Key features
•Optimizedfordatacenterswithextensivevirtualizationandconvergencefeatures
•Broadinterfaceoptionsfrom1Gto100Gscalingupto24.3Tb/sswitchingcapacity
•SDNreadywithOpenFlow1.3support
•LargeLayer2andLayer3tablestosupportlargescaledeployments
•Fullyredundantarchitecturewithhotswappablecomponents
Product overview
TheHPE12500SwitchSeriesisafamilyofpowerful,next-generationroutingswitcheswithoutstandingcapacityandscaleforthenetworkcoreordatacenter.
Designedforhighperformancewithnon-blockinganddistributedClosarchitecture,theseswitchesdeliverupto24.3Tb/sswitchingcapacityand10.8Bppsthroughputwithupto400Gb/sperlinecardslot.
The12500switchesalsohaveenergy-efficiencyfeaturesthatdrivedownoperationalexpensesandareidealfororganizationscontemplatinglarge-scaledatacenterconsolidations,businesscontinuityanddisasterrecoverysites,metropolitanareanetworkdeployments,andotherapplicationsrequiringarobust,reliable,andhighlyavailableswitchingplatform.
HPE 12500 Switch Series
Data sheet
Page 2Data sheet
Features and benefits
Data center optimized•ScalableLayer2fabrics
Buildflexible,resilient,andscalableLayer2fabricswithSPBandHPEIRF
•Multi-tenantDeviceContext(MDC)
Isaninnovativedatacentervirtualizationsolutionthatenablesmulti-tenancy,givingcustomerstheabilitytovirtualizeaphysicalswitchintomultiplelogicaldevices,witheachlogicalswitchhavingitsowntenants
•HPEEthernetVirtualInterconnect(EVI)
IsanHPEVirtualApplicationNetworkinnovationthatprovidesaLayer2extensionacrossthedatacentertosimplifytheinterconnectivityofgeographicallydispersedatacenters
•DataCenterBridging(DCB)protocols
ProvidesupportforIEEE802.1QazDataCenterBridgingExchange(DCBX),EnhancedTransmissionSelection(ETS),andIEEE802.1QbbPriorityFlowControl(PFC)forconvergedfabrics
•FibreChanneloverEthernet(FCoE)features
DeliversupportforFCoE,includingexpansion,fabric,trunkVFandNports,andaggregationofE-portandN-portvirtualization
•Acceleratedperformancewithjumboframes
Forintra-data-centercommunication,orfordatacentertodatacentertraffic(disasterrecovery),reducingtheamountoftimerequiredfordatabackupandrecovery
•Networkloadbalancing(NLB)multicastARP
Microsoft®NLBco-workswithmulticastARPtoprovideserverswithloadbalancingandfaultswitchover,whichlowerscostsandinvestment
Page 3Data sheet
Software-defined networking•SupportsOpenFlow1.3specifications
ToenableSDNbyallowingseparationofthedata(packetforwarding)andcontrol(routingdecision)paths
Performance•High-performancedesignwithnon-blockinganddistributedClosarchitecture
Deliversupto24.3Tb/sswitchingcapacityand10.8Bppsthroughputwithupto400Gb/sperlinecardslot
•High-density1/10/40/100GbEinterfaceconnectivity
Offersupto18interfacemoduleslotstoscaleupto8641GbEor1/10GbEor28840GbEor72100GbEports
•Hardware-basedwirespeedaccesscontrollists(ACLs)
Helpprovidehighlevelsofsecurityandeaseofadministrationwithoutimpactingnetworkperformancewithafeature-richTCAM-basedACLimplementation
•High-performanceprocessorsystem
Thesupervisormoduleusesthreedifferentprocessorstoisolatekeytasks:controlplane(STP,OSPF,BGP,MPLS,etc.),fastrecoveryprotocols(RRPP,BFD,etc.),andchassismanagement(temperature,power,etc.)
Product architecture•Distributedarchitecturewithseparationofdataandcontrolplanes
Deliversenhancedfaulttoleranceandfacilitatescontinuousoperationandzeroservicedisruptionduringplannedorunplannedcontrol-planeevents
•AdvancedComwaremodularOS
Bringsmodularity,enhancedserviceability,stability,andindependentprocessmonitoringthroughmodernComwarev7OperatingSystem
•In-ServiceSoftwareUpgrade(ISSU)
Providesanupgradeoftheentirechassis,oranindividualtaskorprocess,withzeropacketloss
Page 4Data sheet
Resiliency and high availability•IntelligentResilientFramework(IRF)
Createsvirtualresilientswitchingfabrics,wheretwoormoreswitchesperformasasingleL2switchandL3router;switchesdonothavetobeco-locatedandcanbepartofadisaster-recoverysystem;serversorswitchescanbeattachedusingstandardLACPforautomaticloadbalancingandhighavailability;caneliminatetheneedforcomplexprotocolslikeSpanningTreeProtocol(STP),Equal-CostMultipath(ECMP),orVRRP,therebysimplifyingnetworkoperation
•Ultrafastprotocolconvergence
EnableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforRIP,OSPF,BGP,IS-IS,VRRP,MPLS,andIRF
•DeviceLinkDetectionProtocol(DLDP)
Monitorslinkconnectivityandshutsdownportsatbothendsifunidirectionaltrafficisdetected,preventingloopsinSTP-basednetworks
•Completesetofroutingprotocols(Layer3IPv4andIPv6)
SupportingwiderangeofroutingprotocolsincludingRIP,OSPF,IS-IS,andBGPforbothIPv4andIPv6alongwithcompletesupportofPIM-DM,PIM-SM,PIM-SSM,andMSDP
•Hotpatching
The12500SwitchSeriessupportshotpatching,allowingin-servicepatchingforsomeisolatedsoftwareproblems
•NonstopForwarding/GracefulRestart(NSF/GR)
Usingstandardized-basedIETFprotocols,the12500SwitchSeriesprovidesnonstopforwarding(switching/routing)forLayer3routingprotocols(controlplane—OSPF,BGP,andMPLS),providinghitlessfailover
•Fullyredundantandhotswappablecomponents
Providingfullhardwareredundancyforeachcomponentincludingpowersupplies,fantrays,supervisormodules,andfabricmodulestoenablethehighestlevelofavailability
•RapidRingProtectionProtocol(RRPP)
ProvidesfastrecoveryforringEthernet-basedtopology
Page 5Data sheet
Quality of Service (QoS)•VirtualOutputQueue(VOQ)
Preventshead-of-line(HOL)blockingandgracefullyhandlesburstydatacentertrafficincreasingswitchperformance
•IEEE802.1pprioritization
Deliversdatatodevicesbasedonthepriorityandtypeoftraffic
•Layer4prioritization
EnablesprioritizationbasedonTCP/UDPportnumbers
•Broadcastcontrol
Allowslimitationofbroadcasttrafficratetocutdownonunwantednetworkbroadcasttraffic
•Advancedclassifier-basedQoS
ClassifiestrafficusingmultiplematchcriteriabasedonLayer2,3,and4information;appliesQoSpoliciessuchassettingprioritylevelandratelimittoselectedtrafficonaper-portorper-VLANbasis
•Bandwidthshaping
–Port-basedratelimiting
Providesper-portingress-/egress-enforcedmaximumbandwidth
–Classifier-basedratelimiting
UsesACLstoenforcemaximumbandwidthforingress/egresstrafficoneachport
Compartmentalization•Departmentprotection
Usingnetworkvirtualizationstandards(QinQ,VRF,andMPLS),the12500SwitchSeriesallowsorganizationstoisolatedifferentbusinessunitswithdifferentresources(VRFs);usingstandard-basedmechanisms,thenetworkiscompletelyvirtualized,reducingcostandoperations
•IEEE802.1ahProviderBackboneBridge(MACinMAC)
ProviderBackboneBridge(PBB)isaLayer2VPNtechnologythatallowsacompleteseparationofcustomerandproviderdomainsbysealingtheuserMACintheserviceproviderMAC,whichenhancesthescalabilityofanEthernetnetwork
Page 6Data sheet
Layer 2 switching•MultipleVLANRegistrationProtocol(MVRP)
HelpstomaintainVLANconfigurationdynamicallybasedoncurrentnetworkconfigurations
•GARPVLANRegistrationProtocol
AllowsautomaticlearninganddynamicassignmentofVLANs
•IPmulticastsnoopinganddata-drivenIGMP
AutomaticallypreventsfloodingofIPmulticasttraffic
•IEEE802.1adQinQ
IncreasesthescalabilityofanEthernetnetworkbyprovidingahierarchicalstructure;connectsmultipleLANsonahigh-speedcampusormetronetwork
•BridgeProtocolDataUnit(BPDU)tunneling
TransmitsSTPBPDUstransparently,allowingcorrecttreecalculationsacrossserviceproviders,WANs,orMANs
•VLANsupportandtagging
SupportsIEEE802.1Q(4KVLANIDs)
•SpanningTree
The12500SwitchSeriessupportstheentiresetofSTPprotocols(STP,RSTP,andMSTP),facilitatingacompleteintegrationwithstandardnetworks
Layer 3 routing•Layer3IPv4routing
ProvidesroutingofIPv4atmediaspeed;supportsstaticroutes,RIPandRIPv2,OSPF,IS-IS,andBGP
•RIPandRIPngsupport
ProvidescompletesupportofRIPforbothIPv4andIPv6
•OSPFandOSPFv3support
ProvidescompletesupportofOSPFforbothIPv4andIPv6
•IS-ISandIS-ISv6support
ProvidescompletesupportofIS-ISforbothIPv4andIPv6
•Equal-CostMultipath(ECMP)
Enablesmultipleequal-costlinksinaroutingenvironmenttoincreaselinkredundancyandscalebandwidth
•Layer3IPv6routing
ProvidesroutingofIPv6atmediaspeed;supportsstaticroutes,RIPng,OSPFv3,IS-ISv6,andBGP4+
•IPv6tunneling
AllowsasmoothtransitionfromIPv4toIPv6byencapsulatingIPv6trafficoveranexistingIPv4infrastructure
Page 7Data sheet
•Completemulticastprotocolstack
PIM-DM,PIM-SM,PIM-SSM,MSDP,andextensionstoBGPprovideoneofthemostcompletemulticastprotocolstacks
•Policyrouting
Allowscustomfiltersforincreasedperformanceandsecurity;supportsACLs,IPprefix,ASpaths,communitylists,andaggregatepolicies
•MPLSsupport
ProvidesextendedsupportofMPLS,includingMPLSVPNsandMPLSTrafficEngineering(MPLSTE)
•VPLSsupport
ProvidesextendedsupportofVPLSfordatacentertodatacentercommunicationatLayer2;providessupportofhierarchicalVPLSforscalability
Management•sFlow®
Providesscalable,ASIC-basednetworkmonitoringandaccounting;thisallowsnetworkoperatorstogatheravarietyofsophisticatednetworkstatisticsandinformationforcapacityplanningandreal-timenetworkmonitoringpurposes
•IEEE802.1ABLLDPdiscovery
Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications
•USBsupport
–Filecopy
AllowsuserstocopyswitchfilestoandfromaUSBflashdrive
•Multipleconfigurationfiles
Storeseasilytotheflashimage
•Command-lineinterface(CLI)
Providesasecure,easy-to-useCLIforconfiguringthemoduleviaSSHoraswitchconsole;providesdirectreal-timesessionvisibility
•Logging
ProvideslocalandremoteloggingofeventsviaSNMP(v2candv3)andsyslog;provideslogthrottlingandlogfilteringtoreducethenumberoflogeventsgenerated
•Managementinterfacecontrol
Enablesordisableseachofthefollowinginterfacesdependingonsecuritypreferences:consoleport,telnetport,andSSHport
•Out-of-bandinterface
Isolatesmanagementtrafficfromuserdataplanetrafficforcompleteisolationandtotalreachability,nomatterwhathappensinthedataplane
Page 8Data sheet
•Networkmanagement
HPEIntelligentManagementCenter(IMC)centrallyconfigures,updates,monitors,andtroubleshoots
•Networkmanagement
SNMPv2c/v3MIB-IIwithtraps
•RADIUSaccounting
Logsallsessiondetailsthatcanbeusedtogenerateusagereportsorinterfacetoabillingsystem
•RMON
Providesadvancedmonitoringandreportingcapabilitiesforstatistics,history,alarms,andevents
•RemoteIntelligentMirroring
MirrorsingressACL-selectedtrafficfromaswitchportorVLANtoalocalorremoteswitchportanywhereonthenetwork
Connectivity•IPv6nativesupport
– IPv6host
EnablesswitchestobemanagedanddeployedattheIPv6network’sedge
–Dualstack(IPv4andIPv6)
TransitionsfromIPv4toIPv6,supportingconnectivityforbothprotocols
–MulticastListenerDiscovery(MLD)snooping
ForwardsIPv6multicasttraffictotheappropriateinterface
– IPv6ACL/QoS
SupportsACLandQoSforIPv6networktraffic,preventingtrafficflooding
– IPv6routing
SupportsIPv6staticroutesandIPv6versionsofRIPandOSPFroutingprotocols
Page 9Data sheet
Security•ControlPlanePolicing(CoPP)
ProtectionagainstDoSattacksatinfrastructureroutersandswitches;easeofconfigurationforcontrolplanepolicies
•IEEE802.1XandRADIUSnetworklogins
Controlsport-basedaccessforauthenticationandaccountability
•SecureFTP
Allowssecurefiletransfertoandfromtheswitch;protectsagainstunwantedfiledownloadsorunauthorizedcopyingofaswitchconfigurationfile
•Switchmanagementlogonsecurity
HelpssecureswitchCLIlogonbyoptionallyrequiringeitherRADIUSorTACACS+authentication
•DHCPprotection
BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks
•DynamicARPprotection
BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftofnetworkdata
•SecureShell(SSHv2)
Encryptsalltransmitteddataforsecure,remoteCLIaccessoverIPnetworks
•Securemanagementaccess
Deliverssecureencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2andSNMPv3
•ACLs
ProvideIPv4andIPv6filteringbasedonsource/destinationIPaddress/subnetandsource/destinationTCP/UDPportnumber
•Mediaaccesscontrol(MAC)authentication
Providessimpleauthenticationbasedonauser’sMACaddress;supportslocalorRADIUS-basedauthentication
Convergence•Layers2,3,and4QoSmechanisms
SupportDiffServprioritytaggingbasedonIPaddress,IPTypeofService(ToS),Layer3protocol,TCP/UDPportnumber,andsourceport
•IPmulticastsnoopinganddata-drivenIGMP
AutomaticallypreventfloodingofIPmulticasttraffic
•LLDP-MED
Isastandardextensionthatautomaticallyconfiguresnetworkdevices,includingLLDP-capableIPphones
•InternetGroupManagementProtocol(IGMP)
UtilizesAny-SourceMulticast(ASM)orSource-SpecificMulticast(SSM)tomanageIPv4multicastnetworks;supportsIGMPv1,v2,andv3
•ProtocolIndependentMulticast(PIM)
DefinesmodesofInternetIPv4andIPv6multicastingtoallowone-to-manyandmany-to-manytransmissionofinformation;supportsPIMDenseMode(DM),SparseMode(SM),andSource-SpecificMode(SSM)
Page 10Data sheet
•MulticastSourceDiscoveryProtocol(MSDP)
AllowsmultiplePIM-SMdomainstointeroperate;isusedforinter-domainmulticastapplications
•MulticastVLAN
AllowsmultipleVLANstoreceivethesameIPv4orIPv6multicasttraffic,lesseningnetworkbandwidthdemandbyreducingoreliminatingmultiplestreamstoeachVLAN
Monitor and diagnostics•Portmirroring
Enablestrafficonaporttobesimultaneouslysenttoanetworkanalyzerformonitoring
•Connectivityfaultdetection(IEEE802.1ag)
Connectivityfaultdetection(CFD)providesaLayer2linkOperations,Administration,andMaintenance(OAM)mechanismusedforlinkconnectivitydetectionandfaultlocating
Integration•12500VPN20Gb/sFirewallModule
Providesenhancedstatefulpacketinspectionandfiltering;supportsflexiblesecurityzonesandvirtualfirewallcontainment;deliversadvancedVPNserviceswith3DESandAESencryptionathighperformanceandlowlatency;offersWebcontentfilteringandapplicationprioritizationandoptimization
Investment protection•Modularswitchfabric
Providesinvestmentprotectionbyenablingfutureperformanceupgradesandincreasedportdensity
•Environmentallyfriendly
RoHSsupportandlowpowerconsumptionbasedonthelatesttechnologyprovideoutstandingpowerefficiency
Warranty and support•1-yearwarranty
Seehpe.com/networking/warrantysummaryforwarrantyandsupportinformationincludedwithyourproductpurchase.
•Softwarereleases
Tofindsoftwareforyourproduct,refertohpe.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohpe.com/networking/warrantysummary
HPE 12504 AC Switch Chassis (JC654A) HPE 12504 DC Switch Chassis (JC655A) HPE 12508 AC Switch Chassis (JF431C)
I/O ports and slots 4openmoduleslotsSupportsamaximumof192GigabitEthernetportsor1921/10GbEportsor6440GbEportsor16100GbEports,oracombination
4openmoduleslotsSupportsamaximumof192GigabitEthernetportsor1921/10GbEportsor6440GbEportsor16100GbEports,oracombination
8openmoduleslotsSupportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots4switchfabricslots
2MPU(formanagementmodules)slots4switchfabricslots
2MPU(formanagementmodules)slots9switchfabricslots
Physical characteristicsDimensions
WeightFullconfigurationweight
17.4(w)x27.87(d)x17.4(h)in.(44.2x70.8x44.2cm)(10Uheight)132.28lb(60kg)220.46lb(100kg)
17.4(w)x27.87(d)x17.4(h)in.(44.2x70.8x44.2cm)132.28lb(60kg)220.46lb(100kg)
17.4(w)x29.13(d)x38.39(h)in.(44.2x73.99x97.51cm)(22Uheight)209.44lb(95kg)374.78lb(170kg)
Memory and processorGigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.Telcorackorequipmentcabinet
MountsinanEIA-standard19in.Telcorackorequipmentcabinet
MountsinanEIA-standard19in.Telcorackorequipmentcabinet
PerformanceThroughputRouting/Switchingcapacity
1920Mpps3240Gb/s
1920Mpps3240Gb/s
3840Mpps6120Gb/s
EnvironmentOperatingtemperatureOperatingrelativehumidityNon-operating/StoragetemperatureNon-operating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
Page 11Data sheet
HPE 12500 Switch Series
Specifications
HPE 12504 AC Switch Chassis (JC654A) HPE 12504 DC Switch Chassis (JC655A) HPE 12508 AC Switch Chassis (JF431C)
Electrical characteristicsFrequency
Description
MaximumheatdissipationACvoltage
DCvoltageMaximumpowerrating
50/60Hz
8123BTU/hr(8569.77kJ/hr)100–120/200–240VAC,rated(90–264VAC,max)
2380W
8123BTU/hr(8569.77kJ/hr)
-48to-60VDC2380W
50/60HzAchieved Miercom Certified Green Award10GbEmodulesconsumehalfthepowercomparedtocompetitiveproducts;redundant,scalable,90%efficientpowersuppliesdeliverhighreliabilityinthedatacenter;newASICtechnologyhaslowpowerconsumptionwhenprovidingrichfeatures.14587BTU/hr(15389.29kJ/hr)100–120/200–240VAC,rated(90–264VAC,max)
4750W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
Page 12Data sheet
Specifications (Continued)
Page 13Data sheet
HPE 12504 AC Switch Chassis (JC654A) HPE 12504 DC Switch Chassis (JC655A) HPE 12508 AC Switch Chassis (JF431C)
ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Specifications (Continued)
HPE 12508 DC Switch Chassis (JC652A) HPE 12518 DC Switch Chassis (JC653A)
I/O ports and slots 8openmoduleslotsSupportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
18openmoduleslotsSupportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots9switchfabricslots
2MPU(formanagementmodules)slots9switchfabricslots
Physical characteristicsDimensions
WeightFullconfigurationweight
17.4(w)x29.13(d)x38.39(h)in.(44.2x73.99x97.51cm)(22Uheight)209.44lb(95kg)374.78lb(170kg)
17.4(w)x29.13(d)x66.38(h)in.(44.2x73.99x168.61cm)(38Uheight)352.74lb(160kg)639.33lb(290kg)
Memory and processorGigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.Telcorackorequipmentcabinet
MountsinanEIA-standard19in.Telcorackorequipmentcabinet
PerformanceThroughputRouting/Switchingcapacity
3840Mpps6120Gb/s
8640Mpps13.3Tb/s
Page 14Data sheet
HPE 12500 Switch Series
Specifications
Page 15Data sheet
HPE 12508 DC Switch Chassis (JC652A) HPE 12518 DC Switch Chassis (JC653A)
EnvironmentOperatingtemperatureOperatingrelativehumidityNon-operating/StoragetemperatureNon-operating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
Electrical characteristicsFrequencyMaximumheatdissipationACvoltage
DCvoltageMaximumpowerrating
14587BTU/hr(15389.29kJ/hr)
-48to-60VDC4750W
32859BTU/hr(34666.24kJ/hr)
-48to-60VDC10700W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
Specifications (Continued)
Page 16Data sheet
HPE 12508 DC Switch Chassis (JC652A) HPE 12518 DC Switch Chassis (JC653A)
ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Specifications (Continued)
HPE FlexFabric 12508E AC Switch Chassis (JG782A) HPE FlexFabric 12508E DC Switch Chassis (JG783A)
I/O ports and slots 8openmoduleslotsSupportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
8openmoduleslotsSupportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots9switchfabricslots
2MPU(formanagementmodules)slots9switchfabricslots
Physical characteristicsDimensions
WeightFullconfigurationweight
17.4(w)x29.13(d)x38.39(h)in.(44.2x74.0x97.51cm)(22Uheight)242.51lb(110kg)374.78lb(170kg)
17.4(w)x29.13(d)x38.39(h)in.(44.2x73.99x97.51cm)(22Uheight)209.44lb(95kg)374.78lb(170kg)
Memory and processorGigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.Telcorackorequipmentcabinet
MountsinanEIA-standard19in.Telcorackorequipmentcabinet
PerformanceThroughputRouting/Switchingcapacity
4800Mpps10.8Tb/s
4800Mpps10.8Tb/s
Page 17Data sheet
HPE 12500 Switch Series
Specifications (Continued)
Page 18Data sheet
HPE FlexFabric 12508E AC Switch Chassis (JG782A) HPE FlexFabric 12508E DC Switch Chassis (JG783A)
EnvironmentOperatingtemperatureOperatingrelativehumidityNon-operating/StoragetemperatureNon-operating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
Electrical characteristicsFrequency
Description
MaximumheatdissipationACvoltageDCvoltageMaximumpowerrating
50/60HzAchieved Miercom Certified Green Award10GbEmodulesconsumehalfthepowercomparedtocompetitiveproducts;redundant,scalable,90%efficientpowersuppliesdeliverhighreliabilityinthedatacenter;newASICtechnologyhaslowpowerconsumptionwhenprovidingrichfeatures.14587BTU/hr(15389.29kJ/hr)100–120/200–240VAC,rated(90–264VAC,max)
4750W
14587BTU/hr(15389.29kJ/hr)
-48to-60VDC4750W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
Specifications (Continued)
Page 19Data sheet
HPE FlexFabric 12508E AC Switch Chassis (JG782A) HPE FlexFabric 12508E DC Switch Chassis (JG783A)
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Specifications (Continued)
HPE FlexFabric 12518E AC Switch Chassis (JG784A) HPE FlexFabric 12518E DC Switch Chassis (JG785A)
I/O ports and slots 18openmoduleslotsSupportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination
18openmoduleslotsSupportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots9switchfabricslots
2MPU(formanagementmodules)slots9switchfabricslots
Physical characteristicsDimensions
WeightFullconfigurationweight
17.4(w)x29.13(d)x66.38(h)in.(44.2x73.99x168.61cm)(38Uheight)352.74lb(160kg)639.33lb(290kg)
17.4(w)x29.13(d)x66.38(h)in.(44.2x73.99x168.61cm)(38Uheight)352.74lb(160kg)639.33lb(290kg)
Memory and processorGigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241GbEports)PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAMPowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.Telcorackorequipmentcabinet
MountsinanEIA-standard19in.Telcorackorequipmentcabinet
PerformanceThroughputRouting/Switchingcapacity
10.8Bpps24.3Tb/s
10.8Bpps24.3Tb/s
EnvironmentOperatingtemperatureOperatingrelativehumidityNon-operating/StoragetemperatureNon-operating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)5%to95%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensing
Page 20Data sheet
HPE 12500 Switch Series
Specifications (Continued)
Page 21Data sheet
HPE FlexFabric 12518E AC Switch Chassis (JG784A) HPE FlexFabric 12518E DC Switch Chassis (JG785A)
Electrical characteristicsFrequencyMaximumheatdissipationACvoltageDCvoltageMaximumpowerrating
50/60Hz32859BTU/hr(34666.24kJ/hr)100–120/200–240VAC,rated(90–264VAC,max)
10700W
32859BTU/hr(34666.24kJ/hr)
-48to-60VDC10700W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;RoHSCompliance
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservices,andresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.
Specifications (Continued)
StANDArDS AND PrOtOCOlS(appliestoallproductsinseries)
BGP RFC1657DefinitionsofManagedObjectsforBGPv4RFC1771BGPv4RFC1772ApplicationoftheBGPRFC1773ExperiencewiththeBGP-4Protocol
RFC1774BGP-4ProtocolAnalysisRFC1997BGPCommunitiesAttributeRFC1998PPPGandalfFZACompressionProtocolRFC2385BGPSessionProtectionviaTCPMD5
RFC2439BGPRouteFlapDampingRFC2796BGPRouteReflectionRFC2842CapabilityAdvertisementwithBGP-4RFC2858BGP-4Multi-ProtocolExtensionsRFC2918RouteRefreshCapability
Denial of service protection RFC2267NetworkIngressFiltering AutomaticFilteringofwell-knownDenialofServicePackets
CPUDoSProtectionRateLimitingbyACLs
Device management RFC1155StructureandMgmt.Information(SMIv1)RFC1157SNMPv1/v2cRFC1305NTPv3RFC1945HypertextTransferProtocol—HTTP/1.0RFC2452MIBforTCP6
RFC2454MIBforUDP6RFC2573(SNMPv3Applications)RFC2578-2580SMIv2RFC2579(SMIv2TextConventions)RFC2580(SMIv2Conformance)RFC2819(RMONgroupsAlarm,Event,History,andStatisticsonly)
RFC2819RMONRFC3417(SNMPTransportMappings)SNMPv3andRMONRFCsupportSSHv1/SSHv2SecureShellTACACS/TACACS+
General protocols IEEE802.1adQ-in-QIEEE802.1agServiceLayerOAMIEEE802.1ahProviderBackboneBridgesIEEE802.1DMACBridgesIEEE802.1pPriorityIEEE802.1QVLANsIEEE802.1sMultipleSpanningTreesIEEE802.1vVLANclassificationbyProtocolandPortIEEE802.1wRapidReconfigurationofSpanningTreeIEEE802.1XPAEIEEE802.3ab1000BASE-TIEEE802.3adLinkAggregation(LAG)IEEE802.3ae10-GigabitEthernet
IEEE802.3ahEthernetinFirstMileoverPointtoPointFiber—EFMFIEEE802.3ba40and100GigabitEthernetArchitectureIEEE802.3i10BASE-TIEEE802.3u100BASE-XIEEE802.3xFlowControlIEEE802.3z1000BASE-XRFC768UDPRFC783TFTPProtocol(revision2)RFC791IPRFC792ICMPRFC793TCPRFC826ARPRFC854TELNETRFC868TimeProtocol
RFC903RARPRFC951BOOTPRFC959FileTransferProtocol(FTP)RFC1027ProxyARPRFC1042IPDatagramsRFC1350TFTPProtocol(revision2)RFC1519CIDRRFC1542BOOTPExtensionsRFC1812IPv4RoutingRFC2131DHCPRFC2338VRRPRFC2784GenericRoutingEncapsulation(GRE)RFC2865RemoteAuthenticationDialInUserService(RADIUS)
IP multicast RFC1112IGMPRFC2236IGMPv2RFC2283Multi-protocolExtensionsforBGP-4
RFC2362PIMSparseModeRFC2934ProtocolIndependentMulticastMIBforIPv4RFC3376IGMPv3
RFC3618MulticastSourceDiscoveryProtocol(MSDP)RFC4601PIMSparseMode
Page 22Data sheet
Page 23Data sheet
StANDArDS AND PrOtOCOlS(appliestoallproductsinseries)
IPv6 RFC1350TFTPRFC1981IPv6PathMTUDiscoveryRFC2080RIPngforIPv6RFC2460IPv6SpecificationRFC2461IPv6NeighborDiscoveryRFC2462IPv6StatelessAddressAuto-configurationRFC2463ICMPv6RFC2473GenericPacketTunnelinginIPv6RFC2475IPv6DiffServArchitectureRFC2529TransmissionofIPv6PacketsoverIPv4
RFC2710MulticastListenerDiscovery(MLD)forIPv6RFC2740OSPFv3forIPv6RFC2893TransitionMechanismsforIPv6HostsandRoutersRFC2925DefinitionsofManagedObjectsforRemotePing,Traceroute,andLookupOperations(Pingonly)RFC3315DHCPv6(clientonly)RFC3484DefaultAddressSelectionforIPv6RFC3513IPv6AddressingArchitecture
RFC3587IPv6GlobalUnicastAddressFormatRFC3810MulticastListenerDiscoveryVersion2(MLDv2)forIPv6RFC4251SSHv6ArchitectureRFC4252SSHv6AuthenticationRFC4253SSHv6TransportLayerRFC4254SSHv6ConnectionRFC4541IGMP&MLDSnoopingSwitchRFC4862IPv6StatelessAddressAuto-configuration
MIBs IEEE8023-LAG-MIBRFC1213MIBIIRFC1229InterfaceMIBExtensionsRFC1286BridgeMIBRFC1493BridgeMIBRFC1573SNMPMIBIIRFC1643EthernetMIBRFC1657BGP-4MIBRFC1724RIPv2MIBRFC1757RemoteNetworkMonitoringMIBRFC1850OSPFv2MIBRFC2011SNMPv2MIBforIPRFC2012SNMPv2MIBforTCPRFC2013SNMPv2MIBforUDPRFC2021RMONv2MIBRFC2096IPForwardingTableMIBRFC2233InterfacesMIB
RFC2273SNMP-NOTIFICATION-MIBRFC2452IPV6-TCP-MIBRFC2454IPV6-UDP-MIBRFC2465IPv6MIBRFC2466ICMPv6MIBRFC2571SNMPFrameworkMIBRFC2572SNMP-MPDMIBRFC2573SNMP-TargetMIBRFC2613SMONMIBRFC2618RADIUSClientMIBRFC2620RADIUSAccountingMIBRFC2665Ethernet-Like-MIBRFC2674802.1pandIEEE802.1QBridgeMIBRFC2737EntityMIB(Version2)RFC2787VRRPMIBRFC2819RMONMIBRFC2863TheInterfacesGroupMIB
RFC2925PingMIBRFC2932IP(MulticastRoutingMIB)RFC2933IGMPMIBRFC3273HC-RMONMIBRFC3414SNMP-Userbased-SMMIBRFC3415SNMP-Viewbased-ACMMIBRFC3418MIBforSNMPv3RFC3621PowerEthernetMIBRFC3813MPLSLSRMIBRFC3814MPLSFTNMIBRFC3815MPLSLDPMIBRFC3826AESforSNMP’sUSMMIBRFC4133EntityMIB(Version3)LLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBLLDP-MIB
MPlS RFC2205ResourceReSerVationProtocol(RSVP)—Version1FunctionalSpecificationRFC2209ResourceReSerVationProtocol(RSVP)RFC2702RequirementsforTrafficEngineeringOverMPLSRFC2858Multi-protocolExtensionsforBGP-4RFC3031Multi-protocolLabelSwitchingArchitectureRFC3032MPLSLabelStackEncodingRFC3036LDPSpecificationRFC3107CarryingLabelInformationinBGP-4
RFC3209RSVP-TE:ExtensionstoRSVPforLSPTunnelsRFC3479FaultTolerancefortheLabelDistributionProtocol(LDP)RFC3487GracefulRestartMechanismforLDPRFC4090FastRerouteExtensionstoRSVP-TEforLSPTunnelsRFC4364BGP/MPLSIPVirtualPrivateNetworks(VPNs)RFC4379DetectingMulti-ProtocolLabelSwitched(MPLS)DataPlaneFailuresRFC4447PseudowireSetupandMaintenanceUsingLDP
RFC4448EncapsulationMethodsforTransportofEthernetoverMPLSNetworksRFC4664FrameworkforLayer2VirtualPrivateNetworksRFC4665ServiceRequirementsforLayer2ProviderProvisionedVirtualPrivateNetworksRFC4761VirtualPrivateLANService(VPLS)UsingBGPforAuto-DiscoveryandSignalingRFC4762VirtualPrivateLANService(VPLS)UsingLabelDistributionProtocol(LDP)Signaling
(CONtINuED)
Page 24Data sheet
StANDArDS AND PrOtOCOlS(appliestoallproductsinseries)
Network management IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)IEEE802.1D(STP)RFC1155StructureofManagementInformationRFC1157SNMPv1RFC1215SNMPGenerictrapsRFC1757RMON4groups:Stats,History,Alarms,andEvents
RFC1905SNMPv2ProtocolOperationsRFC2211Controlled-LoadNetworkRFC2272SNMPv3ManagementProtocolRFC2273SNMPv3ApplicationsRFC2274USMforSNMPv3RFC2571SNMPManagementFrameworksRFC2572SNMPv3MessageProcessingRFC2573SNMPv3ApplicationsRFC2576CoexistencebetweenSNMPversions
RFC2578SMIv2RFC2819FourgroupsofRMON:1(statistics),2(history),3(alarm),and9(events)RFC3164BSDsyslogProtocolRFC3415SNMPv3View-basedAccessControlModel(VACM)ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)SNMPv1/v2c/v3
OSPF RFC1245OSPFprotocolanalysisRFC1246ExperiencewithOSPFRFC1587OSPFNSSA
RFC1765OSPFDatabaseOverflowRFC1850OSPFv2ManagementInformationBase(MIB),trapsRFC2328OSPFv2
RFC2370OSPFOpaqueLSAOptionRFC3101OSPFNSSARFC3623GracefulOSPFRestart
QoS/CoS IEEE802.1p(CoS)RFC2212GuaranteedQualityofServiceRFC2474DSFieldintheIPv4andIPv6Headers
RFC2475DiffServArchitectureRFC2597DiffServAssuredForwarding(AF)RFC2598DiffServExpeditedForwarding(EF)
RFC2697ASingleRateThreeColorMarkerRFC2698ATwoRateThreeColorMarkerBidirectionalRateShaping
Security IEEE802.1AEMACSecurityStandard(MACSec)IEEE802.1XPortBasedNetworkAccessControlRFC1321TheMD5Message-DigestAlgorithmRFC2082RIP-2MD5AuthenticationRFC2104Keyed-HashingforMessageAuthentication
RFC2716PPPEAPTLSAuthenticationProtocolRFC2865RADIUSAuthenticationRFC2866RADIUSAccountingRFC2867RADIUSAccountingModificationsforTunnelProtocolSupportRFC2868RADIUSAttributesforTunnelProtocolSupport
RFC2869RADIUSExtensionsRFC3567IntermediateSystem(IS)toISCryptographicAuthenticationAccessControlLists(ACLs)GuestVLANfor802.1XMACAuthenticationSSHv2SecureShellWebAuthentication
IKEv1 RFC2865—RemoteAuthenticationDialInUserService(RADIUS)
(CONtINuED)
Modules HPEFlexFabric12500EMainProcessingUnit(JG802A)HPE12500TypeAMainProcessingUnitwithComwarev7OperatingSystem(JG497A)HPE12500MainProcessingUnit(JC072B)HPEFlexFabric125004-port100GbECFPFDModule(JG786A)HPEFlexFabric125004-port100GbECFPFGModule(JG788A)HPEFlexFabric1250016-port40GbEQSFP+FDModule(JG790A)HPEFlexFabric1250048-port1/10GbESFP+FDModule(JG796A)HPEFlexFabric1250040-port1/10GbESFP+FDModule(JG792A)HPEFlexFabric1250040-port1/10GbESFP+FGModule(JG794A)HPE1250016-port10GbESFP+LEBModule(JC782A)HPE1250016-port10GbESFP+LECModule(JC783A)HPE1250032-port10GbESFP+REBModule(JC064B)HPE1250032-port10GbESFP+RECModule(JC476B)HPE125008-port10GbESFP+LEBModule(JC780A)HPE125008-port10GbESFP+LECModule(JC781A)HPE125008-port10GbESFP+LEFModule(JC659A)HPE1250048-portGig-TLEBModule(JC074B)HPE1250048-portGig-TLECModule(JC065B)HPE1250048-portGbESFPLEBModule(JC075B)HPE1250048-portGbESFPLECModule(JC069B)HPE1250048-portGbESFPLEFModule(JC660A)
HPE 12500 Switch Series accessories
Page 25Data sheet
transceivers HPEX120100M/1GSFPLCLXTransceiver(JF832A)HPEX114100MSFPLCFXTransceiver(JF833A)HPEX1251GSFPLCLH401310nmTransceiver(JD061A)HPEX1201GSFPLCLH401550nmTransceiver(JD062A)HPEX1251GSFPLCLH70Transceiver(JD063B)HPEX1201GSFPRJ45TTransceiver(JD089B)HPEX1201GSFPLCBX10-UTransceiver(JD098B)HPEX1201GSFPLCBX10-DTransceiver(JD099B)HPEX1201GSFPLCLH100Transceiver(JD103A)HPEX1701GSFPLCLH701550Transceiver(JD109A)HPEX1701GSFPLCLH701570Transceiver(JD110A)HPEX1701GSFPLCLH701590Transceiver(JD111A)HPEX1701GSFPLCLH701610Transceiver(JD112A)HPEX1701GSFPLCLH701470Transceiver(JD113A)HPEX1701GSFPLCLH701490Transceiver(JD114A)HPEX1701GSFPLCLH701510Transceiver(JD115A)HPEX1701GSFPLCLH701530Transceiver(JD116A)HPEX1201GSFPLCSXTransceiver(JD118B)HPEX1201GSFPLCLXTransceiver(JD119B)HPEX13010GSFP+LCSRTransceiver(JD092B)HPEX13010GSFP+LCLRMTransceiver(JD093B)HPEX13010GSFP+LCLRTransceiver(JD094B)HPEX13010GSFP+LCER40kmTransceiver(JG234A)HPEX24010GSFP+toSFP+3mDirectAttachCopperCable(JD097C)HPEX24010GSFP+toSFP+5mDirectAttachCopperCable(JG081C)HPEX24010GSFP+SFP+7mDirectAttachCopperCable(JC784C)HPEX14040GQSFP+MPOSR4Transceiver(JG325B)HPEX14040GQSFP+MPOMM850nmCSR4300mTransceiver(JG709A)HPEX14040GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)HPEX14040GQSFP+LCBiDi100mMMTransceiver(JL251A)HPEX150100GCFPLCLR410kmSMTransceiver(JG829A)HPEX13010GSFP+LCLH80kmTransceiver(JG915A)
Cables HPEPremierFlexLC/LCMulti-modeOM42fiber1mCable(QK732A)HPEPremierFlexLC/LCMulti-modeOM42fiber2mCable(QK733A)HPEPremierFlexLC/LCMulti-modeOM42fiber5mCable(QK734A)HPEPremierFlexLC/LCMulti-modeOM42fiber15mCable(QK735A)HPEPremierFlexLC/LCMulti-modeOM42fiber30mCable(QK736A)HPEPremierFlexLC/LCMulti-modeOM42fiber50mCable(QK737A)
Mounting Kit HPEX421ChassisUniversal4-postRackMountingKit(JC665A)
Appliance HPE1250020GbpsVPNFirewallModule(JG371A)
HPE 12500 Switch Series accessories (continued)
Page 26Data sheet
HPE 12500 Switch Series accessories (continued)
Page 27Data sheet
Memory HPEFlexFabric4GBCompactFlashCard(JG806A)HPEFlexFabric4GBDDR3SDRAM(JG807A)HPEX6001GCompactFlashCard(JC684A)HPE2GBRegisteredDDR2SDRAMMemory(JC609A)HPEX6101GBDDR2SDRAMMemory(JC071A)
HPE 12504 AC Switch Chassis (JC654A) HPE1250xG2FabricModule(JC658A)HPE12500ACPowerEntryModule(JF426A)HPE125002000WACPowerSupply(JF429A)HPE12504FanAssembly(JC664A)
HPE 12504 DC Switch Chassis (JC655A) HPE1250xG2FabricModule(JC658A)HPEX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)HPE125001800WDCPowerSupply(JC651A)HPE12504FanAssembly(JC664A)
HPE 12508 AC Switch Chassis (JF431C) HPE12508FabricModule(JC067B)HPE1250xG2FabricModule(JC658A)HPE125002000WACPowerSupply(JF429A)HPE12500ACPowerEntryModule(JF426A)
HPE 12508 DC Switch Chassis (JC652A) HPE12508FabricModule(JC067B)HPE1250xG2FabricModule(JC658A)HPEX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)HPE125001800WDCPowerSupply(JC651A)
HPE 12518 DC Switch Chassis (JC653A) HPE12518G2FabricModule(JC657A)HPE12518FabricModule(JC066A)HPEX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)HPE125001800WDCPowerSupply(JC651A)
HPE FlexFabric 12508E AC Switch Chassis (JG782A) HPEFlexFabric12508EFabricModule(JG798A)HPEFlexFabric12508EOptionalExtendedCableGuideforACPoweredSwitch(JG830A)HPEFlexFabric12508EOptionalExtendedCableGuideforDCPoweredSwitch(JG832A)HPE125002000WACPowerSupply(JF429A)HPEFlexFabric12500ESparePowerMonitorModule(JG804A)HPEFlexFabric12500EFanTrayAssembly(JG805A)HPEFlexFabric12508EOptionalAirFilter(JG808A)
Ratethisdocument
Sign up for updates
Data sheet
©Copyright2010–2016HewlettPackardEnterpriseDevelopmentLP.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHewlettPackardEnterpriseproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HewlettPackardEnterpriseshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.
MicrosoftiseitheraregisteredtrademarkortrademarkofMicrosoftCorporationintheUnitedStatesand/orothercountries.sFlowisaregisteredtrademarkofInMonCorp.
4AA3-0666ENW,February2016,Rev.15
HPE FlexFabric 12508E DC Switch Chassis (JG783A) HPEFlexFabric12508EFabricModule(JG798A)HPE12508TopandBottomCableGuidesforDCPoweredSwitch(JC787A)HPE12500SideCableManagementGuide(JC084A)HPEX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)HPEFlexFabric12508EOptionalExtendedCableGuideforDCPoweredSwitch(JG832A)HPE125001800WDCPowerSupply(JC651A)HPEFlexFabric12500ESparePowerMonitorModule(JG804A)HPEFlexFabric12500EFanTrayAssembly(JG805A)HPEFlexFabric12508EOptionalAirFilter(JG808A)
HPE FlexFabric 12518E AC Switch Chassis (JG784A) HPEFlexFabric12518EFabricModule(JG800A)HPE12518TopandBottomCableGuidesforACPoweredSwitch(JC786A)HPE12500SideCableManagementGuide(JC084A)HPEFlexFabric12518EOptionalExtendedCableGuideforACPoweredSwitch(JG831A)HPE125002000WACPowerSupply(JF429A)HPE12500ACPowerEntryModule(JF426A)HPEFlexFabric12500ESparePowerMonitorModule(JG804A)HPEFlexFabric12500EFanTrayAssembly(JG805A)HPEFlexFabric12518EOptionalAirFilter(JG809A)
HPE FlexFabric 12518E DC Switch Chassis (JG785A) HPEFlexFabric12518EFabricModule(JG800A)HPE12518TopandBottomCableGuidesforDCPoweredSwitch(JC788A)HPE12500SideCableManagementGuide(JC084A)HPEX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)HPEFlexFabric12518EOptionalExtendedCableGuideforDCPoweredSwitch(JG833A)HPE125001800WDCPowerSupply(JC651A)HPEFlexFabric12500ESparePowerMonitorModule(JG804A)HPEFlexFabric12500EFanTrayAssembly(JG805A)HPEFlexFabric12518EOptionalAirFilter(JG809A)
HPE 12500 Switch Series accessories (continued)
ProductswithinthisserieshaveachievedsufficientscoresineachoftheratedcriteriatoachievetheMiercomCertifiedGreendistinctionAward.SeetheSpecificationssectionofthisseriesformoreinformation.
Learnmoreathpe.com/networking