Post on 27-Aug-2018
transcript
SulfurSmart SulfurAlert SulfurGuard PCLink EnviroTape SulfurGuard ET YellowJacket ET
Area of Classification GP, C1D2, C1D1 GP, C1D2 GP, C1D2 C1D2 C1D2 GP, C1D2 GP, C1D2
Concentration Range 0-50, 0-5, 0-50, 0-5, 0-50, 0-50 PPM 0-50, 0-300 PPM, 0-% 0-5, 0-50, 0-50, 0-300 PPM 0-300 PPM, 0-% 0-500 PPM , 0-% 0-500 PPM , 0-% 0-500 PPM , 0-%
Input Power 12-24VDC, 110/220VAC 110/220VAC 12-24VDC, 12-24VDC, 110/220VAC 11.1V Lith-Ion Battery 110/220VAC 110/220VAC 110/220VAC
Repeatability +/- 1% +/- 1% +/- 1% +/- 1% +/- 2% +/- 2% +/- 2%
Response Time < 60 Seconds < 60 Seconds < 60 Seconds < 60 Seconds < 60 Seconds < 60 Seconds < 60 Seconds
Zero Drift None None None None None None None
Linearity +/- 2% +/- 2% +/- 2% +/- 2% +/- 2% +/- 2% +/- 2%
Operating Temperature 0°-50°C 0°-50°C 0°-50°C 0°-50°C -20°-50°C -20°-50°C -20°-50°C
Tape Life( average) 30 Days 30 Days 30 Days 30 Days 30 Days 30 Days 1 Days
Options
4-20mA Output 1-2 Channel(s) 1-2 Channel(s) 1-4 Channel(s) 1-2 Channel(s) 1-2 Channel(s) 1-4 Channel(s) 1 Channel
Concentration Alarm(s) 2 2 2 2 2 2 Not Available
Diag. and Maintenance Diag Diag Diag Diag Diag and Maint. Diag and Maint. Not Available
Data Logger Optional Optional Optional Standard Optional Optional Standard
Modbus Optional Optional Optional Standard Optional Optional Not Available
AutoCal Optional Optional Not Available Not Available Optional Optional Not Available
Cabinet Heater VAC / Cataylic Not Applicable Not Applicable VAC / Cataylic Not Applicable Not Applicable Not Available
DEL MAR SCIENTIFIC, LTD4951 Airport Parkway, Suite 803
Addison, Texas 75001
972-661-5160 Main Number
800-722-4270 Toll Free Number
972-490-9243 Fax
www.delmarscientific.com
Hours: Monday - Friday 8am - 4:45pm
Since 1973, Del Mar Scientific has manufactured superior analyzers for the detection and analysis of Hydrogen Sulfide and Total Sulfur. From the early analog units to today’s digital designs, our engineers have lead the industry with advancements and cutting edge designs for natural gas, beverage, wastewater and many others. The latest developments, that eliminate all chemical waste and disposal issues, insure that we will continue to lead the industry while offering exceptional value for long
term protection against Hydrogen Sulfide and Total Sulfur.
Marshall T Schreve, President, CEO
MISSION STATEMENT: We are passionately committed to being the world’s leading innovator, developer and supplier of Hydrogen Sulfide and Total Sulfur measurement and monitoring devices and services.
EnviroTapeEnviroTape is to be used exclusively with hydrogen sul�de analyzers manufactured by Del Mar Scienti�c, Ltd with the
EnviroTape Operating System. �is product is not compatible with any other hydrogen sul�de analyzer or detector.�is product is 100% lead free. For additional product information contact Del Mar Scienti�c, Ltd.
Del Mar Scienti�c, Ltd.4951 Airport Parkway
Suite 803Addison, TX 75001
Phone: 972-661-5160Fax: 972-490-9243
www.delmarscienti�c.com
Store
in cool, d
ry plac
e
Dispose
of acco
rding to lo
cal an
d state
regulat
ions
305-0030-00 30 day supply
AMERICAN MADE:All of our exceptional products are manufactured at our facilities in Addison, Texas, offering flawless accuracy for an imperfect world.
SulfurAlert™ The SulfurAlert™ Total Sulfur Gas Analyzer is designed to analyze and monitor concentration levels of Total Sulfur in continuous flowing and pressurized streams, providing real-time values via local display and analog and/or digital signal.
Models are available for General Purpose and Class 1, Division 2 area classifications. Models are available for all analysis ranges.
SulfurSmart™ The SulfurSmart™ Series H2S Analyzers are designed to analyze and monitor concentration levels of Hydrogen Sulfide (H2S) in continuous flowing and pressurized gaseous streams, providing real-time values via local display and analog and/or digital signal. Models are available for General Purpose; Class 1, Division 2; and Class 1, Division 1 area classifications. Models are available for all analysis ranges.
EnviroTape™ H2S AnalyzerThe EnviroTape™ H2S Analyzer uses the proprietary EnviroTape™ sensing tape, which eliminates the requirement for humidification. EnviroTape™ uses a Silver Nitrate formula that is classified as non-hazardous, while maintaining the same qualities as the Lead Acetate (ChemFilm™) analyzers.
• 30 Days Hands-Off Operation• Time Proven Paper Tape Detector• -20°C to +50°C operating range without a heater• Large Touch Screen Control Panel• Compact 18X18X8 Stainless Steel• Integrated Modular Sample System• Light Weight (60 pounds total weight)• Modular Construction, Field Repairable• Multi Faceted, Programmable Communication
YellowJacket ET™ The YellowJacket ET™ is a compact, rugged and portable H2S analyzer for measurement of H2S in gaseous streams at multiple remote field sites. The YellowJacket ET™ features an internal sample conditioning system, graphical display with touch screen, digital data-logging via flash memory,and spreadsheet-style data collection mode for storing other gas quality data on the flash memory. The YellowJacket ET™ uses our proprietary lead-free EnviroTape™ that does not require humidification.
Applications:•RapidHydrogenSulfideAnalysis •CalibrationCheckforOnlineHydrogen Sulfide Analyzers •-20°Cto50°Coperatingrange
PCLink™The PCLink™ Series H2S Analyzers are designed to analyze and monitor concentration levels of Hydrogen Sulfide in continuous flowing and pressurized gaseous streams, providing real-time values via local display and analog and/or digital signal.
Models are available for General Purpose and Class 1, Division 2 area classifications. Models are available for all analysis ranges.
SulfurGuard™The SulfurGuard™ is a Dual Analysis Sulfur Analyzer designed for simultaneous analysis of H2S and Total Sulfur in the same continuous flowing and pressurized gaseous stream without purging, diluting or stream switching, providing real-time values via local display and analog signal. The SulfurGuard™ series includes models for General Purpose and Class 1, Division 2 area classifications. Models are available for all analysis ranges.
SulfurGuard ET™ The SulfurGuard ET™ is a Dual Analysis Sulfur Analyzer designed for simultaneous analysis of Hydrogen Sulfide and Total Sulfur in the same continuous flowing and pressurized gaseous stream without humidification, purging, diluting or stream switching, providing real-time values via local display, analog signal, and an Integrated Modular Sample System. -20°C to +50°C operating range without a heater. The SulfurGuard ET™ series uses the proprietary EnviroTape™ and includes
models for General Purpose and Class 1, Division 2 area classifications. Models are available for all analysis ranges.
COMPLIANCES:EPA Fuel Gas Monitoring ~ 40 CFR 60, Subpart J Lead Acetate Reaction Rate Method: ~ ASTM 4084Total Sulfur by Hydrogenolysis ~ ASTM 4045