Post on 22-Dec-2021
transcript
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A0.1
LEGE
NDS
AND
NOTE
S
SAB
101
OFFICE
A6.1
1
3
4 2
1
A8.2
1
A4.1
KEYNOTE
DETAIL
DOOR NUMBER
BUILDING
SECTION
NORTH
ARROW
ROOM NUMBER
ROOM NAME
INDICATES DIRECTION TO TRUE NORTH
DIRECTION OF SECTION
NUMBER OF SECTION
SHEET NUMBER WHERE SECTION IS LOCATED
NUMBER OF DETAIL
SHEET NUMBER WHERE DETAIL IS LOCATED
DIRECTION OF ELEVATION
NUMBER OF DRAWING ELEVATION
SHEET NUMBER WHERE ELEV. IS LOCATED
SAND/MORTAR/
PLASTER/CUT STONE
ACOUSTICAL TILE
CERAMIC TILE
GLASS
ALUMINUM
STEEL/
OTHER METALS
MARBLE
PLYWOOD
WOOD (FINISHED)
WOOD (ROUGH)
GYPSUM BOARD
EARTH
CONCRETE
BRICK
101
CONCRETE MASONRY
UNIT (CMU)
INSULATION - BATT
INSULATION - RIGID
INSULATION - SOUND
GENERAL LEGENDMATERIAL DESIGNATIONS
REFERENCE SYMBOLS
ROOM
WALL
SECTION
DIRECTION OF SECTION
NUMBER OF SECTION
SHEET NUMBER WHERE SECTION IS LOCATED
1
A4.1
1
A4.1
EXTERIOR
ELEVATION
NUMBER OF SECTION
SHEET NUMBER WHERE ELEVATION IS LOCATED
INTERIOR
ELEVATION
PARTITION TYPE
REVISION
WINDOW OR LOUVER
CEILING HEIGHT
TOILET & BATH
ACCESSORY
1
A
TBA-1
INDICATES DIRECTION TO PROJECT NORTH
+9'-0"
A1
A. ALL DIMENSIONS ARE MEASURED TO FACE OF NEW METAL STUD OR
FINISH FACE OF EXISTING GYPSUM WALLBOARD UNLESS NOTED
OTHERWISE.
B. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT FOR ANY MISSING
DIMENSIONS.
C. REFER TO SHEET G0.3 FOR DEFINITION OF ABBREVIATIONS.
D. REFER TO LIFE SAFETY PLANS FOR LOCATIONS OF ALL
FIRE-RESISTANCE-RATED AND SMOKE-RESISTANT PARTITIONS.
E. SEE DETAIL 1/A12.1 FOR TYPICAL FIRE EXTINGUISHER CABINET DETAIL.
F. SEE DETAIL 3/A12.1 FOR TYPICAL FIRE EXTINGUISHER MOUNTING
BRACKET DETAIL.
G. PROVIDE WALL-MOUNTED ACCESS DOORS WHEREVER ACCESS IS
REQUIRED TO CONCEALED MECHANICAL, ELECTRICAL, PLUMBING, AND
FIRE PROTECTION SYSTEMS. SEE DETAIL 5/A12.1 FOR TYPICAL ACCESS
DOOR LOCATED IN GYPSUM WALLBOARD PARTITION.
H. ALL COPIERS, REFRIGERATORS, AND TELEVISIONS INDICATED ON NEW
FLOOR PLANS ARE NOT IN CONTRACT AND WILL BE PROVIDED BY
OWNER.
I. REFER TO SHEET A4.1 FOR INTERIOR PARTITION NOTES AND DETAILS.
J. WHERE THE 1ST FLOOR SLAB HAS BEEN SELECTIVELY DEMOLISHED TO
ACCOMMODATE NEW PLUMBING PIPING, REPLACE REMOVED SECTIONS
OF FLOOR SLAB WITH 4,000 PSI CONCRETE ON NEW VAPOR RETARDER
AFTER PIPE INSTALLATION IS COMPLETE. IF PORTION OF REMOVED SLAB
IS A LONG NARROW TRENCH, REINFORCE CONCRETE WITH (2) #3 REBAR
PARALLEL TO THE PIPE DIRECTION AND WITH #3 REBAR AT 1'-4" O.C.
TRANSVERSE TO THE PIPE DIRECTION. TRANSVERSE REINFORCEMENT
SHALL BE SET IN 4" DEEP HOLES DRILLED IN CENTER OF EXISTING SLAB
WITH HILTI HIT-HY 200 ADHESIVE OR EQUIVALENT. STAGGER EMBEDDED
END OF TRANSVERSE REINFORCEMENT AND PROVIDE 90-DEGREE HOOK
AT END OF REBAR TERMINATING IN NEW CONCRETE. IF PORTION OF
REMOVED SLAB IS LIMITED TO AN AREA IN A ROOM, REINFORCE NEW
CONCRETE WITH #3 REBAR AT 1'-4" ON CENTER IN EACH DIRECTION.
REINFORCEMENT SHALL BE SET IN 4" DEEP HOLES DRILLED IN CENTER
OF EXISTING SLAB WITH HILTI HIT-HY 200 ADHESIVE OR EQUIVALENT.
STAGGER EMBEDDED END OF REINFORCEMENT AND PROVIDE
90-DEGREE HOOK AT END OF REBAR TERMINATING IN NEW CONCRETE.
1. ALIGN CENTERLINE OF NEW PARTITION WITH CENTER OF EXISTING WALL
FURRING AT STRUCTURAL COLUMN, TYPICAL.
2. ALIGN CENTERLINE OF NEW PARTITION ON CENTER OF EXISTING WALL
BETWEEN WINDOW JAMBS.
3. ALIGN FINISH FACE OF NEW PARTITION WITH FINISH FACE OF EXISTING
PARTITION OR FURRING.
4. FURR-OUT EXISTING MASONRY WALL WITH 25 GAUGE 3 5/8" METAL
STUDS AT 16" O.C. MAX WITH 5/8" GYPSUM WALLBOARD FINISH.
5. LOCATE NEW PARTITION AS CLOSE AS POSSIBLE TO SOUTH END OF
EXISTING WALL-MOUNTED EXHAUST DUCT.
6. FURR-OUT EXISTING PARTITION WITH 25 GAUGE 1-5/8" METAL STUDS AT
16" O.C. MAX. WITH 5/8" GYPSUM WALLBOARD FINISH.
7. ALIGN CENTERLINE OF PARTITION WITH CENTERLINE OF WINDOW
MULLION.
8. ALIGN FINISH FACE OF PARTITION WITH EXISTING VERTICAL FACE OF
GYPSUM WALLBOARD SOFFIT OR WALL ABOVE.
9. FURR-OUT WALL WITH 25 GAUGE METAL STUDS AND 5/8" GYPSUM
WALLBOARD AS REQUIRED TO ALIGN AND MATCH BUMP OUT AT MEN 107.
10. FURR-OUT WALL AS REQUIRED TO PROVIDE A CONTINUOUS GYPSUM
WALLBOARD FINISH ACROSS THE FULL LENGTH OF THE WALL.
11. SEE INTERIOR ELEVATIONS FOR WOOD-FRAMED WINDOWS LOCATED IN
UPPER PORTION OF PARTITION.
12. NEW QUARTZ COUNTERTOP WITH BACK AND SIDE SPLASHES.
13. RELOCATED EXISTING AUTOMATED EXTERNAL DEFIBRILLATOR (AED).
14. ALIGN END OF WALL WITH EDGE OF SOFFIT ABOVE.
15. EXISTING MARKER BOARD (RELOCATED).
16. ALIGN PARTITION WITH BORROWED LITES.
17. PARTIAL-HEIGHT PARTITION. ALIGN TOP OF PARTITION WITH SILL OF
INTERIOR BORROWED LITES AT CORRIDOR (APPROX. 7-3 1/2" A.F.F.).
18. PROVIDE MOP AND BROOM HOLDER EQUAL TO BOBRICK MODEL B-224 X
36. MOUNT TOP OF SHELF AT 60" ABOVE FINISH FLOOR AND LOCATE ON
SOUTH WALL ABOVE MOP BASIN.
FLOOR PLAN KEY NOTES
FLOOR PLAN GENERAL NOTES
CJ
ACOUSTICAL CEILING PANELS W/ SUSPENDED GRID SYSTEM
GYPSUM WALLBOARD FINISH
2' X 2' RECESSED FLUORESCENT LIGHT
PENDANT-MOUNT LINEAR FLUORESCENT LIGHT
1' X 4' INDUSTRIAL FLUORESCENT LIGHT
PENDANT LIGHT
ROUND RECESSED DOWNLIGHT
WALL-MOUNTED LIGHT
WALL-MOUNTED LINEAR FLUORESCENT LIGHT
EXIT SIGN (1-SIDED)
EXIT SIGN (2-SIDED)
PROJECTOR WITH LAY-IN CEILING MOUNT KIT
OCCUPANCY SENSOR
SMOKE DETECTOR
SECURITY CAMERA
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
CEILING ACCESS PANEL
CONTROL JOINT
EXPOSED TO STRUCTURE
GYPSUM WALLBOARD
GYPSUM WALLBOARD HEADER
GYPSUM WALLBOARD SOFFIT
SPRINKLER - PENDANT
SPRINKER - CONCEALED PENDANT
SPRINKLER - UPRIGHT
EXP
OC
SD
GWB
GWH
P
REFLECTED CEILING PLAN LEGEND
REFLECTED CEILING PLAN GEN. NOTESA. SHADED AREAS ON REFLECTED CEILING PLAN INDICATES EXISTING
CONDITIONS TO REMAIN.
B. PROVIDE CEILING ACCESS DOORS WHEREVER ACCESS IS REQUIRED TO
CONCEALED MECHANICAL, ELECTRICAL, PLUMBING AND FIRE
PROTECTION SYSTEMS (E.G. ISOLATION VALVES, HAMMER ARRESTORS,
VAV BOXES, DAMPERS, SHUT-OFF SWITCHES). COORDINATE ACCESS
DOOR LOCATIONS AND SIZES WITH ARCHITECT PRIOR TO INSTALLATION.
SEE DETAIL 4/A12.1 FOR TYPICAL ACCESS DOOR LOCATED IN GYPSUM
WALLBOARD CEILING.
C. REFER TO FINISH SCHEDULE ON SHEETS A9.1 FOR FINISH CEILING
HEIGHTS UNLESS INDICATED OTHERWISE.
REFLECTED CEILING PLAN KEY NOTES1. ALIGN BOTTOM OF GYPSUM WALLBOARD SOFFIT WITH HEAD OF EXISTING
INTERIOR WINDOWS.
2. GYPSUM WALLBOARD HEADER OR SOFFIT AT 6'-10" A.F.F.
GWS
FLOOR PLAN LEGENDEXISTING WALL OR PARTITION
NEW METAL STUD PARTITION
EXISTING DOOR & FRAME
NEW DOOR & FRAME
1
DEMOLITION PLAN KEY NOTES
DEMOLITION PLAN GENERAL NOTES
DEMOLITION PLAN LEGENDEXISTING WALL OR PARTITION TO REMAIN
EXISTING WALL OR PARTITION TO BE REMOVED
EXISTING DOOR & FRAME TO REMAIN
EXISTING DOOR & FRAME TO BE REMOVED
1. DISMANTLE AND DISPOSE OF EXIST. FOLDING PANEL PARTITION,
OVERHEAD TRACK, AND JAMBS.
2. SELECTIVELY DEMO THE PORTION OF THE EXIST. GYPSUM WALLBOARD
METAL-FRAMED SOFFIT THAT PROJECTS DOWN PAST THE HEAD OF THE
INTERIOR WINDOWS LOCATED ALONG THE SOUTH WALL OF THE
TRAINING ROOM.
3. DEMO THE EXISTING W12X14 FOLDING PANEL PARTITION STRUCTURAL
SUPPORT BEAM.
4. REMOVE AND RELOCATE EXISTING FIRE EXTINGUISHER CABINET. SEE
SHEET A1.1 FOR NEW LOCATION.
5. REMOVE AND RELOCATE EXISTING MARKER BOARD TO NEW EAST WALL
OF TRAINING ROOM 156.
6. DEMO EXISTING ALUMINUM-FRAMED ENTRANCE DOOR AND SIDELIGHT.
7. REMOVE AND RELOCATE EXISTING BULLETIN BOARD CABINET. VERIFY
NEW LOCATION WITH OWNER.
8. REMOVE AND RELOCATE EXISTING MARKER BOARD. VERIFY NEW
LOCATION WITH OWNER.
9. REMOVE AND RELOCATE EXISTING WALL-MOUNTED MAP. VERIFY NEW
LOCATION WITH OWNER.
10. DEMO EXISTING INTERIOR WINDOWS AT ROOMS 222, 240 AND 2011 AND
INFILL OPENINGS WITH NEW METAL STUD FRAMING AND GYPSUM
WALLBOARD AS REQUIRED. (NOT APPLICABLE)
11. REMOVE AND SALVAGE EXISTING TELEVISION AND WALL BRACKET.
12. REMOVE EXISTING DOOR AND REPLACE WITH NEW. EXISTING HOLLOW
METAL DOOR FRAME TO REMAIN.
13. REMOVE EXISTING WALLCOVERING FROM NORTH, WEST AND SOUTH
WALLS ADJACENT TO ELEVATOR SHAFT AND PATCH AND REPAIR
GYPSUM WALLBOARD TO RECEIVE NEW PAINT FINISH.
14. REMOVE PORTIONS OF EXISTING 1ST FLOOR SLAB AS REQUIRED TO
INSTALL NEW PLUMBING SANITARY PIPING. AFTER PIPE INSTALLATION,
REFER TO FLOOR PLAN GENERAL NOTE J.
15. REMOVE EXISTING COUNTERTOP AND REPLACE WITH NEW QUARTZ
COUNTERTOP WITH BACKSPLASH.
16. DEMO EXISTING WALL-MOUNTED LIGHT FIXTURE.
17. REMOVE AND RELOCATE EXISTING AUTOMATED EXTERNAL
DEFIBRILLATOR TO FOYER 104. SEE SHEET A1.1 FOR NEW LOCATION.
18. REMOVE AND RELOCATE EXISTING WALL-MOUNTED CLOCK. COORDINATE
NEW LOCATION WITH OWNER.
19. DEMO EXISTING WALL-MOUNTED LIGHT FIXTURE(S) AND PATCH AND
REPAIR GYPSUM BOARD AS REQUIRED TO LEAVE NO VISIBLE EVIDENCE
THAT LIGHT FIXTURES WERE EVER THERE.
A. REFER TO SPECIFICATION SECTION 02 41 19 SELECTIVE DEMOLITION FOR
APPLICABLE REQUIREMENTS.
B. ALL EXISTING WOOD DOORS AND HOLLOW METAL FRAMES INDICATED TO
BE REMOVED SHALL BE SALVAGED AND REUSED TO THE MAXIMUM
EXTENT POSSIBLE.
C. DEMO ALL EXISTING PAINTED WOOD TRIM LOCATED AT APPROXIMATELY
6'-10" A.F.F. PATCH AND REPAIR GYPSUM WALLBOARD WHERE EXISTING
PARTITIONS ARE INDICATED TO REMAIN. IN THOSE LOCATIONS WHERE
FIRE ALARM DEVICES ARE MOUNTED ON THE WOOD TRIM, REWORK
ELECTRICAL CONNECTIONS SO THAT THE BACK OF THE FIRE ALARM
DEVICES WILL SIT FLUSH AGAINST THE GYPSUM WALLBOARD FINISH.
D. DEMO THE EXISTING STAINED WOOD CHAIR RAIL IN EXISTING TRAINING
ROOM 173 AND THEN PATCH AND REPAIR GYPSUM WALLBOARD.
E. THE EXISTING CONSTRUCTION FOR THE 2ND AND 3RD FLOOR DECKS IS
A 2" CONCRETE TOPPING WITH 6X6 - W1.4 X W1.4 WELDED WIRE MESH ON
12" PRE-STRESSED HOLLOW CORE PLANKS. PRIOR TO MAKING ANY
PENETRATIONS THROUGH EITHER DECK, THE CONTRACTOR SHALL HIRE
A TESTING AGENCY TO FIELD LOCATE THE PRE-STRESSED STRANDS IN
THE HOLLOW CORE PLANKS IN THE VICINITY OF THE PROPOSED
PENETRATIONS. IF ANY PRE-STRESSED STRANDS ARE DETERMINED TO
BE IN THE WAY OF A PROPOSED PENETRATION, IMMEDIATELY NOTIFY
THE ARCHITECT. PLEASE NOTE THAT THE TESTING AGENCY'S FIELD
LOCATION RESULTS MUST BE PROVIDED TO THE ARCHITECT PRIOR TO
THE INSTALLATION OF ANY INTERIOR PARTITION FRAMING. THE
CONTRACTOR SHALL AVOID CUTTING OR DRILLING INTO OR THROUGH
ANY OF THE PRE-STRESSED STRANDS. IF THAT SHOULD OCCUR, STOP
WORK AND IMMEDIATELY NOTIFY THE OWNER AND ARCHITECT.
4 5 6 7 8
A
B
C
D
4 5 76 8
SCALE:
1ST FLOOR PHASING PLAN - PHASE 11/8" = 1'-0"
UP
REF
ICE
3'-8"
4'-0"
2
1
3
NOTE: SHADING INDICATES AREA TO BE RENOVATED IN PHASE 2.
9'-0
"
1
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A0.2
1ST
FLOO
R PH
ASIN
G PL
AN -
PHAS
E 1
SAB
SCALE: 1/8" = 1'
0 8' 16'4'
GENERAL PHASING NOTESA. THE RENOVATION OF THE 1ST FLOOR SHALL OCCUR IN TWO
PHASES: SHEET A0.2 INDICATES THE EXISTING AREA TO BE
RENOVATED IN PHASE 1, AND SHEET A0.3 INDICATES THE
EXISTING AREA TO BE RENOVATED IN PHASE 2.
B. AT THE PRECONSTRUCTION MEETING, THE GENERAL
CONTRACTOR, OWNER AND ARCHITECT SHALL REVIEW THE
PHASING IN ORDER TO MINIMIZE THE IMPACTS TO THE
OWNER'S EXISTING OPERATIONS, TO MAINTAIN LIFE SAFETY
EGRESS, AND TO PROTECT ALL PERSONNEL AND PATRONS
DURING THE RENOVATION.
PHASE 1 KEY NOTES1. PROVIDE A TEMPORARY 7 FT. HIGH BARRICADE WITH 2X4
WOOD STUDS AT 24" O.C. WITH 1/2" PLYWOOD SHEATHING ON
ONE SIDE TO SEPARATE AREA UNDER RENOVATION FROM
AREA TO REMAIN OPERATIONAL DURING PHASE ONE. EXPOSED
SIDE OF PLYWOOD SHEATHING AND PLYWOOD EXIT DOOR TO
BE PAINTED TO MATCH EXISTING GYPSUM WALLBOARD.
2. PROVIDE A 3'-0" X 6'-8" PLYWOOD EXIT DOOR WITH
SELF-CLOSING HINGES AND NO LATCH. DOOR MUST REMAIN
UNLOCKED AT ALL TIMES IN ORDER TO MAINTAIN
UNRESTRICTED ACCESS OVER TO THE EXISTING EXTERIOR
EXIT DOORS. PROVIDE AN "EMERGENCY EXIT ONLY" SIGN ON
THE DOOR. SIGN SHALL HAVE RED LETTERS ON A WHITE
BACKGROUND. AT ALL TIMES, THE CONTRACTOR SHALL
MAINTAIN A CLEAR EGRESS PATH OF 44 INCHES FROM THE
TEMPORARY DOOR OVER TO THE EXISTING EXIT DOORS.
3. LOCATE TEMPORARY BARRICADE AS REQUIRED TO MAINTAIN
ACCESS TO EXISTING CARD READER WHILE PROVIDING
SUFFICIENT CLEARANCE TO INSTALL NEW SECURITY DESK.
1
1 2 3 4 5
A
B
C
D
2 3 4 5
SCALE:
1ST FLOOR PHASING PLAN - PHASE 21/8" = 1'-0"
ELEV
UP
UP
1
1
2
3'-0"
NOTE: SEE SHEET A0.2 FOR GENERAL PHASING NOTES.
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A0.3
1ST
FLOO
R PH
ASIN
G PL
AN -
PHAS
E 2
SAB
SCALE: 1/8" = 1'
0 8' 16'4'
PHASE 2 KEY NOTES1. PROVIDE A TEMPORARY 7 FT. HIGH BARRICADE WITH 2X4
WOOD STUDS AT 24" O.C. WITH 1/2" PLYWOOD SHEATHING ON
ONE SIDE TO SEPARATE AREA UNDER RENOVATION FROM
AREA TO REMAIN OPERATIONAL DURING PHASE TWO. EXPOSED
SIDE OF PLYWOOD SHEATHING TO BE PAINTED TO MATCH
EXISTING GYPSUM WALLBOARD.
2. CONTRACTOR TO COORDINATE REMOVAL OF EXISTING
SECURITY DESK AND INSTALLATION OF NEW QUEUING KIOSK
WITH OWNER.
1
1 2 3 4 5 6 7 8
A
B
C
D
A
B
C
D
2 3 4 5 76 8
SCALE:
EXISTING 1ST FLOOR PLAN1/8" = 1'-0"
178
STAIRS134A
STAIRS101
WAITING
100B
INFO
100A
PUBLICFOYER
102
MEETING
ELEV
100C
WAITING
103
WOMEN
104 106
105
MEN
100D
FOYER197
BREAKROOM
192
CORRIDOR
101A
COUNTERALCOVE #1
101B
COUNTERALCOVE #2
196
CORRIDOR
193
COPY
194
DEV. SER.DR.
195
DEV. SER.DR.
163
ZO(2)
173
TRAININGROOM
191
FOYER
190
SIGNS
184
SUPPLY180
HALL 189
HALL
187
PLANNINGAPP. COOR.
186
PLANNINGAPP. COOR.
185
PLANNINGENV. PLAN
REVIEW183
PLANNINGENV. PLAN
REVIEW182
ENV. PLANREVIEW
181
PLANNINGADMIN.
188
HALL
179
MECHANICALROOM
174
HALL
172
HALL
CO
FF
EE
175
JAN.
177
MEN176
WOMEN
171
COMM.ROOM
170
DEV. SERVICESZONING
169
DEV.SERVICESSUPPLY
CO
FF
EE
167
DEV. SERVICESCHIEF INSP.
165
DEV. SERVICESZONING MANAGEMENT
160
DEV. SERVICESREC. MANAGEMENT
168
HALL
166
DEV. SERV. FILES162
DEV.SERVICESAPPL. CO.
161
DEV.SERVICESAPPL. CO.
157
CORRIDOR
157
HALL164
HALL
158
DEV.SERVICES
159
DEV. SERVICESAPPL. CO. MGR.
154
ELEC.ROOM
156
CORRIDOR
155
HALL150
B.D.148
B.D.146
B.D.INST.
PLN. REV.
152
B.D.APP. COOR.
151
B.D.APP. COOR.
149
B.D.CONT. LIC.
147
B.D.CONT. LIC.
145
B.D.CONT. LIC.
143
B.D.CONT. LIC.
141
B.D.CONT. LIC.
144
B.D.INST.
PLN. REV.142
B.D.INST.
PLN. REV.140
B.D.
153
HALL
139
B.D.RECORD MGR.
138
B.D.RECORD MGR.
137
B.D.RECORD MGR.
119
HALL
119
HALL
136
B.D.135
SHOWERROOM
131
JAN.
CO
FF
EE
132
MEN133
WOMEN
120
ENV. H.LAB
118
ENV. H.DIRECTOR
116
ENV. H.ARCHIVES/
FILES114
ENV. H.FIELD WORK
112
ENV. H.FIELD WORK
110
ENV. H.107
IMAGING
117
CORRIDOR
101C
COUNTERALCOVE #3
101D
COUNTERALCOVE #4
129
CORRIDOR
109
ENV. H.FIELDWORK
111
ENV. H.FIELDWORK
113
ENV. H.FIELDWORK
115
ENV. H.FIELDWORK
128
ENV. H.FIELDWORK
126
ENV. H.FIELDWORK
124
ENV. H.FIELDWORK
122
ENV. H.FIELDWORK
123
HALL
CO
FF
EE
125
ENV. H.ARCHIVES/
CONFERENCE
121
ENV. H.EQUIP.
119A
BUILDINGFILES
127
BUILDINGFILES
130
HALL
UP
UP UP
117
ENV. H.COMM.
TV
WH
REF
REF
ICE
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
AD1.1
EXIS
TING
1ST
FLOO
R PL
AN
SAB
SCALE: 1/8" = 1'
0 8' 16'4'
NOTE: THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED
BY OTHERS AND THROUGH A LIMITED FIELD SURVEY AND MAY NOT
ACCURATELY REFLECT THE EXISTING CONDITIONS. FOR THOSE PERSONS
RELYING ON THIS DRAWING FOR ANY PURPOSE ARE ADVISED TO OBTAIN
INDEPENDENT VERIFICATION PRIOR TO PROCEEDING WITH ANY WORK.
1
1 2 3 4 5 6 7 8
A
B
C
D
A
B
C
D
2 3 4 5 76 8
SD
SD
SCALE:
EXISTING 1ST FLOOR REFLECTED CEILING PLAN1/8" = 1'-0"
ELEV
OPEN
TO ABOVE
OPEN
TO ABOVE
NOTE: REFER TO SHEET A0.1 FOR REFLECTED CEILING PLAN LEGEND.
A/C
A/C
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
AD1.2
EXIS
T. 1S
T FL
R. R
EFL.
CEI
LING
PLA
N
SAB
SCALE: 1/8" = 1'
0 8' 16'4'
NOTE: THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED
BY OTHERS AND THROUGH A LIMITED FIELD SURVEY AND MAY NOT
ACCURATELY REFLECT THE EXISTING CONDITIONS. FOR THOSE PERSONS
RELYING ON THIS DRAWING FOR ANY PURPOSE ARE ADVISED TO OBTAIN
INDEPENDENT VERIFICATION PRIOR TO PROCEEDING WITH ANY WORK.
1
1 2 3 4 5 6 7 8
A
B
C
D
A
B
C
D
2 3 4 5 76 8
SCALE:
1ST FLOOR DEMOLITION PLAN1/8" = 1'-0"
178
STAIRS134A
STAIRS101
WAITING
100B
INFO
100A
PUBLICFOYER
102
MEETING
ELEV
100C
WAITING
103
WOMEN
104 106
105
MEN
100D
FOYER197
BREAKROOM
192
CORRIDOR
101A
COUNTERALCOVE #1
101B
COUNTERALCOVE #2
196
CORRIDOR
193
COPY
194
DEV. SER.DR.
195
DEV. SER.DR.
163
ZO(2)
173
TRAININGROOM
191
FOYER
190
SIGNS
184
SUPPLY180
HALL 189
HALL
187
PLANNINGAPP. COOR.
186
PLANNINGAPP. COOR.
185
PLANNINGENV. PLAN
REVIEW183
PLANNINGENV. PLAN
REVIEW182
ENV. PLANREVIEW
181
PLANNINGADMIN.
188
HALL
179
MECHANICALROOM
174
HALL
172
HALL
CO
FF
EE
175
JAN.
177
MEN176
WOMEN
171
COMM.ROOM
170
DEV. SERVICESZONING
169
DEV.SERVICESSUPPLY
CO
FF
EE
167
DEV. SERVICESCHIEF INSP.
165
DEV. SERVICESZONING MANAGEMENT
160
DEV. SERVICESREC. MANAGEMENT
168
HALL
166
DEV. SERV. FILES162
DEV.SERVICESAPPL. CO.
161
DEV.SERVICESAPPL. CO.
157
CORRIDOR
157
HALL164
HALL
158
DEV.SERVICES
159
DEV. SERVICESAPPL. CO. MGR.
154
ELEC.ROOM
156
CORRIDOR
155
HALL150
B.D.148
B.D.146
B.D.INST.
PLN. REV.
152
B.D.APP. COOR.
151
B.D.APP. COOR.
149
B.D.CONT. LIC.
147
B.D.CONT. LIC.
145
B.D.CONT. LIC.
143
B.D.CONT. LIC.
141
B.D.CONT. LIC.
144
B.D.INST.
PLN. REV.142
B.D.INST.
PLN. REV.140
B.D.
153
HALL
139
B.D.RECORD MGR.
138
B.D.RECORD MGR.
137
B.D.RECORD MGR.
119
HALL
119
HALL
136
B.D.135
SHOWERROOM
131
JAN.
CO
FF
EE
132
MEN133
WOMEN
120
ENV. H.LAB
118
ENV. H.DIRECTOR
116
ENV. H.ARCHIVES/
FILES114
ENV. H.FIELD WORK
112
ENV. H.FIELD WORK
110
ENV. H.107
IMAGING
117
CORRIDOR
101C
COUNTERALCOVE #3
101D
COUNTERALCOVE #4
129
CORRIDOR
109
ENV. H.FIELDWORK
111
ENV. H.FIELDWORK
113
ENV. H.FIELDWORK
115
ENV. H.FIELDWORK
128
ENV. H.FIELDWORK
126
ENV. H.FIELDWORK
124
ENV. H.FIELDWORK
122
ENV. H.FIELDWORK
123
HALL
CO
FF
EE
125
ENV. H.ARCHIVES/
CONFERENCE
121
ENV. H.EQUIP.
119A
BUILDINGFILES
127
BUILDINGFILES
130
HALL
UP
UP UP
117
ENV. H.COMM.
TV
WH
REF
REF
ICE
3
2 1
4
6 6
7 8 9
11
5
NOTE: REFER TO SHEET A0.1 FOR DEMOLITION PLAN LEGEND & NOTES.
13
15
17
66
18
19
19 19
13 13
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
AD1.3
1ST
FLOO
R DE
MOLI
TION
PLA
N
SAB
SCALE: 1/8" = 1'
0 8' 16'4'
NOTE: THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED
BY OTHERS AND THROUGH A LIMITED FIELD SURVEY AND MAY NOT
ACCURATELY REFLECT THE EXISTING CONDITIONS. FOR THOSE PERSONS
RELYING ON THIS DRAWING FOR ANY PURPOSE ARE ADVISED TO OBTAIN
INDEPENDENT VERIFICATION PRIOR TO PROCEEDING WITH ANY WORK.
1
1 2 3 4 5 6 7 8
A
B
C
D
A
B
C
D
2 3 4 5 76 8
14
SCALE:
1ST FLOOR PLAN1/8" = 1'-0"
160
STAIRS125
STAIRS
105
MEETINGROOM
ELEV
104
FOYER
106
WOMEN107
MEN
156
TRAININGROOM
155
FOYER
159
MEN158
WOMEN
126
SHOWERROOM
122
JAN.
123
MEN124
WOMEN
121
CORRIDOR
UP
UP UP
161
COMM.ROOM
140
ELEC.
114
DOHIT
144
BREAKROOM
118
BREAKROOM
157
JAN.
171
STOR.
CASHIER
110
DOH
112
OFFICE
113
OFFICE
132
OFFICE133
OFFICE136
OFFICE137
OFFICE127
OFFICE
128
OFFICE130
OFFICE131
OFFICE134
OFFICE135
OFFICE138
OFFICE139
OFFICE170
OFFICE168
OFFICE166
OFFICE164
OFFICE
163
OFFICE 167
OFFICE
117
PLANROOM
148
OFFICE149
OFFICE
154
MECHANICALROOM
151
OFFICE152
OFFICE150
OFFICE147
OFFICE
143
CORRIDOR
146
CORRIDOR
165
CORRIDOR
162
CORR
IDOR
145
CORR.
153
CORR
IDOR
141
CORR
IDOR
129
CORRIDOR
108
CORRIDOR
116
CORR
IDOR
102
INTAKE103
INTAKE
NOTE: REFER TO SHEET A0.1 FOR FLOOR PLAN LEGEND & NOTES.
100
142
142
CORRIDOR
104
105
106107
109
111C
110
111
111B
112
113
114
117
119
120
122
123 124
125
125A
121
126
127
128
130131
132133
134135
136137
138139
140
143
144
147
150151
148149
152
153
154
156
157
158159
155
160
160A
162
161
163
164
156A
170168166
167
REF
REF
COPIER
REF
ICE
WH
CO
PIE
R
TV TV
FEC
FEC
FEC
FEC
EFEC
FE
C
EFE
EFE
FE
A6.3
2
4
- -
A6.3
-
-
- 7
A6.3
1
1
6 -
A6.6
5
4
- 3
A6.3
3
2
- -
A6.4
3
2
- -
A6.4
9
-
- -
A6.4
1
4
- -
A6.4
5
6
-
A6.4
7
8
- -
A6.5
-
-
- 2
A6.5
-
-
1 -
A6.4
-
-
- 10
A6.4
-
-
- 10
A6.5
5
-
4 3
A6.6
-
9
- -
A6.6
-
-
- 10
A6.6
-
-
10 -
A6.6
-
11
- -
A6.5
-
-
- 8
A6.5
-
-
6 -
A6.5
-
7
- -
2'-2"
10'-0 5/8"
4'-4"
7 7
1
5'-4 7
/8"
10'-0"
2
2'-2"
8 8
5'-4 7/8"
EQ.
4'-0 5/8"
EQ. 4'-1 1/4" EQ.
5'-0"
CLE
AR
MIN
.
5'-0"
CLE
AR
MIN
.
CO
PIE
R
CO
PIE
R
10'-0 5/8"
4'-10"
CLE
AR
MIN
.
3'-8"
41'-9 1/4"
EQ
.E
Q.
9
13'-4"
10
'-6
"
4'-0"
3'-5"
5'-0"
CLEAR
8
11'-2"11'-2"
5'-0 5/8" 10'-2" 10'-2" 10'-2"
5'-4 7/8"
EQ
.E
Q.
10 10
8
EMB
B
AC
LVT CPT
CPT CPTLVT
12
109
SCANNING
A6.6
-
-
6 -
111
OFFICE
108
108A
3'-1 1/4"
4"
COPIER
CO
PIE
R
169
OFFICE
119
STOR.
120
STOR.
117A
109A
109A
COPYROOM
COPIER
10'-5 1/4"
A6.6
-
-
7 8
A6.6
-
1
- -
111A
AL
IG
N
1'-0"
14'-6
1/4"
4'-6"
MIN
. C
LR
.
4 5/8"
SECURITY
DESK
115
CORRIDOR
169
9'-8"
3'-0"
3'-6"
3'-1"
FIN.
FIN
.F
IN
.F
IN
.
4'-0"
6 1/2"
7'-0 5/8
"
FIN.
10'-0"
13
14
A6.6
-
-
2 -
ALIGN
5'-0"
1'-0" MIN.
CLEAR.
EQ.EQ.
EQ.
171
15
18" MIN.
CLEAR.
CO
PIE
R
ALIGN
FEC
8 88 8
4'-0"
15'-6"
CLE
AR
8
1414
ALIGN
5'-1 1/4"
10'-5 1/4"
18" MIN.
CLEAR.
5'-0"
3'-1 1/4"
4"
16
16
1'-4"
2'-0"
17
17
1 3 5 7
642
15 13 11
14 12
19 17
20 18 16
9
8 10
QUEUING
KIOSK
A6.3
-
-
5 -
6'-0"
9'-6"
9'-6"
EQ
.E
Q.
8'-5" 8'-5" 8'-5" 8'-5" 8'-5"
6'-0"
EQ
.E
Q.
101
WAITING
3 EQUAL
ALIGN
9'-6"
6'-0"
9'-6"
4'-0"
9'-6"
9'-6"
OPP.
A6.4
-
-
- 10
A6.5
-
-
1 -
8'-6"
LVT
4'-1 1/4"
6"6"
17
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A1.1
1ST
FLOO
R PL
AN
SAB
SCALE: 1/8" = 1'
0 8' 16'4'
1
1 2 3 4 5 6 7 8
A
B
C
D
A
B
C
D
2 3 4 5 76 8
SD
R
SD
SCALE:
1ST FLOOR REFLECTED CELING PLAN1/8" = 1'-0"
ELEV
NOTE: REFER TO SHEET A0.1 FOR REFLECTED CEILING PLAN LEGEND.
A/C
125
101
105
104
106 107
156
155
159 158
126
122
124
121
161
140
114
144
118
156A
157
170
109
110
111
110
112
113
117
132133136137
127
128130131134135138139
164
163
168
119
120
148149
154
151152 150 147
143
146
165
162
145
153
141
129
108
116
103
142
167166 169
123
102
103
1
3
3
3
3
160
2
109A
115
+9'-0"
+9'-0"
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A1.2
1ST
FLOO
R RE
FLEC
TED
CEIL
ING
PLAN
SAB
SCALE: 1/8" = 1'
0 8' 16'4'
1
1 2 3 4 5 6 7 8
A
B
C
D
A
B
C
D
2 3 4 5 76 8
166 SQ. FT.
125 SQ. FT. 120 SQ. FT. 120 SQ. FT.
132 SQ. FT.
133 SQ. FT.
168 SQ. FT.
92 SQ. FT. 92 SQ. FT. 94 SQ. FT.
131 SQ. FT.
864 SQ. FT.
103 SQ. FT.
21 SQ. FT.
151 SQ. FT.
114 SQ. FT.
145 SQ. FT.
57 SQ. FT.431 SQ. FT.
57 SQ. FT.
108 SQ. FT. 109 SQ. FT. 109 SQ. FT. 106 SQ. FT.
163 SQ. FT.
168 SQ. FT.
95 SQ. FT.93 SQ. FT.94 SQ. FT.107 SQ. FT.108 SQ. FT.
109 SQ. FT.
162 SQ. FT.
499 SQ. FT.
527 SQ. FT.
212 SQ. FT.
357 SQ. FT.
85 SQ. FT.
102 SQ. FT.
SCALE:
1ST FLOOR FURNITURE PLAN1/8" = 1'-0"
160 125
101
105
ELEV
104
106 107
156
155
159 158
126
122
123 124
121
UP
UP UP
161
140
114
144
118
167
157
CASHIER
109
110
112
113
117
132133136137
127
128130131134135138139
166
164
163
169
119
120
148149
154
151
152
150 147
143
146
165
162
145
153
141
129
108
116
102
103
142
REF
168 170
REF
ICEREF
CO
PIE
R
TV TV
COPIER
CO
PIE
R
CO
PIE
R
COPIER
NOTE: FURNITURE IS NOT INCLUDED IN CONTRACT.
1
2
111
COPIER
CO
PIE
R
115
109A
SECURITY
DESK
171
SAFE
CO
PIE
R
EMB
1 3 5 7
642
15 13 11
14 12
19 17
20 18 16
9
8 10
QUEUING
KIOSK
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A1.3
1ST
FLOO
R FU
RNIT
URE
PLAN
SAB
SCALE: 1/8" = 1'
0 8' 16'4'
1
1 2 3 4 5 6 7 8
A
B
C
D
A
B
C
D
2 3 4 5 76 8
SCALE:
1ST FLOOR SIGNAGE PLAN1/8" = 1'-0"
ELEV
UP
UP UP
CASHIER
NOTE: REFER TO SHEET A10.1 FOR INTERIOR SIGNAGE SCHEDULE & NOTES.
REF
REF
ICEREF
CO
PIE
R
TV TV
CO
PIE
R
CO
PIE
R
COPIER
160
STAIRS125
STAIRS
101
WAITING
105
MEETINGROOM
104
FOYER
106
WOMEN107
MEN
156
TRAININGROOM
155
FOYER
159
MEN158
WOMEN
126
SHOWERROOM
122
JAN.
123
MEN124
WOMEN
121
CORRIDOR
161
COMM.ROOM
140
ELEC.
114
DOHIT
144
BREAKROOM
118
BREAKROOM
157
JAN.
171
STOR.
112
OFFICE
113
OFFICE
132
OFFICE133
OFFICE136
OFFICE137
OFFICE127
OFFICE
128
OFFICE
130
OFFICE131
OFFICE134
OFFICE135
OFFICE138
OFFICE139
OFFICE170
OFFICE168
OFFICE166
OFFICE164
OFFICE
163
OFFICE
148
OFFICE149
OFFICE
154
MECHANICALROOM
151
OFFICE
152
OFFICE150
OFFICE147
OFFICE
143
CORRIDOR
146
CORR.
165
CORRIDOR
162
CORR
.
145
CORR
IDOR
153
CORR
IDOR
141
CORR
IDOR
129
CORR.
116
CORR
IDOR103
INTAKE
142
CORRIDOR
155
EXIT
160
ST
159
BB7
158
BB7
157
BB2
156
CNF
161
BB2
163
BB2A
156
EXIT
171
BB2
170
BB2A
168
BB2A
166
BB2A
167
BB2
164
BB2A
144
BB2
147
BB2A
150
BB2A
152
BB2A
151
BB2A
149
BB2A
148
BB2A
154
BB2
106
BB7
107
BB7
109A
BB2
113
BB2A
112
BB2A
118
BB2
117
BB2
119
BB2
120
BB2
124
BB7
122
BB2
123
BB7
125
ST
126
BB7
127
BB2A
128
BB2A
130
BB2A
131
BB2A
132
BB2A
133
BB2A
137
BB2A
136
BB2A
134
BB2A
135
BB2A
139
BB2A
138
BB2A
140
BB2
105
BB2
114
BB2
111
BB2
121
EXIT
160
EXIT
104
EXIT
SEE GENERAL
NOTE E ON
SHEET A10.1
9"
1 3 5 7
642
15 13 11
14 12
19 17
20 18 16
9
8 10
CO
PIE
R
167
OFFICE169
OFFICE
169
BB2
EMB
156
OCP
156
EXIT
NOTE:
CENTER
ON WALL
9"
109
BB2
110
BB2
110
DOH
117
PLANROOM
108
CORRIDOR
109
SCANNING111
OFFICE
119
STOR.
120
STOR.
109A
COPYROOM
115
CORRIDOR
117
BB2
102
INTAKE
156
CNF
115
EXIT
141
EXIT
143
EXIT
153
EXIT
162
EXIT
9"
9"
9"
9"
268
ST
338
ST
2ND FL LANDING
3RD FL LANDING
227
ST
320
ST
2ND FL LANDING
3RD FL LANDING
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A1.4
1ST
FLOO
R SI
GNAG
E PL
AN
SAB
SCALE: 1/8" = 1'
0 8' 16'4'
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A4.1
INTE
RIOR
PAR
TITI
ON N
OTES
& D
ETAI
LS
SAB
A. UNLESS OTHERWISE NOTED, TYPICAL NEW INTERIOR NON-LOAD BEARING
INTERIOR METAL STUD PARTITIONS TO BE 3-5/8" 25 GAUGE METAL STUDS AT
16" O.C. WITH 5/8" TYPE X GYPSUM WALLBOARD. REFER TO FINISH SCHEDULE
FOR THOSE LOCATIONS INDICATED TO RECEIVE EITHER MOLD &
MOISTURE-RESISTANT GYPSUM WALLBOARD OR TILE BACKING PANELS IN
LIEU OF GYPSUM WALLBOARD.
B. WHERE NEW INTERIOR PARTITIONS HAVE TO ALIGN WITH EXISTING INTERIOR
PARTITIONS, MATCH DEPTH OF EXISTING METAL STUDS AND THICKNESS OF
GYPSUM WALLBOARD (E.G. 5/8", 1/2") AS REQUIRED.
C. ON THE 1ST AND 2ND FLOORS, ALL NEW NON-RATED NON-LOAD BEARING
METAL STUD PARTITIONS SHALL EXTEND FROM FINISH FLOOR TO THE
UNDERSIDE OF THE EXPOSED CEILING SUSPENSION SYSTEM OR GYPSUM
WALLBOARD SOFFIT/CEILING ABOVE. SEE DETAIL 3/A4.1 FOR TYPICAL WALL
SECTION AT EXPOSED CEILING SUSPENSION SYSTEM.
D. ON THE 3RD FLOOR, ALL NEW NON-RATED NON-BEARING INTERIOR METAL
STUD PARTITIONS SHALL TERMINATE AT 6" ABOVE FINISH CEILING. SEE
DETAIL 1/A4.1 FOR TYPICAL WALL SECTION. DETAIL 2/A4.1 MAY BE
SUBSTITUTED FOR DETAIL 1/A4.1 WHERE DESIRED. (NOT APPLICABLE.)
E. AT SMOKE PARTITIONS, NON-LOAD BEARING INTERIOR METAL STUD
PARTITIONS SHALL EXTEND FULL-HEIGHT TO THE UNDERSIDE OF THE FLOOR
OR ROOF DECK ABOVE. SEE DETAIL 4/A4.1 FOR TYPICAL SMOKE PARTITION.
ACOUSTICAL SEALANT USED IN SMOKE PARTITIONS SHALL BE TESTED FOR
SMOKE SEALING AND SHALL MEET CLASS A FINISH REQUIREMENTS WHEN
TESTED IN ACCORDANCE WITH ASTM E84 (UL723).
F. PROVIDE 20-GAUGE METAL STUDS WHERE STUDS WILL BE SUPPORTING
WALL-MOUNTED CABINETS.
G. PROVIDE 16-GAUGE METAL STUDS WHERE STUDS WILL BE SUPPORTING
WALL-MOUNTED DRINKING FOUNTAINS, WATER COOLERS OR GRAB BARS.
H. PROVIDE GLASS FIBER SOUND ATTENUATION BATTS IN ALL NEW PARTITIONS
ENCLOSING THE FOLLOWING TYPES OF ROOMS: BREAK ROOMS (WITH
DOORS), CONFERENCE/MEETING ROOMS, OFFICES, TOILET ROOMS, AND
WORK ROOMS (WITH DOORS). PROVIDE 3-1/2" THICK BATTS AT 3-5/8" METAL
STUDS AND 6" BATTS AT 6" METAL STUDS. PLACE SOUND ATTENUATION
BATTS IN CAVITIES FORMED BY FRAMING MEMBERS TO PRODUCE A FRICTION
FIT BETWEEN EDGES OF INSULATION AND ADJOINING FRAMING MEMBERS.
WHERE PARTITION WALL CAVITY HEIGHTS EXCEED 96 INCHES, SUPPORT
UNFACED BATTS MECHANICALLY TO AVOID SLIPPING DOWNWARD.
SUPPORTS USED TO HOLD BATTS IN PLACE SHALL BE NON-COMBUSTIBLE.
I. GYPSUM WALLBOARD CONTROL JOINTS SHALL BE PROVIDED WHERE A
PARTITION RUNS IN AN UNINTERRUPTED STRAIGHT PLANE EXCEEDING 30
LINEAR FEET. COORDINATE LOCATIONS WITH ARCHITECT PRIOR TO
INSTALLATION. SEE DETAIL 5/A4.1 FOR TYPICAL CONTROL JOINT AT
NON-RATED PARTITIONS. SEE DETAIL 6/A4.1 FOR OPTIONAL CONTROL JOINT
LOCATIONS AT DOOR FRAMES.
J. SEE DETAIL 7/A4.1 FOR TYPICAL CORNER INTERIOR NON-LOAD BEARING
GYPSUM WALLBOARD METAL STUD PARTITION INTERSECTION.
K. TO REDUCE SOUND TRANSMISSION THROUGH PARTITIONS, DO NOT PLACE
ELECTRICAL DEVICES BACK-TO-BACK. ALL DEVICES SHALL BE OFFSET 24"
MINIMUM WHERE POSSIBLE. WHERE 24" IS NOT POSSIBLE, ELECTRICAL
DEVICES SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF NO LESS
THAN THE DEPTH OF THE PARTITION CAVITY WHERE THE CAVITY IS FILLED
WITH SOUND ATTENUATION BATTS.
INTERIOR PARTITION NOTES
SCALE:
GWB PARTITION1
A4.1 A4.1
3" = 1'-0" 092900-01
SOUND ATTENUATION
BATTS WHERE REQUIRED
METAL STUDS AT 16" O.C.
MAX. - SIZE & GAUGE
DETERMINED BY PARTITION
TYPE
FINISH CEILING AS
SCHEDULED
6"
ROOF OR FLOOR DECK
METAL STUD BRACING
AT 45° AND 8'-0" O.C.
MAX., ALTERNATE
DIRECTION IF POSSIBLE
TOP OF STRUCTURAL SLAB
CONT. METAL TRACK -
ATTACH WITH FASTENERS AT
24" O.C. AND 6" FROM ENDS
BASE AS SCHEDULED
CONT. ACOUSTICAL SEALANT
(BOTH SIDES)
FLOOR FINISH AS SCHEDULED
DEEP LEG TRACK
10' M
AX
.
5/8" GYPSUM WALLBOARD
BOTH SIDES
SCALE:
GWB PARTITION2
A4.1 A4.1
3" = 1'-0" 092900-02
5/8" GYPSUM WALLBOARD
BOTH SIDES
METAL STUDS AT 16" O.C.
MAX. - SIZE & GAUGE
DETERMINED BY WALL
TYPE
FINISH CEILING AS
SCHEDULED
6"
EXTEND STUDS TO
STRUCTURE ABOVE
ROOF OR FLOOR DECK
CONT. METAL SLIP TRACK -
ATTACH W/ FASTENERS AT
24" O.C. AND 6" FROM ENDS
TOP OF STRUCTURAL SLAB
CONT. METAL TRACK -
ATTACH WITH FASTENERS AT
24" O.C. AND 6" FROM ENDS
BASE AS SCHEDULED
CONT. ACOUSTICAL SEALANT
(BOTH SIDES)
FLOOR FINISH AS SCHEDULED
SOUND ATTENUATION
BATTS WHERE REQUIRED
SCALE:
CONTROL JOINT - GWB5
A4.1 A4.1
6" = 1'-0" 092900-05
1/2" MAX.
GYPSUM WALLBOARD,
TYPICAL
VINYL OR ZINC CONTROL
JOINT
SOUND INSULATION
COMPRESSED TO FILL
OPENING
METAL STUD, TYPICAL
JOINT COMPOUND,
TYPICAL
SOUND INSULATION
WHERE SCHEDULED
30'-0" MAX.30'-0" MAX.
SCALE:
GWB SMOKE PARTITION4
A4.1 A4.1
3" = 1'-0" 092900-04
SOUND ATTENUATION
BATTS WHERE REQUIRED
METAL STUDS AT 16" O.C.
MAX. - SIZE & GAUGE
DETERMINED BY PARTITION
TYPE
TOP OF STRUCTURAL SLAB
CONT. METAL TRACK -
ATTACH WITH FASTENERS AT
24" O.C. AND 6" FROM ENDS
BASE AS SCHEDULED
FINISH CEILING AS
SCHEDULED
CONT. FLEX OR SLOTTED
METAL DEFLECTION TRACK
- ATTACH WITH FASTENERS
AT 24" O.C. MAX. AND 6"
FROM ENDS
CONT. ACOUSTICAL SEALANT
FLOOR OR ROOF DECK
NOTE: HOLD GWB DOWN
3/8" FROM DECK (1/2" MAX.)
CONT. ACOUSTICAL SEALANT
(BOTH SIDES)
FLOOR FINISH AS SCHEDULED
5/8" GYPSUM WALLBOARD
BOTH SIDES
SCALE:
GWB CONTROL JOINTS AT DOOR6
A4.1 A4.1
1" = 1'-0" 092900-06
DOOR FRAME
CONTROL JOINT, TYPICAL
- EXTEND FULL HEIGHT TO
TOP OF PARTITION
SCALE:
CORNER - GWB PARTITION7
A4.1 A4.1
3" = 1'-0" 092900-07
CORNER BEAD, TYPICAL
GYPSUM WALLBOARD
- THICKNESS AND NUMBER
OF LAYERS DETERMINED BY
PARTITION TYPE
METAL STUD - LOCATE AT
ABUTTING PARTITION AND
ATTACH THRU GYPSUM
WALLBOARD TO STUD IN
ABUTTING PARTITION
TAPE AND JOINT COMPOUND
SCALE:
GWB PARTITION3
A4.1 A4.1
3" = 1'-0" 092900-03
SOUND ATTENUATION
BATTS WHERE REQUIRED
METAL STUDS AT 16" O.C.
MAX. - SIZE & GAUGE
DETERMINED BY PARTITION
TYPE
ACOUSTICAL PANEL
CEILING
TOP OF STRUCTURAL SLAB
CONT. METAL TRACK -
ATTACH WITH FASTENERS AT
24" O.C. AND 6" FROM ENDS
BASE AS SCHEDULED
CONT. ACOUSTICAL SEALANT
(BOTH SIDES)
FLOOR FINISH AS SCHEDULED
12 GAUGE SPLAY WIRES
INSTALLED AT MAX. 45° FROM
HORIZ. AXIS IN OPPOSITE
DIRECTIONS AND
PERPENDICULAR TO PARTITION
CONT. METAL TRACK - ATTACH
WITH FASTENERS TO CEILING
SUSPENSION SYSTEM GRID
COMPRESSIBLE GASKET
5/8" GYPSUM WALLBOARD
BOTH SIDES
3'-0" X 4'-0" ACOUSTICAL
WALL PANEL, TYPICAL
SCALE:
INTAKE 1021
A6.3
1/4" = 1'-0"
2'-6"
4'-0"
7'-4"
2'-8"
PLASTIC LAMINATE-FACED
PARTITION, TYPICAL
TEMPERED GLASS HEADER
PANEL WITH 4" HIGH VINYL
COPY*, TYPICAL
TEMPERED GLASS DIVIDER
PANEL, TYPICAL
NEW SUSPENDED LINEAR
DIRECT/INDIRECT FLUORESCENT
LIGHT FIXTURE, TYPICAL
FILE FILE FILE FILE FILE
PLASTIC LAMINATE FACED
BASE CABINET, TYPICAL
SCALE:
INTAKE 1022
A6.3
1/4" = 1'-0"
SCALE:
INTAKE 1025
A6.3
1/4" = 1'-0"
1'-6" 1"
8"
SCALE:
INTAKE 1023
A6.3
1/4" = 1'-0"
SCALE:
INTAKE 1026
A6.3
1/4" = 1'-0"
FILE FILE
2'-6"
SCALE:
INTAKE 1027
A6.3
1/4" = 1'-0"
5 EQUAL WORKSTATIONS2'-0"
1'-6"
2'-0"
1'-0" 2'-0"
7'-6"
KNEE
SPACE
KNEE
SPACE
KNEE
SPACE
KNEE
SPACE
KNEE
SPACE
KNEE
SPACE
KNEE
SPACE
OPENOPENOPENOPENOPEN
2'-6"
3'-0"
3"
4
A12.3
5
A12.3
PRE-FAB PENCIL
DRAWER, TYPICAL AT
EACH WORKSTATION
- COORDINATE
LOCATIONS WITH
OWNER
PLASTIC LAMINATE-FACED
COUNTERTOP WITH MODESTY
PANEL BELOW, TYPICAL
STATION 1 STATION 3 STATION 5 STATION 7 STATION 9 STATION 1STATION 3STATION 5STATION 7STATION 9
OPEN TO
CORRIDOR
141
SCALE:
INTAKE 1024
A6.3
1/4" = 1'-0"
EXISTING PENDANT-MOUNT LINEAR
FLUORESCENT LIGHT , TYPICAL
FILE FILE
PLASTIC LAMINATE-FACED LIGHT
BRIDGE, TYPICAL
KNEE
SPACE
KNEE
SPACE
1
A12.3
3'-0"
4'-0"
3'-4"
3"4'-6"
4'-6"5'-0"
3"
TEMPERED GLASS DIVIDER
PANELS, TYPICAL
OPEN
OPEN OPEN
2'-10"
PLASTIC LAMINATE-FACED
COUNTERTOP ON PARTIAL HEIGHT
METAL STUD GWB PARTITION
3'-0" 3'-0"8 EQUAL BORROWED LITES
ALIGN BORROWED LITE
WITH 3'-0" CLEAR OPENING
BELOW, TYPICAL BOTH
ENDS OF PARTITION
7'-9"
±12'-0"
10
A12.1
12
A12.1
11
A12.1
9
A12.1
9
A12.1
OPP.
3'-10"
6'-8"
6'-8"
*NOTE: CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR UP A COMBINATION OF UP TO 10 LETTERS
AND NUMBERS PER STATION (21 STATIONS TOTAL).
1'-0" TYP. 1'-0" TYP.
BUTT JOINT, TYPICAL
OPENOPENOPENOPENOPEN
1'-0"
6'-8"
4'-0"
3'-4"
7'-4"
4'-0"
4'-0"
3" 3"
OPEN TO
WAITING
101
2
A12.3
3
A12.3
NOTE: THE THICKNESS OF ALL
MONOLITHIC TEMPERED GLASS
PANELS IS TO BE DETERMINED
BY THE FABRICATOR FOR BOTH
THE APPLICATION AND SIZE OF
THE PANELS, BUT SHALL BE NO
LESS THAN 1/4".
1/4" CLEAR TEMPERED
GLASS, TYPICAL THIS
ELEVATION
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A6.3
INTE
RIOR
ELE
VATI
ONS
- 1ST
FLO
OR
SAB
SCALE: 1/4" = 1'
0 2' 4' 8'
SCALE:
INTAKE 103 & CORRIDOR 1451
A6.4
1/4" = 1'-0"
145
CORRIDOR OPENOPENOPEN
FILE
KNEE
SPACE
FILE
KNEE
SPACE
KNEE
SPACE
OPEN TO
WAITING
101
SCALE:
INTAKE 10310
A6.4
1/4" = 1'-0"
1'-0" 2'-0" 1'-6"3'-0"
7'-6"
2'-6"
MANUAL CASH DRAWER
WITH UNDER COUNTER
MOUNTS (N.I.C.)
PLASTIC LAMINATE-FACED
COUNTERTOP - PROVIDE METAL
BRACKET SUPPORTS AS
REQUIRED TO SUPPORT
COUNTERTOP
SAFE (N.I.C.)
3"
STATION 11STATION 13STATION 15
SCALE:
INTAKE 103 & CORRIDOR 1453
A6.4
1/4" = 1'-0"
145
CORRIDOR
SCALE:
INTAKE 103 & CORRIDOR 1452
A6.4
1/4" = 1'-0"
145
CORRIDOROPEN OPEN
9'-0"
7'-4"
1'-8"
SCALE:
INTAKE 103 & CORRIDOR 1454
A6.4
1/4" = 1'-0"
145
CORRIDOROPEN OPEN
STATION 12 STATION 14
OPEN
FILE FILE FILE
SCALE:
INTAKE 103 & CORRIDOR 1455
A6.4
1/4" = 1'-0"
145
CORRIDOR OPENOPEN
FILEFILE
KNEE
SPACE
FILE
3"9"
3'-2"
5"
1'-9"
4'-0"
2'-8"
8"
7'-4"
1'-0"
1'-6" 1"2'-0"
2'-6"
KNEE
SPACE
KNEE
SPACE
KNEE
SPACE
KNEE
SPACE
KNEE
SPACE
2'-6"
145
CORRIDOROPEN OPEN
FILE FILE
KNEE
SPACE
FILE
KNEE
SPACE
KNEE
SPACE
STATION 17 STATION 19
PLASTIC LAMINATE FACED CABINET
- SEE INTERIOR ELEVATION 2/A6.5
SCALE:
INTAKE 1037
A6.4
1/4" = 1'-0"
OPENOPEN
STATION 17STATION 19
SCALE:
INTAKE 103 & CORRIDOR 1456
A6.4
1/4" = 1'-0"
3/4" REVEAL, TYPICAL
SCALE:
INTAKE 1038
A6.4
1/4" = 1'-0"
OPENOPEN
STATION 18STATION 16
OPEN
STATION 20
SCALE:
INTAKE 1039
A6.4
1/4" = 1'-0"
OPEN OPENOPEN
STATION 18 STATION 16STATION 20
FILE
KNEE
SPACE
FILE
KNEE
SPACE
FILE
KNEE
SPACE
4'-0"
OPEN TO
WAITING
101
2'-6" 2'-6"
1'-0"
1'-0"
1'-0"
4'-0"
OPEN TO
CORR.
143
4
A12.3
5
A12.3
3
A12.3
SIM.
STATION 14 STATION 12
STATION 13STATION 11 STATION 15
CASHIER
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A6.4
INTE
RIOR
ELE
VATI
ONS
- 1ST
FLO
OR
SAB
SCALE: 1/4" = 1'
0 2' 4' 8'
SCALE:
PUBLIC FOYER 100, WAITING 101, & FOYER 1043
A6.5
1/4" = 1'-0"
EXISTING AED CABINET
(RELOCATED)
SCALE:
WAITING 101 & FOYER 1044
A6.5
1/4" = 1'-0"
SCALE:
CORRIDOR 1452
A6.5
1/4" = 1'-0"
OPEN TO
CORR.
145
SCALE:
INTAKE 1031
A6.5
1/4" = 1'-0"
1'-0"2'-0"
OPEN TO
CORR.
145
2'-6"
GYPSUM WALLBOARD
END WALL WITH
HEADER SPANNING
CORRIDOR, TYPICAL
PLAN STORAGE: PLASTIC LAMINATE-FACED
CABINET WITH (77) 8" X 8" FIXED CUBBIES
AND (35) 11" X 11-1/2" CUBBIES WITH
ADJUSTABLE SHELVES
OPEN TO INTAKE 103
6'-10"
3"
SCALE:
WAITING 101 & FOYER 1046
A6.5
1/4" = 1'-0"
104
FOYER
ALUMINUM-FRAMED
STOREFRONT WITH CLEAR
TEMPERED GLASS, TYPICAL
OPEN TO
WAITING
101
101
WAITING
SCALE:
FOYER 1047
A6.5
1/4" = 1'-0" SCALE:
FOYER 104 & WAITING 1018
A6.5
1/4" = 1'-0"
PANEL SIGN
- SEE SIGNAGE
PLAN & SCHEDULE
OPEN TO
WAITING
101
A
B
C
OPEN TO CORRIDOR 145
3"
SCALE:
WAITING 101 - SECURITY DESK5
A6.5
1/4" = 1'-0"
OPEN
TO
FOYER
104
ELEV
OPEN TO
CORRIDOR
108
PLASTIC LAMINATE-FACED
DESK AND COUNTERTOP
2'-6"
TABLE
(N.I.C.)
PLASTIC LAMINATE
FACED FORM STORAGE
CABINET
6'-0 1/2"
3'-0 1/4" 3'-0 1/4"
OPEN TO
INTAKE
103
OPEN TO
CORR.
143
5'-0"
104
FOYER104
FOYER
101
WAITING
NEW PLASTIC LAMINATE-FACED
COUNTERTOP (20" DEEP)
2
A12.4
2'-6"
1'-10"
4'-4"
8'-1" 6'-11"
1 3/8" 1 3/8"
5'-6 3/4"
PLASTIC LAMINATE-FACED COUNTERTOP
WITH 4" HIGH BACKSPLASH
15'-2 3/4" (F.V.)
5'-1"1'-4"1'-4"
1'-8"
3'-2"
104
FOYER TABLE
(N.I.C.)
1'-4"1'-4"
3'-2"
4"
SECURITY
DESK
OPEN
TO
FOYER
104
CASHIER
ALIG
N
TV
5'-5"
RUBBER
STAIR
NOSING
EXIST. LOW POWER
DOOR OPERATOR
CONTROL
2'-6"
MIN. CLR.
6"
TV
16-20 11-15
1-10
6'-10"
2'-6"
2'-6"
50" MONITOR FOR QUEUING
SYSTEM (BY OWNER)
50" MONITOR FOR QUEUING
SYSTEM (BY OWNER)
43" MONITOR FOR QUEUING
SYSTEM (BY OWNER)
6'-0"
6'-5"
ACCENT PAINT
3
A12.4
ACCENT PAINT
ACCENT PAINT
6" HIGH, 1/4" FLAT CUT ALUMINUM
NUMBERS WITH CLEAR ANODIZED
FINISH, TYPICAL
4" HIGH WHITE VINYL
LETTERS
TEMPERED GLASS DIVIDER
PANEL, TYPICAL
BUTT JOINT, TYPICAL
3'-6" 1'-3"1'-3"EQ.EQ.
1'-0"
2'-6"
3'-4"
4'-0"
3'-4"
4'-0"
PASS-THRU OPENING
3"
2'-10"3'-4"2'-10" 3'-4"
6'-10"
4'-0"
1'-0" TYP.
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A6.5
INTE
RIOR
ELE
VATI
ONS
- 1ST
FLO
OR
SAB
SCALE: 1/4" = 1'
0 2' 4' 8'
SCALE:
BREAK ROOM 1189
A6.6
1/4" = 1'-0"
2'-10"
7'-3 13/16"1"
1" 7'-3 13/16" 3'-4" 1"
10'-9 13/16" (FV)
REFRIGERATOR
(N.I.C.), TYPICAL
1'-8"
2'-6"
7'-0"
SCALE:
CORRIDOR 14510
A6.6
1/4" = 1'-0"
1"3'-0" 1'-6"
4'-7"
3'-0" 1'-6" 1"
2'-10"
1'-8"
2'-6"
7'-0"
4'-7"
70" TELEVISION MONITOR
(N.I.C.) WITH WALL MOUNT
BRACKET (N.I.C.), TYPICAL
SCALE:
TRAINING ROOM 15511
A6.6
1/4" = 1'-0"
EQ. EQ.
1X6 WOOD CHAIR RAIL WITH
PAINT FINISH
2'-9"
MARKER BOARD
(N.I.C.)
MARKER BOARD
(N.I.C.)
5'-4"
7'-0"
SCALE:
HEALTH DEPARTMENT 1106
A6.6
1/4" = 1'-0"
5'-0"
CLEAR MIN.
PLASTIC LAMINATE -FACED
MODESTY PANEL, TYPICAL
PLASTIC LAMINATE-FACED
COUNTERTOP, TYPICAL
PLASTIC LAMINATE-FACED
DIVIDER, TYPICAL
SCALE:
HEALTH DEPARTMENT 1103
A6.6
1/4" = 1'-0" SCALE:
HEALTH DEPARTMENT 1104
A6.6
1/4" = 1'-0"
FILE
2'-6"
SCALE:
HEALTH DEPARTMENT 1105
A6.6
1/4" = 1'-0"
PLASTIC
LAMINATE-FACED BASE
CABINET, TYPICAL
KNEE
SPACE
KNEE
SPACE
KNEE
SPACE
2'-0"
5'-6"
2'-6"
3"
REFRIGERATOR VALVE
BOX - SEE PLUMBING
DRAWINGS
1
A12.2
2
A12.2
3
A12.2
1
A12.2
FILE
PRE-FAB PENCIL DRAWER,
TYPICAL - COORDINATE
LOCATIONS WITH OWNER
1'-3" 1"
5"
EQ. EQ.
1'-6"
4'-0"
1'-0"6" 2'-0" 1'-3" 1"
KNEE
SPACE
1
A12.4
SCALE:
PLAN ROOM 1177
A6.6
1/4" = 1'-0" SCALE:
PLAN ROOM 1178
A6.6
1/4" = 1'-0"
10
A12.1
OPEN
12
A12.1
11
A12.1
9
A12.1
9
A12.1
OPP.
OPEN OPEN
2'-10"
6'-8"
6'-8"
20" DEEP PLASTIC
LAMINATE-FACED COUNTERTOP
ON PARTIAL HEIGHT METAL STUD
GWB PARTITION
SCALE:
COPY 109A / SCANNING 1092
A6.6
1/4" = 1'-0"
3'-0" 1"3'-0"
6'-1"
2'-10"
1'-8"
2'-6"
7'-0"
3'-0"3'-0"8 EQUAL BORROWED LITES
ALIGN BORROWED LITE
WITH 3'-0" CLEAR OPENING
BELOW, TYPICAL BOTH
ENDS OF PARTITION
HOLLOW METAL
BORROWED LITE
1
A12.2
5
A12.3
4
A12.3
3'-5"
3'-4"1"
2'-8"
6'-1"
WALL BASE AS SCHEDULED
24'-0"
9 EQUAL
5 EQUAL
5 EQUAL
2'-0"
PLASTIC LAMINATE-FACED
DIVIDER, TYPICAL
SCALE:
SCANNING 1091
A6.6
1/4" = 1'-0"
KNEE
SPACE
KNEE
SPACE
KNEE
SPACE
4'-0" 4'-0" 4'-0" 4'-0" 1"
16'-1"
PLASTIC LAMINATE-FACED WALL
CABINETS WITH ADJUSTABLE SHELVING
PLASTIC LAMINATE-FACED
COUNTERTOP, BACKSPLASH
AND CABINETS, TYPICAL
EXISTING BORROWED
LITE, TYPICAL
NEW DOOR AS SCHEDULED
1"
8 EQUAL COMPARTMENTS
1'-3"
3'-5"
NEW PARTIAL-HEIGHT WALL
16'-0"
NOTE: PROVIDE THREE GROMMETS IN
COUNTERTOP. SEE SHEET A1.1 FOR
LOCATIONS
1 1/2" THICK PLASTIC
LAMINATE-FACED SUPPORT
PANEL, TYPICAL
1'-8"
1
A12.2
3'-0"3'-0"
6'-1"
1" 3'-0"
2'-6"
7'-0"
3'-0"
6'-1"
3'-0" 1"3'-0"
2'-0"
3'-6"
5'-6"
PLASTIC LAMINATE-FACED
STORAGE CABINET
7'-9"
±12'-0"
6
A12.3
7
A12.3
5'-6"
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A6.6
INTE
RIOR
ELE
VATI
ONS
- 1ST
FLO
OR
SAB
SCALE: 1/4" = 1'
0 2' 4' 8'
100 FROM WAITING 101EXTERIOR
SILL
- -- --- -- -- --
EXISTING ALUMINUM ENTRANCE DOORS & FRAMING- --11
101
FROM CORRIDOR 142WAITING 101 ---
102 NUMBER NOT USED
103 NUMBER NOT USED
FROM FOYER 104EXTERIOR - -
ALUM
- --- -- -- --
MEN 107
EXISTING ALUMINUM ENTRANCE DOORS & FRAMING WITH ACCESS CONTROL- --20104
FROM MEETING ROOM 105FOYER 104105 (2) 3'-0" X 6'-8" 1 3/4" RHRA FG ALUM - GL-1
12
-
-
- --
-
FROM WOMEN 106FOYER 104
-
106
107 FROM -FOYER 104
- -- --- -- -- --
EXISTING WOOD DOOR & H.M. FRAME - --
-- -- ----- --
12
ACCESS CONTROL
EXISTING WOOD DOOR & H.M. FRAME
108 FROM CORRIDOR 115CORRIDOR 108
109
109A
111A
TO SCANNING 109CORRIDOR 108
CORRIDOR 108 TO
FROMCORRIDOR 115
DOH 110
OFFICE 111
3'-0" X 6'-8" RH1 3/4" FG WOOD STAIN GL-1 F1HM P
3'-0" X 6'-8" RHR1 3/4" FG WOOD STAIN GL-1 F1HM P
112
113
TO
TO
OFFICE 112OFFICE 111
OFFICE 111 OFFICE 113
3'-0" X 6'-8"
3'-0" X 6'-8"
1 3/4"
1 3/4"
WOOD STAIN GL-1
WOOD STAIN GL-1
FG
FG
RH
LH
HM P
HM P
F1
F1
114 OFFICE 111 TO DOH IT 114 LH ---
115
CORRIDOR 116 TO PLAN ROOM 117 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1117
NUMBER NOT USED
118 NUMBER NOT USED
119
120
3'-0" X 6'-8" 1 3/4" WOOD STAIN -FRH HM P F1
3'-0" X 6'-8" 1 3/4" WOOD STAIN -FLH HM P F1
CORRIDOR 116 TO STORAGE 119
CORRIDOR 116 TO STORAGE 120
121 FROM CORRIDOR 121EXTERIOR - -- --- -- -- --
EXISTING ALUMINUM ENTRANCE DOOR & FRAMING WITH ACCESS CONTROL - --
122 CORRIDOR 116 FROM JANITOR 122
123 CORRIDOR 116 FROM MEN 123
124 CORRIDOR 116 FROM WOMEN 124
125 CORRIDOR 116 TO STAIRS 125
125A EXTERIOR FROM STAIRS 125
- -- --- -- -- --- --
- -- --- -- -- --- --
- -- --- -- -- --- --
- -- --- -- -- 1 HR-- --
- -- --- -- -- 1 HR-- --
EXISTING WOOD DOOR & H.M. FRAME
EXISTING WOOD DOOR & H.M. FRAME
EXISTING WOOD DOOR & H.M. FRAME
EXISTING WOOD DOOR & H.M. FRAME WITH ACCESS CONTROL
EXISTING H.M. DOOR & FRAME
126 CORRIDOR 116 TO SHOWER ROOM 126 - -- --- -- -- --- --
12 EXISTING WOOD DOOR & H.M. FRAME
127
128
129
130
NUMBER NOT USED
CORRIDOR 116
CORRIDOR 116
TO
TO
OFFICE 127
OFFICE 128
OFFICE 130TOCORRIDOR 129
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1
131 OFFICE 131TOCORRIDOR 129 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
132 OFFICE 132TOCORRIDOR 129 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
OFFICE 133TOCORRIDOR 129 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1133
OFFICE 134TOCORRIDOR 129 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1134
135 OFFICE 135TOCORRIDOR 129 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
136 OFFICE 136TOCORRIDOR 129 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
OFFICE 137TOCORRIDOR 129 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1
OFFICE 138TOCORRIDOR 129 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1
137
138
139 OFFICE 139TOCORRIDOR 129 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
140 ELECTRICAL 141TOCORRIDOR 129 - -- --- -- -- 1 HR-- --
12 EXISTING H.M. DOORS & FRAME
141 NUMBER NOT USED
142
NUMBER NOT USED
143
144
145
146
147
FROMFOYER 104 --- PANIC EXIT DEVICE, ACCESS CONTROLCORRIDOR 143
CORRIDOR 143 BREAK ROOM 144TO - -- --- -- -- --- --
12 EXISTING WOOD DOOR & H.M. FRAME
NUMBER NOT USED
NUMBER NOT USED
CORRIDOR 146 TO OFFICE 147 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
MA
RK
DOOR
TO
/F
RO
M
HA
ND
TH
IC
KN
ES
S
TY
PE
MA
TE
RIA
L
FIN
IS
H
GLA
SS
LABEL
MA
TE
RIA
L
FIN
IS
H
TY
PE
HE
AD
JA
MB
RO
OM
RO
OM
HDWSTC
HA
RD
WA
RE
SE
T N
O.
OP
EN
IN
G
SIZ
E
DOOR & FRAME SCHEDULE
REMARKSFRAME
FIR
E R
AT
IN
G/
SM
OK
E
ST
C R
AT
IN
G
1S
T F
LO
OR
BHA BOTH HANDS ACTIVE
BHRA BOTH HANDS REVERSE ACTIVE
LH LEFT HAND
LHA LEFT HAND ACTIVE
LHR LEFT HAND REVERSE
LHRA LEFT HAND REVERSE ACTIVE
RH RIGHT HAND
RHA RIGHT HAND ACTIVE
RHR RIGHT HAND REVERSE
RHRA RIGHT HAND REVERSE ACTIVE
A. ALL DOORS AND FINISH HARDWARE SHALL BE COMPLIANT WITH THE REQUIREMENTS OF SECTIONS 404.2.7
THROUGH 404.2.11 OF THE 2012 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION (FACBC).
B. REFER TO SPECIFICATION SECTION 08 80 00 GLAZING FOR DESCRIPTION OF GLASS TYPE GL-1.
C. AT ALL DOOR FRAMES, CONTINUOUSLY SEAL BETWEEN THE DOOR FRAME AND THE ADJACENT WALL AND
FLOOR SURFACES.
D. ALL FIRE/SMOKE RATED DOORS TO BE SELF-CLOSING AND SELF-LATCHING.
E. ALL EXIT DOOR HARDWARE (INCLUDING ACCESS-CONTROLLED) TO BE READILY OPERABLE FROM THE
EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT IN ACCORDANCE WITH FBC
1008.1.9. FOR PANIC AND FIRE EXIT DEVICES, DEPRESSING TOUCHBAR RETRACTS LATCHBOLT. FOR MORTISE
LOCKSETS, TURNING INSIDE LEVER RETRACTS LATCHBOLT.
F1FGF
DOOR TYPES
2"VARIES2"
2"
VA
RIE
S
FRAME TYPES DOOR GENERAL NOTESDOOR HAND
10"
N432
4"
2'-8"
3'-6"
F2
2"2"
2"
6'-8"
NOM. DOOR
WIDTH - 1"
POCKET DOOR
FRAME
VERIFY
W/ MNFR.
F3
(NOT USED)
3'-10"
5'-0"
2"
4'-8"
2"
2"
3'-6"
2"
3'-4"
BORROWED
LIGHT
--
--
--
--
--
--
--
--
--
- -- --- -- -- --- --
- -- --- -- -- --- --
-
- -- --- -- -- --- --
-
- -- --- -- -- --- --
-
- -- --- -- -- --- --
-
- -- --- -- -- --- --
-
- -- --- -- -- --- --
-
- -- --- -- -- --- --
-
- -- --- -- -- --- --
-
1/A8.4
1/A8.4
1/A8.4
1/A8.4
2/A8.4
2/A8.4
2/A8.4
2/A8.4
-
-
-
-
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
01
04
3'-0" X 6'-8" 1 3/4" F1HM P1/A8.4 2/A8.4
-WOOD STAINF
110
111 DOH 110 FROM OFFICE 111 3'-0" X 6'-8" 1 3/4"
3'-0" X 6'-8" 1 3/4"
CORRIDOR 108 TO COPY 109A EXISTING WOOD DOOR & H.M. FRAME, NEW ACCESS CONTROL
3'-0" X 6'-8" 1 3/4" LHR FG WOOD STAIN GL-1 F1HM P --1/A8.4 2/A8.4 -
ACCESS CONTROL
WOOD STAIN GL-1FGLH HM P F11/A8.4 2/A8.4
--- ACCESS CONTROL, INSTALL DOH LOGO ON GLASS
LHR WOOD STAIN GL-1FG HM P F11/A8.4 2/A8.4
--- ACCESS CONTROL
ACCESS CONTROL
111B
111C
BORROWED LITE----1/A8.4 SIM. 2/A8.4 SIM.
F3HM PGL-1- ----3'-6" X 4'-8"DOH 110 OFFICE 111-
DOH 110 TO OFFICE 111 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F11/A8.4 2/A8.4
--- ACCESS CONTROL
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRHR HM P F11/A8.4 2/A8.4
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRHR HM P F11/A8.4 2/A8.4 ACCESS CONTROL
ACCESS CONTROL
116 NUMBER NOT USED -- - -- --- -- -- --- --
-
CORRIDOR 116 TO PLAN ROOM 117 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1117A --1/A8.4 2/A8.4 -
1" RADIUS PUSH-PULL HARDWARE, DEADBOLT
04
10
04
04
04
04
06
06
04
09
09
07
07
12
12
12
12
12
12
06
06
06
06
06
06
06
06
06
06
06
06
04
03
ACCESS CONTROL108A TO INTAKE 102CORRIDOR 108 3'-0" X 6'-8" 1 3/4" RH FG WOOD STAIN GL-1 F1HM P --1/A8.4 2/A8.4 -
04
06
A8.1
DOOR
& F
RAME
SCH
EDUL
E
SAB
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
152
148
149
150
151
CORRIDOR 146
CORRIDOR 146
CORRIDOR 146
CORRIDOR 146
TO
TO
TO
TO
OFFICE 148
OFFICE 149
OFFICE 150
OFFICE 151
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1
153
154
155
156A
157
158
159
160
161
162
163
164
165
166
167
168
169
171
CORRIDOR 146 TO OFFICE 152 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
FOYER 155 FROM CORRIDOR 153 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1N432RHR HM P F1
CORRIDOR 153 FROM MECHANICAL ROOM 154 - -- --- -- -- 1 HR-
EXISTING H.M. DOORS & FRAME- --12
FROM FOYER 155EXTERIOR - -- --- -- -- --
EXISTING ALUMINUM ENTRANCE DOOR & FRAMING WITH ACCESS CONTROL- --
FOYER 155 FROM TRAINING ROOM 156 (2)3'-0" X 6'-8" 1 3/4" LHR/RHRA WOOD STAIN GL-1FG HM P F1156
TRAINING ROOM 156 TO CORRIDOR 145 3'-0" X 6'-8" 1 3/4" LH WOOD STAIN HM P F1FG GL-1
FOYER 155 FROM JANITOR 157 3'-0" X 6'-8" 1 3/4" LHR WOOD STAIN HM P F1F -
FOYER 155 FROM WOMEN 158
FOYER 155 FROM MEN 159
- -- --- -- -- --- --
12
- -- --- -- -- --- --
12
EXISTING WOOD DOOR & H.M. FRAME
EXISTING WOOD DOOR & H.M. FRAME
EXISTING WOOD DOOR & H.M. FRAME WITH ACCESS CONTROLFOYER 155 TO STAIRS 160
160A FROMEXTERIOR STAIRS 160
- -- --- -- ---- --
- -- --- -- -- 1 HR-- -- EXISTING H.M. DOOR & FRAME
FOYER 155 TO COMMUNICATIONS ROOM 161 1 HR-
REPLACE EXISTING H.M. DOOR & FRAME WITH NEW, ACCESS CONTROL
FOYER 155 FROM CORRIDOR 162 3'-0" X 6'-8" 1 3/4" LHR WOOD STAIN HM P F1N432 GL-1
NUMBER NOT USED
CORRIDOR 162
CORRIDOR 162
TO
TO
OFFICE 163
OFFICE 164
TO OFFICE 166
TO OFFICE 167
TO OFFICE 169
CORRIDOR 165
CORRIDOR 165
CORRIDOR 165
ACCESS CONTROL
ACCESS CONTROL
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1
3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGLH HM P F1
TOCORRIDOR 165 3'-0" X 6'-8" 1 3/4" WOOD STAINFGRH HM P F1
FROM STORAGE 171CORRIDOR 145 3'-0" X 6'-8" 1 3/4" WOOD STAIN -FRHR HM P F1 20 MIN.-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
--
--
--
--
DOOR & FRAME SCHEDULE - CONTINUED
1S
T F
LO
OR
MA
RK
DOOR
TO
/F
RO
M
HA
ND
TH
IC
KN
ES
S
TY
PE
MA
TE
RIA
L
FIN
IS
H
GLA
SS
LABEL
MA
TE
RIA
L
FIN
IS
H
TY
PE
HE
AD
JA
MB
SILL
RO
OM
RO
OM
HDWSTC
HA
RD
WA
RE
SE
T N
O.
OP
EN
IN
G
SIZ
E
REMARKSFRAME
FIR
E R
AT
IN
G/
SM
OK
E
ST
C R
AT
IN
G
ACCESS CONTROL
- -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4
-
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 6/A12.1
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
1/A8.4 2/A8.4 -
06
3'-0" X 6'-8" 1 3/4" RH WOOD STAIN -F HM P F1 1/A8.4 2/A8.4 7/A12.1
1 HR
OFFICE 168
170 TO OFFICE 170CORRIDOR 165 3'-0" X 6'-8" 1 3/4" WOOD STAIN GL-1FGRH HM P F1-
-1/A8.4 2/A8.4 -
GL-1
COORDINATE DOOR WIDTH WITH ARCHITECT
06
06
06
06
04
12
02
03
07
12
12
05
04
06
06
06
06
06
06
06
08
A8.2
DOOR
& F
RAME
SCH
EDUL
E - C
ONTI
NUED
SAB
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A8.4
DOOR
& F
RAME
SCH
EDUL
E - C
ONTI
NUED
SAB
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
SCALE:
INTERIOR DOOR HEAD1
A8.1, A8.2, A8.3, A8.4 A8.4
3" = 1'-0" 081113-01
1/2"1/2"
WIDTH
SCHEDULED DOOR
PARTITION AS SCHEDULED OR
NOTED
SOUND ATTENUATION BATTS
WHERE REQUIRED
CONTINUOUS SEALANT AROUND
PERIMETER OF FRAME, TYPICAL
EACH SIDE
HOLLOW METAL FRAME
METAL STUD BOX HEADER
5/8"
2"
1/2"
NOTE: AT STC-RATED PARTITIONS,
SOLIDLY PACK FRAME WITH #8
DENSITY ROCK WOOL INSULATION
1 15/16" 1 9/16"
WIDTH + 1"
SCALE:
INTERIOR DOOR JAMB2
A8.1, A8.2, A8.3, A8.4 A8.4
3" = 1'-0" 081113-02
1/2"
1/2"
5/8"
PARTITION AS SCHEDULED OR
NOTED
SOUND ATTENUATION BATTS
WHERE REQUIRED
HOLLOW METAL FRAME
CONTINUOUS SEALANT AROUND
PERIMETER OF FRAME, TYPICAL
EACH SIDE
2"
WID
TH
+
1"
WID
TH
SCHEDULED DOOR
1/2"
NOTE: AT STC RATED PARTITIONS,
SOLIDLY PACK FRAMES WITH #8
DENSITY ROCK WOOL INSULATION
AND SPOT GROUT FRAMES AT JAMB
ANCHOR CLIPS WITH MORTAR
1 15/16"
1 9/16"
A
INTERIOR ALUMINUM-FRAMED
STOREFRONT SYSTEM
3
A8.5
2
A8.5
1
A8.5
4
A8.5
12'-9 3/4"
(3 EQUAL)
9'-0"
3'-0"
3'-8"
2'-4"
3
A8.5
2
A8.5
1
A8.5
12'-9 3/4"
3
A8.5
5
A8.5
1
A8.5
B
INTERIOR ALUMINUM-FRAMED
STOREFRONT SYSTEM
C
INTERIOR ALUMINUM-FRAMED
STOREFRONT SYSTEM
13'-9"
6'-0"3'-10 1/2" 3'-10 1/2"
STOREFRONT ELEVATION TYPES
OPP.OPP.
3
A8.5
(3 EQUAL)
STOREFRONT ELEVATION TYPE NOTES:
1. FIELD-VERIFY ALL ROUGH OPENINGS AND
DIMENSIONS PRIOR TO FABRICATION.
2. ALL GLAZING TO BE CLEAR TEMPERED GLASS.
REFER TO SPECIFICATION SECTION 08 80 00
GLAZING FOR ADDITIONAL REQUIREMENTS.
105
9'-0"
3'-0"
3'-8"
2'-4"
6'-8"
4
A8.5
OPP.
4
A8.5
9'-0"
3'-0"
3'-8"
2'-4"
4
A8.5
A8.5
STOR
EFRO
NT E
LEVA
TION
TYP
ES
SAB
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
SCALE:
STOREFRONT HEAD1
A8.5 A8.5
3" = 1'-0" 084113-01
6"
ALUMINUM-FRAMED
STOREFRONT SYSTEM
CORNER BEAD
ACOUSTICAL TILE CEILING
6" 20 GAUGE METAL STUDS AT 16"
O.C., EXTEND TO DECK ABOVE
AND PROVIDE DIAGONAL BRACING
AT 48" O.C. MAX. (ALTERNATE
DIRECTION IF POSSIBLE)
5/8" GYPSUM WALLBOARD
SHIM WITH CONT. SEALANT &
BACKER ROD BOTH SIDES
2X FIRE-RETARDANT WOOD
BUCK
5/8" GYPSUM WALLBOARD ON
GRID SUSPENSION SYSTEM
GLAZING AS SPECIFIED
SCALE:
STOREFRONT SILL3
A8.5 A8.5
3" = 1'-0" 084113-03
ALUMINUM-FRAMED
STOREFRONT SYSTEM
SHIM WITH CONTINUOUS
SEALANT & BACKER ROD
BOTH SIDES
GLAZING AS SPECIFIED
SCALE:
STOREFRONT JAMB2
A8.5 A8.5
3" = 1'-0" 084113-02
ALUMINUM-FRAMED
STOREFRONT SYSTEM
SHIM WITH CONT. SEALANT &
BACKER ROD BOTH SIDES
EXISTING GYPSUM WALLBOARD ON
METAL FURRING OVER CMU
- PATCH AND REPAIR GYPSUM
WALLBOARD AS REQUIRED WHERE
EXISTING PARTITION WAS
REMOVED
GLAZING AS SPECIFIED
FIRE-RETARDANT WOOD
BLOCKING AS REQUIRED
SCALE:
STOREFRONT CORNER4
A8.5 A8.5
3" = 1'-0" 084113-04
ALUMINUM-FRAMED
STOREFRONT SYSTEM
GLAZING AS SPECIFIED
SCALE:
ENTRANCE DOOR SILL5
A8.1, A8.5 A8.5
3" = 1'-0" 084113-05
ALUMINUM ENTRANCE
DOOR AS SCHEDULED
10" ADA BOTTOM RAIL
GLAZING AS SPECIFIED
FLOOR FINISH AS
SCHEDULED, TYPICAL
RESILIENT TRANSITIONAL
MOULDING
101
103
105
104
106
107
108
1S
T F
LO
OR
ACT ACOUSTICAL CEILING TILE
CPT CARPET TILE
CWT CERAMIC WALL TILE
EXIST EXISTING TO REMAIN
EXP EXPOSED TO STRUCTURE
ABOVE
GWB GYPSUM WALLBOARD
LVT LUXURY VINYL TILE
MRB MOLD & MOISTURE
RESISTANT GWB
ROOM FINISH ABBREVIATIONS
ROOM FINISH GENERAL NOTES
A. WHERE CEILING HEIGHT IS INDICATED AS "VARIES" OR THERE ARE TWO
HEIGHTS INDICATED, REFER TO REFLECTED CEILING PLAN FOR REQUIRED
HEIGHTS.
B. REFER TO SHEET A10.1 FOR MARKING AND IDENTIFICATION FOR FIRE AND
SMOKE PROTECTION.
C. PAINT ALL EXISTING GYPSUM WALLBOARD (WALLS, SOFFITS & CEILINGS)
LOCATED IN AREAS UNDER RENOVATION.
D. WHERE EXISTING ACOUSTICAL CEILING PANELS AND SUSPENSION SYSTEMS
HAVE BECOME DAMAGED FROM SELECTIVE DEMOLITION OPERATIONS,
REPLACE WITH NEW TO MATCH EXISTING.
E. COORDINATE THE LOCATION OF ALL PAINT COLORS WITH ARCHITECT PRIOR
TO INSTALLATION.
ROOM FINISH KEY NOTES
1. PROVIDE CONTINUOUS 3/4" X 8'-0" A-C GRADE FIRE-RETARDANT PLYWOOD
PANELS ALONG WALLS WHERE INDICATED. SET BOTTOM EDGE OF PANELS
12" ABOVE FINISH FLOOR AND INSTALL WITH A-SIDE OF PANEL EXPOSED TO
ROOM. FINISH PLYWOOD WITH FIRE-RETARDANT PAINT AS SPECIFIED.
2. IN THE CENTRAL ATRIUM LOCATED ABOVE WAITING 101 (ADJACENT TO THE
ELEVATOR SHAFT), PAINT ALL NORTH AND SOUTH WALLS UP TO THE 2ND
FLOOR DECK. THE EXISTING PAINT FINISH ON THE EAST WALL OF THE
CENTRAL ATRIUM AT THE 2ND FLOOR DECK AND ALL ATRIUM WALLS
LOCATED ABOVE THE 2ND FLOOR CEILING SHALL REMAIN AS IS.
3. IN THE FRONT ATRIUM LOCATED JUST INSIDE THE MAIN ENTRANCE ON THE
WEST SIDE OF THE BUILDING, PAINT ALL WALLS UP TO THE 3RD FLOOR
(INCLUDING WALLS AT 2ND, 3RD AND MID-FLOOR LANDINGS). PAINT THE
GYPSUM WALLBOARD AT THE UNDERSIDE OF ALL FLIGHTS OF STAIRS.
COORDINATE PAINT COLORS, LOCATIONS AND EXTENTS WITH ARCHITECT
PRIOR TO INSTALLATION.
4. PROVIDE CONTINUOUS 1X6 WOOD CHAIR RAIL AROUND PERIMETER OF
ROOM. CHAIR RAIL TO HAVE PAINT FINISH.
5. PAINT ALL EXISTING STAIRTOWER WALLS FROM THE FIRST FLOOR ALL THE
WAY UP TO THE ROOF.
6. THE GYPSUM BOARD WALLS SURROUNDING THE ELEVATOR SHAFT
(INCLUDING THE WEST WALL OF MEETING 105) SHALL BE FINISHED WITH AN
ACCENT PAINT AS SPECIFIED. SEE INTERIOR ELEVATIONS 5 THRU 8 ON
SHEET A6.5.
P PAINT
PMT PORCELAN MOSAIC TILE
PLAM PLASTIC LAMINATE
PLWD PLYWOOD
RFT RECYCLED RUBBER
FLOOR TILE
RWB RUBBER WALL BASE
SC SEALED CONCRETE
TBP TILE BACKING PANEL
VCT VINYL COMPOSITION TILE
RO
OM
N
UM
BE
R
FIN
IS
H
MA
TE
RIA
L
WALLS
NORTH
BA
SE
MA
TE
RIA
L
CEILING
ROOM FINISH SCHEDULE
RO
OM
N
AM
E
FL
OO
R
FIN
IS
H
MA
TE
RIA
L
EAST
FIN
IS
H
MA
TE
RIA
L
SOUTH
FIN
IS
H
MA
TE
RIA
L
WEST
FIN
IS
H
HE
IG
HT
REMARKS
WAITING
102 INTAKE
INTAKE
FOYER
MEETING ROOM
WOMEN
MEN
EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
CORRIDOR
109
DOH (DEPARTMENT OF HEALTH)110
111 OFFICE
112 OFFICE
113 OFFICE
114
115
DOH IT EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
116
117
CORRIDOR
118 BREAK ROOM
119
EXIST EXIST -
120
121 CORRIDOR
122 JANITOR EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
123 MEN
124 WOMEN
EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
125 STAIRS
EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
EXIST EXIST -EXIST EXIST EXIST P EXIST P EXIST P EXIST P
126 SHOWER ROOM EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
127 OFFICE
128 OFFICE
129 CORRIDOR
130 OFFICE
131
132
133
134
135
136
137
138
139
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
140 ELECTRICAL
141 CORRIDOR
EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
142 CORRIDOR
143 CORRIDOR
144 BREAK ROOM EXIST EXIST -EXIST EXIST EXIST P EXIST P EXIST P EXIST P
145 CORRIDOR
146 CORRIDOR
147 OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
148
149
150
151
152
153 CORRIDOR
154 MECHANICAL ROOM
155 FOYER
EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
TRAINING ROOM
157 JANITOR
158 WOMEN
159 MEN
160 STAIRS
EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
EXIST EXIST -EXIST EXIST EXIST P EXIST P EXIST P EXIST P
161 COMMUNICATIONS ROOM EXIST EXIST -EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
162 CORRIDOR
163 OFFICE
164 OFFICE
CORRIDOR165
166
167
168
OFFICE
OFFICE
OFFICE
EXIST EXIST -CPT RWB EXIST P EXIST P EXIST P EXIST P
EXIST PGWB/EXIST PEXIST P EXIST EXIST -GWB/EXIST PCPT/LVT RWB
CPT RWB
CPT RWB
CPT/LVT RWB
- -
GWB P GWB P GWB P GWB P EXIST EXIST -
GWB P GWB P GWB/EXIST P EXIST P EXIST EXIST -
EXIST -EXIST
CPT RWB EXIST P- - - - GWB P 9'-0"
EXIST P EXIST PGWB/EXIST P - -
CPT RWB - - GWB/EXIST P GWB P GWB P EXIST EXIST -
CPT RWB P EXIST P EXIST P P EXIST EXIST -
CPT RWB
CPT RWB
CPT RWB
CPT RWB
EXIST EXIST -
EXIST EXIST -
EXIST EXIST -
EXIST EXIST -
EXIST P
GWB P
GWB P
P
EXIST P
GWB P
P
GWB P
EXIST P
GWB P
P
GWB P
EXIST P EXIST PGWB P GWB P
CPT RWB GWB P GWB P GWB PPGWB/EXIST EXIST EXIST -
LVT RWB PGWB/EXIST GWB P EXIST P EXIST P
CPT RWB GWB P EXIST P EXIST P GWB P EXIST EXIST -
CPT RWB GWB P GWB P EXIST P EXIST P EXIST EXIST -
CPT RWB EXIST P EXIST P GWB P GWB P EXIST EXIST -
CPT RWB EXIST PGWB P GWB P GWB P EXIST EXIST -
CPT RWB EXIST PGWB P GWB P GWB P EXIST EXIST -
CPT RWB EXIST PGWB P GWB P GWB P EXIST EXIST -
CPT RWB EXIST PGWB P GWB P GWB P EXIST EXIST -
CPT RWB EXIST PGWB P GWB P GWB P EXIST EXIST -
CPT RWB GWB P GWB P GWB P GWB P EXIST EXIST -
CPT RWB GWB P GWB P GWB P GWB P EXIST EXIST -
CPT RWB GWB P GWB P GWB P GWB P EXIST EXIST -
CPT RWB GWB P GWB P GWB P GWB P EXIST EXIST -
CPT RWB EXIST P EXIST PGWB P GWB P EXIST EXIST -
CPT RWB EXIST P GWB P GWB P - - EXIST EXIST -
EXIST EXIST -GWB PCPT RWB GWB P GWB P EXIST P
CPT RWB GWB P EXIST P GWB PGWB P EXIST/ACT1 EXIST/- -
CPT RWB PGWB/EXIST PGWB/EXIST EXIST PGWB P EXIST EXIST -
GWB P EXIST EXIST -GWB PGWB PGWB PCPT RWB
CPT RWB GWB P GWB PEXIST PEXIST P EXIST EXIST -
CPT RWB
CPT RWB
CPT RWB
CPT RWB
CPT RWB
EXIST EXIST -
EXIST EXIST -
EXIST EXIST -
EXIST EXIST -
EXIST EXIST -
EXIST EXIST -CPT RWB
GWB P GWB P GWB PPGWB
GWB P GWB P GWB P GWB/EXIST P
GWB P EXIST P GWB P GWB P
EXIST P GWB P GWB PGWB P
EXIST P EXIST P EXIST PGWB P
PGWB/EXIST PGWB/EXISTGWB P GWB P
CPT RWB P PPGWB/EXIST PGWB/EXIST GWB/EXISTGWB/EXIST EXIST EXIST -
CPT RWB EXIST P GWB PPGWB/EXIST GWB P ACT2/EXIST - -
SC RWB MRB P MRB P MRB P MRB P MRB P +9'-0"
CPT RWB
CPT RWB
CPT RWB
CPT RWB
CPT RWB
CPT RWB
CPT RWB
PGWB GWB P GWB P GWB P EXIST EXIST -
EXIST P EXIST P PGWB GWB P EXIST EXIST -
EXIST P EXIST PGWB PGWB P EXIST EXIST -
GWB P GWB P GWB P GWB P EXIST EXIST -
EXIST PGWB P GWB P GWB P EXIST EXIST -
GWB P GWB P GWB P EXIST EXIST -
EXIST PGWB P GWB P GWB P EXIST EXIST -
171 STORAGE CPT RWB GWB P GWB P GWB P GWB P +8'-0"GWB P
156 SEE NOTE 4
STORAGE
STORAGE
RWB
RWB
RWB
GWB
GWB
P
P
GWB
GWB
P
P
GWB
GWB
P
P
GWB
GWB
P
P
9'-0"
9'-0"
CORRIDOR CPT RWB GWB P PGWB/EXIST P GWB P EXIST EXIST -
GWB/EXIST GWB/EXIST
GWB/EXIST
109A
SCANNING
COPY CPT RWB
GWB/EXIST GWB/EXIST
EXIST P GWB P GWB P PGWB/EXIST EXIST EXIST -
PLAN ROOM CPT RWB GWB P GWB P GWB P GWB P EXIST/GWB EXIST/P VARIES
CPT
CPT
169 OFFICE CPT RWB GWB P GWB P GWB P EXIST EXIST -
GWB P
GWB P
GWB P
GWB P
GWB/EXIST
SEE NOTES 2, 3 & 6
SEE NOTE 5
SEE NOTE 5
SEE NOTE 6
170 OFFICE CPT RWB EXIST PGWB P GWB P GWB P EXIST EXIST -
A9.1
ROOM
FIN
ISH
SCHE
DULE
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
COPYLOC. TYPE QTY.
INTERIOR SIGNAGE SCHEDULE - 1ST FLOOREXIT104 1
SIGNAGE GENERAL NOTESA. SEE SHEETS A1.4, A2.4 & A3.4 FOR SIGNAGE PLANS.
B. SEE SHEET A10.2 FOR SIGN PLACEMENT GUIDANCE.
C. SEE SHEETS A10.2 AND A10.3 FOR SIGN TYPE DETAILS.
D. PRIOR TO FABRICATION, CONTRACTOR TO SUBMIT SIGNAGE
SCHEDULE TO OWNER/USER/ACTIVITY FOR FINAL REVIEW AND
APPROVAL OF ALL ROOM NUMBERS AND NAMES.
E. WHERE PANEL SIGNS ARE MOUNTED ON GLASS VISION OR SIDE
LIGHTS, PROVIDE BACK PANEL ON OPPOSITE SIDE OF GLASS
TO CONCEAL MOUNTING.
F. WHERE A PANEL SIGN IS INDICATED TO BE INSTALLED ON ONE
LEAF OF A PAIR OF EXISTING DOORS, THE DESIGN INTENT IS
FOR THE SIGN TO BE INSTALLED ON THE INACTIVE LEAF.
BB2105 1 105 MEETING ROOM
106 BB7
107
111
109
110
BB7
1
1
BB2 1
BB2 1
(PICTOGRAM: WOMAN, ACCESSIBILITY) WOMEN
BB2 1
MARKING & IDENTIFICATION FORSMOKE AND FIRE PROTECTION
1. MARKING AND IDENTIFICATION OF FIRE WALLS, FIRE BARRIERS,
FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS
OR ANY OTHER NEW WALL REQUIRED TO HAVE PROTECTED
OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND
PERMANENTLY IDENTIFIED WITH STENCILING ABOVE ANY
DECORATIVE CEILING AND IN CONCEALED SPACES WITH THE
WORDING "FIRE AND SMOKE BARRIER - PROTECT ALL
OPENINGS," OR SIMILAR LANGUAGE. METAL, PLASTIC OR PAPER
DECAL SIGNS ARE NOT ACCEPTABLE.
2. REFER TO LIFE SAFETY PLAN SHEETS LS1.1, LS2.1 & LS3.1 FOR
LOCATIONS OF ANY APPLICABLE FIRE WALLS, FIRE BARRIERS,
FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS.
3. IN FINISHED AREAS THAT DO NOT HAVE DROP CEILINGS (E.G.
STAIRWELLS, OFFICES, LOBBIES, CORRIDORS), DO NOT
PROVIDE STENCILING FOR AESTHETIC REASONS.
4. IDENTIFICATION SHALL BE LOCATED IN ACCESSIBLE
CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACES.
5. IN MECHANICAL, ELECTRICAL AND OTHER SIMILAR ROOMS THAT
DO NOT HAVE DROP CEILINGS, PLACE STENCILING AT 8-FEET
MINIMUM ABOVE FINISH FLOOR AND SPACE AT INTERVALS NOT
EXCEEDING 15 FEET ON-CENTER MEASURED HORIZONTALLY
ALONG WALL OR PARTITION.
6. IN AREAS WITH DROP CEILINGS, PROVIDE STENCILS NOT MORE
THAN 15-FEET ON CENTER ABOVE THE CEILING ALONG THE
ENTIRE LENGTH OF WALL.
7. PROVIDE ONE STENCIL ON EACH SEGMENT OF WALL 15-FEET
OR SHORTER IN LENGTH.
8. WHERE WALL CHANGES DIRECTION ON THE BLIND SIDE OF THE
WALL, PLACE A VERTICAL STRIPE AND THE WORD "END" TO
SIGNIFY THE WALL IS CHANGING DIRECTIONS.
9. STENCILING SHALL BE NEAT AND IN 4-INCH HIGH LETTERS, 1/2
INCH STROKE, AND BOLD RED COLOR. TAKE CARE WHEN
APPLYING PAINT TO PREVENT OVER-SPRAY ONTO ADJACENT
FINISHES.
10. CONFIRM EXACT WORDING WITH BUILDING/FIRE INSPECTOR
BEFORE APPLYING.
(PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT
(PICTOGRAM: MAN, ACCESSIBILITY) MEN
109 SCANNING
112
113
114
BB2A 1
BB2A 1
BB2A 1
110 HEALTH DEPARTMENT
111 HEALTH DEPARTMENT
112
113
114 COMMUNICATIONS ROOM
117 BB2 2 117 PLAN ROOM
118 BB2 1 118 BREAK ROOM
119 BB2 1 119 STORAGE
120 BB2 1
121 EXIT 1 (PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT
122 BB2 1 122 JANITOR
123 BB7 1 (PICTOGRAM: MAN, ACCESSIBILITY) MEN
124 BB7 1 (PICTOGRAM: WOMAN, ACCESSIBILITY) WOMEN
125 EXIT 1 (PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT
126 BB7 1 (PICTOGRAM: WOMAN, MAN) 126 SHOWER
127 BB2A 1 127
128 BB2A 1 128
130 BB2A 1 130
131 BB2A 1 131
132 BB2A 1 132
133 BB2A 1 133
134 BB2A 1 134
135 BB2A 1 135
136 BB2A 1 136
137 BB2A 1 137
138 BB2A 1 138
139 BB2A 1 139
140 BB2 1 140 ELECTRICAL ROOM
144 BB2 1 144 BREAK ROOM
147 BB2A 1 147
148 BB2A 1 148
149 BB2A 1 149
150 BB2A 1 150
151 BB2A 1 151
152 BB2A 1 152
154 BB2 1 154 MECHANICAL ROOM
155 EXIT 1 (PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT
156 CNF 2 156 TRAINING ROOM
156 OCP 1 MAXIMUM OCCUPANT LOAD 58 PERSONS
157 BB2 1 157 JANITOR
158 BB7 1
(PICTOGRAM: MAN, ACCESSIBILITY) MEN159 BB7 1
(PICTOGRAM: WOMAN, ACCESSIBILITY) WOMEN
EXIT 1 (PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT160
161 BB2 1 161 COMMUNICATIONS ROOM
163 BB2A 1 163
164 BB2A 1 164
166 BB2A 1 166
167 BB2A 1 167
168 BB2A 1 168
169 BB2A 1 169
170 BB2 1 170
109A BB2 1 109A COPY ROOM
119 STORAGE
115 EXIT 1 (PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT
141 EXIT 1 (PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT
143 EXIT 1 (PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT
153 EXIT 1 (PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT
162 EXIT 1 (PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT
156 EXIT 2 (PICTOGRAM: PERSON EXITING THROUGH DOOR) EXIT
171 BB2 1 171 STORAGE
COPYLOC. TYPE QTY.
INTERIOR SIGNAGE SCHEDULE - STAIRWAYS125 1ST SOUTH STAIR (LINE 1)
FLOOR (LINE 2)
1 (LINE 3)
FLOOR 1 TO FLOOR 3 (LINE 4)
NO ROOF ACCESS (LINE 5)
FLOOR 1 (LINE 6)
FOR EXIT DISCHARGE (LINE 7)
160 1ST NORTH STAIR (LINE 1)
FLOOR (LINE 2)
1 (LINE 3)
FLOOR 1 TO FLOOR 3 (LINE 4)
NO ROOF ACCESS (LINE 5)
FLOOR 1 (LINE 6)
FOR EXIT DISCHARGE (LINE 7)
227 1ST SOUTH STAIR (LINE 1)
FLOOR (LINE 2)
2 (LINE 3)
FLOOR 1 TO FLOOR 3 (LINE 4)
NO ROOF ACCESS (LINE 5)
DOWN TO FLOOR 1 (LINE 6)
FOR EXIT DISCHARGE (LINE 7)
268 1ST NORTH STAIR (LINE 1)
FLOOR (LINE 2)
2 (LINE 3)
FLOOR 1 TO FLOOR 3 (LINE 4)
NO ROOF ACCESS (LINE 5)
DOWN TO FLOOR 1 (LINE 6)
FOR EXIT DISCHARGE (LINE 7)
320 1ST SOUTH STAIR (LINE 1)
FLOOR (LINE 2)
3 (LINE 3)
FLOOR 1 TO FLOOR 3 (LINE 4)
NO ROOF ACCESS (LINE 5)
DOWN TO FLOOR 1 (LINE 6)
FOR EXIT DISCHARGE (LINE 7)
338 1ST NORTH STAIR (LINE 1)
FLOOR (LINE 2)
3 (LINE 3)
FLOOR 1 TO FLOOR 3 (LINE 4)
NO ROOF ACCESS (LINE 5)
DOWN TO FLOOR 1 (LINE 6)
FOR EXIT DISCHARGE (LINE 7)
A10.1
INTE
RIOR
SIG
NAGE
SCH
EDUL
E
SAB
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A10.2
INTE
RIOR
SIG
NAGE
DET
AILS
SAB
SCALE:
ROOM IDENTIFICATION SIGN - TYPE BB22
A1.4, A2.4, A3.4, A10.1 A10.2
6" = 1'-0" 101400-02
6"
6"
144
BREAK
1/2"
5"
1/2"
1"
5/8"
1/2"
3/8"
ROOM NUMBER: HELVETICA,
1" NUMBERS, FLUSH LEFT
COPY: UPPER CASE
HELVETICA 5/8" CAPITAL
LETTER HEIGHT, FLUSH
LEFT
SIGN PANEL (SQUARE EDGES,
1/2" RADIUS CORNERS, NO FRAME)
GRADE 2 BRAILLE,
TYPICAL
ROOM
5/8"
1/2"
1/2"
5/8"
3/8"
MIN
.
SCALE:
ROOM IDENTIFICATION SIGN PLACEMENT1
A10.1 A10.2
1/2" = 1'-0" 101400-01
CLEAR FLOOR SPACE
CENTERED ON TACTILE
CHARACTERS
ADJACENT
SIDE WALL
SIGN, TYPICAL
CONDITION "A"
5'-1" (S
EE
N
OT
E 1)
SIGN
PUSH OR
PULL SIDE
CONDITION "B"
PUSH OR PULL SIDE
PUSH
SIDE
TO
P O
F S
IG
N
INACTIVE
LEAF
ACTIVE
LEAF
C
L
EQ. EQ.
1. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48
INCHES MINIMUM ABOVE FINISH FLOOR OR GROUND
SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST
TACTILE CHARACTER AND 60 INCHES MAXIMUM ABOVE THE
FINISH FLOOR OR GROUND SURFACE, MEASURED FROM
THE BASELINE OF THE HIGHEST CHARACTER.
2. TACTILE SIGNS SHALL BE LOCATED ALONGSIDE THE DOOR
AT THE LATCH SIDE. SEE CONDITION "A".
3. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS
WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON
THE INACTIVE LEAF. SEE CONDITION "B".
4. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS
WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO
THE RIGHT SIDE OF THE RIGHT HAND DOOR. SEE CONDITION
"C".
5. WHERE THERE IS EITHER NO WALL SPACE OR INSUFFICIENT
WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT
THE RIGHT SIDE OF DOUBLE DOORS WITH TWO ACTIVE
LEAFS, SIGNS SHALL BE LOCATED ON NEAREST ADJACENT
WALL. SEE CONDITION "D".
6. TACTILE SIGNS SHALL PER PERMITTED ON THE PUSH SIDE
OF DOORS WITH CLOSERS AND WITHOUT HOLD-OPEN
DEVICES. SEE CONDITION "E".
7. TACTILE SIGNS SHALL BE LOCATED SO THAT A CLEAR
FLOOR SPACE OF 18 INCHES MIN. BY 18" MIN., CENTERED ON
THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC
OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND
45 DEGREE OPEN POSITION.
8. IF THERE IS ANY QUESTION ABOUT PROPER INSTALLATION
OF SIGNS OR IF FIELD CONDITIONS DIFFER FROM THOSE
INDICATED IN THIS DETAIL, NOTIFY ARCHITECT FOR
ASSISTANCE.
CONDITION "C"
PUSH OR PULL SIDE
ACTIVE
LEAF
ACTIVE
LEAF
SIGN PLACEMENT NOTES
ACTIVE
LEAF
ACTIVE
LEAF
SEE NOTE 7
SIGN
CONDITION "D" CONDITION "E"
WITH CLOSER &
WITHOUT HOLD-OPEN
DEVICES
C
L
18"
18"
MIN.
MIN
.
4
5
°
C
L
EQ. EQ.
VA
RIE
S
C
L
6" TYPICAL
U.N.O. ON
SIGNAGE PLAN
6" TYPICAL
U.N.O. ON
SIGNAGE PLAN
5'-1" (S
EE
N
OT
E 1)
TO
P O
F S
IG
N
5'-1" (S
EE
N
OT
E 1)
TO
P O
F S
IG
N
5'-1" (S
EE
N
OT
E 1)
TO
P O
F S
IG
N
5'-1" (S
EE
N
OT
E 1)
TO
P O
F S
IG
N
SCALE:
ROOM IDENTIFICATION SIGN - TYPE BB2A3
A1.4, A2.4, A3.4, A10.1 A10.2
6" = 1'-0" 101400-03
6"
6"
112
1/2"
5"
1/2"
1"
1/2"
ROOM NUMBER: HELVETICA,
1" NUMBERS, FLUSH LEFT
WINDOW WITH 1/16" NON-GLARE
ACRYLIC FACE AND 7/8" MESSAGE
INSERT SLOT WITH SUBSURFACE
PAINTED TO MATCH SIGN PANEL
COLOR
SIGN PANEL (SQUARE EDGES,
1/2" RADIUS CORNERS, NO FRAME)
GRADE 2 BRAILLE
1/2"
3/4"
1/2"
NOTE: WINDOW INSERTS BY OWNER
SCALE:
SERVICE IDENTIFICATION SIGN - TYPE BB74
A1.4, A2.4, A3.4, A10.1 A10.2
6" = 1'-0" 101400-04
8"
8"
6"
COPY: UPPER CASE
HELVETICA, 5/8" CAPITAL
LETTER HEIGHT,
CENTERED
SIGN PANEL (SQUARE EDGES,
1/2" RADIUS CORNERS, NO
FRAME)
GRADE 2
BRAILLE
3/8"
1/2"
5/8"
WOMEN
PICTOGRAM, TYPICAL
PIC
TO
GR
AM
F
IE
LD
1/2" 1/2"
2"
MIN
.
1/8"
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A10.3
INTE
RIOR
SIG
NAGE
DET
AILS
SAB
SCALE:
ROOM IDENTIFICATION SIGN - TYPE CNF1
A1.4, A2.4, A10.1 A10.3
6" = 1'-0" 101400-05
9"
8"
119
CONFERENCE
1/2"
8"
1/2"
1"
5/8"
3/8"
3/8"
ROOM NUMBER: HELVETICA,
1" NUMBERS, FLUSH LEFT
COPY: UPPER CASE
HELVETICA 5/8" CAPITAL
LETTER HEIGHT, FLUSH
LEFT
SIGN PANEL (SQUARE EDGES,
1/2" RADIUS CORNERS, NO
FRAME)
GRADE 2 BRAILLE,
TYPICAL
ROOM
7/8"
1/2"
3/8"
5/8"
SLIDER WITH "IN USE" &
"VACANT" COPY
IN USE
3/8"
1 3/8"
VACANTUPPER CASE HELVETICA,
1/2" CAPITAL LETTER
HEIGHT
3/8"
MIN
.
SCALE:
OCCUPANT LOAD SIGN - TYPE OCP2
A1.4, A10.1 A10.3
6" = 1'-0" 101400-06
9"
MAXIMUM
1/2"
8"
1/2"
9"
1"
COPY:UPPER CASE
HELVETICA, 1" CAPITAL
LETTER HEIGHT,
CENTERED
3/4"
OCCUPANT
1"
3/8"
SIGN PANEL (SQUARE EDGES,
1/2" RADIUS CORNERS, NO
FRAME)
LOAD
1"
3/8"
59
1"
3/8"
PERSONS
1"
3/8"
1/2"
3/8"
MIN
.
GRADE 2 BRAILLE
SCALE:
OSHA DANGER SIGN - TYPE OSHA3
A3.4, A10.1 A10.3
6" = 1'-0" 101400-07
10"
7"
COPY:UPPER CASE
HELVETICA, 1" CAPITAL
LETTER HEIGHT,
CENTERED, BLACK
SIGN PANEL (SQUARE
EDGES & CORNERS, NO
FRAME, WHITE)
PERSONNEL ONLY
AUTHORIZED
1/2" 1/2"
3/4"
3/8"5
/8"
5/8"
WHITE LETTERS ON RED
OVAL BACKGROUND
BLACK
SCALE:
STAIRWAY IDENTIFICATION - 1ST FLOOR4
A10.1 A10.2
3" = 1'-0" 101400-08
1'-6" (SEE NOTE)
1'-4 5/8"
NORTH STAIR
FLOOR
1
NO ROOF ACCESS
FLOOR 1 TO FLOOR 3
1"
1"
5"
1"
1"
1"
1"
1/2"
3/4"
1/2"
1/2"
1/2"
7/8"
7/8"
3/4"1'-4 1/2"
3/4"
UPPER CASE HELVETICA
MEDIUM, 1" CAPITAL LETTER
HEIGHT, CENTERED
EL
BOTTOM OF PANEL
+4'-0" A.F.F.
FLOOR 1 FOR
EXIT DISCHARGE
3/8"
3/8"
NOTE: INCREASE WIDTH AS
NECESSARY TO
ACCOMMODATE TEXT
UPPER CASE HELVETICA
MEDIUM, 5" CAPITAL LETTER
HEIGHT, CENTERED
SIGN PANEL (SQUARE
EDGES, 1/2" RADIUS
CORNERS. NO FRAME)
GRADE 2 BRAILLE
3/8"
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A12.1
INTE
RIOR
DET
AILS
SAB
SCALE:
FIRE EXTINGUISHER CABINET1
LS1.1, L2.1, LS3.1, A0.1 A12.1
1" = 1'-0" 104413-01
4'-3"
SEMI-RECESSED FIRE
EXTINGUISHER CABINET WITH 4"
MAXIMUM PROJECTION
FINISH FLOOR
TO
P O
F C
AB
IN
ET
T
RIM
2
A12.1
SCALE:
FIRE EXTINGUISHER CABINET2
A12.1 A12.1
3" = 1'-0" 104413-02
GYPSUM WALLBOARD ON LIGHT
GAUGE METAL STUDS
MOUNTING SCREW PER
MANUFACTURER'S INSTALLATION
INSTRUCTIONS, TYPICAL
DOOR
DOOR HANDLE
SEMI-RECESSED
FIRE EXTINGUISHER
CABINET
FRAME RETURN TRIM
4" M
AX
.
VE
RIF
Y
DE
PT
H
SCALE:
FIRE EXTINGUISHER3
LS1.1, LS2.1, LS3.1, A0.1 A12.1
1" = 1'-0" 104416-01
NOTES:
1. LOCATE MOUNTING BRACKET ABOVE
FINISH FLOOR SO THAT TOP OF FIRE
EXTINGUISHER HANDLE WILL BE 47" ABOVE
FINISH FLOOR.
2. SEE LIFE SAFETY PLAN(S) AND FLOOR
PLAN(S) FOR REQUIRED LOCATIONS.
MOUNTING BRACKET AS SPECIFIED
FIRE EXTINGUISHER AS SPECIFIED
3'-11"
FINISH FLOOR
SCALE:
ACCESS DOOR @ GWB CEILING4
A0.1 A12.1
6" = 1'-0" 083113-01
FLUSH 14-GAGE STEEL
ACCESS PANEL
CONT. CONCEALED HINGE
FLUSH CAM LATCH
16-GA STEEL FRAME
1" X 1-9/16" X 1" KNURLED
CHANNEL MOLDING
5/8" GYPSUM WALLBOARD
ON EITHER DRYWALL
SUSPENSION SYSTEM OR
METAL STUD FRAMING
SCALE:
ACCESS DOOR @ GWB PARTITION5
A0.1 A12.1
6" = 1'-0" 083113-02
STAINLESS STEEL
CAM LATCH
16-GAGE STEEL DOOR
WITH RECESS TO RECEIVE
GYPSUM WALLBOARD
CONCEALED
HINGE
5/8" GYPSUM
WALLBOARD
12-GAGE STEEL
FRAME
DOOR SIZE AS REQUIRED
DRYWALL
COMPOUND
SCALE:
RESILIENT MOULDING6
A8.2 A12.1
6" = 1'-0" 096513-01
VINYL COMPOSITION TILE
RESILIENT TRANSITIONAL
MOULDING
CARPET TILE
DOOR AS SCHEDULED
SCALE:
RESILIENT MOULDING7
A8.3 A12.1
6" = 1'-0" 096513-02
CONCRETE FLOOR SLAB
RESILIENT TRANSITIONAL
MOULDING
CARPET TILE
DOOR AS SCHEDULED
SCALE:
INTERIOR WOOD WINDOW JAMB8
A6.2 A12.1
3" = 1'-0" 064800-01
CONTINUOUS SEALANT AROUND
PERIMETER OF FRAME, TYPICAL
EACH SIDE
1/4"
1X3 WOOD TRIM, TYPICAL
1/2" X 1" WOOD STOP, TYPICAL
1/4" CLEAR TEMPERED GLASS
CONT. 1" WOOD JAMB
1/4" WOOD SHIM
PARTITION AS SCHEDULED OR
NOTED
NOTE: HEAD AND SILL DETAIL ARE SIMILAR
SCALE:
INTERIOR WOOD WINDOW JAMB10
A6.7 A12.1
3" = 1'-0" 064800-03
1/4" TYP.
1X6 WOOD TRIM, TYPICAL
1/2" X 1" WOOD STOP, TYPICAL
1/4" CLEAR TEMPERED GLASS
CONT. 1" WOOD JAMB, TYPICAL
1/4" WOOD SHIM, TYPICAL
5/8" GYPSUM WALLBOARD ON
3-5/8" 20 GAUGE METAL STUDS
3 1/2"
4 7/8"
SCALE:
INTERIOR WOOD WINDOW JAMB9
A6.7 A12.1
3" = 1'-0" 064800-02
CONTINUOUS SEALANT AROUND
PERIMETER OF FRAME, TYPICAL
EACH SIDE
1/4"
1X6 WOOD TRIM, TYPICAL
1/2" X 1" WOOD STOP, TYPICAL
1/4" CLEAR TEMPERED GLASS
CONT. 1" WOOD JAMB
1/4" WOOD SHIM
5/8" GYPSUM WALLBOARD ON
3-5/8" 20 GAUGE METAL STUDS
4 5/8"
4 7/8"
SCALE:
INTERIOR WOOD WINDOW HEAD11
A6.7 A12.1
3" = 1'-0" 064800-04
1/4"
CONT. FLEX OR SLOTTED METAL
DEFLECTION TRACK
EXIST. PRE-STRESSED HOLLOW
CORE PLANK DECK
5/8" GYPSUM WALLBOARD ON 3-5/8"
20 GAUGE METAL STUDS AT 16" O.C.
MODIFY EXIST. CONCEALED SPLINE
CEILING SYSTEM TO ALLOW
INSTALLATION OF NEW PARTITION
1X4 WOOD TRIM, TYPICAL
CONT. 1" WOOD JAMB OVER 1/4"
WOOD SHIM
1/2" X 1" WOOD STOP, TYPICAL
1/4" CLEAR TEMPERED GLASS
2 5/8"
SCALE:
INTERIOR WOOD WINDOW SILL12
A6.7 A12.1
3" = 1'-0" 064800-05
1/4"
5/8" GYPSUM WALLBOARD ON 3-5/8"
20 GAUGE METAL STUDS AT 16" O.C.
1X4 WOOD TRIM, TYPICAL
CONT. 1" WOOD JAMB OVER 1/4"
WOOD SHIM
1/2" X 1" WOOD STOP, TYPICAL
1/4" CLEAR TEMPERED GLASS
2 5/8"
CONTINUOUS SEALANT AROUND
PERIMETER OF FRAME, TYPICAL
EACH SIDE
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A12.2
INTE
RIOR
DET
AILS
SAB
SCALE:
PLAS. LAMINATE-FACED CABINETS1
A6.6 A12.4
1 1/2" = 1'-0" 064116-01
DRAWER
4"
2'-10"
1'-8"
2'-6"
1 1/2"
2'-1"
1'-1"
3/4" DOOR PANEL WITH PULL
1/4" BACK PANEL
3/4" ADJUSTABLE SHELF (1" IF
OVER 30" IN LENGTH)
3/4" BACKSPLASH
PLASTIC LAMINATE
COUNTERTOP
3/4" DRAWER PANEL
WITH PULL
3/4" DOOR PANEL
WITH PULL
3/4" ADJUSTABLE SHELF
(1" IF OVER 30" IN LENGTH)
1/2" BACK PANEL
SLEEPER
7'-0"
(A
CC
ES
SIB
LE
H
EIG
HT
)
1'-11 1/2"
3"
BACKING PLATE, FLEXIBLE WOOD
BACKING SYSTEM OR 2X6
FIRE-RETARDANT WOOD
BLOCKING AS REQUIRED FOR
APPLICABLE LOADS, TYPICAL
1 1/2"
4"
TOE KICK WITH WALL
BASE AS SCHEDULED
SCALE:
PLAS. LAMINATE-FACED CABINETS2
A6.6 A12.4
1 1/2" = 1'-0" 064116-02
4"
2'-10"
1 1/2"
2'-1"
3/4" BACKSPLASH
PLASTIC LAMINATE
COUNTERTOP
FALSE FRONT PANEL
3/4" DOOR PANEL
WITH PULL
1/2" BACK PANEL
SLEEPER
7'-0"
(A
CC
ES
SIB
LE
H
EIG
HT
)
1'-11 1/2"
3"
1 1/2"
4"
TOE KICK WITH WALL
BASE AS SCHEDULED
DROP-IN SINK - SEE
PLUMBING DRAWINGS
2'-6"
1'-1"
3/4" DOOR PANEL WITH PULL
1/4" BACK PANEL
3/4" ADJUSTABLE SHELF (1" IF
OVER 30" IN LENGTH)
BACKING PLATE, FLEXIBLE WOOD
BACKING SYSTEM OR 2X6
FIRE-RETARDANT WOOD
BLOCKING AS REQUIRED FOR
APPLICABLE LOADS, TYPICAL
1'-8"
1'-8"
2'-6"
1'-1"
3/4" DOOR PANEL WITH PULL
1/4" BACK PANEL
3/4" ADJUSTABLE SHELF (1" IF
OVER 30" IN LENGTH)
7'-0"
BACKING PLATE, FLEXIBLE WOOD
BACKING SYSTEM OR 2X 6
FIRE-RETARDANT WOOD
BLOCKING AS REQUIRED FOR
APPLICABLE LOADS, TYPICAL
DRAWER
4"
2'-10"
1 1/2"
3/4" DRAWER PANEL
WITH PULL, TYPICAL
1/4" BACK PANEL
SLEEPER
(A
CC
ES
SIB
LE
H
EIG
HT
)
3"
4"
TOE KICK WITH WALL
BASE AS SCHEDULED
DRAWER
DRAWER
DRAWER
3 E
QU
AL
2'-1"
3/4" BACKSPLASH
PLASTIC LAMINATE
COUNTERTOP
1'-11 1/2" 1 1/2"
SCALE:
PLAS. LAMINATE-FACED CABINETS3
A6.2, A6.6, A6.7 A12.2
1 1/2" = 1'-0" 0641160--03
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A12.3
INTE
RIOR
DET
AILS
SAB
SCALE:
PLAS. LAMINATE-FACED CABINET1
A6.3 A12.3
1 1/2" = 1'-0" 064116-10
4"
2'-6"
6"
3'-0"
DRAWER
1 1/2"
PLASTIC LAMINATE
COUNTERTOP
3/4" DRAWER PANEL
WITH PULL, TYPICAL
1/2" BACK PANEL
SLEEPER
1'-11 1/2"
3"
1 1/2"
TOE KICK WITH
PLASTIC LAMINATE
DRAWER
FILE
DRAWER
TEMPERED GLASS HEADER
PANEL (BEYOND)
SCALE:
PLAS. LAMINATE-FACED PARTITION2
A6.3 A12.3
1 1/2" = 1'-0" 064116-10
4'-0"
PLASTIC LAMINATE-FACED
PARTITION WITH 2X4 WOOD STUDS
AT 16" O.C. WITH 3/4" PLYWOOD
SHEATHING BOTH SIDES
TEMPERED GLASS HEADER
PANEL (BEYOND)
3/4" PANEL, TYPICAL
2'-1"
5"
2X4 WOOD, TYPICAL
2X4 WOOD STUDS
AT 16" O.C. MAX.
2'-8"
8"
WIRE RACEWAY, TYPICAL
TEMPERED GLASS DIVIDER
PANEL
ALUMINUM GLASS RAILING
EXTRUSION
SWIVEL FITTING, TYPICAL (EQUAL
TO CRL COLUMN SERIES)
SCALE:
PLAS. LAMINATE-FACED PARTITION 3
A6.3, A6.4 A12.3
1 1/2" = 1'-0" 064116-10
4'-0"
PLASTIC LAMINATE-FACED
PARTITION WITH 2X4 WOOD STUDS
AT 16" O.C. WITH 3/4" PLYWOOD
SHEATHING BOTH SIDES
3'-4"
WIRE RACEWAY, TYPICAL
TEMPERED GLASS DIVIDER
PANEL
ALUMINUM GLASS RAILING
EXTRUSION
1" REVEAL, TYPICAL
1'-2 5/16"
1"
1'-3 5/16"
1"
1'-4 5/16"
TEMPERED GLASS DIVIDER
PANEL (BEYOND)
SCALE:
PLAS. LAMINATE-FACED CABINET5
A6.3, A6.5 A12.3
1 1/2" = 1'-0" 064116-11
4"
2'-6"
1 1/2"
PLASTIC LAMINATE
COUNTERTOP
3/4" DRAWER PANEL
WITH PULL, TYPICAL
1'-10 1/2"
3"
1 1/2"
TOE KICK WITH
PLASTIC LAMINATE
3'-0"
1'-0"
3"
3/4" PANEL, TYPICAL
WIRE RACEWAY,
TYPICAL
DRAWER
SLEEPER
DRAWER
FILE
DRAWER
SCALE:
PLAS. LAMINATE COUNTERTOP4
A6.3, A6.4 A12.3
1 1/2" = 1'-0" 064116-12
2'-6"
1 1/2"
PLASTIC LAMINATE
COUNTERTOP
1'-7"
3'-0"
1'-0"
3"
3/4" PANEL, TYPICAL - PROVIDE
REMOVABLE PANELS AS NECESSARY TO
FACILITATE INSTALLATION OF
ELECTRICAL CONDUIT AND WIRING
2X4 WOOD
BLOCKING, TYPICAL
2X2 WOOD
BLOCKING, TYPICAL
5"
WIRE RACEWAY,
TYPICAL
3'-5"
4"
1 1/2"
BACKING PLATE, FLEXIBLE WOOD
BACKING SYSTEM OR 2X6
FIRE-RETARDANT WOOD BLOCKING
AS REQUIRED FOR APPLICABLE
LOADS
CONT. 1X4 WOOD LEDGER
- PAINT TO MATCH WALL
1-1/2" THICK PLASTIC
LAMINATE SUPPORT PANEL
SCALE:
PLAS. LAMINATE COUNTERTOP6
A6.6 A12.3
1 1/2" = 1'-0" 064116-05
NO
T T
O S
CA
LE
3'-0"
PLASTIC LAMINATE COUNTERTOP
WITH 3/4" BACKSPLASH
SCALE:
PLAS. LAMINATE-FACED CABINET7
A6.6 A12.3
1 1/2" = 1'-0" 064116-15
DRAWER
4"
3'-5"
1 1/2"
3'-0"
PLASTIC LAMINATE
COUNTERTOP WITH
3/4" BACKSPLASH
3/4" DRAWER PANEL
WITH PULL
3/4" DOOR PANEL
WITH PULL
3/4" ADJUSTABLE
SHELF (1" IF OVER
30" IN LENGTH)
1/2" BACK PANEL
SLEEPER
2'-10 1/2"
3"
1 1/2"
4"
TOE KICK WITH WALL
BASE AS SCHEDULED
NO
T T
O S
CA
LE
Eber
t Nor
man
Bra
dy13
61 13
th Av
enue
Sou
th, S
uite 2
30
Jack
sonv
ille B
each
, Flor
ida 32
250
Tel 9
04.24
1.999
7 F
ax 90
4.241
.7526
w
ww.en
barch
itects
.com
Arch
itects
PROJECT NO.
15056
ISSUE DATE :
REVISIONS :
ST. J
OHNS
COU
NTY
BUILD
ING
SERV
ICES
RENO
VATI
ON &
REM
ODEL
ING
- FIR
ST F
LOOR
ST
. A
UG
US
TIN
E, F
L
DRAWN BY:
AA00
0298
6
IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY
ISSUED FOR BID
NOT FOR
CONSTRUCTION
02/12/18
A12.4
INTE
RIOR
DET
AILS
SAB
SCALE:
PLAS. LAMINATE-FACED CABINET1
A6.6 A12.2
1 1/2" = 1'-0" 064116-14
4"
1/4" BACK PANEL
3/4" ADJUSTABLE SHELF (1" IF
OVER 30" IN LENGTH)
3"
TOE KICK WITH WALL
BASE AS SCHEDULED
5'-6 3/4"
SLEEPER
1" ADJUSTABLE
SHELF, TYPICAL
3/4" BACK PANEL
3'-6"
2'-0 3/4"
1'-4"
1 1/2"
2'-8"
2'-7"
1"
BACKING PLATE, FLEXIBLE WOOD
BACKING SYSTEM OR 2X6
FIRE-RETARDANT WOOD
BLOCKING AS REQUIRED FOR
APPLICABLE LOADS, TYPICAL
SCALE:
PLAS. LAMINATE-FACED SECURITY DESK3
A6.5 A12.4
1 1/2" = 1'-0" 0641160--13
PLASTIC LAMINATE
COUNTERTOP, TYPICAL
6 1/4"
1'-0 1/16"
1'-0 1/16"
1'-0 1/16"
1"
1 1/2"
1"
1"
1"
3/4" PANEL, TYPICAL
4'-0"
REVEAL WITH PLASTIC
LAMINATE FINISH
3/4" T&G PLYWOOD ON 2X6
WOOD JOISTS AT 16" O.C. MAX.
LVT FLOOR FINISH AS SCHEDULED
OVER 3/4" TONGUE & GROOVE
PLYWOOD SUBFLOOR ON 2X6 P.T.
WOOD JOISTS AT 16" O.C. MAX.
WALL BASE AS
SCHEDULED
1 1/2"
2'-6"
2'-4"
2'-10"
8"2'-2"
EXISTING WALL
3'-4"
1"
6'-2"
COORDINATE POWER & DATA
WITH ELEC. SUBCONTACTOR
- SEE ELECTRICAL DRAWINGS
FOR POWER & DATA OUTLET
LOCATIONS
OVAL WIRE MANAGEMENT
GROMMENT (MOCKETT LO3-90),
TYPICAL - CENTER ON DESK
SCALE:
PLAS. LAMINATE-FACED CABINET2
A6.5 A12.4
1 1/2" = 1'-0" 064116-16
4"
2'-6"
1'-8"
1 1/2"
2'-1"
1'-1"
1/4" BACK PANEL
3/4" FIXED SHELF, TYPICAL
PLASTIC LAMINATE
COUNTERTOP
3/4" DOOR PANEL
WITH PULL
3/4" ADJUSTABLE SHELF
(1" IF OVER 30" IN LENGTH)
1/2" BACK PANEL
SLEEPER
4'-4"
10 1/2"
3"
BACKING PLATE, FLEXIBLE WOOD
BACKING SYSTEM OR 2X6
FIRE-RETARDANT WOOD
BLOCKING AS REQUIRED FOR
APPLICABLE LOADS, TYPICAL
1 1/2"
4"
TOE KICK WITH WALL
BASE AS SCHEDULED