Post on 16-Feb-2019
transcript
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
MORTISE LOCKINSTALLATION INSTRUCTIONS
MUSEO DESIGNER TRIMFM 601 (617418015)
Rev. C (04/13)
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
TABLE OF CONTENTS:DOOR PREPARATION
LOCK HANDING
FULL WORKING TRIM
HALF WORKING TRIM
FULL DUMMY TRIM
HALF DUMMY TRIM
SECONDARY TRIM ATTACHMENTEMERGENCY KEY PLATE
1
2
3
8
12
16
SECTIONALR & L ESCUTCHEON
SECTIONALR & L ESCUTCHEON
SECTIONALR & L ESCUTCHEON
SECTIONALR & L ESCUTCHEON
6
10
13
1415
LOCK HANDING IS CRITICAL TO ENSURE LOCK FUNCTIONS PROPERLY
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.1
DOOR PREPARATION:
FULL WORKING TRIM:LOCK-BODY PREPSECTIONALR & L ESCUTCHEON
HALF WORKING TRIM:LOCK-BODY PREPSECTIONALR & L ESCUTCHEON
FULL DUMMY TRIM:SECTIONALR & L ESCUTCHEON
HALF DUMMY TRIM:SECTIONALR & L ESCUTCHEON
T31046NO ADDITIONAL PREP REQUIRED BEYOND T31046
T31047
T31162
T31164
T31163T30651
T31163T30652
ALL WORKING TRIM MUST FIRST BE PREPARED FOR THE LOCK-BODY THEN FOR THE TRIM
TEMPLATE
NO ADDITIONAL PREP REQUIRED BEYOND T31162
ALL TEMPLATES CAN BE FOUND ATWWW.CORBINRUSSWIN.COM
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.2
Mortise Lock Handing Instructions
RED Locking Screw
Step 1) Move the Red locking screw to side of lock-body being locked (Fig. 1)
Step 2) Push in latch then depress catch plate with screw driver (Fig. 1)
Catch Plate
Step 3) Pull latch out of lock-body and turn latch over (Fig. 2)
Figure 1
Figure 2
Figure 3
Step 4) Push in latch while holding screw driver behind latch tail (Fig. 3)
Note: Push in latch until catch plate is no longer depressed (Fig. 4)
Figure 5
Step 5) Rotate lock front to match bevel of door as shown (Fig. 5)
MAKE SURE CATCH PLATE IS EVEN W/ TOP SURFACE
GOOD BADFigure 4
WARNING: LOCK-IN CAN
OCCUR IF LATCH IS NOT PROPERLY
INSTALLED
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.3
FULL WORKING TRIM INSTALLATION
Step 1) Install strike with shorter (3/4”) mounting screws
Step 2) Insert mortise lock into door and hand tighten longer (1”) mounting screws
SECTIONAL:
Step 3) Thread adapter plate hub into lever and fully tighten
Step 4) Align adapter plate hub with square hole in lever; keeping hub as tight as possible
MAKE SURE LOCK IS UNLOCKED
Step 5) Install O/S trim assembly
NOTE: Spindle can be used to help thread hub into lever
Adapter Plate Hub
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.4
4
6
Spindles
Keypad ribbon cable
Outsideof Door
Installation of Outside Escutcheon
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain the lever spindle is properly engaged in lock. (see diagram and Note A. below) Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.) the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody screws. Remove Allen wrench.
Installation Instructions
Groundwire
Gasket (optional)
C A U T I O NDOOR MUST REMAIN OPEN
DURING INSTALLATION.USE DOOR STOP.
NOTE: Key and cylinder must be rotated as shown
Correct Incorrect
Use Correct Spindle Orientation
STANDARD MUSÉO
GASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces.
NOTE A.For MUSÉO Lever collections ONLY.Rotate adapter bushing as neededto insure horizontal lever position and maximum thread engaging lever - adapter bushing.
LeverLever
GOODBAD
Step 6) Install I/S adapter plate
Set screw hole in hub faces away from lock edge
Align studs on rose with bushings in adapter plate
Step 7) Install I/S spindle and rose
Step 8) Install I/S lever with set screw
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.5
4
6
Spindles
Keypad ribbon cable
Outsideof Door
Installation of Outside Escutcheon
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain the lever spindle is properly engaged in lock. (see diagram and Note A. below) Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.) the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody screws. Remove Allen wrench.
Installation Instructions
Groundwire
Gasket (optional)
C A U T I O NDOOR MUST REMAIN OPEN
DURING INSTALLATION.USE DOOR STOP.
NOTE: Key and cylinder must be rotated as shown
Correct Incorrect
Use Correct Spindle Orientation
STANDARD MUSÉO
GASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces.
NOTE A.For MUSÉO Lever collections ONLY.Rotate adapter bushing as neededto insure horizontal lever position and maximum thread engaging lever - adapter bushing.
LeverLever
Step 10) Mark turn-piece mounting holes and drill two .110” (BIT #35) holes where marked
Step 11) Mount turn-piece
Step 9) Install cylinder and secure with set screw
Slightly retract key to help thread cylinder into lock-body
AFTER INSTALLING CYLINDER FULLY TIGHTEN LOCK MOUNTING SCREWS
CYLINDER SET SCREW
Step 12) Install scalp
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.6
Step 1) Install strike with shorter (3/4”) mounting screws
Step 2) Insert mortise lock into door and hand tighten longer (1”) mounting screws
R & L ESCUTCHEON:
MAKE SURE LOCK IS UNLOCKED
NOTE: Repeat step 3 & 4 for I/S Escutcheon
Step 5) Install O/S trim assembly
4
6
Spindles
Keypad ribbon cable
Outsideof Door
Installation of Outside Escutcheon
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain the lever spindle is properly engaged in lock. (see diagram and Note A. below) Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.) the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody screws. Remove Allen wrench.
Installation Instructions
Groundwire
Gasket (optional)
C A U T I O NDOOR MUST REMAIN OPEN
DURING INSTALLATION.USE DOOR STOP.
NOTE: Key and cylinder must be rotated as shown
Correct Incorrect
Use Correct Spindle Orientation
STANDARD MUSÉO
GASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces.
NOTE A.For MUSÉO Lever collections ONLY.Rotate adapter bushing as neededto insure horizontal lever position and maximum thread engaging lever - adapter bushing.
LeverLever
GOODBAD
Step 3) Thread hub into lever and fully tighten
Step 4) Align hub with square hole in lever; keeping hub as tight as possible
Hub
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.7
Align Turn-Piece Vertically
Step 6) Install I/S Escutcheon
CYLINDER SET SCREW
Step 7) Install Cylinder
4
6
Spindles
Keypad ribbon cable
Outsideof Door
Installation of Outside Escutcheon
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain the lever spindle is properly engaged in lock. (see diagram and Note A. below) Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.) the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody screws. Remove Allen wrench.
Installation Instructions
Groundwire
Gasket (optional)
C A U T I O NDOOR MUST REMAIN OPEN
DURING INSTALLATION.USE DOOR STOP.
NOTE: Key and cylinder must be rotated as shown
Correct Incorrect
Use Correct Spindle Orientation
STANDARD MUSÉO
GASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces.
NOTE A.For MUSÉO Lever collections ONLY.Rotate adapter bushing as neededto insure horizontal lever position and maximum thread engaging lever - adapter bushing.
LeverLever
GOODBAD
4
6
Spindles
Keypad ribbon cable
Outsideof Door
Installation of Outside Escutcheon
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain the lever spindle is properly engaged in lock. (see diagram and Note A. below) Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.) the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody screws. Remove Allen wrench.
Installation Instructions
Groundwire
Gasket (optional)
C A U T I O NDOOR MUST REMAIN OPEN
DURING INSTALLATION.USE DOOR STOP.
NOTE: Key and cylinder must be rotated as shown
Correct Incorrect
Use Correct Spindle Orientation
STANDARD MUSÉO
GASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces.
NOTE A.For MUSÉO Lever collections ONLY.Rotate adapter bushing as neededto insure horizontal lever position and maximum thread engaging lever - adapter bushing.
LeverLever
AFTER INSTALLING CYLINDER FULLY TIGHTEN LOCK MOUNTING SCREWS
Step 8) Install Scalp
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.8
HALF WORKING TRIM INSTALLATION
Step 1) Install strike with shorter (3/4”) mounting screws
Step 2) Insert mortise lock into door and hand tighten longer (1”) mounting screws
MAKE SURE LOCK IS UNLOCKED
SECTIONAL:
Align studs on rose with bushings in adapter plate
4
6
Spindles
Keypad ribbon cable
Outsideof Door
Installation of Outside Escutcheon
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain the lever spindle is properly engaged in lock. (see diagram and Note A. below) Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.) the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody screws. Remove Allen wrench.
Installation Instructions
Groundwire
Gasket (optional)
C A U T I O NDOOR MUST REMAIN OPEN
DURING INSTALLATION.USE DOOR STOP.
NOTE: Key and cylinder must be rotated as shown
Correct Incorrect
Use Correct Spindle Orientation
STANDARD MUSÉO
GASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces.
NOTE A.For MUSÉO Lever collections ONLY.Rotate adapter bushing as neededto insure horizontal lever position and maximum thread engaging lever - adapter bushing.
LeverLever
GOODBAD
Step 3) Install I/S adapter plate Step 4) Install spindle and rose
Step 5) Install I/S lever with set screw
Half trim adapter plate must be on non-trim side of the lockbody
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.9
4
6
Spindles
Keypad ribbon cable
Outsideof Door
Installation of Outside Escutcheon
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain the lever spindle is properly engaged in lock. (see diagram and Note A. below) Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.) the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody screws. Remove Allen wrench.
Installation Instructions
Groundwire
Gasket (optional)
C A U T I O NDOOR MUST REMAIN OPEN
DURING INSTALLATION.USE DOOR STOP.
NOTE: Key and cylinder must be rotated as shown
Correct Incorrect
Use Correct Spindle Orientation
STANDARD MUSÉO
GASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces.
NOTE A.For MUSÉO Lever collections ONLY.Rotate adapter bushing as neededto insure horizontal lever position and maximum thread engaging lever - adapter bushing.
LeverLever
Step 6) Install cylinder and secure with set screw
Slightly retract key to help thread cylinder into lock-body
AFTER INSTALLING CYLINDER FULLY TIGHTEN LOCK MOUNTING SCREWS
CYLINDER SET SCREW
Step 7) Mark turn-piece mounting holes and drill two .110” (BIT #35) holes where marked
Step 8) Mount turn-pieceStep 9) Install scalp
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.10
R & L ESCUTCHEON:Step 1) Install strike with shorter (3/4”) mounting screws
Step 2) Insert mortise lock into door and hand tighten longer (1”) mounting screws
MAKE SURE LOCK IS UNLOCKED
Step 5) Install I/S Escutcheon
4
6
Spindles
Keypad ribbon cable
Outsideof Door
Installation of Outside Escutcheon
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain the lever spindle is properly engaged in lock. (see diagram and Note A. below) Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.) the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody screws. Remove Allen wrench.
Installation Instructions
Groundwire
Gasket (optional)
C A U T I O NDOOR MUST REMAIN OPEN
DURING INSTALLATION.USE DOOR STOP.
NOTE: Key and cylinder must be rotated as shown
Correct Incorrect
Use Correct Spindle Orientation
STANDARD MUSÉO
GASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces.
NOTE A.For MUSÉO Lever collections ONLY.Rotate adapter bushing as neededto insure horizontal lever position and maximum thread engaging lever - adapter bushing.
LeverLever
GOODBAD
Align Turn-Piece Vertically
Step 3) Thread hub into lever and fully tighten
Step 4) Align hub with square hole in lever; keeping hub as tight as possible
Hub
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.11
4
6
Spindles
Keypad ribbon cable
Outsideof Door
Installation of Outside Escutcheon
2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon through the fire stop plate.
2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon through weather seal gasket (if used), then conduit sleeve in door (not shown).
3. With outside lever horizontal, insert mounting posts into the door. Make certain the lever spindle is properly engaged in lock. (see diagram and Note A. below) Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.) the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody screws. Remove Allen wrench.
Installation Instructions
Groundwire
Gasket (optional)
C A U T I O NDOOR MUST REMAIN OPEN
DURING INSTALLATION.USE DOOR STOP.
NOTE: Key and cylinder must be rotated as shown
Correct Incorrect
Use Correct Spindle Orientation
STANDARD MUSÉO
GASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.
1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces.
NOTE A.For MUSÉO Lever collections ONLY.Rotate adapter bushing as neededto insure horizontal lever position and maximum thread engaging lever - adapter bushing.
LeverLever
Step 6) Install cylinder and secure with set screw
Slightly retract key to help thread cylinder into lock-body
AFTER INSTALLING CYLINDER FULLY TIGHTEN LOCK MOUNTING SCREWS
CYLINDER SET SCREW
Step 7) Install scalp
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.12
FULL DUMMY TRIM INSTALLATION
SECTIONAL:
Step 1) Install O/S adapter plate Step 2) Install I/S adapter plate
Step 3) Install rose onto both adapter plates
Align studs on rose with bushings in adapter plate
Step 4) Install both levers with set screw
INSTALLATION INSTRUCTIONS
MUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.13
R & L ESCUTCHEON:
Step 3) Install O/S Escutcheon Step 4) Install I/S Escutcheon
Step 1) Insert spindle into hub and rotate lever CW until tight
Step 2) Push spindle into lever
NOTE: Repeat step 1 & 2 for I/S Escutcheon
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.14
HALF DUMMY TRIM INSTALLATIONSECTIONAL:
Step 1) Install adapter platePlastic bushings in
adapter plate go on top
Step 2) Install mounting screws and washers
Step 3) Install rose onto adapter plate
Step 4) Install lever with set screw
Align studs on rose with bushings in adapter plate
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.15
R & L ESCUTCHEON:
NOTE: Re-hand the lever, if necessary, by pushing spindle out of dummy plate and rotating lever
Step 1) Hold O/S escutcheon on door Step 2) Install mounting screws and washers
INSTALLATION INSTRUCTIONSMUSEO Trim InstructionsFM 601 Rev. C (04/13) (617418015)
Copyright © 2013 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.16
SECONDARY TRIM INSTALLATION
EMERGENCY KEY PLATE:Step 1) Mark emergency key mounting holes and drill two .110” (BIT #35) holes where marked
Step 2) Mount emergency key plate
In US: Corbin Russwin, Inc.225 Episcopal Road
Berlin, CT 06037-4004www.corbinrusswin.com
Technical Product Support:Phone: 888-607-5703 Fax: 800-659-7293
In Canada: ASSA ABLOY Door Security Solutions Canada
160 Four Valley DriveVaughan, ON, L4K 4T9
www.assaabloy.ca