KESSEL - Leading in Drainage 2 · Illustration and dimensioned drawing Article description Lifting...

Post on 25-Mar-2020

1 views 0 download

transcript

Article descriptionIllustration and dimensioned drawing

Lifting station Aqualift S Tronic / Aqualift S Duofor sewage free wastewater, made of polymerFor installation in a concrete slab/floor, Installation depth (D) 481 mm to 656 mm.With telescopic upper section for continuous height and level adjustment, recessed cover for on-sitetiling, made of polymer, Class A 15, with moisture protective sealing flange,integrated backwater flap.Pressure connection: 11/2 inch outer thread, Pressure pipe Ø 40 mm for PVC glued connection or pressure pipe set.Max. particle size: 10 mm. max. pumping height: 8 m.Voltage: 230 V ~ 50 Hz.

Aqualift S Tronic with removable pump and probecontrol for conductive fluids, with control unit,Intake power: 0.5 kW. Power cable: 5 m. Weight: approx. 19 kg.

Aqualift S Duo with two removable pumps and air pressure control, with control unit,Intake power: 2 x 0.5 kW. Power cable: 5 m. Weight: approx. 26 kg. With potential-free contact.Probe control not to be used for stormwater.Special solutions available on request.

Ø 40 28 550

Ø 40 28 530

Installation area 700 x 700 mm

Lifting station Aqualift S Tronic / Aqualift S Duofor sewage free wastewaterFor installation in a concrete slab/floor, according to EN 12056

Was

tew

ater

lif

ting

sta

tion

s fo

r in

teri

or i

nsta

llati

onSu

bmer

sibl

e pu

mps

Lift

ing

stat

ions

fo

r ex

teri

or i

nsta

llati

onLi

ftin

g st

atio

ns

for

inte

rior

ins

talla

tion

Article descriptionIllustration and dimensioned drawing

Lifting station Aqualift Sfor sewage free wastewater, made of polymerFor installation in a concrete slab/floor, Installation depth (D) 481 mm to 656 mm.With telescopic upper section for continuous height and level adjustment, recessed cover for on-sitetiling, made of polymer, Class A 15, with moisture protective sealing flange,with removable pump and float control, integrated backwater flap.Pressure connection: 11/2 inch outer thread, Pressure pipe Ø 40 mm for PVC glued connectionor pressure pipe set.max. pumping height: 8 mVoltage: 230 V ~ 50 HzIntake power: 0.5 kWPump on level: 200 mmPump off level: 85 mmMax. particle size: 10 mmPower cable: 5 mWeight: ca. 19 kg

Ø 40 28 500

Lifting station Aqualift Sfor sewage free wastewaterFor installation in a concrete slab/floor, according to EN 12056

Article #Ø

Article #Ø27

- 2

02

Ø 4

0

PD

EN 12050 -2guaranteed with

tested quality

Type-testedand monitored

LGA

EN 12050 -2guaranteed with

tested quality

Type-testedand monitored

LGA

27 -

202

Ø 4

0

P D

Optional:Multistop odour, foam, rodentand insect stop, page 39

Hair filter page 39

Optional:Audible alarm page 51Potential-free contact page 51Multistop odour, foam, rodent

and insect stop, page 39Hair filter page 39

258

Ø 590

Ø 4

0

33045

4D

400

27 -

202

Art. # 28 550

Art. # 28 530

Installation area 700 x 700 mm

Jansen Pompentechniek T: +31(0)485-371318 E: info@pompentechniek.nl

susan
Draft
susan
Draft

Was

tew

ater

lif

ting

sta

tion

sfo

r in

teri

or i

nsta

llati

on

Lift

ing

stat

ions

fo

r ex

teri

or i

nsta

llati

on

Lift

ing

stat

ions

for

inte

rior

ins

talla

tion

Subm

ersi

ble

pum

ps

Cover plate made of polymersurface water tight, black, Class A 15. Ventilation pipe necessary, incl. gasket 173-145surface water tight, recessed for on-site tiling, grey,for tile thicknesses of 18 mm, Class A 15with integrated grating, black, Class A 15

- 83 052

- 83 053

Extension section with flangemade of polymermax. extension 180 mm, including gasketIntegrated floor drain outlet extendable on-site with HT pipe Ø 50. For gasket set Art. # 83 023

Odour trap made of polymer50 mm seal water heightIt is also necessary to use a ventilation pipe

- 83 071

Pressure pipe setIncl. 5 m pressure pipe hose Ø 40, Adaptor with pipe clamp

Alarm Type 20220 / 20 221with electrode probe for Art. # 28 500

with optical probe for Art. # 28 500

- 83 023Gasket set consisting of:Counter flange made of polymer, incl. screwsElastomer waterproof membrane in NK/SBR Ø 800 mm

Pipe sealing gasket(EPDM)

Hole saw Ø 50, 75, 110 for drilling

Ø 50 850 114Ø 75 850 116Ø 110 850 117

- 50 101

- 47 200

- 83 050

Ø 40 28 040

Lifting station Aqualift Sfor sewage free wastewaterFor installation in a concrete slab/floor, according to EN 12056

Performance diagram Aqualift S-Pump Deep installation

D max. = 800 mmfrom 661 - 836 mm

258

� 4

0

�400

H

H = 468 - 638 mm

Extension section Art. # 83 071Current

typeAlternating

current

Voltage

230 V

Current

2.2 A

Motor rating P1 / P2

480 W / 310 W

RPM

2800 min-1

Motor pro-tection

integrated

Plug

Schuko5 m cable

� Odour trap can beretrofitted

Ø Article #Accessories

Three functions...� Lifting station for waste-

water without sewage � Discharge, even with a

fractured pipe or incomingflood water

� Chamber ready to beinstalled, can even beinstalled in waterproofconcrete

D

�414

40

230

180

�59010

-

-

20 220

20 221

50

�100

Extension sectionmade of polymer, max. extension 180 mm, incl. gasket

When multiple extension section are used make surethat access to valve is still possible !

- 83070

Cover plate with drain Ø 75, Class A 15

recessed for on-site tiling, grey,for tile thicknesses of 18 mm

- 83 055

480

414

150

200

0,0

1,0

2,0

3,0

4,0

5,0

6,0

7,0

8,0

0,0 1,0 2,0 3,0 4,0 5,0 6,0 7,0 8,0

12345

76

1 2 3 4 5 6 7 [Qm3/h]

[m]

Pum

ping

hei

ght m

Pumping capacity Q (m3/h)

waterproofconcrete

Idealwaterproofconcrete

Idealfor

KESSEL - Professional advantages

Jansen Pompentechniek T: +31(0)485-371318 E: info@pompentechniek.nl