Post on 22-Mar-2021
transcript
1 w w w. m o x a . c o m i n f o @ m o x a . c o m
Industrial Ethernet Solutions
EDS-G509 Series
IntroductionThe EDS-G509 is equipped with 9 Gigabit Ethernet ports and up to 5 fiber optic ports, making it ideal for upgrading an existing network to Gigabit speed or building a new full Gigabit backbone. Gigabit transmission increases bandwidth for higher performance and transfers large amounts of video, voice, and data across a network quickly. Redundant Ethernet Turbo Ring and RSTP/STP (IEEE
4 10/100/1000BaseT(X) ports plus 5 combo (10/100/1000BaseT(X) ›or 100/1000BaseSFP slot) Gigabit ports
Fiber optic options for extending distance and improving electrical ›noise immunity
Turbo Ring, RSTP/STP (IEEE 802.1w/D) for Ethernet redundancy ›QoS, IGMP snooping/GMRP, VLAN, LACP, SNMPv1/v2c, RMON ›supported
SNMPv3, HTTPS, SSH, IEEE 802.1X, and port security supported ›
IPv6 Ready logo awarded (IPv6 Logo Committee certified)•IEEE 1588 PTP (Precision Time Protocol) for precise time •synchronization of networksDHCP Option 82 for IP address assignment with different policies•Modbus/TCP industrial Ethernet protocol supported•IEC 61850 GOOSE messaging compliance •Turbo Ring and RSTP/STP (IEEE 802.1w/D)•IGMP snooping and GMRP for filtering multicast traffic•Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network •planningQoS (IEEE 802.1p/1Q) and TOS/DiffServ to increase determinism•
Port Trunking for optimum bandwidth utilization•SNMPv3, IEEE 802.1X, HTTPS, and SSH to enhance network •securitySNMPv1/v2c/v3 for different levels of network management•RMON for efficient network monitoring and proactive capability•Bandwidth management prevents unpredictable network status•Lock port function for blocking unauthorized access based on MAC •addressPort mirroring for online debugging•Automatic warning by exception through e-mail, relay output•ABC-01 (Automatic Backup Configurator) for system configuration •backup
Specifications
9G-port full Gigabit managed Ethernet switches
802.1w/D) increase system reliability and the availability of your network backbone. The EDS-G509 series is designed especially for communication demanding applications, such as video and process monitoring, shipbuilding, ITS, and DCS systems, all of which can benefit from a scalable backbone construction.
Features and Benefits
TechnologyStandards: IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100Base FX IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseSX/LX/LHX/ZX/EZX IEEE 802.3x for Flow Control IEEE 802.1D for Spanning Tree Protocol IEEE 802.1w for Rapid STP IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACPProtocols: IGMPv1/v2 device, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, Modbus/TCP (Available Soon: SNMP Inform, LLDP, IEEE 1588 PTP, IPv6)MIB: MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9Flow Control: IEEE 802.3x flow control, back pressure flow control
Switch PropertiesPriority Queues: 4Max. Number of Available VLANs: 64VLAN ID Range: VID 1 to 4094IGMP Groups: 256
Interface Fiber Ports: 100/1000BaseSFP slotRJ45 Ports: 10/100/1000BaseT(X) auto negotiation speedConsole Port: RS-232 (RJ45 connector)DIP Switches: Turbo Ring, Master, Coupler, ReserveLED Indicators: PWR1, PWR2, FAULT, 10/100/1000M, MASTER, COUPLERAlarm Contact: 2 relay outputs with current carrying capacity of 1 A @ 24 VDC Digital Inputs: 2 inputs with the same ground, but electrically isolated from the electronics. •+13to+30Vforstate“1” •-30to+3Vforstate“0” •Max.inputcurrent:8mA
2 w w w. m o x a . c o m i n f o @ m o x a . c o m
Industrial Ethernet Solutions
Dimensions (unit = mm)
Ordering Information
107 87.1
9.5
135
87.1
Side View Front View Rear View DIN-Rail/Panel Mounting Kit
Available ModelsEDS-G509: Industrial full Gigabit managed Ethernet switch with 4 10/100/1000BaseT(X) ports, and 5 10/100/1000BaseT(X) or 100/1000BaseSFP slot combo ports, 0 to 60°C operating temperatureEDS-G509-T: Industrial full Gigabit managed Ethernet switch with 4 10/100/1000BaseT(X) ports, and 5 10/100/1000BaseT(X) or 100/1000BaseSFP slot combo ports, -40 to 75°C operating temperatureNote: The EDS-G509 series switches support up to 5 100/1000BaseSFP slots. See page 3-45 and 3-47 for SFP-1G/1FE series Gigabit/fast Ethernet SFP module product information.
Optional Accessories (can be purchased separately)EDS-SNMP OPC Server Pro: OPC server software that works with all SNMP devicesABC-01: Configuration backup and restoration tool for managed Ethernet switches, 0 to 60°C operating temperatureDR-4524/75-24/120-24: 45/75/120 W DIN-Rail 24 VDC power suppliesMDR-40-24/60-24: 40/60 W DIN-Rail 24 VDC power supplies, -20 to 70°C operating temperatureWK-46: Wall mounting kitRK-4U:4U-high19”rackmountingkit
Power RequirementsInput Voltage: 12/24/48 VDC redundant dual inputsInput Current: 0.81 A @ 24 VOverload Current Protection: PresentConnection: 2 removable 6-contact terminal blocks Reverse Polarity Protection: Present
Physical Characteristics Housing: Metal, IP30 protectionDimensions: 87.1 × 135 × 107 mm (3.43 × 5.31 × 4.21 in)Weight: 1510 gInstallation: DIN-Rail mounting, wall mounting (with optional kit)
Environmental LimitsOperating Temperature: Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) for T modelsStorage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing)
Regulatory Approvals Safety: UL508 (Pending), EN60950-1
Hazardous Location: UL/cUL Class I, Division 2, Groups A, B, C, and D (Pending); ATEX Zone 2, Ex nC IIC (Pending)EMI: FCC Part 15, CISPR (EN55022) class AEMS: EN61000-4-2 (ESD), level 3 EN61000-4-3 (RS), level 3 EN61000-4-4 (EFT), level 3 EN61000-4-5 (Surge), level 3 EN61000-4-6 (CS), level 3 EN61000-4-8 EN61000-4-11Maritime: DNV (Pending), GL (Pending)Shock: IEC 60068-2-27 Freefall: IEC 60068-2-32 Vibration: IEC 60068-2-6Note: Please check Moxa’s website for the most up-to-date certification status.
WarrantyWarranty Period: 5 yearsDetails: See www.moxa.com/warranty
3 w w w. m o x a . c o m i n f o @ m o x a . c o m
Industrial Ethernet Solutions
Interface Ethernet Ports: 1Connectors: Duplex LC Connector or Simplex LC Connector (WDM-type only)Note: WDM-type SFP modules must be used in pairs (e.g., SFP-1GXXALC and SFP-1GXXBLC)
Optical Fiber
Environmental LimitsOperating Temperature: Standard Models: 0 to 60°C (32 to 140°F) Wide Operating Temp. Models: -40 to 85°C (-40 to 185°F)Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing)
Regulatory Approvals Safety: UL, TÜV
WarrantyWarranty Period: 3 yearsDetails: See www.moxa.com/warranty
SFP-1G Series
Specifications
Compliant with IEEE 802.3z ›Differential LVPECL inputs and outputs ›Single 3.3 V power supply ›TTL signal detect indicator ›Hot pluggable ›Class 1 laser product, complies with EN60825-1 ›
EN : 60825
Gigabit Ethernet
SFP-SX SFP-LSX SFP-LX SFP-LH SFP-LHX SFP-ZX SFP-EZX SFP-10A SFP-10B SFP-20A SFP-20B SFP-40A SFP-40B
Wave-length 850 nm 1310 nm 1310 nm 1310 nm 1310 nm 1550 nm 1550 nm
TX 1310 nm,RX 1550 nm
TX 1550 nm,RX 1310 nm
TX 1310 nm,RX 1550 nm
TX 1550 nm,RX 1310 nm
TX 1310 nm,RX 1550 nm
TX 1550 nm,RX 1310 nm
Max. TX -4 dBm -1 dBm -3 dBm -2 dBm 1 dBm 5 dBm 5 dBm -3 dBm -2 dBm 2 dBm
Min. TX -9.5 dBm -9 dBm -9.5 dBm -8 dBm -4 dBm 0 dBm 0 dBm -9 dBm -8 dBm -3 dBm
RX Sensitivity -18 dBm -19 dBm -20 dBm -23 dBm -24 dBm -24 dBm -30 dBm -21 dBm -23 dBm -23 dBm
Link Budget 8.5 dB 10 dB 10.5 dB 15 dB 20 dB 24 dB 30 dB 12 dB 15 dB 20 dB
Typical Distance 550 m a 2 km b 10 km c 30 km c 40 km c 80 km c 110 km c 10 km c 20 km c 40 km c
Saturation 0 dBm -3 dBm -3 dBm -3 dBm -3 dBm -3 dBm -3 dBm -1 dBm -1 dBm -1 dBm
1G-port Gigabit Ethernet SFP modules
a. 50/125 μm, 400 MHz * km or 62.5/125 μm, 500 MHz * km @ 850 nm multi-mode fiber optic cableb. 62.5/125 μm, 750 MHz * km @ 1310 nm multi-mode fiber optic cablec. 9/125 μm single-mode fiber optic cable
4 w w w. m o x a . c o m i n f o @ m o x a . c o m
Industrial Ethernet Solutions
Ordering Information
WDM-type (BiDi) SFP ModulesAvailabe Models Port Interface
Standard Temperature(0 to 60˚C)
Wide Temperature(-40 to 85˚C)
1000BaseSFP,
LC Connector, 10 km
1000BaseSFP,
LC Connector, 20 km
1000BaseSFP,
LC Connector, 40 kmTX 1310 nm, RX 1550 nm
TX 1550 nm, RX 1310 nm
TX 1310 nm, RX 1550 nm
TX 1550 nm, RX 1310 nm
TX 1310 nm, RX 1550 nm
TX 1550 nm, RX 1310 nm
SFP-1G10ALC SFP-1G10ALC-T 1 --- --- --- --- ---
SFP-1G10BLC SFP-1G10BLC-T --- 1 --- --- --- ---
SFP-1G20ALC SFP-1G20ALC-T --- --- 1 --- --- ---
SFP-1G20BLC SFP-1G20BLC-T --- --- --- 1 --- ---
SFP-1G40ALC SFP-1G40ALC-T --- --- --- --- 1 ---
SFP-1G40BLC SFP-1G40BLC-T --- --- --- --- --- 1
SFP ModulesAvailable Models Port Interface
Standard Temperature(0 to 60˚C)
Wide Temperature(-40 to 85˚C)
1000BaseSX, LC Connector,
0.5 km
1000BaseLSX,
LC Connector, 2 km
1000BaseLX, LC Connector,
10 km
1000BaseLH,
LC Connector,
30 km
1000BaseLHX,
LC Connector, 40 km
1000BaseZX,
LC Connector, 80 km
1000BaseEZX,
LC Connector, 110 km
SFP-1GSXLC SFP-1GSXLC-T* 1 --- --- --- --- --- ---
SFP-1GLSXLC SFP-1GLSXLC-T --- 1 --- --- --- --- ---
SFP-1GLXLC SFP-1GLXLC-T --- --- 1 --- --- --- ---
SFP-1GLHLC SFP-1GLHLC-T --- --- --- 1 --- --- ---
SFP-1GLHXLC SFP-1GLHXLC-T --- --- --- --- 1 --- ---
SFP-1GZXLC SFP-1GZXLC-T --- --- --- --- --- 1 ---
SFP-1GEZXLC --- --- --- --- --- --- --- 1
The SFP-1G series modules can be used with the following productsEDS-728/828 series: IM-2GSFP series Gigabit Ethernet interface modulesEDS-G509 series: 9G-port full Gigabit managed Ethernet switchesEDS-518A series:16+2G-portGigabitmanagedEthernetswitchesEDS-510A series:7+3G-portGigabitmanagedEthernetswitchesEDS-P510 series:7+3G-portGigabitPoEmanagedEthernetswitchesPT and IKS series: PM-7200-2G/4G series Gigabit Ethernet interface modulesEDS-G308 series: 8G-port full Gigabit unmanaged Ethernet switchesIMC-101G series: Industrial Gigabit media converters
Note: SFP-1GSXLC-T: -20 to 75˚C operating temperature
Side ViewTop View
4555.556.6
6.25RXTX
13.3
5
8.2
0.6
0.4
13.4
8.40
1.68
13.7
1414
.60.
4
8.45
Dimensions (unit = mm)
Side View
Rear View
Top View
5
Industrial Ethernet Solutions
© Moxa Inc. All Rights Reserved. Updated Jul. 29, 2009. Specifications subject to change without notice. Please visit our website for the most up-to-date product information.
Interface Ethernet Ports: 1Connectors: Duplex LC Connector
Optical Fiber
Environmental LimitsOperating Temperature: -40 to 85°C (-40 to 185°F)Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing)
Regulatory Approvals Safety: UL, TÜV
SFP-1FE Series
Specifications
Single + 3.3 V power Supply ›Small From Factor Pluggable MSA Compliant ›PECL Differential Inputs and Output ›TTL Signal Detect Indicator ›Compliant with SONET / SDH Standard ›LC Duplex Connector ›EEPROM with serial ID functionality ›Class 1 Laser International Safety Standard IEC 825 Compliant ›
Fast Ethernet
SFP-M SFP-S SFP-L
Wavelength 1300 nm 1310 nm 1550 nmMax. TX -18 dBm 0 dBm 0 dBm
Min. TX -8 dBm -5 dBm -5 dBm
RX Sensitivity -34 dBm -34 dBm -34 dBm
Link Budget 26 dB 29 dB 29 dB
Typical Distance 4 km a 40 km b 80 km b
Saturation 0 dBm -3 dBm -3 dBm
a. 50/125 μm or 62.5/125 μm, 800 MHz * km @ 1300 nm multi-mode fiber optic cable b. 9/125 μm single-mode fiber optic cable
1-port fast Ethernet SFP modules
Ordering Information
Available Models Port Interface
Wide Temperature(-40 to 85˚C)
100BaseFX, Multi-mode,
LC Connector, 4 km
100BaseFX, Single-mode,
LC Connector, 40 km
100BaseFX, Single-mode,
LC Connector, 80 km
SFP-1FEMLC-T 1 --- ---
SFP-1FESLC-T --- 1 ---
SFP-1FELLC-T --- --- 1
EN : 60825
Side View
Top View
4555.556.6
6.25RXTX
13.3
5
8.2
0.6
0.4
13.4
8.40
1.68
13.7
1414
.60.
4
8.45
Dimensions (unit = mm)
Rear View
Side View
Top View
WarrantyWarranty Period: 3 yearsDetails: See www.moxa.com/warranty
The SFP-1FE series modules can be used with the following productsEDS-G509 series: 9G-port full Gigabit managed Ethernet switchesEDS-G308 series: 8G-port full Gigabit unmanaged Ethernet switchesEDS-P510 series:7+3G-portGigabitPoEmanagedEthernetswitchesPT and IKS series: PM-7200-8SFP fast Ethernet interface modules