DSC PowerSeries Neo Integration
The purpose of this application note is to explain how to setup the
DSC PowerSeries Neo integration with a KT-400 or a KT-1-M (or PCB)
using an RS-232 or IP connection.
Minimum Requirements:
Kantech Controller:
o KT-400 rev1 Firmware 1.23 or higher
o KT-1-M or PCB Firmware 1.03 or higher
DSC:
o TL280R or TL2803GR or 3G2080R Firmware 4.10
Verify Firmware at menu [900]-[460]
Connection:
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
2
Neo Configuration:
Using the DSC PowerSeries Neo Keypad: 1. Enable the TL280R,
TL2803GR, 3G2080R settings:
a. [*8]-[installer code]-[382], Use arrows to scroll to [5] >
Alternate Comm ->Y
2. Enable communication:
a. RS-232: [*8]-[installer code]-[851]-[663] > Ensure only bits
1 and 5 are ON
b. IP:
[*8]-[installer code]-[851]-[693] > define the panel IP
address
UDP: [*8]-[installer code]-[851]-[664] > bit 1, 3, 4
TCP: [*8]-[installer code]-[851]-[664] > bit 3
3. Enter Integration Identification Number in EntraPass
a. [*8]-[installer code]-[851]-[651]
Capture all 12 hex values and enter in EntraPass
4. Enter Integration Access Code in EntraPass
a. [*8]-[installer code]-[851]-[652]
Capture all 8 hex values and enter in EntraPass
EntraPass Setup:
If virtual zone is to be used, please program virtual zone. Address
560, option 1, please refer to
PowerSeries Neo programming manual.
Go to the Devices tab and select the Integrated Panel button
a. Click the New button and name the device accordingly
b. In the Connection Type drop down list, select DSC PowerSeries
Neo
connected to controller (Serial or IP) or DSC PowerSeries Neo
connected
to gateway (Serial or IP)
c. In the Panel model drop down list, select the Panel model
d. Click the Configuration button and enter the master code in the
Master code
textbox
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
3
Note: This code will be used for receiving the programming and
updating the alarm panel with the new user codes. The default
Master code in a DSC intrusion panel is 1234.
e. In the Controller selection for pass-through select the
controller is
connected to DSC PowerSeries Neo panel
1. Enter the Integration Identification Number and Integration
Access
Code gathered in the Neo Configuration section
f. Click Ok
g. In the Panel Component tab, select the number of zones,
partitions and users
to be included
h. Click Save
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
4
i. The Configuration Form will reappear. Select the Default Code
and click OK.
Note: The uploading of the intrusion panel may take 2-3 minutes
depending on the programming. During this time, the intrusion panel
will be in programming mode. Once the intrusion panel uploading is
complete, an event called Panel components upload completed will
occur in the message list.
Programming user codes:
To program new user codes or to modify existing ones, go to the
Devices tab and select Integrated Component
a. Within the Integrated component tab, make sure the View
component
hierarchy button is pressed
b. To better manage the components, click the All Components button
and
select Users
c. Select the Corporate gateway that the intrusion panel is
connected to under
the Gateway drop down list
d. From the Panel drop down list, select the previously created
intrusion panel
e. From the Component drop down list, select a user, and name the
user
accordingly
f. Click on Click here to open a configuration form
g. Enter the user access code that will be used
h. Save the configuration
Note: there is an icon in the Component type list box. This icon
represents the status of the
component.
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
5
Note: The EntraPass system can only download information from the
intrusion panel while it is disarmed. If the intrusion panel is
armed, EntraPass will buffer the modification until the intrusion
panel disarms.
Arming and disarming via manual operations:
To request an arming or disarming of partitions, go to the
Operation tab and select Integrated component
a. If shown, on the left pane select the proper intrusion
panel
b. In the right pane, select the partition you wish to arm or
disarm
c. Right click on the partition and select a task
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
6
Intrusion on Graphics:
To view a virtual keypad or intrusion components from a graphic, go
to the Definition tab and select the Graphic button
a. Create a new graphic or choose the appropriate graphic from the
Graphic drop
down list
b. Click the Click here to create, edit or modify a graphic
button
c. Drag and drop the Panel component icon on the graphic
screen
d. Select the Keypad from the list box
Note: You may also add zones and partitions on the graphic. You may
arm and disarm partitions by setting default double click
functions.
e. Close the window by clicking on the X at the top
f. Save the graphic
g. You may view a graphic from the graphic desktop
Viewing events and reports:
1. To view intrusion events, go to the Desktop tab and select
Desktop 1 Button.
a. From the Message list, you can view all the access and intrusion
events.
b. To view only access or intrusion events, click on the All Events
button and select
the proper event type
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
7
2. You may generate reports, video trigger, real time email
notifications and alarm
acknowledgments based on intrusion events. You can better search
for events by
sorting by access control events or intrusion events in the above
mentioned windows.
Single Partition Management (by partition) via a Reader:
To arm a single partition via a reader, go to the Devices tab and
click the Door button a. Make the appropriate Gateway, Site and
Controller selections, and select the
door used for arming/disarming the partition
b. Go to the Options and alarm system tab and click the External
alarm system
options button
i. For arming:
1) If you are arming via card and pushing button, choose the
appropriate input in the Arming request Input
2) If you are arming via card and keypad button, choose the
appropriate button to be used as an arming request in the
keypad button drop down list
ii. Choose when cardholders will be able to arm the intrusion
system by
choosing a schedule in the Enable Arming Request schedule
textbox
iii. Choose which card holder will be able to arm the intrusion
system by
choosing a single access level, or group of access levels, in the
Arming
access level textbox
iv. Go to the Disarming request tab and choose which card holder
will be
able to disarm the intrusion system, by choosing a single access
level or
group of access levels in Postpone or disarm access level
textbox
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
8
v. Go to the Partitions tab and under the Partition to arm textbox
select
the partition associated to this door.
vi. Check the Authorize disarming during exit delay if you want to
be able
to disarm during an exit delay
vii. Press Ok and save the door.
Note: The default user code programmed earlier in step 2.f is used
as the user code for arming and disarming of the partitions.
PLEASE NOTE: THERE IS NO VIRTUAL KEYPAD WITH THE NEO
INTEGRATION.
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
9
Virtual Zones Programming (Single Panel): DSC PowerSeries Neo
allows the assignment of up to 32 of its total zones as virtual
zones. A DSC PowerSeries Neo zone can be “triggered” in Alarm,
Trouble, Tamper by Kantech inputs, doors or controller events using
Virtual zones. The benefit is that a Kantech Controller Door can
cause an event on a DSC PowerSeries Neo zone without any wiring,
and transmit the event to the monitoring central station if needed.
Note - the following Firmware is required:
o KT-400 Firmware 1.17 or higher
o KT-400 rev1 Firmware 1.23 or higher
o KT-1-M or PCB Firmware 1.03 or higher
Note: HS2016 can only have 16 virtual zones The following steps
describe the method to program a single panel as a virtual
zone:
1. DSC Virtual zones need to be assigned to a DSC physical zone
using the DSC
keypad using option
c. Choose the physical zone to be linked: ex: 009
d. Press # when done
2. Go to the Devices tab and select the Integrated Panel
button
a. Select the previously created DSC PowerSeries Neo panel
b. Click the Panel Component tab
c. Under Virtual zone select the number of virtual zones you
have
d. Save the integration module
3. Go to the Devices tab and select the Integrated Component
button.
a. Select the appropriate Virtual Zone in the Component dropdown
list
b. Click on Click here to open the configuration form
c. Choose the Kantech component type to link in the Component type
dropdown list
d. Choose the Kantech component in the Component source
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
10
e. Check the proper DSC Component action the Virtual zone will
cause on the DSC
PowerSeries Neo
g. Save the virtual zone
Virtual Zones Programming (Multiple Panels): The following
describes the method to program a multiple panels as virtual zones
using the virtual zone mapping window: In order to link components
from multiple controllers, the gateway will manage or supervise the
events of all controllers, other than the one where the Neo panel
is used. The virtual zone mapping window will now be populated with
all appropriate devices. When opening the mapping of components to
a virtual zone, the list of components is based on the devices of
the same gateway and same account where the Neo panel is used. For
example, doors: the doors will be listed where Neo is connected,
along with and doors of all the other controllers using the same
gateway.
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
11
The Gateway will monitor the events from the other controllers and
send commands to the KT’s DLL to update the virtual zone,
accordingly.
Using this connectivity, where the gateway is sending commands to
Neo (through a KT-1 or KT-400), it is possible to interact with all
types of controllers on that gateway (KT-100, KT- 200, KT-300),
even if connected through RS-485 bus.
Gateway
Server
KT-1
gateway based on the normal process.
Integration DLL at the gateway level
process link between EntraPass Controller-
Door-Input and, if required, send command
to the KT/NEO interface to change the
steate of the virtual input on the NEO
panel.
IP / 485
IP / 485
IP / 485
IP / 485
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
12
EntraPass DSC PowerSeries Neo
REPORT TROUBLE
REPORT TAMPER
Input tamper in alarm (only Double EOL) X
Door
Door forced open X
Door pre-alarm open too long X
Door open too long X X
Door lock device failure X
Events
Duress Duress Feature (Timed Reset) X Controllers Controller AC
power failed / Controller AC power restored X
Controllers Tamper switch in alarm / Tamper switch restored
X
Controllers Controller reader power failure / Controller reader
power restored X
Controllers Controller battery power failure / Controller battery
power restored X
Controllers Controller module communication failure /Controller
module communication restore X
Controllers Controller DC power failed / Controller DC power
restored X
Controllers Controller lock power failed / Controller lock power
restored X
Controllers Controller power trouble (KT-1) X
Door Door forced open / Door forced open Restored X
Door Door open too long / Door open too long restore X
Door Door lock device failure / door lock device failure restored
X
Access Denied Access Denied – Bad Card Status (Timed Reset) X
1 (450) 444-2030 • Toll free: 1-888-222-1560 • Fax: 1 (450)
444-2029 • www.kantech.com Copyright © 2015 Tyco International Ltd.
and its Respective Companies. • All rights reserved. Specifications
are subject to change without prior notice.
13
The PowerSeries Neo/Kantech integration provides users with the
following abilities:
Receiving programming of the intrusion system: the partition and
zone names can be uploaded to the EntraPass software from the
intrusion panel. The partitions and zones can be used for various
actions, such as operator operations. Additionally, the user codes
can be uploaded from the intrusion panel and stored in the
EntraPass software. The EntraPass operator can program and download
new user codes to the intrusion panel or modify existing
ones.
Receiving events from the intrusion panel: the intrusion panel
events can be viewed on the message list, and be used for reporting
in conjunction with the standard access events. Furthermore, these
intrusion events can be used to trigger video recordings, pop-up
alarms, email notifications and other actions.
Manual operations from EntraPass: the operator can perform manual
operations on partitions from the EntraPass software, operations
such as: Partition arm away, partition arm stay, partition arm no
entry delay, partition arm with code, and disarm partition with
code.
Using intrusion components on graphics: the uploaded zones and
partitions can be used in graphic floor plans to visualize where
each zone, partitions and traditional access control components,
are located on the floor plan. The operator can view the status of
each of the components and perform operations on partitions.
Arm and disarm partitions: the intrusion panel partition can be
linked to a reader or readers to request an arming and disarming of
the partition via a card. When a card holder presents a card and
pushes the appropriate button on the reader, the KT- 400/KT-1 will
send an arming request to the intrusion panel. When a card holder
presents a card and opens the doors, the KT controller will send a
disarming request to the intrusion panel. The EntraPass software
supports single partition management per reader or multiple
partition management per reader.