IMPORTANT INFORMATION - docs-emea.rs … Fused Spur is a double pole Residual Current Device (RCD)...

Post on 20-Apr-2018

215 views 2 download

transcript

60.3 REF

86.0

86.0

TOP TERMINALS = SUPPLY

BOTTOM TERMINALS = LOAD

IMPORTANT INFORMATION

13.5 REF

27.2

D

E

C

B

A

321 54 6 8

H92WPA Product Specification GB400343SHEET 1 OF 3

SCALE: 1:1

DWG NO.TITLE:

AN

D D

ESIG

N G

REEN

BRO

OK

ELEC

TRIC

AL

PLC

. CO

NTE

NTS

STR

ICTL

Y PR

IVA

TE A

ND

CO

NFI

DEN

TIAL.

TO

BE

USED

ON

LY F

OR

THE

PURP

OSE

S N

OTIF

IED

BY

GRE

ENBR

OO

K EL

ECTR

ICA

L PL

C. O

R ITS

LIC

ENC

EE.

ALL

INTE

LLEC

TUA

L PR

OPE

RTY

IN A

ND

IN R

ELA

TION

TO

THI

S D

RAW

ING

AN

D IT

S SU

BJEC

T M

ATT

ER A

RE R

ESER

VED

, AN

D H

EREB

Y LI

CEN

CED

TO

GRE

ENBR

OO

K EL

ECTR

ICA

L PL

C.

ISS CCD DATE

DO NOT SCALE THIS DRAWINGDRAWN BY C.EGREENBROOK

WEST ROAD, HARLOWESSEX CM20 2BG UK

A 102 22/12/10

MATERIAL:FINISH:

PROJECTION THIRD ANGLE. IF IN DOUBT ASK

TOLERANCES(UNLESS STATED OTHERWISE)

- 1 DEC PLACE 0.4- 2 DEC PLACE 0.1- ANGULAR 1.0

DRAFT CONSIDERATIONS(S) - SMALLEST DIMENSION(L) - LARGEST DIMENSIONGENERAL - 1 PER SIDE 0.5

ALL DIMENSIONS IN MILLIMETERS

7

A3G

B

DESC

RIPTIO

N - H

92WPA

- RC

D Fused Spur - W

hite

The Fused Spur is a double pole R

esidual Current D

evice (RC

D) in the form

of a 13 amp

device. It is designed and manufactured to the requirem

ents of BS

1363-4 & B

S7288.

The product is based upon a generic design and construction with variations to include:

White P

lastic face plate version for domestic m

achines in the home.

Metal clad enclosure variant for the m

ore robust applications.

CLA

SSIFICA

TION

RC

D Fused S

purD

ouble Pole break

Mechanically latched ( contacts rem

ain closed when m

ains power is rem

oved and re-applied) - generally defined as “Passive”C

LAS

S 2 device.

BR

ITISH A

ND

EUR

OPEO

N STA

ND

AR

DS

Current S

tandardsB

S7288 :1990 A

md 1( socket out-lets incorporating S

RC

D`s )

BS

1363-4:1995 Am

d 1, 2, 3 (Specification for 13A

Fused connection units switched and unsw

itched) E

MC

:E

missions: E

N 55014-1:2006 &

EN

55014-1:2000 inc A1:2001 &

A2:2002

Imm

unity: EN

61543:1995 inc A11:2003, A

12:2005 & A

2:2006

RA

TING

Voltage 230 V

olts AC

Current (m

ax) 13 Am

p Resistive &

InductiveFrequency 50 H

ertzE

nvironmental IP

40 (Ingress Protection R

ating)Trip C

urrent 30 mA

maxim

um 22 m

A typical

Non Trip C

urrent 15 mA

max

Trip Speed 20 m

Seconds

Circuit fault break current 1500A

mps

Earth fault break current 250 A

mps

DESIG

N FEA

TUR

ES

Fuse Holder can be locked out for safety.

Twin earth term

inals.Integral cord outlet and cable clam

p.(4.6 to 10.4mm

max D

ia cable)W

hite Button: S

witches m

echanism “O

N”

Trip indication: Red flag and light - visible only w

hen mechanism

ON

(closed contacts)G

rey Test Button: A

ctivates mechanism

to “OFF”

Enclosure: Front plate - R

obust hard to scratch material - com

pression thermoset plastic. C

olour - 'White'.

Rear m

olding: Nylon 7, C

olour “Black”

INSTA

LLATIO

N &

TESTING

System

Install in-line with the 17th E

dition Wiring R

egulations.R

outine Testing Assum

ing the device has been installed correctly the RC

D should be tested regularly, each tim

e before use, as follows:-

Press W

hite button fully in and releaseW

indow indicator show

s “RE

D” and illum

inates.P

ress Grey Test button fully in and release.

Window

indicator has turned WH

ITE (no illum

ination )

In this test the device has latched ready for use and then has been tested using the in built test function. Device is now

ready for normal use.

To Use - P

ress and release White button. R

ed flag and illumination w

ill be displayed in the respective window

..R

CD

Perform

ance Testing. RC

D testers (R

OB

IN K

MP

5406) are available for this purpose.C

ircuit Insulation, Resistance and E

arth Fault loop impedance Testing:

It is important that the device is disconnected during these tests

otherwise the internal electronics m

aybe damaged.

SERVIC

E CO

ND

ITION

S

Temperature -5 to +40 degrees C

Altitude 2000m

max (above sea level)

Abnorm

al conditions Avoid pollution by sm

oke, chemical and flam

mable fum

es,S

alt laden spray, periods of high humidity, greater 95%

Relative H

umidity (R

.H.)

D

E

C

B

A

321 54 6 8

H92WPA Product Specification GB400343SHEET 2 OF 3

SCALE: 1:1

DWG NO.TITLE:

AN

D D

ESIG

N G

REEN

BRO

OK

ELEC

TRIC

AL

PLC

. CO

NTE

NTS

STR

ICTL

Y PR

IVA

TE A

ND

CO

NFI

DEN

TIAL.

TO

BE

USED

ON

LY F

OR

THE

PURP

OSE

S N

OTIF

IED

BY

GRE

ENBR

OO

K EL

ECTR

ICA

L PL

C. O

R ITS

LIC

ENC

EE.

ALL

INTE

LLEC

TUA

L PR

OPE

RTY

IN A

ND

IN R

ELA

TION

TO

THI

S D

RAW

ING

AN

D IT

S SU

BJEC

T M

ATT

ER A

RE R

ESER

VED

, AN

D H

EREB

Y LI

CEN

CED

TO

GRE

ENBR

OO

K EL

ECTR

ICA

L PL

C.

ISS CCD DATE

DO NOT SCALE THIS DRAWINGDRAWN BY C.EGREENBROOK

WEST ROAD, HARLOWESSEX CM20 2BG UK

A 102 22/12/10

MATERIAL:FINISH:

PROJECTION THIRD ANGLE. IF IN DOUBT ASK

TOLERANCES(UNLESS STATED OTHERWISE)

- 1 DEC PLACE 0.4- 2 DEC PLACE 0.1- ANGULAR 1.0

DRAFT CONSIDERATIONS(S) - SMALLEST DIMENSION(L) - LARGEST DIMENSIONGENERAL - 1 PER SIDE 0.5

ALL DIMENSIONS IN MILLIMETERS

7

A3G

B

CONNECTIONS

L N E Notes Trip Damaged after connected Test Button Protection Output LED

L N E Correctly connected No No Functional OK ON

L E N Earth and Neutral reversed No No Functional OK ON

N L E Line and Neutral reversed No No Functional OK ON

N E L Line to Earth, always dangerous No No Not Functional OK ON (weak brightness)

E N L Line to Earth, always dangerous No No Not Functional OK ON (weak brightness)

E L N No No Functional OK ON

L N - Earth not connected No No Functional OK ON

N L - Earth not connected No No Functional OK ON

L - E Neutral not connected No No Not Functional OK ON (weak brightness)

E - L Neutral not connected No No Not Functional OK ON (weak brightness)

- N E Line not connected No No Not Functional no leakage current occur OFF

- E N Line not connected No No Not Functional no leakage current occur OFF

L E Dangerous No No Not Functional OK ON (weak brightness)

D

E

C

B

A

321 54 6 8

H92WPA Product Specification GB400343SHEET 3 OF 3

SCALE: 1:1

DWG NO.TITLE:

AN

D D

ESIG

N G

REEN

BRO

OK

ELEC

TRIC

AL

PLC

. CO

NTE

NTS

STR

ICTL

Y PR

IVA

TE A

ND

CO

NFI

DEN

TIAL.

TO

BE

USED

ON

LY F

OR

THE

PURP

OSE

S N

OTIF

IED

BY

GRE

ENBR

OO

K EL

ECTR

ICA

L PL

C. O

R ITS

LIC

ENC

EE.

ALL

INTE

LLEC

TUA

L PR

OPE

RTY

IN A

ND

IN R

ELA

TION

TO

THI

S D

RAW

ING

AN

D IT

S SU

BJEC

T M

ATT

ER A

RE R

ESER

VED

, AN

D H

EREB

Y LI

CEN

CED

TO

GRE

ENBR

OO

K EL

ECTR

ICA

L PL

C.

ISS CCD DATE

DO NOT SCALE THIS DRAWINGDRAWN BYGREENBROOK

WEST ROAD, HARLOWESSEX CM20 2BG UK

A 102 22/12/10

MATERIAL:FINISH:

PROJECTION THIRD ANGLE. IF IN DOUBT ASK

TOLERANCES(UNLESS STATED OTHERWISE)

- 1 DEC PLACE 0.4- 2 DEC PLACE 0.1- ANGULAR 1.0

DRAFT CONSIDERATIONS(S) - SMALLEST DIMENSION(L) - LARGEST DIMENSIONGENERAL - 1 PER SIDE 0.5

ALL DIMENSIONS IN MILLIMETERS

7

A3G

B