODU to Deluxe CTU cable is available. SeeChapter 9, DART Product Ordering Guidefor details, or consult your localDMC Stratex Networks representative.
Standard CTUThe Standard CTU is available in a variety of models. The E1 Standard CTU model
comes in a balanced (RJ-45) or unbalanced (BNC) model. A DS-1 Standard CTU
(RJ-45) is also available. For fractional E1 data applications, a 10Base-T Ethernet
CTU and an E1 CSU/DSU (V.35) model are available. The balanced and unbalanced
E1 models can be used interchangeably on a link (and with a Deluxe CTU/CTS or aterminal block), as the data stream retains its G.703 characteristics. However, the
10Base-T and V.35 models must be used explicitly with a same interface protocol at
the facing end, for example, 10-Base-T to 10Base-T.
Standard CTU Installation Balanced (E1/DS-1),
Unbalanced (E1), and Ethernet CTU 10 Base-TThe Standard CTU requires manual configuration of Port 1 and Port 2 for
the interface protocol (RS232, RS422 or Ethernet for Port 2) and cable type
(Port 1, thru or null) through a series of jumpers on the PCA (Printed Circuit
Assembly). To ensure correct operations and for proper strain relief, the
ODU cable must be properly terminated inside the CTU.
The following equipment is included with each standard CTU.
DC power connector (Phoenix type 3 pin)
Alarm relay connector (Phoenix type 2 pin)
3.15A Slo-Blow fuses 5 Rack mounting screws
Rack mounting U bracket (for dual Standard CTU rack mounting)
Modem shelf (for single CTU rack can be used with a customer suppliedmodem)
Panhead screws (5 each) for securing the ODU strain relief inside theCTU.
NOTE:
Shielded cables andconnectors for allinterfaces are highlyrecommended tocontrol EMC/EMI/ESDand susceptibility torequired levels for CEand FCC part 15compliance.
PIN 1 PIN 8
8/10/2019 Dart DMC
35/161
DART User Manual Install DARTpg. 27
850-900203-001, Rev. D
Tie straps (2) for securing wire pairs to PCBA inside CTU
Copper wire mesh sleeve for EMC/EMI compliance
Terminate the DART Standard CTU to the ODU Cable
The Standard CTU does not use the Military type connector to terminate
the ODU cable. Instead, the ODU cable conductors are terminated directly
to a terminal block on the Standard CTU PCBA, per the following
instructions.
The following installation supplies are included with each standard CTU
Tie straps, 4 inch (2 each) - for securing the conductors/wire pairs insidethe CTU.
Panhead screws (5 each) - for securing the ground lugs and ODU cablestrain relief inside the CTU.
Wire mesh sleeve, copper.
Required Tools to be supplied by the Customer
Wire strippers, 24 AWG and 16 AWG (16 AWG strippers only requiredif a custom ODU cable is used).
Heat gun for activating the temperature sensitive heat shrink.
Soldering iron for tinning of conductor tips.
DVM/Ohmmeter for performing continuity check to confirm that eachpair conform to proper location on the opposite end of the cable (at
ODU).
StandardE1 Unbalanced,
E1/DS-1 Balanced,and
Ethernet 10 Base-T
CTU
CA P , CA B LERELIEF, CTU, XP2
DMC P/N 220-000414-001
SCREW, SEMS 2-40x3/8P A N HE A D P HILLIP S
DMC P/N 240-000189-212
CT UA S S E M B LY
B OTTOMV IE W
OD UCONNE CTOR
W IRE M E S H S LE E V E ,COP P E R
DMC P/N 240-000256-001
CTU P CB AA S S E M B LY
B OTTOMV IE W
Step 1. Loosen the four (4) captive screws on the CTU front panel. Remove theStandard CTU PCBA and front panel from the CTU enclosure by gently
8/10/2019 Dart DMC
36/161
DMC Stratex Networks
pg. 28 Install DART DART User Manual
pulling the two items apart. Examine the underside (non-component
side) of the PCBA to see how the cable will be terminated and secured.
Inventory the parts in the CTU kit per the previous lists.
Step 2. Measure 5 inches (13 cm) from the cable end to be terminated. Mark therecommended length on the ODU cable and remove the outer insulation
without nicking or cutting the wire-braided shield underneath.
Step 3. Insert the cable into the cable penetration in the front panel of the CTUby first removing the strain relief strap screws and the strap itself on the
backside of the CTU front panel. Then, slide the cable through the hole
provided in the Standard CTU faceplate. Slide the cable far enough
through the penetration to ensure that the end of the cable, including the
wire-braided shield and drain wires, are completely inside the CTU. (A
piece of tape over the braided shield at the cable end may speed
insertion into the CTU).
Step 4. Trim the wire-braided shield to 1-inch (2.5 cm) beyond the outer
insulation and pull it back against the outer insulation.
Step 5. Take the six (6) or eight (8) conductors (depending upon ODU cabletype used) and remove the foil from each pair, taking care not to untwist
the pairs and confuse the wires. It is recommended that a piece of
electrical tape be used to retain the pairs. Separate the drain wires
(exposed ground wires associated with each pair) from the twisted pairs
and pull back against the wire-braided shield. Cut the twisted drain
wires to 1 inch (2.5 cm), the same length as the wire-braided shield.
Step 6. Use a twisting motion to slip the wire mesh sleeve over the conductorsdown to the wire-braided shield and drain wires. Carefully continue to
slip the wire mesh sleeve over the wire-braided shield and drain wires to
the edge of the outer insulation. Be sure not to slip the sleeve more than
1 inch (2.5 cm), or beyond the pulled back shield and drain wires.
See illustration on next page.
NOTE:
Be sure todiscardall cut wiresand braids toensure none goinside the CTU.
8/10/2019 Dart DMC
37/161
DART User Manual Install DARTpg. 29
850-900203-001, Rev. D
Step 7. Pull the cable back through the CTU hole so that the wire mesh sleeve isup against the nylon insulation bushing and on top of the cable strainrelief mount. Secure the strain relief to its mount and tighten screws to
ensure that any tugging on the cable will not allow it to be pulled loose
of the strain relief of the CTU.
Step 8. Route wire pairs to the proper location on the terminal strip on the CTUPCBA (J8 to J11, Pins 1 to 4). If the wire pairs were allowed to be
separated, it is recommended that you use an Ohmmeter to confirm each
conductors path/location before terminating the wire. Taking care to
leave enough slack in the wires for securing the pairs to the PCBA with
the tie straps, cut each conductor to length. Strip each conductor .25
inches (.75 cm). It is recommended that you tin each exposed conductor
to protect against the wires unraveling.
O D U C A B L E C O N D U C T O RST R AIN R EL IEF ( U SE T IE WR APS) 2X
CA B LE E NTRY P O INT
DART Cable Termination Pinout - Standard CTU
PIN SIGNAL WIRE COLOR (1)WIRE COLOR (2)
J8-1 RX DATA (+) BLUE BLUE
J8-2 RX DATA (-) BLACK BLACK
J8-3 TX DATA + B R O W N B R O W N
J8-4 TX DATA - BLACK BLACK
J9-1 PORT 1 TX DATA + BLACK BLACK
J9-2 PORT 1 TX DATA - RED RED
J9-3 PORT 1 RX DATA + BLACK BLACK
J9-4 PORT 1 RX DATA - W HITE W HITE
J10-1 ALARM A YE L L O W YE L L O W
J10-2 ALARM B BLACK BLACK
J10-3 PORT 2 TX DATA + BLACK N/A
J10-4 PORT 2 TX DATA + O R AN G E N/A
J11-1 PORT 2 RX DATA + BLACK N/A
J11-2 PORT 2 RX DATA - G REEN N/A
J11-3 PO W ER B W HIT E BL ACK
J11-4 PO W ER A R ED G R EEN
(1) 8 twisted pair cable - per Belden 8168 color code
(2) 6 twisted pair cable - per Belden 8166 color code
NOTE.Be sure that thewire mesh sleeveis still over thebraid and drainwires and has notbeen jostled fromits proper positionwhile pulling backthe cable. Also,verify that the braidand drain wires arenot touching anyelectrical
component or partof the PCBA insidethe CTU.
8/10/2019 Dart DMC
38/161
DMC Stratex Networks
pg. 30 Install DART DART User Manual
Step 9. After properly terminating the six (6) or eight (8) pairs of wires per thewire chart, separate the pairs into equal bundles and secure to the CTU
PCBA using the supplied tie straps and the three (3) pre-drilled holes in
the PCBA. Remove any excess from the tie straps and discard.
Step 10 Ensure that no loose wires or cut ends are touching the PCBA. It isrecommended that the board be blown with air to free all wire ends.
Step 11. Replace the CTU PCBA and attached ODU Cable into the CTU coverassembly. Take care to ensure that the PCBA is sliding between the
slots in the cover assembly sides for proper mechanical fit. Secure the
four (4) captive screws on the front panel to properly close the CTU.
Step 12. Secure the CTU to a rack (singe or double rack mountingconfiguration), to a wall using the movable mounting ears (use proper
fasteners such as concrete/drywall fasteners, or wood screws), or mount
on a desktop. Provide proper grounding to the ground lug on the front
panel for correct operation.
DoubleCTU
Assembly(Unbalanced E1)
240-000177-206 (6X)
240-000232-003 (6X)
220-000324-001 (2X)
240-000189-206 (6X)
220-000415-001
Modem ShelfAssembly
(Balanced DS-1/E1)
220-000445-001
220-000324-001
240-000189-206 (6X)
8/10/2019 Dart DMC
39/161
DART User Manual Install DARTpg. 31
850-900203-001, Rev. D
Step 13. Configure Port 1 and Port 2 for LinkView and SNMP. Refer to thefollowing diagram for configuration details for Port 1 and Port 2 for
LinkView and SNMP.
CTU InternalBoard:
TOP
ConnectorDetails:Standard
CTUs
8/10/2019 Dart DMC
40/161
DMC Stratex Networks
pg. 32 Install DART DART User Manual
CTS (Cable Termination Strip)
When the features of the Deluxe or Standard CTUs are not required or when size
is a challenge, the CTS provides a compact solution for termination of the ODUcable. The CTS is a simple cable termination strip enclosed in a compact metallic
enclosure that fits in the palm of your hand. This small size allows it to bemounted virtually anywhere. The CTS provides the same general user
connections as a CTU, but in a more compact manner. All management ports are
available, as well as both balanced and unbalanced tributary connections on thesame model. However, Port 1 is only available as an RS422 connection. An
optional RS232 to RS422 cable must be ordered if a PC is to be connected to Port
1 for LinkView operations through the CTS.
CTS
Cable TerminationStrip
CTS Mounting Bracket Orientation Options
The left mounting ear can be rotated 360 degrees (in 90 degree increments)
to mount in the desired position in a rack or to a wall.
Mounting earcan be rotated
Install the CTS
Step 1. Terminate the ODU cable at the CTS end with a Mil-style maleconnector. For instructions, see Cable Assembly Procedure -detailed instructions, page 34.
8/10/2019 Dart DMC
41/161
DART User Manual Install DARTpg. 33
850-900203-001, Rev. D
Step 2. Attach the end of the ODU cable terminated with the Mil-style maleconnector to the CTS and properly mount and ground the CTS.
Step 3. Configure CTS Port 2 for the desired operation (if SNMP is used) andthe E1 balanced/unbalanced jumpers (E1 only, DS-1 is always
balanced). The shunts (jumpers) are accessible through the rear panel of
the CTS.
The Data and Port 2 conf igurat ion jumpers are located at therear of the CTS, accessible via the metal acce ss panel .
B A L A N C E D
R S 4 2 2U N B A L A N C E D
E T H E R N E T
Data Conf igurat ion(Unbalanced or Balanced)
Port 2 Conf igurat ion(Ethernet or RS422)
8/10/2019 Dart DMC
42/161
DMC Stratex Networks
pg. 34 Install DART DART User Manual
2.3 Cable Assembly Procedure - DetailedInstructionsIf the DART radio youre installing is equipped with the NMI (SNMP) moduleoption, a cable with 8 twisted-pairs (Belden 8168 or equivalent) is required.
However, if the ODU is not equipped with the NMI module option, only 6 shielded
twisted-pairs (Belden 8166 or equivalent) are required.
Unless the ODU cable youre working with came pre-terminated, the following
customer-supplied tools are required for assembly:
Connector termination tools
Crimp tool (for both 16 and 24 AWG)
Contact insertion tools (24 and 16 WAG tool, for both Standard and Custom cable
termination)
Contact removal tools (24 and 16 WAG tool, for both Standard and Custom cabletermination)
A Mil-style female connector for terminating the cable at the ODU end is shipped
with each DART ODU.
A Mil-style male connector for terminating the cable at the indoor end is shipped
with each Deluxe CTU (cable termination unit) or CTS (Cable Termination Strip)
available as an option from DMC Stratex Networks.
Except for flip-flopped pin locations, the procedure is identical for terminating the
cable with either connector. Step 6 of this section contains pinout diagrams for eachconnector.
NOTE: You do not need a connector on the indoor end of the ODU cable ifyoure hooking to the Standard CTU (Cable Termination Unit) also availableas an option from DMC Stratex Networks. Instead, the ODU cableconductors are terminated directly to a terminal block on the Standard CTUcircuit board. For details, see Standard CTU Installation, page 26.
See below for step by step instructions on terminating the ODU cable with Mil-
style connectors.
Step 1. The Female Connector Kit that ships with each DART ODU and theMale Connector Kit that ships with each Deluxe CTU or CTS contain
the items listed below.
Connector
Backshell
Coupler Nut Assembly
Sockets (Female Kit) / Pins (Male Kit)
8/10/2019 Dart DMC
43/161
DART User Manual Install DARTpg. 35
850-900203-001, Rev. D
Tie Strap
Compare against the drawing below to verify that you have all of these items.
Mil-style
ConnectorKit items
HEAT SHRINK TUBING
TI E STRAP
SMALL PIN , 16 PER CONNECTOR
LARGE PIN 2 PER CONNECTOR (FOR CUSTOM CABLEP O W E R L E A D S , 1 6 A W G
In Male Kit
C O N N E C T O RBACKSHELL
COUPLER NUT
A S S E M B L Y
SMALL SOCKET, 16 PER CONNECTOR
LARGE SOCKET 2 PER CONNECTOR (FOR CUSTOM CABLEPOWER LEADS, 16 AWG
In Female Kit
Step 2. Temporarily remove the O-ring from inside the backshell. Remove anddiscard the serrated ring behind it. Replace the rubber o-ring.
Step 3 Measure the cable to length. Allow an additional 12 to 16 inches (30.48to 40.64 cm) for a drip-loop at the ODU. Allow at least 4 extra inches
(10.16cm) per end for termination of the cable. Allow slightly more
extra cable if this is your first time terminating a cable just in case a
mistake is made. Using the backshell as a guide, strip the cable outer
sheath approximately 1.83" or 46.81mm. Avoid damaging the braided
wire shield.
8/10/2019 Dart DMC
44/161
DMC Stratex Networks
pg. 36 Install DART DART User Manual
Step 4. Fold back the braided shell from the cable. Slide the heat shrink tubingover the cable end. Slide the backshell over the cable end, making it
even with the end of the braided shield. Do not allow the backshell to
slip beyond the braided shield. Temporarily secure the backshell in
position with tape.
HEAT SHRINK
BACKSHELL
Step 5. Trim back the foil from the conductor pairs. Do not remove the drainwires. If the SNMP option is not installed and the six-pair cable is used,there will be fewer wires in the cable to terminate into the 18-pin
connector (12 wires versus 18 wires).
Strip back the conductor insulation on each wire approximately .200" or
5.15mm (See the following detail drawing). Set crimping tool to setting 22
and crimp large terminals on red/black pair. Set crimping tool to setting 24
and crimp small terminals on remaining wire pairs. Divide drain wires into
two groups and crimp with two small terminals.
Step 6. Install the coupler nut over the connector insert. Make sure the couplernut is oriented correctly. Stuff the connector terminals into the
connector. Insert with the insertion tool working by rows across the
connector.
Refer to the drawing on the next page for specific pinout for the female
connector on the ODU end. Pinout instructions for the male connector on
the indoor end follow immediately after.
8/10/2019 Dart DMC
45/161
DART User Manual Install DARTpg. 37
850-900203-001, Rev. D
Pin connections for female connector on ODU end
RUB B E R
S E A L
L A
G EF
INFORM A TION
RE FE R TO THE
FOLLOW ING
DRA W ING FOR
S OCK E T INS E RTION
F
A
B
C
D
E G
H
J
K
LMN
P
R S
T
U
See the ODU Cable Connection Pinout Table below.
PIN SIGNAL WIRE COLOR (1) WIRE COLOR (2)A RX DATA (+) BLUE BLUE
L RX DATA (-) BLACK BLACK
B ALARM RELAY A YELLOW YELLOW
N ALARM RELAY B BLACK BLACK
C PORT 2 TX (-) ORANGE N/A
D PORT 2 TX (+) BLACK N/A
E PORT 2 RX (-) GREEN N/A
R PORT 2 RX (+) BLACK N/A
H PORT 1 TX (-) RED RED
J PORT 1 TX (+) BLACK BLACK
K TX DATA (+) BROWN BROWN
M TX DATA (-) BLACK BLACK
P POWER IN A RED GREENT POWER IN B WHITE BLACK
S PORT 1 RX (-) WHITE WHITE
G PORT 1 RX (+) BLACK BLACK
F DRAIN WIRE DRAIN WIRE DRAIN WIRE
U DRAIN WIRE DRAIN WIRE DRAIN WIRE
8 twisted pair cable per Belden 8168 color code
6 twisted pair cable per Belden 8166 color code
ODU CABLEConnection
Pinout
8/10/2019 Dart DMC
46/161
DMC Stratex Networks
pg. 38 Install DART DART User Manual
Pin connection for male connector on inside end
Use this connector if youre hooking to a Deluxe CTU or a CTS from DMC
Stratex Networks.
R U BBER
SEAL
B
C
D
EF
G
H
J
K
M N
P
RS
T
ALU
DETAIL A
REFER TO THEENLARGEDD R A W I N G
B E L O W F O RPIN
INSERTIONINFORMATION
A L
E F G
See Cable Connection Pinout Table above (previous page)
Step 7. After confirming that the pinout is correct, remove the tape, thread thebackshell into the connector, insert and tighten. Fold the braided shield
over the end of the backshell. Secure the braid to the backshell with a tie
strap. Trim any excess tie strap and braided shield. Position the heat
shrink halfway over the backshell. Heat the heat shrink with a suitable
heat gun. Be careful not to overheat the connector. Vapor wrap or
electrical tape can be wrapped around the connector and heat shrink tube
to add an additional vapor barrier over the heat shrink.
TI ES TRA P
BRAIDED SHIELD
HEAT SHRINK
HEAT SHRINK
8/10/2019 Dart DMC
47/161
DART User Manual Install DARTpg. 39
850-900203-001, Rev. D
Step 8. Verify continuity by measuring end-to-end resistance on each pin andwire with an ohmmeter.
Warning:
Do not use the Ohmmeter to check cable continuity if one end of the cable isalready hooked to either the ODU, a CTU, or any other customer equipment.Damage to sensitive circuitry may be caused from the voltage/current presented
by the Ohmmeter.
If a short or open circuit occurs during testing, check the wire connection
and repeat measurement. Residual resistance from the cable should be seen
on nominal cable lengths.
8/10/2019 Dart DMC
48/161
DMC Stratex Networks
pg. 40 Install DART DART User Manual
This page intentionally left blank.
8/10/2019 Dart DMC
49/161
DART User Manual Load LinkView Software & Connect to DART41
850-900203-001, Rev. D
3. Load LinkView Software& Connect to DART
Sections
3.1 Configuration requirements pg.41
3.2 Install LinkView on a PC pg.41
3.3 Connect LinkView to DART via Cable pg.45
3.4 Connect LinkView to DART via Modem pg. 47
3.1 Configuration requirementsLinkView is the DMC Stratex Networks radio softwar