ENCLOSED AND OPEN STARTERS (up to 75KW)
Enclosed and Open Starters (up to 75KW)
Summary
3Enclosed and Open Starters (up to 75KW)
Enclosed Direct-On-Line Starter 4
Enclosed Direct-On-Line Starter - Accessories 6
Enclosed Star - Delta Starter 7
Open Star - Delta Starter 8
Enclosed Direct-On-Line Starter - Technical Data 9
ENCLOSED AND OPEN STARTERS (up to 75KW)
.co.nzwww.4 Enclosed and Open Starters (up to 75KW)
Enclosed Direct-On-Line Starter
Three-phase D.O.L Starter
• Assembled with thermal overload relay• Short circuit protection has to be ensured by a separate short circuit
protection facility• IP65
Notes: 1) Some motors characteristics may vary according to each manufacturer; 2) Other voltages avaliable; 3) Spare compact contactor for DLW-7 on request.
Maximum rated operational power of three-phase motors 50/60 Hz1)
Setting range ofoverload relay Max. rated
operationalReference Code Contactor3) Overload relay
Weight
230-240 V 400-415 V 500 V 690 V
kW kW kW kW A kgIr (A)
Enclosed direct on-line starters size 02
0.06 0.09 - - 0.28 ... 0.4 0.4 DLW-7P65-R01 CW07 RW17-1D3-D004
0.530
0.090.12 - -
0.4 ... 0.63 0.63 DLW-7P65-R02CW07
RW17-1D3-C0630.18 - - CW07
0.12 0.25 - - 0.56 ... 0.8 0.8 DLW-7P65-R03 CW07 RW17-1D3-D008
0.18 0.37 - - 0.8 ... 1.2 1.2 DLW-7P65-R04 CW07 RW17-1D3-D012
0.25 0.55 - - 1.2 ... 1.8 1.8 DLW-7P65-R05 CW07 RW17-1D3-D018
0.37 0.75 - -1.8 ... 1.8 2.8 DLW-7P65-R06
CW07RW17-1D3-D028
0.55 1.1 - - CW07
0.75 1.5 - - 2.8 ... 4.0 4.0 DLW-7P65-R07 CW07 RW17-1D3-U004
1.1 2.2 - - 4.0 ... 6.3 6.3 DLW-7P65-R08 CW07 RW17-1D3-D063
1.5 3 - - 5.6 ... 8.0 7.0 DLW-7P65-R09 CW07 RW17-1D3-U008
Enclosed direct on-line starters size 04
- - 0.12 0.18 0.28 ... 0.4 0.4 DLW-9P65-R20 CWM9 RW27-1D3-D004
0.804
- - 0.18 0.25 0.4 ... 0.63 0.63 DLW-9P65-R21 CWM9 RW27-1D3-C063
- - 0.25 0.37 0.56 ... 0.8 0.8 DLW-9P65-R22 CWM9 RW27-1D3-D008
- - 0.37 0.550.8 ... 1.2 1.2 DLW-9P65-R23 CWM9 RW27-1D3-D012
- - 0.55 0.75
- - 0.75 1.1 1.2 ... 1.8 1.8 DLW-9P65-R24 CWM9 RW27-1D3-D018
- - 1.1 1.51.8 ... 2.8 2.8 DLW-9P65-R25 CWM9 RW27-1D3-D028
- - 1.5 2.2
- - 2.2 3 2.8 ... 4.0 4.0 DLW-9P65-R26 CWM9 RW27-1D3-U004
- - 3 4 4.0 ... 6.3 6.3 DLW-9P65-R27 CWM9 RW27-1D3-D063
- - 4 5.5 5.6 ... 8.0 8.0 DLW-9P65-R28 CWM9 RW27-1D3-U008
2.2 4 5.5 7.5 7.0 ... 10 9.0 DLW-9P65-R29 CWM9 RW27-1D3-U010
0.815
3.0 5.5 - 9.2 8.0 ... 12.5 12 DLW-12P65-R30 CWM12 RW27-1D3-D125
- - 7.5 11 10 ... 15 15 DLW-18P65-R31 CWM18 RW27-1D3-U015
4.0 7.5 9.2 - 11 ... 17 67 DLW-18P65-R32 CWM18 RW27-1D3-U017
- 9.2 11 15 15 ... 23 18 DLW-18P65-R33 CWM18 RW27-1D3-U023
5.5 11 - 18.5 15 ... 23 23 DLW-25P65-R33 CWM25 RW27-1D3-U0230.860
7.5 - 15 22 22 ... 32 25 DLW-25P65-R34 CWM25 RW27-1D3-U032
Enclosed direct on-line starters size 06
- 15 18.5 - 22 ... 32 32 DLW-32P65-R34 CWM32 RW27-1D3-U0321.270
9.2 - - 30 25 ... 40 32 DLW-32P65-R35 CWM32 RW27-1D3-U040
11 18.5 22 - 25 ... 40 40 DLW-40P65-R35 CWM40 RW27-1D3-U0401.430
- - - 37 32 ... 50 40 DLW-40P65-R37 CWM40 RW27-1D3-U050
Replace by version suffix code (device)
Versions (add sufix code in type)
Device Code
Start - Stop/Reset operation (standard) P
Remote control (without buttons) I
Stop/Reset operation (without ON button) D
Hand/OFF/Auto operation (Hand = local control / Auto = remote control)
B
Replace by code for control voltage
Control voltage 50/60 Hz2) 230 V 240 V 400 V 415 V 500 V
Codes D24 D25 D34 D35 D40
.co.nzwww. 5Enclosed and Open Starters (up to 75KW)
Single-phase D.O.L Starter
• Assembled with thermal overload relay• Short circuit protection has to be ensured by a separate short circuit
protection facility• IP65
Notes: 1) Some motors characteristics may vary according to each manufacturer; 2) Other voltages avaliable; 3) Spare compact contactor for DLW-7 on request.
Maximum rated operational power of three-phase motors 50/60 Hz1)
Setting range ofoverload relay Max. rated
operationalReference Code Contactor3) Overload relay
Weight
230-240 V
kW A kgIr (A)
Enclosed direct-on-line starters size 02
0.25 1.8 ... 2.8 2.8 DLWM-7P65-RM06 CW07 RW17-1D2-D028
0.5300.37 2.8 ... 4 4 DLWM-7P65-RM07 CW07 RW17-1D2-U004
0.55 - 0.75 4 ... 6.3 6.3 DLWM-7P65-RM08 CW07 RW17-1D2-D063
1.1 5.6 ... 8 7 DLWM-7P65-RM09 CW07 RW17-1D2-U008
Maximum rated operational power of three-phase motors 50/60 Hz1)
Setting range ofoverload relay Max. rated
operationalReference Code Contactor3) Overload relay
Weight
230-240 V 480 V
kW kW A kgIr (A)
Enclosed direct-on-line starters size 04
- 0.25 0.8 ... 1.2 1.2 DLWM-9P65-RM23 CWM9 RW27-1D2-D012
0.804
- 0.37 1.2 ... 1.8 1.8 DLWM-9P65-RM24 CWM9 RW27-1D2-D018
- 0.55-0.75 1.8 ... 2.8 2.8 DLWM-9P65-RM25 CWM9 RW27-1D2-D028
- 1.1 2.8 ... 4 4 DLWM-9P65-RM26 CWM9 RW27-1D2-U004
- 1.5 4 ... 6.3 6.3 DLWM-9P65-RM27 CWM9 RW27-1D2-D063
- 2.2 5.6 ... 8 8 DLWM-9P65-RM28 CWM9 RW27-1D2-U008
- 3 7 ... 10 9 DLWM-9P65-RM29 CWM9 RW27-1D2-U010
1.5 3.7 8 ... 12.5 12 DLWM-12P65-RM30 CWM12 RW27-1D2-D125 0.815
2.2 - 10 ... 15 15 DLWM-18P65-RM31 CWM18 RW27-1D2-U015
0.815- - 11 ... 17 17 DLWM-18P65-RM32 CWM18 RW27-1D2-U017
3 - 15 ... 23 18 DLWM-18P65-RM33 CWM18 RW27-1D2-U023
- 5.5 11 ... 17 17 DLWM-25P65-RM32 CWM25 RW27-1D2-U017
0.8603.7 - 15 ... 23 23 DLWM-25P65-RM33 CWM25 RW27-1D2-U023
- - 22 ... 32 25 DLWM-25P65-RM34 CWM25 RW27-1D2-U032
Enclosed direct-on-line starters size 06
- 7.5 15 ... 23 23 DLWM-32P65-RM33 CWM32 RW27-1D2-U0231.270
7.5 - 25 ... 40 32 DLWM-32P65-RM35 CWM32 RW67-1D2-U040
10 - 30 ... 50 40 DLWM-40P65-RM37 CWM40 RW67-1D2-U050 1.430
Replace by version suffix code (device)
Versions (add sufix code in type)
Device Code
Start - Stop/Reset operation (standard) P
Remote control (without buttons) I
Stop/Reset operation (without ON button) D
Hand/OFF/Auto operation (Hand = local control / Auto = remote control)
B
Replace by code for control voltage
Control voltage 50/60 Hz2) 230 V 240 V 400 V 415 V 500 V
Codes D24 D25 D34 D35 D40
.co.nzwww.6 Enclosed and Open Starters (up to 75KW)
Wiring DiagramThree-phase D.O.L. Starter
Figure 1 Figure 2
Enclosed Direct-On-Line Starter - Accessories
Empty Enclosures• IP65 • For housing one CWC07...16, CWM9...40 contactor and one RW overload relay
Illustrative pictures Size Reference code For use with Weight (kg)
Empty enclosure. With ON/OFF operation 02 EB 02P CW07 + RW17 0.200
04 EB 04P CWM9...25 +RW27 0.275
04 EB 04CP CWC07...16 + RW17 0.275
06 EB 06AP CWM32 + RW27 0.390
06 EB 06BP CWM32...40 + RW67-1D 0.390
Empty enclosure. With STOP/RESET operation02 EB 02D CW07 + RW17 0.200
04 EB 04D CWM9...25 +RW27 0.275
04 EB 04CD CWC07...16 +RW17 0.275
06 EB 06AD CWM32 + RW27 0.390
06 EB 06BD CWM32...40 + RW67-1D 0.390
Empty enclosure. With HAND/OFF/AUTO operation 02 EB 02B CW07 + RW17 0.210
04 EB 04B CWM9...25 +RW27 0.285
04 EB 04CB CWC07...16 + RW17 0.285
06 EB 06AB CWM32 + RW27 0.400
06 EB 06BB CWM32...40 + RW67-1D 0.400
Single-Phase D.O.L Starter
Control circuit with phase to phase coil supply
When using 24 V, 48 V, 110 V, etc. on the reference code, WEG D.O.L. starters (DLW) will be factory-connected, as per wiring diagrams of figure 2, that is, with control circuit to be connected through a separate coil supply.
Control circuit with phase to phase coil supply
When using 230 V, 400 V, 500 V, and 690 V on the reference code, WEG D.O.L. starters (DLW) will be factory-connected, as per wiring diagrams of figure 1, that is, with phase to phase coil supply. For the voltages with phase to phase coil supply, contact WEG.
Note: When using remote control, disconnect the circuit at the points marked with the “x” in figures 1 and 2 and connect the external devices (thermostat, pushbutton, etc), as indicated with broken lines.
L1 L2
FT1
2
1
6
5
U1 U2
K12 6
1 5
K1A2
4
3K1
13
14I
M1~
A1
D
FT19595
9696
02
1
L1 L2 L3
FT1
2
1
4 6
3 5
U1
K142 6
1 3 5 4
3K1
13
14I
M3~
V1 W1
D
K1A2
A1
FT19595
9696
02
1
LNL1 L2 L3
FT1
2
1
4 6
3 5
U1
K142 6
1 3 5 4
3K1
13
14I
M3~
V1 W1
D
K1A2
A1
FT19595
9696
02
1
.co.nzwww. 7Enclosed and Open Starters (up to 75KW)
318
mm
360
mm
172 mm
228 mm
250 mm
Ø7 mm(4x)
Notes: 1) Specifications valid only for 50/60 Hz three-phase, 4 poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design; 2) For contactor coil voltage different to the supply voltage, contact WEG.
Dimensions
Enclosed Star - Delta Starter
• Start and Stop pushbuttons using CSW line• Degree of protection IP65• RTW - ET electronic timer with adjustable change over time (3 to 30
seconds)• Standard thermal overload RW, phase-failure sensitivity, tripping class 10,
temperature compensation, auxiliary contacts and Hand/Auto/Reset button• Ample wiring space
Selection GuideSize 10
Maximum rated operational power of three-phase motors 50/60 Hz1)
kW
Main & Deltacontactors
Starcontactor
Overloadrelay
Reference code
Control voltage2)
240 V ac - 50/60 Hz 415 V ac - 50/60 Hz
3...7.5 CWM9 CWM9 RW27 ESDW-7.5D25A65 ESDW-7.5D35A65
11 CWM12 CWM9 RW27 ESDW-11D25A65 ESDW-11D35A65
15 CWM18 CWM12 RW27 ESDW-15D25A65 ESDW-15D35A65
18.5 CWM25 CWM12 RW27 ESDW-18.5D25A65 ESDW-18.5D35A65
22 CWM25 CWM18 RW27 ESDW-22D25A65 ESDW-22D35A65
30 CWM40 CWM18 RW67 ESDW-30D25A65 ESDW-30D35A65
37 CWM40 CWM25 RW67 ESDW-37D25A65 ESDW-37D35A65
45 CWM50 CWM32 RW67 ESDW-45D25A65 ESDW-45D35A65
55 CWM65 CWM32 RW67 ESDW-55D25A65 ESDW-55D35A65
75 CWM80 CWM50 RW67 ESDW-75D25A65 ESDW-75D35A65
WEG can build special starters according to your requirements. Contact your local WEG office or Agent.
Provision for cableStandard
Top Botton
Size 10 3 x Ø28.3 mm or 3 x Ø37 mm 3 x Ø28.3 mm or 3 x Ø37 mm
Rear View Side View Frontal View
.co.nzwww.8 Enclosed and Open Starters (up to 75KW)
338m
m
214mm
254m
m
189mm
RW27D
D
174mm
338m
m
214mm
254m
m
189mm
RW27D
D
174mm
254
mm
338
mm
189 mm
D
174 mm
214 mm
Notes: 1) Specifications valid only for 50/60 Hz three-phase, 4 poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design; 2) For contactor coil voltage different to the supply voltage, contact WEG.
Open Star - Delta Starter
• Standard thermal overload RW, phase-failure sensitivity, tripping class 10, temperature compensation, auxiliary contacts and Hand/Auto/Reset button
• Terminal blocks for start and stop pushbuttons connections• Easy installation• RTW - ET electronic timer with adjustable change over time (3 to 30 seconds)
3...22 kW D=115 mm
30...37 kW D=125 mm
45...75 kW D=155 mm
Selection Guide
Maximum rated operational power of three-phase motors 50/60 Hz1)
kW
Main & Deltacontactors
Starcontactors
Overloadrelay
Reference code
Control voltage2)
240 V ac - 50/60 Hz 415 V ac - 50/60 Hz
3...7.5 CWM9 CWM9 RW27 OSDW-7.5D25A OSDW-7.5D35A
11 CWM12 CWM9 RW27 OSDW-11D25A OSDW-11D35A
15 CWM18 CWM12 RW27 OSDW-15D25A OSDW-15D35A
18.5 CWM25 CWM12 RW27 OSDW-18.5D25A OSDW-18.5D35A
22 CWM25 CWM18 RW27 OSDW-22D25A OSDW-22D35A
30 CWM40 CWM18 RW67 OSDW-30D25A OSDW-30D35A
37 CWM40 CWM25 RW67 OSDW-37D25A OSDW-37D35A
45 CWM50 CWM32 RW67 OSDW-45D25A OSDW-45D35A
55 CWM65 CWM32 RW67 OSDW-55D25A OSDW-55D35A
75 CWM80 CWM50 RW67 OSDW-75D25A OSDW-75D35A
Ø7 mm (4x)
Dimensions
Depths
Frontal View Side View
.co.nzwww. 9Enclosed and Open Starters (up to 75KW)
Enclosed Direct-On-Line Starter - Technical Data
Enclosed Direct-On-Line Starters DLW / DLWM - Dimensions (mm)
Frames 02, 04 and 06
Standard IEC/EN 60947
Operating temperature -20 ºC...55 °C
Storage temperature -50 ºC...80 °C
Degree of protection IP65
Mechanical lifespan (operation) 1 x 106
Electrical lifespan (operation) 1 x 105
Maximum number of operation per hour 15
Enclosure Sizes
Size 02 04 06 08 10
∅A 4.5 4.5 6.5 5 7
B 150 180 205 245 318
C 98 111 126 143 167
D 90 105 120 180 250
E 155 185 210 280 360
F - - - 166 228
Frames 08 and 10
B
F
ØA
C D
DC
E
∅A
E
205
BM
6
Cable Knock-Outs Sizes
Size 02 04 06 08 10
Superior part 2x∅PG16
or 2x∅20 mm
2x∅PG16/21
or 2x∅20/25 mm
2x∅PG21/29
or 2x∅25/32 mm
2x∅PG21/29
or 2x∅25/32 mmInferior part
.co.nzwww.10 Enclosed and Open Starters (up to 75KW)
Notes