Post on 02-Jul-2021
transcript
Fire and security products and services LPCB certification – a mark you can trust
www.redbooklive.com
LPCB (the Loss Prevention Certification Board) has been working with industry, specifiers and government since 1868 to set the standards needed to ensure that fire products and services perform effectively.
LPCB offers third-party approval to European, International, British and its own Loss Prevention Standards (LPS). LPCB, part of BRE Group, is accredited by the United Kingdom Accreditation Service (UKAS). BRE Global also offers approval to Management Systems standards.
LPCB certification provides assurances to all parties involved in construction projects, from the product manufacturer, specifier, asset owner, insurer, mortgage company through to the end user. Independent third party certification demonstrates that the product/service is produced consistently and will perform as specified.
Visit LPCB’s RedBook to search listed products, companies and download LPCB standards www.redbooklive.com.
Performance claims for fire and security products and services that are not backed up by third-party certification can be misleading. Third-party certification provides independent confirmation that products and services have met – and will continue to meet (given correct installation and maintenance) – appropriate standards.
2
MANAGEMENTSYSTEMS
Not all fire and security products and services on the market can be trusted in the event of a fire or an attempted break-in
Correctly specifying and installing fire resisting systems and fire protection construction products – often called passive fire protection products – is fundamental to fire safety in buildings. The products, systems and services certified by LPCB include:
– Steel protection systems – Board and cementitious coverings – Intumescent paints – Fire retardant coatings
– Cladding and rainscreen systems
– Partitions, cavity barriers and penetration seals
– Fire doors, shutters and glazing
– Floors, ceilings, wall linings and enclosures
– Fire resisting ductwork and fire dampers
– Components and construction products for use in the rail transport sector, surface and sub-surface transport applications
– Products for use in marine applications
– Companies installing passive fire protection systems and fire protection construction products.
Fire protection construction products and systems installationKey standard Description
LPS 1056Requirements for the LPCB approval and listing of fire doorsets, lift landing doors and shutters
LPS 1107 Structural steelwork
LPS 1132 Wall and floor and linear gap seals
LPS 1158 Fire resistant glazing systems
LPS 1162Requirements and tests for the LPCB approval and listing of fire dampers
LPS 1181 Part 1
Built-up cladding and sandwich panel systems for use as the external envelope of buildings
LPS 1181 Part 2
Sandwich panels and built-up systems for use as internal constructions in buildings
LPS 1195 Part 1
Temporary buildings for use on construction sites
LPS 1196Exposed surfaces having Reaction to Fire classification of Class 0
LPS 1207 Protective covering materials
LPS 1208Elements of construction used to provide compartmentation
LPS 1215 Scaffold cladding materials
LPS 1501 Innovative methods of building construction
LPS 1505 Roofing systems
LPS 1581Non-load bearing external cladding systems applied to the masonry face of a building
LPS 1582 Non-load bearing external cladding systems fixed to and supported by a structural steel framework
BD 2569Fire protected stairs: LPCB/ British Woodworking Federation (BWF) scheme
BS 476-4 Fire tests on building materials and structures. Non-combustibility test for materials
BS 476-21 Fire resistance of load bearing elements of construction
BS 476-22 Fire resistance of determination of the fire resistance of non-load bearing elements
EN 13381-3 Fire resistance of structural applied protection to concrete members – applied protection
EN 13381-8 Fire resistance of structural applied reactive protection to steel members – applied protection
EN 13501-1 Fire classification of construction products and building elements
ENV 1187 External fire exposure to roofs
ISO 843-10 Fire resistance tests for applied fire protection materials to structural steel elements
SD100 Surface and sub-surface transport applications where the means of escape is limited
Installing and maintaining schemesKey standard Description
LPS 1197Inspecting, repairing and maintaining fire and security doors, doorsets, shutters and active smoke/fire barriers
LPS 1271Installing fire and security doors, doorsets, shutters and active smoke/fire barriers
LPS 1500Installing construction elements used to provide compartmentation in buildings
LPS 1531 Installing or applying passive fire protection products
LPS 2084 Inspecting, cleaning and maintenance of ductwork systems
3
Fire resisting systems and fire protection construction products
Fire detection and alarm products and systems that are correctly designed, manufactured, installed and maintained can help provide early warning of fire that can help save lives.
Fire detection and alarm products, systems and cablesKey standard Description
LPS 1014 Certificated fire detection and alarm system firms
LPS 1020 Alarm receiving centres
LPS 1054Component compatibility for fire detection and alarm systems
LPS 1257 Radio linked fire detection and fire alarm equipment
LPS 1259Alternative specification for control and indicating equipment for use in countries not bound by CEN/CENELEC internal regulations
LPS 1265Carbon monoxide fire detectors using electrochemical cells
LPS 1274Carbon monoxide/heat multisensory fire detectors using electrochemical cells
LPS 1277 Alarm transmission equipment
LPS 1279Point multisensory fire detectors using optical or ionization smoke sensors and electrochemical cell CO sensors and, optionally, heat sensors.
LPS 1280 Duct smoke detectors using point smoke detectors
LPS 1282Combined domestic smoke and carbon monoxide detectors
LPS 1653 Fire detection and fire alarm network systems
BS 6387Cables required to maintain circuit integrity under fire conditions
BS 7629-1 Insulated cables with limited circuit integrity
BS 7846
Electric cables. Thermosetting insulation, armoured, fire resistant cables of rated voltage 600/1000V having low emission of smoke and corrosive gases when affected by fire specification
BS 8434-2
Methods of test for assessment of the fire integrity of electric cables. Test for unprotected small cables for use in emergency circuits. BS EN 50200 with a 930 deg flame and with waterspray
EN 54Series of standards for fire detection and alarm systems and individual components
EN 14604 Smoke alarm devices
EN 50200Fire resistance of unprotected small cables for use in emergency circuit
EN 50291 Domestic carbon monoxide detectors
EN 60702-1 Mineral insulated cables
4
Fire detection and alarm products, systems and cables
– Smoke, heat and multi-sensor detectors
– CO detectors
– Flame, beam and aspirating detectors
– Manual call points
– Sounders, loudspeakers and visual alarm devices
– Input/output devices and short circuit isolators
– Control and indicating equipment and power supply equipment
– Voice alarm control and indicating equipment
– Fire extinguishing panels
– Fire cables
– Installers of fire detection and alarm systems
– Wireless detectors
Fire detection and alarm products, systems and cables, approved by LPCB include:
To maximise the protection offered to people and property specifiers should ensure that:
– Products are tested and certified to an appropriate standard
– Fire detection and alarm systems are tested and certified for system compatibility
– Companies are certified to take single point responsibility for the design, installation and commissioning of fire detection and alarm systems.
The fire suppression products, systems and services certified by LPCB include:
– Automatic sprinkler, watermist, waterspray and deluge systems
– Fixed fire fighting systems (gaseous and kitchen systems)
– Companies approved for the design, installation, service and maintenance of sprinkler systems and fixed firefighting systems.
The standards used by LPCB for certifying and listing components have been developed to ensure that the components are suitable for use in systems installed to the LPC Sprinkler Rules (incorporating EN 12845). Components may also be suitable for use in installations designed to NFPA and other international and national sprinkler installation codes.
For over a hundred years sprinklers have protected people and property all over the world. Application of sprinkler installation codes which have been developed over the years have ensured high levels of fire protection.
Fire suppression products, systems and servicesKey standard Description
LPS 1036 Automatic fire sprinklers
LPS 1039 Automatic sprinklers
LPS 1040 Wet alarm valve sets
LPS 1041 Dry pipe valve sets
LPS 1045 Direct reading flow meters
LPS 1048 Sprinkler system contractors in the UK and Ireland
LPS 1131 Automatic sprinkler installation pump sets
LPS 1148Contractors engaged in the design installation, commissioning and servicing of automatic sprinkler systems
LPS 1185 Remote monitored gear operated butterfly stop valves
LPS 1186 Check valves
LPS 1194 Pipe hangers
LPS 1204Firms engaged in the design, installation and commissioning of gas extinguishing systems
LPS 1219 Pipe couplings
LPS 1223 Fixed fire extinguishing systems for catering equipment
LPS 1230 Fixed gaseous fire extinguishing systems
LPS 1236Control panels for diesel engine driven pumps used in automatic sprinkler installations
LPS 1237Control panels for electric motor driven pumps used in automatic sprinkler installations
LPS 1239 Diesel engines for sprinkler pump sets
LPS 1240Fire sprinkler pump sets used in automatic sprinkler installations
LPS 1254 Suction tanks for automatic pumps
LPS 1258Automatic sprinkler glass bulbs with a narrow operating temperature band
LPS 1260 Automatic sprinkler systems
LPS 1261 Flexible hoses for sprinkler systems
LPS 1276 Above ground suction tanks for sprinkler systems
LPS 1283Watermist systems for use in commercial low hazard occupancies
LPS 1301Sprinkler installers in the UK and Ireland for residential and domestic sprinkler systems
EN 12094Series of fixed fire-fighting systems. Components for gas extinguishing systems
EN 12259Series of fixed fire-fighting systems. Components for sprinkler and water spray systems
5
Fire suppression products, systems and services
Security protection products certified by LPCB include:
LPCB works closely with insurers, government, police, designers, manufacturers, contractors and end users to develop methods of assessing the performance and reliability of security products to ensure their fitness for purpose. Loss Prevention Standard, LPS 1175, is one of the key security standards in use.
LPCB also issue certification against a number of British (BS), European (EN) and Publicly Available Standards (PAS).
– Access covers and latches
– Alarm transmission equipment
– Cabinets and enclosures
– Cladding and roofing systems
– Doors and shutters
– Fences and walls
– Grilles and barsets
– Intrusion detection
– Locks and padlocks
– Safes and strongrooms
– Sheds and tool stores
– Vehicle barriers
– Windows and rooflights
The correct specification of certified security products and systems is critical to protecting people and property from the losses associated with crime and terrorism.
6
Security protection products and systems
Physical and electronic security products and systemsKey standards Description
LPS 1175Intruder resistant building components, strongpoints, security enclosures and freestanding barriers offering resistance to manual forced entry
LPS 1183 Safe storage units
LPS 1214Physical protection devices for personal computers and similar equipment
LPS 1224 Secure database registers
LPS 1225 Asset marking systems
LPS 1228 Office furniture – lightweight containers
LPS 1242 Cylinders for locks
LPS 1270 Intruder resistant security glazing units
LPS 1277Supervised Premises Transceivers: Intrusion and Hold-up Alarm systems
LPS 1650 ‘Theft resistant’ electronic products
LPS 1654 Padlocks
LPS 2081Building components, strongpoints, security enclosures and free-standing barriers offering resistance to intruders attempting to use stealth to gain entry
BS 7558 Gun cabinets
EN 1063 Bullet resistant glazing
EN 1143 Series
Safes, strongroom doors and strongrooms
EN 1522 Bullet resistant windows, doors, shutters and blinds
EN 1627Burglar resistant pedestrian doorsets, windows, curtain walling, grilles and shutters
EN 13123 Series
Explosion resistant windows, doors and shutters
EN 13541 Explosion resistant security glazing
EN 14450 Secure safe cabinets
EN 50131 Series
Intrusion and hold-up systems and associated components
EN 50136-2 & 3Supervised premises transceivers (SPT) and receiving centre transceivers (RCT)
EN 60839-11-1Electronic access control systems and associated components
ISO 16935 Bullet resistant security glazing
IWA14 Vehicle security barrier systems
PAS 24Doorsets and windows intended to offer a level of security suitable for dwellings and other buildings exposed to comparable risk in the UK
PAS 68 Vehicle security barrier systems
LPCB offers certification of the following manual fire extinguishing equipment:
– Portable fire extinguishers
– Hose reels
– Fire blankets
– Hydrant systems
– Wet landing valves
– Inlet breechings
– Semi rigid hoses
– Lay flat hoses
– Boxes for dry riser inlets
– Gate valves
– Hand held branchpipes
– Mobile fire extinguishers
Whether it is a portable or fixed manual fire fighting system, it is important to use the right type of equipment, which must be clearly and correctly marked, to be confident that it will meet the rigorous requirements necessary for safe and reliable use. Certification by LPCB ensures that manual fire extinguishing equipment meets the requirements of the appropriate standards.
7
Manual fire extinguishing equipment
Standards TableKey standard Description
BS 336Specification for fire hose couplings and ancillary equipment
BS 750Specification for underground fire hydrants and surface box frames and covers
BS 5041-1Fire hydrant systems equipment. Specification for landing valves for wet risers
BS 5041-2Fire hydrant systems equipment. Specification for landing valves for dry risers
BS 5041-3Fire hydrant systems equipment. Specification for inlet breechings for dry riser inlets
BS 5041-5Fire hydrant systems equipment. Specification for boxes for foam inlets and dry riser inlets
BS 5154Specification for copper alloy globe, globe stop and check, check and gate valves
BS 6165Specification for small disposable fire extinguishers of the aerosol type
BS 6391Requirements for non-percolating layflat delivery hoses and hose assemblies for fire fighting purposes.
EN 3-7Portable fire extinguishers. Characteristics, performance requirements and test methods
EN 3-8
Portable fire extinguishers. Additional requirements to EN 3-7 for the construction, resistance to pressure and mechanical tests for extinguishers with a maximum allowable pressure equal to or lower than 30 bar
EN 3-9Portable fire extinguishers. Additional requirements to EN 3-7 for pressure resistance of CO2 extinguishers
EN 3-10Portable fire extinguishers. Provisions for evaluating the conformity of a portable fire extinguisher to EN 3-7
EN 671-1Fixed firefighting systems – Hose systems. Hose reels with semi-rigid hose
EN 671-2Fixed firefighting systems – Hose systems. Hose systems with lay-flat hose
EN 694Requirements for Fire-fighting hoses – semi-rigid hoses for fixed systems
EN 14384 Pillar fire hydrants
EN 1866-1 Mobile fire extinguishers
EN 1869 Fire blankets
EN 15182-1Hand-held branchpipes for fire service use. Common requirements
EN 15182-2Hand-held branchpipes for fire service use. Combination branchpipes PN16
EN 15182-3Hand-held branchpipes for fire service use. Smooth bore jet and/or one fixed spray jet angle branchpipes PN16
EN 15182-4Hand-held branchpipes for fire service use. High pressure branchpipes PN40
1153
10 ©
BRE
012
0
About BRE
BRE Group
BRE is an international, multi-disciplinary, building science organisation with a mission to improve buildings and infrastructure through research and knowledge generation, and their application. BRE employs over 600 people in the UK, China, India, the Middle East and the USA who are committed to building a better world together.
Our products, services, standards and qualifications are applied in over 80 countries enabling our customers to make a positive difference to the built environment. We are owned by a charity called the BRE Trust, which delivers one of the largest programmes of built environment education and research for the public good.
BRE Global
BRE Global Limited (incorporating LPCB & BREEAM) is an independent third party certification body for fire, security and sustainability products and services in an international market. BRE Global’s product testing and certifications are carried out by recognised experts in our world renowned testing laboratories. BRE Global Limited is custodian of a number of world leading brands including:
– LPCB for the certification of fire and security products and services, listed on www.rebooklive.com.
– BREEAM the world’s leading environmental assessment method for buildings, sets the standard for best practice in sustainable design and has become the de-facto measure of a building’s environmental performance. All of our environmental certifications are listed on www.greenbooklive.com.
– SABRE is a security assessment and certification scheme for buildings, infrastructure and managed space.
BRE Watford, UK WD25 9XX
+44 (0)333 321 88 11 enquiries@bregroup.com
www.redbooklive.com www.bregroup.com
BRE Global Ireland
DCU Alpha Old Finglas Road Glasnevin Dublin, D11 KXN4
+353 1 882 4344 enquiries@breglobalireland.ie
BRE Global Assurance (Ireland) Ltd
BRE Global Assurance (Ireland) Ltd (BRE Global Ireland) has been established as a company based in Dublin which offers certification services to our customers to enable them to comply with European requirements.
BRE Global Ireland is a Notified Body (number 2831) and a Technical Assessment Body that can offer services in support of the Construction Products Regulation (CPR), Marine Equipment Directive (MED) and Transportable Pressure Equipment Directive (TPED).