Post on 08-Apr-2016
description
transcript
Application
Index
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 1
The following is a list of the application details in this section. The drawings areavailable as CAD downloads from the Hepworth web site at:www.hepworthdrainage.co.uk – under the Technical dropdown heading click onCAD Downloads for a view of the full set of drawings.
1 - DC1 – Direct connection to internal waste/rainwater pipe page 2
2 - DC2 – Direct connection to soil and vent pipes page 3
3 - DC3 – Telescopic rest bend connection page 4
4 - DCA – External rainwater pipe – connection detail page 5
5 - GC1 – Inlet gully – connection detail page 6
6 - GC2 – Access gully – connection detail page 7
7 - GC3 – Square P gully – connection detail page 8
8 - GC4 – Vertical inlet hopper – trapped connection detail page 9
9 - GC4P – Vertical inlet hopper – trapped connection detail page 10
10 - GC5 – Horizontal inlet hopper – trapped connection detail page 11
11 - GC6 – Paved area gully – connection detail page 12
12 - GC8 – Yard gully – connection detail page 13
13 - GC9 – Road gully – connection detail page 14
14 - AP1 – Rodding point – installation detail page 15
15 - GEN3 – Mini access chamber positioned off main drain run page 16
16 - AP2 – Polypropylene inspection chamber page 17
17 - AP3 – Polypropylene inspection chamber page 17
18 - AP6 – Reduced Access Telescopic PPIC page 18
19 - GEN1 – Mini access chamber – installation detail page 19
20 - GEN2 – Backdrop connection to manhole – application detail page 20
21 - AP5 – Grease trap – installation detail page 21
22 - TD – Threshold drain – installation detail page 22
HepSure® – Application schedule pages 23 to 24
Application
Direct connection to internal waste/rainwater pipe
Section 10 Page 2 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
1 - DC1 SuperSleve and PlastiDrain
SuperSleve
Waste orrainwaterpipe
Alternative detail using internaladaptor retro-fitted in pipe,finished flush with screed(waste pipe only).
Maximum 600mm long“Rocker” pipe
Waste pipeadaptor codes:
• SA4
• SA5
• SA6
• 4A03A
• 4A04A
• 4A05A
• 4P03A
90º bend codes:
• SDB1/1S
Short lengthof pipe cut tosuit
Coupling within 150mmof structure codes:
• SC1/1 • 4P02A
Internal Adaptor to waste codes:
• S/S460
• S/S462
• S460P
• S462P
Rainwater pipe adaptor codes:
• SA7
• SA8
• 4A06A
• 4A07A
PlastiDrain
Application
Direct connection to soil and vent pipes
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 3
Soil pipe
Maximum 600mm long“Rocker” pipe
Soil pipe adaptorcodes:
• SA9
Rest bend codes:
• SDBR1
Short lengthof pipe cut tosuit
Coupling within 150mm ofstructure codes:
• SC1/1 • 4P07F
• 4P02A
2 – DC2 SuperSleve and PlastiDrain
SuperSleve
PlastiDrain
Application
Telescopic rest bend connection
Section 10 Page 4 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
Soil or waste adaptor
Short length of pipe laid tosteep gradients ensuringacceptable falls aftersettlement has occurred
Suspendedfloor slab
Up to 180mmtelescopic movementwhere heave isexpected insert pipe tohalf socket depth
Possible void Telescopic rest bend code:
• SBRT1
3 – DC3 SuperSleve
SuperSleve
Application
External rainwater pipe – Connection detail
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 5
Rainwater pipe
Internal Adaptor to rainwaterpipe codes:
• S/4A06B
• S/4A06C
• 4A06R
• 4A06S
Short lengthof pipe cut tosuit
90º bend codes:
• SDB1/1S • 4P03A
4 – DC4 SuperSleve and PlastiDrain
SuperSleve
PlastiDrain
Application
Inlet Gully – Connection detail
Section 10 Page 6 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
Waste or rainwater pipe upto maximum 68mm diameter,inserted through brush strip
Inlet Gully codes:
• SDG3/1 • 4A17A
Remove Dip Tube Trap forfull bore rodding
Concrete bed
5 – GC1 SuperSleve and PlastiDrain
SuperSleve
PlastiDrain
Note:
A cut length of 150mm SuperSleve pipe and a150mm Coupling inserted between the hopperand the base can be used to increase the gullydepth to a maximum of 600mm
For PlastiDrain there is a specific product for this,the code is 4A17E.
Application
Access Gully – Connection detail
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 7
Waste or rainwater pipe up tomaximum 110mm diameter or100mm square
Access Gully codes:
• SG3/1
Bent to suit Cement mortar filletConcrete bed
6 – GC2 SuperSleve
SuperSleve
Polypropylene grid provided.
Sealing plate, code IS1
Plain metal grid, codes IG1 (alloy) or IG1C(cast iron)
Hinged metal grid, code IH1 (alloy)
Application
Square P Gully – Connection detail
Section 10 Page 8 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
Waste or rainwater pipe up to maximum 68mm diameteror 65mm square
Square Gully codes:
• SG2/1 • 4A12A
Removable stopperallowing roddingaccess
Concrete bedBend to suit
7 – GC3 SuperSleve and PlastiDrain
SuperSleve
PlastiDrain68mm diameterrainwater pipe
32/40mm wastepipe
Double waste pipe
65mm squarerainwater pipe
Polypropylene grid provided.
Standard 150mm metal grid can be used inplace of grid supplied.
Alloy plain, code IG2
Cast iron plain, code IG2C
Alloy hinged, code IH2
Cast iron hinged, code IH2C
Application
Vertical Inlet Hopper – Trapped connection detail
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 9
8 – GC4 SuperSleve
SuperSleve
Waste or rainwater pipe up to maximum110mm diameter or 100mm square
Polypropylene grid provided.
Sealing plate, code IS1
Plain metal grid, codes IG1 (alloy) orIG1C (cast iron)
Hinged metal grid, code IH1 (alloy)
Vertical Inlet Hopper code:
• SH3/1
P-Trap code:
• SDG1/1
Concrete bed
Application
Vertical Inlet Hopper – Trapped connection detail
Section 10 Page 10 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
9 – GC4-P PlastiDrain
PlastiDrain
Waste or rainwater pipe up to maximum90mm diameter or 90mm square
Plastic grid (provided)
Vertical Inlet Hopper code:
• 4H11A
P-Trap code:
• 4T10C
Application
Horizontal Inlet Hopper – Trapped connection detail
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 11
10 – GC5 SuperSleve
SuperSleveWaste or rainwaterpipe
Waste pipe adaptor codes:
32mm SA4
40mm SA5
50mm SA6
RWP adaptor codes:
82mm SA8
110mm SA9
Alternative detail using internaladaptor retro-fitted in pipe, finishedflush with screed (waste pipe only).
Internal Adaptorto waste codes:
32/40mm S/S46050mm S/S462
Short length ofpipe cut to suit
90º bend code:SDB1/1S
Hopper code: SH2
Plain loose grid, 150mm square codes:Alloy IG2Cast iron IG2C
Hinged grid mortared in, 150mm square codes:Alloy IH2Cast iron IH2C
P-Trap code: SDG1/1
Application
Paved Area Gully – Connection detail
Section 10 Page 12 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
Paved area Gully codes:
• SDG2/1 • 4A22A
Bend to suit Remove Dip Tube Trapfor full bore rodding
Concrete bed
11 – GC6 SuperSleve and PlastiDrain
SuperSleve
PlastiDrain
Note:
A cut length of 150mm SuperSleve pipe and a 150mmCoupling inserted between the hopper and the base canbe used to increase the gully depth to a maximum of600mm.
For PlastiDrain there is a specific product for this, the codeis 4A17E.
Application
Yard Gully – Connection detail
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 13
Yard Gully codes with light duty (1 tonne) grid:
100mm outlet RGP5110mm outlet 4A30A and 4A31A150mm outlet RGP7
Yard Gully codes with medium duty (5 tonnes) grid:
100mm outlet RGP6110mm outlet 4A30A and 4A32A150mm outlet RGP8
Bend to suit Filter/Silt bucket code: • IBP3
• 4A33A
Concrete bed
12 – GC8 SuperSleve and PlastiDrain
SuperSleve
Note:
The depth of the gully can be increased by up to 300mmby fitting a 225mm coupling code VC1/3S and a 300mm high raising piece code SIC3/1 or 4A34Abetween the frame and the gully body.
PlastiDrain
Application
Road Gully – Connection detail
Section 10 Page 14 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
Grating to suit wheel load – eg Grade C250, codes IDG1, IDG8
or Grade D400, codes IDG7, IDG9
to BS EN124:1994
Bend to suit Engineering brickwork, depth tosuit specification
Trapped road gully codes:
300 x 600 x 100 RGR1
300 x 600 x 150 RGR2
400 x 750 x 150 RGR3
450 x 900 x 150 RGR4
375 x 750 x 150 MGP2/2
510 x 840 x 150 MGP3/2
Untrapped road gully codes:
375 x 750 x 150 MGP2/1
510 x 840 x 150 MGP3/1
Concrete bed andsurround
13 – GC9 Road Gully
Clay road gully
Polyethylene road gully
Note:
Gully outlet and connection may require concreteprotection where cover is minimal.
Application
Rodding Point – Installation detail
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 15
Square rodding point codes:
• SRPS1/1 • 4A10SA
Concrete bed Short length of pipecut to suit
Bend to suit
14 – AP1 SuperSleve and PlastiDrain
SuperSleve
PlastiDrain
Application
Mini Access Chamber positioned off main drain run
Section 10 Page 16 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
Soil pipe adaptor codes:
• SA9
Soil pipe
Short length ofpipe cut to suit
Bend to suitdepth of maindrain (max 45º)
Mini accesschamber code:
• SDAC1/1
Coupling within 150mmof structure codes:
• SC1/1
45º bend codes:
• SDB2/1S
45º junction onmain drain run
15 – GEN3 SuperSleve and PlastiDrainApplication Detail
SuperSleve
PlastiDrain
Rest bend codes:
• SDBR1 • 4P02A
• 4P04A• 4P07F
Application
Polypropylene Inspection Chamber
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 17
Square recessed coverand frame filled withmatching material code:
SPCR8
225mm deep concreteplinth to support finish
17 – AP3 SuperSleve and PlastiDrainInstallation Detail
Sited in driveways/hard landscaped areas, with recessed cover
Sited in concrete floor slab
Sited in driveways/hard landscaped areas, with standard round cover
Sited in soft landscaped areas, with standard round cover
Square airtight cover andframe code:
SPKS8
16 – AP2 SuperSleve and PlastiDrainInstallation Detail
Mini Access Chamber code: SDAC1/1
max 600mm deep
150mm concreteplinth to support finish
Well compactedbedding materialused as backfill
Mini Access Chamber code: SDAC1/1
max 600mm deep
Topsoil
Well compactedbedding materialused as backfill
Application
Reduced Access Telescopic PPIC
Section 10 Page 18 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
225mm deepconcrete collar
Telescopicraising piece
18 – AP6 SuperSleve and PlastiDrainInstallation Detail
Sited in driveways/hard landscaped areas Maximum depth 3.0m
Topsoil
Telescopicraising piececode SPIC3/7
Raising piece700mm: code SPIC3/4,175mm: code SPIC4
Sealing ringcode SPIC5
Compactedbackfill
Excavationwidth variesdepending ondepth
PPIC
Sited in soft landscaped areas Maximum depth 3.0m
350mm telescopicmovement
4º angulardeflection
Application
Mini Access Chamber & PPIC – Installation detail
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 19
Notes:
• Where chambers are positioned on 90º corners always use the main channel by fitting a 45º bend on inlet and outlet
• Bends up to max 45º angle can be used on any inlet
• Heaviest flow should always be directed through main channel
• Short steep connections should preferably be connected via a 45º inlet using a bend where necessary
Inlet adaptor, code SPIC7
100mmcoupling
code: SC1/1
Mainflow
Main flow
Mini access chamber
code: SDAC1/1
19 – GEN1 SuperSleve and PlastiDrain
PPIC – 100mm inlet
940mm deep, code: SPIC1/1
595mm deep, code: SPIC2/1
PPIC 150mm inlet – code: SPIC1/2
Main flow
Mainflow
Mainflow
Mainflow
Mainflow
Main flow
Application
Backdrop connection to manhole – Application detail
Section 10 Page 20 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
Lever locking Stopperattached to manhole wall withchain and staple, code:
• IL1 (100mm)• IL2 (150mm)
Socket adaptor cutto suit, code:
• SA1/1 (100mm)• SA1/2 (150mm)
Pipes cut to suit
Half channel
20 – GEN2 SuperSleve and PlastiDrain
SuperSleve
PlastiDrain
Rest bend codes: • SDBR1 (100mm)• SBR2 (150mm)
Curved square junction codes:
• SDJ2/1D (100mm)• SJ2/3 (150mm)
Note: Backdrops formed in PlastiDrain pipeworkare usually constructed inside the manhole.
Application
Grease Trap – Installation detail
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 21
Cover and frameEngineering brickwork to suitdepth of cover required
Filter basket and spatula fitted and inlet 150mm concrete bed and surround
Note:
The grease trap does not form an air trappreventing sewer gases from movingupstream. Appliances connected should beindividually trapped.
SuperSleve
21 – AP5SuperSleve andPlastiDrain
PlastiDrain
Application
Threshold Drain – Installation details
Section 10 Page 22 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
• Removable grid
• Drained to ground (eg in freedraining soils) Threshold drainchannel with end caps fitted withsnap-out section removed
• Connected to drain (eg inexposed location) Threshold drainchannel with end caps fitted
• Outlet adaptor fitted over holemade in channel base
• Drainage adaptor, codes: • SA5• 4A04A
• Drainage bend to suit
22 – TD SuperSleve and PlastiDrain
TD2 – Beam and block floor
TD4 – Suspended timber floor
TD6 – Retro-fit
• Removable grid
• Drained to ground (eg in freedraining soils) Threshold drainchannel with end caps fitted withsnap-out section removed
• Connected to drain (eg inexposed location) Threshold drainchannel with end caps fitted
• Outlet adaptor fitted over holemade in channel base
• Drainage adaptor, codes: • SA5• 4A04A
• Drainage bend to suit
• Removable grid
• Drained to ground (eg in freedraining soils) Threshold drainchannel with end caps fitted withsnap-out section removed
• Cement mortar fillet supportingintegral DPM trimmed to suit
• Connected to drain (eg inexposed location) Thresholddrain channel with end caps fitted
• Outlet adaptor fitted over holemade in channel base
• Drainage adaptor, codes: • SA5• 4A04A
S S
S S
S S
P D
P D
P D
Application
HepSure® - Application schedule
Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk Section 10 Page 23
MRC4
QSC275
QSC265
160mm PVC-U150mm Ductile Iron150mm Cast Iron (BS416)150mm Cast Iron (BS437)150mm Stainless Steel150mm UltraRib150mm Quantum
100mm (4") Salt Glazed Ware100mm Vitrified Clay100mm SuperSleve100mm Pitch Fibre100mm Asbestos Cement
225mm (9") Salt Glazed Ware225mm Vitrified Clay225mm Concrete (O.D. up to 290mm)250mm Asbestos Cement250mm Ductile Iron
375mm (15") Salt Glazed Ware375mm Vitrified Clay375mm Concrete (O.D. up to 465mm)400mm Asbestos Cement450mm PVC-U
225mm Asbestos Cement225mm Ductile Iron250mm Cast Iron225mm SuperSleve
300mm (12") Salt Glazed Ware300mm Vitrified Clay300mm Concrete (O.D. up to 385mm)300mm SuperSleve
375mm Asbestos Cement400mm Ductile Iron400mm Cast Iron
375mm Concrete (O.D. over 456mm up to 490mm)450mm Ductile Iron450mm Asbestos Cement
225mm Concrete (O.D. over 290mm)
315mm PVC-U
300mm Concrete (O.D. over 405mm)
375mm Concrete (O.D. over 510mm up to 525mm)
450mm Concrete (O.D. over 560mm up to 580mm)
450mm Concrete (O.D. over 580mm up to 600mm)
110mm PVC-U100mm Ductile Iron100mm Cast Iron (BS416)100mm Cast Iron (BS437)100mm Stainless Steel100mm SuperSleve (see also MRC1)
175mm Pitch Fibre200mm Vitrified Clay200mm Asbestos Cement225mm UltraRib225mm Quantum250mm PVC-U
QSC175
MRC1
MRC3
QSC465
QSC445
QSC490
QSC310
QSC320
QSC425
QSC525
QSC580QSC600
MRC2
QSC120
QSC250
150mm (6") Salt Glazed Ware150mm Vitrified Clay150mm SuperSleve150mm Pitch Fibre150mm Asbestos Cement150mm Concrete180mm UltraRib200mm PVC-U
QSC165
QSC345
MRC6
QSC225
QSC335
QSC410
QSC430
MRC5
160mm PVC-U150mm Cast Iron (SMU/Ensign/SML)150mm Stainless Steel160mm Polyethylene
300mm Asbestos Cement300mm UltraRib300mm Quantum300mm Ductile Iron
450mm (18") Salt Glazed Ware450mm Vitrified Clay450mm Concrete (O.D. up to 560mm)500mm Asbestos Cement
200mm Ductile Iron200mm Cast Iron (BS416)
250mm Ductile Iron250mm Cast Iron225mm SuperSleve
300mm Ductile Iron300mm Cast Iron
300mm Concrete (O.D. over 385mm)400mm PVC-U
400mm Ductile Iron375mm Asbestos Cement
375mm Concrete (O.D. over 490mm up to 510mm)400mm Vitrified Clay
110mm PVC-U100mm Cast Iron (Soil) (SMU/Ensign/SML)100mm Stainless Steel100mm Corrugated Plastic110mm Corrugated Plastic
50mm (2") Polypropylene50mm (2") ABS50mm (2") Cast Iron (Soil)
100mm (4") Salt Glazed Ware100mm Vitrified Clay100mm SuperSleve100mm Pitch Fibre100mm Asbestos Cement
150mm SuperSleve150mm Pitch Fibre150mm Asbestos Cement150mm Twin Walled Plastic (B&H/Uniflex/Aquapipe)150mm Corrugated Plastic (B&H)
QFDC115
QFDC65
QFDC135
QFDC185
QFDC95
QFDC165
QFDC175
QFDC195
QFDC150
82mm (3") PVC-U75mm Cast Iron (Soil & Drain) (SMU)75mm Ductile Iron75mm Grey Iron
160mm PVC-U150mm Cast Iron (SMU/Ensign/SML)150mm Stainless Steel160mm Polyethylene
125mm Cast Iron (Soil)125mm Twin Walled Plastic
100mm SuperSleve100mm Cast Iron (Drain)100mm Ductile Iron100mm Grey Iron100mm Asbestos Cement100mm Pitch Fibre100mm Twin Walled Plastic
QFDC125
150mm SuperSleve150mm (6") Salt Glazed Ware150mm Vitrified Clay150mm Concrete150mm Asbestos Cement150mm Pitch Fibre
160mm PVC-U150mm Ductile Iron150mm Cast Iron (BS416)150mm Cast Iron (BS437)150mm Stainless Steel150mm UltraRib150mm Quantum
Standard Couplings Drain Couplings
For product details see pages 9-12 in Section 9.
A complete HepSure® brochure is available to download from our website,
along with a product selector which enables you to determine the correct
product by simply selecting the two pipes to be connected.
Application
HepSure® - Application schedule
Section 10 Page 24 Technical Advisory Service Tel: 0844 856 5165 Fax: 0844 856 5166 E-mail: technical.design@wavin.co.uk
QAC5144
QAC1361
QAC1362
QAC1002
QAC1001
QAC1221
QAC2908
QAC1602
QAC1922
QAC1923
QAC1924
PVC-U 110mmDuctile Iron 100mm
Cast Iron (Soil & Drain) 100mmCast Iron (SMU/Ensign/SML) 100mm
Stainless Steel 100mmSuperSleve 100mm
Asbestos Cement 100mm
100mm Cast Iron (Soil)100mm Cast Iron (SMU/Ensign/SML)100mm Stainless Steel110mm PVC-U
100mm Cast Iron (Soil)100mm Cast Iron (SMU/Ensign/SML)100mm Stainless Steel110mm PVC-U
50mm (2") Polypropylene50mm (2") ABS50mm (2") Cast Iron (Soil)
160mm PVC-U150mm Cast Iron (SMU/Ensign/SML)150mm Stainless Steel
40-50mm PVC-U40-50mm Polypropylene40-50mm ABS
PVC-U 110mmCast Iron (Soil & Drain) 100mm
Cast Iron (SMU/Ensign/SML) 100mmDuctile Iron 100mmSuperSleve 100mm
Salt Glazed Ware (9") 225mmVitrified Clay 225mmDuctile Iron 250mm
Grey Iron 250mmMDPE 280mm
PVC-U 160mmCast Iron (SMU/Ensign/SML) 150mm
Stainless Steel 150mm
Vitrified Clay (S.G.W.) 150mmSuperSleve 150mm
UltraRib 150mmDuctile Iron 150mm
Cast Iron (Drain) 150mmAsbestos Cement 150mm
Pitch Fibre 150mmTwin Walled Plastic 150mm
Vitrified Clay (S.G.W.) 150mmSuperSleve 150mm
UltraRib 150mmDuctile Iron 150mm
Cast Iron (Drain) 150mmAsbestos Cement 150mm
Pitch Fibre 150mmTwin Walled Plastic 150mm
Vitrified Clay (S.G.W.) 150mmSuperSleve 150mm
UltraRib 150mmDuctile Iron 150mm
Cast Iron (Drain) 150mmAsbestos Cement 150mm
Pitch Fibre 150mmTwin Walled Plastic 150mm
SuperSleve 100mmVitrified Clay 100mm
Asbestos Cement 100mmCast Iron (SMU/Ensign/SML) 125mm
82mm (3") PVC-U75mm Cast Iron (Soil & Drain)75mm Cast Iron (SMU/Ensign)75mm Ductile Iron70mm Cast Iron (SMU/Ensign/SML)
82mm (3") PVC-U75mm Cast Iron (Soil & Drain)75mm Cast Iron (SMU/Ensign)75mm Ductile Iron70mm Cast Iron (SMU/Ensign/SML)
SuperSleve 100mmVitrified Clay 100mm
Asbestos Cement 100mmCast Iron (SMU/Ensign/SML) 125mm
PVC-U 110mmCast Iron (Soil) 100mm
Cast Iron (SMU/Ensign/SML) 100mmStainless Steel 110mm
PVC-U 110mmCast Iron (Soil) 100mm
Cast Iron (SMU/Ensign/SML) 100mmStainless Steel 110mm
110mm PVC-U100mm Cast Iron (Soil & Drain)100mm Cast Iron (SMU/Ensign/SML)100mm Ductile Iron100mm Stainless Steel100mm SuperSleve
110mm PVC-U100mm Cast Iron (Soil & Drain)100mm Cast Iron (SMU/Ensign/SML)100mm Ductile Iron100mm Stainless Steel100mm SuperSleve
100mm SuperSleve10mm Vitrified Clay100mm Asbestos Cement125mm Cast Iron (SMU/Ensign/SML)
200mm Vitrified Clay225mm Asbestos Cement225mm UltraRib225mm Ductile Iron225mm Cast Iron (Drain)250mm PVC-U250mm MDPE
110mm PVC-U100mm Ductile Iron100mm Cast Iron (Soil & Drain)100mm Cast Iron (SMU/Ensign/SML)100mm Stainless Steel100mm SuperSleve
Salt Glazed Ware (6") 150mmVitrified Clay 150mm
Pitch Fibre 150mmAsbestos Cement 150mm
Concrete 150mmUltraRib 180mmPVC-U 200mm
QAC4000
QAC9001
Salt Glazed Ware (4") 100mmVitrified Clay 100mmSuperSleve 100mmPitch Fibre 100mm
Asbestos Cement 100mm
Salt Glazed Ware (9") 225mmVitrified Clay 225mmSuperSleve 225mmDuctile Iron 250mm
Grey Iron 250mmMDPE 280mm
160mm PVC-U150mm Ductile Iron150mm Cast Iron (Soil & Drain)150mm Cast Iron (SMU/Ensign/SML)150mm Stainless Steel150mm UltraRib
150mm Vitrified Clay150mm Pitch Fibre150mm Asbestos Cement150mm Concrete180mm MDPE180mm UltraRib200mm PVC-U200mm MDPE
QAC6000
Drainage Adaptors Universal Adaptors
For product details see pages 9-12 in Section 9.
A complete HepSure® brochure is available to download from our website,
along with a product selector which enables you to determine the correct