Post on 17-Jan-2022
transcript
(PH)
9.1m
7.6m
39
7
O
LD
W
O
R
T
H
IN
G
R
O
A
D
3
1
15
77
17
7
2
6
12
24
1
E
T
L
1
6
6
2
6
a
P
a
th
(u
m
)
Hotel
17
Kelston House
Appletree Cottage
3
7
11
8
16
M
A
Y
F
I
E
L
D
8
25
2
15
11
Ward
Bdy
ESS
ESS
D
ef
65
12
1
14
2
2
a
TH
AK
EH
AM
C
LO
SE
1
7
28
2
0
Sub
12
The Roundstone
Lachine
BU
RW
AS
H C
LO
SE
51
HA
ILS
HA
M C
LO
SE
RO
UN
DS
TO
NE
BY
PA
SS
RO
AD
AR
LIN
G
TO
N C
RE
SC
EN
T
2
Roundstone
2
2
6
3
0
7.3m
28a
1
House
Heanton
El
1
19
Sta
Shelter
6
3
P
E
L
P
2
5
0
P
E
L
P
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
JB
110
JB
110
JB
110
8x110Ø
1x110Ø
8x110Ø
4x110Ø
8
x1
1
0
Ø
8
x1
1
0
Ø
4x110Ø
4x110Ø
4x110Ø
8x110Ø
5x110Ø
1
x1
1
0
Ø
1
x
1
1
0
Ø
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
JB110
5x110Ø
1x110Ø
2x110Ø
5x110Ø
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
4x110Ø
4x110Ø
JB
10
4
JB
111
JB106
JB
111
5x110Ø
5x110Ø
X
X
CH
1300m
C
H
1
3
5
0
m
C
H
1
4
0
0
m
C
H
1
4
5
0
m
C
H
1
5
0
0
m
C
H
1
5
5
0
m
CH
1600m
JOINT BAY 6 AT CH 1460m.
REFER TO DRAWING
831364-SDS-DR-CV-A259-1003
FOR DETAILS
PILO
T C
H 1500m
6" CI WATER MAIN CROSSING.
REFER TO DRAWING
831364-SDS-DR-CV-A259-1006
FOR DETAILS
6m
CROSSING SURFACE
WATER SEWER.
RECORDS INDICATE A
DEPTH OF 1.2m
A
A
A
A
A
A
A
A
D
D
CROSS SECTION A-A
SCALE 1:20
GL
670
100
75
900 F
OR
V
ER
GE
/ C
AR
RIA
GE
WA
Y
1050 F
OR
A
RA
BLE
LA
ND
1175 F
OR
V
ER
GE
/ C
AR
RIA
GE
WA
Y
1325 F
OR
A
RA
BLE
LA
ND
450
50 50
BACKFILL USING SELECTED
ARISINGS FROM EXCAVATION/
COMPACTED TYPE 1 TO COMPLY
WITH HAUC SPEC.
3 x 1000 x 244 x 9mm STOKBORD
2x 200mmØ OD EMTELLE uPVC DUCTS
FOR 300mm² Al XLPE 33kV CACLES & 1x
88.9mmØ OD EMTELLE uPVC DUCT FOR
19-PAIR PILOT CABLE
CBS SURROUND AS PER ENA TS
97-1
SURFACE REINSTATED TO MATCH
EXISTING CONSTRUCTION
CROSS SECTION D-D
SCALE 1:20
GL
670
100
75
525
800
450
50 50
BACKFILL USING SELECTED
ARISINGS FROM EXCAVATION/
COMPACTED TYPE 1 TO COMPLY
WITH HAUC SPEC.
2x 900x300x 9mm STEEL PLATES
PAINTED WITH A SINGLE COAT OF
BITUMASTIC PAINT &
3 x 1000 x 244 x 9mm STOKBORD
2x 200mmØ OD EMTELLE uPVC DUCTS
FOR 300mm² Al XLPE 33kV CACLES & 1x
88.9mmØ OD EMTELLE uPVC DUCT FOR
19-PAIR PILOT CABLE
CBS SURROUND AS PER ENA TS
97-1
SURFACE REINSTATED TO MATCH
EXISTING CONSTRUCTION
Project
Drawing Title
Designed
Checked
Approved
Drawn
Signed Date
DateSigned
DateSigned
DateSigned
Suitability
Scale
Code
Revision
Sheet
Drawing Number
Status
Rev Date Description of Revisions Drawn Chkd
Contractor(s)
Legend/Notes
Appr
of
PART OF THE KIER GROUP
DESIGN SERVICES
Alternative Reference
A259 BRIDGE ROAD
S. ORR
J.MOK
-
1:500
831364-SDS-DR-CV-A259-1001
07
19.03.21
19.03.21
-
PSC DESIGN STAGE
33kV CABLE ROUTE DIVERSION
M.STOCKDALE 19.03.21
P01
S.ORR 19.03.21
P01 19.03.21 FIRST ISSUE SO JM MS
1. ALL DIMENSIONS IN mm UNLESS STATED OTHERWISE.
2. DO NOT SCALE FROM THIS DRAWING.
3. THE CONTRACTOR MUST UNDERTAKE A SERVICES SEARCH IN
THE VICINITY OF THE WORKS BOTH VISUALLY AND USING
APPROVED CAT EQUIPMENT.
4. ALL SURFACE REINSTATEMENT TO BE IN LINE WITH
LANDOWNER / LOCAL AUTHORITY REQUIREMENTS.
5. MINIMUM CABLE BENDING RADII & CABLE MAXIMUM PULLING
TENSIONS TO BE OBSERVED AT ALL TIMES. SUFFICIENT
LABOUR & EQUIPMENT TO INSTALL CABLE WITHOUT CAUSING
DAMAGE TO IT OR OTHER SERVICES SHALL BE USED AT ALL
TIMES.
6. CABLES MAY BE INSTALLED WITH MINOR HEIGHT CHANGES IN
ORDER TO ACCOMMODATE THE EXISTING UNDERGROUND
SERVICES. HOWEVER, THIS MUST BE KEPT TO A MINIMUM.
7. ALL STAFF & SUB-CONTRACTORS TO CARRY AN UKPN STREET
WORKS POLICY & UKPN EXCAVATION & CABLE INSTALLATION
MANUAL.
8. INSPECT CABLE DRUMS & CABLE FOR DAMAGE BEFORE
INSTALLATION.
9. CABLE TO BE PULLED FROM TOP OF DRUM TO AVOID DAMAGE
TO CABLE.
10. CABLES TO BE PULLED AS SPECIFIED IN APPENDIX B OF
ENATS 09-02.
11. INSTALL CABLE WHEN AMBIENT AIR TEMPERATURE IS ABOVE
0°C FOR AT LEAST 24 HOURS.
12. GS6 GOALPOSTS ARE REQUIRED WHEN CROSSING EXISTING
OVERHEAD LINES. APPROPRIATE GS6 SETUP IN ACCORDANCE
WITH HSE "AVOIDING DANGER FROM OVERHEAD POWER
LINES GUIDANCE NOTE GS6 (FOURTH EDITION)" IS REQUIRED.
13. ALL LP GAS, LV, 11kV, BT & COMS CABLES ARE ASSUMED TO
BE INSTALLED AT DEPTHS AS PER NJUG GUIDELINES
KEY
Proposed 300mm
2
AL 33kV Cable
Proposed 19-Pair Pilot Cable
Proposed 33kV Joint Bay
Proposed Cable Pulling Chamber
33kV Cable - Bi-Directional Pull
Pilot Cable- Bi-Directional Pull
33kV Cable Reverse Pull Only
BT Cable
LP Gas
MP Gas
IP Gas
33kV Cable
11kV Cable
LV Cable
Foul Water
Surface Water
Water
GS6 Goalposts
06
-
CABLE ROUTE DRAWING
DISTANCE BETWEEN JOINTSCABLE SECTION LENGTH (m)
JB2 - JB3 20
JB3 - JB4 319
480
33kV JOINT BAYREFERENCE
COORDINATES
X (EASTING): Y (NORTHING):
JB1 506605.491 102923.923
JB2 506494.800 102964.685
JB3
ANGMERING SUBSTATION (JB1) - JB2 161
506497.125 102984.254
JB4
JB5
JB6
JB7
JB4 - JB5
JB5- JB6
JB6 - JB7
480
340
506638.157 103181.067507116.949 103200.895507596.364 103208.425507916.782 103177.648