EasyClean & EasyClean+ LST Radiant Skirting HeatingInstallation Instructions

Follow these instructions to ensure a simple, safe and secure installation of your EasyClean heating system.

Before you start:

Recommended order of installation.

1. 1stfixfeedandreturnpipeworkinaccordancewithattachedtemplate(P6,7&8)andwithreferencetothetimberground/base.

2. Installationof22mm(or19mm–seebelow)Timbergroundofheighttosuitspecificationusually100mm(4”)or150mm(6”).

3. Flooring–usuallyvinylof2~3mmonto38mmradiusfloorcoving.

4. Wallcovering–usually2mmvinylfrom1.2mhighdowntotimberground.

5. EasyCleaninstallation.Seethefollowinginstructions.

Security Top StripProvides simple wipe down with no gaps or spaces to trap and harbour infection

Flexible Vinyl LipIntegrates into vinyl

flooring foreasy cleaning

Timber BattonUsually 100-150mmto suit installation

Top FixingSecures radiant

panel to wall

Centre FixingSecures radiant

panel to wall

Bottom FixingSecures radiant

panel to wall

YourThermaSkirtsystemmustbecleansedandprotectedbyacorrosioninhibitorsuitableforalluminiumradiators,asrequiredbyBS7593:2006‘CodeofPracticefortreatmentofwaterindomestichotcentralheatingsystems’.DiscreteHeatrecommendsourownTS3CleanserandTS5InhibitororScalemasterCM5orCM10.FAILURE TO PROTECT YOUR SYSTEM WILL INVALIDATE YOUR WARRANTY

6mmgapA) Securing the bottom hygienic mounting rail

Usingtheextruded6mlengths,cuttosize.Ininternalcorners,thereisnoneedtomitretheends,butleavenomorethana25mm(1”)clearancefromendtowall.Externalcornersshouldbemitred,butavoidcreatingasharpedgebyleavinga6mm(1/4”)gapwhichwillbesealedwithanti-pickmastic.

Securethebottomrailtothewallatregularintervals(800~1,000mm/3’~3’3”)alongthelengthandnomorethan150mm(6”)fromanyend,usingappropriatescrewsandrawlplugsifrequired.Ifspecified,thebottomsealedgecanbebondedtotheflooringforaperfecthygienicbarrier.

B) Cutting the EasyClean radiant panels to length

Usethefollowingcuttingallowancesforthevariousconnectorsandjointstocalculatethecorrectlengthofeachpanel.

Deburring the panels

C) EasyClean+ installation Only (For EasyClean, please go to Section G)

NOTE:EasyClean+lowerpanelismounted‘upsidedown’withtheopenedgeupwards,inordertoreceivetheuppersection.

Withtheappropriateconnectors(andclip)inserted,locatethebottomradiantpanelontothebottommountingrail,andmoveontothenextpanel,workingawayfromthefeedandreturnpoint.Ensurethatwhenconnectingcornersandin-linejointstheconnectorclipisproperlylocatedontothe‘pegs’ofthemouldedfitting.

TIP: If any of the mounting rails interfere with the elbows or return manifold, then the mounting rail can be nibbled away using pincers.

0~3mm (0.0") 80mm (2") 100mm (4")

20mm (0.8")50-55mm(2-2.16")

120mm (5")

35mm 20mm

TRV Feed/return Internal corner External corner Return manifold

Odd angle - internal Odd angle - external In-line joint (> 6m walls) Door architrave kit

Non TRV feed & return /threshold kit

115mm (min)

50-55mm (2-2.16")

Minimum activelength = 55mm (2.16")

DEBURR!

Keep parallel

Deburring tool(Part No. STOOL)

!‘Bell Mouth’ deburr

Remove all chaffand debris

andrew
Typewritten Text
(Position Wall Mounting Bracket 10mm from end to hold cover in place)
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text
andrew
Typewritten Text

E) Fixing the intermediate mounting rail. (EasyClean+ only)

Withallthelowerradiantpanelsinstalledandconnected,cutthe6mlengthsoftheintermediatemountingrailtosuit.

Withthe‘longleg’up,gentlytaptherailintothegrooveontheupturnedEasyCleanpanel,usingasoftfacemalletorsimilar.

Whenclippedintothegroove,securetheintermediaterailtothewallevery1,000mm(3’3”)orsousingsuitablescrewsandfixings.

F) Installing the upper (EasyClean+ only)

UsingthecuttingallowancesfromSectionB,cuttheupperEasyCleanradiantpanelsanddeburrproperly.InthesamewayasinSectionC,withtheappropriateconnectorsandclipsinserted,installthesectionsstartingfromthefeedandreturnpoint,andmovingaroundtheroom.Connectsectionstogetherbeforefullylocatingdownontothemountingrail.

Whencomplete,tapthebottomedgeoftheEasyCleanpanelontotheintermediaterail,usingasoftfacemalletorsimilar.Ensurethereisnogapbetweentheupperandlowersections.

G. Installing the top Security mounting rail (Easy Clean & EasyClean+)

Cutthe6mtopmountingrailstotheappropriatelengths.Atinternalcornersamitreisnotrequired,butnomorethan25mm(1”)clearanceshouldbeallowed.Atexternalcornersitispreferabletocuttothecorner.DropthetopSecurityrailintothetopchanneloftheEasyCleanpanel,andclickhome.Securethesecurityrailtowallusingappropriatefixingsevery800~1,000mm(3’~3’3”),butnonearerthan150mm(6”)fromanend,cornerorjoint.

H) Installing the stainless steel covers (EasyClean & EasyClean+)

Note:Itissuggestedthatthesystembefilledandpressuretestedbeforethecoversarefitted.Systemsshouldbecleansedandinhibitedtopreventchemicalcorrosion.(SeePage1)

COVERSMUSTBEFITTEDBEFORETHETOPSECURITYCAPPING!

Thestainlesssteelcoveredgesshouldbeinsertedbetweenthebottom/topoftheEasyCleanpanelsandthebottom/topmountingrails.Iftherailshavebeenfixedcorrectlywithafixingscrewnocloserthan150mm(6”)fromthejoint,thereshouldbesufficient‘give’toallowthecoverstosqueezeinandlatchon.Asoftfacemalletorsimilarmaybeused,butonlyatthefoldededgesofthecoversandnotinthemiddletoavoiddistortion.

I) Fitting the top Security Capping (EasyClean & EasyClean+)

Note:ItisstronglyrecommendedthatthesystemisfilledandpressuretestedbeforetheTopSecurityCappingisinstalled.Systemsshouldbecleansedandinhibitedtoavoidchemicalcorrosion.(SeePage1)

Cutthe6msectionstotheappropriatelengths.Atinternalcornersasmallgapofupto6mm(1/4”)maybelefttoaidinstallation,whichmustbesubsequentlysealedwithanti-pickmastic.Atexternalcornersagapof8~10mm(1/3”~3/8”)shouldbelefttoavoidcreatingasharpcorner.ThisgapMUSTbesubsequentlysealedwithanti-pickmastic.

ToinstalltheSecuritycapping(startingfromthefeedandreturnpoint)

1. LocatethetopclipofthecappingintothehorizontalgrooveintheSecuritymountingrail.

2. RotatetheCappingtowalluntilthebottomclipmeetstheretaininggroove.

3. Pushhard.Youwillhear/feelasolidclick.Workyourwayalongthelength,ensuringeachsectionisfull‘snapped’home.

4. Thetopedgeofthecappingisformedasaflexiblegaskettoprovideawaterresistantsealtothewall.Additionalsealantsarethereforenotnormallyrequired.

The Skirting Board that heats your home

®

www.discreteheat.co.uk Tel: 01942 880066 info@discreteheat.co.uk1 V i c t o r i a Wo r k s I n d u s t r i a l E s t a t e , C o a l P i t L a n e ,A t h e r t o n ,M a n c h e s t e r M 4 6 0 F Y

J. Removing Security Capping. (EasyClean & EasyClean+)

Thesecuritycappingisdesignedtoprovideahighdegreeofsafety,securityandanti-ligature.AsaresultremovaloftheSecurityCappingisdeliberatelydifficultandonlypossiblewithsuitabletools.Discreterecommendsaflatbladedpaintscraperorsimilar(whichwouldnotordinarilyavailabletooccupants).

a) Carefullyslidethepaintscraperbladebetweenwallcoveringandtopseal

b) Locatingontothecappingmoulding,pushdownhard&

c) Twisttheblade,usingthewallasleveragetoforcethecappingofthesecurityrail.

d) Repeat,movingdownthelengthofthecapping,releasingsmallsectionsatatime.

e) Onceareasonablelength(1morso)hasbeenreleaseditshouldbepossibletopeelthesecuritycappingoffthesecurityrail.

K. Maintaining & Cleaning your EasyClean System. (EasyClean & EasyClean+)

Thesystemhasbeendesignedanddevelopedtobemaintenancefree.Apartfrommaintaininginhibitorinthesystemtopreventchemicalcorrosion,therearenopartstomaintain.

Cleaningisasimplewipedownwithordinarycleaningmaterialssuchasanti-bacterialsprays,mildbleachsolutionsoranyreasonablydilutedcleansersaspartofthenormalcleaningcycle.

Thepaintfinishisepoxypowdercoatingandsoisresistanttoallbutthemostaggressivethinnersandpaintstrippers.Thetop&bottommountingrailsareUpVCandaretoleranttoallcleaninganddisinfectantsordinarilyfoundinthehealthcaresector.VeryaggressivechemicalsandsolventssuchasMeK,orthinnersshouldbeavoided.

8-10mmgap

6mmgap

90

Street Elbow

Street Elbow

Elbow

Elbow

Straight Connector

90

2