Fluoroscopic kinematography. Technical background and ...Bi-planar, high-powered X-ray. FluoKin.de...

Post on 08-Aug-2020

2 views 0 download

transcript

Fluoroscopic kinematography: Technical background and

potential applications

Peter Böttcher Prof. Dr. med. vet., Dipl. ECVS

www.fluokin.de

FluoKin.de

Kinematics vs. kinetics

• Kinematics = motion

• Kinetics = forces

FluoKin.de

Common approaches in-vivo

• Force plate

Tepic 2007

FluoKin.de

Common approaches in-vivo

• Kinematography

Clements et al. 2005

FluoKin.de

Video based 3D-gait analysis

Dogs in Motion, Martin S. Fischer & Karin E.Lilje

FluoKin.de

Skin movement

Dogs in Motion, Martin S. Fischer & Karin E.Lilje

FluoKin.de

Skin movement

FluoKin.de

Skin Movement

FluoKin.de

Non-invasive estimation of kinematics in-vivo

• Video-analysisa c

“The large soft-tissue artefacts when using clustered skin markers, irrespective of the fixation method, question the usefulness of parameters found with external movement registration and clinical interpretation of stair data in small patient groups”.

Garling et al. Journal of Biomechanics (2007)

FluoKin.de

Why do we need more detail?• Pathologies with low range of motion

• Contact Analysis– Restoration of normal contact mechanics?

FluoKin.de

Prof. Martin S. Fischer, Institut für Spezielle Zoologie und Evolutionsbiologie, Jena, Germany

FluoKin.de

Complex Skeletal Animation

Dogs in Motion, Martin S. Fischer & Karin E.Lilje

FluoKin.de

Musculo-Skeletal Animation

Dogs in Motion, Martin S. Fischer & Karin E.Lilje

FluoKin.de

Uniplanar Fluoroscopy

• 1.5 y, Rottweiler• Lameness left hind leg, knee stable on palpation

FluoKin.de

C-Arm + Videocamera

FluoKin.de

Uni-planar, C-Arm

FluoKin.de

Fluoroscopic kinematography

= Shadow theatre

FluoKin.de

Image Undistortion

FluoKin.de

Image Calibration

FluoKin.de

www.xromm.org

FluoKin.de

3D Animation

With markers• Tantalum beads

0.5-1.0 mm Ø• Precision: 0.064 mm*

Without markers• 2D to 3D image registration• Tracking of anatomical

features (bone shape)• Precision: 0.77 mm#

Invasive Non invasive

*Tashman et al. 2003 *Rey et al. 2009

FluoKin.de

3D-2D-image registration

Fluoroscopic video sequence

Digital reconstructed radiograph (DRR)

FluoKin.de

Optimisation

Intelligent form of trial & error

FluoKin.de

Find the optimal match

FluoKin.de

Automatic tracking

FluoKin.de

Final 3D Animation

FluoKin.de

Scientific Rotoscoping

Xromm.org

FluoKin.de

Free Software

• XROMM (Brown University)

– Marker-based– Rotoscoping– AutoScoper

• JointTrack(Florida)

FluoKin.de

Accuracy with uni-planar• Left tibia• Known translation• CT-Data (0.5 mm slice thickness)• Fluo: 576x768 (0.54mm2)

• Focal distance 90 cm

Iopollo et al. Journal of Biome-chanics (2007)

FluoKin.de

Results

• Cranio-caudal translation

• Mean error: 0.31 mm

0

1

2

3

4

5

61

2

3

4

5

67

8

9

10

11

Fluo

DRR

FluoKin.de

Results

• Medio-lateral translation (in-plane)

• Mean error: 4.58 mm

6065707580859095

100105110115120125130 2

3

4

5

6

7

810

11

12

13

14

15

16

Fluo

DRR

FluoKin.de

Stereo = 3D = High accuracy

FluoKin.de

Bi-planar, high-powered X-ray

FluoKin.de

Final 3D-Animation

Xromm.org

FluoKin.de

Bone embedded coordinate system

FluoKin.de

Contact Analysis

FluoKin.de

Current Projects

• Stifle

• Elbow

• Shoulder

FluoKin.de

Other applications

FluoKin.de

Other applications

FluoKin.de

Other applications

Brown University

FluoKin.de

Other applications

Source unknown

FluoKin.de

www.fluokin.de