Post on 06-Mar-2018
transcript
2
Mallard Control
Mallard Model 5100 Freezeless Control (Dump) Valve
The model 5100 “freezeless” dump valve is perfectly suited for fluid control in oil and gas separators and other process vessels. The valve body
design allows the plug and seat to be constantly submerged in the process media, thus giving the valve its “freezeless” characteristic.
Features Compact valve size
Stainless steel trim
Threaded process connections
NACE MR0175 compliance option
SpecificationsProcess connections 1" MNPT x 1/2" FNPT 1" MNPT x 1" FNPT 2" MNPT x 1" FNPT
Body Style: “Freezeless” angle
Maximum operating pressure 2220 psig at 100 ˚F (38˚C)
Operating temperature range -40˚ to 200˚F (-40˚ to 93˚C)
Actuator Air supply connection: 1/4" FNPT Action: Reverse (fail close) Effective area: 35 sq. in. Maximum supply pressure 50 psig
Trim characteristic Quick opening (on/off)
Port diameter / Flow coefficient (Cv) 0.38"/4.8 Cv 0.50"/8.3 Cv
ContentsModel 5100 Freezeless Control (Dump) Valve
Features, Specifications, Part Number Codes & Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 - 3
Model 5126 & 5127 Freezeless Control (Dump) Valves
Features, Specifications, Part Number Codes & Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 - 5
Model 5300 3-Way Control Valve
Features, Specifications, Part Number Codes & Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 -7
Model 5400 Open Yoke & Model 5450 Close-Coupled Control (Dump) Valves
Features, Specifications, Part Number Codes, Dimensional Data & Engineering Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 -11
D-Series Control Valve
Features, Specifications, Part Number Codes, Dimensional Data & Engineering Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 -16
Model 3300 and 3350/3360 Pressure Controllers
Features, Specifications, Part Number Codes, & Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 - 19
3
Mallard Control
Mallard Model 5100 Freezeless Control (Dump) Valve
5100 - 5 S S 9 - R A B - 35
Body Size1 • 1" MNPT x 1" FNPT2 • 2" MNPT x 1" FNPT5 • 1" MNPT x 1/2" FNPT
Body ConnectionS • Threaded
Trim MaterialsS • Stainless Steel, .38" Orifice T • Stainless Steel, .50" OrificeN • Kynar, .38" OrificeP • Kynar, .50" Orifice
Valve Rating9 • 2220 psig (153 bar)
Actuator StyleR• Reverse (Fail Close)
Body StyleA • Angle
SealsB • Buna-NV • Viton®
N • NACE
Actuator Size35 • 35 Sq.In. (9.5" Dia.)
Example
Approximate Weight (lbs., kg)
Process Connection Weight
(lbs.) (kg) 1.00 MNPT x 0.50 FNPT 13.5 6.1 1.00 MNPT x 1.00 FNPT 14.5 6.6 2.00 MNPT x 1.00 FNPT 14.5 6.6
B
.66"
1.12"C
7.12"
9.50"
.25 NPT SUPPLY
A
Part Number Codes
Dimensional Data (in., mm) Body Size Dimension (in.) Dimension (mm) Code A (MNPT) B (FNPT) C A (MNPT) B (FNPT) C 1 1.00 1.00 0.75 25.4 25.4 19.1 2 2.00 1.00 0.75 50.8 25.4 19.1 5 1.00 0.50 0.63 25.4 12.7 16.0
Materials of Construction Description Material Liquid Chamber Carbon Steel (Std.) Cover Carbon Steel Body Low Temp Carbon Steel Plug 302 Stainless Steel
Seat
304 Stainless Steel Kynar (Opt.)
Valve Stem 303 Stainless Steel,
316 Stainless Steel (Opt.)
Seals Buna-N,
Viton® (Optional) Actuator Housing Steel
4
Mallard Control
Mallard Model 5126/5127 “Freezeless” Control (Dump) Valve
The model 5126/5127 "freezeless" dump valve is designed for fluid control in oil and gas separators and other process vessels. The valve
body design allows the plug and seat to be constantly submerged in the process media, thus giving the valve its "freezeless" characteristic.
Features Simple maintenance: Valve trim
or the complete actuator assembly can be quickly changed by simply removing the hammer nut and lifting the actuator assembly off the valve body. Disassembly of the actuator or removal of the valve from the line is not required. No special tools are required.
Simple installation: Compact, lightweight design enables quick, easy installation with minimal labor requirements.
Variety of valve trims: Available in stainless steel (standard) or tungsten carbide (optional) trim material, size 1/4", 3/8" or 1/2".
Bonnet safety pressure relief: Special design of hammer nut provides warning indication if an attempt is made to remove the actuator while the valve body is still under pressure.
Variety of actuators: The spring- opposed diaphragm actuator is available in adjustable and non-adjustable configurations for either reverse (fail close) or direct (fail open) acting applications.
Marine option: Makes this dump valve ideally suited for harsh marine environments where corrosion and salt build-up are a problem. A combination of stainless steel parts and special actuator preparation makes the “marine option” a valuable feature.
Materials of construction that comply with NACE MR0175 specifications are available upon request.
SpecificationsBody style: Angle
Process connections: 2" MNPT x 1" FNPT
Pressure rating: 1500 psig at 100 ˚F (38˚C)
Maximum differential pressure: 1500 psig
Assembled valve temperature range -40 to 200˚F (-40˚ to 93˚C)
ANSI leakage rating: Class IV
Flow Coefficients (Cv) Trim Trim Characteristic Size (in.) Quick Opening Mod. Percent 1/4 1.4 1.3 3/8 2.0 1.9 1/2 2.3 2.2
Approx. Weight w/Actuator (lbs., kg)
Actuator Size Weight
(lbs.) (kg) No. 35 25 11.3 No. 70 35 15.8
5
Mallard Control
Mallard Model 5126/5127 “Freezeless” Control (Dump) Valve
5126 -2 R 35 B - 1 2 Q
Threads26 • Internal & External Threads 27 • External Threads
Process Connection2 • 2" MNPT x 1" FNPT
Actuator TypeB • Direct Acting (Fail Open) Non-adjustableC • Reverse Acting (Fail Close) Non-adjustableD • Direct Acting (Fail Open) Adjustable (5126 Only)R • Reverse Acting (Fail Close) Adjustable
Actuator Size35 • No. 35 70 • No. 70
Seal MaterialB • Buna V • Viton®
Materials of Construction– • CS, Std. Service N • CS, NACE Option M • CS, Marine Option R • CS, Marine, NACE Options
Trim Material1 • 17-4PH SS (5126 Only) 3 • 316SS (5127 Only) 2 • Tungsten Carbide
Trim Size2 • 1/4" 3 • 3/8" 4 • 1/2"
Trim CharacteristicQ • Quick Opening (On/Off)M • Modified Percent (Throttling, 5126 Only)
Example
E
C
.250 NPTSupply
.250 NPTSupply
1.00FNPT
B
A
D
H
2.00MNPT
1.00 FNPT(5126 Only)
1.00FNPT
2.00MNPT
1.00 FNPT(5126 Only) Non-Adjustable Adjustable
G
CB
A
F
H
Part Number Codes
Materials of Construction Description Material
Valve Body Low Temp
Carbon Steel
Carbon Steel, Bonnet Electroless-Nickel Coated, Stainless Steel Hammer Nut Carbon Steel
Trim 17-4PH Stainless Steel, Tungsten Carbide (Opt.)
Valve Stem
303 Stainless Steel, 316 Stainless Steel (Opt.)
Packing PTFE V-Ring
Seals Buna,
Viton® (Opt.)
Diaphragm Steel Housings
Diaphragm
Buna Reinforced with Nylon Fabric Actuator Spring Steel
Dimensional Data (in., mm)
Model Dimension (in.)
A B C D Max. E Max. F Max. G Max. H 5126 3.00 2.88 5.88 13.5 19.38 9.25 15.13 9.5 5127 1.75 2.88 4.62 14.0 18.62 9.25 13.87 9.5 Dimension (mm ) 5126 76.20 731.15 149.35 342.9 492.25 234.95 384.3 241.3 5127 44.45 731.15 117.35 356.0 472.95 234.95 352.3 241.3
6
Mallard Control
Mallard Model 5300 3-Way Control Valve
The model 5300 is designed to withstand the severe service applications common to the oil and gas industry. It can be installed in converging (blender) or diverging
(diverter) flow configurations. The ease of maintenance and rugged steel construction make the model 5300 a perfect choice for a wide variety of 3-way valve applications.
Features Variety of end connections:
Available with female NPT threaded connections, or flanged connections from ANSI 150 to ANSI 1500. ANSI ratings above class 600 are available in either raised face (RF) or ring joint (RTJ) style flange facing.
Simple maintenance: Valve trim or the complete actuator assembly can be quickly changed by simply removing the hammer nut and lifting the actuator assembly off the valve body. Disassembly of the actuator or removing the valve from the line is not required. No special tools are required.
Valve trim is available in solid 316 stainless steel or 316 stainless steel with TFE plug inserts for positive shut-off.
Comes complete with a spring opposed diaphragm actuator which can be set up to fail to the lower or upper port.
SpecificationsBody style: 1"
End connections: FNPT
Available trim sizes 1" full port 3/4" x 3/8" blow case
Flow characteristic Quick opening (on/off)
Pressure rating 4000 psig at 100˚F (38˚C)
Assembled valve temperature range -20 to 200˚F (-29 to 93˚C)
Materials of Construction Description Material Valve Body Carbon Steel Bonnet Carbon Steel Hammer Nut Carbon Steel Seat /Cage 316 Stainless Steel Plug Solid 316 Stainless Steel Valve Stem 303 Stainless Steel Packing PTFE V-Ring
Seals
Buna-N, Viton® (Optional)
Actuator Housing Steel Diaphragm Nylon-Reinforced Nitrile Actuator Spring Steel
C U
L
C U
Blending Diverting
L
Max. Allowable Shutoff Pressure Drops Trim
Actuator Max. Press. Drop (psid)
Size 1" Valve Body (in.)
Size Diverting Blending
1 No. 35
800 400 3/4 x 3/8 1300 1300 1 No. 70 1000 800
Flow Coefficients (Cv) Trim Flow Flow Co. (Cv) Size (in.) Direction 1" Valve Body
1 C-U 9.0
C-L 12.5
3/4 x 3/8 C-U 7.7
C-L 3.2
7
Mallard Control
Mallard Model 5300 3-Way Control Valve
5300-1 S 5 - W 70 R B-3 A Q
Body Size1 • 1"
End Connections S • Female NPTF • Raised Face (RF) FlangeJ • Ring Type Joint (RTJ) Flange
ANSI Class (Pressure Rating)1 • ANSI 150 6 • ANSI 6003 • ANSI 300 9 • ANSI 9005 • ANSI 1500 FNPT Ends (4000 psi @ 200°F)
Materials of Construction– • WCC Steel, Standard ServiceN • WCC Steel, NACE MR0175
Body StyleW • 3-Way
Actuator Selection35 • Size 35 70 • Size 70
Actuator TypeD • Direct Acting (Fails to Lower Port)R • Reverse Acting (Fails to Upper Port)
Seal MaterialB • Buna-N V • Viton®
Trim Material3 • Solid 316 Stainless Steel
Trim SizeA • Full Port C • 3/4" x 3/8" Blow Case Trim
Trim CharacteristicQ • Quick Opening (On/Off)
Example
C
B
B
A
J1
D
E Dia.
D
E Dia.
FMax.
Part Number Codes
Diaphragm Effective Area & Housing Max. Pressure
Actuator Diaphragm Housing
Effective Max.
Size Area Pressure
No. 35 35 in.2 50 psig No. 70 70 in.2 35 psig
Valve & Actuator Dimensional Data (in., mm)
End Dimension (in.)
1" Valve Body
Connection A B C
NPT 6.25 3.12 4.62 150 RF 7.25 3.62 4.62 300 RF 7.75 3.88 4.62 600 RF/RTJ 8.25 4.12 4.62 900 RF/RTJ 9.38 4.69 4.62 1500 RF/RTJ 9.38 4.69 4.62 Dimension (mm) NPT 158.75 79.25 117.35 150 RF 184.15 91.95 117.35 300 RF 196.85 98.55 117.35 600 RF/RTJ 209.55 104.65 117.35 900 RF/RTJ 238.25 119.13 117.35 1500 RF/RTJ 238.25 119.13 117.35
Actuator
Dimension (in.) Direct Acting
Size
D E J1
No. 35 11.25 9.50 5.50 Size 70 13.75 12.50 7.00 Reverse Acting (in.) No. 35 9.25 9.50 11.25 Size 70 11.50 12.50 13.50 Dimension (mm) Direct Acting No. 35 285.75 241.3 139.7 Size 70 349.25 317.5 177.8 Reverse Acting (mm) No. 35 234.95 241.3 285.8 Size 70 292.10 317.5 342.9
1 Clearance required for spring removal.
8
Mallard Control
Mallard Open Yoke & Close-Coupled Control (Dump) Valves
Models 5400 open yoke and 5450 close-coupled control (dump) valves are designed to meet the high pressure and erosive applications common to the oil and gas industry. These valves are ideally suited for pressure, level, temperature, and flow control applications on
separators, scrubbers, wellheads and other oilfield equipment. The ease of maintenance, rugged steel construction, flexibility to meet a wide variety of applications, and safety features make models 5400/5450 control valves the preferred choice of production operators worldwide.
Features Simple maintenance: Valve trim
or the complete actuator assembly can be quickly changed by simply removing the hammer nut and lifting the actuator assembly off the valve body. Disassembly of the actuator or removing the valve from the line is not required. No special tools are required.
Compact, lightweight design enables quick, easy installation with minimum labor requirements.
Bonnet safety pressure relief: Special design of hammer nut provides warning indication if an attempt is made to remove the actuator while the valve body is still under pressure.
Hardened trim: Control valve trim is available in stainless steel or tungsten carbide to handle the most difficult applications.
Bi-directional flow: Valve can be installed for either “flow up” or “flow down” operation, whichever best suits the application.
Marine and/or sour gas service option: For harsh marine environments where corrosion and salt build-up are a problem, select “marine service” material option in the valve’s model code. Ideal for offshore or coastal production facilities. For sour gas applications, materials are available that comply with NACE MR0175 specifications.
SpecificationsAvailable configurations Open yoke (model 5400) Fail-open or fail-close Close-coupled (model 5450) Fail-open or fail-close
Flow characteristic Modified percent (throttling) Quick opening (on/off)
Body styles Globe (1" & 2"), angle (2" only) & tee (1" only)
End connections FNPT, flanged, socket weld & butt weldPressure ratings 4000 psig from -40 to 200˚F (-40 to 93˚C) 3540 psig at 500˚F (260˚C)Assembled valve temperature range Model 5400: -40 to 500˚F (-40 to 260˚C) Model 5450: -40 to 200˚F (-40 to 93˚C)Available trim sizes: 1/4", 3/8", 1/2", 3/4" & 1"Shutoff classification: ANSI class IV(Stainless steel or tungsten carbide trim)
Flow direction Either direction, to suit the application Flow up (under the seat) recommended for throttling applications
Air pressure to actuator 3-15 spring 0 to 20 psig control signal recommended 6-30 spring 0 to 35 psig control signal recommended
Model 5450w/ tee body
Model 5400w/globe body
9
Mallard Control
Model 5400/5450 Open Yoke & Close-Coupled Control (Dump) Valves
5450-2 S 5 - G 73 R B-1 4 Q
Style00 • Open Yoke50 • Close-Coupled
Body Size1 • 1"2 • 2"
End ConnectionsS • Female NPTF • Raised Face (RF) FlangeJ • Ring Type Joint (RTJ) FlangeW • Socket WeldB • Butt Weld
ANSI Class (Pressure Rating)1 • ANSI 1503 • ANSI 3006 • ANSI 6009 • ANSI 9005 • ANSI 1500 FNPT, SW, BW Ends, 4000 psig at 200°F (93˚C)
Materials of Construction– • Carbon Steel, Standard ServiceM • Carbon Steel, Marine ServiceN • Carbon Steel, NACE MR0175 P • Carbon Steel, Marine Service and NACE MR0175H • Hi-TempT • Hi-Temp NACEL • Low-TempC • Low-Temp NACE
Body StyleG • Globe P • Globe w/Tapped Pressure PortsT • Tee (1") or Angle (2")
Actuator Selection33 • No. 35 Act. w/3-15 Spring 73 • No. 70 Act. w/3-15 Spring36 • No. 35 Act. w/6-30 Spring 76 • No. 70 Act. w/6-30 Spring
Actuator TypeR • Reverse Acting (Spring Closes / Air Opens) D • Direct Acting (Spring Opens / Air Closes)
Seal MaterialA • Aflas® L • Low-Temp Nitrile B • Buna-N R • HNBR E • EPDM V • Viton®
K • Kalrez® Y • Viton® GLT (Low-Temp)
Trim Material 1 • 17-4PH SST2 • Tungsten Carbide
Trim Size2 • 1/4" 4 • 1/2" 8 • 1"3 • 3/8" 6 • 3/4"
Trim CharacteristicM • Modified Percent (Throttling) Q • Quick Opening (On/Off)
Example
Part Number Codes
10
Mallard Control
C
B
A
1" & 2" Globe Body 1" Tee Body
2" Angle Body
G
HH
G
H
H
DF
Max.
E Dia.
5400 /5450Reverse Acting(5400 Shown)
5400 /5450 Direct Acting(5450 Shown) D
J
E Dia.
Note: Clearance Required for Spring Cover Removal
DF
Max.
E Dia.
5400 / 5450 Direct Acting
5400/ 5450 Reverse Acting
E Dia.
D
J
D
J
E Dia.
DF
Max.
E Dia.
Note: Clearance Required for Spring
Cover Removal
Model 5400/5450 Open Yoke & Close-Coupled Control (Dump) Valves
Approximate Weights (lbs., kg) Model 5400 / Weights (lbs., kg) End No. 35 Actuator No. 70 Actuator Connection 1" Globe 1" Tee 2" Globe 2" Angle 1" Globe 1" Tee 2" Globe 2" Angle lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg NPT 29 13.2 32 14.5 36 16.3 36 16.3 44 20.0 47 21.3 51 23.1 51 23.1 ANSI 150 34 15.4 38 17.2 46 20.9 46 20.9 49 22.2 53 24.0 61 27.7 61 27.7 ANSI 300 37 16.8 41 18.6 50 22.7 50 22.7 52 23.6 56 25.4 65 29.5 65 29.5 ANSI 600 39 17.7 43 19.5 52 23.6 52 23.6 54 24.5 58 26.3 67 30.4 67 30.4 ANSI 900/1500 46 20.9 51 23.1 80 36.3 80 36.3 61 27.7 66 29.9 95 43.1 95 43.1 Model 5450 / Weights (lbs., kg) NPT 25 11.3 28 12.7 32 14.5 32 14.5 40 18.1 43 19.6 47 21.3 47 21.3 ANSI 150 30 13.6 34 15.4 42 19.1 42 19.1 45 20.4 49 22.2 57 25.9 57 25.9 ANSI 300 33 15.0 37 16.8 46 20.9 46 20.9 48 21.8 52 23.6 61 27.7 61 27.7 ANSI 600 35 15.9 39 17.7 48 21.8 48 21.8 50 22.7 54 24.5 63 28.6 63 28.6 ANSI 900/1500 42 19.1 47 21.3 76 34.5 76 34.5 57 25.9 62 28.1 91 41.3 91 41.3
Actuator
Dimension (in.) 5400 Direct 5400 Reverse 5450 Direct 5450 Reverse
Size D E J1 D E F D E J1 D E F
No. 35 17.06 9.50 5.50 14.31 9.50 16.31 11.44 9.50 5.50 8.69 9.50 10.69 No. 70 18.56 12.50 7.00 15.44 12.50 17.44 12.94 12.50 7.00 9.81 12.50 11.81 Dimension (mm) No. 35 433.3 241.3 139.7 363.5 241.3 414.3 290.6 241.3 139.7 220.7 241.3 271.5 No. 70 471.4 317.5 177.8 392.2 317.5 443.0 328.7 317.5 177.8 249.2 317.5 300.0
1Clearance required for spring removal.
Valve & Actuator Dimensional Data (in., mm)
End Dimension (in.)
1" Globe Body 2" Globe Body 1" Tee Body 2" Angle Body
Connection A B C A B C G H G H
NPT 6.25 1.56 3.69 7.50 1.69 3.69 6.82 3.13 7.44 3.75 150RF 7.25 1.56 3.69 10.00 1.69 3.69 7.32 3.63 8.69 5.00 300RF 7.75 1.56 3.69 10.50 1.69 3.69 7.57 3.88 8.94 5.25 600RF 8.25 1.56 3.69 11.25 1.69 3.69 7.82 4.13 9.31 5.63 600RTJ 8.25 1.56 3.69 11.38 1.69 3.69 7.82 4.13 9.38 5.69 900/1500RF 9.38 1.56 3.69 12.88 1.69 3.69 8.38 4.69 10.13 6.44 900/1500 RTJ 9.38 1.56 3.69 13.00 1.69 3.69 8.38 4.69 10.19 6.50 Dimension (mm) NPT 158.8 39.6 93.7 190.5 42.9 93.7 173.2 79.5 189.0 95.3 150RF 184.2 39.6 93.7 254.0 42.9 93.7 185.9 92.2 220.7 127.0 300RF 196.9 39.6 93.7 266.7 42.9 93.7 192.3 98.6 227.1 133.4 600RF 209.6 39.6 93.7 285.8 42.9 93.7 198.6 104.9 236.5 143.0 600RTJ 209.6 39.6 93.7 289.1 42.9 93.7 198.6 104.9 238.3 144.5 900/1500RF 238.3 39.6 93.7 327.2 42.9 93.7 212.9 119.1 257.3 163.6 900/1500 RTJ 238.3 39.6 93.7 330.2 42.9 93.7 212.9 119.1 258.8 165.1
Diaphragm Effective Area & Housing Max. Pressure
Actuator Diaphragm Housing
Size
Effective Max. Area Pressure
No. 35 35 in.2 50 psig No. 70 70 in.2 35 psig
11
Mallard Control
Model 5400/5450 Open Yoke & Close-Coupled Control (Dump) Valves
Flow Coefficients (Cv), Modified Percent & Quick Opening
Body Orifice Body Style / Valve Opening (% Travel)
Size Size
Modified Percent Quick Opening
(in.) (in.) Globe Angle Globe Angle
10 20 30 40 50 60 70 80 90 100 100 100 100 0.25 .284 .506 .657 .767 .875 .989 1.10 1.20 1.32 1.40 1.64 1.68 1.92 0.38 .311 .621 .942 1.28 1.64 2.07 2.51 2.93 3.35 3.70 4.23 3.82 4.34 1 0.50 .502 1.05 1.59 2.09 2.61 3.14 3.72 4.27 4.96 5.62 6.61 5.70 6.72 0.75 .882 1.76 2.76 3.82 4.93 6.17 7.49 8.85 10.0 11.0 15.1 11.6 15.2 1.00 1.01 2.02 3.44 5.07 6.78 8.42 10.3 12.4 14.3 15.4 20.8 15.5 20.9 0.25 .284 .506 .657 .767 .875 .989 1.10 1.20 1.32 1.40 1.66 1.68 1.98 0.38 .311 .621 .942 1.28 1.64 2.07 2.51 2.93 3.35 3.70 4.35 3.82 4.47 2 0.50 .592 1.17 1.76 2.34 2.95 3.70 4.57 5.50 5.95 6.08 6.90 6.19 7.00 0.75 .882 1.81 2.98 4.11 5.74 7.03 8.49 10.1 11.5 12.9 15.2 13.0 15.8 1.00 1.08 2.12 3.58 5.43 7.46 9.27 11.4 13.7 15.8 17.1 21.1 18.0 22.0
Bonnet Safety Pressure ReliefThe valve on the left shows the hammer nut in the “locked” position during normal operation. The valve on the right illustrates “Bonnet Safety Pressure Relief”. The O-Ring clears the packing plug while the hammer nut is still engaged (threaded) onto the valve body. At this point, if the valve assembly is under pressure, process fluid will escape through the weep hole to indicate a warning to the service person that the valve is still under pressure, thereby prompting him to remove line pressure before proceeding, thus preventing the actuator assembly from blowing out.
Actuator Maximum Allowable Shutoff Pressure Drops, Reverse Acting (Fail Close)
Trim Flow Signal to No. 35 Actuator Signal to No. 70 Actuator
Size (in.) Direction
3 -15 Spring 6 - 30 Spring 3 -15 Spring 6 - 30 Spring
3 -15 psig 0 - 20 psig 6 - 30 psig 0 - 35 psig 3 -15 psig 0 - 20 psig 6 - 30 psig 0 - 35 psig
.25 3800 4000 4000 4000 4000 4000 4000 4000 .38 2050 3280 3410 4000 3210 4000 4000 4000 .50 Up 1100 1680 1830 2300 1650 3190 4000 4000 .75 320 560 690 950 530 940 2020 2800 1 110 220 320 490 230 420 960 1460 .25 4000 4000 4000 4000 4000 4000 4000 4000 .38 4000 4000 4000 4000 4000 4000 4000 4000 .50 Down 3350 4000 4000 4000 4000 4000 4000 4000 .75 1580 2300 2530 3270 2080 2800 3780 4000 1 770 1100 1240 1680 970 1460 2510 2950
Actuator Maximum Allowable Shutoff Pressure Drops, Direct Acting (Fail Open) Trim Flow Signal to No. 35 Act.1 Signal to No. 70 Act.1 Flow Signal to No. 35 Act.1 Signal to No. 70 Act.1
Size (in.) Direction 3 -15 Spring 6-30 Spring 3 -15 Spring 6-30 Spring Direction 3 -15 Spring 6-30 Spring 3 -15 Spring 6-30 Spring
.25 4000 4000 4000 4000 4000 4000 4000 4000 .38 2700 4000 4000 4000 4000 4000 4000 4000 .50 Up 1370 2880 2540 4000 Down 3800 4000 4000 4000 .75 410 1080 730 2020 1750 1940 4000 4000 1 140 520 230 960 860 940 1840 2790 1Actual signal pressure to actuator includes an additional 5 psig (0.3 bar) of supply pressure to the controller.
12
Mallard Control
Mallard D-Series Control Valve
The D-Series from Circor is the next generation of the reliable and proven control valve. The D-Series is an all purpose cage-guided, balanced control valve. This new product offers simplicity of design in a valve platform that is well suited for the needs of power, process and general industry.
A wider selection of valve sizes, materials and noise /cavitation trims allows application across a broader range of flow rates, pressures and temperatures.
SpecificationsBody style Single seated top entry threaded/bolted bonnet, globe style body, cage guided balanced plugSize, ratings and end connections 2" thru 8", Class 150, 300, 600, 900, 1500 RF, RTJ, BWE and SWE & NPT (in 2" only) 10" thru 16", Class 150, 300, 600 RF, BWE, RTJBody/bonnet materials Carbon steel, A216 Gr. WCC -20 to 800˚F (-29˚C to 427˚C) Low temp. carbon steel, A352 Gr. LCC -50 to 800˚F (-46˚ C to 427˚C) 316 stainless steel, A351 Gr. CF8M -50 to 1000˚F (-46˚C to 538˚C) Chrome-Moly steel, A217 Gr. WC9 -20 to 1000˚F (-29˚C to 538˚C)Stem packing Braided PTFE with Kevlar® filaments -20.2˚F (-29˚C to 230˚C) Graphite-2 anti-extrusion ring Grafoil®
-20.2˚F to 1050.8˚F (-29˚C to 566˚C)Gaskets: Body/bonnet and seat ring/body Spiral wound 316L /graphite 500˚F (260˚C) maximum Flexible graphite 1000˚F (538˚C) maximumTrim sizes: Full port, 80%, 60% and 40% reduced portPlug (piston) seal materials C300 spring loaded seal with Inconel® spring-up to 572˚F (300˚C) Class IV or V Double carbon-graphite seal rings up to 1000˚F (538˚C) Class IVFlow characteristics Equal percentage, linear with 1 and 2 stage noise and cavitation control
Shutoff class (FCI/ 70-2) Standard trim -20˚ to 572˚F (-18 to 300˚C) = Class V to 800˚F (427˚C) = Class IV High temp. trim to 1000˚F (538˚C) = Class IVActuators Standard: Multi-Spring and Diaphragm Optional: Piston, Double Acting/Spring Return Hydraulic Electric Electro-Hydraulic
Features Standard valve trim consists of
heat-treated, hardened 400 series SS, providing max. hardness with excellent wear properties. In addition, 316SS is offered for superior corrosion resistance. Seating surfaces can be additionally armored with nickel/cobalt overlay (Stellite®) on 316SS trims.
The balanced plug design equalizes line pressure under the plug with pressure above the plug, effectively cancelling any unbalanced stem force due to pressure drop. In addition to providing smooth high-pressure control, balanced plugs allow use of smaller, lighter, cost effective actuators. Class IV or V shut-off is provided.
D-Series heavy cupwasher style PTFE plug seal has 3x the cross- sectional area/wear surface of competing designs with minimal friction for tightest resolution. Pressure energized to provide a tight seal at low and high pressures and tight shut-off for longer than competitive designs.
Clamped in place with a simple and reliable yoke lock nut, D-Series actuator mounting guarantees ease of disassembly no matter how corrosive the environment.
D-Series control valves are specifically designed for high pressure drop service. Pressure drop, high velocities and throttling occur only at the cage window and the plug, thereby protecting the seat ring and tight shut-off capability of the valve.
13
Mallard Control
Mallard D-Series Part Number Codes
M A 1 1 A 1 A A 1 A0 A C E CE
Class • M
Body StyleA • Globe WCCB • Globe WC9
Valve Size1 • 2"2 • 2 1/2"
Valve Rating0 • ANSI 150
End ConnectionA • RF FlangeB • RTJC • BW 40
Bonnet & Packing1 • Std.-PTFE2 • Std.-Graphite
Trim MaterialA • Std. 410SS w/C300 Spring Loaded Seal B • 316SS w/C300 Spring Loaded SealC • 316SS/Stellite® w/C300 Spring Loaded SealD • Std. 410SS w/Graphite SealE • 316SS w/Graphite Seal
Cage TypeA • Standard -LIN (Flow over seat)B • Standard-EQ% (Flow over seat)C • Les -Cav I (Flow over seat)
Rated Cv1 • 100%
Actuator Type*A0 • M42-DA1 • M42-RA2 • M82-D
Actuator SpringA • 3 -15 (B6-2G)B • 12 - 45 (B6 - 6G)C • 12- 40 (A6- 6G)D • 4 -20 (C6 -3G)E • 10 - 45 (C6 -7G)
Leakage Class4 • Class IV
Accessories**A • 760P (Only)B • 760E (Only)
ComplianceBlank • None
Example
E • Angle WCCF • Angle LCC
D • BW 60E • BW 80F • BW x S
G • BW x XSH • SW 40I • SW 60
D • Les -Cav II (Flow over seat)E • Les -Sonic I (Flow under seat)F • Les -Sonic II (Flow under seat)
J • SW 80K • SW x SL • SW x XS
M • SW x XXSN • ThreadedX • Other
8 • 80% 6 • 60% 4 • 40%
A3 • M82-RA4 • M155-DA5 • M155-R
B0 • M42-D-HODB1 • M42-R-HODB2 • M82-D-HOD
B3 • M82-R-HODB4 • M155 -D-HODB5 • M155 -R-HOD
C • Globe CF8MD • Globe LCC
G • Angle CF8MH • Angle LCC
5 • Ext. PTFE6 • Ext. Graphite
3 • Std.-Dbl. PTFE4 • Std.-Dbl. Graphite
7 • Ext. Dbl. PTFE8 • Ext. Dbl. Graphite
3 • ANSI 300 6 • ANSI 600 9 • ANSI 900 1 • ANSI 1500
3 • 3"4 • 4"
5 • 6"6 • 8"
7 • 10"8 • 12"
9 • 16"
G • 10 -30 (B6 -3D) H • 17-50 (B6 -5D)J • 23 -70 (B6 -7D)K • 12-30 (C6 -3D)L • 20 -50 (C6 -7D)
5 • Class V
C • PS2 (Only)D • 760P + ASG-1
M • 28 - 68 (C6 -7D)N • 3 -15 psig (piston)X • NoneZ • See Order
E • 760E + ASG-1F • PS2 + ASG-1
CE • CE Certification NE • NACE
*Actuator type is specific to service conditions. Code provided from Circor Select®
**Additional accessories available. Contact factory for part numbers.
760P = Pneumatic Positioner (FM/CSA /ATEX/CE, No limit switches, no feedback, SGL /double acting, 1/2"-4" STK)760E = Electro-Pneumatic Positioner (EEX ia,FM/CSA /ATEX/CE, No limit switches, no feedback, SGL /double acting, 1/2"-4" STK)PS2 = SMART Positioner (EEx ia/ib, CENELEC/ATEX/FM/CSA, No limit switches, no feedback, double acting, 1.3"- 5" STK) ASG-1 = Air Set Regulator (0-100 psig)
F • 316SS/Stellite® w/Graphite SealG • CA6NM w/Graphite Seal (HT)H • 316SS/Stellite® w/Graphite SealN • NACE (316SS) w/C300 Spring Loaded Seal
14
Mallard Control
Spring & Diaphragm ActuatorThe D-Series is available with a multi-spring diaphragm actuator which delivers excellent control performance in a compact package. This actuator design is based on decades of proven and highly reliable diaphragm technology. The spring and diaphragm actuator provides for inherent fail safe operation and can be easily reversed between direct and reverse acting function. Standard positioners and a variety of accessories cleanly mount on this actuator.
Mallard D-Series Control Valve
Standard CageThe full ported, standard cage, provides maximum flow with minimum pressure drop. The inherent linear or equal percent flow characteristic provides excellent low flow control, high rangeability and maximum Cv per inch.
Anti-Cavitation CageThe Les-Cav cage controls the effects of valve cavitation providing a normal valve/trim life expectancy in cavitating conditions. Diametrically opposed holes, increase the valves cavitation index (Kc) and direct impinging flow to the center of the cage, preventing mechanical trim/body damage.
Reduced Trim CageThis optional cage reduces the maximum Cv and flow to 80%, 60% or 40% of the normal full port valve. Used to provide body velocity control, future flow expandability, or to correct for oversized valve conditions.
Noise Reducing CageThe Les-Sonic cage is designed to reduce fluid generatednoise up to 15-20dBA in steam, gas or any compressible fluid service. When used in conjunction with a Les-Sonic silencing orifice, noise attenuation of greater than 20dBA can be achieved.
Actuator Offerings
Compact multi-spring actuator is field reversible. Can install anywhere from 2 to 7 springs depending on thrust requirements.
Standard D-Series AccessoriesPositioners Pneumatic: Siemens model 760P Electropneumatic: Siemens model 760E, Siemens model PS2 Optional internal limit switches Optional valve positions transmissionProcess controllers Pneumatic: PDAP/PRAP, Mallard model 3350/3360 Electropneumatic: PMC-2Solenoid valves: ASCO 8320G174Noise reduction devices Noise suppressor Les-Sonic silencing orificeAir regulators: ASG-1, AFG-2
15
Mallard Control
Mallard D-Series Dimensions & Weights
Actuator Dimensional Data (in., mm) Size M42 (ST 6135) M82 (ST 6160) M155 (ST 6175) (in.) Stroke 1.4" Stroke 1.6" Stroke 2.4" Stroke 2.4" Stroke 4" 2 14.8 16.0 16.8 19.2 TBD 3 — — 14.5 19.2 TBD 4 — — 14.5 19.2 TBD 8 — — — — 26.6 10 — — — — 26.6 12 — — — — 26.6 16 — — — — 26.6 Weight (lbs.) 11 27.5 33 122 165 Dimensions (mm) 2 376 406 426 489 TBD 3 — — 446 489 TBD 4 — — 446 489 TBD 8 — — — — 675 10 — — — — 675 12 — — — — 675 16 — — — — 675 Weight (kg) 5 12.5 15 55 75
Dimensional Data (in., mm), 2" - 8", Class 150 -1500
Dimensional Data (in., mm), 10" - 16", Class 150 - 600 Size A (Raised Face) B C (in.) 150 300 600 150 300 600 150 -300 600 10 26.5 27.9 29.6 9.7 9.3 22.7 23 12 29 30.5 32.2 10.8 23.9 24.0 16 40 41.6 43.6 13.2 13.6 13.8 23.5 Dimensions (mm) 10 673 708 752 254 235 576 586 12 737 775 819 270 605 611 16 1016 1057 1108 334 344.5 350 599
A
C
B
D
A
C
B
D
Size Thread A (Raised Face) B C (in.) NPT 150 300 600 900 1500 150 300 600 900 1500 150 -1500 2 11.26 10.0 10.51 11.26 14.76 14.76 2.76 2.76 2.76 2.87 2.87 8.84 3 — 11.732 12.52 13.27 17.36 18.11 3.54 3.54 3.54 30.54 3.77 11.14 4 — 13.86 14.49 15.51 20.11 20.86 3.94 3.94 3.94 4.64 5.31 11.89 6 — 17.76 18.62 20.0 28.11 30.23 5.91 5.91 5.91 6.77 7.28 14.10 8 — 21.34 22.36 24.02 35.98 38.26 7.60 7.60 7.60 8.66 9.50 16.78 Dimensions (mm) 2 286.0 254 267 286 375 375 70 70 70 73 73 224.5 3 — 298 318 337 441 460 90 90 90 90 96 283 4 — 352 368 394 511 530 100 100 100 118 135 302 6 — 451 473 508 714 768 150 150 150 172 185 358 8 — 543 568 610 914 972 193 193 193 220 241 426
Note: NPT available in 2" only.
16
Mallard Control
Weights (lbs., kg) Size Thread Raised Face Body Ring Type Joint Body Butt Weld End Body (in.) NPT 150 300 600 900 1500 150 300 600 900 1500 150 300 600 900 1500 2 50.7 50.7 58.2 61.7 119 119 51.6 59.5 62.2 120.2 120.2 51.4 86.6 3 — 105.4 117.3 123 204.2 243.6 107.6 120.6 124.1 205.7 245.8 98.3 185.2 4 — 158.7 176.4 201.7 33.75 403 161.6 182.3 202.6 335.5 405.4 148.2 316.1 6 — 275.6 326.3 395.1 577.4 843.9 277.8 332.6 397 578.7 848.1 298.7 647.5 8 — 553.8 603.6 816.8 1021.6 1469.4 558.2 612.9 820.1 1026.3 1480.2 704.8 1015 10 — 683 877 1281 — — 690 888 1285 — — 807 — 1049 — 12 — 1032 1327 1847 — — 1043 1343 1852 — — 1199 — 1572 — 16 — 1656 2277 3084 — — 1669 2299 3093 — — 2044 — 2635 — Weights (kg) 2 23 23 26.4 28 54 54 23.4 27 28.2 54.5 54.5 23.3 39.3 3 — 47.8 53.2 55.8 92.6 110.5 48.8 54.7 56.3 93.3 111.5 44.6 84 4 — 72 80 91.5 151.4 182.8 73.3 82.7 91.9 152.2 183.9 67.2 143.4 6 — 125 148 179.2 261.9 382.8 126 150.9 180.1 262.5 384.7 135.5 293.7 8 — 251.2 273.8 370.5 463.4 666.5 253.2 278 372 465.5 671.4 319.7 460.4 10 — 310 398 581 — — 313 403 583 — — 366 — 476 — 12 — 468 602 838 — — 473 609 840 — — 544 — 713 — 16 — 751 1033 1399 — — 757 1043 1403 — — 927 — 1195 —
Note: NPT available in 2" only. Weights are approximate. Weights are only for body sub-assembly.
Flow Coefficients (Cv) Size
DN Rating
Full EQ% 60% EQ% Full Linear 60% Linear Les-Sonic I Les Cav I
Les-Sonic II Les Cav II
(in.) Single Stage Single Stage 2 50 150 -1500 68 41 75 45 68 84 42 TBD 3 80 150 -1500 140 84 155 93 135 152 129 TBD 4 100 150 -1500 216 130 240 144 208 193 177 TBD 6 150 150 -1500 400 240 450 270 366 406 253 TBD
8 200 150-600 756 454 800 480 698 578 394 TBD
8 200 900-1500 680 408 720 432 712 502 348 TBD 10 250 150-600 1100 660 1300 780 997 953 647 TBD 12 300 150-600 1440 864 1800 1080 1114 1095 788 TBD 16 400 150-600 2300 1380 3100 1860 2322 1749 1155 TBD
Mallard D-Series Engineering Data
17
Mallard Control
Mallard Model 3300 and 3350/3360 Pressure Controllers
The model 3300 pressure controller used in conjunction with a control valve make up a complete control loop, which reacts automatically to
changes occurring in a process and provides precise control within a set range.
Features Wide Range of Bourdon Tubes:
Pressure ranges from 0-30 psig to 0-5000 psig are available. Two interchangeable ranges of output bellows and gauges, 3-15 psi and 6-30 psi, are also available.
Simple Adjustments: High-visibility dials are provided to assure accuracy of pressure setpoint, proportional band and reset settings.
Easy Maintenance: Simple controller design allows fast, easy maintenance and minimal spare parts inventory.
Field Reversible: Controller action can be switched with a few simple steps. No additional parts required.
Easy Mode Conversion: Add reset action to a proportional controller by simply adding a single module and three pieces of tubing.
Flexible Mounting Options: Available with brackets for mounting on actuator yoke, diaphragm housing, panel surface or 2" pipestand.
Vibration Resistance: Simple design and low mass of internal parts allow the controller to withstand vibration encountered in most industrial environments.
Low Air (Gas) Consumption: Relay and nozzle design reduces steady-state air (gas) consumption to as low as 4.2 scfh, cutting operating costs.
Sour Service Capability: Materials are available for applications handling sour gasses. These constructions comply with NACE MR0175 recommendations.
Model 3300Pressure Controller
The model 3350 /3360 design is preferred by production operators and technicians worldwide for pressure control requirements, due to its simple construction, versatility
and reliable performance in the most demanding applications. The controller is offered in proportional (model 3350) and proportional-plus-reset (model 3360) configurations.
Model 3350/3360Pressure Controller
18
Mallard Control
Mallard Model 3300 and 3350/3360 Pressure Controllers
Specifications,Pressure ControllersMaximum working pressure Same as bourdon tube rating
Input, supply & output connections 1/4" FNPT
Controller output signal 3-15 psig, 6-30 psig
Mounting Actuator yoke, actuator housing, Panel & 2" pipestand
Normal operating supply pressure 3-15 psig output: 20 psig 6-30 psig output: 35 psig
Maximum allowable supply pressure 3-15 psig output: 40 psig 6-30 psig output: 40 psig
Note: If the supply gas is flammable or noxious, the controller must be located in a well ventilated, non-hazardous area. If supply pressure is exceeded, control performance may be impaired.
Supply pressure requirements Clean dry air or non-corrosive gas
Options NACE MR0175 compliance for H2S service
Model 3300Input signal (bourdon tube ranges) 0 - 50 psig 0 - 1000 psig 0 - 100 psig 0 - 1500 psig 0 - 250 psig 0 - 2500 psig 0 - 500 psig 0 - 5000 psig
Setpoint adjustment Internal manual adjusting knob
Controller mode Proportional
Steady-state Air (gas) consumption 20 psig Supply: 35 scfh 35 psig Supply: 50 scfh
Model 3350/3360Controller configurations Proportional: Model 3350 Proportional -plus-reset: Model 3360
Input signal (bourdon tube ranges) 0-30 psig 0-600 psig 0- 60 psig 0-1000 psig 0-100 psig 0-1500 psig 0 -200 psig 0-3000 psig 0-300 psig
Steady-state Air (gas) consumption Minimum (proportional band setting of 0 or 10) 3 -15 psig output: 4.2 scfh 6-30 psig output: 7 scfh
Maximum (proportional band setting of 5) 3-15 psig output: 27 scfh 6-30 psig output: 42 scfh
Performance Repeatability: 0.5% of bourdon tube range Deadband: 0.1% of output span
Controller tuning adjustment ranges Proportional - full output
Pressure change 3-15 psig output: 6 -100% of input range 6-30 psig output: 6 -100% of input range
Reset: Adjustable from 0.01 to 74 Minutes per repeat (100-0.01 repeats per minute)
7.05"
8.01" Estimated Shipping Weight 11 lbs.
7.85"
5.57"0.69"
4.00" 3.95"
4.36"
3.85"
8.74" 7.98"
7.05"
8.01"
Estimated Shipping Weight 11 lbs.
5.57"
7.85"
0.69"
4.00"4.13"
4.13"
1/4" NPT
1/4" NPT
3.95"
4.36"
3.85"
8.74" 7.98"
1/4" NPT
1/4" NPT
Mallard Model 3300
9.38"
Estimated Shipping Weight 13 lbs.
Back View
Panel Cutout Dimensions for Panel Mounting 2.50
1/4" NPT
9.50"
Ø2.38"
Right Side View Pipestand Mounting
Flush PanelMounting
7.12"
.62"
4.81"
2.72"
3.12"
SurfaceMounting
5.62"
2.50"2.50"
1/4" NPT
1/4" NPT
0.25" Dia. Screws
4.81"
.91"
8.50"
56R
8.62"
2.59"
.91"
2.00"
2.00"
.91"
1.16"
Case Tapped 1/4" NPT for Vent
Estimated Shipping Weight 13 lbs.
9.38" 2.72"
2.50"2.50"
8.50"
8.62"
.56R
9.50"
5.62"
1/4"NPT1/4"
NPT.91"
3.12"
1.16"
Back View
Panel Cutout Dimensionsfor Panel Mounting 2.50
SurfaceMounting
Mallard Model 3350/3360
19
Mallard Control
Mallard Pressure Controllers
3300 -005 R 2 N 5
Controller Mode00 • Proportional50 • Proportional60 • Proportional -Plus-Reset
Input Signal RangeModel 3300 Only 005 • 0-50 psig010 • 0 -100 psig025 • 0-250 psig050 • 0 -500 psig100 • 0-1000 psig150 • 0-1500 psig250 • 0-2500 psig500 • 0-5000 psig
Controller ActionD • Direct (Increase Output on Increasing Pressure)R • Reverse (Decrease Output on Increasing Pressure)
Controller Output1 • 3 -15 psig2 • 6 -30 psig
Options– • NoneN • NACE Compliant for Sour Gas Service
Mounting0 • None1 • Actuator Yoke2 • Actuator Housing
Example
Model 3350 /3360 Only003 • 0 -30 psig006 • 0-60 psig010 • 0-100 psig020 • 0-200 psig030 • 0-300 psig060 • 0-600 psig100 • 0-1000 psig150 • 0-1500 psig300 • 0-3000 psig
3 • Panel4 • 2" Pipestand5 • Surface (Wall)
Note: The panel mount cutout recommendation is 715/16" - 8" tall x 615/ 16" -7" wide. With these dimensions, the brackets must be removed and the controller inserted from the front of the panel. After inserting the controller, reattach the brackets and mount the cotroller to the panel from the back.
Part Number Codes & Unit Action
Mallard pressure controllers can be installed a number of differents ways. The most common method is mounting the controller on a control valve yoke. When the controller is mounted in this manner, a supply regulator (Mallard Model 5602 recommended) is typically mounted on the opposite side of the actuator yoke. Alternatively, the supply regulator can be nipple-mounted to the controller. When the opposite side of the actuator yoke is occupied by a positioner or other device, nipple-mounting of the supply regulator is required.
Installation Temperature Limits Model 3300 Model 3350 /3360 -40 to 150˚F (-40 to 66˚C) -40 to 160˚F (-40 to 71˚C)
Materials of Construction Description Material Case & Cover Die Cast Aluminum Bourdon Tube Stainless Steel Pressure Block Stainless Steel Supply & Output Tubing Stainless Steel Input Pressure Tubing Stainless Steel Nozzle Stainless Steel Orifice Block Aluminum Mounting Bracket Plated Steel, Stainless Steel (Optional)
CIRCOR Energy is a global manufacturer of highly engineered valve and pipeline products that continuously develops precision technologies to improve our customers’ ability to control the flow of the world’s natural
resources, from sub-sea to land, and in severe environments.
Continuously Improving Flow Control. Worldwide.
©2013 CIRCOR Energy. All rights reserved.MALL-CONTRLVLVS-JUNE-2013-2UP-HP
www.circorenergy.com
China
10# Qun Xing San Road
Loufeng District Suzhou
Industry Park
China Post Code: 215006
Tel: +86 512 62516088
Fax: +86 512 62513119
sales.china@circor.com
Asia Pacific
10 Woodgrove View
Singapore 738113
Tel: +65 63101595
Fax: +65 62691973
sales.asia@circor.com
United States
Oklahoma City
1500 S.E. 89th St.
Oklahoma City, OK 73149
Tel: 405.631.1533
Fax: 405.631.5034
sales@circorenergy.com
Houston
Corporate & Sales
945 Bunker Hill, Suite 650
Houston, TX 77024
Tel: 832.912.8333
sales@circorenergy.com
U.A.E.
P.O. Box: 263202
Unit FZS5 AA01
Jebel Ali Free Zone
Dubai, UAE.
Tel:+971.4.8866128
Fax: +971.4.8866129
sales.dubai@circor.com
Canada
Calgary
Suite 2604, 308 4th Ave. SW
Calgary, Alberta T2P 0H7
Tel: 403.266.6500
Fax: 403.266.5088
sales.canada@circor.com
Edmonton
9430-39th Avenue
Edmonton, Alberta T6E 5T9
Tel: 780.463.8633
Fax: 780.461.1588
sales.canada@circor.com
Brazil
1480, Eugenio Losso District St.
Unileste - 13422-180
Piracicaba - Sao Paulo - Brazil
Tel: +55.19.3124-3124
Fax : +55.19.3414-3722
sfvalvulas@circor.com.br
Latin America
1500 S.E. 89th St.
Oklahoma City, OK 73149
Tel: 405.631.1533
Fax: 405.631.5034
sales@circorenergy.com
Viton® is a registered trademark of DuPont Dow Elastomers. • Kevlar® is a registered trademark of DuPont. • Kalrez® is a registered trademark of DuPont Performance Elastomers, L.L.C. • Inconel® is a registered trademark of Special Metals Corporation, USA. Grafoil® is a registered trademark of Union Carbide Corporation. • Aflas® is a registered trademark of Asahi Glass. • Stellite® is a registered trademark of Kennametal Stellite.
Mallard reserves the right to change designs, materials, or specifications without notice or without obligation to furnish or install such changes on products previously or subsequently sold.