Post on 27-Feb-2022
transcript
MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010
L total = L channel + ⅝" for two endcaps, for fixtures that aren’t a full circleL total = L channel, for fixtures that are a full circle and don’t have endcaps
Fixture Length
5' Example
10' Example
surface suspended suspendeddirect direct / indirect
20' Example
90°
90°
45°
45°
45°
R 118 ⅛" 45˚
R 118 ⅛" 90˚
R 59" 45˚
R 59" 90˚
R 29 ½" 45˚
R 29 ½" 90˚
2 ⅜"
3 ⅛
"
2 ⅜"
3 ⅛
"
2 ⅜"
WARNING: For your safety read and understand these instructions completely before starting in-stallation. Disconnect power supply before instal-ling, servicing or checking. Retain these instruc-tions for ordinary and special maintenance and servicing purposes.
Do not touch the LEDs! Wear ESD protective clothing.
IMPORTANT: This fixture must be installed by a qualified electrician in accordance with the Natio-nal Electric Code and all local codes and prac-tices. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. These codes should be carefully studied before starting work.Mounting hardware supplied by others.
We reserve the right to change our products at any time. Current information is available at xalusa.com.
NOMINAL RADIUS DIAMETER CIRCUMFER.
Ø 5' 29 ½" Ø 59" 15' 5"Ø 10' 59" Ø 118 ⅛" 30' 10"Ø 20' 118 ⅛" Ø 236 ¼" 61' 10"
DIMENSIONS
R 29 1/2" R 59" R 118 1/8"0 - 45° 89 ⅜"0 - 90° 81 11/16" 165 3/16"0 - 135° 52 3/16" 106 11/16" 215 13/16"0 - 180° 56 ½" 115 ½" 233 ⅝"
cutout W 2 ⅝"
R
2 ⅜"
3 1/16"
XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 1 / 7MI-V04 10/16/19
MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010
cutout W 2 ⅝"
cutout W 2 ⅝"
1 2 3Surface mounted option / Place the fixture in the desired position on the ceiling
Mark or score the position
XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 2 / 7MI-V04 10/16/19
MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010
4
7
5
8 9
6
10 11 12
Surface / suspended option Screw on endcap
Option 1 / MINO 2.5 CURVE channel to MINO 2.5 CURVE channel13 14.1
Connect inset to channel
Click in grounding
Connect power to inset
Put on cover
Flex conduit supplied by others
Testing the current:Max. 0.5 ohm resistance!
15.1 17.116.1Insert the pegs into the channel Install the channel connector piece Screw connector piece to channel
1/8"
XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 3 / 7MI-V04 10/16/19
MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010
Suspended version / Thread suspension cables through bracket
22.2 23.2 24.2 Apply adhesive to the inside of the channel seam
20.2 21.2Option 2 / MINO 2.5 CURVE channel to MINO 2.5 channel
18.1 19.1
Screw connector piece to channel
Screw channels together
Screw channels together
28 29 30Insert bracket into junction box
Junction box supplied by others
Thread the suspension cable through the cover plate
Screw bracket to junction box
1/8"
25.2 26.2 27
XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 4 / 7MI-V04 10/16/19
MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010
41 42 43
78"10 ×
158"20 ×
Connect the power to the inset
31
34
36
32
35
33
37
38 39 40
Thread the lamp cable up through the cover plate
Thread lamp cable through bracket
Lamp cable
Bracket
Screw on strain relief The cover plate clicks onto the bracket via springs
Maximum load per rope: 22lbs
max. 78"
Click in grounding
Junction box(supplied by others)
Strain relief
Power feed
Bracket
Cover plate
Lamp cable
Cable suspension
Make sure all components are grounded!
Springs
Bracket
Cover plate
Suspension cable
Lamp cable
Cover plate
XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 5 / 7MI-V04 10/16/19
MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010
44 45 46Connect inset to channel Testing the current:Max. 0.5 ohm resistance!
no dimmingno emergency circuit
dim 0-10 V (5%)no emergency circuit
Hi-lume 3D (1%)3-wire hot dimno emergency circuit
Hi-lume 3D (1%)digital dimno emergency circuit
SUSPENSION CABLE
SUSPENSION CABLE
SUSPENSION CABLE
DIM+ (red)DIM- (orange)
dim line DH (orange)
E1 (red)E2 (orange)
FEEDneutral (white)ground (green)phase (black)
FEEDneutral (white)ground (green)phase (black)dim + (violet)dim - (gray)
FEEDneutral (white)ground (green)phase (black)dim line DH (orange)
FEEDneutral (white)ground (green)phase (black)E1 (violet)E2 (gray)
Inset wiring without emergency circuit
XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 6 / 7MI-V04 10/16/19
MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010
EN
-
Keep these installation instructions in a safe place as reference for any future maintenance works.1. The lamp is not suitable for outdoor use.2. The lamp may only be used with a safety guard.3. Damaged protection glasses and covers have to be replaced immediately.4. 5. No liability is accepted for any subsequent change of the luminaire.6. LEDs are high-quality electronic components! Please avoid touching by hand the LED light emitting surface while assemblying or replacing parts and during maintenance work. 7.8.9.
The LED circuit must always be closed, before the converter is connected to the main power. XAL does not assume any liability for damages resulting from nonobservance of this rule.
FR avant de changer les lampes (si applicable) ou avant de realiser travaux (p.ex nettoyage) a la luminaire. Attendre jusqu‘à ce que la luminaire et les lampes ont frâichit completement. Merci de bien vouloir vous référer aux notes d‘installation
utiliser encore un produit de nettoyage sans alcol qui ne fraye pas le material. Garder cette notice de montage pour possibles travaux de maintenance.La luminaire n‘ est pas apte pour l‘utilizage extrerieur.Utilizer la luminaire seulement avec un dispositif de sécuritéChanger immédiatement des verres de sécurité defectes ou bien des écrans de protection.
Evitez tout contact de la lampe avec de produits chimiques corrosifs. Des LEDs sont des composants électroniques de haute qualité! Eviter tout contact direct de la surface de sorti de lumière de la LED avec les mains lors du montage ou des les travaux de maintenance de la lampe.
Il faut que le circuit de LED soit fermé avant de connecter le convertisseur. XAL ne assume pas la garantie si cette norme ne se respecte pas.
ES La instalación, la puesta en marcha y el mantenimiento sólo deben realizarse por personal especializado considerando esta guía de instalación y todas las normas y reglamentaciones vigentes. Asegurarse de la aptitud eléctrica, mecá-
en esta (p.ej. Limpieza). Esperar hasta que se enfríen la luminaria y la lámpara completamente. Tener en cuenta las instrucciones de montaje del fabricante al colocar, cambiar y utilizar lámparas convencionales. Para la limpieza de la luminaria
La luminaria no es apta para utilizarla en el exterior.La luminaria sólo debe accionar con un dispositivo de seguridad. Cambie de inmediato los vidrios y las tapas de protección dañados.
El circuito LED debe ser cerrado antes de conectar el convertidor. XAL no asume garantía si esta norma no se respete.
We reserve the right to change our products at any time. Current information is available at www.xalusa.com.Nos reservamos en todo momento el derecho de realizar cambios en nuestros productos. n nuestra página web www.xalusa.com siempre se encontrarán datos actuales.
Rev.:001/2014-12-31
Die Leuchte darf nur mit ihrer vollständigen Schutzabdeckung betrieben werden!The lamp is only to be operated with its full protective covering!L‘apparecchio necessita del relativo vetro di protezione!Sólo usar la luminaria con su cobertura de seguridad completa!
Don‘t touch the LED
Recommended room temperature: 77 °F.Temperatura ambiente recomendada: 25 °C.Température ambiante recommandée: 25 °C.
Use gloves.Use guantes.Utiliser des gants.
1.2.3.4.5.6.7.8.9.
1.2.3.4.5.6.7.8.9.
XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 7 / 7MI-V04 10/16/19