DataNet - ltm.as fileDataNet Solution. WIRELESS INTELLIGENT LOGGING NETWORK. The DataNet solution...

Post on 24-Apr-2019

220 views 0 download

transcript

DataN

etSolution

WIRELE

SSINTELL

IGENTLOGGIN

GN

ETWORK

www.fo

urtec.co

m

DataNetisanessentialhardwareandsoftwaresolutionthatcan

empoweranyorganizationtomonitortheirenvironmentusingthe

ZigBeewirelessnetwork.

TheDataNetcomprehensivereal-timedataloggingsolutionis

directedbyevent-drivensecuritypolicies.DataNetdeliversatruly

worthydataloggingsolutionbyleveragingthepowerofZigBee

wireless,2.4GHztelemetryprotocol.Supportingupto65,000units

pernetwork,withfast,cable-freeinstallationforinstantsetup.

• Wirelessdataloggingforprocessing,transportationandstorage

• MultiplenetworkmanagementfromsingleworkstationorviaLANforlong rangemonitoring

• Internalsensorsforsite-specifichumidity/temperaturemonitoring

• Multiplemodelsmeasuring4to20mA,0to1V,PulseCounter,PT1002-wires, NTC,ThermocoupleJ,KandT,Contactinputs

• Fullyreliablereal-timewirelessmonitoringnetwork

• MultiplealarmsviaSMS,emailandexternalsiren

• Worldwidelicense-free2.4GHzband

• OperatingkeypadandLCDdisplay

• APIforintegratingDataNethardwarewithproprietarysystems

Wireless,multi-unitdataacquisition,delivering24/7real-timemonitoringforindustrialenvironments

WAREHOUSINGChemical,industrialandperishablesstorage

PHARMACEUTICALMonitoringenvironmentsinlabs,fridges,freezersandculturerooms

COLDSTORAGEOptimizingtemperatureinrefrigeratedwarehousing

HOSPITALSMedicalalertmonitoring,sterilization,bloodproductsstorageandtransport

COLDCHAINEnsuringqualityproductsthroughoutthecoldchainprocess

DataN

etSolution

WIR

ELESSINTELLIG

ENTLOGGIN

GN

ETWORK

The DataNet solution comprises a range of loggers measuring a variety of inputs, including internal temperature and humidity sensors. From 5-6 input models down to the more cost-effective single or dual input Mini DataNet models, we offer a comprehensive solution for every application.

TheDataNetmulti-unitdataacquisitionsolutionisgeared

towards24/7real-timedataloggingformissioncritical

organizations.TheDataNet’scomprehensiveonline

solutionisdirectedbyevent-drivensecuritypolicies.

Loggingunitsfunctioninawirelessmeshnetwork

configuration,allowingfor65,000unitsineachnetwork.

Thisenablesreal-timemonitoringofmultipletestpoints

inasingleoperation.

TheDataNetproductfamilysupportsonboard

temperatureandhumiditysensors,aswellasthe

followingindustrystandardinputs:4externalchannelsfor

4to20mA,0to50mV,0to1V,PT-100,Thermocouple,

Contact,PulseCounterandFrequency.

DataNetsystemoffersabroadselectionofloggermodels

meetingawidevarietyofindustryapplicationsneeds.

LCDScreen

MenuButton

Scroll/OnButton

MiniUSBConnector

ACSocket

DataLoggerExternalInputs(4)

Internalsensorhousing

12VExcitation

• DNR900 Receiver/Repeater –theheartofthesystemcontrolsandcollectsthe

datafromtheendunits.Alsosuitableforextendingthesystemrange.

• DNL910 and DNL920 –loggerswithinternaltemperatureand/orhumidity.

Supportsfourexternalinputs:4to20mA,0to1V,0to50mV,PT-1002wires,

Thermocouples(J,KandT),Contact,PulseCounterandFrequency

• DNL910 PA and DNL920 PA –loggerswithintegratedpoweramplifierfor

extendedrange.SamesupportedexternalandinternalsensorsasDNL910and

DNL920.

• DNR800 Mini Repeater –cost-effectiveunitforextendingthesystemrange.

• DNL804-BXT, DNL808-BXT, DNL810-BXT –cost-effectiveloggerssupporting

uptotwoinputs,measuringtemperature,humidityandcurrent(4-20mA).

IncludesuptofourAA3.6Vfor3-yearbatterylife.

DNL920 DNL910

DNL920PA

DNL910PA

DNR900Receiver

DNR800DNR900

DNL808-BXT

DNL804-BXT

DNL810-BXT

Data View Features

Real-timedatainmultipledisplays(Graph,Table,Statistics)

Sensor View

Real-timesensor-specificdataviewwithalarmstatus

Map View

• Internationaldateformat• Abilitytorenameeverylogger andexternalinput• MapViewdisplayingunit location,signalpathandsignal strengthtothePC

Alarm Features

Alarmlevelsetupwithemail&SMSnotifications.Fouralarmlevels,allowingforprogrammingofseparateparameters,includingalarmdelayandduration

DataSuiteSoftwareforDataNetSupported Operating Systems:Windows®XPSP3/Vista/7(32and64Bit)

Minimum Hardware Requirements:Pentium4,2GHzProcessororbetter,512MBRAM,250MBavailablediskspace

FDATitle21CFRPart11Compliant

The DataSuite Software provides security for your products with online monitoring and control of

multiple networks supporting the entire intelligent DataNet data logging solution via LAN.

DatPass

DatPassisauseradministrationsoftwarewhichsupportstheassignmentofpasswordsandoperatingprivilegesforallfourtecindustryapplicationsoftwareensuringCFRcompliancy.CFRisaFoodandDrugAdministration(FDA)issuedregulation(Title21CodeofFederalRegulations,Part11).

DatPass Audit Trail

ReportModule

TheReportmoduleprovidestheDataSuiteuserwithanintuitiveinterfaceforcreatingandgeneratingreportswhichhavemanyparametersgarneredfromtheDataNetunitsandsoftware.Eachreportcanbeemailedtoaselecteddistributionlist,atpre-definedtimeintervals,inPDFandExcelformat

Analysis Features

Dewpointanalysis,FOPasteurization,histogram,MKT,statisticswithexporttoExcelandCSVformats

Application Example – Medical Center

Receiver

Repeater

CONTROL CENTER

INPUT TYPES

DNL910, DNL920, DNL910-PA, DNL920-PA

4 to 20 mA• Range: 4to20mA• Resolution: 4.76μA• Accuracy: ±0.5%• Loopimpedance: 21Ω

0 to 50 mV• Range: 0to50mV• Resolution: 3μV• Accuracy: ±0.5%• Inputimpedance: 25MΩ• Maximumvoltage: 3.2V

0 to 1 V• Range: 0to1V• Resolution: 200μV• Accuracy: ±0.5%• Inputimpedance: 25MΩ• Maximumvoltage: 3.2V

Temperature PT-100 (2-wires)• Range:-200to400˚C• Resolution:0.1˚C• Accuracy: -200to-60˚C ±0.5% 60to400˚C ±0.5% -60to60˚C ±0.3˚C

Temperature Thermocouple J• Range: -200to1,000˚C• Resolution: 0.1˚C• Accuracy: -200to-60˚C ±0.5% 60to1,000˚C ±0.5% -60to60˚C ±0.5˚C• Coldjunctioncompensationerror: ±0.3˚C

Temperature Thermocouple K• Range: -200to1,000ºC• Resolution: 0.1˚C• Accuracy: -200to-60˚C ±0.5% 60to1,000˚C ±0.5% -60to60˚C ±0.5˚C• Coldjunctioncompensationerror: ±0.3˚C

Temperature Thermocouple T• Range: -200to400˚C• Resolution: 0.1˚C• Accuracy: -200to-60˚C ±0.5% 60to400˚C ±0.5% -60to60˚C ±0.5˚C• Coldjunctioncompensationerror: ±0.3˚C

Contact (for Switch/Door Position)• Range: Open/Closed

Pulse Counter (input 4 only)• Optocouplerinput• Range: 1to65,536counts• Resolution: 1count• Frequencyrange: 0to4,000Hz• Inputsignal: 0to5V• Inputimpedance: 470Ω

Frequency (input 4 only)• Optocouplerinput• Range: 20Hzto4KHz• Inputsignal: 0to5V• Inputimpedance: 470Ω

Internal Temperature• Type: DNL910:PT-100 DNL920:Digital• Range: -20to50˚C• Resolution: 0.1˚C• Accuracy: DNL910:±0.3˚C DNL920:±0.5˚C

Internal Humidity (for DNL920)• Range: 5to95%• Resolution: 0.5%• Accuracy: ±3%at10to90% ±5%at5to10%and90to95%

DNL804-BXT, DNL808-BXT and DNL810-BXT

DNL804-BXT External Current Sensor• Range: 4to20mA• Resolution: 0.06°C1.16uA• Accuracy: 0.5%• Loopimpedance: 21Ω

DNL808-BXT External Temperature Sensor• Range: -50to150°C• Resolution: 0.06°C• Accuracy: -50to60˚C ±0.3˚C 60to150˚C ±0.5%

DNL810-BXT Internal RH/Temperature Sensors• Temprange: -20to50°C• Tempresolution: 0.04°C• Tempaccuracy: ±0.4°C• Humidityrange: 5to95%• Humidityresolution: 0.5%• Humidityaccuracy: ±3%

OUTPUTS

DNR900, DNL910, DNL920, DNL910-PA, DNL920-PA

External Power Excitation (transducers usage)• 12VDC@2A• Resetfuseoverload

Dry Contact Alarm Output• Opencollector• Closepositionresistance:50Ω• Max.Load:50mA,3VDC

DATANET LOGGER SAMPLING FEATURES

• Memorycapacity: ~59,000samples• Samplingrate: Onceeverysecondtoonce every18hours• Samplingresolution: 16-bit• Channelseparation: 80dB

DATANET RF NETWORK COMMUNICATION

• Frequency:2.4GHz• Unitspernetwork:65,000• Datarate:250Kbps• Fullmeshnetworkarchitecturesupported• 128-bitnetworksecurityencryption• Worldwidelicense-free• RFTransmission: DNL8xxandDNL9xx: 4dbm DNR900,DNL9xx-PA: 17dbm DNR800: 20dbm

DATANET HARDWARE SPECIFICATIONS

DNR900, DNL910, DNL920 and DNL9XX-PA

Display• 2-rowLCD• 16characterdisplay

Power Supply• Internalrechargeable4.8VNiMHbattery• Built-inbatterycharger• External12VDCinput

Operating Temperature Range• -20to50˚Cforallmodels• Wateranddustproof:IP54

DNR900 PC Communication• USB2.0compliance• MiniUSBtypeBcable

Casing• PlasticABSbox• Dimensions: 97x93x27mm• Weight: 200gr• Tableandwallmounting

DNL804-BXT, DNL808-BXT, DNL810-BXT

Power Supply• Removablebatterypacksupportingupto4xAA3.6V lithiumbatteries• Batterylife:Upto3yearsdependingonsamplingrate

Casing

Dimensions• DNL810-BXT:10.2x8.8x5.3cm(withouttheexternal antenna)• DNL804-BXTandDNL808-BXT:9x8.8x5.3cm (withouttheexternalantennaandstrainreliefadd-on)

Weight:• 137gnotincludingbatteries• 218gincludingfourbatteries• ExternalAntenna: 17.5g• Wallmounting

Operating Temperature Range• -30to75˚Cforallmodels(operatingattemperature closetoorbelowzeromayaffectbatterylife)• Wateranddustproof:IP54

GENERAL SPECIFICATIONS

Man Machine Interface• 2-buttonkeypad

Standards Compliance• CE,FCC,ICCanada• QuadBand:GSM-850/EGSM-900/ DCS-1800PCS-1900MHz• SupportsOpenAT®softwareplatform• InternalExpansionSocket(AES)interface• RS232SerialInterface• 12VDCexternalpowersupply

DATASUITE SOFTWARE FOR DATANET

• Windows®basedsoftware• Datadisplayedinnumericorgraphicaldisplayofall inputs• Onlineretrievalanddisplayofthecollecteddatain real-time• Definitionofcustomsensors• Fullloggercalibration• Documentationandfiling• OfflineReceiveralarmindication• Alarmlevelsongraphs• Exporttospreadsheets• Analyticalfunctions,forprofessionalanalysisofthe collecteddata• Manualbackupofcalibrationsettings• Over-the-airfirmwareupdate• Softwareintegrationwithrangeoffourtecdata loggers

SpecificationsLengthandTemperaturespecificationsareprovidedinMetricandCelsiusunits

©2012fourtec-FourierTechnologiesLtd.Allrightsreserved.fourtec-FourierTechnologiesLtd.logosandallotherfourtecproductorservicenamesareregisteredtrademarkortrademarksoffourtec-FourierTechnologiesLtd.Allotherregisteredtrademarksortrademarksbelongtotheirrespectivecompanies.P/NBK180,Rev6.12

www.fourtec.com//info@fourtec.com

Aboutfourtec

fourtec–FourierTechnologiesLtd.isarecognizedleaderindata-loggingandmonitoringsolutionsforcontrolled

industrialenvironments,suchasfood,pharmaceutical,medical,storageandtransportationindustries.

Oursolutionsenableourcustomerstodeliverhigherqualityproducts,ensureconsumersafety,complywith

regulatoryrequirementsandincreaseprofitability.Innovation,expertiseandacommitmenttoqualityarethe

valuesthatdrivethedevelopmentandproductionofourproducts.

OrderingInformationPart Number (PN) Product Description

DATANET DEVICES

DNR900A Receiver/Repeater + universal power supply

DNL910A Temperature RF logger with 4 external inputs + universal power supply + calibration certificate

DNL910A-PA Temperature RF logger with built-in Power Amplifier & 4 external inputs + universal power supply + calibration certificate

DNL920A Temperature & Humidity RF logger with 4 external inputs + universal power supply + calibration certificate

DNL920A-PA Temperature & Humidity RF logger with built-in Power Amplifier and 4 external inputs + universal power supply + calibration certificate

DNR800A Mini Repeater with extended RF range + universal power supply

DNL804A-BXT 4 to 20 mA RF logger + external antenna + calibration certificate + extended battery pack

DNL808A-BXT External NTC 10KΩ RF logger(-50 to 150 °C) + NTC temperature probe (2.5 m cable) + external antenna + extended battery pack

DNL810A-BXT Temperature and Humidity RF logger + external antenna + extended battery pack

SENSORS

12753 PT-100 (-70 to 400 °C) 2-wire temperature sensor (2.5 m cable)

12752 PT-100 (-70 to 400 °C) 2-wire temperature sensor (4 m cable)

12751 PT-100 (-70 to 400 °C) 2-wire temperature sensor (6 m cable)

50116 PT-100 (-200 to 400 °C) 2-wire temperature sensor (2.5 m cable)

50165 Thermocouple Type K sensor, 500 mm cable with flat pin connector

DT043 Temperature (-40 to 60 C) and Humidity probe (3 m cable)

DT332 Replacement NTC 10KΩ (-50 to 150 °C) temperature probe (2.5 m cable) for DNL808

ACCESSORIES & SOFTWARE

50164 Quad Band GSM Modem (for DataSuite SMS alerts)

13825 External Siren + Strobe for DataSuite alarm notifications

13750 USB over IP Ethernet adapter

13129 Replacement standard external antenna for Mini DataNet units

13416 External 2.5 m antenna with magnet connector

13330 Mini USB communication cable for DNR900 (3 m cable)

11304 Internal battery pack for DNL9XX loggers

13806 AA 3.6 battery for Mini DataNet External Battery Pack

12928 2/3 AA 3.6 V battery for Mini DataNet logger

AD001 Replacement universal 110V/220V power supply

DataSuite-DN DataSuite Installation CD + mini USB 3m cable + single user license

DS-CFR-DN DatPass for DataSuite meeting 21 CFR Part 11 Compliancy. With DataSuite CFR and DatPass software +mini USB 3m cable + user licenses