Post on 16-Oct-2021
transcript
LRX™ FLY SWATTER ROTATOR
Check for the latest manual updates at www.dwightcrane.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
1
1
The LRX FLY SWATTER ROTATOR is intended to be used as an attachment for
telescopic fork lifts. This unit provides two axes of rotation; Pan (left / right) and
Tilt (up / down). This unit is powered by an onboard battery. It is advisable to
charge the unit when not in use. (U-Ground charger plug is located under rear
access door). Note: battery can’t be over charged. Average off charge, power on
standby: 24 hours usable. Recharge time is approximately five hours.
A light weight user designed and supplied truss structure mounts onto the
horizontal output shaft flanges. These flanges are designed to mate with twelve or
sixteen inch box truss trusses with end flanges that have a four bolt mounting
pattern with a bolt circle between 8.65”-10.45 BHC or 14.62"-16.22" BHC and a
bolt diameter of 0.75" or less.
The user constructed assembly provides mounting for a variety of fabric or
lighting options.
See notes for use, limitations and installation on to a telehandler
LRX™ FLY SWATTER ROTATOR
Check for the latest manual updates at www.dwightcrane.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
2
2
WARNING
READ EQUIPMENT MANUFACTURES
MANUAL BEFORE USING THIS PRODUCT
SAFETY INSTRUCTIONS
Fly Swatter Rotator weight: 1500 pounds.
Fly Swatter maximum load capacity evenly distributed.
Starter truss guide lines must be followed.
Up to 30’ x 30’ panel screen size = 1,400 lbs. weight of truss structure +
(0.89 PSF) 810 lbs. of wind loading (18.7 MPH / 30KPH)
Wind load formulas:
PSF=MPH2
x .00256
P (Pa) = KPH2
x 0.317
1 MPH = 1.61 KPH
1 KPH = 0.622 MPH
Ensure unit meets all local codes prior to operation.
Truss structure by others; to be approved by a professional engineer to safely
carry anticipated loads.
Fly Swatter, truss structure & wind loading calculations are the responsibility
of the user.
Ensure telehandler is capable of supporting the total load: Fly swatter, truss
structure and the wind load being applied.
Telehandler side loading: Maximum 3% of capacity chart or less if limited by
the telehandler OEM’s specs and instructions.
Load limits never to be exceeded.
Follow all telehandler manufactures guide lines and operating procedures.
It is the user’s responsibility and obligation to determine and comply with all
applicable laws and regulations.
Operator must stay with unit when in operation.
It is recommended to develop a truss recovery procedure with the telehandler
to set a position with minimum sail area.
It is recommended that a means to partially release the fabric be used to
relieve wind pressure on the structure in the event of unexpected wind gusts.
LRX™ FLY SWATTER ROTATOR
Check for the latest manual updates at www.dwightcrane.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
3
3
The installation, operation and servicing of this unit to be carried out only by
only authorized and qualified personnel certified in jurisdiction of use.
Daily pre-operational inspection and log required.
Do not operate if unit appears damaged, report damage immediately.
Activate mechanical E-stop when data signal is absent or in when unit is not
in use.
Electronic E-stop is automatically activated when data cable is removed or
damaged.
Activate mechanical E-stop when unit is in transit.
In case of malfunction activate hand controller electronic E-stop and
mechanical E-stop if accessible, discontinue use, notify supplier.
To reinstate operation, hold unlock and direction key, (electronic E-stop only).
Never operate with any covers removed.
No personal within range of motion during operation.
Area under Fly Swatter Assembly should be cordoned off at all times.
Observe pinch points.
No user serviceable parts.
DANGER
Dangerous voltages are present inside this unit.
Best practice electrical procedures must be followed when using this unit.
Ensure all power supplies are off when connecting or disconnecting any
cabling.
Power must be removed & switches returned to off position when not in use
and when data signal is removed.
Ensure unit meets all local codes prior to operation.
In case of emergency activate any E-Stop if safe to do so.
WARNING
This unit has rotating parts with pinch points.
Unit may move without warning.
No personnel are permitted within the range of motion
This unit is capable of developing 4,000 lb/ft. output torque which could create
a hazardous crushing force; serious injury or death may result.
In case of emergency activate any E-Stop if safe to do so.
Never operate with any covers missing.
LRX™ FLY SWATTER ROTATOR
Check for the latest manual updates at www.dwightcrane.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
4
4
Fly Swatter Rotator
Specifications
Electrical rating:
Internal gel-cells (48VDC)
Battery charger requires 120-240 VAC @ 2 amps (non-dimmed line).
It is advisable to charge the unit when not in use. (U-Ground charger plug is
located under rear access door). Note: battery can’t be over charged
Average off charge, power on standby 24 hours usable.
Recharge time is approximately five hours.
U-Ground charging lead must have a reliable earth conductor.
Physical:
Tilt: continuous (only limited by attached structure)
Pan: continuous (only limited by attached structure)
Weight: 1500 pounds approximate.
Dimensions: 48” x 33.61” x 56.42”
Output torque: Maximum 4,000 lb./ft. (electronically limited)
Fly Swatter maximum load capacity evenly distributed.
Starter truss guide lines must be followed.
Up to 30’ x 30’ panel screen size = 1,400 lbs. weight of truss structure + (0.89
PSF) 810 lbs. of wind loading (18.7 MPH / 30KPH)
Wind load formulas:
PSF=MPH2
x .00256
P (Pa) = KPH2
x 0.317
1 MPH = 1.61 KPH
1 KPH = 0.622 MPH
Also see Figure 1: Wind/Load Reference table.
LRX™ FLY SWATTER ROTATOR
Check for the latest manual updates at www.dwightcrane.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
5
5
Figure 1: Wind/Load Reference Table
LRX™ FLY SWATTER ROTATOR
Check for the latest manual updates at www.dwightcrane.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
6
6
OPERATING INSTRUCTIONS
Power Source:
Internal 48 VDC power supply (Gel Battery)
E-Stop buttons are located on each exterior side panel as well as the main
control panel. Switch any one of these to off when not in operation.
The hand controller indicates the battery status, the first operation post sleep /
at initial power up may take several seconds.
Unit will not operate when low battery is detected. Recharge time is
approximately five hours.
Emergency battery disconnects:
E-Stop buttons are located on each exterior side panel. Switch any one of these
to off when not in operation.
Electronic E-stop is automatically activated when data cable is removed or
damaged.
Electronic E-Stop can also be activated at the hand controller
Safety Interlock:
The Functions Enable/Unlock Keys (bottom of the hand control enable/unlock
key) needs to be held to enable motion.
If any other key is pressed without “FUNCTION ENABLE/UNLOCK” the display
will show “lck” (Locked).
Initiate Motion:
Hold either of the “FUNCTION ENABLE” keys, the display changes to “rdy” (ready).
Press the desired direction key (◄ ►▼▲) while still holding a “FUNCTION ENABLE” key –
[ post sleep / first power up may take several seconds to respond ].
Speed Control:
The rabbit & turtle buttons will increase and decrease drive speeds as required.
Sleep modes (when idle):
50 seconds to hand control sleep mode (blank display), press “FUNCTION
ENABLE” to wake the fixture.
.69
Typ
. 0
3.8
2
11.8
2
19.8
2
25.8
2
31.0
8
0
3.06 3.69 5.06 5.69 8.00
41.67
48.42
33.4
4
14.3
0 -
1
6.1
0 B
HC
8
.65
-
10
.45
BH
C
5.7
1
77.1
3
0
47.9
0
For
k p
ocket
open
ing
2.8
" X
7.0
" X
44" dee
p -
2 p
lcs
Acc
ess
doo
r: D
ata
por
t, m
anu
al&
bat
tery
ch
arge
r plu
g
E-S
top
E-S
top
Display Screen: when flashing indicates standby mode
Speed Control Buttons
Directional Control Buttons
Press & HOLD either of the "UNLOCK"buttons while pressing the a directional arrow button to move the Fly Swatter
Bar graph on right side of displayscreen shows applied motor torque when motor is energized
Emergency Stop Buttons
FLY SWATTER ROTATORHAND CONTROLLER
1.5
Ton
Sh
ackle
wit
h p
ins
capit
avte
d
3/8
" R
atch
et l
oad b
inder
3/8
" gr
ade
80 l
ifti
ng
chai
n
Insta
llation o
f Fly S
watter R
ota
tor to T
elehandler:
·Ensure forks a
re fully inserted
Secu
re F
ly S
watter to telehandler u
sin
g two 3
/8" g
rade 8
0 chain
s.
·One chain
is a
ttach
ed a
t tw
o d
ifferent poin
ts o
n the s
ame s
ide o
f th
e F
ly S
watter
usin
g 1
.5 ton b
olt type s
hack
les (bolts m
ust be capitivated).
Chain
must be r
outed s
o that th
e forks a
re lock
ed to the fork
carriage; remove a
dditional slack
and lock
into p
lace
usin
g the 3
/8"”r
atchet ty
pe load
bin
der.
Repeat for o
ther s
ide.
Ch
ain
rou
ted a
rou
nd &
secu
red t
o fo
rk c
arri
age
FLY
SWAT
TER
ROT
ATOR
Typ
ical
Sta
rter
Tru
ss A
ssem
bly
Tru
ss m
ust
cre
ate
a bo
x a
rou
nd t
he
Fly
Sw
atte
r R
otat
or.
Tru
ss s
tru
ctu
re b
y ot
her
s; t
o be
appro
ved b
y a
pro
fess
ion
al e
ngi
nee
r to
saf
ely
carr
y an
tici
pat
ed l
oads.
F
ly S
wat
ter,
tel
ehan
dle
r, t
russ
str
uct
ure
& w
ind l
oadin
g ca
lcu
lati
ons
are
the
resp
onsi
bili
ty o
f th
e u
ser.
96
7
2
96
72
16
72
72
48.0
0
32
.00
Max
.
Sixte
en I
nch
Alu
min
um
Box
Tru
ss
Sixte
en I
nch
Cu
be
Alu
min
um
Gra
pple
En
d P
late
Con
nec
tors
1.5
" Sc
hu
du
le 4
0 a
lum
inu
m p
ipe
wit
h c
onn
ecto
rs
FLY
SWAT
TER
ROT
ATOR
Typ
ical
Tru
ss C
onfi
gura
tion
Tru
ss m
ust
cre
ate
a bo
x a
rou
nd t
he
Fly
Sw
atte
r R
otat
or.
Tru
ss s
tru
ctu
re b
y ot
her
s; t
o be
appro
ved b
y a
pro
fess
ion
al e
ngi
nee
r to
saf
ely
carr
y an
tici
pat
ed l
oads.
F
ly S
wat
ter,
tel
ehan
dle
r, t
russ
str
uct
ure
& w
ind l
oadin
g ca
lcu
lati
ons
are
the
resp
onsi
bili
ty o
f th
e u