Post on 03-Oct-2021
transcript
Micro™ Pendant Downlight - MPD
MICRO PENDANT DOWNLIGHT PERFORMANCE DATA
T 845–565–8500F 845–561–1130
1126 River RoadNew Windsor, NY 12553
© 2018. USAI, LLC. All rights reserved. All designs protected by copyright.
Covered by US Patents: 10,443,822, D857,289 and D864,468. Patents pending. USAI, BeveLED and Classic White are
registered trademarks of USAI, LLCRevised 01/21/2021
usailighting.cominfo@usailighting.com
Page 1
MPD02shown with Recessed
J-box Canopy (PR option)
MPD04shown with Recessed
J-box Canopy (PR option)
MPD06shown with Conduit
Cutout Canopy(PJ option)
MPD08shown with Recessed
J-box Canopy (PR option)
MPD12shown with Recessed
J-box Canopy (PR option)
Micro™ Pendant can be installed with any ceiling type with our stem-mount solution. Suspension options available for every cell size include recessed and
surface mounted junction boxes and conduit, remote and canopy-mounted dimming drivers, and beautifully anodized white, black and silver fi nishes. Just imagine
the possibilities.
FEATURES
• Our smallest LED downlight form factor, now available in pendant mount confi gurations
• Sleek 1.375” profi le integrates beautifully with slatted ceiling systems
• Downlight and Wall Wash distributions available
• Solutions for recessed and surface mount junction boxes and conduit work with any ceiling type
• Choose from remote driver options or canopy mounted integral drivers
Classic White
DELIVERED* MPD02 MPD04 MPD06 MPD08 MPD12PERFORMANCE 2 CELL 4 CELL 6 CELL 8 CELL 12 CELL 8W 13W 21W 27W 41W
Color Rendering Index: 80+ 90+ 80+ 90+ 80+ 90+ 80+ 90+ 80+ 90+
Source Lumens: 750 625 1475 1250 2200 1850 2900 2425 4675 3925
White Bevel Performance:
Lumens Per Watt: 68 57 76 64 72 61 72 61 76 64
Delivered Lumens: 500 425 1000 825 1475 1250 1925 1625 3125 2625
Black Bevel Performance:
Lumens Per Watt: 56 47 62 52 60 50 60 50 63 53
Delivered Lumens: 400 350 825 700 1225 1025 1600 1350 2575 2175
Color Consistency: 2-Step MacAdam Ellipse
*Performance data based on 3000K, 80+ CRI with 50° optic.
CORRELATED COLOR TEMPERATUREMULTIPLIER 2700K 3000K 3500K 4000K
Color Rendering Index: 80+ 90+ 80+ 90+ 80+ 90+ 80+ 90+
Multiplier for Lumen Output: 0.93 0.79 1.00 0.84 1.00 0.84 1.07 0.93
Classic White
T 845–565–8500F 845–561–1130
1126 River RoadNew Windsor, NY 12553
© 2018. USAI, LLC. All rights reserved. All designs protected by copyright.
Covered by US Patents: 10,443,822, D857,289 and D864,468. Patents pending. USAI, BeveLED and Classic White are
registered trademarks of USAI, LLCRevised 01/21/2021
usailighting.cominfo@usailighting.com
Micro™ Pendant Downlight - MPDMPD022 CELL
2-11/16”
3-3/8”
Page 2
1-3/8”
7/16”
5-1/8”
1-3/8”
Recessed J-Box CanopyPR1, PR2, PR3
(remote driver required)
Conduit Cutout CanopyPJ1, PJ2, PJ3
(remote driver required)
3-3/8”
1-3/8”
6-1/8”
1-3/8”
Canopy Mounted DriverPD1, PD2, PD3
2-11/16” 1-3/8”
3-3/8”
3-7/8”
1-3/8”
2-1/2”
6-1/8”
3/8” Ø StemMax 95” LongField Cuttable
3/8” Ø StemMax 95” LongField Cuttable
3/8” Ø StemMax 95” LongField Cuttable
MPD044 CELL
3/8” Ø StemMax 95” LongField Cuttable
3/8” Ø StemMax 95” LongField Cuttable
5-3/16”
3-3/8”
1-3/8”
7/16”
5-1/8”
1-3/8”
5-3/16”
3-3/8”
1-3/8”
6-1/8”
3-7/8”
5-3/16” 1-3/8”
3-3/8”
6-1/8”
1-3/8”
5-1/8”6-1/8”
5-1/8” 6-1/8”
3/8” Ø StemMax 95” LongField Cuttable
2-3/8”
5-3/16”
2-3/8”
1-3/8”
5-3/16”
2-11/16”
2-11/16”
2-11/16”
Stem lengths>48” require coupler (provided)
Stem lengths>48” require coupler (provided)
Stem lengths>48” require coupler (provided)
Stem lengths>48” require coupler (provided)
Stem lengths>48” require coupler (provided)
Stem lengths>48” require coupler (provided)
T 845–565–8500F 845–561–1130
1126 River RoadNew Windsor, NY 12553
© 2018. USAI, LLC. All rights reserved. All designs protected by copyright.
Covered by US Patents: 10,443,822, D857,289 and D864,468. Patents pending. USAI, BeveLED and Classic White are
registered trademarks of USAI, LLCRevised 01/21/2021
usailighting.cominfo@usailighting.com
Micro™ Pendant Downlight - MPDMPD066 CELL
7-11/16”
3-3/8”
Page 3
1-3/8”
7/16”
5-1/8”
1-3/8”
2-3/8”
3-3/8”
7-11/16” 1-3/8”
6-1/8”
1-3/8”
5-3/16”
7-11/16” 1-3/8”
3-3/8”
3-7/8”
1-1/4”
6-1/8”
3/8” Ø StemMax 95” LongField Cuttable
3/8” Ø StemMax 95” LongField Cuttable 3/8” Ø Stem
Max 95” LongField Cuttable
MPD088 CELL
3/8” Ø StemMax 95” LongField Cuttable 3/8” Ø Stem
Max 95” LongField Cuttable
3/8” Ø StemMax 95” LongField Cuttable
10-3/16”
3-3/8”
1-3/8”
7/16”
5-1/8”
1-3/8”
10-3/16”
3-3/8”
1-3/8”
6-1/8”
3-7/8”
10-3/16” 1-3/8”
3-3/8”
6-1/8”
1-3/8”
Recessed J-Box CanopyPR1, PR2, PR3
(remote driver required)
Conduit Cutout CanopyPJ1, PJ2, PJ3
(remote driver required)
Canopy Mounted DriverPD1, PD2, PD3
5-1/8” 6-1/8”
5-1/8” 6-1/8”1-3/8”
5-3/16”
2-3/8”
Stem lengths>48” require
coupler (provided)
Stem lengths>48” require
coupler (provided)
Stem lengths>48” require
coupler (provided)
Stem lengths>48” require
coupler (provided)
Stem lengths>48” require
coupler (provided)
Stem lengths>48” require
coupler (provided)
T 845–565–8500F 845–561–1130
1126 River RoadNew Windsor, NY 12553
© 2018. USAI, LLC. All rights reserved. All designs protected by copyright.
Covered by US Patents: 10,443,822, D857,289 and D864,468. Patents pending. USAI, BeveLED and Classic White are
registered trademarks of USAI, LLCRevised 01/21/2021
usailighting.cominfo@usailighting.com
Micro™ Pendant Downlight - MPDMPD1212 CELL
15-3/16”
3-3/8”
Page 4
1-3/8”
7/16”
5-1/8”
1-3/8”
2-3/8”
3-3/8”
15-3/16”
6-1/8”
1-3/8”
3/8” Ø StemMax 95” LongField Cuttable
3/8” Ø StemMax 95” LongField Cuttable
1-3/8”
15-3/16” 1-3/8”
3-3/8”
3-7/8”
1-3/8”
6-1/8”
3/8” Ø StemMax 95” LongField Cuttable
Recessed J-Box CanopyPR1, PR2, PR3
(remote driver required)
Conduit Cutout CanopyPJ1, PJ2, PJ3
(remote driver required)
Canopy Mounted DriverPD1, PD2, PD3
5-1/8”
6-1/8”
5-3/16”
Stem lengths>48” require coupler (provided)
Stem lengths>48” require coupler (provided)
Stem lengths>48” require coupler (provided)
Body Finish
Bevel Finish
Canopy provided to match bodyfi nish
Canopy provided to match bodyfi nish
Body Finish
Bevel Finish
Canopy provided to match bodyfi nish
Body Finish
Bevel Finish
Body Finish
HOW TO SPECIFY
Micro™ Pendant Downlight with Remote Driver - MPD
T 845–565–8500F 845–561–1130
1126 River RoadNew Windsor, NY 12553
© 2018. USAI, LLC. All rights reserved. All designs protected by copyright.
Covered by US Patents: 10,443,822, D857,289 and D864,468. Patents pending. USAI, BeveLED and Classic White are
registered trademarks of USAI, LLCRevised 01/21/2021
usailighting.cominfo@usailighting.com
MicroPendant
MPDMicroPendantDownlight
Size / WattageOptions
08H18W LED
13H113W LED
21H121W LED
27H127W LED
41H141W LED
MPD__ __ RM
FAMILY LED COLOR CHOICES FIXTURE
Bevel FinishOptionsWH WhiteMatte
BLBlack Matte
BG Black Specular
SMSilver Matte
SG Silver Specular
BZBronze Specular
RGRose Gold Specular
Numberof Cells
022 Cell
044 Cell
066 Cell
088 Cell
1212 Cell
Page 5
3. Specify Remote Power SupplySpecify remote power supply part number in table below
1. Specify fi xture part number and options.
RPA
MountingOptions
Rigid Stem Mount +Conduit Cutout Canopy Style(fi eld cuttable)
PJ1 24” length*
PJ2 48” length*
PJ3 95” length*
Rigid Stem Mount +Recessed JBox Canopy Style(fi eld cuttable)
PR1 24” length*
PR2 48” length*
PR3 95” length*
PXC
Stem
PXC PendantMount Field CuttableStem,3/8ӯ
Size
24 24” Length
4848” Length
9595” Length
Finish
WHWhite
SCConduit Silver
BLBlack
2. Order Pendant Stem
USAI
Power
Supply
Must Be
Specifi ed
PENDANT
BeamOptions
3535° Beam
5050° Beam
RemotePowerSupplyRMRemote Power Supply (Specify in table below)
LED ColorTemperatureOptions
27KS2700K, 80+ CRI
27KH2700K, 90+ CRI
30KS 3000K, 80+ CRI
30KH3000K, 90+ CRI
35KS 3500K, 80+ CRI
35KH3500K, 90+ CRI
40KS 4000K, 80+ CRI
40KH4000K, 90+ CRI
2-Step MacAdamEllipse Color Consistency is standard for all
Body FinishOptionsWH White
BLBlack
SC Conduit Silver
Type Fixture Fixture Size and Voltage Remote Dimming Driver Type Remote EmergencyCode Quantity per Wattage Options and Dim Level Option Remote Power Supply
RPA 08H1 2 Cell 8W LED UNV D4H Lutron H ECO, 1% Fade (1)Micro 13H1 4 Cell 13W LED 120V - D6E EldoLED 0-10V, 1%Remote 01 Fixture 21H1 6 Cell 21W LED 277V D6F EldoLED 0-10V, 1%Power 27H1 8 Cell 27W LED Supply 41H1 12 Cell 41W LED* D3 Lutron 2-wire, 1% 02 Fixtures 08H1 2 Cell 8W LED 120V D19 Phase 2-wire, 1% (1)
08 Fixtures Max 08H1 2 Cell 8W LED UNIV D6E EldoLED 0-10V, 1% 04 Fixtures Max
13H1 4 Cell 13W LED 120V D6F EldoLED 0-10V, 1% 21H1 6 Cell 21W LED 277V D7E EldoLED DALI, 1% 03 Fixtures Max 27H1 8 Cell 27W LED D8E EldoLED DMX, 1% 02 Fixtures Max 41H1 12 Cell 41W LED
* Note: 12 cell requires two drivers for D3, D4H and D19 driver types 1 Not available with 08H1 LED
SINGLE CHANNEL REMOTE POWER SUPPLIES
MULTI CHANNEL REMOTE POWER SUPPLIES
EM7Emergency Batteryprovides emergency power to one fi xture perpower supply andrequires remote enclosure (by others) with a minimum size of14.5” L x 6.5” W x 3” H.Emergency battery is not available with 2 cellMPD02-08H1 LED
PJ option
PR option
Classic White
HOW TO SPECIFY
Micro™ Pendant Downlight with Canopy Mounted Driver - MPD
T 845–565–8500F 845–561–1130
1126 River RoadNew Windsor, NY 12553
© 2018. USAI, LLC. All rights reserved. All designs protected by copyright.
Covered by US Patents: 10,443,822, D857,289 and D864,468. Patents pending. USAI, BeveLED and Classic White are
registered trademarks of USAI, LLCRevised 01/21/2021
usailighting.cominfo@usailighting.com
Page 6
1. Specify fi xture part number and options.
MicroPendant
MPDMicroPendantDownlight
Size / WattageOptions
08H18W LED
13H113W LED
21H121W LED
27H127W LED
41H141W LED
MPD__ __
FAMILY LED COLOR CHOICES FIXTURE
Numberof Cells
022 Cell
044 Cell
066 Cell
088 Cell
1212 Cell
MountingOptions
Rigid Stem Mount +Canopy Mounted Driver Style(fi eld cuttable)
PD1 24” length*
PD2 48” length*
PD3 95” length*
PXC
Stem
PXC PendantMount Field CuttableStem,3/8ӯ
Size
24 24” Length
4848” Length
9595” Length
Finish
WHWhite
SCConduit Silver
BLBlack
2. Order Pendant StemPENDANT
BeamOptions
3535° Beam
5050° Beam
LED ColorTemperatureOptions
27KS2700K, 80+ CRI
27KH2700K, 90+ CRI
30KS 3000K, 80+ CRI
30KH3000K, 90+ CRI
35KS 3500K, 80+ CRI
35KH3500K, 90+ CRI
40KS 4000K, 80+ CRI
40KH4000K, 90+ CRI
2-Step MacAdamEllipse Color Consistency is standard for all
Body FinishOptionsWH White
BLBlack
SC Conduit Silver
VoltageOptions
UNV120V-277V
120V
Dimming Driver Options
For use with UniversalVoltage 120V - 277V
D4H Lutron H ECO, 1%Fade (1, 2)
D6E EldoLED 0-10V, 1%(provided standard)
D6F EldoLED 0-10V, 1%
For use with 120V only
D3 Lutron Hi-Lume 1%2-wire, 120V only (2)
D19 Phase dimming 1%,120V only (1, 2)
1 Not available with 08H1 LED2 12 cell requires two drivers for D3, D4H and D19 driver types
PD option
Classic White
Bevel FinishOptionsWH WhiteMatte
BLBlack Matte
BG Black Specular
SMSilver Matte
SG Silver Specular
BZBronze Specular
RGRose Gold Specular
HOW TO SPECIFY
Micro™ Pendant Downlight - MPD
T 845–565–8500F 845–561–1130
1126 River RoadNew Windsor, NY 12553
© 2018. USAI, LLC. All rights reserved. All designs protected by copyright.
Covered by US Patents: 10,443,822, D857,289 and D864,468. Patents pending. USAI, BeveLED and Classic White are
registered trademarks of USAI, LLCRevised 01/21/2021
usailighting.cominfo@usailighting.com
Page 7
FIELD REPLACEABLE LED LIGHT ENGINEis serviceable through the aperture with a Philips screwdriver. All USAI Lighting Classic White light engines feature industry-leading color consistency within a 2-Step MacAdam Ellipse..
BODY 1-3/8” wide extruded aluminum body available in silver matte, anodized, white or black electrocoated fi nish. Bevel inserts are available in a variety of vacuum- metallized fi nishes.
FIXTURE WEIGHT Weights do not include pendant stem mounting hardware or remote drivers. MPD02 MPD04 MPD06 MPD08 MPD12 1LB 2LBS 2.5LBS 3LBS 3.5LBS
FIELD REPLACEABLE CANOPY MOUNTED DRIVER100%-1% solid state electronic constant current dimming driver with a high power factor is provided standard. All canopy mounted drivers are located within the canopy and are serviceable from below the ceiling. Some on-time delay may be experienced depending on control system used. All dimming drivers comply with IEEE C62.41 surge protection.
REMOTE LOCATION DRIVER All remote dimming driver options must be clearly specifi ed in the “RP” table. Remote power supplies require enclosures by others that meet local codes and must be located in an accessible service panel within 100ft of the light fi xture; see remote driver details for coordination of enclosure sizes. All dimming drivers comply with IEEE C62.41 surge protection.
REMOTE LOCATION EMERGENCY Remote emergency battery IOTA ILB-CP07 provides 200mA to one fi xture for 90 minutes. When used with multichannel power supplies, emergency battery supplies power to 1 fi xture only through channel 1. Remote power supplies with EM option require an enclosure with minimum size of 14.5”L x 6.5”W x 3”H by others that meets local codes. Battery is not available with 08H1 LED. Note: Remote power supply for 12 cell pendants contains two drivers for D2, D3, D4E and D19 driver types.
SPECIFICATIONS
Remote Power Supply Dimming Option Wire Gauge Required* (by others) UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% UNV-D7E EldoLED DALI, 1% UNV-D8E EldoLED DMX, 1%
If you want to connect 8 fi xtures maximum per power supply select from the following options:
RPRP2REMOTEREMOTEPOWEPOWERSUPPLYSUPPLY
-
A
+
INPUT WIREINPUT WIRES
-+
USE FOR WIRING FIXTURESUSE FOR WIRING FIXTURESMDF0MDF02M2M DP02DP02MDF0MDF04M4M DP04DP04MDF0MDF06M6M DP06DP06MDF0MDF08M8M DP08DP08
FIXTURFIXTURE
SEE DIMMING COMPSEE DIMMING COMPATIBILITATIBILITYSHEET FOR SHEET FOR DETAILDETAILS
SEE DIMMING COMPSEE DIMMING COMPATIBILITATIBILITYSHEET FOR SHEET FOR DETAILDETAILS
B
USE ONLY FOR WIRING FIXTURESUSE ONLY FOR WIRING FIXTURESMDF0MDF02MDP0MDP02(2) FIXTURES IN SERIES(2) FIXTURES IN SERIES
INPUT WIREINPUT WIRES
FIXTURE FIXTURE 1
+
RPRP2REMOTEREMOTEPOWEPOWERSUPPLYSUPPLY
-+
- FIXTURE FIXTURE 2
-+
If you want to connect 1or 2 fi xtures per power supply select from the following options:
Remote Power Supply Dimming Option Wire Gauge Required* (by others) UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% 120V-D3 Lutron 2-wire phase, 1% 14/12 6.25” W x 4” L x 2” H
* Wire gauge 14/12 = Maximum distance from light fi xture to remote power supply is 100’ using 12 gauge wire, 50’ using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fi xture to remote power supply is 100’ using 16 gauge wire, 50’ using 18 gauge wire.
SEE DIMMINGCOMPATIBILTY
SHEETS FOR DETAILS
SEE DIMMINGCOMPATIBILTY
SHEETS FOR DETAILS
HOMERUN SERIES
2-Cell Micro Remote Power Supply Requirements and Wiring Diagrams 2-Cell can be wired in homeruns (wiring diagram A) or in series pairs (wiring diagram B).
18/16 10.375” W x 4” L x 2” H
18/16 6.25” W x 4” L x 2” H
Requirements and Wiring Diagrams forMPD02MPW02
RPA-08-08H1
RPA-01-08H1RPA-02-08H1
RPAREMOTEPOWERSUPPLY
RPAREMOTEPOWERSUPPLY
Minimum Enclosure Size Required
Minimum Enclosure Size Required
HOW TO SPECIFY
Micro™ Pendant Downlight - MPD
T 845–565–8500F 845–561–1130
1126 River RoadNew Windsor, NY 12553
© 2018. USAI, LLC. All rights reserved. All designs protected by copyright.
Covered by US Patents: 10,443,822, D857,289 and D864,468. Patents pending. USAI, BeveLED and Classic White are
registered trademarks of USAI, LLCRevised 01/21/2021
usailighting.cominfo@usailighting.com
Page 8
SPECIFICATIONS (continued)
If you want to connect 3-4 fi xtures maximum per power supply select from the following options:
If you want to connect 1 fi xture maximum per power supply select from the following options:
* Wire gauge 14/12 = Maximum distance from light fi xture to remote power supply is 100’ using 12 gauge wire, 50’ using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fi xture to remote power supply is 100’ using 16 gauge wire, 50’ using 18 gauge wire. ** Emergency battery remote power supplies cannot be located any more than 50 feet from light fi xture.
RPRP2REMOTEREMOTEPOWEPOWERSUPPLYSUPPLY
-
A
+
INPUT WIREINPUT WIRES
-+
USE FOR WIRING FIXTURESUSE FOR WIRING FIXTURESMDF0MDF02M2M DP02DP02MDF0MDF04M4M DP04DP04MDF0MDF06M6M DP06DP06MDF0MDF08M8M DP08DP08
FIXTURFIXTURE
SEE DIMMING COMPSEE DIMMING COMPATIBILITATIBILITYSHEET FOR SHEET FOR DETAILDETAILSSEE DIMMING
COMPATIBILTY SHEETS
FOR DETAILS
4, 6, and 8-Cell Micro Remote Power Supply Requirements and Wiring DiagramsMust be wired in homeruns per wiring diagram “A” below.
HOMERUN
Requirements and Wiring Diagrams for MPD04 MPD06 MPD08MPW04 MPW06 MPW08
RPAREMOTEPOWERSUPPLY
Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% UNV-D7E EldoLED DALI, 1% UNV-D8E EldoLED DMX, 1%
18/16 10.375” W x 4” L x 2” H 14.5" W x 6.5" L x 3" H
Minimum Enclosure Size Required (by others)
RPA-04-13H1RPA-04-21H1RPA-03-27H1
Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNV-D4H Lutron H ECO, 1% Fade 14/12 6.25” W x 4” L x 2” H UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% 120V-D3 Lutron 2-wire phase, 1% 14/12 6.25” W x 4” L x 2” H 120V-D19 Hatch 2-wire phase, 1% 14/12 5.75” W X 2.625” L X 2” H
18/16 6.25” W x 4” L x 2” H 14.5" W x.5" L x 3" H
Minimum Enclosure Size Required (by others)
RPA-01-13H1RPA-01-21H1RPA-01-27H1
If you want to connect 2 fi xtures maximum per power supply select from the following options:
If you want to connect 1 fi xture maximum per power supply select from the following options:
* Wire gauge 14/12 = Maximum distance from light fi xture to remote power supply is 100’ using 12 gauge wire, 50’ using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fi xture to remote power supply is 100’ using 16 gauge wire, 50’ using 18 gauge wire. ** Emergency battery remote power supplies cannot be located any more than 50 feet from light fi xture.
-
CSEE SEE DIDIMMING COMMING COMPATMPATIBIBILITILITY
SHSHEEEET T FOFOR R DEDETATAILILS
++++
+
USE ONLY FOR WIRING FIXTURESUSE ONLY FOR WIRING FIXTURESMDF1MDF12MDP12 MDP12 EACH FIXTURE REQUIRES (2) RUNEACH FIXTURE REQUIRES (2) RUNS
-
FIFIXTURXTURE
-
-
RPRP2REMOTEREMOTEPOWEPOWERSUPPLYSUPPLY
+
INPUT WIREINPUT WIRESSEE DIMMINGCOMPATIBILTY
SHEETS FOR DETAILS
12-Cell Micro Remote Power Supply Requirements and Wiring Diagrams*Must be wired with 2 homeruns per fi xtures as shown in wiring diagram “C” below.* Note 12 cell requires two drivers for D3, D4E and D19 driver types.
2X HOMERUN
Requirements and Wiring Diagrams for MPD12MPW12
RPA-02-41H1
RPAREMOTEPOWERSUPPLY
Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% UNV-D7E EldoLED DALI, 1% UNV-D8E EldoLED DMX, 1%
18/16 10.375” W x 4” L x 2” H 14.5" W x 6.5" L x 3" H
Minimum Enclosure Size Required (by others)
Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNV-D4H Lutron H ECO, 1% Fade 14/12 8” W x 6.75” L x 2” H UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% 120V-D3 Lutron 2-wire phase, 1% 14/12 8” W x 6.75” L x 2” H 120V-D19 Hatch 2-wire phase, 1% 14/12 7.25” W x 4” L x 2” H
18/16 8” W x 6.75” L x 2” H 14.5" W x 6.5" L x 3" H
Minimum Enclosure Size Required (by others)
RPA-01-41H1
HOW TO SPECIFY
Micro™ Pendant Downlight - MPD
T 845–565–8500F 845–561–1130
1126 River RoadNew Windsor, NY 12553
© 2018. USAI, LLC. All rights reserved. All designs protected by copyright.
Covered by US Patents: 10,443,822, D857,289 and D864,468. Patents pending. USAI, BeveLED and Classic White are
registered trademarks of USAI, LLCRevised 01/21/2021
usailighting.cominfo@usailighting.com
Page 9
SPECIFICATIONS (continued)
4”OCTAGONAL JUNCTION BOX DETAIL
4"Ø X 1-1/2" Deep Octagon J-Box
(by others)
1-1/2”3-1/2”
3-1/2”
4”
CONDUIT CUTOUT KEYSOLID COVER KEY
3 provided with each
Conduit Cutout Canopy
3 provided with each
Conduit Cutout Canopy
KEY COVER DETAIL
PENDANT STEM MOUNT WITH CANOPY MOUNTED DRIVER 3/8” Ø (1/8” IPS) steel stem is fi eld cuttable and is provided in length specifi ed (24”, 48” or 95”) with 30° hang straight. Installers must cut the stem in the fi eld to desired length. Rigid steel stem is provided in fi nish as specifi ed in pendant stem ordering table. 6-1/8” X 6-1/8” square x 3-7/8” deep canopy is provided in fi nish matching body fi nish specifi ed for mounting to recessed mounted junction box. Please contact factory if a different canopy color is desired. Dimming driver is mounted inside canopy assembly.
WARRANTYBased on IESNA LM80-2008, Micro has a 50,000 hour rated life at 70% lumen maintenance (L70). USAI Lighting Warranty covers replacement parts for 5 years from date of shipment. Warranty is void if Micro is used with any power supply other than that which is provided by USAI.
LISTINGS Dry/Damp location. NRTL/CSA-US tested to UL standards. IBEW union made.
NOTES• Not for use in corrosive environment• Use of pressure washer voids warranty• Ambient temperatures at fi xture location should not exceed 40°C during normal operation.
PHOTOMETRICS Consult factory or website for IES fi les. Tested in accordance with IESNA LM79.
MOUNTINGHardware included for mounting to 4” octagonal junction box.
PENDANT STEM MOUNT WITH REMOTE DRIVER 3/8” Ø (1/8” IPS) steel stem is fi eld cuttable and provided in length specifi ed (24”, 48” or 95”) with 30° hang straight. Installers must cut the stem in the fi eld to desired length. Stem lengths greater than 48” are provided with a coupler to connect two steel stem lengths together (shown in drawings). Rigid steel stem is provided in fi nish as specifi ed in pendant stem ordering table.
RECESSED JBOX CANOPY: I f recessed J-box canopy style is specifi ed (PR1, PR2 or PR3 options) a 5-1/8” x 5-1/8” square x 7/16” deep canopy is provided for mounting to recessed mounted junction box. Recessed jbox canopy is provided in fi nish matching body fi nish specifi ed. If a different canopy color is desired, please contact factory.
CONDUIT CUTOUT CANOPY: If Conduit Cutout Canopy is specifi ed (PJ1, PJ2 or PJ3 options) a 5-3/16” x 5-3/16” square x 2-3/8” deep canopy is provided for mounting to standard 4” octagonal surface mounted junction box. Conduit cutout canopy has 4 keyslots, one in each side, and ships with three conduit cutout keys and three solid cover keys which are fi eld interchangeable and can be confi gured to accommodate any ceiling layout using ½” or ¾” conduit. Conduit cutout canopy is provided in fi nish, matching body fi nish specifi ed. If a different canopy color is desired, please contact factory.
Conduit End Straight Conduit L Conduit T Conduit
CONDUIT CUTOUT MOUNTING EXAMPLE
V+ RED
V- BLACK
DIMMING DRIVER WIRING SCHEMES:
DIMMING DRIVER COMPATIBILITY SELECTION GUIDE
D2 / DIML2
1126 River RoadNew Windsor, NY 12553
www.usailighting.cominfo@usailighting.com
© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-2 Revised 03/22/2017
T 845–565–8500F 845–561–1130USAI
®
Lighting
D2 / DIML2 LED: 0-10V Dimming Driver Wiring (Dims down to 10%)
LED0-10V (-)
0-10V (+)
SWITCHED HOT
NEUTRAL
USAI®
Lighting
D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER
D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V / 277V Crestron iLux dimmer expansion module CLS-EXP-DIMFLV 100% - 10% Crestron DIN Rail dimmer DIN-4DIMFLV4 100% - 10% Crestron DIN Rail analog output module DIN-A08 100% - 10% Crestron 8 Channel dimmer module GLX-DIMFLV8 100% - 10% Crestron 8 Channel dimmer module GLXP-DIMFLV8 100% - 10% Leviton IllumaTech dimmer IP710-DLX 100% - 10% Lightolier (Philips) Vega V2000FAMU 100% - 10% Lutron Diva DVTV-XX 100% - 10%
Use source current per fi xture specifi cation sheet to determine number of fi xtures per dimmer. Max number of fi xtures is limited by dimmer load rating.
* NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details.
DIMMER: 0-10V (BY OTHERS)
GRAY
PURPLE
BLACK
WHITE
GREEN
GND
V+ RED
V- BLACK
FIXTURE
DRIVER
LINE
NEUTRAL
CLASS 2 CONTROL WIRES
RELAY (BY OTHERS)
LED0-10V (-)
0-10V (+)
SWITCHED HOT
NEUTRAL
D2 / DIML2 0-10V DIMMING (NO RELAY)
DIMMER: 0-10V w/POWER SWITCHING
(BY OTHERS)
GRAY
PURPLE
BLACK
WHITE
GREEN
GND
FIXTURE
DRIVER
NEUTRAL
LINE
GROUND
NOTE:If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wirestogether.
NOTE:If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wirestogether.
NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fi xture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specifi c dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS
1. Keep these instructions in a safe place for future reference. 2. Only qualifi ed electricians in accordance to local codes should install these fi xtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).
DIMMING DRIVER WIRING SCHEMES:
DIMMING DRIVER COMPATIBILITY SELECTION GUIDE
D3 / DIML3
1126 River RoadNew Windsor, NY 12553
www.usailighting.cominfo@usailighting.com
© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-3 Revised 03/22/2017
T 845–565–8500F 845–561–1130USAI
®
Lighting
D3 / DIML3 LED: Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / LED Dimming Driver Wiring (Dims down to 1%) 120V
USAI®
Lighting
D3 / DIML3 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Dimmer* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet ELV10 100% - 1% 1 – 26 1 – 13 ETC Unison DRd Cabinet ELV10 100% - 1% 1 – 26 1 – 13 Lutron Maestro Wireless® 600W dimmer MRF2-6ND-120- 100% - 1% 1 – 8 1 – 4 Lutron Maestro Wireless® 1000W dimmer MRF2-10ND-120- 100% - 1% 1 – 13 1 – 6 Lutron HomeWorks® QS adaptive dimmer HQRD-6NA- 100% - 1% 1 – 8 1 – 4 Lutron HomeWorks® QS 600W dimmer HQRD-6ND- 100% - 1% 1 – 8 1 – 4 Lutron HomeWorks® QS 1000 W dimmer HQRD-10ND- 100% - 1% 1 – 13 1 – 6 Lutron Caseta Wireless® Pro 1000W dimmer PD-10NXD- 100% - 1% 1 – 13 1 – 6 Lutron Stanza® dimmer SZ-6ND- 100% - 1% 1 – 8 1 – 4 Lutron RadioRA® 2 adaptive dimmer RRD-6NA- 100% - 1% 1 – 8 1 – 4 Lutron RadioRA® 2 1000 W dimmer RRD-10ND- 100% - 1% 1 – 6 1 – 3 Lutron myRoom DIN power module MQSE-4A1-D 100% - 1% 1 – 6 1 – 3 Lutron HomeWorks® QS wallbox power module HQRJ-WPM-6D-120- 100% - 1% 1 – 26 1 – 13 Lutron Homeworks® DIN power module LQSE-4A1-D 100% - 1% 1 – 6 1 – 3 Lutron HomeWorks® wallbox power module HWI-WPM-6D-120 100% - 1% 1 – 26 1 – 13 Lutron GRAFIK Eye® QS control unit QSGR-, QSGRJ- 100% - 1% 1 – 26 1 – 13 Lutron GRAFIK Eye® 3000 control unit GRX-3100-, GRX-3500- 100% - 1% 1 – 26 1 – 13 Lutron RPM-4U module HW-RPM-4U-120, LP-RPM-4U-120 100% - 1% 1 – 26 1 – 13 Lutron RPM-4A module HW-RPM-4A-120, LP-RPM-4A-120 100% - 1% 1 – 26 1 – 13 Lutron GP dimming panels Various 100% - 1% 1 – 26 1 – 13 Lutron Ariadni CL 250W dimmer AYCL-253P- 100%-1% 1 – 8 1 – 4 Lutron Diva CL 250W dimmer DVCL-253P-, DVSCCL-253P- 100%-1% 1 – 8 1 – 4 Lutron Grafi k T CL or RF CL dimmer GT-250M-, GTJ-250M- 100%-1% 1 – 8 1 – 4 Lutron Nova T CL 250W dimmer NTCL-250- 100%-1% 1 – 10 1 – 5
* NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details.
LED
SWITCHED HOT
NEUTRAL
D3 / DIML3 2 WIRE PHASE DIMMING
DIMMER: 2 WIRE PHASE(BY OTHERS)
BLACK
WHITE
GREEN
GND
V+ RED
V- BLACK
FIXTURE
DRIVER
NEUTRAL
LINE
GROUND
ONLY FOR SWITCHES WITH NEUTRAL
NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fi xture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specifi c dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS1. Keep these instructions in a safe place for future reference. 2. Only qualifi ed electricians in accordance to local codes should install these fi xtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).
© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-6 Revised 08/16/2019
DIMMING DRIVER COMPATIBILITY SELECTION GUIDE
D6A / DIML6A and D6E / DIML6ED6B / DIML6B and D6F / DIML6F
DIMMING DRIVER WIRING SCHEMES:
USAI®
LightingIMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).
LED0-10V (-)
0-10V (+)
SWITCHED HOT
NEUTRAL
D6 / DIML60-10V DIMMING W/RELAY TO SWITCH POWER
DIMMER: 0-10V
GRAY
PURPLE
BLACK
WHITE
GREEN
GND
FIXTURE
DRIVER
LINE
NEUTRAL
CLASS 2 CONTROL WIRES
RELAY (BY OTHERS)
DIML6A, 6B 0-10V DIMMING (NO RELAY)
DIMMER: 0-10V w/POWER SWITCHING
(BY OTHERS)
FIXTURE
V+ RED
V- BLACK
USAI®
Lighting
1126 River RoadNew Windsor, NY 12553
V+ RED
V- BLACK
LED0-10V (-)
0-10V (+)
SWITCHED HOT
NEUTRAL
D6 / DIML60-10V DIMMING (NO RELAY)
DIMMER: 0-10V w/POWER SWITCHING
(BY OTHERS)
GRAY
PURPLE
BLACK
WHITE
GREEN
GND
FIXTURE
DRIVERLINE
GROUND
D6A / DIML6A and D6E / DIML6E LED Dimming Compatibility TableD6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with the dimming controls listed in the table below.D6A / DIML6A = EldoLED SOLOdrive 0-10V control dims from 100% to 0.1%D6E / DIML6E = EldoLED ECOdrive 0-10V control dims from 100% to 1%
T 845–565–8500F 845–561–1130
NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.
Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6A 6E Lutron Diva DVTV/NFTV with PP-20 99% - 0.1% 1% Lutron Nova T NTFTV with PP-20 99% - 0.1% 1% Lutron Energi Savr Node QSN-4T16-S 100% - 0.1% 1% Lutron GP Dimming Panels TVM2 Module 99% - 0.1% 1% Lutron Interfaces GRX-TVI w/ GRX3503 100% - 0.1% 1% Sensor Switch nIO nIO EZ 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1%
Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer.Enlighted compatible.
D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart
D6B / DIML6B and D6F / DIML6F LED Dimming Compatibility TableD6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with the dimming controls listed in the table below.D6B / DIML6B = EldoLED SOLOdrive 0-10V control dims from 100% to 0.1% D6F / DIML6F = EldoLED ECOdrive 0-10V control dims from 100% to 1%
D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6B 6F Bush-Jaeger Electronic potentiometer 2112U-101 100% - 0.1% 1% Jung Electronic potentiometer 240-10 100% - 0.1% 1% Leviton Iluma Tech dimmer IP710-DLX 100% - 0.1% 1% Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 100% - 0.1% 1% Merten Electronic potentiometer 5729 100% - 0.1% 1% Pass & Seymour Titan CD4FB-W 100% - 0.1% 1% Watt Stopper Miro DCLV1 100% - 0.1% 1% Synergy Wallbox Dimmers ISD BC 100% - 0.1% 1% ABB i-bus SD/S 2.16.1 100% - 0.1% 1% Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 100% - 0.1% 1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8- 100% - 0.1% 1% Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 100% - 0.1% 1% Crestron DIN Rail Analog Output Module DIN-A08 100% - 0.1% 1% Crestron DIN Rail 0-10V Fluorescent Dimmer DIN-4DIMFLV4 100% - 0.1% 1% Crestron iLux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1%
Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer.Enlighted compatible.
www.usailighting.cominfo@usailighting.com
1126 River RoadNew Windsor, NY 12553
www.usailighting.cominfo@usailighting.com
© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-7 Revised 08/14/2017
T 845–565–8500F 845–561–1130USAI
®
Lighting
DIMMING DRIVER COMPATIBILITY SELECTION GUIDE
D7 / DIML7 and D7EDIMMING DRIVER WIRING SCHEMES:
USAI®
Lighting
D7 / DIML7 and D7E Dimming Driver WiringD7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = EldoLED SOLOdrive DALI control dims from 100% to 0.1%D7E = EldoLED ECOdrive DALI control dims from 100% to 1%
LED
D7 / DIML7 / D7EDALI CONTROLS
V+ RED
V- BLACK
FIXTURE
DRIVER
DALI BUS
WALL CONTROL(BY OTHERS)
LINENEUTRAL
DA
DA
ORANGE (-)ORANGE/WHITE (+)
BLACK WHITE GREEN
GND
NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fi xture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specifi c dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS1. Keep these instructions in a safe place for future reference. 2. Only qualifi ed electricians in accordance to local codes should install these fi xtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).
1126 River RoadNew Windsor, NY 12553
www.usailighting.cominfo@usailighting.com
© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-8 Revised 08/14/2017
T 845–565–8500F 845–561–1130USAI
®
Lighting
DIMMING DRIVER COMPATIBILITY SELECTION GUIDE
D8 / DIML8 and D8EDIMMING DRIVER WIRING SCHEMES:
USAI®
Lighting
LED
V+ RED
V- BLACK
FIXTURE
DRIVER
REDBLACKBAREBLACKWHITEGREEN
GND
LINE
NEUTRAL
SHIELD
DMX (-)
DMX (+)
DMX BUS - XLR CABLE OR SHIELDED DATA CABLE
5 PIN XLR JACKS STANDARD
8 BIT DMX 512 CONTROLLER
(BY OTHERS)
The data cable used must meet the following requirements: • type: shielded, 2-conductor twisted pair • maximum capacitance between conductors: 30 pF/ft • maximum capacitance between conductor and shield: 55 pF/ft • maximum resistance: 0.02 ohms/ft • normal impedance: 100-140 ohms • conductive core: 24 AWG is recommendedIf 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifi cations for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fi xture in line on a circuit to avoid signal loss.
DMX BUS - XLR CABLE OR SHIELDED DATA CABLE
NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fi xture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specifi c dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS1. Keep these instructions in a safe place for future reference. 2. Only qualifi ed electricians in accordance to local codes should install these fi xtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).
D8 / DIML8 and D8E Dimming Driver WiringD8 / DIML8 and D8E are linearly programmed dimming drivers. D8 / DIML8 = EldoLED POWERdrive DMX control dims from 100% to 0.1%D8E = EldoLED POWERdrive DMX control dims from 100% to 1%
D8 / DIML8 / D8EDMX CONTROLS
D19 / DIML19 LED: Hatch XTC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specifi cation and load. 120V only.
1126 River RoadNew Windsor, NY 12553
www.usailighting.cominfo@usailighting.com
© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-19 Revised 03/26/2021
T 845–565–8500F 845–561–1130USAI
®
Lighting
DIMMING DRIVER COMPATIBILITY SELECTION GUIDE
D19 / DIML19DIMMING DRIVER WIRING SCHEMES:
USAI®
Lighting
LED
SWITCHED HOT
NEUTRAL
D19 / DIML192 WIRE PHASE DIMMING
DIMMER: 2 WIRE PHASE(BY OTHERS)
BLACK
WHITE
GREEN
GND
V+ RED
V- BLACK
FIXTURE
DRIVER
NEUTRAL
LINE
GROUND
ONLY FOR SWITCHES WITH NEUTRAL
NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).
D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton IPL06-10Z Use fixture wattage per 6613-xxx fixture specification Lutron S-600P sheet to determine S-603P number of fixtures DVSC-603P per dimmer. Max number CT-600P of fixtures is limited by CT-603P dimmer load rating.
120V ONLY Reverse Phase / ELV Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton 6615 Use fixture wattage per IPE04-xxx fixture specification Lutron NTELV-300 sheet to determine NTELV-600 number of fixtures SELV-300P per dimmer. Max number SELV-303P of fixtures is limited by DVELV-300P dimmer load rating. DVELV-303P