EE 5223 - Lecture 15 Ongoing List of Topics

Post on 12-Apr-2022

1 views 0 download

transcript

EE 5

223

- Lec

ture

15

Fri F

eb 1

2, 2

021

Ong

oing

Lis

t of T

opic

s:

•U

RL:

http

://w

ww

.ece

.mtu

.edu

/facu

lty/b

amor

k/EE

5223

/inde

x.ht

m

•Te

rm P

roje

ct -

stru

ctur

ing,

det

ails

•Ex

erci

ses

post

ed

Toda

y:

•R

eclo

sing

- ra

dial

vs.

grid

sys

tem

•Sh

ort c

ircui

t pro

tect

ion

in g

rid s

yste

ms

•D

irect

iona

l ove

rcur

rent

•Im

peda

nce

•Vo

ltage

& C

urre

nt re

latio

nshi

ps d

urin

g fa

ults

, §3.

5-3.

10•

X/R

ratio

, dc

offs

et, d

ecay

of d

c of

fset

Rel

ativ

e an

gles

and

mag

nitu

des

of a

ll Vs

& Is

dur

ing

faul

t •

Basi

c co

nnec

tions

of d

irect

iona

l ove

rcur

rent

(67)

rela

ys.

•Ph

ase

rela

ys -

each

line

cur

rent

is p

olar

ized

with

VLL

from

oth

er p

hase

s.•

Gro

und

rela

y - r

esid

ual c

urre

nt (3

I ao) p

olar

ized

with

Vbr

oken

del

ta (3

V ao)

•Ex

celle

nt Il

lust

ratio

ns: f

igur

es 3

.7 th

ru 3

.10

■OvercurrentProtectionProtect lines and equipment using a sensitive and secure mix of phase, negative-sequence, and ground overcurrent elements. Use directional control elements in looped systems. Provide high-speed operation, even with severe CT saturation, using SEL Adaptive Overcurrent Element. Apply “recloser” time-overcurrent curves for coordination with and sequencing of downstream reclosers.

■OperatorControlsandReclosingUse direct-action operator controls to eliminate the need for expensive, panel-mounted control switches and associated wiring. Integrate automation elements, including remote, local, and latch switches, plus display points, for remote and local control. Selectively reclose with synchronism and voltage checks.

■RelayandLogicSettingsSoftwareUse acSELErator® QuickSet™ SEL-5030 Software to reduce engineering costs for relay settings and logic programming. Use graphical tools included with acSELErator to develop SELogic® control equations.

■AccurateMeteringandMonitoringUse built-in, high-accuracy metering functions to eliminate expensive, separately mounted metering devices. Improve maintenance scheduling using circuit breaker contact wear and substation battery voltage monitors.

■SequentialEventsReportAnalyze Sequential Events Recorder (SER) and oscillographic event reports for rapid commissioning, testing, and post-fault diagnostics.

Making Electric Power Safer, More Reliable, and More Economical ®

Optimize Distribution Protection,Automation, and Breaker Control

SEL-351S Protection and Breaker Control Relay

Apply the SEL-351S Relay to

enhance your service quality

through integrated protection,

monitoring, and control.

Features and Benefits

Develop SELogic control equations using acSELErator Software.

Use any of the 38 traditional recloser curves in the SEL-351S Relay to time-coordinate with downstream circuit reclosers. Sequence coordination keeps the SEL-351S in step with downstream reclosers and prevents tripping by overreaching overcurrent elements for faults beyond reclosers.

Five standard US and IEC time-overcurrent curves provide coordination with other time-overcurrent relays.

Functional Overview

Coordinate Overcurrent Protective Devices

• SELOGIC® Control Equations

• Event Reports

• Sequential Events Recorder

• Breaker Wear Monitor

• Station Battery Monitor

• DNP3 Level 2 Slave*

• High-Accuracy Metering

• MIRRORED BITS® Communications*

• Communications-Assisted Tripping

• Remote and Local Control Switches

• Wye or Delta Voltage Connection

• Local Display and Operator Controls

• Synchrophasor Measurements

• Load Profile*

• Fault Locator

• Fast SER Protocol

• Auxiliary Trip/Close Control*

• Voltage Sag/Swell/Interruption Records*

• User-Configurable Labels*

• Sensitive Earth Fault Protection and Directional Protection for Various System Grounding Practices*

27 81 OU59

PGQ

67PGQ

3232QVI

51PGQ

50PGQ

67N 51N50N

27 59

SEL-351S Relay

Bus

Feeder

79

25

3

3

1

1Breaker

52

* Optional Functions

Retrofit older existing reclosers with the SEL-351R Recloser Control.

t

I

FastCurves

DelayCurves

52

RECLOSER

SEL-351S SEL-351R