Post on 16-May-2018
transcript
Temperature 1
placed next to technology
ProtoCols
WEB / http
XML
SNMP
Alarming / notifications
Email for administrator
SNMP / SNMP trap
for NMS monitoring system
Ethernet LAN
(R1) One Point: TH -> GSM, SNMP, Email
Poseidon 3262 Tset
600 257
INPUTS:
- 1 Temperature
OUTPUTS:
- Ethernet: Email, SNMP NMS
Poseidon 3262
3m
°C
°C %RH
Temperature 1 / Humidity 1
next to Air input
ProtoCols
WEB / http
XML
SNMP
SMS
GSM modem
RS-232
Alarming / notifications
Email for administrator
SNMP / SNMP trap
for NMS monitoring system
SMS for Admin as independent
backup solution.
Poseidon 3265
Ethernet LAN
(R2) One Point: TH -> GSM, SNMP, Email
SMS
HTemp-Rack19
600 330
Poseidon 3265 GSM Tset
600 283
INPUTS:
- 2 Temperatures
- 1 Humidity
OUTPUTS:
- Ethernet: Email, SNMP NMS
- GSM: SMS
3m°C
Temperature 2
placed next to technology
Ethernet LAN
Det. CONTROL
Power
Power failure detector
Door 1
Entrance door detector
Door 2
Sides and backdoor detector
WEB / http
XML
SNMP
Alarming / notifications
Email for administrator
SNMP / SNMP trap
for NMS monitoring system
°C
Temperature 1 / Humidity 1
Cold air ingress to cabinet
Temperature 2
Hot air exit from cabinet
Temperature 3
Monitored device (heat sink)
°C %RH
°C3m
Protocols
Poseidon 3266
(R3) One Rack: THD -> SNMP, Email
SNMP trap for the video
survaillance system (PTZ)
HTemp-Rack19
600 330
Temp-Rack19
600 3293m
4m
PowerEgg
600 237
4 Door Contacts
600 119
Poseidon 3266 Tset
600 253
INPUTS:
- 3 Temperatures
- 1 Humidity
- 4 Door contacts
- 1 Power detection
OUTPUTS:
- Ethernet: Email, SNMP NMS
Ethernet LAN
Det. CONTROL
Power
Power failure detector
Door 1
Entrance door detector
Door 2
Sides and backdoor detector
Alarming / notifications
Email for administrator
SNMP / SNMP trap
for NMS monitoring system
°C
Temperature 1 / Humidity 1
Cold air ingress to cabinet
Temperature 2
Hot air exit from cabinet
Temperature 3
Monitored device (heat sink)
°C %RH
°C3m
(R4) One Rack: THD -> SNMP, Email, SMS
HTemp-Rack19
600 330
Temp-Rack19
600 3293m
4m
PowerEgg
600 237
4 Door Contacts
600 119
Poseidon 1250 Tset
600 042
INPUTS:
- 3 Temperatures
- 1 Humidity
- 4 Door contacts
- 1 Power detection
OUTPUTS:
- Ethernet: Email, SNMP NMS
- GSM: SMS
Protocols
WEB / http
XML
SNMP
SMS
Poseidon 1250
GSM modem
RS-232
SMS
SMS for Admin as independent
backup solution.
GSM Modemcom G10
600 312
Ethernet LAN
WEB / http
XML
SNMP
Alarming / notifications
Email for administrator
SNMP / SNMP trap
for NMS monitoring system
HTemp-Rack19
600 330
Temp-1Wire 3m
600 005 (in SET)
Temp-Rack19
600 329
Protocols
(R5) Four Racks: TH -> SNMP, Email
Four free-standing racks
°C %RH
°C
RJ12
°C
°C
°C
RJ12
RJ12
Poseidon 3262
RJ12
Temp-Rack19
600 329
RJ12
Temperature 1
Monitored device (heat sink)
Temperature 2
Monitored device (heat sink)
Temperature 3
Monitored device (heat sink)
Temperature 5
Monitored device (heat sink)
Temperature 4 / Humidity 1
Cold air ingress to cabinet
Temp-Rack19
600 329
Poseidon 3262 Tset
600 257
INPUTS:
- 5 Temperatures
- 1 Humidity
Placed in 4 19" Racks
OUTPUTS:
- Ethernet: Email, SNMP NMS
Ethernet LAN
HTemp-Rack19
600 330
Temp-1Wire 3m
600 005 (in SET)
Temp-Rack19
600 329
(R6) Four Racks: TH -> SNMP, Email, SMS
Four free-standing racks
°C %RH
°C
RJ12
°C
°C
RJ12
RJ12
Temperature 1
Monitored device (heat sink)
Temperature 2
Monitored device (heat sink)
Temperature 4
Monitored device (heat sink)
Temperature 3 / Humidity 1
Cold air ingress to cabinet
Temp-Rack19
600 329
Poseidon 3265 GSM2 Tset
600 313
INPUTS:
- 4 Temperatures
- 1 Humidity
Placed in 4 19" Racks
OUTPUTS:
- Ethernet: Email, SNMP NMS
- GSM: SMS
GSM modemRS-232
SMS
Poseidon 3265
RJ12
3m
°C
3m
°C
12
34
Sp
ide
r
10m
°C10m
°C10m °C
10m
°CDet Control
Det Control
3m
%RH
12
34
Sp
ide
r
10m
°C10m °C
10m
°C
10m
°C
12
34
Sp
ide
r
10m
°C10m °C
10m
°C
10m
°C
Door 1monitoring of the cabinet with
the Poseidon unit
Temperature 2
General room temperature
Humidity 1
General room humidity
General power input
UPS power input
UPS output
UPS backup power output
Temperature 1monitoring of the cabinet with
the Poseidon unit
12
34
Sp
ide
r
10m
°C10m °C
10m
°C
12
34
Sp
ide
r
10m
°C10m °C
10m
°C
10m
°C1
23
4
Sp
ide
r
10m
°C10m °C
10m
°C
10m
°C
Ceiling to raised
floor connection
10m
°C
Ceiling panel
Raised floor
Temperature 3
Temperature 4
Temperature 5
Temperature 6
Temperature 7
Temperature 8
Temperature 9
Temperature 10
Temperature 11
Temperature 12
Temperature 13
Temperature 14
Temperature 27
Temperature 25
Temperature 24
Temperature 23
Temperature 22
Temperature 21
Temperature 20
Temperature 19
Temperature 18
Temperature 17
Temperature 16
Temperature 15
(R7) ServerRoom: TH -> SNMP, Email
INPUTS:
- 2 Temperatures in the rack
- 1 Humidity in the rack
- 3 Contacts in the rack
- 24 Temperatures in room
OUTPUTS:
- Ethernet: Email, SNMP NMS
(R8) Four Racks + Customized extension: THD -> SNMP, Email, (SMS)
Ethernet LAN
Full monitored Rack:
3 Temperature
1 Humidity
1 Door
Four free-standing racks
°C %RH
°C
°C RJ12
Spider
600 273
Poseidon 3265 GSM2 Tset
600 313 (optionaly)
INPUTS:
- 8 Temperatures
- 2 Humidity
- 5 Door contacts
Placed in 4 19" Racks + extension
OUTPUTS:
- Ethernet: Email, SNMP NMS
- GSM: SMS
GSM modem
RS-232
SMS
Poseidon 1250
Door 2
Sides and backdoor detector
12
34
Sp
ide
r
12
34
Sp
ide
r
3m
°C
3m
°C
3m
°C
3m
°C
°C %RH
RJ12
to sensors in next cabinet..
Full monitored Rack:
3 Temperature
1 Humidity
1+3 Doors
Monitored Rack:
1 Temperature
1 Doors
Monitored Rack:
1 Temperature
1 Doors
Ethernet LAN
Alarming / notifications
Email for administrator
SNMP / SNMP trap
for NMS monitoring system
Temp-1Wire 3m
600 005 (in SET)
Temp-Rack19
600 329
(R9) Six Racks low-cost monitoring: T -> SNMP, Email
Six free-standing racks
Poseidon 3262
RJ12
Temp-Rack19
600 329
Temperature 5
Monitored device (heat sink)
Temp-Rack19
600 329
Poseidon 3262 Tset
600 257
INPUTS:
- 5 Temperatures
- 1 Humidity
Placed in 4 19" Racks
OUTPUTS:
- Ethernet: Email, SNMP NMS
Temperature 1
Hot air exit from cabinet
Temperature 2
Hot air exit from cabinet
Temperature 3
Hot air exit from cabinet
Temperature 4
Hot air exit from cabinet
Temperature 6
Monitored device (heat sink)
°C
°C
°C
°C
°C
RJ12
3m
RJ12
3m
RJ12
3m
RJ12
3m
°C
3m
Temp-Rack19
600 329
Temp-Rack19
600 329