GE Circuit Breakers and Disconnects
Type THLC Current Limiting Circuit BreakersUnfused
15-400 Amperes200,000 AIC at 240 Volts ac Max.200,000 AIC at 480 Volts ac Max.
50,000 AIC at 600 Volts ac Max.
Type THLC1
Internal Accessories forTHLC1Same as Type TEDaccessories. Refer to pages16-19 to 16-32.
Type THLC2
Type THLC115-150 AmpsNoninterchangeable TripIncludes Line and Load Lugs
Type THLC4
AmpereRating
152030405060708090
100125150
3-PoleCatalog Number
THLC136015WL ®THLC136020WL ®THLC136030WL ®THLC136040WL ®THLC136050WL ®THLC136060WLTHLC136070WLTHLC136080WLTHLC136090WL
THLC136100WLTHLC136125WLTHLC 1 361 50WL
List Price,GO-1358
$1938.001938.001938.001938.001938.001938.001938.001938.001938.00
1938.003674.003674.00
Cu-AILug
TCAL12
TCAL12A
TCAL15
WireRange
#14-3 Cu,12-1 Al
6-2/0 Cu,4-2/0 Al
#3-3/0 Cu,1/0-3/0 Al
Internal Accessories forTHLC2 and THLC4Same as Type TFKaccessories. @ Refer to pages16-19to16-32.
Type THLC2125-225 AmpsNoninterchangeable TripIncludes Line and Load Lugs
AmpereRating
125150175200225
Adjustable TripRange Amps
Low
550675775900
1000
High
1250150017502000
' 2500
3-PoleCatalog Number
THLC236125WLTHLC236150WLTHLC236175WLTHLC236200WLTHLC236225WL
List Price,GO-135B
$3689.003689.003689.003689.003689.00
Cu-AILug
TCAL27
WireRange
#4-300 komil
TypeTHLC4250-400 AmpsNoninterchangeable TripWithout Line and Load Lugs®
AmpereRating
250300350400
Adjustable Trip RangeAmps
Low
1175140016501875
High
2500300035004000
3-PoleCatalog Number
THLC436250THLC436300THLC436350THLC436400
List Price,GO-135B
$4967.004967.004967.004967.00
Type TLB4250-400 Amps65 kA at 480 Volts ac85 kA at 240 Volts ac
Without Line and Load Lugs©
AmpereRating
250300350400
Adjustable Trip RangeAmps
Low
1175140016501875
High
2500300035004000
3-PoieCatalog Number
TLB434250TLB434300TLB434350TLB434400
List Price,GO-135B
$4278.004278.004278.004278.00
UjUSujp§8KM33§1"•*
CO® 15-50A rated 200KA at 240 Vac
and150kAat480 Vacmaximum.
© Accessory must have codedate 535+or later.
Lug kit for THLC4 or TLB4—forline or load end. Order CatalogNumber TCLK43, List Price$49.00, GO-135B. Consists ofthree-pole assembly. Wirerange (1) 3/0-500 kcmil or (2)3/0-250 kcmil Cu-AI.
Prices and data subject to change without notice 1999 Issue 16-13
Gf Circuit Breakers and Disconnects
Section 16
Spectra RMS™ Molded Case Circuit BreakersFeaturesSE150, SF250, SG600 and SK1200 circuit breaker frames have adigital solid state, rms sensing trip system with field installable,front-mounted rating plugs to establish or change the breakerampere rating Adjustable instantaneous with tracking short-timeis standard on all frames including SE150
A complete circuit breaker consists of a UL listed circuit breakerframe and a rating plug (UL listed interchangeable trip unit)Terminal lugs for cable connection are available if required
• All frames use the same UL listed field-installable internalaccessories (auxiliary switch shunt trip undervoltage release,and bell alarm)
• All frame sizes have maximum UL listed interrupting ratings of200 kA @ 240 volts ac and 100 kA @ 480 volts ac with 600 voltsac ratings to 65 kA depending on frame size UL listed currentlimiting versions are provided through the SG600 frame for the65 kA @ 480 volts ac and the 100 kA @ 480 volts ac modelswith no increase in physical frame size
• Spectra RMS Mag-Break* instantaneous-only motor circuitprotectors also use the same digital, solid-state trip unit andrating plugs as the circuit breakers The interchangeable ratingplug establishes the instantaneous pickup range (with trackingshort-time) but does not change the frame ampere rating
• Spectra RMS molded case switches have a fixed, high-setinstantaneous trip (without tracking short-time function) andhave short circuit withstand ratings equal to their equivalentbreaker frame size interrupting rating in most cases
• Spectra RMS breakers are ambient insensitive Trip times will notvary over the range 10-50°C breaker ambient Refer to GET-7002for further application information
• Spectra RMS breakers contain no parts that would supportfungus growth and are therefore inherently fungusproof
Other MCCB Features• Broad product line to meet virtually any application need• Reduced downtime A tripped breaker is easily spotted and can
be immediately reset after the fault has been corrected• Eliminates single phasing A common trip bar disconnects all
poles simultaneously on both overloads and short circuits• Offers application flexibility through the use of a wide variety of
accessory devices and special attachments• Repetitive operation—no fuses to replace• Breakers can be repetitively tested Fuses must be destroyed to
confirm calibration accuracy
For more information on GE Disconnects and Circuit Breakerssee Publication Index Section 18
Fusible SwitchesNonfusible Switches
16-216-2
Type FD1 Fusible Disconnect Switches 16-3 16-4DILOS Nonfusible Disconnect Switches 16-5,16-6Molded Case Circuit Breakers 16-7 to 16-18Accessories and Modifications 16-19 to 16-32V-Line™ Miniature Circuit Breakers 16-33 to 16-36
1999 Issue 16-1