Exploring the technology - Process Controls And ... › Hirotronix › pdf › ... · Exploring the...

Post on 28-Jun-2020

0 views 0 download

transcript

Exploring the technology....

Safety PLC´s with integrated safe motion control according to PL e of EN 13489 und SIL3 of the EN 61508

Conventionally safety technology and safety engineering:Protecting the machines working area - stop in case of entering the safety zone

Until now - Safe operation requires to seal off the operational area!

A violation of the saftey zone results a stop of the plant!

The BBH Products technology provides a safe reduced operating ofthe machine ...

BBH Products technology provides...• Safe limited speed • Safe limited revolutions• Safe limited torque • Safe limited acceleration / braking ramps• Safe position• Safe limited operational zone• Safe direction• Safe cam • Management of safety-related equipment• Safe indexing, jogging operation• Safe stop, safe operational stop• Safe standstill• Safe communication

Innovation in safety technology:Safe Motion Control

Functional monitoring of the driveOnly cutoff in case of failure

Safety related devices and non safe equipment can be managed by the SafetyPilot and SMX

Sensoren

laser distance sensors

barcode readers

Magnetostrive Sensoren

incremental and absolut encoders

magnetic bandtravel-position-system

All different kind of non-safe sensors can be used for motion monitoring!

magnetostriction position sensors

SSI Signal 24 bit- SSI gray code- SSI binaryin Master Mode (only connected to SafetyPilot or SMX)in Listener Mode (slave mode with another SSI Master)Up to 150 kHz SMX up to 500 kHz

Incremental encoders variable resolutions- channel A/B TTL (signal 5 VDC)- powersupply 24 VDC of encoder- SMX supports variable Voltage of powersupply

Sinus / Cosinus Encoders physical layer +/-1 V measuring signal A/B – track with 90 degrees phase difference Maximum frequency of the input clock pulses 200 KHz

Hiperfacevia te feedback connection of an inverter or servo drive

Resolvervia a A/D converter

The SafetyPilot and SMX supports encoders:

[2]

[3]

[4]

[5]

[6]

[10]

[11]

[12]

[7][8]

[9][1]

[2]

[3]

[4]

[5]

[6]

[10]

[11]

[12]

[7][8]

[9][1]

1: Function button

2: X1: Analog connection 1 and 2 each via differential input signal

3: X2: Pulse outputs P1 and P2 and digital inputs DI1 to DI8

4: X3: Auxiliary outputs DO1 and DO2, pulse outputs P1 and P2 and supervision inputs for external contact supervisionESC1 and ESC2

5: X4: Power supply voltage DC 24 V

6: X5: Safety relay K1 to K4

7: State display of the component

8: State - LED: DC 24 V OK

State - LED: System A OK (flashing)

State - LED: System B OK (flashing)

State - LED: Watchdog OK

9: Address setting for bus connection and Ethernet

10: X6: Diagnosis and configuration interface ( Ethernet )

11: X7: Connection of a speed sensor channel A

12: X8: Connection of a speed sensor channel B

SP100.02/PS

SP100.02/PB,SB1: Function button

2: X1: Analog connection 1 and 2 each via differential input signal

3: X2: Pulse outputs P1 and P2 and digital inputs DI1 to DI8

4: X3: Auxiliary outputs DO1 and DO2, pulse outputs P1 and P2 and supervision inputs for external contact supervision ESC1and ESC2

5: X4: Power supply voltage DC 24 V

6: X5: Safety relay K1 to K4

7: State display of the component

8: State - LED: DC 24 V OK

State - LED: System A OK (flashing)

State - LED: System B OK (flashing)

State - LED: Watchdog OK

9: Address setting for bus connection and Ethernet

10: X6: Diagnosis and configuration interface ( Ethernet )11: X7: Connection of a speed sensor channel A

12: X8: Connection of a speed sensor channel B

13: State - LED

14: Connection plug PROFIsafe

[2]

[3]

[4]

[5]

[6]

[10]

[11]

[12]

[7][8]

[9][1]

[14]

[13]

More than one SafetyPilot can communicate with another Safety PLC via safe bussystem

Topology..

Control panel of drilling rig

Control panel of nuclear power plant Brunsbüttel, Germany

Control Panels / Cabinets

The powerful technology functions..

Monitoring of positively guided contacts. The contacts to be monitored are in a series connection and N.C. – It will be (functional) monitored, if the contacts are normally closed.

EMU (Emergency Monitoring Unit)

Monitoring of cuttoff channels

SLS(Safely Limited Speed)

Maximum speed / maximum revolution

The powerful technology functions...

Monitoring of the maximum speed or revolution of a drive

SDI(Safe Direction)

Direction recognition

Monitoring of the preset rotating direction / moving direction

⇒ Relieving during activated safety devices

⇒ Run out of the dangerous / forbidden zone

SDI(Safe Direction)

Direction recognition

SOS(Safe operating Stop)

Standstill monitoring

Standstill monitoring of a drive at actual position with released drive and activated closed loop position controller.

SLP(Safely-limited Position)

monitoring of position-zones including revolution and speed monitoring as well as ramps and transition

monitoring of parameterized zone with a dedicated MIN/MAX and max. revolution / speed out of MIN/MAX= TRUEwithin of MIN/MAX= TRUE if actual revolution / speed is lower than MIN/MAX

SCA(Safe Cam)

monitoring of maximum cruising range

Monitoring of the admitted speed relatively to the related speed to the maximum limit of the cruising range. This function replaces all conventional limit switches!

Sample application multiple axis monitoring logistics / high rise rack- Transfaster

SCA(Safe Cam)

Sample application multiple axis monitoring logistics / high rise rack- Transfaster

SCA(Safe Cam)

SEL(Safe Emergency Limit)

Monitoring of variable target approach

Monitoring of admitted speed in relation to the relatively distance to a parameterized target position.

2xTSafetyBus 2xTSafetyBus

Fahrbefehl an SPSBremsen

Geschwindigkeit

TPSS TPSS TPSS 2xTSafetyBus

After detecting an E-Stop event the drop out of the speed of a drive will be monitored via time frame

SSx(Safe Stop 1,2)

Emergency stop monitoring of a drive

SLI(Safely Limited Increment)

Monitoring of indexing motion of a drive

Monitoring of the maximum jog skip = relative cruising range for not interrupted driving during jog operation

SAC(Safe Analog Control)

Monitoring of an analog input signal

Monitoring of an parameterized 0..10V / 4-20mA MIN/MAX range1 threshold value on the SafetyPilot 5 threshold value on the SMX platform

Safety Monitor Modular – SMX

ModularThe Safe PLC SMX offers the possibility to conect safe and not safe moduls on the rack via backplane bus.

Basicmoduls

USB Programmininterface

Display

Terminal blocks for input and output signals

LED´s for status

Functionbutton for Reset and CRC Display

Basic modulewith sensorinterface

Sensorinterface for safety related drive supervision

Input for additional second channel proximity switch

Basicmodul SMX 10

Safety PLC according to Cat. 4 / SIL3 with - 14 digital inputs - 2 Pulse outputs- 2 Relay outputs- 2 LOSIDE- 2 HISIDE- Programminginterface USB

Open programming via SafePLC-SMX Software or for special application only by changing parameters

cycle time ~ 8ms or fastchannel < 2ms

Basicmodul SMX 11

Safety PLC according to Cat. 4 / SIL3 with - 14 digital inputs- 1 sensorinterface - 1 counter inputs (incremental)- 2 Pulse outputs- 2 Relay outputs- 2 LOSIDE- 2 HISIDE- programminginterface USB

Open programming via SafePLC-SMX Software or for special application only by changing parameters

cycle time ~ 8ms or fastchannel < 2ms

Basicmodul SMX 12

Safety PLC Kat.4 / SIL3 mit - 2 sensorinterface for

2 axis Cat. 3/4 – SIL2/3 or 1 axes Cat. 4 – SIL 3 depending on mechanical Situation

- 2 counter inputs (incremental)- 14 digital inputs- 2 Pulse outputs- 2 Relay outputs- 2 LOSIDE- 2 HISIDE- programminginterface USB- 4x2 safe analog inputs

(4-20mA oder 0-10 Volt)- programminginterface USB

Open programming via SafePLC-SMX Software or for special application only by changing parameterscycle time ~ 8ms or fastchannel < 2ms

Axis enhancement module

SMX 21

Modul für one axes Cat.4 / SIL3 with - 8 digital inputs- 1 sensorinterface - 1 counter inputs (incremental)- 2 pulse outputs- 2 LOSIDE- 2 HISIDE

The axis information / safe position will be communicated via the internal backplane between the moduls.

Axis enhancement module

SMX 22

Safety PLC Kat.4 / SIL3 mit - 2 sensorinterface for

2 axis Cat. 3/4 – SIL2/3 or 1 axes Cat. 4 – SIL 3 depending on mechanical Situation

- 2 counter inputs (incremental)- 14 digital inputs- 2 Pulse outputs- 2 Relay outputs- 2 LOSIDE- 2 HISIDE

The axis information / safe position will be communicated via the internal backplane between the moduls.

I/O enhancement module

SMX 31

I/O expansion modul- 8 digital inputs- 8 selective configurable In or outputs

I/O enhancement module

SMX 33

Analog input modul with- 4x2 analog, safe inputs

(4-20 mA or 0-10 Volt)

Communication module

SMX 41

Safe ethernet (propritary)BBH-NET

Communication

module SMX 43ProfiNet with ProfiSafe V2

Communication

module SMX 51CAN module

Communication

module SMX 52ProfiBUS – DP

Producer

Communication module

SMX 53CanOpen

Most of our customer are in the following businesses

amusement rides

mountain railways, skilifts, cable cars

cranes and hoists

industrial kiln

press

robotics

automotive industry

nuclear power plants

blow film plants / winders

high stcking racks

conveying technology

machines with manual interaction of operators