Expanded Size,Expanding Patient Options The only TAVI solution for larger anatomies

World HeadquartersMedtronic, Inc.710 Medtronic ParkwayMinneapolis, MN 55432-5604USATel: (763) 514-4000Fax: (763) 514-4879Medtronic USA, Inc.Toll-free: 1 (800) 328-2518 (24-hour technical support for physicians and medical professionals)

EuropeMedtronic International Trading SàrlRoute du Molliau 31Case postale 84CH-1131 TolochenazSwitzerlandTel: 41.21.802.7000Fax: 41.21.802.7900

Canada Medtronic of Canada Ltd. 99 Hereford StreetBrampton, Ontario L6Y 0R3CanadaTel: (905) 460-3800Fax: (905) 826-6620Toll-free: 1 (800) 268-5346

Asia Medtronic International, Ltd. Suite 1602 16/F, Manulife Plaza The Lee Gardens, 33 Hysan Avenue Causeway Bay Hong Kong Tel: (852) 2891 4068 Fax: (852) 2591 0313 enquiryap@medtronic.com

Latin AmericaMedtronic USA, Inc.Doral Corporate Center II3750 NW 87th Avenue Suite 700Miami, FL 33178USATel: (305) 500-9328Fax: (786) 709-4244

LifeLineCardioVascular Technical SupportTel: (877) 526-7890Tel: (763) 526-7890Fax: (763) 526-7888E-mail: rs.cstechsupport@medtronic.com

Size Aortic AnnulusDiameter Valve Height

26 mm 20-23 mm 55 mm29 mm 23-27 mm 53 mm31 mm 26-29 mm 52 mm

www.medtronic.com

www.CoreValve.com

INTERNATIONALCAUTION: For distribution only in markets where CoreValve has been approved. Not approved in the USA, Canada or Japan.

CoreValve® Transcatheter Aortic Valve

Refer to Instructions for Use for a complete list of warnings, precautions and contraindications.

INTERNATIONAL

CAUTION: For distribution only in markets where CoreValve has been approved. Not approved in the USA, Canada or Japan.

CoreValve is a registered trademark of Medtronic CV Luxembourg S.a.r.l.

AccuTrak is a trademark of Medtronic, Inc.

UC201106399 EE© Medtronic, Inc. 2011. All Rights Reserved. Printed in Europe.

As of May 2011

CoreValve®

TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) SYSTEM

References

1. Medtronic CoreValve design on file.

Same proven CoreValve® System with true 18 Fr for all valve sizes

*CoreValve treats annulus diameters from 20 to 29 mm.

Treating the broadest range of annulus diameters via transfemoral or subclavian approach 26 mm

For 20-23 mmannulus diameters

29 mm For 23-27 mm

annulus diameters

31 mm For 26-29 mm

annulus diameters

• Basedonsameproven valve design1

- Engineered for optimal hemodynamics

- Designed for durability

• Samefamiliar,easy-to-use18Frdeliverysystem

• SameCoreValveloadingsystem

The only TAVI system to treat patients with annulus diameters up to 29 mm*