LiquiTech Solutions Company Profile Booklet

Post on 28-Mar-2016

251 views 0 download

Tags:

description

The 2011 Updated Company System Profile for LiquiTech Solutions. The company specializes in water disinfection solutions with a Copper/Silver Ioniziation technology.

transcript

Prepared for The United States Department of Veteran Affairs

MedicalgradewaterdisinfectionsolutionsservingHealthcare,Hospitality,Commercial,IndustrialandGovernmentFacilities.

Company&SystemProfile

+

For proposal requests contact: TonyDiefenbach

Director,BusinessDevelopment421EisenhowerLaneSouth,Lombard,IL60148

Tel:800•635•7873Fax:630•693•0505tdiefenbach@liquitech.netwww.liquitech.net

AboutOurCompany 1

TheProblem 3

OurSolutions 4

TheLiquidator®System 5

Specifications 7

ProductComparison 9

References 10

Contents

i

LiquiTech, Inc. 421EisenhowerLaneSouth,Lombard,Illinois60148

(P)800.635.7873|(F)630.693.0505|tdiefenbach@liquitech.net

+Our Company

LiquiTechstrivestoprovideinnovativeenvironmentalsolutionstotheworld.Essentialtoanyofourendeavorsisthefocusweplaceonthehealthandsafetyofourcustomersandtheglobalcommunity.Wesupplyonlythebestwatersafetysolutionswhilemaintainingourdedicationtotheenvironment.AtourheadquartersinLombard,Illinoiswemanufactureandshipourcoppersilverionizationsystemstosomeofthemostprestigioushealthcare,hospitality,commercial,industrialandgovernmentfacilitiesaroundtheglobe.Todate,wehaveover1,200installationsin15differentcountries.Effective. Safe. Environmentally Friendly.HereatLiquiTechwedonotbelieveinchemicalsthatyieldmoderateresultswithleftoverharmfulbyproducts.Inouropinion,chemicalwatertreatmentsarenotasolutionbutratheracompromisethattradesoneproblemforanother.Instead,wefocusonprovidingwaterdisinfectionsolutionsthatutilizecopper/silverionizationtostopwaterbornepathogens.Partners In Action.Buildingstrong,long-termrelationshipsistheonlywaytoconductbusiness.AtLiquiTech,webelieveeveryoneisapartnerorstakeholdertobeconsideredinourstrategies,actions,andofferings.

-1-

Quality. Expertise. Improvement. Integrity. QUALITY:LiquiTechoffersonlythehighestqualityproductsandservices.Pinnacleinourpursuitsisthededicationwehavetoservingourcustomersandensuringtheirsatisfaction.EXPERTISE:Withover18yearsofexperience,ourengineersandtechniciansarethemostknowledgeablearound.Weworktirelesslytobetheabsolutebestatwhatwedo.Technicalserviceandsupportisalwaysavailable:24hoursaday,7daysaweek,365daysayear.IMPROVEMENT:Ifhistoryandhumannaturehavetaughtusanythingit’sthatthereisalwaysabetter,moreefficientwayofachievinggoals.AtLiquiTech,weseektoembracethisphilosophyandmakeitacornerstoneofthewayweconductbusinesseveryday.Weareconstantlyresearchingandcontinuouslydesigningnewsolutionstoaddtoourexistingofferings.INTEGRITY:AtLiquiTech,wealwaysprovideourcustomerswithcompleteandaccurateinformation,neversettlingforhalf-truths.Researchandeducationofallpossiblealternativesisstronglyencouragedinordertofacilitatethebestdecision.Wearehappytoofferourcustomersourresourcesaswellasindependent,thirdpartysourcestocompareandverifyanyinformation.Itisourpledgetoalwaysmakeyourinterestsourinterests.

2 Company Profile 2011

Core Values

Addressing Waterborne Pathogens:

AsoftodayASHRAE,OSHA,TheJointCommissionandtheCDCarealladdressingthecontrolandpreventionofwaterbornepathogens,specificallyLegionella.Researchindicatesthatthesepathogenscanbecontrolledwithproperwatersystemdesignandpreventativemeasures.Legionella

LegionnairesdiseaseisasevereandpotentiallyfatalpneumoniacausedbyatypeofbacteriacalledLegionella.TransmissionofLegionellaoccursbymeansofaerosolizationoraspirationofwatercontaminatedwithLegionellaorganisms.SystemslinkedtothetransmissionofLegionellaincludepotablewaterdistributionsystems(shower,faucets,ect.),coolingtowers,humidifiers,respiratorytherapyequipment,whirlpoolspas,andevaporativecondensers.

Since2001,theCDCsurveillancereportshavestatedthatLegionellahasbecomethesinglemostcommonlyreportedpathogenassociatedwithdrinkingwateroutbreaksintheUnitedStates.Duringthe2005-2006CDCSurveillanceperiod,100%ofthewaterbornediseaseoutbreaksassociatedwithLegionellaoccurredasaresultofLegionellacolonizationinplumbingandpipesand80%ofthemoccurredinahealthcaresetting.Pseudomonas

Pseudomonasisanopportunisticpathogen.Thispathogenisnaturallyfoundinsoil,water,plantsandanimals(includinghumans).Itrarelycausesdiseaseinhealthypersons.Pseudomonasisthemostcommonpathogenisolatedfrompatients

The Problem

whohavebeenhospitalizedlongerthanoneweek.ItisthefrequentcauseofHAIssuchaspneumonia,urinarytractinfections,andbacteremia.InfectionscausedbyPseudomonasarecomplicatedandcanbelifethreatening.A2002studyconcludedthat36-42%ofhealthcareassociatedPseudomonasinfectionsarepossiblyduetocontaminatedtapwater.Additionally,itisthenumberonecauseofintensivecarerelatedpneumoniaandthenumbertwocauseofallhospitalacquiredpneumoniasTheseinfectionsareassociatedwithanextremelyhighmortalityrate,upto68%.Addressing Hospital Acquired Infections:

EvidenceofthesignificantproblemofHospitalAcquiredInfections(HAIs),intermsofbothlivesandhealthcarecosts,continuestogrow.Manyhospitaladministratorsbelievetheycannotaffordtotakethenecessarystepstoinstallapreventativesystem.Thetruthis,theycan’taffordnotto.HAIsdramaticallyerodehospitalprofitseachyear.Preventionstrategiesandtechnologiesaresavinghospitalsmillionsofdollarsand,moreimportantly,countlesslives.

HospitalwatersystemsareoftenanoverlookedsourceofHAIs.WaterbornepathogenssuchasLegionella,Pseudomonas,Staphylococcus,andotherdeadlybacteriainfiltratehospitals’plumpingandactasunsuspecteddeliverysystems.Thebacteriacanenter,takeroot,andflourishquicklyatanytimewithoutnotice,untilpatientsand/oremployeesstartgettingsick.ThisisjustoneofthemanyreasonswhyaLiquiTech®systemisakeycomponentinpreventingHAIs.

+

-3-

4 Company Profile 2011

Our SolutionsLiquiTechisdedicatedtoprovidingtheabsolutebest,mostenvironmentallyfriendlymethodsforeradicatingwaterbornepathogensthatenableyou,thecustomer,to:

Be Proactive.RiskAssessment

Clean,safewaterisacornerstoneofqualityserviceinanyfacility.Anhonestandcomprehensiveassessmentofyourwatersystemwillgiveyouanaccuratepictureofhowyourfacilityismeetingthisbasicneedandidentifyanyrisksforpotentiallydangeroussituations,includingbacterialoutbreak.LiquiTech,arecognizedleaderinfacilitywaterconsultationandanalysis,canhelpgiveyoupeaceofmindwhenitcomestoyourwatersystem.LegionellaTesting

LiquiTechisatrustedleaderintestingandtreatmentofLegionellaandotherbacteriainfacilitywatersystems.LegionellaisabacteriumspeciesthatarethecausativeagentofthehumanLegionairesdiseaseandthelesserform,Pontiacfever.Commonsourcesincludecoolingtowers,swimmingpools,domestichot-watersystems,fountains,andsimilardisseminatorsthattapintoapublicwatersupply.DiseaseformLegionellatendstoleadtoharmfulsymptoms,andoftentimesdeath,especiallyinthosewithacompromisedimmunesystemandtheelderly.IntheUnitedStatesalonethediseaseaffectsbetween8,000and18,000individualsayear.Consequently,itshouldbeactivelycheckedforinanywatersystem.

BeEquipped.

OurLiquidator®copper/silverionizationsystemsarethesafest,mostenvironmentallyfriendlywaytoprotectanyfacilityfromlifethreateningwaterbornepathogens.Weprovidecustom,in-housefabricationofeachandeveryoneofoursystemsinordertoprovideourcustomerswithaproductdesignedwiththeirfacility’sneedsandspecificationsinmind.BeInformed.

AtLiquiTech,wearededicatedtostayingonthecuttingedgeofenvironmentallyfriendlywatersafetysolutionsandwestrivetoextendthisknowledgetoourentireconsumerbase.Asinnovatorsinthisindustrywefeelitisourdutytokeepourcustomersandaffiliates“intheknow”

regardingstandardsofcare,bestpractices,andinnovativewaystocombatwaterbornepathogens,allwhilereducingenergyandcosts.

BeMaintained.

InrecentyearsLiquiTechhasgonefarandabovetheindustrystandardbyintroducingourMaintenance,MonitoringandService(MMS)programtomakeoursystemsaturn-keyinvestmentforanyfacility.

The Equipment.

OurLiquidator®systemconsistsoffourmaincomponents:thecontrolunit,flowcell,flowmeter,andremoteengineermanagementsystem(REMS).All LiquiTech® components are NSF certified.

Our System+

1. Control UnitTheLiquiTech®electroniccontrolunitcanbeconfiguredtocontrol output current levels bymultiplemethods,whichdirectly relates to the amount of ions released into thewater.Suchmethodsincludecurrentsetpointswhichwillmaintainthecurrentaccordingtoitssetpointindefinitely,internaltimerfunctionswhichcanbeprogrammedforeverydayoftheweektooperateonlyatspecificintervals,remotecontact input such as a flow switch, and analog inputsfromsources such as a flowmeter or a copper analyzer.Shouldanyuser-configuredtrippointsoccurorfailuresbedetected,twoindependent120volt10ampalarmrelaysareprovidedforremotefunctions.

3. Flow MeterThe LiquiTech® computerized electronic control units aresupplied with “closed-loop proportional control” whichautomaticallyproducespreciselevelsofcopperandsilverionsproportionaltoflowrates(waterconsumption)measuredbyaflowmeter.Itisinstalledinthecoldwatermakeuptotheheatsourceorthehotwatersupplytothefacility,whicheverismostpractical.Thecopperanalyzerisinstalledtosamplecopper levels inthehotwaterstoragetankorrecirculationsystem.TheflowmeterssuppliedareBlue-WhiteIndustriesSonic-Pro™S3CHybridUltrasonicflowmeters.

2. Flow CellThe flow-cells housing the copper/silver electrodes arecomprisedofhightemperature,highpressure,schedule80CPVC.ElectrodespacersarefabricatedfromDuPontPBT polyester resin. The flow-cells are supplied withLiquiTech®quick-connectstainlesssteelclampsforeaseofinstallation.Flow-cellsareavailableinvarioussizesandconfigurationsdependingupontheapplication.Standard150-pound flangeswith 304 stainless steel nuts, boltsand washers are also available. The entire LiquiTech®ElectronicDisinfectionSystemincludingController,Flow-Celland interconnectingwire isETL(UL-508and1081)certified.LiquiTech®productsconformtotheEuropeanUnion EMC Directive 89/336/EEC and the Low VoltageDirective72/23/EECandbeartheCEMark.

-5-

4. Remote Engineer Management SystemOurLiquidator®systemsarecapableofremotesupervisorycontrolviainternetaccessthroughalocalnetwork.Theseremote functions include real time display and alarms,system diagnostics, system configuration, remote datalogging,andallcontrolfunctionadjustments.

6 Company Profile 2011

Certifications

AtLiquiTechwehavetakengreatprideindevelopingthehighestqualitysystemsavailable.Therefore,LiquiTechhasobtainedCE,NSF,CSA,EPAandETL/ULcertification,registrationorapprovalonalloursystems.LiquiTechalsocomplieswithapplicablecodesandregulations.TheentireLiquiTech®ElectronicDisinfectionSystemincludingControlmodule,FlowCellandinterconnectingwireareETL(UL-508and1081)certifiedandCSAC22.2No.14-95and108-M89certified.LiquiTechisregisteredasapesticideproducingdeviceunderEPAregistrationnumber068250.LiquiTechproductsconformtotheEuropeanUnionEMCDirective89/336/EECandtheLowVoltageDirective72/23/EECandbeartheCEMark.

The Process.

Aswaterpassesthroughtheflowcell,adirectcurrentisappliedacrosstheelectrodestostimulatethecontrolledreleaseofions.Therateatwhichtheionsarereleasedisautomaticallymaintainedbyasolid-state,microprocessor-basedcontrolunitthatisbothreliableandeasytooperate.TheionemissionsoftheLiquiTech®ionizationprocessarecationic,surface-activeandapotentbiocide.Thedisinfectionactionisattributabletothepositivelychargedcopperandsilverionswhichformelectrostaticbondswithnegativelychargedsitesonmicroorganismcellwalls.Theseelectrostaticbondscreatestressesthatleadtodistortedcellwallpermeability,reducingthenormalintakeoflifesustainingnutrients.Thisaction,coupledwithproteindenaturation,leadstocelllysisanddeath.Theaccuratedose-ratecontrolsystemmaintainspreciseionlevels,providingresidualprotectionandpreventionofrecontamination.ItisthisresidualprotectionthatmakestheLiquiTech®systemsuperiortoallotherdisinfectionmethods.

Model: QF14-/4 QF7-/4 QLTF42-/3Cell Length: 16.25” 12.25” 11.625”Overall Length: 28.25” 24.25” 22.625”Cell Diameter (ID): 4” 4” 3”Threaded Adapter: 3” 3” 2”Electrodes: 2 2 2Electrode Length: 14” 7” 7”Cell Weight: 24.0lbs. 14.0lbs. 8.0lbs.Overall Weight: 39.0lbs. 30.0lbs. 15.0lbs.Working Pressure:@120°F 208PSI 208PSI 240PSI@150°F 150PSI 150PSI 173PSI @180°F 80PSI 80PSI 92PSIMaterials: Schedule80CPVC(allmodels)Connection: Quick-connect,powder-coated304stainlesssteelclampconnections standard.Mustbetightenedtotorqueof10ft.lbs.;torquewrenchand6mm hexbitprovided.

+Our Specifications

-7-

8 Company Profile 2011

+Enclosure: Metalpowder-coatedcabinetwith3/16inchtempered glassinsetondoor.MeetsNEMA12requirements.

Operating Temp: 32°to131°(0°to55°C).

Operating Humidity:5to90%RH,non-condensing.

Signal Outputs: 4-20mAanalogoutput(current) 4-20mAanalogoutput(voltage) 4-20mAanalogoutput(flowmeter) 4-20mAanalogoutput(copperanalyzer) Twodrycontactalarms(alarm1&alarm2)

Signal Inputs: 4-20mAanalogoutput(remotecontrol) 4-20mAanalogoutput(unassigned) 4-20mAanaloginput(flowmeter) 4-20mAanaloginput(copperanalyzer) FlowSwitch

Electrical Data: 120/240VAC,50/60Hz.,single-phase;factory configured.DCoutputvoltageforallmodelsis0-100 volts(self-adjusting).

Model   AC  Power   Current  Draw   DC  Output   Weight   Cabinet   Moun8ng  Holes  

S1000   120  VAC   16.0  amps   10.0  amps   58  lbs.   18.5  x  13.5  x  7.25”   14.75  x  14.75”  

240  VAC   8.0  amps   10.0  amps    

S750   120  VAC   16.0  amps   7.5  amps   58  lbs.   18.5  x  13.5  x  7.25”   14.75  x  14.75”  

240  VAC   8.0  amps   7.5  amps  

S500   120  VAC   8.0  amps   5.0  amps   55  lbs.   18.5  x  13.5  x  7.25”   14.75  x  14.75”  

240  VAC   4.0  amps   5.0  amps  

S300   120  VAC     8.0  amps   3.0  amps   51  lbs.   18.5  x  13.5  x  7.25”   14.75  x  14.75”  

240  VAC   4.0  amps   3.0  amps  

S150   120  VAC   3.0  amps   1.5  amps   24  lbs.   15.0  x  12.5  x  6.25”   11.25  x  13.75”  

240  VAC   1.5  amps   1.5  amps  

S100   120  VAC     3.0  amps   1.0  amps   24  lbs.   15.0  x  12.5  x  6.25”   11.25  x  13.75”  

240  VAC   1.5  amps   1.0  amps  

S50   120  VAC     3.0  amps   0.5  amps   24  lbs.   15.0  x  12.5  x  6.25”   11.25  x  13.75”  

240  VAC   1.5  amps   0.5  amps  

Legionella   Proven  track  record  with  over  1,200  installa6ons  over  15  years  

Effec6ve  against  bacteria;  however  does  not  provide  residual  protec6on  

Quick  &  effec6ve  in  the  suppression  of  bacteria  but  cannot  provide  residual  protec6on  

In  Vitro  studies  show  ability  to  kill  bacteria  while  ini6al  field  reports  cite  ineffec6ve  long  term  results  

Ini6ally  effec6ve;  however,  bacteria  quickly  redevelops  

Effec-ve  on  domes-c  cold  water  system  

Yes   Does  not  provide  residual  protec6on  

No   Yes   Yes  

Effec-ve  on  domes-c  hot  water  system  

Yes   Does  not  provide  residual  protec6on  

No   Dissipates  rapidly  at  warmer  water  temperatures  

Decomposes  at  elevated  water  temperatures  

Chemical   None   None   None   Chlorine  Dioxide  (Sodium  ChloriOe)  

Sodium  Hypochlorite  

By-­‐Products   None   None   None   Chlorite  &  Chlorate   Trihalomenthanes  (THM)  

Toxicity  &  Health  Effects  

None   None   Poten6al  scalding  problems  

CLO2  &  DBP’s  (Chlorite  &  Chlorate)  present  adverse  health  effects  

Known  harmful  by-­‐products  

pH  Sensi-ve   9+  pH   N/A   None   Unknown   7.8  pH  Max  Rendered  ineffec6ve  

EPA  Registered  or  Approved  

Yes   Yes   N/A   Yes   Yes  

Impact  on  Equipment  &  Systems  

None   None   Poten6al   Minimal  poten6al  corrosion  problems  

Presents  corrosion  problems  

Length  of  -me  to  control  Legionella  in  a  distribu-on  system  

Within  30  days   Has  not  shown  an  ability  to  gain  control  

Quick  results  but  must  be  repeated  

Control  may  not  be  obtained  for  an  excess  of  a  year  

Has  not  shown  an  ability  to  gain  control  

+

-9-

Product Comparision

10 Company Profile 2011

ThefollowingaresomeoftheworldclassfacilitiesthatarecurrentlyusingaLiquiTech®system.Shouldyouwishtospeakwiththesefacilitiesoranyofourotherclientspleasecontactourofficeandwewillprovideyouwithcompletecontactinformation.

Our Clients

Alice Hyde Memorial Hospital Malone,NewYork

Allina Health system | Mercy Hospital CoonRapids,Minnesota

Amsterdam Airport Dorint Sofitel TheNetherlands

Baycrest Centre Toronto,Ontario

Blossom View Nursing Home Sodus,NewYork

Billings Clinic Billings,Montana

Cox Health Systems Springfield,Missouri

Harborage Nursing Home NorthBergen,NewJersey

Hattenboer-Water TheNetherlands

Health Waikato Auckland,NewZealand

Jefferson Regional Medical CenterPittsburgh,Pennsylvania

Lakeridge Health System OshawaOntario,Canada

Memorial Sloan-Kettering Cancer Center NewYork,NewYork

Methodist Hospital SanAntonio,Texas

Millard Gates Medical CenterBuffalo,NewYork

Mount Sinai HospitalNewYork,NewYork

New York Presbyterian Weil Cornel New York,NewYork

North Shore UniversityEvanston,Illinois

Northwestern Memorial HospitalChicago,Illinois

Oak Forest HospitalOakForest,Illinois

Phelps Memorial Hospital Center Hollow,NewYork

Rockefeller CenterNewYork,NewYork

Rockview General HospitalAlberta,Canada

Seton Medical CenterDalyCity,California

Southeast Alabama Medical CenterDothan,Alabama

St. Elizabeth Medical CenterCovington,Kentucky

St. Joseph Hospital CenterSyracuse,NewYork

St. Joseph Medical CenterTowson,Maryland

St. Peter’s HospitalAlbany,NewYork

St. Vincent’s Medical CenterErie,Pennsylvania

Suny Upstate Medical CenterSyracuse,NewYork

University of Maryland Medical Center Baltimore,Maryland

University of Wisconsin Medical CenterMadison,Wisconsin

Wilford Hall Medical Center LacklandAirforceBaseinSanAntonio,Texas