AREA STATEMENT (BBMP) VERSION NO.: 1.0.9VERSION DATE: 01/11/2018
PROJECT DETAIL:Authority: BBMP Plot Use: CommercialInward_No:BBMP/Ad.Com./RJH/0152/19-20 Plot SubUse: Small Shop
Application Type: General Land Use Zone: Residential (Main)Proposal Type: Building Permission Plot/Sub Plot No.: SY NO-2/2Nature of Sanction: New City Survey No.: 2/2Location: Ring-III Khata No. (As per Khata Extract): 81Building Line Specified as per Z.R: NA Locality / Street of the property: ANDHRAHALLIAREA DETAILS: SQ.MT.
AREA OF PLOT (Minimum) (A) 6682.31Deduction for NetPlot Area
Road Widening Area 1026.68Total 1026.68
NET AREA OF PLOT (A-Deductions) 5655.63COVERAGE CHECK
Permissible Coverage area (50.00 %) 2827.81Proposed Coverage Area (9.01 %) 509.43Achieved Net coverage area ( 9.01 % ) 509.43Balance coverage area left ( 40.99 % ) 2318.38
FAR CHECKPermissible F.A.R. as per zoning regulation 2015 ( 2.50 ) 16705.77Additional F.A.R within Ring I and II ( for amalgamated plot - ) 0.00Allowable TDR Area (60% of Perm.FAR ) 0.00Allowable max. F.A.R Plot within 150 Mt radius of Metro station ( - ) 0.00Total Perm. FAR area ( 2.50 ) 16705.77Commercial FAR (100.00% ) 509.43Proposed FAR Area 509.43Achieved Net FAR Area ( 0.08 ) 509.43Balance FAR Area ( 2.42 ) 16196.34
BUILT UP AREA CHECKProposed BuiltUp Area 509.43Achieved BuiltUp Area 509.44
Approval Date : 05/21/2019 2:28:23 PM
Payment Details
Sr No. ChallanNumber
ReceiptNumber Amount (INR) Payment Mode Transaction
NumberPayment Date Remark
1 BBMP/2111/CH/19-20 BBMP/2111/CH/19-20 3574 Online 8452088037 05/15/201910:43:19 AM -
No. Head Amount (INR) Remark1 Scrutiny Fee 3574 -
Approval Condition :
This Plan Sanction is issued subject to the following conditions :
1.Sanction is accorded for the Commercial Building at SY NO-2/2 , ANDHRAHALLI, Bangalore. a).Consist of 1Ground + 0 only.2.Sanction is accorded for Commercial use only. The use of the building shall not be deviated to any other use.3.137.50 area reserved for car parking shall not be converted for any other purpose.4.Development charges towards increasing the capacity of water supply, sanitary and power main has to be paid to BWSSB and BESCOM if any.5.Necessary ducts for running telephone cables, cubicles at ground level for postal services & space for dumping garbage within the premises shall be provided.6.The applicant shall INSURE all workmen involved in the construction work against any accident / untoward incidents arising during the time of construction.7.The applicant shall not stock any building materials / debris on footpath or on roads or on drains. The debris shall be removed and transported to near by dumping yard.8.The applicant shall maintain during construction such barricading as considered necessary to prevent dust, debris & other materials endangering the safety of people / structures etc. in & around the site.9.The applicant shall plant at least two trees in the premises.10.Permission shall be obtained from forest department for cutting trees before the commencement of the work.11.License and approved plans shall be posted in a conspicuous place of the licensed premises. The building license and the copies of sanctioned plans with specifications shall be mounted on a frame and displayed and they shall be made available during inspections.12.If any owner / builder contravenes the provisions of Building Bye-laws and rules in force, the Architect / Engineer / Supervisor will be informed by the Authority in the first instance, warned in the second instance and cancel the registration if the same is repeated for the third time.13.Technical personnel, applicant or owner as the case may be shall strictly adhere to the duties and responsibilities specified in Schedule - IV (Bye-law No. 3.6) under sub section IV-8 (e) to (k).14.The building shall be constructed under the supervision of a registered structural engineer.15.On completion of foundation or footings before erection of walls on the foundation and in the case of columnar structure before erecting the columns "COMMENCEMENT CERTIFICATE" shall be obtained.16.The building should not be occupied without obtaining "OCCUPANCY CERTIFICATE" from the competent authority.17.Drinking water supplied by BWSSB should not be used for the construction activity of the building.18.The applicant shall ensure that the Rain Water Harvesting Structures are provided & maintained in good repair for storage of water for non potable purposes or recharge of ground water at all times having a minimum total capacity mentioned in the Bye-law 32(a).19.If any owner / builder contravenes the provisions of Building Bye-laws and rules in force, the authority will inform the same to the concerned registered Architect / Engineers / Supervisor in the first instance, warn in the second instance and cancel the registration of the professional if the same is repeated for the third time.20.The Builder / Contractor / Professional responsible for supervision of work shall not shall not materially and structurally deviate the construction from the sanctioned plan, without previous approval of the authority. They shall explain to the owner s about the risk involved in contravention of the provisions of the Act, Rules, Bye-laws, Zoning Regulations, Standing Orders and Policy Orders of the BBMP.21.In case of any false information, misrepresentation of facts, or pending court cases, the plan sanction is deemed cancelled.
Special Condition as per Labour Department of Government of Karnataka vide ADDENDUM (HosadaagiHoodike) Letter No. LD/95/LET/2013, dated: 01-04-2013 :
1.Registration of Applicant / Builder / Owner / Contractor and the construction workers working in the construction site with the "Karnataka Building and Other Construction workers Welfare Board"should be strictly adhered to.2.The Applicant / Builder / Owner / Contractor should submit the Registration of establishment and list of construction workers engaged at the time of issue of Commencement Certificate. A copy of the same shall also be submitted to the concerned local Engineer in order to inspect the establishment and ensure the registration of establishment and workers working at construction site or work place.3.The Applicant / Builder / Owner / Contractor shall also inform the changes if any of the list of workers engaged by him.At any point of time No Applicant / Builder / Owner / Contractor shall engage a construction worker in his site or work place who is not registered with the "Karnataka Building and Other Construction workers Welfare Board".
Note :
1.Accommodation shall be provided for setting up of schools for imparting education to the children of construction workers in the labour camps / construction sites.2.List of children of workers shall be furnished by the builder / contractor to the Labour Department which is mandatory.3.Employment of child labour in the construction activities strictly prohibited.4.Obtaining NOC from the Labour Department before commencing the construction work is a must.5.BBMP will not be responsible for any dispute that may arise in respect of property in question.6.In case if the documents submitted in respect of property in question is found to be false or fabricated, the plan sanctioned stands cancelled automatically and legal action will be initiated.
SHEET NO : 1
DRAWING TITLE : 1669321128-18-05-201901-15-33$_$PETROLBUNK
PROJECT TITLE :THE PLAN OF PROPOSED ;BHARAT PETROLEUMAT SY : 2 / 2 , KATHA NO : 81 , ANDRA HALLI VILLAGE, BANGALORE ,WARD NO-40.
:
MALLU MADHUSUDHAN REDDY#2, LEVEL 2, SB COMPLEX, NEXTTO IYER SCHOOL, HMT MAINROAD, MATHIKERE. BCC/BL-3.6/E-4003/2014-15
Sri.PRAKASH.,Sri.P.MANJUNATHA,LEASER:Smt.KAVYA.S.D.AADHAAR NO-6436 5444 3446NO-201,NEAR SARKARI SCHOOL,ANDRAHALLLI
ASSISTANT DIRECTOR OF TOWN PLANNING ( ________ )
BHRUHAT BENGALURU MAHANAGARA PALIKE
Validity of this approval is two years from the date of issue.
The plans are approved in accordance with the acceptance for approval bythe Joint Commissioner ( _______ ) on date: _______________ videlp number: ________________________________________ subject toterms and conditions laid down along with this building plan approval.
3.00
4.006
.
3
0
m
3.00
4.00
7.00m8.82m
6
.
0
0
m
3.00
4.00
8.48m
9.74m8.82m
3.00
4.006
.
3
0
m
3.00
4.00
14.14m8.82m
16.88m8.82m
1.5
0m
1.50m
1.50m
R4.0000m
R4.0000m
3.46m
6.92m
8.15m
4.69m
3.96m
2.96m
1.50m
8.8
5m
7
.
1
4
m
2.26m
2.00
21
.5
0m
26.16m
10
.9
3m
8.0
0m
8.0
0m
8.48m
10
.5
7m
17.61m
9
.
4
6
m
RAIN WATERHARVESTING WELLTRENCH
5.23m
5
.0
0
m
5.00m
7
.
5
0
m
F
O
R
R
O
A
D
W
I
D
E
N
I
N
G
EXISTING.18.28M WIDE ROADPROPOSED.30.00M WIDE ROAD
GROUND FLOOR PLAN
7.50 m FOR ROAD W
IDENING
4
6
.1
7
m
46.88m
2
5
.8
8
m
7
.2
2
m
1
5
.
1
3
m
1
4
.
4
3
m
8
.
5
9
m
6
.
3
6
m
1
.9
6
m
6.86m
1
3
.4
6
m
27.6
8m
14.6
7m
15.73m
17.26m
50.28m
26.2
1m
16.69m
40mm stone aggregate
Coarse sand
20mm stone aggregate
Fine sand layer 0.1m depthEmpty space 0.1m depthBore well 0.15m O
Percolation pit 1.00m OFine sand
20mm stone aggregate
Coarse sand
40mm stone aggregate
Casing pipe
SITE PLAN (Scale = 1:200)
7.9
7m
R
O
A
D
W
I
D
E
N
I
N
G
A
R
E
A
-
1
0
2
6
.
7
9
S
q
m
ROAD WIDENING
AREA-1026.79 Sqm
5
.
0
0
m
FIRE
EXTINGUISHER3.00
4.00
FIRE
EXTINGUISHER
6
.
3
0
m
3.00
4.00
FIRE
EXTINGUISHER
7.00m8.82m
6
.
0
0
m
3.00
4.00
FIRE
EXTINGUISHER
8.48m
9.74m8.82m
FIRE
EXTINGUISHER3.00
4.00
FIRE
EXTINGUISHER
6
.
3
0
m
3.00
4.00
FIRE
EXTINGUISHER
14.14m8.82m
16.88m8.82m
FIRE
EXTINGUISHER
20 KL MS
1.50m
UNDER DRIVE WAY
NS
FILL POINT
20 KL MS
UNDER DRIVE WAY
EARTHING PITIN U/G
P 6 (5) 82 dated 7/8/2001
LONG IN UNDER DRIVEWAY INSTALLATIION2 x 20 KL MS , 1 x 20 KL HSD TANK 2m DIA X 6.75m
APPD BY CCOE VIDE LETTER REF.
1.50m
20 KL HSD
UNDER DRIVE WAY
1.50m
R4.0000m
R4.0000m
DP SWITCH
EMERGENCY STOP
SAND BUCKETS
FIRE EXTINGUISHERS
0.70M WIDE PAVEMENT
SALES ROOM2.46X3.00M
LUBE
2.46X3.00M
D.S.M2.00X3.00M
TOILET 1.78X1.5M
TOILET 1.78X1.39M
ELECTRICAL UTILITY2.5X3.00M
D2
D2
3.46m
6.92m
DD1
D1
8.15m
D1
PANNEL BOARD
ROOM 4.69m
3.96m
2.96m
1.50m
8.8
5m
7
.
1
4
m
2.26m
2.00
MPDMS/HSD2X4X2
SUCT
ION
LINES
LAID
IN T
RENC
H
SUCT
ION
LINES
LAID
IN T
RENC
H
21.5
0m
26.16m
10.9
3m
8.0
0m
8.0
0m
8.48m
10
.57m
17.61m
MPDMS/HSD2X4X2
MPDMS/HSD2X4X2
MPDMS/HSD2X4X2
MPDMS/HSD2X4X2
9
.
4
6
m
ALL ALL PUMP ISLAND( 4 x 2.30 M LENGTH X 1.00M WIDTH X
0.30M HEIGHT ABOVE DRIVEWAY LEVEL)
YARD LIGHTYARD LIGHTYARD LIGHT
ACCOUSTICGENERATOR
EMERGENCY STOP
20 KVA ACCOUSTIC GENERATORFITTED WITH SPARK ARRESTOR
5 NO FIRE EXTINGUSHERS
AIR GAUGE
HOARDING BOARD0.230m WIDTH1.8M HIGH COMPOUND WALL
4 NO SAND BUKETS5 NOS FIRE BUCKETS
EMERGENCY STOP
ATGSTP 0.75 HP
ATGSTP 0.75 HP
ATGSTP 0.75 HPNS
NS
RAIN WATERHARVESTING WELLTRENCH
existing.Building demolished
existing.shed
5.23m
exi.shed demolished
5
.0
0
m
5.00m
7
.
5
0
m
F
O
R
R
O
A
D
W
I
D
E
N
I
N
G
EXISTING.18.28M WIDE ROADPROPOSED.30.00M WIDE ROAD
7.50 m FOR ROAD W
IDENING
5.00m set back line
5.00m
set b
ack lin
e
4
6
.1
7
m
46.88m
2
5
.8
8
m
7
.2
2
m
1
5
.
1
3
m
1
4
.
4
3
m
8
.
5
9
m
6
.
3
6
m
1
.9
6
m
6.86m
1
3
.4
6
m
27.6
8m
14.6
7m
15.73m
17.26m
50.28m
26.2
1m
16.69m
7.9
7m
R
O
A
D
W
I
D
E
N
I
N
G
A
R
E
A
-
1
0
2
6
.
7
9
S
q
m
ROAD WIDENING
AREA-1026.79 Sqm
5
.
0
0
m
RWH PIT
1.0m DIA
RWH PIT
1.0m DIA
0.25
3.85
0.15
3.32
0.25
m3.
70m
0.30
m
ELEVATIONSCALE 1:100
SCALE-N T SNO PROTECTED WORKS LYING WITHIN 100 M RADIUS
LOCATION PLAN
To Karihobanahalli
To G
ango
ndan
a Hall
i
To Herohalli
7.54
9.24
7.00
9.06
6.62
4.73
3.77
4.18
1.20
3.08
2.76
10.1
6
1.79
1.16
5.53
5.63
10.21
7.94
1.76
0.62
2.43
12.05
25.63m
43.39m
2
.1
0
m
1
0
.7
9
m
4
.8
1
m
4.95m
5
.0
2
m
5
.
1
7
m
4
.
6
6
m
1
0
.
0
4
m
1
5
.
0
8
m
P
R
O
P
O
S
E
D
P
E
T
R
O
L
B
P
C
L
B
U
N
K
9
9
6
.
1
2
S
q
m
R
1
0
0
.
0
M
R
1
0
0
.
0
M
R
1
0
0
.
0
M
R
1
0
0
.
0
M
Block Name Block Use Block SubUse Block StructureBlock Land UseCategory
AA (BB) Commercial Small Shop Bldg upto 11.5 mt. Ht. C1
BlockName
Type SubUseArea(Sq.mt.)
Units CarReqd. Prop. Reqd./Unit Reqd. Prop.
AA (BB) Commercial Small Shop > 0 50 509.43 1 10 -Total : - - - - 10 10
Vehicle Type Reqd. AchievedNo. Area (Sq.mt.) No. Area (Sq.mt.)
Car 10 137.50 10 137.50Total Car 10 137.50 10 137.50TwoWheeler - 13.75 0 0.00Other Parking - - - 0.00Total 151.25 137.50
Block No. of Same Bldg Total Built Up Area(Sq.mt.)
Proposed FAR Area(Sq.mt.) Total FAR Area
(Sq.mt.)Commercial
AA (BB) 1 509.43 509.43 509.43Grand Total: 1 509.43 509.43 509.43
Floor Name Total Built Up Area (Sq.mt.)Proposed FAR Area (Sq.mt.)
Total FAR Area (Sq.mt.)Commercial
Ground Floor 509.43 509.43 509.43Total: 509.43 509.43 509.43Total Number of SameBlocks:
1
Total: 509.43 509.43 509.43
BLOCK NAME NAME LENGTH HEIGHT NOSAA (BB) D1 0.76 2.10 02AA (BB) D 1.10 2.10 03
BLOCK NAME NAME LENGTH HEIGHT NOSAA (BB) V 1.00 2.50 02AA (BB) W 1.50 2.50 05
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
N