Post on 10-Mar-2020
transcript
2010
Committing to the future
hPa
mbar
Pa
mm H2O
inch H2O
inch Hg
mm Hg
psi
m/s
fpm
Measuring Instruments for Pressure and Refrigeration
Rel
ativ
e va
cuum
Pressure sensitive element
Absolute pressure (Pabs)
The pressure which applies to the va-cuum in the universe (zero pressure) isknown as absolute pressure. Absolutepressure has “abs” as its index.
MMeasuring principle
When designing pressure meters, the principle of the effect of pressure on a defined area is almost always used. This is thenretraced to a measurement of force.
The following formula applies:
Differential pressure, pressure difference(Δp)
The difference between two pressuresp1 and p2 is known as pressure diffe-rence (Δp= p1-p2). If the difference bet-ween two pressures is a variable, this isreferred to as differential pressure (p1,2).
Atmospheric pressure difference, posi-tive pressure
Atmospheric pressure difference (pe) isthe difference between an absolutepressure (pabs) and the respective atmo-spheric pressure (pe = pabs - pamb). Thisis generally referred to as positive pres-sure.
Atmospheric air pressure (Pamb)
This is the most important pressure for life on earth. Atmospheric pressure is crea-ted by the weight of the atmosphere surrounding the earth. The atmosphere rea-ches a height of up to approx. 500 km. Pressure decreases constantly up to thisheight (absolute pressure Pabs = zero). Atmospheric air pressure is also influencedby fluctuations in the weather. The average Pamb at sea level is 1013.25 Hectopas-cal (hPa) or millibar (mbar/ normal pressure in accordance with DIN 1343). Typicallythis value can fluctuate by ±5 % if there are low or high pressure weather areas.
Pressure sensitive element
Pressure sensitive element
Pressure (p) =Force (F)
Area (A)
Measuredpressure
Measuredpressure 2
Atm
osph
eric
pre
ssur
e
Different pressure types
Pressure meters
Measuredpressure 1
Measuredpressure
Types of pressure metersAdvantages: Electrical pressure meters
There is a displacement of 1-3 mm inelastic pressure meters. The deformation in electrical pressuresensors is only a few μm. Due to thisvery low mechanical deformation, elect-rical pressure meters / sensors have anexcellent dynamic performance and lowmaterial stress resulting in high endu-rance levels and long-term stability.Electrical pressure meters can also bemanufactured in very small sizes.
An additional advantage is the easy-to-read display. Considering today’s tech-nology standards, accurate pressuremeasurement is becoming more andmore important. Precision measuring
meters have an accuracy of ±0.05 % ofthe full-scale value. In the case of me-chanical manometers, such accuraciescannot be read on account of the paral-lax error and mechanical performanceof the springs. Electrical precision me-ters with LCD display often have a reso-lution in the thousandth range of 0.001.
Liquid pressure meters– U-tube manometer– Inclined tube manometer– Multi-liquid manometer– Float manometer
Pressure balances with sealing liquid
Piston pressure meters– Piston pressure meters with spring-
loaded piston– Piston pressure scales
Elastic pressure meters
Electric pressure sensors and pressure meters– Sensor principles with strain meters– Sensor principles with path measure-
ment– Compression meter– Ionisation pressure meter– Friction meter
Pa hPa/mbar
Pa
hPa/mbar
kPa
MPa
bar
psi
mmH2O
inH2O
mmHg
inHg
kPa MPa bar psi mmH2O inH2O mmHg inHg
1
0.01
0.001
0.000001
0.00001
0.0001451
0.102
0.004016
0.007501
0.0002953
100
1
0.1
0.0001
0.001
0.0145
10.2
0.4016
0.7501
0.0295
1.000
10
1
0.001
0.01
0.14505
102
4.016
7.501
0.2953
1.000.000
10.000
1.000
1
10
145.05
102.000
4.016
7.501
295.3
100.000
1.000
100
0.1
1
14.505
10.200
401.6
750.1
29.53
6.895
68.948
6.895
0.006895
0.0689
1
704.3
27.73
51.71
2.036
9.807
0.09807
0.009807
0.000009807
0.00009807
0.001422
1
0.0394
0.0734
0.002891
249.1
2.491
0.2491
0.0002491
0.002491
0.0361
25.4
1
1.865
0.0734
133.3
1.333
0.1333
0.0001333
0.001333
0.0193
13.62
0.5362
1
0.0394
3.386
33.864
3.386
0.003386
0.0339
0.4912
345.9
13.62
25.4
1
Pressure measurement engineeringInformation
2
Conversion table for the most important pressure units
3
Contents
Pressure meters
Pocket size differential pressure and flow meter 4testo 510Pocket-size absolute pressure meter 5testo 511
67
1214
18192020
Pressure and flow velocity measuring instrumenttesto 512Pressure meters for gas and water fitterstesto 312-2, testo 312-3
9All measurement tasks on gas heating systems, pipelines and water pipestesto 312-410The complete testing system for gas and water pipestesto 314
Highly Accurate Pressure Meters for Industrial Applicationstesto 525Reference pressure meters for all measurement rangestesto 521, testo 526
Page
Refrigeration metersPage
Leakage Detector for Refrigerantstesto 316-4Electronic manifoldtesto 523Electronic refrigeration analyser with data management (brass connections)testo 556-1Electronic refrigeration system analyser with data management (stainless steel connections)testo 556-2
21Electronic refrigeration analyser with data management and vacuum sensor (brass connections)testo 560-121Electronic refrigeration system analyser with data management and vacuum sensor (stainless steel connections)testo 560-2
Additional information at4
Pocket size differential pressure and flow metertesto 510
Display in Pascal possible over entiremeasurement range
Accuracy: ±0.03 hPa (0 to 0.30 hPa) /±0.05 hPa (0.31 to 1.00 hPa)
Temperature compensation
Magnetic rear permits free-hand work
Flow velocity measurement with Pitottube (Pitot tube not included in deli-very)
Air density compensation
Protective cap for safe storage
Including wrist strap and belt holder
Backlit display
Switchable units: hPa, mbar, PammH2O, mmHg, inH2O, inHg, psi,m/s, fpm
The differential pressure meter isideally suitable for pressure mea-surements in the range 0 to 100hPa.
testo 510's differential pressuremeasurement is temperature-compensated for accurate rea-dings. Readings can be displayedin Pascal over the whole measu-rement range.
Magnets at the back of the instru-ment enable hands-free opera-tion, for instance, while adjustinggas heaters.
Part no.
0560 0510
testo 510; differential pressuremeter incl. protective cap, batteriesand calibration protocol
Technical data
www.testo.comwww.testo.com
Zubehör Part no.AccessoriesHose set: Connection hose, silicone, 2 m long, max. load 700 hPa (mbar) 0554 0448
ISO calibration certificate relative pressure, 3 measurement points distribu-ted over the measurement range
0520 0085
ISO calibration certificate/pressure, differential pressure, accuracy 0.1 to 0.6(% of fsv)
0520 0025
119 x 46 x 25 mm (incl.protective cap)
0.01 hPa
2 batteries Type AAA
0 to +50 °C 2 years
±0.03 hPa (0 to 0.30hPa)±0.05 hPa (0.31 to 1.00hPa)±(0.1 hPa + 1.5 %of mv)(1.01 to 100 hPa)
90 g (with batteries andprotective cap)
-40 to +70 °C
0 to 100 hPa
Dimensions0.5 sMeasurement rate
hPa, mbar, Pa, mmH2O,inH2O, inHg, mmHg, psi,m/s, fpm
Selectable units
50 h (average, withoutdisplay illumination)
Battery life
Resolution
Battery type
Oper. temp.
±1 digit
Warranty
IP40Protection classAccuracy
Weight
Storage temp.
Meas. range
max. static pressure 1.5 barPositive pressure 500 mbar
Additional information at www.testo.comwww.testo.com 5
Pocket-size absolute pressure metertesto 511
Measures absolute pressure, e.g. forabsolute pressure compensation inflow velocity measurements with aPitot tube
Calculation of barometric air pressure
Barometric altitude measurement
Accuracy +/-3 hPa
Protective cap for safe storage
Including wrist strap and belt holder
Backlit display
8 switchable pressure units: hPa,mbar, Pa, mmH2O, mmHg, inH2O,inHg, psi
testo 511 measures absolutepressure with an accuracy of +/-3hPa.
It is converted to barometric airpressure by entering on-siteheight above sea level.
In addition, barometric elevationmeasurement between two pointsis also possible.
Part no.
0560 0511
testo 511; absolute pressure meterincl. protective cap, batteries andcalibration certiificate
Technical data Zubehör Part no.AccessoriesHose set: Connection hose, silicone, 2 m long, max. load 700 hPa (mbar) 0554 0448
119 x 46 x 25 mm (incl.protective cap)
0.1 hPa
2 batteries Type AAA
0 to +50 °C
±3.0 hPa
-40 to +70 °C
300 to 1200 hPa
Dimensions
0.5 sMeasurement ratehPa, mbar, Pa, mmH2O,mmHg, inH2O, inHg, psi,m, ft
Selectable units
200 h (average, withoutdisplay illumination)
Battery lifeResolution
Battery type
Oper. temp.
±1 digitAccuracy
Storage temp.
Meas. range
2 years
90 g (with batteries andprotective cap)
Warranty
IP40Protection class
Weight
ISO calibration certificate/absolute pressure, 3 meas. points distributed overmeas. range
0520 0185
ISO calibration certificate/absolute pressure, 5 measurement points distribu-ted over meas. range
0520 0125
Transport and Protection
Printer and accessories
Additional accessories and spare parts
Calibration certificates
Accessories for measuring instrument
Additional information at
Simultaneous display of flow and pres-sure value
0 to +60 °C-10 to +70 °C
9V block battery, 6F22All non-corrosive gases
±10 hPa
0.001 hPa0.1 m/s0.1 fpm
0.5% of fsv ±1 digit
0 to +2 hPa+2 to +17.5 m/s395 to 3445 fpm
www.testo.comwww.testo.com
Resolution
Battery typeMeasuring medium
LCD, 2 linesDisplay
10 minAuto Off
Oper. temp.
Accuracy
Storage temp.
Meas. range
Overload
202 x 57 x 42 mm
2 years300 g
Dimensions120 hBattery life
WarrantyWeight
Pressure and flow velocity measuring instrumenttesto 512
8 units for pressure: kPa, hPa, Pa,mm H2O, mmHg, psi, inch H2O, inchHg
2 units for flow: m/s, fpm
Built-in density compensation
Display light
Hold/Max/Min function
Readings printout with date/time andmin./max. values
testo 512 shows pressure andflow velocity simultaneously in aneasy-to-read, large, backlit dis-play. Measurement data is printedon site with date and time as wellas minimum and maximum va-lues. testo 512 has two switcha-ble units for flow: m/s and fpm.Eight units can be set for pres-sure: kPa, hPa, Pa, mmH2O,mmHg, psi, inch H2O, inch Hg.
Adjustable damping for slidingmean calculation, density com-pensation is built-in. The dis-played actual value can be frozenin the display by pressing theHOLD button. The measured mi-nimum and maximum value canbe displayed and stored in themeter.
TopSafe protects the measuringinstrument in the field from im-pact, dirt and splash water.
Part no.
0560 5126
testo 512 differential pressuremeter, 0 to 2 hPa, incl. battery andcalibration protocol
0 to 2 hPa/mbar
0 to 20 hPa/mbar
0 to 200 hPa/mbar
0 to 2000 hPa/mbar w/o flow ve-locity and Pascal measurement
Zubehör Part no.Accessories
6
11
Part no.
0560 5127
testo 512 differential pressuremeter, 0 to 20 hPa, incl. battery andcalibration protocol
2
Part no.
0560 5128
testo 512 differential pressuremeter, 0 to 200 hPa, incl. batteryand calibration protocol
3
Part no.
0560 5129
testo 512 differential pressuremeter, 0 to 2000 hPa, incl. batteryand calibration protocol
4Common data
Technical data
±200 hPa
0.01 hPa0.1 m/s0.1 fpm
0 to +20 hPa+5 to +55 m/s985 to 10830fpm
2
±2000 hPa
0.1 hPa0.1 m/s0.1 fpm
0 to +200 hPa+10 to +100 m/s1970 to 19690fpm
3
±4000 hPa
1 hPa
0 to +2000 hPa4
Zubehör Part no.Accessories
TopSafe, protects from impact and dirt 0516 0221
Connection hose, silicone, 5m longmax. load 700 hPa (mbar)
0554 0440
Pitot tube, 350 mm long, Ø 7 mm, stainless steel, measures flow speed 0635 21459V rech. battery for instrumentinstead of battery
0515 0025
Recharger for 9V rechargeable batteryfor external recharging of 0515 0025 battery
0554 0025
Case for measuring instrument and probes 0516 0210
Pitot tube, 500 mm long, Ø 7 mm, stainless steel, measures flow speed 0635 2045
Pitot tube, 1000 mm long, stainless steel, measures flow speed 0635 2345
Hose connection set for gas pressure measurement on heating systems,incl. silicone hoses and T-pieces
DKD calibration certificate/pressurediff. and pos. pressure; 11 measuring points distributed over the instr. meas. range
0554 0315
0520 0215
Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4AA batteries
0554 0549
Spare thermal paper for printer (6 rolls), permanent inkmeasurement data documentation legible for up to 10 years
0554 0568
Transport case for meas. instr. and probes (405 x 170 x 85 mm) 0516 0201ISO calibration certificate/pressure, differential pressure,accuracy 0.1 to 0.6 (% of fsv)
0520 0025
+5 to +45 °C
-20 to +70 °C
9V block battery
±1000 hPa (-40 to+40 hPa)
testo 312-2
0.01 hPa (-40 to+40 hPa)
±1.5% of mv. (+3to +40 hPa)±0.03 hPa (0 to+3 hPa)
±0.5 hPa (0 to+50 hPa)±2 hPa (+50 to+200 hPa)
-40 to +40 hPa
Resolution
Battery type
Measurement range can be switched from ±40hPa to ±200 hPa
Setting step: 0.01 hPa or 5 hPa
Alarm threshold: -0.04 hPa or 100 hPa
Alarm display: Audible and visual if limit valuesare reached
LCD, 2 linesDisplay
ABSMaterial/Housing
Oper. temp.
Accuracy
Storage temp.
Meas. range
Overload
215 x 68 x 47 mm
2 years300 g
Dimensions
WarrantyWeight
Pressure meters for gas and water fitterstesto 312-2
Switchable precision range with ahigh resolution
Alarm when user-defined limit valuesare exceeded
Printout of data incl. software, instru-ment number, date/time on Testoprinter
Clear display with time
DVGW approval
testo 312-2, DVGW approval ac-cording to TRGI, measures pres-sure from 0 to 200 hPa. Even thefinest of pressures with a resolu-tion of 0.01 mbar can be measu-red in the measuring range from 0to 40 mbar.
Part no.
0632 0313
testo 312-2, precision manometerup to 40/200 hPa, DVGW approval,incl. alarm display, battery and cali-bration protocol
testo 312-3
testo 312-3, the versatile mano-meter for the pre-test and maintest on gas and water pipelines upto 6 bar. Pressure changes causedby changes in temperature duringthe measurement are balancedout by the temperature compen-sation function.
Part no.
0632 0314
testo 312-3, robust manometer upto 300/6000 hPa, DVGW approval,incl. alarm display, battery and cali-bration protocol
Zubehör Part no.Probes
Zubehör
Transport and Protection
Printer and accessories
Additional accessories and spare parts
Part no.Accessories
Common data
Technical data
±1000 hPa (-200to +200 hPa)
0.1 hPa (-200 to+200 hPa)
-200 to +200 hPatesto 312-3
±0.5 hPa (0 to+50 hPa)±1.5 hPa (+50 to+300 hPa)
±8000 hPa (-300to +300 hPa)
±8000 hPa (-6000to +6000 hPa)
0.1 hPa (-300 to+300 hPa)
-300 to +300 hPa
±2% of mv. (+400to +2000 hPa)±4% of mv. (+2000to +6000 hPa)±4 hPa (0 to +400hPa)
1 hPa (-6000 to+6000 hPa)
-6000 to +6000hPa
±1 digit
215 mm
Ø 5 mm
Pressure set with flue draught probe, consisting of: 2 x silicone hoses Ø 4mm and Ø 6 mm respectively, 4 mm and 6 mm T-piece, connection piece
0554 3150
Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4AA batteries
0554 0549
External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batterieswith individual cell charging and charge control display, incl. impulse tricklecharging, integrated discharge function, with built-in international mainsplug, 100-240 V, 300 mA, 50/60 Hz
0554 0610
Spare thermal paper for printer (6 rolls) 0554 0569
Spare thermal paper for printer (6 rolls), permanent ink, measurement datadocumentation legible for up to 10 years
0554 0568
9V rech. battery for instrument, instead of battery 0515 0025
Recharger for 9V rechargeable battery, for external recharging of 05150025 battery
0554 0025
TopSafe (protection case), with bench stand, protects instrument from dirtand impact
0516 0443
Case, for secure storage of measuring instrument 0516 0191
Transport case (plastic), for transport and secure storage of measuring in-strument and accessories
0516 3120
Calibration certificatesISO calibration certificate/pressure, differential pressure; 5 points distributedover meas. range
0520 0005The complete maintenance set with documentationZubehör
- Pressure measuring instrument up to 40/200 hPa (Part no. 0632 0313)
- TopSafe (protection case), with bench stand (Part no. 0516 0443)
- Pressure set (Part no. 0554 3150)
- testo 316-1, gas leak detector (Part no. 0632 0316)
- TopSafe for testo 316, protection case incl. stand, protects from dirt and impact (Part no. 05160189)
- Testo report printer (Part no. 0554 0549)
- Case (plastic) (Part no. 0516 3120)
Recommended set
Additional information at www.testo.comwww.testo.com 7
See next page for test system for gas and water fitters
See next page for high pressure set
Additional information at8
Complete test system for gas/water fitterstesto 312
Testing system set
• Printout with date
• Load and gas-tightness test on gaspipelines
• Pressure check on water pipelines
• Efficient leak detection
Everything you need to inspectgas and water pipeline installati-ons: Check pressure drop usingthe testo 312-3 electronic pres-sure meter. The measurement re-sults are output on the printer.Using slide rule, you can quicklydetermine the amount of gas lea-king and thus the serviceability ofthe gas pipelines. A gas leak isquickly detected by testo 316-1.
Part no.
0563 0314
testo 312-3 pressure meterTopSafe for testo 312Printertesto 316-1 gas leak detectorTopSafe for testo 316-1Accessories: Pressure drop test set200 mbar, testing pump, single-pipecounter cap, two valve T-fitting, sin-gle valve barrier, connection hoseLW 6, conical test plugs 1/2", 3/4",high pressure stage stops 3/8",3/4", 1/2", 1", leak detection spray,slide rule, system case
High pressure set with case (withoutinstrument)
Part no.
0554 3160
Pressure drop test set, 200 mbarTesting pump, greater than 500mbarSingle-pipe counter capTwo-valve T-fittingSingle-valve barrierConnection hose LWConical test plugs 1/2" and 3/4"High pressure stage stop 3/8", 1/2",3/4", and 1"Leak detection spraySystem case
www.testo.comwww.testo.com
Zubehör Part no.AccessoriesPressure drop test set 200 mbar, incl. manual bulb pump, hoses, T-fitting w/valve, conical test stopper 1/2"
0554 3153
Test pump to produce test pressure 0554 3157
Single-pipe counter cap, connects test fittings to pipe, Simply dismantlegas counter, attach single-pipe counter cap and connect hose
0554 3156
Two-valve branch (brass) to connect 2 or more pipes, can be blocked off se-parately
0554 3161
Single-valve stop to block off pipe, e.g. when changing hoses during a test 0554 3162
LW 6 connection hose, To connect T-fitting/single-pipe counter cap or for ex-tension purposes
0554 3158
Conical test stop 1/2" for connecting test set to the gas pipe 19–32 mm,Connects test fittings to pipe
0554 3151
Conical test stop 3/4" for connecting the test set to the gas pipe 24-44 mm,Connects test fittings to pipe
0554 3155
Conical test stop 1" to connect test fittings to gas pipe 35–65 mm,Connects test fittings to pipe
0554 3152
High pressure stage stop 3/8" and 3/4", To connect test fittings to gas pipe 0554 3163
High pressure stage stop 1/2" and 1", To connect test set to gas pipe 0554 3164
Leak detection spray for spraying on the gas pipe, shows leaking pointswhere bubbles form, To detect leaks (bubbles appear) in gas pipes
0554 3166
System case for the complete test system, Ensures orderly storage of casecontents
0554 3165
Slide rule to quickly determine serviceability 0554 3169
DKD calibration certificate/pressure, diff. and pos. pressure; 6 meas. pointsdistributed over meas. range (>0.6% of fsv)
0520 0225
Please order the testo 312-3 or testo 312-2 instrument suitable for your requi-rements
Part no.
0632 0313
testo 312-2, precision manometerup to 40/200 hPa, DVGW approval,incl. alarm display, battery and cali-bration protocol
Part no.
0632 0314
testo 312-3, robust manometer upto 300/6000 hPa, DVGW approval,incl. alarm display, battery and cali-bration protocol
DVGW-TRGI appro-ved
Additional information at www.testo.comwww.testo.com 9
Fulfilling all measurement tasks on gas heating systems and on gas and water pipes. testo 312-4
• Gas-tightness and serviceability testby pressure drop on gas pipes accor-ding to DVGW-TRGI 2008
• Load test on gas pipes according toDVGW-TRGI 2008 with the help ofthe high pressure probe
• Checking the regulator by recordingthe measurement values over a defi-ned period
• Checking the gas connection pres-sure and gas flow pressure as well assetting the jet pressure on gas bur-ners and boilers
• Pressure tests on drinking waterpipes with water using the high-pres-sure probe according to DIN 1988(TRWI) as well as with air accoding tothe ZVSHK information sheet
• Pressure test on waste water pipesaccording to DIN EN 1610 using thehigh pressure probe
A measuring instrument for carry-ing out all necessary tests on gasheaters and pipes as well aswater pipes. Inherently safethanks to the use of C-Flex hoseswith high impermeability. Legallycompliant measurement proce-dure for pre-test, main test andleakage quantity measurement ongas pipes. Recording of measure-ment values over a defined period(e.g. 24 h) and data transfer andanalysis on PC software incl. gra-phic presentation.
Technical data testo 312-4
Part no.
0632 0327
Differential pressure gauge testo312-4
Differential pressure gauge testo312-4
Hose set for testo 312-4
Balloon pump with release screw
Conical test plug 1/2"
Conical test plug 3/4"
Testo fast printer
Pressure set for gas pressuremeasurements on heating sys-tems
System case
Basic set testo 312-4 Zubehör Part no.AccessoriesPressure set for gas pressure measurement on heating systems 0554 0449Hose set for testo 312-4 0554 3172Balloon pump with release valve 0554 3173
0554 31510554 31550632 03160554 31560554 3161
0554 31620554 31580554 3166
0554 11430554 31570515 00250554 00250554 0549
0554 05680516 04460516 0189
0516 31210638 17430554 31630554 31640600 4593
0604 0194
0430 01430554 3332
0409 0178
Conical test stop 1/2" (19 - 32mm)Conical test stop 3/4" (24 - 44 mm) testo 316-1, gas leak detectorSingle-pipe counter cap, connects test fittings to pipeTwo-valve branch (brass) to connect 2 or more pipes, can be blocked offseparately
Single-valve stop to block off pipeLW 6 connection hoseLeak detection spray for spraying on the gas pipe, shows leaking pointswhere bubbles form
Desk-top power supply with international connection optionsTest pump to produce test pressure9V rech. battery for instrumentRecharger for 9V rechargeable batteryTesto fast printer with wireless infrared interface, 1 roll thermal paper and 4AA batteries
Spare thermal paper for printer (6 rolls), permanent inkTopSafe (protection case)TopSafe for testo 316, protection case incl. stand, protects from dirt andimpact
System caseHigh-pressure probe up to 25 barHigh pressure stage stop 3/8" and 3/4"High pressure stage stop 1/2" and 1"Pipe wrap probe for pipes with diameter of up to 2", for flow/return temp.meas. in hydronic systems
Quick-action surface probe with sprung thermocouple strip, measuringrange short-term to +500°C
Connection cable, length 1.5 m, for probes with plug-in headsAnalysis software, shows measurement in form of diagrams, tables andmanages customer data
RS232 cable
Part no.
0563 1327
Differential pressure gauge testo312-4
Hose set for testo 312-4
Balloon pump with release screw
Conical test plug 1/2"
Conical test plug 3/4"
Testo fast printer
Pressure set for gas pressuremeasurements on heating sys-tems
High-pressure plug 3/8" and 3/4"
High-pressure plug 1/2" and 1"
High-pressure probe 1up to 25 bar
System case
High-pressure set testo 312-4
Part no.
0563 1328
Pressure (internal sensor in the testo 312-4)0 to 200 hPaMeas. range
±0.03 hPa (0 to +3 hPa)±1.5% of mv (+3.1 to+40 hPa)±2 hPa or ±1% of fsv(+41 to +200 hPa)
dependent on probe typeused
0 to 25 bar±0.5% of fsv
RS 232Easyheat
infrared
±0.4 °C (-100 to +200°C)±1 °C (remaining range)
Accuracy
Temperature (via external tempera-ture probe Type K)
Meas. range
Accuracy
Pressure (via high-pressure probe)Meas. rangeAccuracy
10 hPaResolution
Miscellaneous instrument data
Interface for printer
Interface for PCPC software
Approx. 25.000 readingsMeasurement datastore
autoMeasurement rate
fast 1 s to 24 h
0.04 s219 x 68 x 50 mmDimensionsApprox. 600 gWeight2 yearsWarranty
The complete testing system for gas and water pipestesto 314
• Load and gas-tightness test on gaspipes
• Fast measurement of amount of gasleaking according to DVGW-TRGI2008 VP 952
• Efficient detection of gas leaks usingtesto 316-1
• Analysis software to show course ofmeasurement
• Serviceability test on gas pipes• Data recording for testing pressure re-
gulator• Analysis with PC software• Pressure test on waste water pipes
according to DIN EN 1610 using thehigh pressure probe (available as anoption)
Tested according toDVGW-TRGI 2008 /
VP 952
Unique
Efficient measurement due to ab-solute pressure compensation
testo 314 independently compen-sates fluctuations in absolutepressure during volume flow mea-surement via absolute pressurecompensation.
Fast
Zeroing phase for connected pipe
To determine ΔP efficiently andquickly, zeroing to ambient airpressure takes place while themeasurement is in progress. Thiseliminates interruptions and remo-val of pipes.
Efficient
Measuring using standard testpressure compensation with fee-ding unit
The flow test which is indepen-dent of gas mains, has the advan-tage that pressure fluctuations inpipes can be compensated. Thebuilt-in flow pressure controller(gas bubble with gas feeding unit)compensates for fluctuations. Thefinely adjusted value is displayedin testo 314 along with the lea-kage amount.
0 to 1000 mbarTechnical data testo 314Pressure meas. range
0.1 mbarResolution±0.5 mbar; ±3% of mvAccuracy0 to 8 l/hVolume flow meas. range0.1 l/hResolution±0.1 l/h; ±5% of mvAccuracy> 5 hBattery life252 x 115 x 58 mmDimensionsApprox. 728 gWeight
Part no.
0560 3140
Pressure meter with built-in printer,from 0 mbar to +1000 mbar
testo 314
testo 314, pressure meter with built-inprinter, from -1000 mbar to +1000 mbar
Mains unit 230 V/8 V/1 A for separate useof control unit
System case incl. hose set for connectionto the gas pipe
testo 316-1, electronic gas leak detectorwith flexible measurement probe
TopSafe for testo 316, indestructible pro-tection case incl. stand, protects from dirtand impact
Leak detection spray for spraying on gaspipe, bubbles indicate leaking points
Conical test stop 1/2" for connecting testset to the gas pipe 19–32 mm
Conical test stop 3/4" for connecting testset to the gas pipe 24–44 mm
High pressure step plug 3/8" and 3/4" forconnecting test set to the gas pipe
High pressure step plug 1/2" and 1" forconnecting test set to the gas pipe
Pressure release plug
Single-valve block for blocking off thepipe
Double valve branch (brass) for con-necting 2 or more pipes, can be blockedoff separately
Test pump for generating test pressure
The complete testing system set forgas/water pipes
Zubehör Part no.Accessories
Mains unit 230 V/ 8 V/ 1 A, for instrument (European plug), for mains ope-ration and battery recharging
Gas feeding unit for testo 314, for battery-operated measurement
0554 1084
0554 3142
Hose set for connection to gas pipe with test pump and conical test plug1/2"
0554 3141
Single-pipe counter cap, connects test fittings to pipe 0554 3156
testo 316-1, Electronic gas leak detector with flexible measurement probeand battery
0632 0316
Two-valve branch (brass) to connect 2 or more pipes, can be blocked offseparately
0554 3161
Single-valve stop to block off pipe 0554 3162LW 6 connection hose, To connect T-fitting/single-pipe counter cap or forextension purposes
0554 3158
Conical test stop 1/2" for connecting test set to the gas pipe 19–32 mm 0554 3151
Conical test stop 3/4" for connecting the test set to the gas pipe 24-44mm
0554 3155
Conical test stop 1" to connect test fittings to gas pipe 35–65 mm 0554 3152
High pressure stage stop 3/8" and 3/4", To connect test fittings to gas pipe 0554 3163
High pressure stage stop 1/2" and 1", To connect test set to gas pipe 0554 3164
Leak detection spray for spraying on the gas pipe, shows leaking pointswhere bubbles form
0554 3166
Spare thermal paper for printer (6 rolls) 0554 0569
Test pump to produce test pressure 0554 3157Pressure set for gas pressure measurement on heating systems 0554 0449
0516 0189
System case with hose set, test pump and conical test plug 1/2"
TopSafe for testo 316, protection case incl. stand, protects from dirt andimpact
0516 3140
0554 3332
RS232 cable, connects instrument to PC (1.8 m) for data transfer
Analysis software, shows measurement in form of diagrams, tables andmanages customer data
0409 0178
High-pressure probe up to 25 bar 0638 1743
Pipe wrap probe for pipes with diameter of up to 2", for flow/return temp.meas. in hydronic systems
0600 4593
Quick-action surface probe with sprung thermocouple strip, measuringrange short-term to +500°C
0604 0194
Cable, 1.5 m long, connects probe with plug-in head to meas. instrument 0430 0143
Pressure release plug 0554 3171ISO calibration certificate/flow in gases, 5 measurement points 0520 0084
Part no.
0563 3140 70
Additional information at www.testo.comwww.testo.com10
Additional information at www.testo.comwww.testo.com 11
Notes
Temperature-compensated (tempera-ture fluctuations do not have any influ-ence on the measurement result)
11 different meas. units to select from
Measures leak rate (pressure dropover time)
Min/Max value
Hold button
Data memory for single values or se-ries of measurements
Auto-Off/Low Bat display
With precision certificate
Additional information at
Configuration modes
One touch zero
Hold button
www.testo.comwww.testo.com
Highly Accurate Pressure Meters for Industrial Applicationstesto 525
Temperature fluctuations do nothave any influence on measure-ments taken using testo 525 onaccount of temperature compen-sation. It facilitates measurementsin the ranges of positive/negativeoverpressure and absolute pres-sure making testo 525 the idealreference measuring instrumentfor calibration.
testo 525, pressure meters incl. bat-tery and calibration protocol. Seebelow for the different instrumentversions available for every applica-tion.
Accuracy ±0.2% of fsv
testo 525 Positive pressure meters
Part no.Meas. range Resolution Overload
Accuracy ±0.2% of fsv
testo 525 Absolute pressure meters
Part no.Meas. range Resolution Overload
Accuracy ±0.1% of fsvPart no.Meas. range Resolution Overload
Accuracy ±0.05% of fsvPart no.Meas. range Resolution Overload
12
0 to 30 bar 0.01 bar 70 bar 0560 5258
0 to 1100 hPa 0.1 hPa ±3000 hPa 0560 52560 to 2000 hPa 0.1 hPa ±3000 hPa 0560 5257
0 to 1100 hPa 0.1 hPa ±2000 hPa 0560 52660 to +2000 hPa 0.1 hPa ±3000 hPa 0560 5267
0 to +2000 hPa 0.1 hPa ±3000 hPa 0560 5273
Additional information at www.testo.comwww.testo.com 13
Transport and Protection
Additional accessories and spare parts
Calibration certificates
Configuration settings in instrumentAll of the important parameters in the in-strument can be easily adapted on yourPC using the PC software for testo 525;regardless of whether you wish tochange a unit or measuring rate or wishto activate smoothing. No problem. Sim-ply select the required value using thepull-down menu and it is transmitted toyour instrument straightaway.
Readout memoryData is transferred to a file on your harddisk, where it is permanently filed, whenthe “Readout memory” button is pres-sed. The data can also be shown in atable. Important information such maxi-mum/minimum and mean value appearin the top lines. The data can also beprinted or transferred to Excel.
Online Measurement All of the measurement data can be readstraightaway from the graphic appearingin the initial screen. The data is automa-tically saved during online measurement.
High speed testo 525 carries out 10/20 measure-ments per second. Fast measurement isnecessary so that pressure drops can berecognised and recorded. In the case ofhigh speed measurements, the user canselect when the measurement is to bestarted.
The following can be selected: immediatelyMeasurement starts running ad hocOvershootingMeasurement starts once a specific limitvalue is overshot UndershootingMeasurement starts once a specific limitvalue is undershot.
A trigger mode can also be set up. If alimit value is exceeded, you can deter-mine how long afterwards measure-ments can continue. Recording stopsonce the specified time has been rea-ched. If the limit value is again exceeded,recording begins again. This mode isideal for troubleshooting systems.
-5 to +50 °C-30 to +85 °C
9V block battery
984
All non-corrosive gases
Piezoresistive pressuresensor
11 different measuringunits can be set:bar, mbar, kPa, hPa, MPa,mmH2O, mH2O, mmHg,psi, inchH2O, inchHg
Manually, 1 second...60min selectable
Battery typeMeasuring medium
Hose 4 mm (to 7 bar)NPT 1/8" (from 10 bar)
Conn.
IP54
30 to 95 %RH
LCD, 1 line
RS232 interface
Protection class
Oper. temp.Storage temp.
See opposite page for information onaccuracies, measurement ranges, re-solution and overload.
152 x 83 x 34 mm
2 years270 g
Dimensions
50 hBattery life
WarrantyWeight
testo 525
Zubehör Part no.Accessories
Common data
Technical data
9V rech. battery for instrument, instead of battery 0515 0025
Recharger for 9V rechargeable battery, for external recharging of 05150025 battery
0554 0025
Adapter 1/8", for connection hoses 0554 5200
Connection hose, silicone, 5m long, max. load 700 hPa (mbar) 0554 0440
Connection hose set, 2 x 1 m, coiled, incl. 1/8" screw connection, pressure-tight up to 20 bar, outer diamter 6.3 mm, inner diameter 4.8 mm
0554 0441
Calibration pump, positive pressure , Max. 5 bar 0554 5252
Pressure transmitter 0 to 10 bar, to measure pressure in liquid substances 0554 5254
Connection hose for pressure transmitter to system (1 off) 0554 3170
ISO calibration certificate/Pressure, Differential pressure, accuracy á 0.1 (%of full scale value)
0520 0035
DKD calibration certificate/pressure, diff. and pos. pressure; 11 measuringpoints distributed over the instr. meas. range
0520 0215
Technical data / Accessories
Display
Oper. humidity
Sensor
PC
Other features
Saving interval
Memory
Case made of leather with shoulder strap, For secure storage of measuringinstrument
0554 5251
Transport case (plastic) for measuring instrument and accessories, For safetransport
0516 5200
Software and accessoriesSoftware set incl. RS232 data transfer cable, Software for instrument controland data management
0554 5256
Software, for instrument control and data management
Software for instrument control and data manage-ment
0554 5255
Data transfer cable RS 232, Connects measuring instrument to PC for datatransfer
0554 5250
DKD calibration certificate/Pressure, Absolute pressure 11 points distributedover the whole measuring range (less than 0.1% of fsv)
0520 0222
Fast-action coupling con-nections M8x0.5
(testo 526 only)
2 line displaywith text menuguide
Zeroing button
HOLD/MAX/MIN/MEAN
Prints
Saves
Display light
Additional information at
2 user defined probe sockets for pres-sure, temperature, current/voltage
Data communi-cation with PC
Built-in differential pressure probe
Mains socket/fastbattery recharging
www.testo.comwww.testo.com
Reference pressure meters for all measurement rangestesto 521
testo 521-1/-2 with internal sen-sor 0 to 100 hPa / 0.1 %testo 521-1/-2 is equipped for ac-curate differential pressure mea-surements in the VAC sector, forexample pressure drops in filters,inspections on ventilators andsuction systems. Use testo 521-1/-2 for Pitot tube measurementsin the range 5 to 100 m/s.
testo 521-3 with internal sensor 0to 2.5 hPaEven the smallest differential pres-sures up to 2.5 hPa are measuredusing testo 521-3. A high accu-racy level and a resolution of 0.1Pa make the instrument ideal formeasurements in cleanrooms orfor flue draught inspections. Usetesto 521-3 for accurate measu-rements during Pitot tube measu-rements in the range 1 to 20 m/s.
Part no.
0560 5210
testo 521-1, differential pres-sure meter 0 to 100 hPa incl. batteryand calibration protocol
0 ... 100 hPa / ±0.2 % of fsv
0 to 100 hPa / ±0.1 % of fsv
0 to 2.5 hPa
testo 526
testo 526-1 with internal sensor0 to 2000 hPa / 0.1% testo 526 is the ideal differentialpressure meter for industrial appli-cations. Processes can be accu-rately measured and monitoredwith an accuracy of 0.1% of thefull-scale value.
testo 526-2 with highly accurateinternal sensor 0 to 2000 hPa,0.05%testo 526 is the ideal differentialpressure meter for sensitive in-dustrial applications. Critical pro-cesses can be efficientlymeasured and monitored at anaccuracy of up to 0.05% of thefull-scale value.
Pressure testSpecially for leak tests on contai-ners, uninterrupted recording ispossible via the built-in test menuin testo 526-1 and testo 526-2.Subsequent processing of mea-surement data via software orprintouts ensure that the pressuretest is documented.
14
1
Part no.
0560 5211
testo 521-2, differential pres-sure meter 0 to 100 hPa incl. batteryand calibration protocol
2
Part no.
0560 5280
testo 526-1, differential pres-sure meter 0 to 2000 hPa incl. fastcoupling connections, battery andcalibration protocol
0 to 2000 hPa/ ±0.1 % of fsv
0 to 2000 hPa/ ±0.05 % of fsv
4
Part no.
0560 5281
testo 526-2, differential pres-sure meter 0 to 2000 hPa incl. fastcoupling connections, battery andcalibration protocol
5
Part no.
0560 5213
testo 521-3, differential pres-sure meter 0 to 2.5 hPa, battery andcalibration protocol included
3 The differential pressure sensor is builtinto testo 521 and testo 526. Up to twoadditional probes can be connected viauser-defined probe sockets.• Differential pressure probes to 2000
hPa• Absolute pressure probes to 2000
hPa• Relative pressure probes to 400 bar• Temperature probes from -200 to
+1250 °C • Probes for measuring cur-
rent/voltage
Wide selection of probes
• Measurement protocols can be prin-ted on site. No awkward cables requi-red on account of the infraredinterface.
• Long-term legible thermal paper en-sures that measurement data docu-mentation can be stored for up to 10years.
Documentation on site
• The saved measurement data can beeasily analysed and processed usingthe software available.
• Readings are taken by the instrumentand can be depicted online by thesoftware.
• Pressure drops can be protocolledonline in cycles of 0.05 seconds in the
Fast Measurement menu. Since, inmost cases, pressure drops cannotbe predicted, a rule can be definedvia the trigger function; the pressuredrops are then filtered out and storedseparately for the user in indexedpages.
Easy data management via PC
All transmitters or non-Testo probes (in 2or 4 wire systems, 18 V) can be con-nected to the 4 to 20 mA interface. Sca-ling is carried out on the hand-heldmeasuring instrument.
Major benefit: The transmitter connecteddoes not need its own power; it is sup-plied by the testo 521 or testo 526 pres-sure meter.
Inspection of transmitters with 4 to 20 mA interface
• Measurement data can be saved se-parately or as a measurement series.The measurement rate (0.04 seconds,1 second to 24 hours) and the num-ber of values to be saved are freelyselectable. The maximum memorysize is 25,000 readings.
• The readings are saved under sepa-rate names for the sites (max. 99sites) - with retracing guarantee.
• Online measurement for large quanti-ties of data can be activated via PC.
Long-term monitoring made easy
Ceramic sensor for ex-ternal pressure probes
Piezoresistive pressure sensorFor external pressure probes
NTC Type K (NiCr-Ni) Voltage measurement Current measurement
Piezoresistive pressuresensor
Piezoresistive pressuresensor
Piezoresistive pressuresensor
Probe type Piezoresistive pressuresensor
Piezoresistive pressuresensor
Additional information at www.testo.comwww.testo.com 15
Transport and Protection
Printer and accessories
Additional accessories and spare parts
Software and accessories
Calibration certificates
0 to +50 °C-20 to +70 °C
9 V (6LR61)Battery type
Hose: inner Ø 4 mmouter Ø 6 mm
LCD display with symbol, 7 segment display andpoint matrix
ABSRS232 interface
Mains connection and batteryrecharging in instrument
Automatic recognition of allconnected probes
9 measurement units selecta-ble: mbar, hPa, bar, Pa, kPa,inH2O, mmH2O, torr, psi100 kB (corresponds to
approx. 25,000 readings)
Battery/Rechargeablebattery,Mains unit 12 V
Oper. temp.Storage temp. 219 x 68 x 50 mm
2 years300 g
Dimensions
Continuous operation w/internal pressure sen-sor: 30 hWith rech. battery: 10 hWith carbon battery: 18h
Battery life
WarrantyWeight
Accessories / Technical datatesto 521 / testo 526
Common data testo 521 / testo 526
Conn.
Display
from 0.04 secondsMeasuring rate
±1 digit
0.01 bar
-1 to 400 bar
Resolution
±0.2 % of fsvAccuracy*Meas. range
0.1 Pa (0638 1347)0.001 hPa (0638 1447)0.01 hPa (0638 1547)0.1 hPa (0638 1647; 06381747; 0638 1847)
0 to 2000 hPa±0.1 % of mv
0.1 °C
-40 to +150 °C±0.2 °C (-10 to +50 °C)±0.4 °C (remaining range)
0.1 °C
-200 to +1370 °C±0.4 °C (-100 to +200 °C)±1 °C (remaining range)
0.01 V
0 ... 10 V±0.01 V
0.01 mA
0 to 20 mA±0.04 mA
Material/HousingPC
Other featu-res
Memory
Power supply
2x per second, in fastmeasurement 4x per se-cond
Updating rate in dis-play
0.01 hPa
0 ... 100 hPa
Resolution
Meas. range
testo 521-1 testo 521-2 testo 521-3
Technical data
0.01 hPa
0 to 100 hPa
2000 hPaStatic pressure 2000 hPa 100 hPa300 hPaOverload 300 hPa 50 hPa
0.1 Pa
±0.2 % of fsvAccuracy ±0.1 % of fsv ±0.5 Pa (0 to 20 Pa)±(0.5 Pa ±0.5% of mv)(20.1 to 250 Pa)
0 to 2.5 hPa
±1 digit
0.1 hPa
0 to 2000 hPa
testo 526-1 testo 526-2
0.1 hPa
0 to 2000 hPa
2000 hPa 2000 hPa3000 hPa 3000 hPa
to 2,5 hPaZeroing to 2,5 hPa to 0,5 hPa to 50 hPa to 50 hPa
±0.1 % of fsv ±0.05 % of fsv
*Accuracy information applies only to instrument without probes connected
Zubehör Part no.Accessories Zubehör Part no.Accessories
TopSafe (protection case), incl. carrier strap, bench stand and magnet. Pro-tects instrument from dust, impact, scratches
0516 0446
Transport case, for measuring instrument, probes, Prandtl Pitot tube, acces-sories
0516 0527
System case, For measuring instrument, probes, straight or Prandtl Pitottube, accessories
0516 0526
Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4AA batteries, for printing out measurements on site
0554 0549
External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batterieswith individual cell charging and charge control display, incl. impulse tricklecharging, integrated discharge function, with built-in international mainsplug, 100-240 V, 300 mA, 50/60 Hz
0554 0610
Spare thermal paper for printer (6 rolls) 0554 0569Spare thermal paper for printer (6 rolls), permanent ink, measurement datadocumentation legible for up to 10 years
0554 0568
ComSoft 3 - Professional with data management, incl. database, analysisand graphics function, data analysis, trend curve
0554 0830
RS232 cable, connects instrument to PC (1.8 m) for data transfer 0409 0178
Ethernet adapter, RS232 - Ethernet incl. software driver, mains unit,facilitates data communication in network
0554 1711
9V rech. battery for instrument, instead of battery 0515 0025Recharger for 9V rechargeable battery, for external recharging of 05150025 battery
0554 0025
Desk-top power supply with international connection options 0554 1143 DKD calibration certificate/Pressure, Differential pressure, accuracy á 0.1(% of full scale value)
0520 0205
DKD calibration certificate/pressure, differential pressure, accuracy 0.1 to0.6 (% of full-scale value)
0520 0215
DKD calibration certificate/pressure, differential pressure, accuracy > 0.6 (%of full-scale value)
0520 0225
DKD calibration certificate/pressure, absolute pressure, accuracy 0.1 to 0.6(% of full-scale value)
0520 0212
ISO calibration certificate/Pressure, Differential pressure, accuracy á 0.1 (%of full scale value)
0520 0035
ISO calibration certificate/pressure, differential pressure, accuracy 0.1 to 0.6(% of fsv)
0520 0025
ISO calibration certificate/pressure, Differential pressure, accuracy > 0.6 (%of fsv), for testo 521-3
0520 0005
ISO calibration certificate/Pressure, Differential pressure, accuracy > 0.1 (%of fsv), for testo 521-2
0520 0405
ISO calibration certificate/absolute pressure, 5 measurement points distribu-ted over meas. range, absolute pressure, accuracy 0.1 to 0.6 (% of fsv)
0520 0125
ISO calibration certificate/temperature, for air/immersion probes, calibrationpoints -18°C; 0°C; +60°C
0520 0001
ISO calibration certificate/temperature, Meas. instr. with air/immersionprobe; cal. points 0°C; +150°C; +300°C
0520 0021
ISO calibration certificate/temperature, meas. instr. with surface probe; cali-bration points +60°C; +120°C; +180°C
0520 0071
DKD calibration certificate/temperature, meas. instr. with air/immersionprobe; calibration points -20°C; 0°C; +60°C
0520 0211
DKD calibration certificate/temperature, contact surface temperature probes;calibration points +100°C; +200°C; +300°C
0520 0271
ISO calibration certificate/electrical 0520 1000
Additional information at www.testo.comwww.testo.com
Probes / Accessoriestesto 521 / testo 526
16
Precision pressure probe, 100 Pa, in robust metalhousing with impact protection, incl. magnet forfast attachment, to measure differential pressureand flow speeds (in combination with Pitot tube)
0638 1347
Conn.: Plug-in head. connection cable0430 0143 or 0430 0145 required
Conn.: Plug-in head. connection cable0430 0143 or 0430 0145 required
Conn.: Plug-in head. connection cable0430 0143 or 0430 0145 required
Conn.: Plug-in head. connection cable0430 0143 or 0430 0145 required
Conn.: Plug-in head. connection cable0430 0143 or 0430 0145 required
Conn.: Plug-in head. connection cable0430 0143 or 0430 0145 required
0 to +100 Pa to 20 Pa±(0.3 Pa ±0.5% of mv)
Oper. temp.0 to +50 °C (compensated)
Oper. temp.0 to +50 °C (compensated)
Oper. temp.0 to +50 °C (compensated)
Oper. temp.0 to +50 °C (compensated)
Oper. temp.0 to +50 °C (compensated)
Oper. temp.-40 to +100 °C0 to +70 °C (compensated)
Oper. temp.-40 to +100 °C0 to +70 °C (compensated)
Oper. temp.-40 to +100 °C0 to +70 °C (compensated)
Oper. temp.-40 to +100 °C0 to +70 °C (compensated)
Oper. temp.-40 to +100 °C0 to +70 °C (compensated)
Oper. temp.0 to +50 °C
Conn.: Plug-in head, connection cable 0409 0202 required
Conn.: Plug-in head, connection cable 0409 0202 required
Conn.: Plug-in head, connection cable 0409 0202 required
Conn.: Plug-in head, connection cable 0409 0202 required
Conn.: Plug-in head, connection cable 0409 0202 required
Pressure probe, 10 hPa, in robust metal housingwith impact protection incl. magnet for fast at-tachment, to measure differential pressure andflow speeds (in combination with Pitot tube)
0638 14470 to +10 hPa ±0.03 hPa
Pressure probe, 100 hPa, in robust metal housingwith impact protection, incl. magnet for fast at-tachment, to measure differential pressure andflow speeds (in combination with Pitot tube)
0638 15470 to +100 hPa ±0.5% of mv (+20 to+100 hPa)±0.1 hPa (0 to +20 hPa)
Pressure probe, 1000 hPa, measures differentialpressure, in robust metal housing with impactprotection, incl. quick-closing coupling (M8 x0.5), magnet for fast attachment
0638 16470 to +1000 hPa ±1 hPa (0 to 200hPa)±0.5% of mv (200 to1000 hPa)
Pressure probe, 2000 hPa, measures differentialpressure, in robust metal housing with impactprotection, incl. quick-closing coupling (M8 x0.5), magnet for fast attachment
0638 17470 to +2000 hPa ±2 hPa (0 to 400hPa)±0.5% of mv (400 to2000 hPa)
Meas. range AccuracyIllustration Zeroing
100 hPa
Static pres-sure
50 hPa
to 0,4 hPa1000 hPa50 hPa
to 4 hPa1000 hPa300 hPa
to 20 hPa1000 hPa2000 hPa
to 40 hPa
to 0,1 bar
to 0,3 bar
to 0,4 bar
to 1 bar
to 4 bar
1000 hPa3000 hPa
——4000 hPa
OverloadDifferential pressure probe Part no.
Meas. range AccuracyIllustration ZeroingStatic pres-sure
Overload Part no.
Pressure probe, 2000 hPa, measures absolutepressure, in robust metal housing with impactprotection, incl. quick-closing coupling (M8 x0.5), magnet for fast attachment
0638 18470 to +2000 hPa ±5 hPa (0 to+2000 hPa)
Absolute pressure probe
Low pressure probe, refrigerant-proof stainlesssteel, up to 10 bar
0638 1741-1 to +10 bar ±1% of fsv 25 bar
High pressure probe, refrigerant-proof stainlesssteel, up to 30 bar
0638 1841-1 to +30 bar ±1% of fsv 120 bar
High pressure probe, refrigerant-proof stainlesssteel, up to 40 bar
0638 1941-1 to +40 bar ±1% of fsv 120 bar
High pressure probe, refrigerant-proof stainlesssteel, up to 100 bar
0638 2041-1 to +100 bar ±1% of fsv 250 bar
High pressure probe, refrigerant-proof stainlesssteel, up to 400 bar
0638 2141-1 to +400 bar ±1% of fsv 600 bar
Meas. range AccuracyIllustration OverloadRelative pressure probe (media compa-tible)Part no.Zeroing
Additional information at www.testo.comwww.testo.com 17
Probes / Accessoriestesto 521 / testo 526
Current/voltage cable (±1 V, ±10 V, 20 mA) 0554 00070 to +1000 mV0 to +10 V0 to +20 mA
±1 mV (0 to +1000 mV)±0.01 V (0 to +10 V)±0.04 mA (0 to +20 mA)
4 to 20 mA interface for connection and intermittent power supply to transmitters(scaling via hand-held instrument), in robust metal housing with impact pro-tection, incl. magnet for fast attachment
0554 05280/4 to 20 mA
Channels 1 channel, transmitter connection via termi-nal board
Auxiliary energy output 18V DC ± 20%max. connection load 30 mA
±0.04 mA
Conn.: Plug-in head. connectioncable 0430 0143 or 0430 0145 re-quired
Meas. range Conn.AccuracyIllustrationCurrent/voltage probes Part no.
Pitot tube, 350 mm long, Ø 7 mm, stainless steel, measures flow speed Inconjunction with 0638 1347 / 0638 1447 / 0638 1547 pressure probesor testo 521, with internal sensor
0635 21450 to +600 °COper. temp.IllustrationPitot tubes Part no.
Meas. range AccuracyIllustrationTemperature probes t99 Part no.150 mm
350 mm
Ø 7
mm
Pitot tube, 500 mm long, Ø 7 mm, stainless steel, measures flowspeed In conjunction with 0638 1347 / 0638 1447 / 0638 1547 pres-sure probes or testo 521, with internal sensor
0635 20450 to +600 °C500 mm
Ø 7
mm
Ø 10 mm
Quick-action surface probe with sprung thermo-couple strip, measuring range short-term to+500°C
0604 0194-200 to +300 °C Class 2* 3 s
Conn.: Plug-in head. connection cable 0430 0143 or 0430 0145 required
Pipe wrap probe for pipes with diameter of up to2", for flow/return temp. meas. in hydronic sys-tems
0600 4593-60 to +130 °C Class 2* 5 s
Conn.: Fixed cable
150 mm
Ø 1.5 mm
Super quick-action immersion/penetration probefor measurements in liquids
0604 0493-200 to +600 °C Class 1* 1 s
Conn.: Plug-in head. connection cable 0430 0143 or 0430 0145 required
150 mm
Ø 9 mm
Highly accurate air probe for air and gas tempe-rature measurements with bare, mechanicallyprotected sensor
0610 9714-40 to +130 °C To UNI curve 60 s
Conn.: Fixed cable
Zubehör Part no.AccessoriesCable, 1.5 m long, connects probe with plug-in head to meas. instrument,PUR coating material
0430 0143Zubehör Part no.Accessories
Cable, 5 m long, connects probe with plug-in head to measuring instrument,PUR coating material
0430 0145
Connection hose, silicone, 5m long, max. load 700 hPa (mbar) 0554 0440
Connection hose set, 2 x 1 m, coiled, incl. 1/8" screw connection, pressure-tight up to 20 bar, outer diamter 6.3 mm, inner diameter 4.8 mm
0554 0441
Connection cable, 2.5 m long, for pressure probes 06381741/1841/1941/2041/2141
0409 0202
Adapter for pressure probes, 1/2" outer thread, 1/4" inner thread, for pres-sure probes 0638 1741/1841/1941/2041/2141
*According to standard EN 60584-2, the accuracy of Class 1/2 refers to -40 to +1000/+1200 °C
0699 3127
Additional information at18
Leakage Detector for Refrigerants
3 g/a
R134a, R22, R404a, H2and all common refrige-rants such as CFC, HCFC,HFC NH³ (separate sen-sor head)
g/a
optical and audible alarm
<á1 s
testo 316-4 Set 1 the fast andreliable leakage detector for allcommon refrigerants
testo 316-4 Set 2 specially forammonia.
The sensor is permanently moni-tored and shows malfunctions orcontamination in the display. Theuse of test leaks is thus no longernecessary. If dirty, the sensor canbe easily cleaned and is immedia-tely ready for use again.
When leaks are detected, the dis-play changes from green to red.An audible signal additionally in-forms of leakages detected.Using the earplug, the testo 316can also be used in loud surroun-dings. The maximum indicatorfunction shows maximum leaka-ges and so facilitates the identifi-cation of leakage locations. Theflexible gooseneck allows the op-timum positioning of the sensorclose to the piping or the leakagelocation.
A simple change of sensor by theuser turns the 316-4 into an am-monia detector.
testo 316-4Very long sensor life
Optical and audible alarm
Permanent sensor check
Easy sensor change by the user
Earplug socket for secure localization ofleakages in loud surroundings
Maximum indicator shows maximumleakages
Technical data
www.testo.comwww.testo.com
Zubehör Part no.Accessories
lower reaction thres-hold
Detectable
Leakage alarm
Meas. parameter
Reaction time
Spare head for refrigerants (CFC, HCFC, HFC, H2) 0554 3180
Spare head for ammonia (NH³) 0554 3181
Part no.
0563 3164
Set 1 consisting of testo 316-4, sen-sor head refr. (CFC, HCFC, HFC, H2),case, mains charging unit, earplug)
Leakage detector for refrigerants
Part no.
0563 3165
testo 316-4 Set 2
Set 2 consisting of testo 316-4, sen-sor head NH³, case, mains chargerunit, earplug
Dimensions 190 x 57 x 42 mmWeight 348 g
Oper. temp. -20 to +50 °COper. humidity 20 to 80 %RHStorage temp. -25 to +70 °C
Complies with:
Length of gooseneck 370 mm
Power supply 1 battery block (6 cellsNiMh)
Battery life 6 h (Continuous opera-tion)
Warranty
1g/year sensitivity acc. toEN 14624 and E 35-422
24 months (instrumentand sensor)
Start-up time <á50 s(0 to +50 °C)á80 s(-20 to 0 °C)
Detectable refrigerantsRefrigerantsRefrigerants group
Reference refrige-rant(Lower response threshold specified)
Refrigerantdetectable
Refrigerant selectionin instrument
CFC
H-CFC
H-HFC
R12
R22
R123
R134a
R404
R407a, b, c, d, e
R408
R409
R410a
R505
R507
R600/R600a
Hydrogen
Ammonia
R410a
R124
R227
R422d
R11
R290
R508
R427a
R1270
R1150
R170
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
R22
R22
R404a
R22
R22
R22
R134a
R404a
R134a
R22
R22
R134a
R22
R134a
R22
H2
NH³
R134a
R22
R134a
R134a
R22
H2
R134a
R404a
R22
R22
R134a
Additional information at www.testo.comwww.testo.com 19
Electronic manifoldtesto 523
• Calculation of superheating and sub-cooling in real time
• Display and sightglass illumination
• 2-way valve block
• 1 temperature probe socket
• 30 refrigerants stored in instument
• Interface to the wireless report printer(optionally available)
• Stowable carabiner hook for easysuspension of the instrument
The electronic manifold is used tocalculate superheating and sub-cooling in a refrigeration system.The pressures measured with thetwo pressure sensors are imme-diately converted into temperaturevalues, depending on the refrige-rant selected, and displayed on alarge, backlit display.
Technical data
Part no.
0560 5231
testo 523, electronic refrigerationsystem analyser, brass connections,calibration protocol and batteriesincluded
Part no.
0563 5234
testo 523 refrigeration system ana-lyser, Velcro surface probe
testo 523 Set 1
Part no.
0563 5235
testo 523 refrigeration system ana-lyser, Velcro surface probe, incl.transport case
testo 523 Set 2
Part no.
0563 5236
Refigeration system analyzer testo523, pipe clamp probe for pipe dia-meters 5 to 65, transport case forinstrument and accessories
testo 523 Set 3
Part no.
0563 5237
Refigeration system analyzer testo523, pipe clamp probe for pipe dia-meters 5 to 65, Testo report printer,spare thermal paper (6 rolls), trans-port case for instrument and acces-sories
testo 523 Set 4
Meas. range
Meas. range
Overload
Accuracy
Accuracy
±1 digit
Conn.
Resolution
Oper. temp.Storage temp.
Battery lifeDimensions
Battery type
Protection classWeight
25 bar / 50 bar50 bar / 100 bar
-100 to +200 °CClass B ±(0,3 +0,005 tl)0.1 °C
CFC, HFC, N, H2O, CO2
-20to +60 °C-20to +60 °C
40 h (no light)4 AA batteries
260 x 130 x 70 mmIP54
3 x 7/16" UNF
Resolution 0.1 bar
1250 g
1 x plug-in
±0.5% fs (Class 0.5)
General technical data
Temperature
Low pressure/High pressure
Probe connections
Pressure media
R12R1270R134aR22R23
R290R401AR401BR401CR402A
R402BR403BR404AR406AR407A
R407BR407CR407DR408AR409A
R410AR413AR414BR417AR422D
R500R502R507R744R718
Refrigerants permanently stored in instrument
Probes and Accessories on page22
Additional information at www.testo.comwww.testo.com20
Electronic refrigeration system analyser with data managementtesto 556
• On-site printout on Testo printer (optional)
• High-quality sensors measure high/low pressure and temperature
• Calculation of superheating and subcooling in real time
• 4-way valve block with sight glass
• 4 temperature probe sockets
(2 x wireless, 2 x wire connection)
• Wireless temperature measurement up to 20 m distance (withoutobstruction)
• 30 refrigerants are stored in the instrument, more refrigerants canbe downloaded free of charge from the Testo website using “Easy-Kool” software
• 60,000 readings can be stored
• Additional functions (not included in delivery):- Current measurement- Stock management of refrigerants when filling and evacuating re-frigeration systems- Connection of refigerant scales- Oil pressure measurement
The refrigeration system analyser,with 4-way valve block and 2pressure sensors included, calcu-lates superheating and subcoo-ling in a refrigeration system orheat pump using externally atta-chable probes. The flow paths ofa system can be temporarilychanged with the 4-way valveblock.
Convenient data management ona PC with "EasyKool" software.
Technical data testo 556 / testo 560
Part no.
0560 5563
testo 556-1, electronic refrigerationsystem analyser, brass connections,calibration protocol and batteriesincluded
Part no.
0560 5564
testo 556-2, electronic refrigerationsystem analyser, stainless steelconnections, calibration protocoland batteries included
Part no.
0563 5561
testo 556-1refrigeration system ana-lyzer, Velcro surface probe, soft-ware with USB data cable, mainsunit, lock to secure analyzer, systemcase for extensive accessories in-cluded
testo 556-1 Set
Part no.
0563 5562
testo 556-2 refrigeration systemanalyser, Velcro surface probe, soft-ware with USB data cable, mainsunit, lock to secure analyser, NH3adapter, system case for extensiveaccessories included
testo 556-2 Set
Meas. range
Meas. range
Overload
Accuracy
Accuracy
±1 digit
Conn.
Resolution
Oper. temp.Storage temp.
Battery lifeDimensions
Battery type
Protection classWeight
25 bar / 50 bar50 bar / 100 bar
Resolution 0,1 bar
Resolution 0,1 mbar
-100 to +200 °CClass B ±(0,3 +0,005 tl)0.1 °C
CFC, HFC, N, H2O, CO2
-20to +60 °C-20to +60 °C
40 h (no light)4 AA batteries
260 x 130 x 70 mm
IP54
3 x 7/16" UNF1 x 5/8" UNF
1400 g
Data store in instru-ment
60,000 readings
In the case of testo 556 and testo 560, additionalrefrigerants can be downloaded free of chargeusing the Testo website and "EasyKool software".
* only testo 556-1 / 560-1 (brass)** only testo 556-2 / 560-2 (stainless steel)
2 x plug-in (Pt100)2 x wireless (TC)
±0.5% fs (Class 0.5)
General technical data
Temperature
Meas. range 0 to 200 hPa3 bar*
Vacuum
Low pressure/High pressure
Probe connections
Pressure media
R-12R1270R134aR22R23R290
R401AR401BR401CR402AR402BR403B
R404AR406a*R407AR407BR407CR407D
R408AR409AR410AR413AR414b*R417A
R422a*R500R502R507R508**R717**
R723**R744R718
Refrigerants permanently stored in instruments
Overload
*Sensor protected from high pressures
Additional information at www.testo.comwww.testo.com 21
Electronic refrigeration system analyser with data managementand vacuum sensortesto 560
• Vacuum sensor/Evacuation
• The sensor measures absolute pressure and displays the corresponding evapora-tion temperature of water.
• The vacuum cell is protected from high pressures by a special valve.
• On-site printout on Testo printer (optional)
• High-quality sensors measure high/low pressure and temperature
• Calculation of superheating and subcooling in real time
• 4-way valve block with sight glass
• 4 temperature probe sockets
(2 x wireless, 2 x wire connection)
• Wireless temperature measurement up to 20 m distance (without obstruction)
• 30 refrigerants are stored in the instrument, more refrigerants can be downloadedfree of charge from the Testo website using “EasyKool” software
• 60,000 readings can be stored
• Additional functions (not included in delivery):- Current measurement- Stock management of refrigerants when filling and evacuating refrigeration sys-tems- Connection of refigerant scales- Oil pressure measurement
"EasyKool" software manages all custo-mer addresses, systems and individualcustomer and system information. Thedata recorded relating to repairs, leaktests or evacuations in refrigeration sys-tems can therefore be easily allocated tocustomers. The most important data such as custo-mer address, system, refrigerants anddate are automatically fed into tables orgraphs.
Managing refrigerants and downloadingnew refrigerantslPC software lists all of the available refri-gerants. Additional refrigerants can bedownloaded at any time to the analysersusing the Testo website and software.
Up to 40 refrigerants can be managedon testo 556 and testo 560 at any onetime. All – or the refrigerants identified inthe list by a mouse click – can be added.In this way each refrigeration systemanalyser can be individually equippedwith refrigerants.
"EasyKool" software can do even more...- Reads out and deletes memory con-
Save time and money when analysingerrorsIf the performance of a refrigeration unitslacks off or a system registers "Error", itcould be for any number of reasons: airin the refrigerant circuit, leaks in pipesand therefore loss of refrigerant, dirt inevaporators or condensers etc.
By recording the pressures and tempe-ratures measured over a longer period oftime, it is not necessary to monitor thesystem for several hours at a time. Therecorded data is analysed in the fastesttime on your PC.
testo 556 and testo 560 save all the rea-dings quickly and reliably. Electronic refri-geration system analysers can store over60,000 readings. In this way, large-scalemeasurement series lasting several dayscan be logged without any problem.
Measurement data stored in the analy-sers is transmitted to your PC using theinterface cable. The data is shown ingraph or table form.
Issuing logs for customers
The refrigeration system analyserfor all applications on refrigerationsystems and heat pumps. Themeasuring instrument with high-quality sensors for measuringpressure, vacuum and tempera-ture. Valve block for temporarilychanging the flow paths in thesystem is included.
A convenient PC software sup-ports data management: dataoverviews of all measurements,displays in table and graph form,automatic transfer of company,fitter, customer and system data.
tents of analyzer- Online measurement- Refrigerant management- Import of system data e.g. from Excel
Professional data processing with "EasyKool" softwaretesto 556 / 560
Part no.
0560 5603
testo 560-1, electronic refrigerationsystem analyser with vacuum sen-sor, brass connections, calibrationprotocol and batteries included
Part no.
0560 5604
testo 560-2, electronic refrigerationsystem analyser with vacuum sen-sor, stainless steel connections, ca-libration protocol and batteriesincluded
Part no.
0563 5602
testo 560-1 refrigeration systemanalyser, Velcro surface probe, soft-ware with USB data cable, mainsunit, lock to secure analyser, systemcase for extensive accessories in-cluded
testo 560-1 Set
Part no.
0563 5603
testo 560-2 refrigeration systemanalyser, Velcro surface probe, soft-ware with USB data cable, mainsunit, lock to secure analyzer, NH3adapter, system case for extensiveaccessories included
testo 560-2 Set Technical data see page 20
Additional information at www.testo.comwww.testo.com
Probestesto 523, 556, 560
Accessoriestesto 523, 556, 560
22
Meas. range AccuracyIllustrationProbes testo 523 / testo 556 / testo 560 t99 Part no.
Meas. range AccuracyIllustrationProbes testo 556 / testo 560 t99 Part no.
450 mm
20 mm
Pipe wrap probe with Velcro for pipes from Ø 6mm to Ø 120 mm, Pt 100, 2.9 m cable length
0609 5602-100 to +400 °C Class A 90 s
Zubehör Part no.Accessories testo 523 / testo 556 / testo 560Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4AA batteries
0554 0549
Robust, waterproof Pt100 immersion/penetrationprobe 0609 1273-50 to +400 °C Class A (-50 to +300 °C), Class B
(remaining range)12 s
Fixed cable 1.2 m
50 mm
Ø 3.7 mm
114 mm
Ø 5 mm
Robust, waterproof surface temperature probe,Pt100 0609 1973-50 to +400 °C Class B 40 s
Fixed cable 1.2 mØ 9 mm
114 mm
Ø 5 mm
Efficient, robust air probe, Pt1000609 1773-50 to +400 °C Class A (-50 to +300 °C), Class B
(remaining range)70 s
Fixed cable 1.2 m
50 mm
Ø 4 mm
114 mm
Ø 5 mm
Pipe wrap probe for pipe diameter 5 to 65 mm0609 5605-50 to +120 °C Class B 5 s
Fixed cable
Current probe for measuring current consumptionof compressors, with switchable measuring range 0554 56070 to 20/200 A 0 to 9.9 A 4%
10 to 49.9 A 3%50 to 200 A 2%
Fixed cable
Oil pressure probe for checking oil level in thecompressor 0638 17420 to 25 bar rel 1,5 % of fsv
Overload 50 bar
Fixed cable
Scales incl. transport case and batteries (0 to 80kg), incl. data cable, directly connectable to testo556/560, overload 120 kg, resolution: 0.01 kg
0554 5606
Spare thermal paper for printer (6 rolls), permanent ink 0554 0568
Lock for wall holder 0554 1747
External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batterieswith individual cell charging and charge control display, incl. impulse tricklecharging, integrated discharge function, with built-in international mainsplug, 100-240 V, 300 mA, 50/60 Hz
0554 0610
Scales incl. transport case and batteries (0 to 80 kg), incl. data cable, di-rectly connectable to testo 556/560, overload 120 kg, resolution: 0.01 kg
0554 5606
Transport case for measuring instrument and accessories 0516 5013
System case for measuring instrument and extensive accessories 0516 5602
Plug-in mains adapter, 5 VDC 500 mA with European adapter, 100-250 VAC,50-60 Hz
0554 0447
USB connection cable, instrument to PC 0449 0047
"EasyKool" software with measurement data management, USB data cableincluded
0554 5604
Stainless steel adapter for NH3 (ammonia), 3 connection hoses with 7/16” to1/2” and 1 connection hose 5/8" to 1/2”, hose length 24 cm
0554 5561
Zubehör Part no.Accessories testo 556 / testo 560
ISO calibration certificate relative pressure, 3 measurement points distribu-ted over the measurement range
0520 0085
ISO calibration certificate/absolute pressure, 3 meas. points distributed overmeas. range
0520 0185
ISO calibration certificate/temperature, meas. instr. with surface probe; cali-bration points +60°C; +120°C; +180°C (no wireless probes)
0520 0071
ISO calibration certificate/temperature, for air/immersion probes, calibrationpoints -18°C; 0°C; +60°C
0520 0001
Calibration for wireless probes: ISO calibration certificate/temperature, singlepoint calibration for surface thermometer; calibration point +60°C
0520 0072
ISO calibration certificate current probe, 3.5-figure 0520 3105
ISO calibration certificate/scales 0520 2620
Zubehör Part no.Calibration Certificates
Additional information at www.testo.comwww.testo.com
Option: Radiotesto 556 / 560
23
Assembled for you: Radio handles with probe head
Radio handles, separate
Radio module for upgrading measuring instrument with radio option
Radio module for measuring instrument, 869.85 MHz, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE,AT, DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO
Radio module for measuring instrument, 915.00 MHz FSK, approval for USA, CA, CL
0554 0188
0554 0190
Measuring rate 0.5 s or 10 s, adjustableon handle
Battery typeBattery life
Radio immersion/pene-tration probe, NTC
2 x 3V button cell (CR 2032) 2 AAA micro batteries150 h (meas. rate 0.5 s)2 months (meas. rate 10 s)
215 h (meas. rate 0.5 s)6 months (meas. rate 10 s)
Radio transmission
Radio coverage
Unidirectional
Oper. temp. -20 to +50 °CStorage temp. -40 to +70 °CUp to 20 m (without ob-
structions)
Meas. range Accuracy Resolution
Radio handle for attachable probe heads withT/C probe head for air and immersion/penetra-tion measurement
0602 0293
0602 0293
-50 to +350 °CShort-term to +500 °C
:±(0.5 °C +0.3% of mv) (-40 to +500 °C)±(0.7 °C +0.5% of mv) (remaining range): Class 2
0.1 °C (-50 to +199.9 °C)1.0 °C (remaining range)
0602 0394
0602 0394
Radio handles with probe head for air-/ immersion-penetration-meas.
Radio probes: General technical data
t99 (inwater)10 s
Radio freq.Country versions
Radio handle for plug-in probe heads, incl. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI,HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO
T/C probe head for air/immersion/penetration measurement, attachable to radio handle, T/C Type K
T/C probe head for air/immersion/penetration measurement, attachable to radio handle, T/C Type K
T/C probe head for surface measurement, attachable to radio handle, T/C Type K
T/C probe head for surface measurement, attachable to radio handle, T/C Type K
Radio handle for plug-in probe heads, incl. T/C adapter, approval for USA, CA, CL
0554 0189869.85 MHz FSK
915.00 MHz FSK 0554 0191
Part no.
Radio handle for attachable probe heads withT/C probe head for surface measurement
Radio handle for attachable probe headsincl. adapter for attaching T/C probes (TypeK)
-50 to +350 °CShort-term to +500 °C
:±(0.5 °C +0.3% of mv) (-40 to +500 °C)±(0.7 °C +0.5% of mv) (remaining range): Class 2
0.1 °C (-50 to +199.9 °C)1.0 °C (remaining range)
5 s
Radio freq.Country versions
Radio handle for plug-in probe heads, incl. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI,HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO
Radio handle for plug-in probe heads, incl. T/C adapter, approval for USA, CA, CL
0554 0189869.85 MHz FSK
915.00 MHz FSK 0554 0191
100 mm
Ø 5 mm
30mm
Ø 3,4mm
120 mm
Ø 5 mm
40mm
Ø 12mm
Part no.
Meas. range Accuracy ResolutionRadio handles with probe head for surface measurement
-50 to +1000 °C ±(0.7 °C +0.3% of mv) (-40 to +900 °C)±(0.9 °C +0.5% of mv) (remaining range)
0.1 °C (-50 to +199.9 °C)1.0 °C (remaining range)
Radio freq.Country versions
Radio handle for plug-in probe heads, incl. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI,HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO
Radio handle for plug-in probe heads, incl. T/C adapter, approval for USA, CA, CL
0554 0189869.85 MHz FSK
915.00 MHz FSK
869.85 MHz FSK
915.00 MHz FSK
0554 0191
Part no.
Radio freq.Country versions Part no.
Meas. range Accuracy ResolutionRadio handles for attachable T/C probes
t99
t99
Meas. range AccuracyIllustrationProbes for radio handle t99 Part no.Fast-action surface probe with sprung thermo-couple strip, also for uneven surfaces, measure-ment range short-term to +500°C, TC Type K
0602 0393-60 to +300 °C Class 2 3 s
0602 0092
Pipe wrap probe with Velcro strip, for temperaturemeasurement on pipes with diameter up to max.120 mm, Tmax +120°C, TC Type K
0628 0020-50 to +120 °C Class 1 90 s
Pipe wrap probe for pipe diameter 5 to 65 mm,with exchangeable measuring head. Meas. rangeshort-term to +280°C, TC Type K
Spare meas. head for pipe wrap probe, TC Type K
0602 4592-60 to +130 °C Class 2
Class 2
5 s
Clamp probe for measurements on pipes, pipediameter 15 to 25 mm (max. 1"), meas. rangeshort-term up to +130°C, TC Type K
0602 4692-50 to +100 °C
-60 to +130 °C
Class 2 5 s
5 s
115 mm
Ø 5 mmØ 12 mm
395 mm
20 mm
Meas. range Accuracy Resolution
0 to +100 %RH-20 to +70 °C
±2 %RH (+2 to +98 %RH)±0.3 °C
0.1 %RH0.1 °C
Radio probes incl. humidity probe head
Radio handle for attachable probe heads with humi-dity probe head
Radio handle for plug-in probe heads, incl. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT, DK, FI, HU, CZ, PL, GR, CH,PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO
Radio handle for plug-in probe heads, incl. T/C adapter, approval for USA, CA, CL
0554 0189
Humidity probe head, attachable to radio handle 0636 97360554 0191
Humidity probe head, attachable to radio handle 0636 9736
869.85 MHz FSK
915.00 MHz FSK
Radio freq. PPart no.Country versions
Testo: At Your Service
0981
702
4/m
sp/S
I/A/0
1.20
10S
ubje
ct to
cha
nge
with
out n
otic
e.
Please send for more information:
Monitoring Instruments for Food Production, Transport and Storage
Measurement Engineering for Restaurants, Catering and Supermar-kets
Measurement Engineering for Air Conditioning and Ventilation
Measurement Engineering for Heating and Installation
Measurement Solutions for Emissions, Service and Thermal Pro-cesses
Measurement Solutions for Refrigeration Technology
Stationary Measurement Solutions for Air Conditioning, Drying, Cle-anrooms and Compressed Air
Measurement Solutions for Production, Quality Control and Main-tenance
Measurement Solutions for Climate Applications in Industry
Reference Measurement Technology for Industry
Measuring Instruments For Temperature
Measuring Instruments for Humidity
Measuring Instruments For Velocity
Measuring Instruments for Pressure and Refrigeration
Multi-Function Measuring Instruments
Measuring Instruments for Flue Gas and Emissions
Measuring Instruments for RPM, Analysis, Current/Voltage
Measuring Instruments For Indoor Air Quality, Light And Sound
Stationary Measurement Technology Humidity / Differential Pres-sure / Temperature / Process Displays
Stationary Measurement Technology Compressed Air Humidity /Compressed Air Consumption