Post on 16-Apr-2018
transcript
HeadingProduct Name
A Higher Level of Performance
Data Sheet
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
www.hawkmeasure.comFor more information, please visit >
2
Overview
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
•
Product overview
The Model HLT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass chamber) applications. The Model HLT transmitter provides a 4-20 mA output for most magnetic level gauge manufacturers and allows for mounting external to the chamber without interrupting the process.
Model HLT transmitters are modular in design offering a selection of mounting options and pipe styles. The modularity also offers simple field replacement. Subject to local electrical codes, the sensing element and electronics can be removed from the transmitter pipe without disturbing the operation of the process saving both time and money.
The model HLT transmitter uses HART communication for setup, calibration, and diagnostics. HART can be utilized via a hand-held communicator or with the HAWK setup software via a PC and HART to serial converter. The optional on-board display and keypad is also provided for local indication and programming.
• 4 to 20 mA Analog Output with HART®
• No Scheduled Maintenance or Recalibration
• High Accuracy and Repeatability
• AMS Aware
• Explosion-proof and/or Intrinsically Safe
Features
• Inventory Control
• Process Vessel
• Bypass Chamber
Applications
• Petroleum and Petrochemical
• Power Generation
• Specialty Chemical
Markets
Model HLT Transmitter with Analog Output and HART (CSA/FM, ATEX)
All specifications are subject to change. Contact HAWK for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only.
3
Overview
Product specifications
Level Plus® M-Series Model MRA3/4 Sightglass Transmitter - Analog OutputProduct Data Sheet, Part No.: 551252, Revision A 01-11 MTS Sensors
PRODUCT DATA SHEET
Parameters Speci�cations
LEVEL OUTPUT
Measured variable:
Product level
Output signal /Protocol: 4 to 20 mA with HART®
Order length: Rigid pipe: 508 mm (20 in.) to 3658 mm (144 in.) § ∆∆ Contact factory for longer lengths.§ Order length equals the measurement range plus the inactive zone.
Non-linearity: 0.02% F.S. or 0.794 mm (1/32 in.) *
* Whichever is greater
Repeatability: 0.01% F.S. or 0.381 mm (0.015 in.) *(any direction) † Contact factory for alternative materials.
COMPATIBILI TY
MRA3/4 chamber compatibility:
HAWKK-TekJergusonKencoWikaKlingerQuest-Tec
ELECTRONICS
Input voltage: 10.5 to 36.1 Vdc, 28 Vdc maximum for I.S. ATEX approval
Fail safe: High (21.4 mA), or Low (3.8 mA)
Reverse polarity protection: Series diode
Lightning/Transient protection:
Stage 1: Line-to-ground surge suppression; IEC 61000-4-5Stage 2: Line-to-line and line-to-ground transient suppressors; IEC 61000-4-4
CALIBRATION
Zero adjust range: Anywhere within the active length
Span adjust range: Full scale to 152 mm (6 in.) from zero
Parameters Speci�cations
ENVIRONMENTAL
Enclosure rating: NEMA Type 4X
Humidity: 0 to 100% relative humidity, non-condensing
Operating temperatures:
Electronics: -40 °C (-40 °F) to 71 °C (160 ºF)Sensing element: -40 °C (-40 °F) to 125 °C (257 °F) ◊
◊. Contact factory for speci�c temperature ranges.
FIELD INSTALLATION
Housing dimensions:
Single cavity:127 mm (5 in.) by 123 mm (4.85 in.) 121 mm (4.75 in.) O.D.
MOUNTING
Rigid pipe: Hose clamp to chamber
WIRING
Connections: 2-wire shielded cable twisted pair,
ELECTRICAL CONNECTIONS
Single Cavity: ¾ in. conduit opening, M20 for ATEX version
DISPLAY
Measured variables: Product level
Size: 13 mm (0.5 in.)
Number of digits: 16
Product speci�cations
Level Plus ® Model MRA3/4 Product Speci�cations
2
VizePenberthyOthers
Total Level or Interface Level
150Higher temperatures are available using a small insulation pad.
Dual Compartment Housings: 3/4 in. conduit opening, M20 for ATEX VersionSingle Cavity: 3/4 in. conduit opening, M20 for ATEX Version
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
4
Overview
Agency Approvals
Level Plus® M-Series Model MRA3/4 Sightglass Transmitter - Analog OutputProduct Data Sheet, Part No.: 551252, Revision A 01-11MTS Sensors
PrODuCt Data sHeet
agency approvals
Mts analog setup software
explosion proof Intrinsically safe
FM 3615C22.2 No. 30
Class I, Division 1, Groups B, C and D ••∆Class II, Division 1, Groups E, F and G ••Division 1, NEMA Type 4X
FM 3610C22.2 No. 157
Class I, Division 1, Groups A, B, C and DClass II, Division 1, Groups E, F and GClass III, T4Division 1, NEMA Type 4X
•• Explosion-proof housing required∆ 90° electronic mount is only for Groups C and D
eN 50020 PTB 00 ATEX 2069X
II 1/2 G bzw. II 2 GEEx ia IIB T4 bzw. EEx ia IIA T4
Level Plus® Model Mra3/4 agency approvals setup software and Programming
MTS has developed the MTS Setup Software to help customers program and customize their Level Plus Model MRA3/4 transmitter.
The Model MRA3/4 transmitter is programmed through the HART interface. This interface is easily connected to a PC by using the HART-to-Serial converter. The MTS Analog Setup Software allow the user to adjust both ‘Zero’ (4 mA) and ‘Span’ (20 mA) setpoints, adjust HART parameters, and customize the optional built-in display. MTS setup software is shipped with each transmitter order. However, if you require an additional copy or an upgrade to your previously installed setup software, software is available for download. Refer to the MTS Level Products page at http://www.mtssensors.com
Hart® handheld communicator programming
The Level Plus Model MRA3/4 transmitter programming can also be performed by using handheld HART communicator device such as the Rosemount® 375 or 475.
setpoint programming using the display
Any Level Plus Model MRA3/4 transmitter that is purchased with a display has the ability to adjust the 4 and 20 mA setpoints by pressing the appropriate button located at the bottom of the display.
3
HART ART® handheld communicator programming
The Model HLT transmitter programming can also be performed by using handheld HART communicator device such as the Rosemount® 375 or 475.
Setpoint programming using the display
Any Model HLT transmitter that is purchased with a display has the ability to adjust the 4 and 20 mA setpoints by pressing the appropriate button located at the bottom of the display.
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
5
Overview
Product dimensions and mounting
HAWK offers the Model HLT transmitter configured for external mounting to most Magnetic Level Gauges (MLG) (see ‘Figure 1’). The Model HLT can be ordered with the standard 5/8 inch OD pipe or the optional 1/2 inch OD pipe from 508 mm (20 in.) to 3658 mm (144 in.). Stainless steel hose clamps are typically used to secure the Model HLT to the MLG.
The Model HLT transmitter ‘Measuring Range’ is equal to the ‘Order Length’ minus the ‘Inactive Zone’. The ‘Measuring Range’ should equal the measuring range of the MLG. Ensure that there are no obstructions that will limit the ability to mount the Model HLT on the MLG.
Inactive Zone76.2 mm (3 in.)
Inactive Zone95.3 mm (3.75 in.)
Orderlength
MeasuringRange
132 mm(5.19 in.)
203.2 mm(8 in.)
Current Pulse Start pulse Magnetic
Float Assembly
Sensor Wire
Figure 1
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
6
Overview
Product dimensions and mounting
HAWK offers the Model HLT transmitter configured for external mounting to most Magnetic Level Gauges (MLG) (see ‘Figure 2’). The Model HLT can be ordered with the standard 5/8 inch OD pipe or the optional 1/2 inch OD pipe from 508 mm (20 in.) to 3658 mm (144 in.). Stainless steel hose clamps are typically used to secure the Model HLT to the MLG.
The Model HLT offers an optional 90 degree fitting for an MLG with both top and bottom flanges. The 90 degree fitting allows the electronic head of the Model HLT to be positioned to the side of the pipe allowing for simpler mounting.
The Model HLT transmitter ‘Measuring Range’ is equal to the ‘Order Length’ minus the ‘Inactive Zone’. The ‘Measuring Range’ should equal the measuring range of the MLG. Ensure that there are no obstructions that will limit the ability to mount the Model HLT on the MLG.
Level Plus® M-Series Model MRA3/4 Sightglass Transmitter - Analog OutputProduct Data Sheet, Part No.: 551252, Revision A 01-11MTS Sensors
PrODuCt Data sHeet
5
Level Plus® Model Mra3/4typical Installation and Mounting
Product dimensions and mountingMTS offers the Level Plus Model MRA3/4 transmitter configured for external mounting to most Magnetic Level Gauges (MLG) (see 'Figure 2'). The Model MRA3/4 can be ordered with the standard 5/8 inch OD pipe or the optional 1/2 inch OD pipe from 508 mm (20 in.) to 3658 mm (144 in.). Stainless steel hose clamps are typically used to secure the Model MRA3/4 to the MLG.
The Model MRA3/4 offers an optional 90 degree fitting for an MLG with both top and bottom flanges. The 90 degree fitting allows the electronic head of the Model MRA3/4 to be positioned to the side of the pipe allowing for simpler mounting.
The Model MRA3/4 transmitter ‘Measuring Range’ is equal to the ‘Order Length’ minus the ‘Inactive Zone’. The ‘Measuring Range’ should equal the measuring range of the MLG. Ensure that there are no obstructions that will limit the ability to mount the Model MRA3/4 on the MLG.
2ft.
9
6
3
1ft
9
6
3
0
Figure 2. Model MRA3/4 mounting, top and bottom flangeFigure 2
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
7
Overview
Ordering information for FM-CSA approvals
Level Plus® M-Series Model MRA3/4 Sightglass Transmitter - Analog OutputProduct Data Sheet, Part No.: 551252, Revision A 01-11 MTS Sensors
PrODuCt Data sHeet
6
Model Mra3/4 Liquid-Level transmitterOrdering information - FM and Csa approvals
Ordering information for FM-Csa approvals
traNsMItter MODeL = M 1
M = Magnetostrictive transmittertyPe = r 2
r = Analog output liquid-level transmitterINPut POWer = a 3
a = 24 Vdc, 2-wire loop
OutPut =4
3 = 4-20 mA Single loop with Display 4 = 4-20 mA Single loop no display
HOusING tyPe =5
B = Single cavity (explosion-proof and intrinsically safe) D = Single cavity with display (explosion-proof and intrinsically safe)
eLeCtrONICs MOuNtING =6
1 = Integral electronics 5 = 90° fitting, housing bottom left
3 = 90° fitting, housing top left 6 = 90° fitting, housing bottom right
4 = 90° fitting, housing top right
traNsMItter PIPe =7
B = Industrial pipe, 5/8 in. OD r = Industrial pipe, ½ in. OD
MaterIaLs OF CONstruCtION (WetteD Parts) =8
Note: contact factory for other materials
1 = 316L stainless steel
PrOCess CONNeCtION tyPe =9
X = Sightglass
PrOCess CONNeCtION sIZe =10
X = Sightglass
teMPerature =11
0 = None
uNIt OF MeasureMeNt =12
M = Metric (millimeters) Encode length in millimeters if using metric (XXXXX mm)
u = US Customary (inches) Encode length in inches if ordering in US Customary (XXX.XX in.)
LeNGtH = 13-17
= Order length based on unit of measurement
Rigid/Sanitary transmitter: 508 mm (20 in.) to 3658 mm (144 in.)
sPeCIaL =18
s = Standard product e = Engineering special (not affecting agency controlled parts or features)
D = Single cavity with display (explosion-proof and intrinsically safe)E = Dual cavity with display (explosion-proof and intrinsically safe)
, with HART , with HART
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
8
Overview
Ordering information for ATEX approval
Level Plus® M-Series Model MRA3/4 Sightglass Transmitter - Analog OutputProduct Data Sheet, Part No.: 551252, Revision A 01-11MTS Sensors
PrODuCt Data sHeet
traNsMItter MODeL = M 1
M = Magnetostrictive transmitter
tyPe = r 2
r = Analog output level transmitter
INPut POWer = a 3
a = 24 Vdc
OutPut =4
3 = 4-20 mA Single loop with display 4 = 4-20 mA singlel loop no display
HOusING tyPe =5
G = SIngle cavity (ATEX IIA) r = SIngle cavity (ATEX IIB)
J = Single cavity with display (ATEX IIA) t = Single cavity with display (ATEX IIB)
eLeCtrONICs MOuNtING =6
1 = Integral electronics
traNsMItter PIPe/HOse =7
B = Industrial pipe 5/8 in. OD r = Industrial pipe, ½ in. OD
MaterIaLs OF CONstruCtION (WetteD Parts) (Note: contact factory for other materials) =8
1 = Stainless steel, 1.4404
PrOCess CONNeCtION tyPe =9
X = Sightglass
PrOCess CONNeCtION sIZe =10
X = Sightglass
teMPerature =11
0 = None
uNIt OF MeasureMeNt =12
M = Metric (millimeters) Encode length in millimeters if using metric (XXXXX mm)
u = US Customary (inches) Encode length in inches if ordering in US Customary (XXX.XX in.)
LeNGtH (Order length based on unit of measurement) = 13-17
= Rigid or Sanitary transmitter: 508 mm (20 in.) to 3658 mm (144 in.)
sPeCIaL =18
s = Standard product e = Engineering special (not affecting agency controlled parts or features)
7
Model Mra3/4 Liquid-Level transmitterOrdering information - ateX approval
Ordering information for ateX approval
R = Single cavity (ATEX IIB)T = Single cavity with display (ATEX IIB)E = Dual cavity with display (explosion-proof and intrinsically safe)
, with HART , with HART
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
9
Overview
Programming and hardware accessories
Mts systems Corporationsensors Division
3001 Sheldon DriveCary, North Carolina27513, USATel.: +1-800-633-7609Fax: +1-919-677-2343 +1-800-498-4442e-mail: sensorsinfo@mts.comhttp://www.mtssensors.com
Mts sensor technologieGmbH & Co. KG
Auf dem Schüffel 9D - 58513 Lüdenscheid, GermanyTel.: +49-2351-9587-0Fax: +49-2351-56491e-mail: info@mtssensor.dehttp://www.mtssensor.de
Mts sensors technologyCorporation
737 Aihara-cho, Machida-shiTokyo 194-0211, JapanTel.: +81-42-775-3838Fax: +81-42-775-5516e-mail: info@mtssensor.co.jphttp://www.mtssensor.co.jp
seNsOrs
®
MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation.All other trademarks are the property of their respective owners.
All Temposonics sensors are covered by US patent number 5,545,984. Additional patents are pending.Printed in USA. Copyright © 2011 MTS Systems Corporation. All Rights Reserved in all media.
Part Number: 551252 revision a 01-11
FMAPPROVED
Level Plus® Model Mra3/4 accessoriesProgramming and Hardware
Programming and hardware accessoriesPrOGraMMING aCCessOrIes Part NuMBer
M-series Model Mra3/4PC setup software on CDIncludes HART adapter, part no. 380068
252273-1
M-series Model Mra3/4PC setup software on CD 252273-2
HarDWare Part NuMBer
Hart to rs-232 adapter(SMAR H1-311) 380068
HARDWARE PART NUMBER
MtS Systems CorporationSensors Division
3001 Sheldon DriveCary, North Carolina27513, USATel.: +1-800-633-7609Fax: +1-919-677-2343 +1-800-498-4442e-mail: sensorsinfo@mts.comhttp://www.mtssensors.com
MtS Sensor technologieGmbH & Co. KG
Auf dem Schüffel 9D - 58513 Lüdenscheid, GermanyTel.: +49-2351-9587-0Fax: +49-2351-56491e-mail: info@mtssensor.dehttp://www.mtssensor.de
MtS Sensors technologyCorporation
737 Aihara-cho, Machida-shiTokyo 194-0211, JapanTel.: +81-42-775-3838Fax: +81-42-775-5516e-mail: info@mtssensor.co.jphttp://www.mtssensor.co.jp
SENSORS
®
MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their respective owners. Printed in USA. Copyright © 2011 MTS Systems Corporation. All Rights Reserved in all media.
All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Go to http://www.mtssensors.com for the latest support documentation and related media.
Part Number: 550677 Revision J 01-11, 02-11
FMAPPROVED
HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)
10
HAWK, Since 1988
Hawk Measurement Systems Pty Ltd (HAWK) was established in 1988. It's founding members saw the universal requirement of various industries requiring improved process control and efficiency in their operations.
We Can Help
HAWK understands the difficulties customers face when seeking accurate level measurement. Every application is different, involving a multitude of environmental factors. This is where HAWK excels. Our aim is to ensure that customers not only feel comfortable with our technology, but that we also to ensure a consistent and reliable solution is in place for the long term. We believe that a combination of application and product expertise, as well as forward thinking and proactive support policies are the foundation of successful customer-supplier relationships.
11
Overview
Progressive Technical Support
HAWK believes that the future of the Level Measurement Industry revolves around the quality of pre and post sales - support. Our aim is for all sales & support staff to be product experts, and more importantly application experts making our customers applications as efficient and consistent as possible.
Remote Innovation
HAWK understands the need for immediate technical assistance.
The HAWKLink 3G communication device allows any computer with internet access and our free GosHawK diagnostic & calibration software; to dial in, calibrate, test, and check the performance of HAWK products. This innovative system allows our Global Support Team to assist with commissioning and after sales service of HAWK equipment worldwide. Measurement problems are addressed as they happen; not days or weeks later.
Knowledge Sharing
HAWK believes that knowledge sharing is key to creating long term relationships. Empowering our customers and our worldwide distribution network, whilst being available at all times to lend a helping hand, is the perfect recipe for long term solutions and relationships. HAWK openly extends an invitation to share our 25 years of level measurement experience, and ensure that your day to day processes are efficient, understood, and always working.
Hawk Measurement Systems(Head Office)15 - 17 Maurice Court Nunawading VIC 3131, AUSTRALIA
Phone: +61 3 9873 4750Fax: +61 3 9873 4538info@hawk.com.au
Hawk Measurement 7 River StreetMiddleton, MA 01949, USA
Phone: +1 888 HAWKLEVEL (1-888-429-5538)Phone: +1 978 304 3000Fax: +1 978 304 1462info@hawkmeasure.com
Represented by:
For more information and global representatives: www.hawkmeasure.com
Additional product warranty and application guarantees upon request. Technical data subject to change without notice.
A Higher Level of Performance