Post on 21-Oct-2020
transcript
Photo reactor
CIS Cooled injection system
MCS Multi Column Switching
Graphpack
SLH Septum less head
TDS Thermodesorption System
SBSE GERSTEL Twister Technique
TC Tube Conditioner
TE Thermal Extractor
TDU Thermal Desorption Unit
MPS Multi Purpose Sampler
MAESTRO Software
DHS Dynamic Headspace
2016
Unlimited
possibilities
We bring
the right
pieces
together!
We bring
the right
pieces
together!
We bring
the right
pieces
together!
We bring
the right
pieces
together!
We bring
the right pieces
together for
your current
needs!
Future-proof
for new
application
requests
Through
modular
upgrade
of existing
system
Unlimited
possibilities
Perfect Fit!
GERSTEL GmbH & Co. KG
Germany GERSTEL AG
Switzerland
GERSTEL K.K.
Japan
GERSTEL LLP
Singapore
GERSTEL, Inc.
USA
GERSTEL Brasil
Brazil
worldwide
Novedades!
GERSTEL-MPS robotic
MPS robotic
• Autosampler and sample preparation robot for GC/MS and
LC/MS
– Multifunctional sample preparation platform and long-term
secure investment allowing
modular expansion as needs arise
MPS robotic
• Improved sample capacity and throughput
– Extended tray holders
– Improved utilization of tray space
– Full productivity can be maintained
overnight and on weekends
• Fast Split/Splitless Injection
– Reliable results thanks to efficient
discrimination-free analyte transfer even
when using hot injection port
MPS robotic
• Universal Syringe Module
GERSTEL USM
– The USM module accepts liquid
syringes from 1 to 1000 µL.
– Future proof: Only the USM is
compatible with the GERSTEL
gripper enabling a full range of
sample prep techniques
MPS roboticpro
• Extended robotic functionalities
– Reliable processing of complex sample preparation due to integrated power feedback for every step and every movement
• Bottom Vial Sensing enables µL Injections from very small sample volumes
– Reliable results even from small sample volumes
– Improved concentration factor can be achieved, for example by using a smaller solvent volume for extraction or SPE
MPS roboticpro
• MPS Tool Exchange
– High degree of flexibility
– Automated tool change within
method or sequence
(liquid /SPME /HS)
GERSTEL MPS liquid
MPS liquid
• New member of the MPS family
– Dedicated liquid autosampler for GC (GC/MS) and
LC (LC/MS)
– Fast and highly reliable technology from the MPS
robotic series
MPS liquid
• Liquid Sample Preparation
– Extremely simple and intuitive addition of sample preparation
steps thanks to the MAESTRO Software
– Identical treatment of all samples: Sample preparation and
derivatization are performed immediately before sample
introduction for better more uniform analysis results
MPS liquid
• Productive, flexible autosampler
– Priority samples can be added at any point without pausing or
stopping the ongoing analysis sequence
– Modular expansion and easy adaptation to changing analysis
requirements
– Processing of all standard autosampler vials as well as Micro- and
Deepwell Plates
– Reading and processing of 1D- and 2D barcodes
– Reliable results thanks to optimized, discrimination free sample
introduction using fast Split/Splitless injection to hot inlet
GERSTEL Thermal Desorption Unit
Multifunctional Thermal Desorption Unit TDU 2
DHS
Dynamic Headspace
Twister desorption
ATEX
Thermal
Extraction of
liquids in µ-vials
Thermal Desorption of
Adsorbent tubes Thermal
Extraction
of solids
MPS HIT
SPME, Headspace- and liquid
introduction in two stage
PTV-system with cryo-trapping
PYRO
Pyrolysis of solids and liquids
TDU 2
TDU 2
• Universal Thermal Desorption Unit
– Multiple techniques performed without reconfiguration:
• Dynamic Headspace
• Twister Desorption
• Thermal Extraction of liquids and solids
• Thermal Desorption of adsorbent tubes
– Fast change to CIS/PTV operation and liquid introduction
TDU 2
• Simple installation, easy and
reliable CIS liner exchange
• Standard Low-Split Option
– For VVOCs
TDU 2
• TDU Park Station
– Fast and easy Mounting
and Deinstallation
– Secure positioning and
storage of the TDU while
not in use
TDU 2
Universal Thermal
Desorption Unit
TDU liner with frit for thermal
extraction of solid samples
TDU liner packed with adsorbent
TDU liner for Twister desorption
TDU liner for thermal extraction in µ-vials
TDU 2
• Inert Liner-in-Liner system
– Perfect analyte recovery, active sites are eliminated
– Reliable results, memory effects are eliminated
– Best possible analyte transfer through short heated path
TDU 2
Cooled Injection System CIS
Thermal Desorption Unit TDU
TDU tube
TDU 2
• Desorption tubes stored in sealed tray positions
– Reliable results
– Contamination through laboratory air is prevented
– Long term sample stability
ensured
– No loss of analytes
TDU 2 Thermal Desorption
Thermal Extraction in µ-Vials
ATEX
Hot Injection & Trapping HIT
Stir Bar Sorptive Extraction
Twister Desorption
Dynamic Headspace
DHS
Automated Pyrolysis
PYRO
Stir Bar
Sorptive
Extraction
SBSE
Thermal
Desorption
(TDU/TDS)
Headspac
e Sorptive
Extraction
HSSE
Twister
Back
Extraction
(TBE)
LC
LC/MS
GC
GC/MS
Scientific Posters
Scientific Papers
MPS Integrated MAESTRO System Control
Sample Prep by mouse click
Prep Ahead
MPS Solution Enhanced Sample Preparation
Pesticides in Food by GC/QQQ
after QuEChERS clean-up
GC sample introduction
Automated GC inlet Liner
EXchange (ALEX)
GC sample introduction
MPS Solution
Enhanced Sample Preparation
Determination of flavor compounds
Dynamic Headspace
sampling
Thermal Desorption
using TDU 2
Olfactory detection of
odour active compounds
MPS Solution Enhanced Sample Preparation
Efficient Analysis of Fat content
in Food
Efficient mixing of a
two-phase system
Microwave accelerated
extraction / derivatization
GC sample introduction
MPS Workstation Enhanced Sample Preparation
Extraction of glycosides from
plant material (Metabolomics)
Sonication
Filtration using 17 μm
screen filters
Filtration using 0.45 μm
syringe filters
MPS Workstation Enhanced Sample Preparation
Lipid Fractionation from plant
material for LC/QTOF analysis
Liquid / liquid extraction
Evaporative
concentration
SPE Fractionation
Evaporative concentration
of SPE fractions
MPS Workstation Enhanced Sample Preparation
Your Application
Your Solution
Why do we want to turn our customers into winners ?
A winner will buy again and again …
… will promote GERSTEL technology
… will use GERSTEL instruments for publications
… could be used as reference customer
… will give input for new developments
Tenga un dia agradable e informativo!