HiperII/ GRX-1 Model Number and Serial Number Input Procedure

1. Open Ploader set up comport that is connected to unit

2. Click on the set up tab, type in the receiver model name and click apply

3. Unit will shut down and restart, once unit has restarted click “get from device” and the

receiver name should appear on the serial number box

4. Close Ploader

5. Connect to PCCDU

6. Go to file Manual Mode

7. In the Manual Mode put in the following script to get the receiver id number

%%print,/par/rcv/id

8. Hit send command and you should get the receiver id for the unit

9. Input the following script to set the units serial number

%%set,codedsn,(ID)SN(HiPerII/U)(SERIALNUMBER) – Need not input ( )

Hit send command

10. If the script goes through you will get a RE002% as a return on the screen disconnect

from the unit.

11. Connect to TRU and go to the information icon and you should see the model number

with the serial number in this screen.