Post on 09-Jul-2020
transcript
CATEGORY
030
An air conditioner that is people-friendly is also environment-friendly.
Fujitsu General offers a broad lineup of products from large living rooms to
bedrooms and children’s rooms. We make your room more comfortable with
a wide range of air conditioner types from ceiling wall type with automatic
filters and cleaning functions to wall mounted type that improve the air
cleaning function. Of course these models feature highly efficient operation
that conserves electricity.
Energy saving design to provide a comfortable indoor environment while being environment-friendly.
031
INVERTER SPLIT ALL TYPE LINEUP
INVERTER: Models by Country
For SingaporeFor Vietnam
032
034
INVERTER: Common ModelsWALL MOUNTEDCOMPACT CASSETTECIRCULAR FLOW CASSETTECASSETTEFLOOR/CEILINGCEILINGSLIM DUCTMEDIUM STATIC PRESSURE DUCTHIGH STATIC PRESSURE DUCT
048
FEATURE SUMMARY068
PRODUCT CATEGO
RY - SPLIT
WALL MOUNTED
ARYG18LLTB
COMPACT CASSETTE / CASSETTE
FLOOR / CEILING UNIVERSAL CEILING
HIGH STATIC PRESSURE DUCT
SLIM DUCT MEDIUM STATIC PRESSURE DUCT
Cooling only
Cooling only
Heating & Cooling
Heating & Cooling
Heating & Cooling
ASAG12JLCAASAG09JLCA
AUYG18LVLB
ASAA18JCC
AUXG18LRLB
ABYG18LVTB
INVERTER : Models by Country
WALL MOUNTED
CASSETTE
5.318
4.114
3.512
2.59
Capacity (kW)Model Code
Cooling only
Heating & Cooling
ASYG12LUCA ASYG14LUCAASYG09LUCA
ASAA09JGC ASAA12JGC
ASAG09CPTA-V ASAG12CPTA-V ASAG18CPTA-V
ASAG18JFCB
5.318
4.114
3.512
2.59
5.318
4.114
3.512
2.59
INVERTER : Common ModelsCapacity (kW)Model Code
Cooling only / Heating & Cooling
ASAG12LLTA-V,ASAG12JLTB-V
ASAG09LLTB-V,ASAG09JLTB-V
Heating & Cooling
>> Page 62, 64
Heating & Cooling
>> Page 66
>> Page 58, 60
>> Page 52, 56
>> Page 48
Heating & Cooling
>> Page 54
CIRCULAR FLOW CASSETTE
>> Page 50
>> Page 46
>> Page 44
>> Page 40, 42
>> Page 36, 38
>> Page 34
WALL MOUNTEDfor Vietnam
for Singapore
N E W N E W N E W
Cooling only
032
SPLIT ALL TYPE LINEUPSPLIT ALL TYPEINVERTER
ARYG24LMLA ARAG30LMLA ARAG36LMLAARAG45LMLA
AUYG24LVLA
AUXG24LRLB AUXG30LRLB AUXG36LRLB AUXG45LRLB AUXG54LRLB
AUAG30LRLA
ASAA24JCC ASAA30JCC
AUAG36LRLA AUAG45LRLA AUAG54LRLA
ABYG24LVTA ABAG30LRTA ABAG36LRTA ABAG45LRTA
15.854
13.245
10.536
8.830
7.124
ASAG24JFCB ASAG30JFTB
AUAG24LRLA-A
ASAG24CPTA-V
AUAG36LRLD-A AUAG36LRLC-A AUAG45LRLD-A
15.854
16.560
16.560
13.245
10.536
8.830
7.124
15.854
16.560
13.245
10.536
8.830
7.124
ARYG45LHTA ARYG54LHTA ARYG60LHTA
033
CATEGORY -
034
Thin & Slim design
Specifications
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
Heating(Min-Max)
Cooling/HeatingInput Power
Power SourceCooling
(Min-Max)
Cooling
IndoorOutdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/hkW
BTU/h
Model No.Indoor unit
Outdoor unit
ASYG09LUCA
AOYG09LUCB
230/1/502.5(0.5-3.2)
8,500(1,700-10,900)3.2(0.5-4.2)
10,900(1,700-14,300)0.555/0.680
4.504.71
3.1/3.41.3
42/4248/48
800/8001,720/1,510
282x870x1859.5(21)
540x660x29025.0(55)6.35/9.52
11.8 / 15.0 to 16.820(15)
15-10 to 43-15 to 24
R410A
ASYG12LUCA
AOYG12LUC
230/1/503.5(0.9-4.0)
11,900(3,100-13,600)4.0(0.9-5.6)
13,600(3,100-19,100)0.905/0.930
3.874.30
4.6/4.71.8
43/4350/50
850/8501,940/1,700
282x870x1859.5(21)
540x790x29033.0(73)6.35/9.52
11.8 / 15.0 to 16.820(15)
15-10 to 43-15 to 24
R410A
ASYG14LUCA
AOYG14LUC
230/1/504.2(0.9-5.0)
14,300(3,100-17,100)5.4(0.9-6.0)
18,400(3,100-20,500)1.235/1.380
3.403.91
5.8/6.3 2.1
45/4550/50
900/9001,940/1,700 282x870x185
9.5(21)540x790x290
34.0(75)6.35/12.70
11.8 / 15.0 to 16.820(15)
15-10 to 43-15 to 24
R410A
Thin and slim design is realized by Ø5mm heat exchanger and high efficiency wind blower. Big open panel and High density multi path heat exchanger
Ø5 mm
20 mm
H282 X W870 X D185
Large fan
Open panel
Distributor 4-path
RefrigerantLarge intake
185 mm
Model : ASYG09LUCA / ASYG12LUCA / ASYG14LUCA
AOYG09LUCB
Wireless remotecontroller (R.C.)
AOYG12LUCAOYG14LUC
WALL MOUNTEDINVERTER
035
Dimensions Models: (Unit : mm)ASYG09LUCA / ASYG12LUCA / ASYG14LUCA
Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week. For other modes, program timer and sleep timer can be also selected by one push.
3 Mode timer(Weekly/Program/Sleep)
282
870 185
337
55
100
or m
ore
Powerful operation20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.
Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.
Noise
Ratednoise level
3 dBDown
Low noisemode
Powerful
Setting temp.
Normal mode
Time
Tem
pera
ture
Economy operationSetting temp. is shifted by 1°C automatically.
Ex. : Cooling operation
Tem
p. Economy operation
Normal operation Time
Set temperature
Optional parts
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTY-TERX
UTY-TFNXZ3
UTY-TWBXF, UTY-TWBXF2
UTY-VTGX
UTY-VTGXV
UTY-XWZXZ5
Wired Remote Controller:
Simple Remote Controller (3-wire type):
External Switch Controller:
Wireless LAN Adaptor:
Communication Kit:
Network Convertor for single split:(DC power supply type)
Network Convertor for single split:(AC power supply type)
External Connect Kit:
Wide operation range50
40
30
20
10
0
-10
-20 -15°C
Cooling
24°CHeating
-10°C
43°C
Shift setting temp
PRODUCT CATEGO
RY - SPLIT
For Singaporee
036
Specifications
Capacity
EERRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling)
Sound Pressure Level(Cooling)
Piping Connections (Small / Large)
Max Height DifferenceOperation Range Cooling
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
CoolingInput Power
Power SourceCooling
(Min-Max)
Cooling
Indoor (High)OutdoorIndoor
Outdoor
Cooling
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
AW/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/h
Model No.Indoor unit
Outdoor unit
ASAA09JGC
AOAR09JGC
ASAA12JGC
AOAR12JGC
Net Dimension H x W x DNet Weight
Super Quiet Operation
Top class low noise operation by new airflow construction. Our quiet operation makes the more comfortable environment in a bed room and a study room, etc.
High Efficient Compact Design
Compact design is realized by high density multi-path heat exchanger.
Volume reduction of heat
exchanger: 30 %
Making the tube thin:
7 mm 5 mm
Even temperature
Improved the heatexchanger effectiveness
QuietFan speed
22 dB(A) Noise level
Model : ASAA09JGC / ASAA12JGC
230/1/502.5(0.5-3.2)
8,500(1,700-10,900)0.703.573.51.3 4348
7501,870
260x790x1987.5 (17)
540x660x29028.0 (62)6.35/9.52
11.8/15.0 to 16.815(10)
1018 to 46R410A
230/1/503.5(0.9-4.0)
11,900(3,100-13,600)1.033.404.91.84349 750
1,830260x790x198
7.5 (17)540x660x290
30.0 (66)6.35/9.52
11.8/15.0 to 16.820(15)
1518 to 46R410A
AOAR09JGCAOAR12JGC
Wireless R.C.
WALL MOUNTEDINVERTER
037
Dimensions Models: (Unit : mm)ASAA09JGC / ASAA12JGC
198790
260
Easy maintenance
Removable & washable panel
Using different filters at both sides
Ion Deodorization Filter
Apple-catechin Filter
Pre Filter
Organic coatingfin used heat exchanger
Antibacterial deodorizing pre-filter with special ceramic powder
Air conditioner filter features
Air conditioner filter features
Ion Deodorization Filter
Apple-catechin Filter
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
The Apple-catechin filter uses static electricity to clean fine particles and dust in the air.
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Sub Interface Board:
External Connect Kit:
UTY-RNNYM
UTY-RSNYM
UTY-XCBXE
UTY-XWZX
PRODUCT CATEGO
RY - SPLIT
For Singaporee
038
Specifications
Capacity
EERRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling)
Sound Pressure Level(Cooling)
Piping Connections (Small / Large)
Max Height DifferenceOperation Range Cooling
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
CoolingInput Power
Power SourceCooling
(Min-Max)
Cooling
Indoor (High)OutdoorIndoor
Outdoor
Cooling
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
AW/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/h
Model No.Indoor unit
Outdoor unit
Net Dimension H x W x DNet Weight
High Energy Efficiency
Model : ASAG18JFCB / ASAG24JFCB / ASAG30JFTB
(18/24)
ASAG18JFCB
AOAG18JFCB
230/1/505.2(0.9-8.0)
17,700(3,100-27,300)1.333.916.01.04953
1,1201,910
320x998x23814 (31)
620x790x29041 (90)
6.35/15.8812.0/16.030 (15)
20-10 to 46
R410A
ASAG30JFTB
AOAG30JFTB
230/1/507.3(2.9-9.0)
24,900(9,900-30,700)1.963.728.41.9 5052
1,3803,600
340x1,150x28018 (40)
820x900x33061 (134)
9.52/15.8813.8 / 15.8 to 16.7
50 (20)30
-15 to 46R410A
ASAG24JFCB
AOAG24JFCB
230/1/506.0(0.9-8.0)
20,400(3,100-27,300)1.583.807.11.14955
1,1202,460
320x998x23814 (31)
620x790x29041 (90)
6.35/15.8812.0/16.030 (15)
20-10 to 46
R410A
AOAG18/24JFCB AOAG30JFTB
ASAG18JFCBASAG24JFCB
ASAG30JFTB
Wireless R.C.
3.80
NEW
3.80
NEW
3.91
NEW
WALL MOUNTEDINVERTER
039
Dimensions (Unit : mm)
Models: ASAG30JFTB
998
1150
238
280
320
340
Comfort airflow
Optional parts
Wired Remote Controller:
Simple Remote Controller (3-wire type):
Wireless LAN Adaptor:
Communication kit:
External Connect Kit:
UTY-RNNYM
UTY-RSNYM
UTY-TFNXZ3
UTY-XWNX
UTY-XWZX
Power diffuser"Horizontal airflow" does not blow cool air directly at the occupants in the room
Large Capacity & Powerful airflow
Achieved large capacity and powerful airflow by large heat exchanger, long cross-flow fan, high output DC fan motor and new airflow structure design.
Power diffuser
(18/24model only)
( C)
15 16 17 18
Outside air conditions: 35 C 40% Operation contents: Cooling, Set temperature (Min set temp) 18 C, airflow Hi, Air direction downward and front
Airflow23 % UP!
(30 model only)
New dual suction design
Models: ASAG18JFCB/ASAG24JFCB
Large heat exchanger
Long cross-flow fan and High output DC fan motor
Airflow23 % UP!
(30 model only)
Wide operation range
50
40
30
20
10
0
-10
Cooling
-10°C
46°C
PRODUCT CATEGO
RY - SPLIT
For Singaporee
040
Specifications
Model : AUAG24LRLA-A / AUAG36LRLC-A
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation Range
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
RefrigerantCassette Grille
Input Power
Power Source
CoolingHeating
Heating(Min-Max)
Cooling/Heating
Cooling(Min-Max)
Cooling
Indoor (High)Outdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor / grille
Outdoor unit
°CDB
mm
m
mm
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
Model No.Indoor unit
Outdoor unit
AUAG24LRLA-A
AOAG24LBTA-A
230/1/507.10(2.80-10.00)
24,200(9,500-34,100)8.00(2.70-11.20)
27,300(9,200-38,200)1.84/1.86
3.864.30
8.1/8.22.1
40/4051/53
1,600/1,6003,600/3,600
288x840x840 / 50x950x95023.0(51) / 5.5(12)830 x 900 x 330
61.0(134)9.52/15.88
25/3250 (20)
30-15 to 46-15 to 24
R410AUTG-UGYA-W
AUAG36LRLC-A
AOAG36LBTB-A
230/1/5010.00(4.00-14.00)
34,100(13,700-47,800)11.20(4.20-16.20)
38,200(14,300-55,300)2.70/2.60
3.704.31
11.8/11.43.6
46/4653/53
1,900/1,9006,200/5,800
288x840x840 / 50x950x95026.0(57) / 5.5(12)1,260 x 900 x 330
86.0(190)9.52/15.88
25/3250 (20)
30-15 to 46 -15 to 24
R410AUTG-UGYA-W
Top Class High EER
The EER figures in this two models can be found in tick 3 in 24 Btu model and tick 2 in 36 Btu model in the energy-saving program in Singapore.
Long-Reach And Wide Angle Air Flow
The airflow can be travelled in all directions and at far distance. It enables to produce the best performance in sizable spaces such as office and school.
3Side view
Airflow range of 2m / s
[m]
[m]
7 75 53 3
1.5120°
*Weighted COP=0.4xCOP100%+0.6xCOP50%
24 36 Class
CoolingCOP
3.86
4.54
3.70
4.51
: Rated COP: Weighted COP*
kWBtu/h
kWBtu/h
kW
kg(lbs)
kg(lbs)
AOAG24LBTA-A AOAG36LBTB-A
Wired remotecontroller (R.C.)
CASSETTEINVERTER
796(Bolt pitch)
041
Top view
358
9813
3
118
158
288
Drain pipe
Liquid pipe
Side viewGas pipe
338
278
950
950
Bottom view
890(
Ceili
ng o
peni
ngs)
699(
Bolt
pitc
h)
842(indoor unit)
Dimensions (Unit : mm)AUAG24LRLA-A / AUAG36LRLC-A
Economy operation automatically increases the temperature setting by
1 degree which helps to save power consumption.Wired and wireless remote controllers can be simultaneously used, which enables to utilize the benefits of both remote controllers.
Tem
p.
Time
Set temperature
Long piping and operability in high ambient temperature enables to enhance the installation flexibility.
Max pipe length
50 m 30 m
Max height difference
Cooling
46°CMax.
Wired Remote Controller:
Simple Remote Controller (3-wire type):
External Connect Kit:
Wide Panel:
Panel Spacer:
Cassette Grille:
Air Outlet Shutter Plate:
IR Receiver Unit:
External Connect Kit:
Insulation Kit For High Humidity:
Fresh Air Intake Kit:
External Connect Kit:
UTY-RNNYM
UTY-RSNYM
UTD-ECS5A
UTG-AGYA-W
UTG-BGYA-W
UTG-UGYA-W
UTR-YDZC
UTY-LRHYA2
UTY-XWZX
UTZ-KXGA
UTZ-VXGA
UTY-XWZXZ3 (For AOAG36LBTB-A)
CATEGORY -
042
Specifications
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation Range
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
RefrigerantCassette Grille
Input Power
Power Source
CoolingHeating
Heating(Min-Max)
Cooling/Heating
Cooling(Min-Max)
Cooling
Indoor (High)Outdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor / grille
Outdoor unit
°CDB
mm
m
mm
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
Model No.Indoor unit
Outdoor unit
AUAG36LRLD-A
AOAG36LBTC-A
230/1/509.70(4.00-13.50)
33,100(13,600-46,100)10.8(4.20-15.70)
38,200(14,300-53,600)2.56/2.45
3.794.41
11.2 / 10.92.00
46/4653/53
2,000/2,0006,200/5,800
288×840×840 / 53×950×95029.0(63.9)/6.0(13)
1,290×900×33086.0(190)
9.52 / 15.8825 / 3250 (20)
30-15 to 46 -15 to 24
R410AUTG-UKAASW
AUAG45LRLD-A
AOAG45LBTC-A
230/1/5011.70(4.00-14.00)
40,000(13,600-47,800)14.0(4.20-16.20)
47,800(14,300-55,300)3.50/3.73
3.343.75
15.5 / 16.53.50
46/4655/55
2,000/2,0006,750/6,200
288×840×840 / 53×950×95029.0(64)/6.0(13)1,290×900×330
86.0(190)9.52 / 15.88
25 / 3250 (20)
30-15 to 46 -15 to 24
R410AUTG-UKAASW
Uniform air distribution by the seamless air opening
In new model, the gaps between each airflow openings are removed, which enables to distribute wider and uniform airflow to room.
kWBtu/h
kWBtu/h
kW
kg(lbs)
kg(lbs)
Model : AUAG36LRLD-A / AUAG45LRLD-A
AOAG36LBTC-AAOAG45LBTC-A
Wireless R.C.
Achieve a comfortable air conditioning spread to every corner of the room by circular flow & wide vertical airflow.
Comfortable!
In new model, the gaps between each airflow opwhich enables to distribute wider and uniform a
Ø7mm high density heat exchanger
New DC fan motor
High efficient turbo fan
Seamless airflow louver
INVERTER CASSETTEINVERTER
043
Dimensions Models: (Unit : mm)AUAG36LRLD-A / AUAG45LRLD-A
Human Sensor for Energy Saving (Option)
Wireless remote control
High energy efficiency
36 models
EER
3
2
New
45 models
EER
2
1
New
2 modes can be selected.
Auto saving
Auto OFF
Optional parts
Human sensor (Option)
840:
Indo
or u
nit
860
to 9
10
Ceili
ng o
peni
ngs
Ceiling
(Control) box Drain hose
Liquid pipeWire hole
Gas pipe
950
950
IR receiver (Option)
298
(256
)
38
PRODUCT CATEGO
RY - SPLIT
For Singaporee
044
Powerful Cooling
New system development expands the outdoor temperature upper limit from 46°C to 52°C. Provides a cool and comfortable environment even at 52°C.
Model : ASAG09CPTA-V / ASAG12CPTA-V / ASAG18CPTA-V / ASAG24CPTA-V
AOAG09CPTA-VAOAG12CPTA-VAOAG18CPTA-V
Wireless R.C.
(09/12/18) (24)
ASAG18CPTA-VASAG09/12CPTA-V
ASAG24CPTA-V
AOAG24CPTA-V
Specifications
Capacity
EERCSPFRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling)
Sound Pressure Level(Cooling)
Piping Connections (Small / Large)
Max Height Difference
Operation RangeIndoor
Outdoor
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
CoolingInput Power
Power SourceCooling
(Min-Max)
CoolingCooling
Indoor (High)OutdoorIndoor
Outdoor
Cooling
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/h
Model No.Indoor unit
Outdoor unit
Net Dimension H x W x DNet Weight
ASAG09CPTA-V
AOAG09CPTA-V
220/1/502.70(0.7-2.9)
9,200(2,400-9,900)0.813.334.684.21.04350
5501,910
270×784×2248.5(19)
541×663×29022.0(49)6.35/9.52
11.8/15.0 to 16.820(10)
1518 to 3218 to 52
R32
ASAG12CPTA-V
AOAG12CPTA-V
220/1/503.37(0.8-3.5)
11,500(2,900-12,100)1.182.864.625.91.54350
5501,910
270×784×2248.5(19)
541×663×29022.0(49)6.35/9.52
11.8/15.0 to 16.820(10)
1518 to 3218 to 52
R32
ASAG18CPTA-V
AOAG18CPTA-V
220/1/505.28(1.3-5.4)
18,000(4,500-18,400)1.882.814.638.81.94951
9401,660
270×834×23911.0(24)
541×663×29027.0(60)
6.35/12.7013.8 /15.8 to 16.7
20(10)15
18 to 3218 to 52
R32
ASAG24CPTA-V
AOAG24CPTA-V
220/1/507.04(1.8-7.0)
24,000(6,000-24,000)2.392.955.6411.12.75053
1,1602,885
280 × 980 × 24012.5(28)
632 × 799 × 29036.0(79)
6.35/12.7013.8 /15.8 to 16.7
25(15)20
18 to 3218 to 52
R32
Outdoor Temperature
Indo
or T
empe
ratu
re
32°C
New ModelExpansion operating area
18°C
18°C 46°C 52°C
Current NEW
AOAG24CPTA VAOAG09CPTA-V
WALL MOUNTEDINVERTER
N E W
(24) (24)
045
DimensionsModel:
(Unit : mm)
ASAG09CPTA-V / ASAG12CPTA-V
Model: ASAG24CPTA-V
Model: ASAG18CPTA-V
This model is ranked 5-Star in the energy labeling program in Vietnam.
5-Star Rank in Energy Saving ProgramPM 2.5 filter the newly adoptedClean the air firmly catch the particles of 0.3 ~ 2.5 m.*PM 2.5 is a general term for micro particulate matter less than 2.5 m.
High Reliability System (HRS)
The newly developed general PCB designed with a withstand spike voltage up to 450 V. The design is highly robust.
Catch a lot of dustby the pleat shape
PRODUCT CATEGO
RY - SPLIT
For Vietnam
R32 refrigerant is highly environmentally friendly for the reduction of the global warming potential than another refrigerant.
Adopting new refrigerant R32
980 240
280
784 224
270
834 239
270
*:09/12/18 models
ASAG09CPTA-V
AOAG09CPTA-V
2,70 9.200
4,92
TCVN 7830: 2015
046
Specifications
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
Heating(Min-Max)
Cooling/HeatingInput Power
Power SourceCooling
(Min-Max)
Cooling
IndoorOutdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/hkW
BTU/h
Model No.Indoor unit
Outdoor unit
ASAG09LLTB-V
AOAG09LLTB-V
220/1/502.50(0.9-3.0)
8,500(3,070-10,230)3.00(0.9-3.8)
10,200(3,070-12,960)0.72/0.74
3.474.05
3.6/3.61.3
43/4347/48
720/7401,670/1,470
262x820x2067.0 (15)
540x660x29025.0 (55)6.35/9.52
11.8/15.0 to 16.820(15)
1518 to 46-15 to 24
R410A
ASAG12LLTA-V
AOAG12LLTA-V
220/1/503.40(0.9-3.8)
11,600(3,070-12,960)4.00(0.9-5.0)
13,600(3,070-17,060)1.10/1.13
3.213.54
5.3/5.51.8
43/4350/51
720/7401,830/1,600
262x820x2067.0 (15)
540x660x29028.0 (62)6.35/9.52
11.8/15.0 to 16.820(15)
1518 to 46-15 to 24
R410A
(12)
Model : ASAG09LLTB-V / ASAG12LLTA-V / ASAG09JLTB-V / ASAG12JLTB-V
High EfficientCompact Design
Compact design is realized by high density multi-path heat exchanger.
Wireless R.C.
AOAG09LLTB-VAOAG12LLTA-V
AOAG09/12JLTB-V
ASAG09JLTB-V
AOAG09JLTB-V
220/1/502.50(0.9-3.0)
8,500(3,070-10,230)——
0.72/—3.47
—3.6/—1.3
43/—47/—
720/—1,670/—
262x820x2067.0 (15)
540x660x29025.0 (55)6.35/9.52
11.8/15.0 to 16.820(15)
1518 to 46
—R410A
ASAG12JLTB-V
AOAG12JLTB-V
220/1/503.40(0.9-3.8)
11,600(3,070-12,960)——
1.06/—3.21
—5.3/—1.8
43/—50/—
720/—1,830/—
262x820x2067.0 (15)
540x660x29028.0 (62)6.35/9.52
11.8/15.0 to 16.820(15)
1518 to 46
—R410A
Volume reduction of heat
exchanger: 30 %
Making the tube thin:
7 mm 5 mm
Even temperature
Improved the heatexchanger effectiveness
WALL MOUNTEDINVERTER
047
Dimensions Models: (Unit : mm)ASAG09LLTB-V / ASAG12LLTA-V / ASAG09JLTB-V / ASAG12JLTB-V
820 206
262
Easy maintenance
Removable & washable panel
More Convenient Timer
You can set an integrated ON-OFF or OFF-ON timer suitable for your life style.(Setting time: 0.5, 1, 1.5, 2, 2.5, -----9.5, 10, 11, 12 hours)
From sleep to wake upFrom wake up to go to work
OFF10hours
ON 7hours
12
6
9 3
PM11:00 set
12
6 ON
9hours
OFF2hours
9 3
Ex. : Cooling operation
Optional parts
Remote Controller Holder Kit: UTZ-RXLA
Powerful operationReach the setting temperature quickly.
Super Quiet OperationTop class low noise operation by new airflow construction. Our quiet operation makes the more comfortable environment in a bed room and a study room, etc.
Powerful
Setting temp.
Normal mode
Time
Tem
pera
ture
Economy operationSetting temp. is shifted by 1°C automatically.
Ex. : Cooling operation
Tem
p. Economy operation
Normal operation Time
Set temperature
Shift setting temp
QuietFan speed
22 dB(A) Noise level
PM9:00set
PRODUCT CATEGO
RY - SPLIT
For Vietnam
048
Specifications
Model : ASAG09JLCA / ASAG12JLCA
Capacity
EERRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling)
Sound Pressure Level(Cooling)
Piping Connections (Small / Large)
Max Height DifferenceOperation Range Cooling
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
CoolingInput Power
Power SourceCooling
(Min-Max)
Cooling
Indoor (High)OutdoorIndoor
Outdoor
Cooling
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
AW/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/h
Model No.Indoor unit
Outdoor unit
ASAG09JLCA
AOAG09JLCA
ASAG12JLCA
AOAG12JLCA
Net Dimension H x W x DNet Weight
230/1/502.5(0.9-2.9)
8,500(3,070-9,700)0.733.423.81.34348
7201,710
262x820x2067.0 (15)
535x663x29324.0 (53)6.35/9.52
11.8/15.0 to 16.815(10)
1018 to 46R410A
230/1/503.5(0.9-3.8)
11,900(3,070-12,800)1.0953.205.11.84352
7201,850
262x820x2067.0 (15)
535x663x29326.0 (57)6.35/9.52
11.8/15.0 to 16.815(10)
1018 to 46R410A
AOAG09JLCAAOAG12JLCA
Wireless R.C.
High EfficientCompact Design
Compact design is realized by high density multi-path heat exchanger.
Volume reduction of heat
exchanger: 30 %
Making the tube thin:
7 mm 5 mm
Even temperature
Improved the heatexchanger effectiveness
WALL MOUNTEDINVERTER
049
Dimensions (Unit : mm)ASAG09JLCA / ASAG12JLCA
820 206
262
Removable & washable panel
You can set an integrated ON-OFF or OFF-ON timer suitable for your life style.(Setting time: 0.5, 1, 1.5, 2, 2.5, -----9.5, 10, 11, 12 hours)
From sleep to wake upFrom wake up to go to work
10hours
12
6
9 3
PM11:00 set
12
6
2hours
9 3
Reach the setting temperature quickly.
Top class low noise operation by new airflow construction. Our quiet operation makes the more comfortable environment in a bed room and a study room, etc.
Time
Tem
pera
ture
Setting temp. is shifted by 1°C automatically.
Tem
p.
Time
Set temperature
QuietFan speed
22 dB(A)
PM9:00set
Protective Net Kit: UTZ-NXCA
CATEGORY -
050
Specifications
Model : ASAA18JCC / ASAA24JCC / ASAA30JCC
Power diffuser
( C)
15 16 17 18
Outside air conditions: 35 C 40% Operation contents: Cooling, Set temperature (Min set temp) 18 C, airflow Hi, Air direction downward and front
“Horizontal airflow” does not blow cool air directly at the occupants in the room
Comfort airflow
Power diffuser
Capacity
EERRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling)
Sound Pressure Level(Cooling)
Piping Connections (Small / Large)
Max Height DifferenceOperation Range Cooling
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
CoolingInput Power
Power SourceCooling
(Min-Max)
Cooling
Indoor (High)OutdoorIndoor
Outdoor
Cooling
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
AW/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/h
Model No.Indoor unit
Outdoor unit
ASAA18JCC
AOAR18JCC
ASAA24JCC
AOAR24JCC
ASAA30JCC
AOAR30JCT
Net Dimension H x W x DNet Weight
230/1/505.2(0.9-6.0)
17,700(3,100-20,400) 1.48 3.51 6.62.84350
9002,070
320x998x22814.0 (31)
620x790x29840.0 (88)6.35/12.7
12/1630(15)
2018 to 46R410A
230/1/507.1(0.9-8.0)
24,200(3,100-27,300) 2.45 2.90 10.83.04756
1,1002,640
320x998x22814.0 (31)
620x790x29840.0 (88)
6.35/15.8812/16
30(15)20
18 to 46R410A
230/1/508.0(2.9-9.0)
27,300(9,900-30,700)2.663.01 11.73.04953
1,1003,600
320x998x22814.0 (31)
830x900x33058.0 (128)9.52/15.88
12/1630(20)
2018 to 46R410A
AOAR30JCTAOAR18JCCAOAR24JCC
Wireless R.C.
WALL MOUNTEDINVERTER
051
SPLIT / INVERTER
Dimensions Models: (Unit : mm)ASAA18JCC / ASAA24JCC / ASAA30JCC
998 228
320
Easy maintenance
Simplification of drain pan cleaning improves maintenance-ability.
Using different filters at both sides
Ion Deodorization Filter
Apple-catechin Filter
Pre Filter
Organic coatingfin used heat exchanger
Antibacterial deodorizing pre-filter with special ceramic powder
Air conditioner filter features
Air conditioner filter features
Ion Deodorization Filter
Apple-catechin Filter
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
The Apple-catechin filter uses static electricity to clean fine particles and dust in the air.
Optional parts
Wired Remote Controller:
External Connect Kit:
UTB-YUD
UTY-XWZX
PRODUCT CATEGO
RY - SPLIT
052
Specifications
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation Range
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
Cassette Grille
Input Power
Power Source
CoolingHeating
Heating(Min-Max)
Cooling/Heating
Cooling(Min-Max)
Cooling
Indoor (High)Outdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor / grille
Outdoor unit
°CDB
mm
m
mm
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
Model No.Indoor unit
Outdoor unit
AUXG18LRLB
AOYG18LBCA
230/1/505.2(0.9-6.5)
17,700(3,100-22,200)6.0(0.9-8.0)
20,500(3,100-27,300)1.42 / 1.50
3.664.00
6.2 / 6.62.2
33/3351/50
1,050/1,0501,900/1,700
24 (53) / 6.0 (13)620x790x290
41 (90)6.35/12.7
25/3230 (15)
20-15 to 46-15 to 24
R410A
AUXG24LRLB
AOYG24LBCA
230/1/506.8(0.9-8.0)
23,200(3,100-27,300)7.8(0.9-9.1)
26,600(3,100-31,000)2.16 / 2.18
3.153.58
9.5 / 9.62.7
35/3555/56
1,150/1,1502,460/2,340
24 (53) / 6.0 (13)620x790x290
41 (90)6.35/15.88
25/3230 (15)
20-15 to 46-15 to 24
R410A
AUXG30LRLB
AOYG30LBTA
230/1/508.5(2.8-10.0)
29,000(9,500-34,100)10.0(2.7-11.2)
34,100(9,200-38,200)2.56 / 2.77
3.323.61
11.2 / 12.22.5
40/4053/55
1,600/1,6003,600/3,600
26 (57) / 6.0 (13)830x900x330
61 (134)9.52/15.88
25/3250 (20)
30-15 to 46-15 to 24
R410AUTG-UKYA-W: White Color with touch panel wired remote controller
UTG-UKYC-W: White Color / UTG-UKYA-B*1: Black Color
*1: IR Receiver kit and human sensor kit cannot be connected
AUXG36LRLB
AOYG36LBTA
230/1/509.5(2.8-11.2)
32,400(9,500-38,200)10.8(2.7-12.7)
36,900(9,200-43,300)2.96 / 2.91
3.213.71
13.0 / 12.73.3
44/4454/55
1,900/1,9003,800/3,800
26 (57) / 6.0 (13)830x900x330
61 (134)9.52/15.88
25/3250(20)
30-15 to 46-15 to 24
R410A
AUXG45LRLB
AOYG45LBTA
230/1/5012.5(4.0-14.0)
42,700(13,700-47,800)14.0(4.2-16.2)
47,800(14,300-55,300)3.85 / 3.73
3.253.75
16.8 / 16.34.5
46/4655/55
2,000/2,0006,750/6,200
29 (64) / 6.0 (13)1,290x900x330
86 (190)9.52/15.88
25/3250(20)
30-15 to 46-15 to 24
R410A
AUXG54LRLB
AOYG54LBTA
230/1/5013.3(4.5-14.5)
45,400(21,200-49,500)15.8(4.7-16.5)
53,900(16,000-56,300)4.38 / 4.58
3.043.45
19.1 / 20.05.0
47/4755/57
2,100/2,1006,750/6,850
29 (64) / 6.0 (13)1,290x900x330
86 (190)9.52/15.88
25/3250(20)
30-15 to 46-15 to 24
R410A
Uniform air distribution by the seamless air opening
In new model, the gaps between each airflow openings are removed, which enables to distribute wider and uniform airflow to room.
kWBtu/h
kWBtu/h
kW
kg(lbs)
kg(lbs)
Model : AUXG18LRLB / AUXG24LRLB AUXG30LRLB / AUXG36LRLB / AUXG45LRLB / AUXG54LRLB
AOYG45LBTAAOYG54LBTA
AOYG18LBCAAOYG24LBCA
AUXG18/24LRLB
(Black panel) (Black panel)
AOYG30LBTAAOYG36LBTA
Achieve a comfortable air conditioning spread to every corner of the room by circular flow & wide vertical airflow.
Comfortable!
In new model, the gaps between each airflow opwhich enables to distribute wider and uniform a
Ø7mm high density heat exchanger
New DC fan motor
High efficient turbo fan
Seamless airflow louver
Touch Panel Wired R.C.
246x840x840/53x950x950 288x840x840/53x950x950
AUXG30/36/45/54LRLB
INVERTER CIRCULAR FLOW CASSETTEINVERTER
053
Dimensions Models: (Unit : mm)
( ):AUXG18/24LRLB
AUXG18LRLB / AUXG24LRLBAUXG30LRLB / AUXG36LRLB / AUXG45LRLB / AUXG54LRLB
Various Cassette GrilleBoth black and white color grilles are available. There are three types, white color grille with Remote Controller, only white color grille and only black color grille. Possible to choose according to the atmosphere and the use of the room.
Individual louver controlEach louver can be set individually by Touch Panel Wired Remote Controller to enjoy the comfort of different directional airflows according to various room layouts.
Optional parts
Compact Wired Remote Controller:
Wired Remote Controller:
Wired Remote Controller (Touch Panel):
Simple Remote Controller (3-wire type):
Simple Remote Controller (2-wire type):
Simple Remote Controller (2-wire type):(Without operation mode):
Human Sensor Kit:
External Switch Controller:
Wireless LAN Adaptor:
KNX® Convertor:
MODBUS® Convertor:
Network Convertor for single split:(DC power supply type)
Network Convertor for single split:(AC power supply type)
External input and output PCB:
External Connect Kit:
Insulation Kit For High Humidity:
Fresh Air Intake Kit:
External input and output PCB Box:
Wide Panel:
Panel Spacer:
Cassette Grille:
Air Outlet Shutter Plate:
IR Receiver Unit:
External Connect Kit:
UTY-RCRYZ1
UTY-RLRY, UTY-RVNYM
UTY-RNNYM
UTY-RNRYZ3
UTY-RSNYM
UTY-RSRY
UTY-RHRY
UTY-SHZXC
UTY-TERX
UTY-TFNXZ3
UTY-VKSX
UTY-VMSX
UTY-VTGX
UTY-VTGXV
UTY-XCSX
UTY-XWZXZG
UTZ-KXRA
UTZ-VXRA
UTZ-GXRA
UTG-AKXA-W
UTG-BKXA-W
UTG-UKYA-B, UTG-UKYA-W
UTG-UKYC-W
UTR-YDZK
UTY-LBTYC
UTY-XWZXZ3 (45/54)
*Touch Panel Wired RC (UTY-RNRYZ3)only
Human Sensor for Energy Saving (Option)
*Touch Panel Wired RC (UTY-RNRYZ3) only
2 modes can be selected.
Power is saved whileno one is around
Operation is stoppedwhile no one is around
Auto saving
Auto OFF
Comfortable air conditioning by preventing direct blowing of cold air and by providing swinging air flow simultaneously.
Efficient air conditioning based on the room layout
UTG-UKYA-WWhite Color GrilleWith touch panel wired remote controller
Human sensor (Option)
840:
Indo
or u
nit
860
to 9
10
Ceili
ng o
peni
ngs
Ceiling
(Control) box Drain hose
Liquid pipeWire hole
Gas pipe
950
950
IR receiver (Option)
298
(256
)
38
PRODUCT CATEGO
RY - SPLIT
054
Specifications
2-stage turbo fanHigh efficiency design by 2 stage structure
Model : AUYG18LVLB / AUYG24LVLA
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
RefrigerantCassette Grille
Heating(Min-Max)
Cooling/HeatingInput Power
Power SourceCooling
(Min-Max)
Cooling
IndoorOutdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor / Grille
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/hkW
BTU/h
Model No.Indoor unit
Outdoor unit
AUYG18LVLB
AOYG18LBCB
230/1/505.20(0.9-5.9)
17,700(3,100-20,100)6.00(0.9-7.5)
20,500(3,100-25,600)1.62/1.66
3.213.61
11.5-13.52.2
38/4350/50
680/8002,380/2,080
245×570×570/49×700×70015.0 (33) / 2.6 (6)
632×799×29036 (79)
6.35/12.7025/32
25 (15)15
-10 to 46-15 to 24
R410AUTG-UFYD-W
AUYG24LVLA
AOYG24LBCB
230/1/506.80(0.9-8.0)
23,200(3,100-27,300)8.00(0.9-9.1)
27,300(3,100-31,000)2.21/2.26
3.083.54
14.7-15.72.7
49/4953/54
930/9302,850/2,700
245×570×570/49×700×70016.0 (35) / 2.6 (6)
716×820×31542 (93)
6.35/15.8825/32
30 (15)20
-10 to 46-15 to 24
R410AUTG-UFYD-W
2-stage turbo fanAn evenly spread air distribution across the heat exchanger is possible due to the 2 stage turbo fan which produces two separate airflow streams.
In the case of a conventional fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven.
20 % UP
Heat exchangeefficiency:
AOYG18LBCB AOYG24LBCB
Wireless R.C.
AOYG18LBCB AOYG24LBCB
COMPACT CASSETTEINVERTER
055
285 285
Ceiling114
114
700
700
IR receiver
570
: In
door
uni
t
370
540
Han
ging
bol
t pos
ition
580
to 6
60Ce
iling
ope
ning
s
530
530Hanging bolt position
Drain hose
215
19 30 123
30 262
183
Control Box
146
40
Liquid pipe
Gas pipe
Dimensions (Unit : mm)AUYG18LVLB / AUYG24LVLA
The louver design distributes air leaving a space between the chassis and the ceiling allowing far and wide airflow distribution.
Optimized wing form (laminar wing type) and wing number (7 blades each)
Wired Remote Controller:
Simple Remote Controller:
External Switch Controller:
External Connect Kit:
Insulation Kit For High Humidity:
Fresh Air Intake Kit:
Cassette Grille:
Network Convertor for single split :(DC power supply type)
Network Convertor for single split :(AC power supply type)
Air Outlet Shutter Plate:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTY-TERX
UTY-XWZX
UTZ-KXGC
UTZ-VXAA
UTG-UFYD-W
UTY-VTGX
UTY-VTGXV
UTR-YDZB
Adoption of laminar wing
Spin direction Airflow direction
Airflow runs through smoothly along the laminar wing
No airflow separation
Laminar wing
Much less temperature irregularity by spreading airflow widely
Front part Ceiling
Rear part
50
40
30
20
10
0
-10
-20
Cooling
Heating
CATEGORY -
056
High efficiency turbo fan with 3-dimensional blade
Specifications
450mm 500mm
WindvelocityHeat exchanger
< Motor side >
Uneven airflow
Fast
SlowConventional blade
Separation phenomenon of airflow causes noise
: Spin direction : Airflow direction : Turbulent flow noise
< Motor side >Heat exchanger
3-dimensional blade
No airflow separation
Previous turbo fan: Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling.
New turbo fan: High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger.
Quiet
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
RefrigerantCassette Grille
Heating(Min-Max)
Cooling/HeatingInput Power
Power SourceCooling
(Min-Max)
Cooling
IndoorOutdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor / Grille
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/hkW
BTU/h
Model No.Indoor unit
Outdoor unit
AUAG30LRLA
AOAG30LBTA
230/1/508.50(2.8-10.0)
29,000(9,500-34,100)10.00(2.7-11.2)
34,100(9,200-38,200)2.54/2.77
3.353.61
11.1/12.22.5
40/4053/55
1,600/1,6003,600/3,800
288x840x840/50x950x95023.0(51)/5.5(12)
830x900x33061.0(134)9.52/15.8825.0/32.0
50(20)30
-15 to 46-15 to 24
R410AUTG-UGYA-W
AUAG36LRLA
AOAG36LBTA
230/1/5010.00(2.8-11.2)
34,100(9,500-38,200)11.20(2.7-12.7)
38,200(9,200-43,300)3.12/3.02
3.213.71
13.7/13.33.5
43/4354/55
1,800/1,8003,800/3,800
288x840x840/50x950x95023.0(51)/5.5(12)
830x900x33061.0(135)9.52/15.8825.0/32.0
50(20)30
-15 to 46-15 to 24
R410AUTG-UGYA-W
AUAG54LRLA
AOAG54LBTA
230/1/5013.3(4.5-14.5)
45,400(15,400-49,500)16.0(4.7-16.5)
54,600(16,000-56,300)4.42/4.69
3.013.41
19.3/20.55.0
47/4755/57
2,000/2,0006,750/6,850
288x840x840/50x950x95026.0(57)/5.5(12)1,290×900×330
86.0(190)9.52/15.8825.0/32.0
50(20)30
-15 to 46-15 to 24
R410AUTG-UGYA-W
AUAG45LRLA
AOAG45LBTA
230/1/5012.50(4.0-14.0)
42,700(13,700-47,800)14.00(4.2-16.2)
47,800(14,300-55,300)3.88/3.77
3.223.71
16.9/16.54.5
46/4655/55
1,900/1,9006,750/6,200
288x840x840/50x950x95026.0(57)/5.5(12)1,290×900×330
86.0(190)9.52/15.8825.0/32.0
50(20)30
-15 to 46-15 to 24
R410AUTG-UGYA-W
Model : AUAG30LRLA / AUAG36LRLA / AUAG45LRLA / AUAG54LRLA
AOAG30LBTAAOAG36LBTA
AOAG45LBTAAOAG54LBTA
Wired R.C.
CASSETTEINVERTER
057
Dimensions Models: (Unit : mm)
Detachable Grille corner
Adjustment can be done just taking off the corner part
High lift drain pump
Ceiling panel 850mmAdjustment of hanger position is possible after installation
358
9813
3
118
158
288
Drain pipe
Liquid pipe
Side view
Top view
Gas pipe
338278
950
950Bottom view
890
(Cei
ling
open
ings
)
699
(Bol
t pitc
h)
796 (Bolt pitch)
842 (indoor unit)
Low noise mode of outdoor unit (45/54 types)
2 stage low noise mode can be selected.(Option)
Rated noise value
Mode 1
Mode 2
Lownoisemode
-4 dB-2 dB
AUAG30LRLA / AUAG36LRLA / AUAG45LRLA / AUAG54LRLA
Optional parts
Wired Remote Controller:
Simple Remote Controller (3-wire type):
External Connect Kit:
Wide Panel:
Panel Spacer:
Cassette Grille:
Air Outlet Shutter Plate:
IR Receiver Unit:
Wireless LAN Adaptor:
External Connect Kit:
Insulation Kit For High Humidity:
Fresh Air Intake Kit:
UTY-RNNYM
UTY-RSNYM
UTD-ECS5A
UTG-AGYA-W
UTG-BGYA-W
UTG-UGYA-W
UTR-YDZC
UTY-LRHYA2
UTY-TFNXZ3
UTY-XWZX
UTZ-KXGA
UTZ-VXGA
Improvement of the airflow distribution New louver: The louver design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution.
Much less temperature irregularity by spreading airflow widely
Front part Ceiling
Rear part
Wide operation range
50
40
30
20
10
0
-10
-20 -15°C-15°C
Cooling
24°CHeating
46°C
PRODUCT CATEGO
RY - SPLIT
058
SpecificationsSpecifications
Floor console
Flexible installation
Under ceiling
Example for floor installation Example for ceiling installation
Model : ABYG18LVTB / ABYG24LVTA
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
Heating(Min-Max)
Cooling/HeatingInput Power
Power SourceCooling
(Min-Max)
Cooling
IndoorOutdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/hkW
BTU/h
Model No.Indoor unit
Outdoor unit
ABYG18LVTB
AOYG18LBCB
230/1/505.20(0.9-5.9)
17,700(3,100-20,100)6.00(0.9-7.5)
20,500(3,100-25,600)1.62/1.66
3.213.61
11.5-13.52.0
43/4350/50
780/7802,380/2,080
199×990×65527 (60)
632×799×29036 (79)
6.35/12.7025/32
25 (15)15
-10 to 46-15 to 24
R410A
ABYG24LVTA
AOYG24LBCB
230/1/506.80(0.9-8.0)
23,200(3,100-27,300)8.00(0.9-9.1)
27,300(3,100-31,000)2.21/2.26
3.083.54
14.7-15.72.7
48/4853/54
980/9802,850/2,700
199×990×65527 (60)
716×820×31542 (93)
6.35/15.8825/32
30 (15)20
-10 to 46-15 to 24
R410A
AOYG18LBCB AOYG24LBCB
Wireless R.C.
AOYG18LBCB AOYG24LBCB
FLOOR/CEILING UNIVERSALINVERTER
059
DimensionsDimensions Models: (Unit : mm)ABYG18LVTB / ABYG24LVTA
Right and Left Swing
1
2
5
43
5 steps selectable
StepsSwing: Cooling , Dry and Fan modeSwing: Heating and Fan mode
Up and Down Swing1
2
5
43
7 steps selectable
6
7
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
3
12
1
2
33
Wide operation range
High power DC fan motor
Double auto swingA combination of right/left and up/down directional swing allows 3-dimensional air direction control
Optional parts
Simple Remote Controller:
External Switch Controller:
Network Convertor for single split:(DC power supply type)
Network Convertor for single split:(AC power supply type)
External Connect Kit:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTY-TERX
UTY-VTGX
UTY-VTGXV
50
40
30
20
10
0
-10
-20 -15°C
Cooling
24°CHeating
-10°C
46°C
PRODUCT CATEGO
RY - SPLIT
060
Specifications
Installation Multi auto swing
A combination of right/left and up/down directional swing allows 3-dimensional air direction control.
StepsSwing: Cooling , Dry and Fan modeSwing: Heating and Fan mode
Right and Left Swing Up and Down Swing
5 steps selectable 5 steps selectable
1
2
5
4
3
12
54
3
(Field Supplied)
Open Concealed
Wall mounted
Model : ABAG30LRTA / ABAG36LRTA / ABAG45LRTA
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
Heating(Min-Max)
Cooling/HeatingInput Power
Power SourceCooling
(Min-Max)
Cooling
IndoorOutdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/hkW
BTU/h
Model No.Indoor unit
Outdoor unit
ABAG30LRTA
AOAG30LBTA
230/1/508.50(2.8-10.0)
29,000(9,500-34,100)10.00(2.7-11.2)
34,100(9,200-38,200)2.54/2.77
3.353.61
11.1/12.22.5
45/4553/55
1,660/1,6603,600/3,600
240×1,660×70046.0(101)
830x900x33061.0(134)9.52/15.8822.0/25.6
50(20)30
-15 to 46-15 to 24
R410A
ABAG36LRTA
AOAG36LBTA
230/1/509.40(2.8-11.2)
32,100(9,500-38,200)11.20(2.7-12.7)
38,200(9,200-43,300)2.93/3.02
3.213.71
12.8/13.23.0
47/4754/55
1,900/1,9003,800/3,800
240×1,660×70046.0(101)
830x900x33061.0(134)9.52/15.8822.0/25.6
50(20)30
-15 to 46-15 to 24
R410A
ABAG45LRTA
AOAG45LBTA
230/1/5012.10(4.0-13.3)
41,300(13,700-45,400)13.30(4.2-15.5)
45,400(14,300-52,900)3.77/3.68
3.213.61
16.5/16.14.0
49/4955/55
2,100/2,1006,750/6,200
240×1,660×70046.0(101)
1,290×900×33086.0(190)9.52/15.8822.0/25.6
50(20)30
-15 to 46-15 to 24
R410A
AOAG30LBTAAOAG36LBTA
AOAG45LBTA
Wireless R.C.
CEILINGINVERTER
061
Dimensions
Condensate lift-up mechanism (Option)
Optional drain lift-up mechanism allows flexible installation.
Fresh air intake
OutdoorIndoor
Freshair
Easy installation
Main work settings can be done easily from the remote controller at installation
Setting by wireless or wired remote controller
Conventional type
1 2 3
O F F
SW1(Optional parts)
Setting by DIP switch insidecontrol box
Main work settings
cooling / heating
Models: (Unit : mm)
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
3 1 32
3
Optional parts
Wired Remote Controller:
Simple Remote Controller (3-wire type):
External Connect Kit:
Drain Pump Unit:
External Connect Kit:
External Connect Kit:
Wide operation range
30
20
10
0
-10
-20 -15°C-15°C
Cooling
24°C
46°C
Low noise mode of outdoor unit (45/54 types)
2 stage low noise mode can be selected.(Option)
Rated noise value
Mode 1
Mode 2
Lownoisemode
-4 dB-2 dB
Max.
mm
PRODUCT CATEGO
RY - SPLIT
062
Model : ARYG18LLTB
Slim design
Drain port
The slim design allows installations where ceilings are narrow.Drain hose as standard accessory
2-type installation methods of ceiling concealed and floor concealed can be selected.
Drain pumpbuilt-in
Height
198mm
Drain pump
Flexible installation
Floor concealed
Ceiling concealed
Specifications
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
Heating(Min-Max)
Cooling/HeatingInput Power
Power SourceCooling
(Min-Max)
Cooling
IndoorOutdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/hkW
BTU/h
Model No.Indoor unit
Outdoor unit
ARYG18LLTB
AOYG18LBCB
230/1/505.20
17,700(3,100-20,100)6.00
20,500(3,100-25,600)1.62/1.66
3.213.61
7.2/7.42.032
50/50940/940
2,380/2,080198×900×620
23 (51)632×799×290
36 (79)6.35/12.70
25/3225 (15)
15-10 to 46-15 to 24
R410A
AOYG18LBCBAOYG18LBCB
Wired R.C.
SLIM DUCTINVERTER
063
Drain hose is standard accessory
Max.
850mm
Drain pump is standard accessoryIt allows flexible installation.
Static pressure range
0 to 90 Pa
Dimensions Models: (Unit : mm)ARYG18LLTB
*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.
(Bol
t pitc
h)
77451
152
377
174
713030
78
50
P100x8=800
850
934(Bolt pitch)
43
20
198
168
78
850900
12
69144263371
620
47557889119
167
Wide operation rangeSelectable with a wide range of static pressureBy using the DC fan motor, it is possible to change the static pressure range from 0 to 90 Pa.The change of static pressure range is possible by remote controller.
50
40
30
20
10
0
-10
-20 -15°C
Cooling
24°CHeating
-10°C
46°C
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Wireless LAN Interface
External Connect Kit:
Auto Louver Grille Kit:
IR Receiver Unit:
Remote Sensor Unit:
UTY-RNNYM
UTY-RSNYM
UTY-TFNXZ3
UTD-ECS5A
UTD-GXSB-W
UTY-LRHYM
UTY-XSZX
PRODUCT CATEGO
RY - SPLIT
Auto Louver Grille Kit (Option)
Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.
Wired RemoteController
Wireless RemoteController
4 steps selectable and auto swing
Auto Louver Grille Duct type
064
Slim & Compact design
Specifications
In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270 mm, Further space savings have been achieved by mounting the electrical control box internally inside the chassis.
1,135 mm
1,200 mm
270 mm
Control box is now included as part of the main chassis
One touch operating and easy to install long life filter (Optional Parts)
Model : ARYG24LMLA / ARAG30LMLA / ARAG36LMLA / ARAG45LMLA
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
Heating(Min-Max)
Cooling/HeatingInput Power
Power SourceCooling
(Min-Max)
Cooling
IndoorOutdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/hkW
BTU/h
Model No.Indoor unit
Outdoor unit
ARYG24LMLA
AOYG24LBCB
230/1/506.80(0.9-8.0)
23,200(3,100-27,300)8.00(0.9-9.1)
27,300(3,100-31,000)2.21/2.26
3.083.54
14.7/15.72.5
31/3153/54
1,100/1,1002,850/2,700
270×1,135×70038.0 (84)
716×820×31542 (93)
6.35/15.8835.7/38.130 (15)
20-10 to 46-15 to 24
R410A
ARAG30LMLA
AOAG30LBTA
230/1/508.50(2.8-10.0)
29,000(9,500-34,100) 10.00(2.7-11.2)
34,100(9,200-38,200) 2.65/2.68
3.21 3.73
11.6/11.7 2.5
39/4253/55
1,900/2,1003,600/3,600
270x1,135x700 37.0(82)
830x900x330 61.0(134)9.52/15.8835.7/38.1 50(20)
30 -15 to 46 -15 to 24
R410A
ARAG36LMLA
AOAG36LBTA
230/1/509.40(2.8-11.2)
32,100(9,500-38,200)11.20(2.7-12.7)
38,200(9,200-43,300)2.96/3.10
3.183.61
13.0/13.63.0
39/4254/55
1,900/2,1003,800/3,800
270x1,135x70037.0(82)
830x900x330 61.0(134)9.52/15.8835.7/38.1
50(20)30
-15 to 46-15 to 24
R410A
ARAG45LMLA
AOAG45LBTA
230/1/5012.10(4.0-13.3)
41,300(13,700-45,400)13.30(4.2-15.5)
45,400(14,300-52,900)3.77/3.68
3.21 3.61
16.5/16.1 4.0
42/42 55/55
2,100/2,1006,750/6,200
270x1,135x700 39.0(86)
1,290×900×330 86.0(190) 9.52/15.88
35.7/38.1 50(20)
30 -15 to 46 -15 to 24
R410A
AOAG30LBTAAOAG36LBTA
AOYG24LBCB AOAG45LBTA
Wired R.C.
AOYG24LBCB
MEDIUM STATIC PRESSURE DUCTINVERTER
065
Dimensions Models: (Unit : mm)
Easy maintenance
See below for the case of rear suction type
Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed.
1.Control box
2.Fan casing
3.Fan
4.Motor
Previous model
2
4
13
Large bottom panel: 1 piece
1
4
32
Bottom panel: 2 pieces
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
3
Rear view
Top viewSide view (R)Side view (L)
Front view
240270
10710151135
17316
1
447(
Bolt
pitc
h)
1177(Bolt pitch)Outlet270
32ø200
(knock out hole)
240
121
P.C.D. ø225
1146632
1
3
3
2
168
281
240
700
138
138
264 264 264
ø205 hole
82
75
ARYG24LMLA / ARAG30LMLA / ARAG36LMLA / ARAG45LMLA
Optional parts
Wired Remote Controller:
Simple Remote Controller (3-wire type):
Remote Sensor Unit:
Drain Pump Unit:
Network Convertor for single split:(DC power supply type)
Network Convertor for single split:(AC power supply type)
External Switch Controller:
Wireless LAN Adaptor:
External Connect Kit:
Long-Life Filter:
Flange (Round):
Flange (Square):
IR Receiver Unit:
External Connect Kit:
UTY-RNNYM
UTY-RVNYM (24)
UTY-RSNYM
UTY-XSZX
UTZ-PX1NBA
UTY-VTGX (24)
UTY-VTGXV (24)
UTY-TERX (24)
UTY-TFNXZ3 (30/36/45)
UTD-ECS5A
UTD-LF25NA
UTD-RF204
UTD-SF045T
UTY-LRHYM
UTY-XWZXZ3 (36/45)
Easy installation
Main work settings can be done easily from the remote controller at installation
Setting by wired remote controller
Conventional typeSetting by DIP switch insidecontrol box
Main work settings
cooling / heating
1 2 3
O F F
SW1
Wide operation range
50
40
30
20
10
0
-10
-20 -15°C-10°C
-15°C
Cooling
24°CHeating
46°C
(24 type only)
PRODUCT CATEGO
RY - SPLIT
066
Max.
260 paMax.
250 pa
Specifications
Design also corresponding tohigh static pressure
Model : ARYG45LHTA / ARYG54LHTA / ARYG45LHTA [3 phase] / ARYG54LHTA [3 phase] / ARYG60LHTA [3 phase]
Capacity
EERCOPRunning CurrentMoisture Removal
Airflow Rate (High)(Cooling/Heating)
Sound Pressure Level(Cooling/Heating)
Net Dimension H x W x DNet Weight
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
Heating(Min-Max)
Cooling/HeatingInput Power
Power SourceCooling
(Min-Max)
Cooling
IndoorOutdoor
Indoor (High)Outdoor
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/HzkW
BTU/hkW
BTU/h
Model No.Indoor unit
Outdoor unit
ARYG45LHTA
AOYG45LETL
230/1/5012.5(5.0-14.0)
42,700 (15,400 - 47,800)14.0(5.0-16.0)
47,800 (17,100 - 55,300)4.30/3.80
2.913.68
19/171.5
47/4755/55
3,350/3,3506,750/6,200
400×1,050×50046 (101)
1,290×900×33086 (189)
9.52/15.8823.4/25.450 (20)
30-15 to 46-15 to 24
R410A
ARYG54LHTA
AOYG54LETL
230/1/5013.4(5.0-15.0)
45,700 (17,100 - 49,500)16.0(6.0-18.0)
54,600 (18,800 - 61,500)4.77/4.69
2.813.41
21/212.0
47/4755/57
3,350/3,3506,750/6,850
400×1,050×50046 (101)
1,290×900×33086 (189)
9.52/15.8823.4/25.450 (20)
30-15 to 46-15 to 24
R410A
ARYG45LHTA
AOYG45LATT
400/3/5012.5(5.0-14.0)
42,700 (17,100 - 47,800)14.0(5.0-16.0)
47,800 (18,400 - 55,300)4.06/3.67
3.083.816/61.5
47/4754/54
3,350/3,3506,750/6,200
400×1,050×50046(101)
1,290×900×330104(229)
9.52/15.8823.4/25.4
75(30)30
-10 to 46-15 to 24
R410A
ARYG54LHTA
AOYG54LATT
400/3/5014.0(5.0-16.0)
47,800 (18,400 - 54,600)16.0(6.0-18.0)
54,600 (19,800 - 61,500)4.65/4.37
3.013.667/72.5
47/4755/56
3,350/3,3506,900/6,900
400×1,050×50046(101)
1,290×900×330104(229)
9.52/15.8823.4/25.4
75(30)30
-10 to 46-15 to 24
R410A
ARYG60LHTA
AOYG60LATT
400/3/5015.0(6.0-18.0)
51,200 (21,200 - 60,000)18.0(6.0-20.0)
61,500 (21,200 - 68,300)4.70/5.15
3.193.507/82.0
45/4556/58
3,350/3,3506,900/7,300
425×1,250×49054(119)
1,290×900×330104(229)
9.52/15.8823.4/25.4
75(30)30
-10 to 46-15 to 24
R410A
45/54 models 60 model
(60)(45/54)
Wired R.C.
AOYG45/54LETLAOYG45/54/60LATT
HIGH STATIC PRESSURE DUCTINVERTER
067
Front view
Top viewSide view (L)
Side view (R)
Rear view
88
4001,080
1,000 (Bolt pitch)862
8511,050 85
371356
208
41 123
139108
1
2
3
4
324 14
295
585
500(
Bolt
pitc
h)
71
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)
Drain piping connection (Safety drain pan)
21 Refrigerant piping flare connection (Liquid)
Refrigerant piping flare connection (Gas)21
3
Drain piping connection(Main drain pan)4
Top view
Rear view
Front view
Side view (L)Side view (R)
1
2
425351 14
30304 921 152
87
1062 10639
400382
272
28 119
146
172
490
1260
1232
1250
4457
2
3052
6 (B
olt p
itch)
1192 (Bolt pitch)
39
181
43 dB(A)
Dimensions (Unit : mm)
ARYG45LHTA / ARYG54LHTA ARYG60LHTA
Cutting off the corners has enabled less turbulent airflow. Low noise is realized by adopting a plastic case and a plastic fan.
Significantly greater efficiency is realized by using all DC inverter technology. (60 model)
A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight.
Wired Remote Controller:
Simple Remote Controller:
External Switch Controller:
Remote Sensor Unit:
Network Convertor for single split:(DC power supply type)
Network Convertor for single split:(AC power supply type)
External Connect Kit:
IR Receiver Unit
Long-Life Filter:
UTY-RNNYM, UTY-RVNYM
UTY-RSNYM
UTY-TERX
UTY-XSZX
UTY-VTGX
UTY-VTGXV
UTD-ECS5A
UTY-LRHYM (60)
UTD-LF60KA (45/54)
50
40
30
20
10
0
-10
-20
Cooling
Heating
60 model
(unit: mm)
45/54 models
1,050 500
400
1,250 490
425
CATEGORY -
45/54 models
Heat exchanger
Plastic fan
Casing (Plastic)
ø225 mm
FEATURE SUMMARYMAFEATU MMSUAAT RYMA MSUMSSRE SUAATURU UMMAEATURE SUMMATURE SUMMTURE S MSREFEATURE SUMMEA
Country
Type Wall Mounted Wall MountedCassette
Air Conditioning Type
Model No.
Energy Saving Function
Economy mode
Energy saving mode
Save human sensor
Room temperature set point limitation
Set temperature auto return
Double swing automatic
Connectable fresh air duct
Connectable distributing duct
Individual airflow direction control
Weekly + setback timer
Ion deodorization filter
10°C HEAT operation
Comfortable Function
Low noise mode
Auto-changeover
Up/down swing flaps
Automatic fan speed
Auto restart
Fresh air intake
Convenient FunctionClean Function
Installation
For Inverter type
Auto off timer
Sleep timer
Program timer
Weekly timer
Filter sign
Apple-catechin filter
Washable panel
PM2.5 Filter
Drain pump as standard
Blue fin
for Vietnamfor Singapore
Heating &Cooling
ASYG09/12/14
LUCAASAA09/12JGC ASAG18/24JFCB ASAG30JFTB
AUAG36/45LRLD-A
ASAG09/12/18/24
CPTA-V
AUAG24LRLA-AAUAG36LRLC-A
ASAG09LLTB-VASAG12LLTA-V
Power diffuser
Powerful mode
Wireless LAN control
Heating &CoolingHeating & CoolingCooling only Cooling only
(24)
(24)
068
PRODUCT CATEGO
RY - SPLIT
AUXG18/24/30/36/45/54
LRLB
AUAG30/36/45/54
LRLA
ASAA18/24/30
JCC
ABYG18LVTB,ABYG24LVTA
ABAG30/36/45
LRTAARYG18LLTB
ARYG24LMLA,
ARAG30/36/45
LMLA
ARYG45/54/60
LHTA
(45/54) (45)
AUYG18LVLB,AUYG24LVLA
ASAG09/12JLTB-V
ASAG09/12JLCA
(60)
(60)
(60)
069