Failure Analysis Study of a Cracked Superheater Outlet … A detailed failure analysis study has...

Post on 17-Jul-2018

216 views 0 download

transcript

© Riley Power Inc., 2012 www.babcockpower.com

Failure Analysis Studyof a Cracked Superheater Outlet Header

by

Robert L. RolandCAJUN ELECTRIC POWER COOPERATIVE, INC.

Baton Rouge, Louisiana

James P. King

a Babcock Power Inc. company(formerly Riley Stoker Corporation)

David P. Kalmanovitch

a Babcock Power Inc. company(formerly Riley Stoker Corporation)

Presented at City Public Service San Antonio

January 18-20, 1994San Antonio, Texas

Technical Publ icat ion

RST-124

RILEY POWER INC.

RILEY POWER INC.